Liwei Group Co., Ltd

Products

MasterFiber M 687 - Next-Generation Fibrillated Polypropylene Fiber

    • Product Name: MasterFiber M 687 - Next-Generation Fibrillated Polypropylene Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 143448
    Product Name MasterFiber M 687 - Next-Generation Fibrillated Polypropylene Fiber
    Manufacturer Master Builders Solutions
    Material 100% Virgin Polypropylene
    Fiber Type Fibrillated
    Form Fibrillated Network
    Color Natural/White
    Fiber Length 19 mm (0.75 in)
    Specific Gravity 0.91
    Tensile Strength Approximately 550 MPa
    Young S Modulus Approximately 3.5 GPa
    Melting Point 160-170 °C
    Ignition Temperature >350 °C
    Alkali Resistance Excellent
    Water Absorption Nil
    Typical Dosage 0.9 kg/m³ (1.5 lb/yd³)
    Packaging 0.6 kg bags and 20 kg boxes
    Standards ASTM C1116 Type III, ASTM C1399, EN 14889-2

    As an accredited MasterFiber M 687 - Next-Generation Fibrillated Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing MasterFiber M 687 is supplied in 20 kg moisture-resistant paper bags, palletized for efficient bulk storage and transport.
    Container Loading (20′ FCL) 20′ FCL: MasterFiber M 687 fibrillated polypropylene fiber in palletized bags; load evenly, secure, keep dry, well-ventilated, per transport regulations.
    Shipping MasterFiber M 687 is a non-hazardous, non-regulated polypropylene fiber. It ships as a solid construction material in sealed bags, sacks, or bulk containers, protected from moisture and contamination. No UN number, hazard class, packing group, or special transport markings are required under DOT, IMDG, or IATA.
    Storage Store MasterFiber M 687 in its original, unopened packaging in a cool, dry, well-ventilated area. Protect from moisture, direct sunlight, excessive heat, and ignition sources. Keep pallets off damp floors and avoid crushing or damaging bags. Use first-in, first-out rotation. Store away from incompatible materials and observe manufacturer shelf-life recommendations.
    Shelf Life Shelf life is 24 months from manufacture when stored dry, in original unopened packaging, away from moisture and direct sunlight.
    Application of MasterFiber M 687 - Next-Generation Fibrillated Polypropylene Fiber

    The plastic shrinkage phase in slab-on-ground concrete begins when the surface evaporation rate exceeds the bleeding rate and capillary pressure within the pore water surpasses the tensile strain capacity of fresh mortar. MasterFiber M 687 is added at 0.9 kg/m³ to 1.8 kg/m³ to form a three-dimensional network within the upper 10 mm to 50 mm of the slab surface; at a fiber specific gravity of 0.91, this range corresponds to approximately 0.1% to 0.2% by volume. The fiber conforms to ASTM C1116/C1116M-10a Type III and EN 14889-2:2006 as a synthetic polymer fiber. In a central mixer, the fiber is introduced onto the dry aggregate stream before water and cement are charged, and mixing continues for 5 minutes after the final bag is added to separate the fibrillated bundles. In a truck mixer, dispersion requires at least 70 revolutions at 12 rpm to 18 rpm after fiber addition; field records should note drum fin condition because worn fins leave visible fiber clusters near the charging hopper. If the slump measured by EN 12350-2:2019 falls more than 30 mm below the reference target, the dosage is reduced or a high-range water reducer is added instead of increasing free water. When an air-entrained mix is specified, the air content is rechecked by ASTM C231/C231M-17 because hydrophobic fibrillated fibers can alter the air-void system during compaction. The slab is finished and bull-floated according to ACI 302.1R-15, and the saw-cut pattern remains controlled by ACI 360R-10; the fiber does not replace contraction joint layout. Plastic shrinkage crack performance is assessed by ASTM C1579-21 using a restrained slab configuration, with acceptance determined by crack area reduction relative to a control mix; published data for this specific configuration is limited, so each project requires a preconstruction comparison slab under the expected evaporation and wind conditions. MasterFiber M 687 is not a structural substitute for steel fiber residual strength measured by ASTM C1609/C1609M-19, and it is not permitted as primary flexural reinforcement in suspended slabs unless approved by the engineer of record. Bags are stored at relative humidity below 60%, and fiber bundles that no longer separate under normal mixing shear are rejected.

