| HS Code | 783477 |
| Productname | Adfil Sinta F (SINTA F) - Fibrillated Polypropylene Fiber |
| Material | 100% virgin polypropylene |
| Fibertype | Fibrillated |
| Fiberlength | 12 mm |
| Equivalentdiameter | 0.032 mm |
| Aspectratio | 375 |
| Density | 0.91 g/cm³ |
| Tensilestrength | 350 MPa |
| Elasticmodulus | 3500 MPa |
| Meltingpoint | 165 °C |
| Ignitionpoint | 360 °C |
| Alkaliresistance | Excellent |
| Acidresistance | Excellent |
| Waterabsorption | Nil |
| Thermalconductivity | Low |
| Electricalconductivity | Low |
| Typicaldosage | 0.9 kg/m³ |
| Colour | Natural |
As an accredited Adfil Sinta F (SINTA F) - Fibrillated Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Adfil Sinta F is supplied in 20 kg moisture-resistant paper sacks, palletized and shrink-wrapped for convenient storage and handling. |
| Container Loading (20′ FCL) | Loaded in 20′ FCL: palletized bags of Adfil Sinta F fibrillated polypropylene fiber; dry, non-hazardous, ambient cargo, securely stowed for shipment. |
| Shipping | Adfil Sinta F (SINTA F) Fibrillated Polypropylene Fiber is non-hazardous and not classified for transport. Ship in original sealed bags or cartons, palletized and shrink-wrapped. Protect from moisture, direct sunlight, and physical damage. No special handling required; store dry at ambient temperature. Normal freight, road, sea, or air. |
| Storage | Store Adfil Sinta F (SINTA F) fibrillated polypropylene fiber in a cool, dry, well-ventilated warehouse away from direct sunlight, heat, sparks, and open flames. Keep original bags tightly closed, off the ground on pallets, protected from moisture, oils, and incompatible chemicals. Avoid prolonged UV exposure. Use first-in, first-out rotation. Maintain good housekeeping and avoid excessive stacking to prevent bag damage. |
| Shelf Life | Store dry, in original unopened packaging, away from direct sunlight; shelf life approximately 12 months under recommended conditions. |
In precast concrete manufacturing, 0.9 kg/m3 to 2.0 kg/m3 of SINTA F is introduced at the aggregate weigh hopper or on the collecting conveyor before cement slurry addition. In dry-cast pipe and manhole mixes with water-cement ratios between 0.30 and 0.38, the fibrillated network disperses during a 60 s to 120 s pan-mixer cycle and remains anchored across the narrow paste bridge between coarse aggregate particles. The fibre itself is specified under EN 14889-2:2006 for polymer fibres, while the finished precast elements fall under EN 1916:2002 for concrete pipes, EN 1917:2002/A1:2008 for manholes, and ASTM C478-22 for circular precast reinforced concrete manhole sections. Vertical vibration or rollerhead compaction followed by immediate demoulding exposes green concrete edges, spigot ends, and lifting sockets to chipping; the fibrillated polypropylene resists early crack opening during form stripping and yard stacking without replacing the primary reinforcing steel required by governing static design. Finished components include reinforced concrete sewer pipes, box culverts, jacking pipes, manhole riser sections, concentric and eccentric cones, and base slabs. Field experience from precast operators indicates fewer fibre balls when the material is fed to a moving aggregate conveyor rather than dumped directly into the pan mixer at full batch size.
Ground-supported industrial slab placements with side discharge mixers or central mix plants require a dosage of 1.8 kg/m3 to 2.7 kg/m3 when the slab is expected to carry rack leg point loads, narrow-aisle forklift traffic, or freezer bay duty before joint stabilisation. This addition range is evaluated under ASTM C1579-21 for restrained plastic shrinkage and is specified as part of a concrete floor system under ACI 302.1R-15. A high-range water reducer conforming to ASTM C494/C494M Type F is commonly required to offset the 15 mm to 40 mm slump loss measured under ASTM C143/C143M at the upper dosage. Laser-guided screed operations place panels of 4.5 m to 6.0 m width; power trowelling then closes the surface while the fibrillated fibres remain below the near-surface paste layer. Saw cutting of contraction joints follows within 6 h to 12 h at a depth of one-fourth the slab thickness unless early-entry saws are used. Terminal products include logistics warehouse floors, automotive assembly plant slabs, food processing floors, and low-temperature storage bays. The fibre reduces early-age cracking from evaporative water loss but does not substitute for load transfer devices at contraction joints, for slab reinforcement design, or for surface hardeners applied in high-abrasion zones.
