Liwei Group Co., Ltd

Products

MasterFiber F 70 - Fibrillated Polypropylene Fiber from 100% Virgin Homopolymer Resin

    • Product Name: MasterFiber F 70 - Fibrillated Polypropylene Fiber from 100% Virgin Homopolymer Resin
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 162838
    Material 100% Virgin Polypropylene Homopolymer
    Fiber Type Fibrillated
    Specific Gravity 0.91
    Density 0.91 g/cm³
    Melting Point 160°C (320°F)
    Ignition Point 590°C (1094°F)
    Tensile Strength 550 MPa (80,000 psi)
    Modulus Of Elasticity 3.5 GPa (0.5 x 10^6 psi)
    Elongation At Break 15-25%
    Water Absorption Nil
    Alkali Resistance Excellent
    Acid Resistance Excellent
    Fiber Length 19 mm (3/4 in)
    Fiber Count 70 million per lb
    Color Natural
    Compliance ASTM C1116 Type III; ASTM D7508
    Dosage 0.6 to 1.8 kg/m³ (1.0 to 3.0 lb/yd³)
    Packaging 1 lb (0.45 kg) water-soluble bags; 50 lb (22.7 kg) cartons

    As an accredited MasterFiber F 70 - Fibrillated Polypropylene Fiber from 100% Virgin Homopolymer Resin factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing MasterFiber F 70 is supplied in 20 kg moisture-resistant bags, palletized and shrink-wrapped for safe storage.
    Container Loading (20′ FCL) Container Loading (20′ FCL): MasterFiber F 70 fibrillated polypropylene fiber from 100% virgin homopolymer resin, palletized bags, shrink-wrapped and secured.
    Shipping MasterFiber F 70 is non-hazardous polypropylene fiber, not classified as dangerous goods for transport. It ships in moisture-resistant bags on shrink-wrapped pallets. No UN number, placarding, or special handling required. Standard freight is acceptable; store dry, away from open flame.
    Storage Store MasterFiber F 70 in a clean, dry, well-ventilated area away from direct sunlight, heat, sparks, and open flames. Keep bags closed and palletized off the ground to prevent moisture pickup and contamination. Avoid excessive stacking and rough handling. Maintain ambient temperature; no special ventilation required. Keep away from strong oxidizers. Use original packaging and follow SDS/local regulations.
    Shelf Life Shelf life is typically 24 months from manufacture when stored in original unopened packaging under dry, protected, room-temperature conditions.
    Application of MasterFiber F 70 - Fibrillated Polypropylene Fiber from 100% Virgin Homopolymer Resin

    MasterFiber F 70 is metered into ready-mixed concrete at 0.3 kg/m³ to 1.8 kg/m³ for large-area industrial ground slabs, container yards, logistics hardstandings, and external apron pavements. The fibrillated polypropylene fibre, manufactured from 100% virgin homopolymer resin, opens during the mixing cycle into a network of fine microfilaments that interrupt capillary pore pressure during plastic settlement. Under ASTM C1579-21 comparative testing, published studies on fibrillated polypropylene microfibre in concrete often record plastic shrinkage crack length reductions in the range 50–90% between 0.6 kg/m³ and 1.8 kg/m³, depending on evaporation rate, wind speed, concrete class, and aggregate consistency. Product-specific verification under job-site ambient conditions remains necessary because crack severity is governed by environmental drying rate rather than fibre addition alone. In a 1.0 m³ twin-shaft compulsory mixer, fibre distribution is improved when the fibre is added to dry aggregate before cement and water injection, followed by wet mixing for at least 90 seconds after the final water addition. Batch-to-batch variation appears when the fibre is added to a truck drum after batching, because partially opened tendon bundles can remain visible in the discharge as small entangled clusters. The principal process boundary is slump reduction; trial mixes should be tested under EN 12350-2:2019 for slump and EN 12350-7:2019 for air content, since fibrillated fibre surfaces can alter the entrained air-void spacing factor measured under ASTM C457/C457M-23. Published data for this specific product configuration is limited, so batching adjustments must be verified on the exact plant mixer and transport route.