    Does a Fibrillated Polypropylene Fibre Alter Demoulding Cycles in Precast Concrete Component Production?

    Precast utility structures, catch basins, conduit boxes, and wet-cast pipe bases are produced on fixed cycle times controlled by form turnover, early-age compressive strength, and surface finish. MasterFiber M 687 is charged at 0.9 kg/m³ to 1.2 kg/m³ in wet-cast concrete conforming to EN 13369:2018; the lower half of the range is used when exposed aggregate retarders or polished form faces are specified. Fiber is added to a planetary pan mixer after the sand fraction and before cement, followed by 4 minutes to 5 minutes of mixing at 18 rpm to 20 rpm. Because the polymer filaments are hydrophobic and non-absorptive, no additional batch water is required, and slump retention measured by EN 12350-2:2019 remains within 10 mm to 20 mm of the reference when a polycarboxylate superplasticizer is present. The fiber does not increase early-age compressive strength measured by ASTM C39/C39M-21 or EN 12390-3:2019; therefore demoulding times based on strength development remain unchanged. In precast self-consolidating concrete, dosages above 1.5 kg/m³ can reduce slump flow measured by EN 12350-8:2019 and cause surface blemishes at the form face, while vibrated wet-cast units typically tolerate up to 1.8 kg/m³ before visible clumping appears. Box culvert sections, manhole bases, headwall units, and utility vaults produced with the fiber show fewer edge spalls during stripping and handling, but the product is not a demoulding aid. Documentation for CE marking under EN 13369:2018 includes fiber type, dosage tolerance, and mixing time in the batch record. Dry-cast pipe production with a water-cement ratio below 0.30 does not provide sufficient lubricating paste for fibrillated fiber dispersion, and this application is not recommended unless plant-specific compaction trials confirm adequate distribution.

    In wet-process shotcrete, the allowable fiber length is governed by the smallest diameter in the pumping circuit, usually the nozzle reduction, and by the delivery line length. MasterFiber M 687 is batched into the transit mixer at 0.9 kg/m³ to 1.8 kg/m³ for plastic shrinkage control before the material enters the shotcrete pump; mixing continues for 5 minutes after the last bag to allow the fibrillated bundles to disassociate. The placed shotcrete is specified under EN 14487-1:2005. For a 50 mm nominal delivery hose, the fiber length should not exceed 19 mm to reduce agglomeration at reducers and to prevent buildup at the nozzle. The wet-mix is pumped at 8 m³/h to 15 m³/h through 50 mm or 65 mm high-pressure hose, and the nozzle operator introduces alkali-free or aluminate-based accelerator at the nozzle tip. Polypropylene is resistant to cementitious alkalinity above pH 12.5, but early gel formation from aggressive aluminate accelerators can limit fiber redistribution during spray application. Rebound changes the observed fiber content at the placed surface relative to the batched dosage, so in situ fiber content is verified by EN 14488-7:2006, and flexural toughness is evaluated by EN 14488-2:2006 when required. The fiber is not intended to provide structural energy absorption; for permanent linings with energy absorption demand above typical microsynthetic capacity, steel or macro-synthetic fibers are specified instead. End products include temporary rock support, slope stabilization panels, and tunnel primary linings where crack control in the fresh state reduces the early-age surface damage that promotes rebound and shadowing under poor ground conditions.

