Liwei Group Co., Ltd

Products

SikaFiber 6 PPF - Micro Polymer Fiber

    • Product Name: SikaFiber 6 PPF - Micro Polymer Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 743534
    Productname SikaFiber 6 PPF - Micro Polymer Fiber
    Material 100% virgin polypropylene
    Fibertype Micro polypropylene fiber
    Form Fibers
    Color Natural
    Fiberlength 6 mm
    Fiberdiameter 0.018 mm
    Aspectratio 333:1
    Density 0.91 g/cm3
    Tensilestrength 350 MPa
    Elasticmodulus 3.5 GPa
    Meltingpoint 160 °C
    Ignitionpoint >350 °C
    Waterabsorption Nil
    Alkaliresistance Excellent
    Acidresistance Good
    Uvresistance Good
    Chemicalinertness Chemically inert
    Electricalconductivity Non-conductive

    As an accredited SikaFiber 6 PPF - Micro Polymer Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SikaFiber 6 PPF comes in 600 g water-soluble bags, packed 20 bags (12 kg) per carton for easy dosing.
    Container Loading (20′ FCL) 20′ FCL: SikaFiber 6 PPF micro polymer fiber, palletized sealed bags, loaded in dry container, evenly distributed, and safely secured.
    Shipping SikaFiber 6 PPF – Micro Polymer Fiber is typically shipped as a non-hazardous, non-DG material in moisture-resistant bags or cartons on pallets. Keep dry and avoid prolonged heat or ignition sources. Standard road, sea, or air freight applies; follow local regulations, SDS, and manufacturer guidance. No special temperature control required.
    Storage Store in original packaging in a cool, dry, well-ventilated area. Keep away from ignition sources, moisture, and incompatible materials. Protect from direct sunlight and temperature extremes. Keep containers sealed and palletized off the ground. Avoid excessive heat, sparks, and open flames. Rotate stock first-in, first-out. Follow manufacturer’s SDS and local regulations. Shelf life typically 24 months in unopened packaging.
    Shelf Life SikaFiber 6 PPF has a shelf life of 24 months from production when stored in original unopened packaging, dry, and protected from direct sunlight.
    Application of SikaFiber 6 PPF - Micro Polymer Fiber

    In ground-supported ready-mixed concrete for warehouse floor slabs, external hardstandings, and commercial vehicle pavements, SikaFiber 6 PPF is introduced during central batching at a dosage of 0.6–0.9 kg/m³ to limit plastic shrinkage cracking in the interval between strike-off and final set. The addition rate is selected against the anticipated bleed rate, surface evaporation rate, and the dimensional restraint imposed by formwork or doweled joints; at this dosage the fibre population is sufficient to bridge capillary menisci without producing measurable loss in slump beyond 20–40 mm at water–cement ratios between 0.45 and 0.55. Compliance for civil and industrial floors procurement is normally verified through EN 14889-2:2006 third-party conformity certification, with North American specifications referencing ASTM C1116/C1116M Type III synthetic fibre-reinforced concrete; plastic shrinkage behaviour is compared by restrained slab methods such as ASTM C1579-21, while fresh concrete acceptance remains under EN 206:2013+A1:2016 or ASTM C94/C94M. In production, the fibre is dispensed either by automatic bag-opening units at the mixer charging hopper or by fibre-dosing systems interlocked with aggregate weigh belts; direct discharge into high-velocity augers without pre-wetting is avoided because monofilament fibre bundles may segregate in low-moisture aggregates. The batching sequence places coarse aggregate, sand, and fibre into a twin-shaft paddle mixer for dry mixing of 30–45 seconds before the addition of cement, water, and admixture; total mixing time is extended by 15–30 seconds relative to plain concrete to disperse the fibres. Delivery is normally by standard truck mixer at 3–6 rpm agitating speed, with no more than 300 revolutions before discharge to limit fibre balling at the hopper screen. Placement on site uses laser-guided screeding machinery followed by power trowelling; the fibre does not impair pan float finish when the trowel blade angle is advanced after bleed has ceased. Terminal finished products include jointed ground-bearing floor slabs in logistics warehouses, racking aisles with flatness tolerances checked under DIN 18202, external apron slabs, fuel-station forecourts, and rural hardstandings. The operational boundary is explicit: SikaFiber 6 PPF is not a substitute for structural steel reinforcement, dowel bars, or armoured joints, and it is not specified where post-crack residual flexural capacity is required under imposed load.