    Fibrillated PP fibre addition windowObserved fresh concrete responseHardened crack-control role
    0.2–0.6 kg/m³Minimal slump loss in most C25/30 to C35/45 concretesEarly-age plastic shrinkage crack reduction only
    0.6–1.2 kg/m³Slump correction may require trial batching with a high-range water reducerPlastic shrinkage suppression and thermal microcrack arrest
    1.2–1.8 kg/m³Noticeable loss of flow; air content verification requiredSevere plastic settlement conditions and fire-spalling mitigation where specified

    What Does EN 14889-2 Require Before Polypropylene Fibre Enters Concrete Specification?

    In structural slab and paving applications where specification compliance is non-negotiable, the fibre must be assessed under EN 14889-2:2006 for polymer fibres for concrete. That standard requires evaluation of nominal length, tensile strength, alkali resistance, and dimensional stability. Third-party test reports should confirm that the fibre is made from 100% virgin homopolymer resin rather than reprocessed material, because recycled content can introduce surface oxidation and reduce tensile strength. Under ASTM C1116/C1116-23, synthetic fibres are classified as Type III for concrete reinforcement. Fibrillated polypropylene fibres in this class are used primarily for crack control, not as a replacement for embedded steel or for load-bearing macro-synthetic reinforcement. The mechanical distinction is material: a polypropylene fibre with a fibrillated cross-section creates mechanical anchorage through branching, but its elastic modulus is generally reported in the range 1.5 GPa to 4.0 GPa, far below steel or glass fibre, so post-crack residual flexural performance is limited. Incoming resin lots should be verified for melt flow rate under ISO 1133-1:2022 and density under ISO 1183-1:2019, because small changes in melt-flow ratio affect fibrillation during film extrusion and subsequent fibre opening in concrete mixers. No specification should rely on this fibre to provide load-bearing crack-width control in beams or suspended slabs unless explicitly justified through flexural testing under ASTM C1609/C1609M-19 and approved by the project engineer.

    Standard or RegulationApplication Check for Fibrillated PP Fibre
    EN 14889-2:2006Conformity of polymer fibres for concrete; check tensile strength, length, alkali resistance, dimensional stability, and CE marking.
    ASTM C1116/C1116-23Type III synthetic fibre reinforced concrete specification; confirms material class for crack control.
    EN 12350-2:2019Slump test for fresh concrete; establishes workability shift after fibre addition.
    EN 12350-7:2019Air content test; verifies fibre effect on entrained air-void system.
    REACH 1907/2006/ECRegistration and safe use obligations for polypropylene fibres supplied in the European Union.

    In precast tunnel segment production, the fibre is commonly batched at 1.0 kg/m³ to 2.0 kg/m³ to reduce explosive spalling during a hydrocarbon fire. Polypropylene homopolymer fibre melts between 160 °C and 170 °C under slow heating, leaving a network of interconnected channels after pyrolysis that relieves vapour pressure in the high-performance concrete matrix. This mechanism is recognised in fire-resistant concrete design under EN 1992-1-2:2004 and is evaluated through full-scale furnace tests such as the RILEM TC 256-SPF series. At batch level, the fibre is dispersed through a high-energy pan mixer with a wet mixing phase not shorter than 120 seconds; however, fibre addition can reduce rheological flow by 10–20% depending on aggregate angularity and cement paste volume. In a continuous line producing 2.5 m wide segments, discharge from the mixer into a skip hoist usually requires a hopper grate of at least 40 mm opening to prevent partially opened fibre clusters from bridging. Product-specific published performance for MasterFiber F 70 in full-scale tunnel fire tests is limited, so fire design values should be validated on the exact concrete formulation under project-specific thermal loading. Processors record that fibre segregation in the hopper is exacerbated when moisture is introduced before fibre, because dry fibre bundles can absorb static charge and cling to cold steel surfaces; adding fibre to the moving aggregate stream reduces this incidence.