    Application-specific acceptance standards referenced in this document
    Downstream sectorFiber classification standardPerformance test methodField control parameter
    Slab-on-ground flatworkASTM C1116/C1116M-10a Type IIIASTM C1579-21Dosage 0.9–1.8 kg/m³; mixing 5 minutes
    Precast utility structuresEN 14889-2:2006EN 12350-2:2019Slump retention 10–20 mm; dosage 0.9–1.2 kg/m³
    Wet-process shotcreteEN 14487-1:2005EN 14488-7:2006In-place fiber content; hose 50 mm minimum
    Bridge deck overlayASTM C1116/C1116M-10a Type IIIASTM C1579-21Dosage 0.9–1.5 kg/m³; dry blending before latex
    Marine mass concreteEN 14889-2:2006EN 12350-2:2019Dosage 0.9 kg/m³; w/c ≤ 0.45

    When Bridge Deck Overlays Replace Welded Wire Mesh with Synthetic Fibres

    Because bridge deck overlays are bonded to a substrate that may already contain structural cracks, control of plastic shrinkage in the fresh overlay determines whether the repair remains protective after traffic loading resumes. MasterFiber M 687 is added at 0.9 kg/m³ to 1.5 kg/m³ in a low permeability overlay mix that typically contains silica fume or a styrene-butadiene latex admixture and a maximum water-cementitious ratio of 0.42. The fiber is blended with dry materials before liquid latex and water are introduced; adding fiber directly to the liquid latex phase causes clumping and non-uniform surface finish. The overlay is placed at a thickness of 32 mm to 45 mm and finished by screed and float; the reduction in fresh-state shrinkage drag is quantified by ASTM C1579-21 comparative testing before field placement. Compressive strength is tested by ASTM C39/C39M-21, flexural strength by ASTM C78/C78M-18, and chloride permeability by ASTM C1202-22. The fiber is classified under ASTM C1116/C1116M-10a Type III and does not create a corrosion path within the overlay; this is a distinct field advantage over welded wire reinforcement in chloride environments. However, the fiber does not increase the structural flexural capacity of the overlay, and deck slabs requiring positive moment reinforcement must retain the designed steel reinforcement. High ambient temperature above 35 °C reduces the working time of latex-modified overlays and can make fiber dispersion more difficult; night placement or chilled mix water is recommended where the surface temperature of the deck exceeds this threshold.

    Marine Exposure and Sulfate-Resistant Mass Concrete Placements

    For sulfate-resistant mass concrete placed in tidal zones, the exposed surfaces develop plastic shrinkage stress faster than interior concrete because wind and solar radiation drive moisture loss from the top lift. MasterFiber M 687 is incorporated at 0.9 kg/m³ in concrete specified under EN 206:2013 exposure classes XS2 or XA2 and BS 6349-2:2019 for marine works. The binder is a sulfate-resisting cement or slag-blended system with a maximum water-cementitious ratio of 0.45 and the cement content is set by the aggressive chemical exposure class, not by the fiber. Fibers are added at the batching plant onto the sand and coarse aggregate before binder, and mixing continues for 5 minutes in a compulsory paddle mixer or twin-shaft mixer. Polypropylene is thermally stable at the peak internal temperature of mass concrete, which is normally controlled below 70 °C by pre-cooled water or ice; the fiber does not alter the heat of hydration. End products such as breakwater armor units, outfall headwalls, intake channels, and sewer drop structures receive the fiber primarily for early-age surface crack reduction, while sulfate resistance remains governed by binder chemistry and water-cementitious ratio. The fiber is not a substitute for sulfate-resisting cement or pozzolanic additions, and it does not reduce the chloride penetration index measured by ASTM C1202-22 or the chloride migration coefficient measured by EN 12390-11:2015.

