| HS Code | 267465 |
| Product Name | Adfil Fibrin 660F - Synthetic Micro Fibrillated Fibers, 12mm |
| Manufacturer | Adfil |
| Material | 100% virgin polypropylene |
| Fiber Type | Synthetic micro fibrillated |
| Fiber Length | 12 mm |
| Specific Gravity | 0.91 |
| Fiber Count | 660 million fibers per kg |
| Tensile Strength | 350 MPa |
| Young S Modulus | 3500 MPa |
| Melting Point | 160 °C |
| Ignition Point | 360 °C |
| Alkali Resistance | Excellent |
| Acid Resistance | Excellent |
| Water Absorption | Nil |
| Typical Dosage | 0.9 kg/m³ |
| Packaging | 0.6 kg bags |
| Color | Natural |
As an accredited Adfil Fibrin 660F - Synthetic Micro Fibrillated Fibers, 12mm factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 20 kg moisture-resistant paper bags, palletized and shrink-wrapped for safe transport and dry storage. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): Adfil Fibrin 660F, 12mm synthetic micro fibrillated fibers, palletized bags, dry, stable stowage, secure, full container. |
| Shipping | Adfil Fibrin 660F is shipped as non-hazardous synthetic micro fibrillated fibers, 12 mm, in sealed moisture-resistant bags packed on pallets and shrink-wrapped. Cartons are labeled with product name, batch, quantity, and handling instructions. Transport in clean, dry vehicles at ambient temperature, protecting from moisture, contamination, and physical damage. |
| Storage | Store Adfil Fibrin 660F in original, sealed packaging in a clean, dry, well-ventilated area. Keep away from moisture, direct sunlight, heat, ignition sources, and incompatible materials. Place on pallets off the floor, avoid excessive stacking, and protect bags from punctures or tearing. Handle gently to minimize dust. Rotate stock using first-in, first-out. Use appropriate PPE when handling. |
| Shelf Life | 24 months from date of manufacture when stored in dry conditions, original unopened packaging, at 5–25°C, protected from direct sunlight. |
Addition of Adfil Fibrin 660F to a conventional ready-mixed concrete at a dosage of 0.9 kg/m³ modifies the plastic-state settlement and bleed-water transport behaviour on slab-on-ground and suspended slab pours. The fiber is a micro-fibrillated polypropylene tape with a nominal cut length of 12 mm, which opens into a network of fibrils under normal compulsory mixing. This network increases the fine-particle surface area within the mortar fraction, reduces the rate of bleed water travelling through capillary channels, and interferes with the coalescence of plastic shrinkage cracks in the first 4–8 h after strike-off. In production, the fiber is added through the plant aggregate weigh hopper or a fibre batching unit after the coarse aggregate and sand are charged, before the cementitious binder and mixing water. The sequence prevents hydrophobic fiber clustering on wet aggregate surfaces. A twin-shaft compulsory mixer with full-speed mixing for at least 60 s after fiber introduction gives acceptable dispersion; truck drum mixing alone after wet batch discharge is not acceptable as the sole dispersion mechanism because aged drum fins and low-speed rotation do not generate sufficient shear to separate the micro-fibrillar bundles. The addition typically lowers slump measured under EN 12350-2 from a control value of 180 mm to 150–160 mm at the same water-cement ratio. When field placing requires the original workability, a polycarboxylate superplasticizer complying with EN 934-2 should be added, rather than increasing batch water because a higher water-cement ratio would compromise cured surface abrasion resistance and increase capillary porosity. In slabs, the function of the micro-fibrillated fiber is not to replace structural reinforcement or to increase post-crack flexural capacity; the fiber is a plastic-state additive for crack-width control and bleed reduction. Evaluation under ASTM C1579-21 on a constrained slab panel can be used to compare plastic shrinkage crack area against an unreinforced control mix; published data for this specific configuration is limited, so project-specific comparative testing is required before a performance specification is fixed. Terminal uses include residential slab-on-grade, multi-storey suspended slab soffits, parking decks, and industrial floor slabs where early finishing and steel trowelling generate surface evaporation rates above 0.5 kg/m²/h and elevate plastic cracking risk. If the relative humidity at the pour site is below 40% or the wind speed above 5 m/s, evaporation control under ACI 305R should remain the primary measure; fiber addition alone does not override inadequate curing. Dosages above 1.8 kg/m³ in conventional ready-mixed concrete can produce visible fiber clumping at the surface after power trowelling, particularly when using high-speed ride-on trowels with pan blades set at aggressive pitch.
