| HS Code | 327283 |
| Manufacturer | CHRYSO |
| Brand | CHRYSO |
| Productname | Crackstop F |
| Producttype | Polypropylene fibrillated fiber |
| Material | 100% virgin polypropylene |
| Form | Fibrillated fiber |
| Colour | White / natural |
| Standardlength | 12 mm |
| Equivalentdiameter | Approximately 0.02–0.05 mm |
| Aspectratio | Approximately 200–600 depending on length |
| Density | 0.91 g/cm³ |
| Meltingpoint | 160–170 °C |
| Ignitionpoint | > 300 °C |
| Tensilestrength | 350–500 MPa |
| Elasticmodulus | 3–5 GPa |
| Elongationatbreak | 15–20% |
| Alkaliresistance | Excellent |
| Acidresistance | Excellent |
| Waterabsorption | Nil / < 0.1% |
| Thermalconductivity | Low |
| Electricalconductivity | Low |
| Magneticproperties | Non-magnetic |
| Typicaldosage | 0.6–1.8 kg/m³ of concrete |
| Packaging | 0.6 kg bags / 12 kg cartons |
| Shelflife | 12 months in original unopened packaging |
| Storageconditions | Dry, cool, away from direct sunlight |
| Compliance | ASTM C1116 Type III, EN 14889-2 |
| Primaryapplication | Concrete, mortar, screed, shotcrete |
As an accredited CHRYSO Crackstop F - Polypropylene Fibrillated Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | CHRYSO Crackstop F polypropylene fibrillated fiber is supplied in 20 kg moisture-resistant paper sacks, palletized for storage and handling. |
| Container Loading (20′ FCL) | 20′ FCL loading: palletized CHRYSO Crackstop F polypropylene fibrillated fiber bags, dry container, evenly distributed, secured, within payload limits. |
| Shipping | CHRYSO Crackstop F – Polypropylene Fibrillated Fiber is non-hazardous and not regulated for transport. It is typically supplied in moisture-resistant bags on pallets. Ship as general cargo by road, sea, or air under ambient conditions. No special labeling, placarding, or segregation required. Store dry and protect packaging from punctures and moisture. |
| Storage | Store CHRYSO Crackstop F - Polypropylene Fibrillated Fiber in a cool, dry, well-ventilated area in original unopened packaging. Keep away from direct sunlight, moisture, open flames, and strong oxidizers. Elevate pallets off damp floors and avoid crushing or contamination. Maintain clean, dust-controlled conditions. Observe shelf life and local regulations; consult SDS for specific handling and storage requirements. |
| Shelf Life | Shelf life: approximately 24 months from manufacture when stored dry, in unopened original packaging, away from direct sunlight and moisture. |
CHRYSO Crackstop F is a fibrillated polypropylene fiber supplied for addition to concrete and cementitious mortars. The raw polymer is stretched into film and slit into net-like fibrils that open during mixing, creating a fine three-dimensional distribution in the fresh paste. The primary performance function is control of plastic shrinkage cracking before initial set, when capillary tension in the drying surface exceeds the low tensile capacity of fresh concrete. The fiber is hydrophobic, has a density of approximately 0.91 g/cm³, is chemically stable in the alkaline cement environment, and does not corrode or contribute to galvanic corrosion. Published polypropylene fiber data place the elastic modulus in the range of 3.5–8.0 GPa, which is far below the modulus of the hardened concrete matrix; the product therefore functions as a micro-reinforcement for crack formation control, not as a structural load-bearing fiber. Under EN 14889-2:2006, polymer microfiber of this type is evaluated for conformity as a non-structural fiber for plastic shrinkage control, and it is not interchangeable with steel macrofibers in structural design. The addition does not require mix water adjustment, but it does require precise batching and dispersion control. The following scenarios are downstream applications where the material appears in production practice. The dosage ranges cited are typical starting points from concrete and shotcrete practice; the manufacturer’s current product data sheet remains the controlling document for formulation.