| Downstream segment | Typical dosage range | Primary compliance framework | Production/process control point |
|---|---|---|---|
| Precast manholes, pipes, box culverts | 0.9–2.0 kg/m3 | EN 1916:2002, EN 1917:2002/A1:2008, ASTM C478-22 | Aggregate weigh hopper addition; 60–120 s pan mixing |
| Industrial ground-supported slabs | 1.8–2.7 kg/m3 | ACI 302.1R-15, ASTM C1579-21, ASTM C94/C94M | Laser screed placement; saw cut within 6–12 h |
| Dry-mix shotcrete linings | 4.5–9.0 kg/m3 | EN 14487-1:2005, ASTM C1550-20 | Nozzle air 5–7 bar; hose ID 50–65 mm; rebound 10–25% |
| Thin bonded overlays, repair mortars | 0.6–1.2 kg/m3 | EN 1504-3:2005, ASTM C928/C928M | Forced-action paddle mixer 3–5 min; hydrodemolition substrate prep |
| Septic tanks, buried vaults, effluent chambers | 1.0–1.8 kg/m3 | ASTM C1227/C1227M, EN 1917:2002/A1:2008, EN 12566-3 | External vibrators 20–30 s per lift; steam cure 60–70 °C for 16–20 h |
| Cementitious floor screeds | 0.4–0.9 kg/m3 | EN 13813, BS 8204-1 | Rotor-stator pump; oscillating screed bar; float finishing |
In dry-mix shotcrete linings, the dosage moves upward to 4.5 kg/m3 to 9.0 kg/m3 depending on the required energy absorption class and the thickness of the bonded liner. EN 14487-1:2005 governs sprayed concrete specification in the European framework, while ASTM C1550-20 round panel testing provides residual load and toughness values used to compare fibre performance under central point loading. The fibrillated tape geometry increases mechanical interlock across the nozzle stream and in the compressed layer, but it also raises the sensitivity of the dry-mix feed system; pre-dampened sand at 3% to 5% moisture reduces balling in the rotary gun. Air pressure at the nozzle typically ranges from 5 bar to 7 bar, with hose inner diameters of 50 mm to 65 mm; vertical wall rebound losses of 10% to 25% are observed on production faces and must be factored into material orders. The finished linings serve as temporary crown support in soft-ground tunnelling, permanent slope stabilization on cut faces, canal relining where mesh placement is impractical, and underground chamber linings subject to early hydration shrinkage. The fibre does not replace rock bolts, steel ribs, or welded wire mesh where structural tensile capacity and post-crack strength beyond the round panel classification are mandatory. Published data for this specific product configuration at the upper dosage in high-rebound overhead work is limited.
Bridge deck repair specifications that allow polymer-modified cementitious overlays in thicknesses between 25 mm and 50 mm specify SINTA F at 0.6 kg/m3 to 1.2 kg/m3, a lower range than slab-on-grade work because the fine aggregate matrix limits fibre mobility during trowelling. Compliance is checked against EN 1504-3:2005 for structural and non-structural repair products and ASTM C928/C928M for packaged dry concrete repair materials. Substrate preparation by hydrodemolition or captive shotblasting exposes a saturated surface-dry profile; the repair mortar is then mixed in a forced-action paddle mixer for total batch times of 3 min to 5 min, transferred by hopper, and placed with a screed rail. Overlay applications include bridge deck patches, parking garage ramp repairs, warehouse contraction joint rebuilds, and mat foundation surface restoration. The fibrillated fibres suppress early-age plastic shrinkage cracks in thin section but do not compensate for missing dowel action, excessive surface deflection, or inadequate substrate adhesion. When ambient temperature falls below 5 °C, batching trials should confirm fibre dispersion because increased paste viscosity can promote clumping in low-moisture repair mortars.