| Standard or code | Requirement or test method | Relevance for 12 mm micro-fibrillated fiber |
|---|---|---|
| EN 14889-2:2006 | Polymer fibers for concrete, Class I | CE marking under CPR 305/2011; verifies geometry, tensile strength, alkali resistance |
| ASTM C1116/C1116M-10a | Type III synthetic fiber-reinforced concrete | Basis for specification in North American concrete and shotcrete |
| ASTM C1579-21 | Plastic shrinkage cracking of restrained concrete panel | Comparative crack area measurement for fiber dosage validation |
| EN 12350-2:2019 | Slump test for fresh concrete | Workability adjustment after fiber addition |
| EC 1907/2006 | REACH polymer registration exemption; monomer residues subject to registration | Supply documentation for EU import and downstream use |
| ISO 9001:2015 | Quality management system for fiber manufacturing | Batch traceability and dimensional tolerance control |
Thin-wall precast concrete enclosure panels with thickness from 70 mm to 120 mm are sensitive to cracking during demoulding, tilting, and transport because the green concrete carries its own mass through a narrow cross-section before full hardening. In such mixes the micro-fibrillated polypropylene fiber is batched at 0.9–1.2 kg/m³ depending on the maximum aggregate size, which is usually 8 mm to 10 mm, and the cement content, which typically ranges from 380 kg/m³ to 420 kg/m³. The fiber is charged into a planetary or turbo compulsory mixer after the dry aggregates and before the first water addition; mixing continues for 90–120 s total. A critical production failure occurs when the high-range water reducer is injected before the fiber has dispersed, because the polymer chains of the superplasticizer and the hydrophobic fiber surface form low-water agglomerates that remain as fibrous nests on the panel face. The panel is compacted on a vibrating table operating at 40–60 Hz for 45–90 s, followed by a surface trowelling pass with a damp steel trowel; the fibrillated network raises green tensile strength sufficiently to reduce edge breakout at demoulding, but it does not function as a macro-synthetic reinforcement for lifting stresses. Compliance for precast elements is defined under EN 13369 common rules for precast concrete products, with the fiber itself covered by EN 14889-2. When severe fire exposure is specified, the fiber dosage may be increased toward 1.5–2.0 kg/m³ because polypropylene melting between 160 °C and 170 °C forms pressure-relief channels during fire-induced spalling; however, this upper dosage must be tested under the relevant fire curve because the mix workability and surface finish are affected. Terminal products include architectural spandrel panels, solid boundary wall panels, transformer enclosure walls, and utility chamber covers. Structural design must still allocate tensile forces to steel reinforcing bars or prestressing strands; the micro-fibrillated fiber does not contribute to characteristic flexural strength under EN 1992-1-1 or ACI 318-19 and is therefore excluded from conventional reinforced-concrete section capacity calculations unless a performance-based test program demonstrates otherwise under EN 14651 or ASTM C1609.
In dry-mix shotcrete production for structural and non-structural concrete repair, Adfil Fibrin 660F is metered into the pre-bagged dry blend at 0.1–0.3% by dry mortar mass, corresponding to roughly 1–3 kg per tonne of repair mortar. The fiber length of 12 mm is selected to remain below the typical nozzle restriction of 25–32 mm and to reduce the occurrence of blockages when sprayed material is conveyed through a rotor/stator spray machine. Dry blending is carried out in a horizontal twin-shaft or ribbon mixer with a fill level not exceeding 70% of gross volume; a mixing time of 3–5 min at low speed is required to distribute the fibrillated fiber without generating the electrostatic charge that separates the micro-fibrils from the mineral fines. High-shear pin mixers should be avoided because the rotating pin tools can wrap the fibrillated bundles into tight nests that survive dry conveying and appear as visible inclusions in the sprayed layers. At the nozzle, compressed air pressure between 0.4 MPa and 0.6 MPa and a nozzle distance of 0.5–1.0 m from the substrate provide acceptable compaction; the fiber tends to reduce early rebound of the coarse fraction, but the rebound reduction is mix-dependent and should be measured on a trial panel before a production specification is fixed. The hardened repair mortar is specified under EN 1504-3 class R3 or R4 for structural and non-structural repair; sprayed concrete quality is evaluated under EN 14488-1 for compressive strength and EN 14488-2 for energy absorption when relevant. The micro-fibrillated fiber is not a substitute for welded wire mesh or macro-synthetic fibers in structural shotcrete linings where post-crack energy absorption is required; for that function a macro-synthetic fiber with a length of 30–60 mm and a diameter above 0.3 mm is normally specified under EN 14889-2 Class II. Terminal uses include hand-applied repair mortars, dry-process shotcrete for tunnel repair, slope protection, swimming pool shell repair, and architectural rockwork where crack control between substrate and overlay is required. The maximum aggregate size should be kept at 10 mm or below to prevent fiber and aggregate interlock in the spray hose; if aggregate larger than 10 mm is unavoidable, the fiber dosage should be moved to the lower end of the range.