In industrial slab-on-grade production floors, plastic shrinkage cracking is the dominant early-age surface defect when unfavourable evaporation rates occur during placement and finishing. The fiber is added at a rate of 0.6–0.9 kg/m³, preferably through a silo-fed dosing screw into the aggregate stream before water and cement are added to a twin-shaft compulsory mixer. This sequence prevents fiber balling, which is observed when whole bags are thrown into wet concrete under high mixer speed. ACI 544.3R-08 summarises comparative restrained-evaporation data showing crack area reductions commonly in the range of 60–90% for fibrillated polypropylene fibers at 0.9 kg/m³ compared with plain reference panels. The placement is specified as Type III synthetic fiber-reinforced concrete under ASTM C1116/C1116M-23, and plastic shrinkage crack potential is assessed by ASTM C1579-20. Slump loss associated with the fiber is typically 10–25 mm, depending on water-cement ratio and polycarboxylate ether superplasticizer dosage; water should not be added solely to compensate for fiber-induced slump loss because that increases bleed and shrinkage. Finishing trials on production floors show that the slab must be bull-floated or pan-floated before steel trowel blades are used. If the finisher moves directly to trowel blades at high angle, dry surface fibers can increase blade drag and cause surface tearing. Joint sawing windows remain 6–12 h after final set, and fiber addition does not eliminate contraction joints. The fiber does not improve abrasion resistance under hardened-wheel traffic; wear performance remains dependent on aggregate hardness, water-cement ratio, and curing.
| Application segment | Typical dosage range | Relevant test or specification | Critical process constraint |
|---|---|---|---|
| Industrial slab-on-grade | 0.6–0.9 kg/m³ | ASTM C1579-20; ACI 544.3R-08 | Pan float before power trowel blades to embed surface fiber |
| Wet-mix shotcrete | 0.9–1.5 kg/m³ | EN 14488-2:2006; EFNARC sprayed concrete guidelines | Pre-disperse with aggregate to prevent pump hopper bridging |
| Precast elements | 0.6–1.2 kg/m³ | EN 14889-2:2006; EN 13369:2018 | High-frequency vibration can orient fiber near mould face |
| Fire spalling control | 1.5–3.0 kg/m³ | EN 1992-1-2:2004; ISO 834-1:1999 | Moisture and heating rate shift the minimum dosage threshold |
| Repair mortars and screeds | 0.6–1.0 kg/m³ | EN 1504-3; ASTM C928/C928M-20a | Gradual addition into paddle mixer to avoid fibre balls |
| Water-retaining concrete | 0.9 kg/m³ | ACI 350-20; EN 1992-3:2006 | Fiber does not replace steel reinforcement or waterstops |
| Pavements and white-topping | 0.6–1.2 kg/m³ | ASTM C94/C94M-24; EN 206:2013+A2:2021 | Non-metallic fiber does not interfere with paver sensors |
In wet-mix tunnel linings and slope stabilization, the addition of fibrillated PP fiber modifies fresh-state rheology and rebound behaviour rather than hardened compressive strength. The most common addition is 0.9–1.5 kg/m³ for crack control in temporary and permanent linings; at 2.0 kg/m³ and above, S-valve piston pumps may show increased line pressure and hopper bridging if fiber bags are discharged directly into the hopper. Field records indicate that fiber should be pre-blended with fine aggregate or metered through a silo screw into the charging sequence. In dry-mix shotcrete, fiber added after pre-dampening or at the nozzle creates uneven distribution and excessive rebound; it should be introduced at the pre-dampening stage so the transport air carries a homogeneous aggregate-fiber stream. Rebound of fibrillated PP fiber in dry-mix shotcrete can be 20–50% under non-optimum nozzle angles or air flow, requiring batch adjustment. The shotcrete matrix is tested under EN 14488-2:2006 for compressive strength, while fiber conformity is documented under EN 14889-2:2006. The presence of PP fiber does not replace welded wire mesh or rock bolts; it is a crack-control addition and not a structural bending reinforcement. When tunnel linings are designed for fire exposure, the dosage is typically increased to 1.5–2.0 kg/m³ for spalling reduction. No significant pump blockage is observed below 1.5 kg/m³ when the nozzle is held at 90°±10° to the substrate and the hopper is not allowed to run empty.
Precast production lines use the fiber at 0.6–1.2 kg/m³ in architectural cladding, utility boxes, and non-structural elements to reduce shrinkage cracking before curing is effective and to limit chipping during demoulding. In pan mixers and twin-shaft mixers, the fiber is added to dry aggregate before water and admixture; reverse-order addition can produce fiber balls. External vibration at 3,000–6,000 vpm on steel moulds can orient low-modulus fibrillated fibers parallel to the mould face. This tendency reduces visible cracking on the exposed surface but reduces fiber availability through the section and may produce sampling variability in wash-out tests. At 1.0 kg/m³, slump reduction of 10–20 mm is typical; the producer should adjust polycarboxylate ether superplasticizer rather than increase water to maintain workability. The demoulding time is governed by the binder system, and the fiber does not permit earlier stripping than the minimum strength required by EN 13369:2018. In thin architectural panels, the fiber does not substitute for alkali-resistant glass scrim, steel connections, or handling steel because it cannot provide structural flexural capacity. Plant trials should include a mixing time study, because prolonged high-shear mixing above 90 s after fiber addition can damage the fibrillated structure and create re-balled clumps in low-water mixes.