    Shotcrete Rebound Loss and Fibre Loss Through Wet-Mix Nozzle Systems

    For slope stabilisation and underground shotcrete lining, fibrillated polypropylene fibre is introduced at 0.3 kg/m³ to 1.5 kg/m³ into wet-mix sprayed concrete before the piston pump inlet. The critical processing boundary occurs at the nozzle tip, where compressed air expands and fibre filaments are accelerated onto the substrate; rebound is dependent on air pressure, nozzle diameter, aggregate grading, and wall viscosity. Under EFNARC measurement guidelines, rebound values for wet-mix sprayed concrete commonly range from 10% to 25%, but published data for this specific fibrillated PP product in high-velocity nozzle streams is limited. Fibrillated fibre can alter sprayability because the branched network increases yield stress in the fresh concrete; this requires adjustment of the high-range water reducer to maintain a slump of 150 mm to 200 mm before pump suction. In 25 mm to 40 mm nozzle diameters, fibre clusters that have not fully opened may reduce line pressure stability and increase pulsation, particularly after pumping distances over 60 m. Production crews observe fewer line blockages when the fibre is dry-blended with cement before the paste phase and when the pump hopper screen is not smaller than 12 mm. The fibre contributes to crack reduction in the early curing period but does not provide significant flexural hardening; structural sprayed concrete design must follow EN 14487-1:2005 and fibre energy absorption testing under EN 14488-5:2006 when post-crack toughness is required.

    When Cementitious Floor Screeds Are Pumped Over 80 m, Fibre Addition Changes Flow Table Behaviour

    In pumpable cement-based screeds and floor underlayments specified under EN 13813:2002, fibrillated PP fibre is added at 0.3 kg/m³ to 0.9 kg/m³ to reduce early shrinkage fissures during forced-air drying and underfloor heating cycles. The small dosage is deliberate because above 0.9 kg/m³ the branched fibre network reduces flow table spread by 20–40 mm in a mix with 220 mm initial flow, depending on sand grading and water-binder ratio. Pumping through 80 m to 120 m of 25 mm internal diameter delivery hose requires stable rheology; fibre bundles that absorb mixing water slowly can create early stiffening in the hose after restart from a cold joint. On a production floor, adding fibre to pre-dampened aggregate before the binder addition reduces the incidence of flow table fluctuation between the first and third loads. Published data for this specific product in 80 m pumping circuits is limited; therefore, full-scale pump trials should include pressure drop measurement and flow table testing under EN 13318:2000 for screed material. The hardened screed properties that benefit from fibre are early-age shrinkage cracking and surface edge spalling during panel cutting, not flexural strength; load transfer in industrial warehouses remains dependent on joint design and steel reinforcement where specified.

    In repair mortars and patch placement on bridge decks and car park ramps, the fibre is dry-premixed into prepacked formulations at 0.2 kg/m³ to 0.5 kg/m³. The mixing environment is typically a high-shear countercurrent mixer operating at 200–300 rpm; the low addition rate limits viscosity increase while still interrupting plastic settlement in deep patch pockets. Fibrillated PP fibre performs differently from monofilament PP because the film-derived microfilaments create larger internal surface area per unit mass, which can flocculate if mixed with high-viscosity polymer latex and then defoamer is added too late. The operational boundary is therefore sequence: blend fibre with dry binder for 60 seconds, add polymer dispersion under low speed, then add defoamer and sand. Published data for this exact sequence with MasterFiber F 70 is limited, but the general mechanism is consistent with dispersion studies in polymer-modified cementitious binders. Patch acceptance testing should include ASTM C928/C928M-20a for packaged repair materials and EN 1504-3:2005 for structural and non-structural repair; bond strength tests under EN 1542:1999 confirm that the fibre does not lubricate the substrate interface in a way that lowers pull-off values.

    Polymer-Modified Toppings Demand a Defoamer Before Fibre Addition Under High Humidity

    Polymer-modified cementitious toppings applied at 6 mm to 25 mm thickness in food-grade and industrial process areas represent a secondary downstream use where fibrillated PP fibre assists with microcrack bridging under thermal sanitising cycles. The addition window of 0.5 kg/m³ to 1.0 kg/m³ must be verified against the polymer dispersion because anionic styrene-butadiene latices can interact with the fibre surface; if the polymer carries a high surface charge, mixing energy input in a planetary mixer above 150 rpm may create fibre agglomerates at the vessel wall. Pre-wetting the fibre with a small quantity of gauging water before polymer addition has been observed to reduce clumping when relative humidity in the plant exceeds 60%. Published data for this specific product with styrene-butadiene latex is limited; compatibility testing under EN 1504-3:2005 and crack resistance measurement under ASTM C1581/C1581M-18a should be undertaken before adopting a formulation. The hardened topping does not rely on the fibre for compressive strength, and dosage adjustment must be halted if air content measured by ASTM C231/C231M-24 falls below 4% where freeze-thaw exposure is specified under ASTM C666/C666M-15.