Cementitious flowing or semi-dry screeds installed over underfloor heating pipes face differential drying shrinkage above the heated pipes, because the local temperature and moisture gradients promote early-age microcracking around the pipe crown. In this application, Adfil Fibrin 660F is dosed at 0.6–1.0 kg/m³ for pump-applied flowing screeds and up to 1.2 kg/m³ for semi-dry screeds that are compacted with a roller screed. The fiber is blended into the dry batch at the silo mixing station before the water content is set to achieve a flow spread of 260–300 mm under EN 12706 for flowing screeds. Because the fiber increases the yield stress of the fine mortar, the same flow class requires a slight increase in polycarboxylate superplasticizer dosage rather than an increase in water; adding water to restore flow would lower the compressive class and increase drying shrinkage, which is counterproductive in heated screeds. The hardened screed is specified under EN 13813:2002 with the designation CT-C30-F5 for flowing cement screeds, where the fiber is considered an additive and not a replacement for the standard mesh or mat reinforcement required by local floor design codes. During the heating cycle after 28 days, the fiber network does not reduce the coefficient of thermal expansion of the cement paste, but it limits the visible crack width that develops where thermal movement is restrained at door thresholds, floor drains, and column penetrations. Field failures observed in pumped screed lines include fiber accumulation at hose couplings when the fiber is added directly to the ready-mixed screed truck without pre-mixing; therefore, the fiber should be introduced through the dry aggregate stream at the batching plant and not into the pump hopper. Terminal floor products include monolithic residential screeds, commercial office raised-floor infill, industrial warehouse overlays, and underfloor heating screeds. The operating boundary for this use is that the fiber does not permit elimination of movement joints prescribed under BS 8204-1 or project specifications based on EN 13813, and crack control at restrained perimeters still depends on joint layout and curing. Overdosing above 1.5 kg/m³ in a flowing screed can produce visible fiber lift on the trowelled surface and should be avoided unless a test panel confirms acceptable surface appearance under the specified power trowel regime.
Gypsum plaster formulations containing the 12 mm micro-fibrillated fiber at 0.05–0.2% by dry mass are used in spray-applied fire protection plasters and manual interior wall renders. The fiber functions differently from its role in cementitious systems because gypsum paste has lower alkalinity and faster setting; the primary benefit is the reduction of surface tearing during the transition from plastic to set state and the improvement of green edge strength at reveals and window returns. The fiber is dry-blended with hemihydrate gypsum and lightweight aggregate in a continuous mixer or low-shear conical screw mixer at a fill level below 65%; using a high-speed disperser above 400 rpm can strip the fibrils from the parent tape and produce a fuzzy, difficult-to-trowel surface. Spray application is performed with a worm-pump plaster machine at air pressure 0.3–0.5 MPa; manual application uses a stainless steel trowel. The fiber addition does not increase the compressive strength of gypsum board cores and is not specified as a reinforcing fiber under EN 13279-1:2008 for gypsum binders and gypsum plasters. Terminal uses include interior plaster finishes, fire-protection plaster around structural steel, and board jointing compounds where a short fibrillated fiber reduces mud-cracking at high water demand. The dosage boundary is 0.3% by dry mass; above this level, trowel drag increases and sanding of the dried surface becomes more difficult. Published data for this specific configuration is limited, so a plant trial with a 1 m² test panel is required before film-thickness specifications are finalised.