High-strength, low-permeability concretes are vulnerable to explosive spalling during fire because water-vapour pressure develops faster than moisture can escape through the matrix. Polypropylene fiber, including fibrillated types, melts at 160–170°C and leaves continuous channels that raise heated permeability. The critical variable is dosage. Published experimental programmes on concrete with compressive strength between 60 MPa and 100 MPa generally require 1.5–3.0 kg/m³ of polypropylene fiber to reduce spalling, but the minimum threshold changes with aggregate type, initial moisture state, heating rate, and section confinement. Fibrillated fiber may distribute melted channels more uniformly because of its higher surface area than monofilament fiber, but published independent data for this specific CHRYSO fiber configuration is limited. The design fire exposure is defined by ISO 834-1:1999, ASTM E119-22, and EN 1992-1-2:2004; hydrocarbon curves such as RWS used in tunnels impose a more severe heating rate, and standard curve results do not automatically validate hydrocarbon spalling resistance. At 2.0 kg/m³, the fiber reduces workability of low water-cement ratio concrete, usually requiring a higher polycarboxylate ether superplasticizer dosage to maintain a spread flow of 550–650 mm. The fiber must also be protected from sustained exposure above 120°C before placement because softening or distortion before fire reduces its spalling-control function.
For bonded repair mortars and cementitious screeds, polypropylene fibrillated fiber at 0.6–1.0 kg/m³ reduces early-age plastic shrinkage cracking in thin applications where water loss is rapid and the existing substrate restrains free movement. In paddle mixers, the fiber is added gradually into the running mixer because the lower mixing energy of a paddle mixer cannot disperse a full bag added at once; fibre clumping is a common batch failure. The repair product is specified under EN 1504-3 for structural and non-structural repair and under ASTM C928/C928M-20a for packaged dry materials. The fiber functions as plastic shrinkage control and does not provide load-bearing structural strengthening; structural repair capacity must come from the existing concrete section, added reinforcing bar, or approved structural reinforcement. In leveling screeds at 20–50 mm thickness, the fiber may reduce edge-curling cracks during drying but cannot correct substrate instability or excessive water content. Bond strength verification remains a separate requirement, tested under EN 1542 or ASTM C1583/C1583M-20, because published data for this specific fiber’s effect on adhesion is limited.
In water treatment basins, tanks, and marine-adjacent reinforced concrete, the fiber is added at 0.9 kg/m³ to reduce plastic settlement and plastic shrinkage cracks that become preferential water paths before hydration is complete. The fiber is non-corrosive in chloride-laden environments, unlike steel fiber, and is stable in the alkaline pore solution. However, its low elastic modulus means it cannot control long-term crack widths under tensile service loads. Crack control for hydrostatic service conditions must be provided by distributed steel reinforcement designed in accordance with ACI 350-20 or EN 1992-3:2006; the fiber is additional, not a substitute for reinforcement or joint waterstops. In low-permeability concrete with a water-cementitious ratio below 0.45, the addition of 0.9 kg/m³ may reduce visible plastic shrinkage crack counts in the range of 50–80% based on comparative site inspections, but this range is evaporation-rate dependent. The fiber does not reduce chloride diffusion or permeability of sound concrete; chloride resistance is governed by cover depth and binder chemistry. Claims that the fiber alone provides waterproofing are not supported by a recognised test standard.
Concrete pavement and bonded white-topping placements use the fiber at 0.6–1.2 kg/m³ to reduce early-age plastic shrinkage cracking and edge slumping before joint sawing. In slip-form paving, the non-metallic fiber does not interfere with stringline sensors or automatic grade-control equipment. The fiber is metered into the plant mix with the aggregate so that the continuous paver receives a homogeneous mixture; low water content and high-frequency internal vibration can otherwise cause uneven fiber distribution near the surface. The base pavement concrete is specified under ASTM C94/C94M-24 or EN 206:2013+A2:2021, and the fiber is accepted as an addition when its conformity is certified under EN 14889-2:2006. Joint spacing and dowel design are not altered by the fiber; contraction joints are still required at spacings determined by slab geometry and subgrade friction. Published field data for this specific fiber in slip-form pavement is limited, so qualification should compare crack density against an unreinforced control under the same evaporative conditions.