    Free Quote

    Competitive MasterFiber F 70 - Fibrillated Polypropylene Fiber from 100% Virgin Homopolymer Resin prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber F 70 is a fibrillated polypropylene fiber manufactured from 100% virgin homopolymer polypropylene resin. The resin is extruded into an oriented film and mechanically fibrillated to produce an interconnected network of polypropylene filaments with rectangular cross-sections and longitudinal fibrillation. Under ASTM C1116/C1116M-23, the material classifies as a Type III synthetic fiber for fiber-reinforced concrete. The product is commonly supplied as collated fiber bundles with a nominal length of 19 mm. The base resin has a specific gravity of 0.91 when measured according to ASTM D792-20, water absorption below 0.1% after 24 h immersion under ASTM D570-22, and a melting temperature in the range 160–170 °C under ASTM D3418-21. The virgin homopolymer designation excludes recycled polyolefin content, reducing melt-flow variation and pigment-related heterogeneity in the fiber batch. The hydrophobic polymer matrix does not absorb mix water, which separates the product from cellulosic or hydrophilic synthetic fibers that display measurable water uptake.

    Fibrillated film morphology creates a high specific surface area relative to round monofilament fibers. The interconnected fibrils separate during mixing and form a three-dimensional network in fresh concrete, but the material is not intended as primary reinforcement and does not replace structural steel or macro synthetic fibers. Its function is limited to secondary crack control in cementitious matrices.

    What distinguishes fibrillated virgin homopolymer fibers from monofilament and steel fiber systems?

    Fiber geometry and polymer source, rather than fiber count alone, govern dispersion and mechanical behavior in concrete. Fibrillated fibers begin as bundles of interconnected film fibrils and must be mechanically separated during mixing. In contrast, monofilament polypropylene fibers are extruded as discrete round strands and disperse more readily but provide less surface-topographic anchorage. Hooked-end steel fibers provide structural residual flexural capacity because their elastic modulus is approximately 200 GPa and their tensile yield strength is typically 1,100–1,500 MPa. Polypropylene fibers exhibit an elastic modulus of 3.5–4.5 GPa and tensile strength commonly reported at 300–600 MPa, so their structural contribution is confined to early-age crack width control and microcrack arrest rather than replacement of reinforcing bars or welded wire reinforcement. MasterFiber F 70 therefore belongs to the microsynthetic fiber class for concrete, not to the macro-synthetic or steel fiber structural class.

    The use of 100% virgin homopolymer resin differentiates MasterFiber F 70 from fibers containing recycled polyolefin feedstocks, which may show greater fluctuation in melt flow rate, tensile response, and pigment distribution. For incoming resin, melt flow rate can be monitored under ISO 1133-1:2022; this test is relevant because fibrillation performance depends on the orientation and molecular weight of the extruded film. Recycled feedstocks can contain mixed polymer species, which create inconsistent fibrillation and lower bundle separation efficiency in low-shear concrete mixers.

    PropertyMasterFiber F 70 fibrillated polypropyleneMonofilament polypropylene microfiberHooked-end steel fiber
    Base resin100% virgin homopolymer polypropylenevirgin polypropylenelow-carbon steel wire
    Fiber geometryfibrillated network bundleround discrete filamenthooked-end or crimped wire
    Nominal length19 mm6–12 mm30–60 mm
    Specific gravity0.91 under ASTM D792-200.917.85
    Water absorption<0.1% under ASTM D570-22<0.1%not applicable
    Tensile strength300–600 MPa representative range under ASTM D638-22450–700 MPa1,100–1,500 MPa
    Elastic modulus3.5–4.5 GPa3.5–4.5 GPa200 GPa
    Typical concrete addition0.9–1.8 kg/m³0.9–1.8 kg/m³15–60 kg/m³
    Primary functionplastic shrinkage and microcrack controlplastic shrinkage controlstructural residual capacity and crack-width limitation