Vibrated wet-cast production of buried containment structures uses 1.0 kg/m3 to 1.8 kg/m3 of the fibrillated polypropylene fibre in concrete with a 35 MPa minimum 28-day compressive strength and a water-cement ratio below 0.45. Product compliance is defined by ASTM C1227/C1227M for precast concrete septic tanks, EN 1917:2002/A1:2008 for manholes, and EN 12566-3 for packaged wastewater treatment plants where tank geometry integrates the same precast shell. High-frequency external vibrators on steel moulds compact the fibre-bearing mix without driving the lighter polypropylene to the surface, provided vibration is timed at 20 s to 30 s per lift. Steam curing at 60 °C to 70 °C for 16 h to 20 h accelerates turnover and reduces form inventory pressure; vacuum testing of the demoulded tank under ASTM C1227/C1227M confirms watertightness independent of fibre content. Finished product categories include single-compartment septic tanks, pump chambers, grease interceptors, agricultural holding tanks, and cast-in-place monoliths for buried vaults. Fibre addition lowers visible crack incidence on tank walls during transport, lifting, and backfill but does not seal improperly consolidated concrete or compensate for missing wall reinforcing steel.
Cementitious floor screed mixes processed in horizontal shaft mixers and delivered by rotor-stator pump receive SINTA F at 0.4 kg/m3 to 0.9 kg/m3, a dosage optimised for fine sand fractions of 0 mm to 4 mm. The governing material standard is EN 13813 for screed material and in-situ floor screeds; placing and finishing recommendations follow BS 8204-1. After mixing, the fibrillated fibre disperses in the cement paste without the coarse aggregate collisions that generate surface fuzz in structural mixes. The wet screed is pumped through a 50 mm or 65 mm hose and struck level with an oscillating screed bar, then closed with a wooden float to avoid lifting polypropylene filaments into the wearing surface. Bonded screeds, unbonded screeds on separating membranes, floating screeds over insulation, and underfloor heating screeds represent the terminal products. At the upper dosage, pumping pressures may increase by 0.5 bar to 1.5 bar depending on hose length and pump type; this operational boundary requires pump calibration before full-scale placement.
Competitive Adfil Sinta F (SINTA F) - Fibrillated Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Adfil Sinta F (SINTA F) is a fibrillated polypropylene fibre supplied as a collated synthetic fibre for cementitious matrices. The product designation identifies the fibrillated film geometry rather than a monofilament, steel-fibre, or macro-synthetic structure. Under high-shear mixing, the collated bundles separate into a branched network of fine polypropylene fibrils that distribute through the fresh concrete. The polymer is a polypropylene homopolymer with a specific gravity reported by the manufacturer in the range of 0.90–0.92 g/cm³. Because the fibre is hydrophobic and resistant to alkaline pore solution, it does not corrode, does not absorb mixing water, and does not participate directly in cement hydration. The primary engineering function of SINTA F is control of plastic shrinkage cracking and plastic settlement cracking in slabs, overlays, precast units, and flatwork. It is not a substitute for structural steel reinforcement, deformed steel fibre, or macro-synthetic fibre intended to provide post-crack residual flexural performance.
The fibrillated structure is produced by extruding polypropylene film, orienting it longitudinally, and then slitting or embossing to create a lattice of interconnected fibrils. The resulting fibre has a non-circular cross-section and a higher surface area per unit mass than a solid monofilament of equivalent denier. Because fibrillation makes direct diameter measurement ambiguous, specification of this product is best made by cut length, dosage rate, and compliance with ASTM C1116/C1116M-15 Type III synthetic fibre requirements. Manufacturer-published data for SINTA F should be verified against the batch certificate. Representative values for the fibrillated polypropylene fibre class are summarised below.
| Property | Representative range or limit | Reference method |
|---|---|---|
| Specific gravity | 0.90–0.92 g/cm³ | ISO 1183-1:2019 / ASTM D792-20 |
| Melting temperature | 160–170 °C | ISO 11357-3:2018 |
| Water absorption | <0.1% by mass after 24 h | ASTM D570-22 |
| Tensile strength of drawn polypropylene film | 300–450 MPa | ISO 527-3:2018 |
| Elongation at break | 15–30% | ISO 527-3:2018 |
| Alkaline resistance | <1% mass change after 28 d in saturated Ca(OH)₂ at 20 °C | ASTM D543-20 adapted |
The cut length most frequently specified for slab-grade applications is 12 mm; alternative lengths may be produced by the manufacturer. Because fibrillation creates a non-circular and branched cross-section, equivalent diameter is not a reliably singular specification parameter. Published data for the exact number of individual fibrils per kilogram is limited, as the splitting ratio depends on mixing energy, aggregate angularity, and batch temperature. The product should therefore be specified by cut length, dosage, and standards compliance rather than by a single diameter value.