Mass concrete pour protection is limited to surface plastic shrinkage control at 0.6–0.9 kg/m³; the fiber does not influence core temperature rise and is not a thermal cracking control measure.
Competitive CHRYSO Crackstop F - Polypropylene Fibrillated Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
CHRYSO Crackstop F is a fibrillated polypropylene fiber supplied for concrete and mortar matrices. The fiber is manufactured from virgin polypropylene homopolymer with a specific gravity near 0.91 g/cm³, a melting point in the range of 160 °C–165 °C, and negligible water absorption. Its physical form is a compacted bundle of thin polypropylene films that separate into low-denier filaments under mechanical shear in a batch mixer. The fibrillated architecture distinguishes the product from round monofilament polypropylene microfibers: the opening process multiplies the number of individual filaments per unit mass, thereby increasing the number of crack interception sites per cubic metre. The product is typically dosed at 0.6 kg/m³–1.2 kg/m³ in ready-mix concrete; some producers specify lower or higher rates for sacrificial formwork or severe early-age exposure, but published product-specific data above 1.5 kg/m³ remain limited. Compliance claims for polymer fibers of this class are generally assessed under EN 14889-2:2006 for fibers with an equivalent diameter below 0.3 mm, and through ASTM C1116/C1116M for fiber-reinforced concrete classification.
The opening of fibrillated polypropylene is a shear-dependent process. In a transit mixer operated at approximately 14 rpm–18 rpm drum speed, the bundles require exposure to moving aggregate to split into continuous fibril networks. Addition sequence is as important as total mixing time: the product is added after aggregate and initial water have charged the mix, allowing aggregates to act as dispersing media. If the fiber is added with cement at the beginning of batching, the dry fiber can remain in discrete bundles or adhere to mixer walls, producing visible fiber balling at the discharge chute. Field reports from ready-mix plants indicate that balling is more frequent when the mixture temperature exceeds 32 °C and when silica fume or high-range water reducer is present because of reduced free water available for initial wetting. A staged addition procedure—introducing one bag after roughly half the coarse aggregate and allowing 30 seconds–60 seconds of high-shear dispersion before the remaining aggregate—is used on some production sites to prevent clumping. The total mixing time after fiber addition should meet the uniformity requirements of ASTM C94/C94M or EN 12350-1 sample verification, but is commonly extended by 3 minutes–5 minutes beyond standard batching when visual inspection shows unopened bundles.
Dosage selection is not governed solely by crack width class. A dosage of 0.6 kg/m³ is commonly specified where plastic shrinkage cracking is the only early-age risk, whereas 0.9 kg/m³–1.2 kg/m³ is used in slabs with large exposed surfaces or where evaporative conditions exceed 1.0 kg/m²/h of bleed water loss. At addition rates above 1.2 kg/m³, slump loss becomes measurable in mixes with low paste volume or coarse aggregate above 20 mm. The mechanism is not pozzolanic; the high specific surface area of the opened fibrils increases paste demand per litre and changes rheological yield stress. In low-slump concrete with 120 mm–150 mm slump before fiber addition, a reduction of 10 mm–30 mm can be observed after full dispersion, measured according to EN 12350-2. Producers compensate by adjusting high-range water reducer dosage rather than adding water to maintain water-cementitious materials ratio and compressive strength. Plastic shrinkage testing can be performed under ASTM C1579-21 using a restrained slab with controlled airflow; the result is comparative cracking area, not a structural capacity estimate.