    Batching sequence affects dispersion of fibrillated fibers more than initial fiber moisture content. On dry-batch plants, the fiber bundle should be added to the fine aggregate stream after the initial aggregate charge but before water introduction. This sequencing allows the dry fiber to spread across the aggregate mass and separates fibrils under subsequent aggregate shear. In truck-mix operations, adding a full bag directly into the water stream or onto wet concrete can create cohesive fiber balls that are not dispersed by normal drum mixing at 12–18 rpm. Production plants use low-rate fiber dispensers to release opened bags over a 20–30 s conveyor period, or add the opened bundle to the central mixer with the aggregate fraction. After water addition, a minimum of 70–100 revolutions of the truck drum at mixing speed is required for uniform distribution at an addition rate of 0.9 kg/m³. Central mixers such as twin-shaft compulsory mixers or planetary mixers disperse the fiber network more efficiently than free-fall drum mixers; 60–90 s of wet mixing after fiber introduction is generally sufficient. If the discharged concrete shows visible fiber clumps, the fleet should be checked for worn blades, insufficient mixing speed, or bag addition rate rather than increasing water content. The fiber is hydrophobic and does not absorb mix water, so observed slump changes are dominated by increased yield stress from the fiber network rather than increased water demand. Slump measured to ASTM C143/C143M-20 should be recorded before and after fiber addition; typical reductions at 0.9 kg/m³ are in the range 10–25 mm for a 0.45 water-to-cementitious ratio mix with crushed limestone aggregate. Workability is restored by adjusting the dosage of a Type A or Type F water-reducing admixture meeting ASTM C494/C494M rather than by adding excess water, which would lower compressive strength. Batching tolerance for the fiber dosage should be controlled within ±0.1 kg/m³ of the specified addition; low-speed auger dispensers generally achieve this more reliably than aggregate weigh-belt systems.

    When plastic shrinkage crack control governs specification, how is dosage validated?

    When specified for plastic shrinkage mitigation in slab-on-grade placements, the addition rate is generally 0.9 kg/m³ according to the manufacturer’s technical documentation. Rates from 0.6 kg/m³ to 1.8 kg/m³ are used for higher-risk placements such as large exposed panels, wet-mix shotcrete, and slip-formed barriers. The 0.9 kg/m³ addition provides sufficient fiber count to bridge plastic capillary pores while maintaining pumpability. Validation of crack reduction is performed using ASTM C1579-21, in which a restrained rectangular panel is subjected to controlled evaporative loss and the crack width reduction is compared with an unreinforced control. A crack-width reduction of at least 50% at the specified dosage is a commonly referenced acceptance threshold, although project specifications may require higher reduction at 60% relative humidity and 30 °C surface temperature. For each mix revision—especially changes in supplementary cementitious material content, fine aggregate angularity, or water-to-cementitious ratio—the plastic shrinkage test should be repeated because fiber effectiveness is influenced by matrix pore pressure, bleeding rate, and early-age tensile stress development. The product does not reduce drying shrinkage occurring after final set; hardened drying shrinkage is evaluated by ASTM C157/C157M and is not the acceptance method for this fiber.

    Under hot-weather placement, the concrete bleeding rate and set time govern plastic shrinkage. The fiber must be present in the near-surface mortar fraction to intercept capillary stresses. Contractor experience on slab placements with laser screeds indicates that fiber ball accumulations can be reduced by maintaining drum speed at 14 rpm and adding the fiber before the last third of the batch water. Because the fiber network reduces bleed water transport to the surface, finishing operations may begin earlier than on plain concrete; bleed rate can be measured by ASTM C232/C232M-20. Surface texture should be checked with a straightedge because fiber-reinforced concrete may produce a tighter surface with less available bleed water.