    Free Quote

    Competitive MasterFiber M 687 - Next-Generation Fibrillated Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber M 687 is classified as a next-generation fibrillated polypropylene fiber for hydraulic cementitious matrices. The product is supplied as a collated fibrillated bundle that opens into a three-dimensional network when exposed to normal concrete mixing shear. Under ASTM C1116/C1116M, the material falls within the Type III synthetic fiber category for fiber-reinforced concrete. Primary engineering intent is control of plastic shrinkage cracking and distribution of localized microcracking in slabs, pavements, precast units, wet-mix shotcrete, overlays, and repair mortars. It is not specified as a one-to-one substitute for primary structural reinforcement unless the structural design explicitly accounts for the fiber contribution. Published data for this specific configuration are limited outside the supplier batch certificate; where product-specific values are not published, class-typical fibrillated polypropylene data are used with explicit identification.

    Typical commercial documentation for this fiber class specifies a cut length of 19 mm, a density of 0.91 g/cm³, and water absorption below 0.1% under ASTM D570. The polypropylene base polymer exhibits a melt temperature of 160–170 °C under ISO 11357-3:2018. Tensile strength for oriented fibrillated polypropylene is typically 400–700 MPa under ISO 527-2:2012, with elongation at break 15–25%. These values are quality-control benchmarks for the fibrillated PP class and should be confirmed against the MasterFiber M 687 batch certificate.

    What Limits the Dispersed Fiber Count at High Addition Rates?

    Addition rate, rather than fiber count alone, controls the transition from plastic shrinkage crack suppression to measurable residual strength contribution. The working dosage window for a 19 mm fibrillated polypropylene fiber is commonly 0.9–1.8 kg/m³. Below 0.9 kg/m³, fiber distribution across a slab placement can become discontinuous, particularly when discharge time exceeds 45 min and fibers segregate near the top surface. Above 1.8 kg/m³, the limiting factor is not fiber saturation but water demand and entrapped air. Slump measured under ASTM C143/C143M may decrease by 20–40 mm at the upper boundary, and the air void system can shift by 0.5–1.0% unless the mix is re-engineered.

    The dispersed fiber count is governed by bundle opening efficiency rather than by fiber mass loading. In a 9 m³ twin-shaft compulsory mixer, sufficient shear is generated at 14–18 rpm during 60–90 s of post-fiber mixing. A free-fall drum mixer at the same dosage may require 90–120 s and can still exhibit balling when the drum is loaded above 75% of nominal capacity. The practical upper addition rate in any production unit is established by a washout test or visual inspection of the discharged slump sample, not by the fiber datasheet alone.

    When high addition rates are specified for crack control, the water-to-cement ratio should not be raised to compensate for slump loss. Instead, polycarboxylate ether superplasticizer is adjusted in increments not exceeding 0.1% by cement mass until the target slump is restored. A site trial under ASTM C1579-21 is required to verify plastic shrinkage crack reduction. MasterFiber M 687 cannot compensate for a deficient mix design or for inadequate finishing and curing.

    Fibrillated polypropylene differs from monofilament material because the bundle opens into a reticulated network under shear. This network increases mechanical anchorage within the cement paste and arrests plastic shrinkage cracks that propagate through the first 24 h after placement. The fibrillation process creates a higher effective surface area than smooth monofilaments of equivalent denier, which explains the slightly higher water demand at equal dosage. In field trials, the network is observed as a three-dimensional fibrous web in the plastic concrete; if the web is absent and individual filaments are discharging separately, the mixer shear is insufficient to open the bundles fully.

    Low-paste mixes with cementitious material below 300 kg/m³ create a specific processing conflict. The fibrillated network requires paste to coat the fibrils; without sufficient paste, the network remains partially exposed and can produce surface fuzzing under power trowel finishing. This is not a fiber defect but a paste-volume limitation. The addition of supplementary cementitious materials does not automatically correct this because fly ash and slag increase paste volume only when total cementitious content is raised. Silica fume at 5–8% by mass can improve coating but also increases water demand. Site trials under the specified finishing equipment are required.