Zero-slump concrete used in segmental paving and retaining block machines requires sufficient green strength to survive immediate demoulding, stacking, and strapping without edge damage. Adfil Fibrin 660F is added at 0.1–0.2% by mass of the dry concrete, approximately 0.9 kg/m³ for a dense zero-slump mix, and is mixed in a paddle mixer for 45–60 s dry before the water and pigment dispersion are introduced. The low water-cement ratio, typically 0.30–0.38, means the fibrillated fiber must be dispersed by aggregate-to-aggregate shear rather than by fluid suspension; therefore, fiber addition to the wet mix after compaction begins is ineffective and leads to surface tufting. The mix is compacted on a vibration press with a frequency range of 50–70 Hz and variable compaction force depending on the block height; the fiber network does not alter the required compaction energy but reduces edge breakout when the product is pushed from the steel mould to the production board. Paving units are specified under EN 1338:2003 for concrete paving blocks, EN 1339:2003 for paving flags, EN 1340:2003 for kerbs, and ASTM C936/C936M-22 for solid concrete interlocking paving units in North America. The fiber does not contribute to flexural strength or freeze-thaw resistance directly; freeze-thaw performance is governed by the air-void system and water absorption limits in the product standard, not by fiber addition. Terminal products include interlocking pavers, permeable paving units, retaining wall blocks, and kerb units. The operational boundary is that the fiber must not be used to reduce the minimum thickness required by product standards, and mix designs with cement contents below 280 kg/m³ may show insufficient paste to bury the fibrillated fiber, leaving visible surface fuzz after weathering.
Competitive Adfil Fibrin 660F - Synthetic Micro Fibrillated Fibers, 12mm prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Adfil Fibrin 660F is supplied as a synthetic micro fibrillated fibre with a nominal cut length of 12 mm. The product is categorised as a Type III synthetic fibre under ASTM C1116/C1116M and is intended for non-structural crack control in concrete, mortar, and screed. Addition is performed in the fresh state to intercept plastic shrinkage microcracking before setting; the fibre is not a substitute for structural steel reinforcement where post-crack residual flexural capacity is required. Mechanical and chemical data are generated under fibre-class test methods, and lot-specific values should be verified against the current manufacturer technical data sheet.
Adfil Fibrin 660F is produced from a virgin polypropylene homopolymer. The polymer exhibits a melt peak of 160 °C to 165 °C when measured by differential scanning calorimetry in accordance with ISO 11357-3, and a density of 0.91 g/cm³ under ISO 1183-1. Moisture regain is below 0.1% after 24 h immersion in distilled water at 23 °C when evaluated by the procedural principles of ISO 62; the fibre therefore introduces no chemically bound mixing water demand. Nominal tensile properties fall in the range of 300–400 MPa tensile strength and 3.5–4.0 GPa tensile modulus when tested on the tape in accordance with ISO 2062 or ASTM D2256. Elongation at break is normally 15–25%. The fibrillated tape structure exposes a high surface area per unit mass, which influences both paste absorption behaviour and mechanical interlock. Alkali resistance is inherent to polypropylene but should be confirmed for cementitious environments containing pH values above 13.0 by means of a project-specific immersion protocol. Lot-specific values may vary within raw-material tolerances; the current product data sheet is the controlling document for release limits.
The 12 mm designation refers to the longitudinal cut length after fibrillation; the individual tape segments split during mixing into an irregular network with an equivalent diameter that is not single-valued. Bulk density of the packaged fibre is approximately 0.90 g/cm³ to 0.92 g/cm³ but is not a specification for concrete proportioning; dosing is calculated by mass per cubic metre. Packaging is commonly supplied as dispersible paper bags designed for direct addition to a truck mixer or batch plant. The bag material must be confirmed as dispersing in the mixer; poly-lined or moisture-resistant constructions should not be introduced without plant validation. Fibre count per kilogram is determined by tape denier and fibril geometry and should be recorded from the batch certificate; field dosing is verified by weight rather than by count.