| Parameter | CHRYSO Crackstop F fibrillated PP | Monofilament PP micro | Steel hooked-end macro |
|---|---|---|---|
| Geometry before mixing | Compacted fibrillated film bundle | Discrete cylindrical filament | Bundled hooked-end wire |
| Filament count per added mass | High after shear opening | Moderate fixed count | Low fixed count |
| Common dosage in ready-mix | 0.6–1.2 kg/m³ | 0.6–1.2 kg/m³ | 15–40 kg/m³ |
| Primary function | Plastic shrinkage crack reduction | Plastic shrinkage crack reduction | Post-crack structural capacity |
| Typical density | 0.91 g/cm³ | 0.91 g/cm³ | 7.85 g/cm³ |
| Corrosion in chloride exposure | None | None | Possible unless stainless or galvanized |
| Standards context | EN 14889-2:2006 Class I; ASTM C1116/C1116M Type III | EN 14889-2:2006 Class I | EN 14889-1:2006; ASTM A820/A820M |
In precast concrete, the substitution of a monofilament microfiber with CHRYSO Crackstop F changes the mixing and surface finish behavior. Fibrillated fibers can produce a higher filament count at the same dosage, which improves plastic shrinkage crack control but may reduce surface smoothness of form-facing elements if bundles do not fully open. Precast plants using high-shear pan mixers above 10 rpm achieve more complete fibril opening than low-shear drum mixers. The opened fibril network increases the surface defect risk at vertical form faces when the form release agent is applied in excess; fibrils can trap air or form release residues if strike-off or mechanical finishing operations are delayed beyond the initial set. Published comparative surface-burning tests for polypropylene microfibers are limited; however, field data from precast plants suggest that unopened bundles may appear as small fibrous inclusions near the surface after acid etching. When a smooth architectural finish is required, monofilament fibers are sometimes selected, but a reduction in dosage to 0.6 kg/m³ and early finishing can control surface disturbance.
For pumped concrete, the product is introduced at the batching plant, not at the pump hopper. The pipe pressure developed in high-rise placement can reorient fibrils; this orientation is not sufficient to provide structural moment capacity, but it does influence the fiber network anisotropy. In sprayed concrete, fibrillated microfibers are used to reduce rebound and control early-age shrinkage; the equipment must be fitted with a fiber feeder calibrated for the compressed-air stream. Published field data for CHRYSO Crackstop F in dry-mix shotcrete configurations are limited.
Polypropylene microfibers, including CHRYSO Crackstop F, are not a replacement for deformed steel reinforcement or macro-synthetic structural fibers. Their modulus of elasticity is typically 3.5 GPa–5.0 GPa, which is lower than concrete matrix modulus in compression, so they do not carry significant tensile stress after cracking. The function is confined to the plastic and early stiffening phase: the network reduces plastic settlement cracking, plastic shrinkage cracking, and some early-age thermal microcracking. Structural design must still comply with the reinforcement requirements of EN 1992-1-1 or ACI 318-19. If post-crack performance is required, steel fibers tested under EN 14845-1 or ASTM C1609/C1609M are used. Claims regarding crack width after hardening should not be based on plastic shrinkage tests alone; long-term crack control depends on reinforcement ratio, concrete cover, and moisture conditions.
Chemical durability of polypropylene in alkaline concrete is well established. The fiber is inert in the pH range of cement paste, typically 12.5–13.5, and does not corrode in chloride-bearing environments. In aggressive acid exposure below pH 4, the polypropylene itself may remain intact but the surrounding cementitious matrix degrades; therefore fiber integrity does not extend service life without adequate concrete cover and matrix quality. Polypropylene may soften at temperatures approaching its melting range; extended exposure of hardened concrete to service temperatures above 80 °C is outside the intended scope for plastic shrinkage microfibers. No published evidence indicates adverse reaction with lignosulfonate, naphthalene, or polycarboxylate admixtures.
| Compliance area | Standard or test method | Practical control point |
|---|---|---|
| Fiber polymer type and melt flow | ISO 1133-1:2022, ISO 3146:2022 | Incoming lot verification |
| Fiber class for concrete | EN 14889-2:2006 | Equivalent diameter below 0.3 mm |
| Fresh concrete workability | EN 12350-2 | Slump after fiber addition |
| Plastic shrinkage crack resistance | ASTM C1579-21 | Crack area comparison versus control |
| Fiber-reinforced concrete specification | ASTM C1116/C1116M | Type III synthetic fiber |
| Structural design limitation | EN 1992-1-1, ACI 318-19 | No steel reinforcement reduction |
Batch verification at the concrete plant includes checking fiber denier, melt flow index, and bundle integrity. Incoming lots are sampled according to EN 14889-2:2006 or the producer’s quality plan. A moisture content above 0.2 % may indicate damaged packaging or storage failure and should be rejected. Storage below 40 °C and protected from UV exposure prevents premature embrittlement; prolonged direct sunlight can initiate oxidative degradation of polypropylene. Production batching records should record dosage, addition time, and mixing revolutions.