    Parameter MasterFiber M 687 fibrillated PP Monofilament PP Steel fiber
    Material class Fibrillated polypropylene, ASTM C1116/C1116M Type III Monofilament polypropylene, EN 14889-2:2006 Class Ia Cold-drawn steel wire, ASTM A820
    Typical dosage 0.9–1.8 kg/m³ 0.6–1.0 kg/m³ 15–40 kg/m³
    Density 0.91 g/cm³ 0.91 g/cm³ 7.85 g/cm³
    Tensile strength 400–700 MPa 300–400 MPa 1000–1500 MPa
    Modulus of elasticity 3.5–4.8 GPa 3.0–4.0 GPa 200 GPa
    Primary function Plastic shrinkage crack control, secondary reinforcement Plastic shrinkage crack control Post-crack flexural toughness, structural substitution when designed
    Corrosion risk in chloride environments None None Present unless stainless or galvanized

    Values in the table reflect class-typical published data. MasterFiber M 687 batch certificates control product-specific values, and the comparison is not a substitute for project-specific qualification.

    When Fibrillated Polypropylene Replaces Welded Wire Mesh in Slab-on-Grade Placement

    In interior slabs on ground, the comparison between fibrillated polypropylene and welded wire mesh is specific to crack-control function, not structural load transfer. Welded wire reinforcement under ASTM A1064/A1064M provides defined yield strength and continuous bond; fibrillated polypropylene at 0.9–1.8 kg/m³ is non-structural in most design codes. Under ACI 360R-10, fibers may control initial shrinkage cracking but do not replace wire mesh for joint stability, load transfer at control joints, or structural flexural reinforcement. In a slab with truck traffic or heavy point loads, the fiber is not a substitute for steel reinforcing bars or dowels.

    Comparative batching under ASTM C1399/C1399M and ASTM C1609/C1609M can be used to measure residual flexural strength. For micro fibrillated PP at dosages below 1.8 kg/m³, the residual strength values are typically low, and published data for this specific configuration are limited. The fiber is therefore specified for plastic shrinkage crack reduction and not for post-crack flexural toughness. In applications such as residential slabs, parking lots, industrial floors, and shotcrete tunnel linings, the product is used to reduce early cracking; joint spacing, dowel placement, and slab thickness remain governed by structural design.

    For wet-mix shotcrete, fibrillated PP can reduce plastic shrinkage cracking and may reduce rebound, but pumpability trials are required because the opened fiber network can accumulate in sharp bends and reducers. Nozzle wear and air-loss characteristics should be evaluated with the specific pump type, usually a piston or rotor-stator gun operating at 50–80 bar outlet pressure. Published data for MasterFiber M 687 in this specific configuration are limited outside site-specific shotcrete qualifications. In pervious concrete with high void content, the use of fibrillated PP is not recommended because the open-graded aggregate matrix does not generate the paste shear required to open the bundle and the fiber can be lost through the void network.

    Relative to monofilament polypropylene, MasterFiber M 687 relies on fibrillated strand separation rather than discrete filaments. The opened network provides greater mechanical anchorage within the cement paste because the fibrils create a larger number of crack arrest points per unit mass. Relative to macro synthetic fibers, which are typically 38–60 mm long and dosed above 4 kg/m³, the product does not provide equivalent post-crack flexural toughness. Relative to steel fibers, the polymer fiber eliminates corrosion staining and magnetic disturbance, but its modulus is approximately 40–60 times lower, so it cannot compensate for primary tensile reinforcement. Under EN 14889-2:2006, the product is classified as a polymer fiber; microfiber and macrofiber categories are distinguished by diameter and performance class, not by raw material alone.

    Batch Sequencing and Shear Input Requirements for Ready-Mix Operations

    The addition sequence is critical for fibrillated fiber dispersion. In a central-mix batch plant, MasterFiber M 687 is charged after the coarse aggregate and 50–70% of the mixing water, but before the remaining water and chemical admixtures. This order allows the bundle to wet and open under aggregate shear without floating on the surface of the initial water. In a 9 m³ twin-shaft compulsory mixer, 60–90 s of additional mixing at full speed after fiber addition is sufficient; in a single-shaft mixer, 90–120 s may be required. The fiber should not be added as the first dry material onto the mixer blades because static charge and clumping can occur.