The fibre begins to soften near its melting point of 160–170 °C. It should not be exposed to steam-curing regimes above 150 °C because dimensional stability and fibre geometry may be degraded.
In a production-scale twin-shaft mixer of 1.0 m³ batch capacity, the product is introduced into the dry aggregate stream before cement and water. A dry pre-mix interval of 15–20 s allows the aggregate bed to strip the fibrillated bundles apart. At a forced-action pan mixer operating at 30–40 rpm, addition after the first water contact produced visible fibre balls on the paddle arms and reduced distribution uniformity across the discharge gate. The defect was eliminated by returning to dry-blend addition and by resealing opened bags after each withdrawal.
Slump loss measured under ASTM C143/C143M-20 at 0.9 kg/m³ is typically 5–15 mm; at 1.5 kg/m³, the reduction may reach 25 mm in low-slump concrete. A polycarboxylate-based high-range water reducer at 0.2–0.5% by cement weight may be used to restore target slump, but the admixture and fibre should be dosed at separate points in the mixer to avoid destabilising the air-entraining admixture.
Storage of opened bags above 70% relative humidity has been associated with fibre bundling and inconsistent feed behaviour. Bags should be stored flat, off damp floors, and opened at the point of use. If a dry handful does not separate under light mechanical action, the product should not be introduced into the automated batching line.
Fresh-state rheology under ASTM C1749-19 has shown that the relative plastic viscosity of concrete with 0.9 kg/m³ fibrillated polypropylene fibre may increase by 10–30% relative to the same mix without fibre, while the yield stress increase is generally below 10%. The torque response declines as mixing continues and the bundles open; a minimum wet mixing time of 90–120 s after water addition is used in high-shear mixers to reach a stable torque.
The product functions during the early plastic phase when bleeding, evaporation, and capillary pressure development control crack formation. In the first 8–12 h after placement, water moves upward through the fresh paste. When the evaporation rate at the surface exceeds the bleeding rate, water menisci in the capillary pores generate tensile stress. A plain cementitious matrix cracks when this stress exceeds the still-developing tensile capacity of the fresh paste. The fibrillated network interrupts bleed channels, reduces the continuity of water films around aggregate particles, and bridges incipient shrinkage cracks at multiple points within the same bundle.
Under ASTM C1579-21 restrained plastic shrinkage testing with surface evaporation held at 1.0 kg/m²/h, air temperature at 36 °C, and relative humidity at 30%, published laboratory studies on fibrillated polypropylene fibres of this class report total crack-area reductions of 80–100% at a dosage of 0.9 kg/m³ relative to a plain reference. Published data for the exact SINTA F formulation is limited; project concrete should be verified because cement content, silica fume, aggregate absorption, and admixture chemistry alter both the evaporation rate and the cracking response.
At 0.6 kg/m³ in a slab with water-cement ratio 0.55 and moderate wind exposure, field reports describe reduced but not eliminated early surface cracking. Increasing the dose to 0.9 kg/m³ eliminated visible plastic cracking in the same placement sequence. This dose-dependent response is consistent with the requirement that the fibre count per unit volume be high enough to bridge the active crack population before final set.
Because polypropylene is hydrophobic, the fibre does not corrode and does not undergo alkali-silica reaction. Its effect on the hardened air-void system is not neutral. Under ASTM C231/C231M-24, concrete containing fibrillated polypropylene fibre may show a 0.5–1.5% reduction in measured air content relative to the same mix without fibre, attributed to fibre-induced bubble coalescence during mixing and placement. Where freeze-thaw durability is specified under ASTM C666/C666M-15, the air-entraining admixture dose should be adjusted after fibre addition, and the air-void spacing factor should be checked to ensure it remains below 0.20 mm for critical exposure. The fibre is not a substitute for a correctly entrained air-void system.
In high-strength concrete exposed to fire, polypropylene micro fibres function as a pressure-relief mechanism after melting. The melting point of 160–170 °C is below the temperature associated with explosive spalling in dense low-permeability concrete. At dosages of 1.0–1.5 kg/m³, the fibrillated fibres create temporary channels that allow water vapour to escape under thermal gradients. Published fire test data for this exact product is limited, and the mechanism is documented for the broader class of polypropylene micro fibres under ISO 834-1:1999 and RWS temperature-time curves. Specification for structural fire resistance requires project-specific testing.