Fibre length controls both dispersion efficiency and the risk of balling in low-slump concrete. At 12 mm, the fibrillated tape is short enough to pass through standard pump lines and finishing tools, but long enough to bridge plastic shrinkage microcracks before setting. In central-mix equipment with twin-shaft compulsory mixers, the fibre is introduced after aggregate and cement charging and before the final fraction of batch water. A wet mixing interval of 70–90 seconds at 18–22 rpm is normally sufficient to separate individual tapes; reducing this interval below 60 seconds has been associated with visible fibre agglomerates in 3 m³ field trials. In truck-mix deliveries, the bags are charged into the drum at mixing speed, followed by 4–5 minutes at 12–15 rpm. Extended mixing beyond 8 minutes can increase electrostatic charge accumulation on the polymer surface and should be avoided unless a dispersing agent or antistatic addition is explicitly qualified. For dry-bag addition, the batch plant operator must confirm that the bag charges are not blocked by aggregate hang-up or headwater seals.
Batch acceptance is verified by taking a fresh concrete sample and washing it over a 4.75 mm sieve to inspect fibre distribution. A uniform separation without matted bundles is the practical release criterion; any agglomerated fibre mass retained on the sieve after a 1-minute wash should trigger a mixing-time or charging-rate adjustment. Slump loss attributable to the fibre at dosages of 0.6 kg/m³ to 1.0 kg/m³ is generally less than 10 mm in mixes with initial slumps of 100–150 mm, but this must be verified for each cement-admixture combination. No water compensation for fibre addition is permitted unless the admixture supplier has measured the change in water demand under the project mix design. A concrete rheometer or falling-ball viscometer used on the project mix will record paste viscosity shifts that are not captured by slump alone; if plastic viscosity increases beyond the pump manufacturer’s published limit, the mix should be reformulated rather than overdosing water or high-range water reducer.
Plastic shrinkage cracking is governed by the rate of bleed-water evaporation relative to bleed-water supply at the surface. In slab placements exposed to wind speeds above 4.0 m/s, low relative humidity below 40%, or concrete temperatures above 30 °C, the capillary pressure in the plastic paste can exceed its low tensile strength. Fibrillated micro fibres provide restraint by bridging incipient cracks across the top 25–50 mm of the slab. The mechanism is physical: the fibrillated network increases the apparent fracture energy of the fresh paste without altering the hydration chemistry. Evaluation under ASTM C1579 is applicable for comparative plastic shrinkage performance. That method imposes a severe evaporation regime with a concrete surface temperature of 36 ± 3 °C, relative humidity of 30 ± 5%, and air flow of 5.0 ± 0.5 m/s over a restrained panel with a central stress riser. Published data for this specific configuration are limited, and project-specific testing is required to attribute a numeric crack reduction factor to a given mix. Dosage trials are typically conducted at 0.6 kg/m³, 0.9 kg/m³, and 1.2 kg/m³ because response is nonlinear and depends on cement content, fines, and finishing interval. If bleeding rate under ASTM C232 is reduced, the observed surface moisture may alter the timing of floating and trowelling; this is a production parameter rather than a material defect.
The hydrophobic fibre surface can interact with air-entraining admixtures in mixes requiring frost resistance. In trial batches with a vinsol-resin or synthetic surfactant air-entraining agent, total air content under ASTM C231/C231M may shift by 0.3–0.5% when fibre dosage changes from 0 to 1.2 kg/m³. The spacing factor measured under ASTM C457/C457M should be maintained below 0.20 mm for freeze-thaw resistance; fibre interference with the air-void system must be assessed on the project mix because paste viscosity increase can reduce bubble coalescence but can also entrap larger voids. The standard production practice is to hold the air-entraining agent dosage constant, add the fibre, and measure air content before any admixture adjustment is made. No air-entraining agent adjustment based solely on a fibre addition curve is acceptable without fresh and hardened air-void data.
The defining difference between Adfil Fibrin 660F and a circular monofilament micro fibre is the fibrillated cross-section. Fibrillation increases surface area per unit mass and creates a branched network that anchors more effectively in cement paste, but it also increases mixing-energy demand and can produce greater finishability changes if overdosed. Steel fibres with diameters of 0.5–1.0 mm and lengths of 30–60 mm operate in the hardened state to provide post-crack residual flexural strength under ASTM C1609/C1609M or EN 14651; the 12 mm fibrillated micro fibre does not produce the same post-crack load transfer because its low elastic modulus and short length place it below the structural threshold. Cellulose fibres are hydrophilic and can bind water at the surface, whereas polypropylene is hydrophobic and does not chemically alter the water-cement ratio. Macro-synthetic fibres of 38–54 mm length and 0.5–1.0 mm equivalent diameter are used for temperature-shrinkage and post-crack applications; the micro fibrillated product is confined to early-age crack control and minor thermal restraint applications. Use of Adfil Fibrin 660F alongside steel fibres is possible when early-age cracking and hardened post-crack capacity are both required, but the combined system must be tested in the project mix because fibre-fibre interference can reduce dispersion if charging rates are uncontrolled.