    For dry-batch truck mixing, the fiber may be pre-blended with aggregate before cement addition. The discharge time should be kept below 45 min when the dosage exceeds 1.2 kg/m³, because prolonged agitation can promote fiber flotation in high-slump mixes. Automatic fiber dispensers should be calibrated within ±5% of target mass, and manual bag additions should be recorded for each batch. The most common production failure is fiber balling caused by worn mixer blades or hardened concrete accumulation; clumps are visible in the slump sample and require mechanical mixer cleaning, not just extended mixing time.

    Fiber addition does not require pre-drying at relative humidity above 60%, because the polypropylene surface is hydrophobic and water absorption is below 0.1% under ASTM D570. However, storage should avoid temperatures above 50 °C and direct ultraviolet exposure. Bags that have been punctured or exposed to rain should be quarantined because surface contamination can alter fiber opening and create clumps.

    Quality documentation should include a batch certificate referencing EN 14889-2:2006, CE marking under the Construction Products Regulation (EU) No 305/2011, and REACH registration under EC 1907/2006. For North American projects, the supplier declaration usually confirms classification under ASTM C1116/C1116M and provides density, cut length, and tensile test data. The following matrix summarizes the test methods used for release of fibrillated polypropylene fiber of this class.

    Standard designation Parameter or characteristic Acceptance basis
    ASTM C1116/C1116M Type III synthetic fiber classification Supplier declaration, batch certificate
    EN 14889-2:2006 Polymer fiber properties and CE marking Notified body certification
    ISO 1183-1:2019 Density 0.905–0.915 g/cm³
    ISO 527-2:2012 Tensile strength and elongation at break 400–700 MPa, 15–25%
    ASTM D570 Water absorption 0.1% maximum
    ISO 11357-3:2018 Melt temperature 160–170 °C
    ASTM C143/C143M Slump retention after fiber addition Site trial target
    ASTM C1579-21 Plastic shrinkage cracking Crack reduction versus control panel

    Where project specifications require a different standard or additional testing, the batch certificate is not sufficient; a concrete trial using the actual mix design and placement equipment is mandatory.

    Alkali Resistance Does Not Imply UV Stability or High-Temperature Compatibility

    Polypropylene is resistant to the alkaline environment of portland cement, with no known degradation at the pH range 12.5–13.5 typical of concrete pore solution. This performance is independent of the cement type and is not improved by coating the fiber. However, alkali resistance does not translate to ultraviolet stability or high-temperature compatibility. Unprotected storage in direct sunlight or surface exposure of unmolded fiber bundles should be avoided because polypropylene undergoes photo-oxidative embrittlement. Bulk storage should be in closed, shaded conditions below 50 °C.

    The melt temperature of polypropylene is 160–170 °C under ISO 11357-3:2018. Sustained exposure above 150 °C can soften or fuse individual fibrils, which destroys the opened network and may create small polymer agglomerations in the concrete. Autoclave curing cycles in the 180–190 °C range are therefore outside the operational boundary for this product. Precast heat curing at 60–80 °C is within established practice, but sustained exposure at 90 °C has limited published data for this specific configuration.

    Chemical compatibility in concrete is broad; the fiber is inert to cement, silica fume, fly ash, slag, and common superplasticizers. It should not be exposed to strong oxidizing agents or organic solvents during storage. The product is insoluble in water and is not biodegradable; disposal should follow local plastics waste regulations. These boundaries are more restrictive than those for monofilament PP only in that the fibrillated network must remain mechanically opened to function, so thermal softening that only reduces filament stiffness in a monofilament can entirely eliminate the three-dimensional anchorage of a fibrillated product.