In rapid chloride penetration testing under ASTM C1202-22, addition of fibrillated polypropylene fibre at 0.9 kg/m³ has produced variable results depending on paste volume, curing age, and initial charge passed. Published data for this specific configuration is limited. The fibre increases interfacial transition zone volume but does not fundamentally alter the chloride diffusion coefficient of the cementitious matrix; it should not be specified as a chloride barrier.
SINTA F is considered an alternative to welded wire mesh only for early-age crack control in non-structural slabs, overlays, and similar flatwork. It does not provide structural load capacity after cracking, and it does not satisfy positive moment reinforcement requirements. The distinction is defined by test method. Steel mesh and macro fibres are evaluated by ASTM C1609/C1609M-24 or EN 14651 for residual flexural strength after cracking; fibrillated micro fibres are not designed to deliver measurable post-crack residual strength at the same order of magnitude. In slab-on-ground work where crack-width control is the only requirement and structural flexural capacity is provided by the concrete section itself, the product provides a low-maintenance alternative to mesh that eliminates the risk of mesh misplacement and surface corrosion.
| Attribute | SINTA F fibrillated PP | Monofilament PP | Macro-synthetic fibre |
|---|---|---|---|
| Geometry | Fibrillated film bundle opening into branched fibrils | Circular or oval solid strand | Embossed, twisted, or deformed heavy filament |
| Typical cut length | 6–19 mm | 6–19 mm | 30–65 mm |
| Typical dosage | 0.5–1.5 kg/m³ | 0.6–1.8 kg/m³ | 3.0–9.0 kg/m³ |
| Primary function | Plastic shrinkage and settlement crack control | Plastic shrinkage crack control | Post-crack residual flexural strength |
| Relevant classification | ASTM C1116/C1116M-15 Type III; EN 14889-2:2006 | ASTM C1116/C1116M-15 Type III; EN 14889-2:2006 | EN 14889-2:2006; ASTM C1609/C1609M-24 |
Under ASTM C1116/C1116M-15, both fibrillated and monofilament polypropylene fibres are classified as Type III synthetic fibres. The classification alone does not establish equivalent plastic shrinkage performance. The fibrillated architecture develops a branched mechanical anchor network in the fresh paste, while a solid monofilament relies on longitudinal bond along a smooth perimeter. Comparative selection should therefore be based on cut length, dosage, fibre count, and job-specific ASTM C1579-21 exposure, not solely on Type III designation.
Compared with cellulose fibres, polypropylene does not absorb water and does not degrade in the alkaline cement matrix. Compared with glass fibres, polypropylene is less susceptible to alkaline dissolution in ordinary portland cement, although glass fibre grades designed for cement resistance are outside this comparison. The operational boundary remains the same: SINTA F controls plastic-state cracking and does not provide structural flexural reinforcement.
The product is supplied under a factory production control system aligned with the provisions of EN 14889-2:2006 for polymer fibres for concrete, where applicable. CE marking information, when required, is declared on the packaging or delivery document. The polypropylene raw material is typically assessed for restricted substances under the relevant articles of REACH (EC) No 1907/2006 and, where applicable, RoHS Directive 2011/65/EU. Food-contact approval under FDA 21 CFR is not normally applicable for a concrete reinforcement fibre. Batch certificates should state cut length, specific gravity, and declared dosage tolerance. The purchaser should verify that the received product matches the reference sample because fibrillation geometry may vary with raw material lot and extrusion conditions.
In sprayed concrete and dry-mix application, fibrillated polypropylene fibres of this class are introduced at the dry-mix hopper or in the pre-dampened aggregate stream. The fibre can reduce rebound loss of fines and can control plastic cracking in the fresh sprayed layer, but the addition rate must be limited to avoid hose blockages at restrictive bends. Published data for this exact product in sprayed concrete is limited; spray trials under the intended nozzle configuration are required to establish a workable material flow.
At a pump boom configuration with 50 mm internal diameter hoses and a 90° elbow, adding fibre at 1.0 kg/m³ did not produce a measurable increase in pumping pressure. Increasing the dose to 1.5 kg/m³ produced a higher line pressure and transient blockage at the reducer in one observed placement. This operational limit is equipment-specific and should not be extrapolated without a trial.