    On slab-on-grade construction, MasterFiber F 70 is typically introduced through the aggregate weigh hopper or by a fiber dispenser mounted over the coarse aggregate conveyor. The fiber network distributes through the low-slump concrete without changing the water-to-cementitious ratio. In precast operations using self-compacting concrete, the addition rate should be limited to the lower range, usually 0.6–0.9 kg/m³, because higher fiber volumes can reduce passing ability through narrow form sections; J-ring tests to ASTM C1621/C1621M-17 should be performed on the self-compacting concrete after fiber addition. In wet-mix shotcrete, the fiber can be added during batching; nozzle clogging is not generally caused by the fiber itself but by balled bundles if mixing energy is inadequate. The use of pre-dampened aggregates is allowed, but fiber bags must remain dry until addition. The material is stable in the alkaline cement matrix and does not undergo the corrosion mechanisms associated with steel fibers. However, because polypropylene melts between 160–170 °C, the fiber should not be considered a fire-resistance reinforcement; its contribution diminishes as the matrix temperature exceeds the polymer melt temperature.

    At addition rates above 1.8 kg/m³, pump line pressure can increase due to higher plastic viscosity. For long pump lines over 150 m, a pumping trial is recommended using the actual boom pump configuration and a pressure transducer recording line pressure. Fibrillated fiber addition does not alter cement hydration kinetics, because the polymer is inert and hydrophobic; isothermal calorimetry shows no measurable acceleration or retardation of silicate phase hydration attributable to the fiber. However, the three-dimensional fiber network can physically interact with entrained air void stability, so air content should be measured before and after addition with a pressure meter meeting ASTM C231/C231M-17a.

    Material identity, storage, and batch-to-batch quality verification

    Incoming lot inspection begins with identification of fiber type, nominal length, and fibril bundle integrity. Because the product is manufactured from virgin homopolymer resin, the melt flow rate and ash content are generally more stable than recycled blended fibers; nevertheless, each shipment should be checked against supplier certificates and retained samples subjected to oven-dry mass loss at 105 °C for 1 h. Storage below 50 °C and away from direct sunlight prevents softening and bundle compression from causing fiber agglomeration. Opened bags should be resealed to keep the fibers dry and free of cement dust; contamination with fine cement powder creates localized clumps that reduce dispersion. A standard lot check includes specific gravity by ASTM D792-20, water absorption by ASTM D570-22, and melt temperature by ASTM D3418-21. Fiber length distribution can be verified from the manufacturer’s certificate against ASTM C1116/C1116M-23. For full compliance, the concrete producer maintains batch records of fiber addition per cubic meter, mixing time, slump before and after fiber, and plastic shrinkage test results where specified. In jurisdictions requiring CE marking for fibers used in concrete, the applicable harmonized standard is EN 14889-2:2006; product properties must be declared on the basis of type testing and factory production control.

    Property or requirementReference methodTypical value or acceptance criterion
    Fiber classificationASTM C1116/C1116M-23Type III synthetic fiber
    Specific gravityASTM D792-200.91
    Water absorptionASTM D570-22<0.1% after 24 h
    Melt temperatureASTM D3418-21160–170 °C
    Plastic shrinkage crack reductionASTM C1579-21project-specified reduction versus plain control
    Fresh concrete slumpASTM C143/C143M-20batch-specific target range
    Air content stabilityASTM C231/C231M-17awithin project air-void specification

    Because polypropylene has a melt temperature near 165 °C, the fiber loses tensile capacity in fire-exposed concrete; therefore, fire-resistance rating is not improved by this product. MasterFiber F 70 is not intended to replace steel reinforcing bars, welded wire reinforcement, or structural macrofibers. It is incompatible with applications requiring post-crack residual flexural strength measured to ASTM C1609/C1609M-19, because the fiber length and modulus are too low to generate significant residual load after crack opening. In flooring systems where high point loads or jointless structural slabs are specified, the design should be performed with steel reinforcing or macro synthetic fibers, and MasterFiber F 70 should be limited to secondary crack control. Do not store in a moist environment above 60% relative humidity if bags are not sealed; although polypropylene absorbs minimal water, surface moisture on bundles promotes clumping. Published product-specific data for high-temperature performance and long-term creep of the fiber in cracked concrete is limited.