| Fibre class | Typical length range | Primary test method | Functional difference in concrete |
|---|---|---|---|
| Fibrillated micro polypropylene (Adfil Fibrin 660F) | 12 mm | ASTM C1579 plastic shrinkage | High surface network for early-age crack control; no structural post-crack capacity |
| Monofilament polypropylene micro fibre | 6–20 mm | ASTM C1579 | Lower surface area; reduced mixing-energy demand and easier finishing |
| Steel hooked-end fibre | 30–60 mm | EN 14651, ASTM C1609/C1609M | High modulus; provides post-crack flexural resistance; potential corrosion at cracks |
| Cellulose micro fibre | 1–3 mm | ASTM C1579 | Hydrophilic; increases water demand; modifies bleed and drying characteristics |
| Macro-synthetic fibrillated or embossed fibre | 38–54 mm | EN 14651, ASTM C1609/C1609M | Post-crack and temperature-shrinkage control; higher addition rates required |
Hardened-density, compressive-strength, and modulus-of-elasticity values are not the primary design variables for this fibre. In standard concrete at dosages up to 1.0 kg/m³, compressive strength change is typically within normal batch-to-batch scatter when identical mix design and curing are used. The fibre reduces free plastic settlement; this can reduce surface bleed and alter finishing timing. Finishers often observe that a micro fibrillated fibre at 0.9 kg/m³ requires a slightly earlier or more aggressive float pass because surface texture is influenced by tape segments reorienting under the trowel. The product is not a pumpability aid; although the 12 mm length generally passes through 50 mm to 125 mm concrete pump hoses, the actual maximum pumping distance should be verified with the concrete producer and pump type. For vertical slipform or sprayed applications, the fibre is not automatically suitable; only test panels can establish that the fibrillated tape does not impair compaction or interface bonding.
The product is subject to conformity documentation under EN 14889-2 for polymer fibres for concrete when placed on the European market. For the United States, fibre designation follows ASTM C1116/C1116M Type III synthetic fibre requirements. Batch release records should include cut length distribution, fibril separation quality, fibre count per gram, and packaging integrity. The matrix below summarises the typical compliance file; because regulatory scopes change, the current manufacturer certificate is the controlling document.
| Standard / Regulation | Scope | Typical status for Adfil Fibrin 660F |
|---|---|---|
| EN 14889-2 | Polymer fibres for concrete: definitions, specifications, conformity | Declared by manufacturer |
| ASTM C1116/C1116M | Standard specification for fibre-reinforced concrete | Type III synthetic fibre classification |
| ASTM C1579 | Plastic shrinkage cracking of restrained fibre-reinforced concrete | Suitable test method for evaluation |
| ISO 9001 | Quality management system and batch traceability | Manufacturer certification |
| REACH EC 1907/2006 | Substance registration and SVHC restrictions | Declared compliance |
| RoHS 2011/65/EU | Hazardous substances in electrical and electronic equipment | Not in scope for concrete fibre |
| FDA 21 CFR 177.1520 | Olefin polymers in food-contact articles | Confirm applicability for potable-water contact |
Storage should avoid direct UV exposure for extended periods because polypropylene undergoes photo-oxidative degradation under continuous sunlight. Shrink-wrap or opaque packaging maintains cut-length integrity and fibril separation; the product should be kept below 40 °C and away from strong oxidising agents. Addition to concrete containing air-entraining admixtures may change the measured air content by up to 0.5% at high dosage; trial batching under ASTM C231/C231M is required before production. Incompatibility with hydrocarbon-based curing compounds is not expected, but solvent-based products should be tested for surface wetting if sprayed immediately after finishing. The fibre should not be used as a replacement for structural reinforcement or as a means of controlling cracks where width limits below 0.2 mm are specified for structural members under load. If sustained exposure to diesel, gasoline, or ketone-based solvents is possible during construction, a small immersion test should be performed because aromatic and chlorinated solvents can soften or swell the fibre surface.