    What Limits Early Demoulding of Dry-Cast Non-Structural Precast Concrete?

    Polypropylene micro fibre dosing in dry-cast and zero-slump precast concrete is concentrated on edge preservation and green-strength demoulding rather than hardened structural toughness. For cable troughs, socketed pipes, manhole rings, concrete blocks, agricultural slatted floors, and retaining-wall segments, the addition rate is typically 0.6–1.2 kg/m³ of concrete; the upper bound is constrained by reduced compaction response in dry-cast mixes when fibre content rises above 1.5 kg/m³, at which point vibration energy transfer becomes non-uniform and mould corners may show porosity. Product compliance is evaluated under EN 13369:2008 common rules for precast concrete, specific product standards such as EN 1916:2002 for concrete pipes and EN 14889-2:2006 for polymer fibre conformity; North American precast drainage products may be tested under ASTM C76 or ASTM C1479 where applicable. The production process integrates the fibre at the pan mixer stage: aggregate and fibre are dry-blended for 30 seconds before cement and water are added, and the total cycle time is controlled because dry-cast mixes have moisture contents between 5% and 8% by mass. After mixing, the zero-slump concrete is transported to the casting station by skip hoist or conveyor; the concrete is placed into steel moulds and consolidated by high-frequency external vibration. Demoulding of pipe and manhole segments at green strength is possible only when the micro fibre suppresses crack initiation at sharp corners and handling stresses; published data for this specific dry-cast configuration is limited, so site trials are required to confirm the optimum dosage for the mould geometry. Surface finishes remain compatible with water-based concrete release agents, and fibre protrusion at formed surfaces is generally minimal at dosages below 1.0 kg/m³. The addition should not be used to replace conventional curing compounds in products exposed to rapid surface moisture loss during steam curing; the fibre acts during the plastic phase only. Terminal finished product types include non-pressure concrete pipes, stormwater culvert segments, cable troughs, interlocking paving blocks, masonry units, slatted flooring elements, and precast retaining-wall segments.

    Wet-Mix Shotcrete Lining Pressures and Early-Age Crack Control in Underground Excavations

    In wet-mix shotcrete for primary tunnel lining, SikaFiber 6 PPF is dosed into the truck mixer at the batching plant at 0.9 kg/m³ to 1.5 kg/m³, depending on the ground support class, early-age curing conditions, and accelerator chemistry. The fibre is dispersed before the air-entraining and water-reducing admixture package because late introduction into a pressurised wet-mix line can produce fibre agglomerates at the pump hopper. Spraying is performed with a positive-displacement concrete pump or pneumatically assisted wet-mix machine, at a nominal line pressure of 20–80 bar, with a nozzle distance between 0.6 m and 1.2 m from the substrate. The addition of a liquid alkali-free set accelerator at the nozzle at 3–8% by mass of cement is compatible with the micro fibre; the fibre does not contribute to rebound in the same way as rigid steel fibre, but rebound rates must still be controlled by mix cohesion and nozzle angle. The key process conflict is the interaction between the fine-fibre population and high-early-strength accelerator: at dosages above 1.8 kg/m³ the plastic viscosity may increase to the point where pump stroke efficiency drops and blockages occur in 50 mm delivery lines; for that reason the upper dosage is set at 1.5 kg/m³. Lining installation is carried out in layers of 50–100 mm per pass, with the fibre controlling plastic shrinkage in the exposed surface before the next pass. Terminal products are permanent and temporary shotcrete linings in road tunnels, metro stations, rock slope stabilisation, cut-and-cover retaining walls, and swimming pool shells where spray-applied concrete is used as the primary lining.

    Verification of wet-mix shotcrete containing SikaFiber 6 PPF is performed against the following conformity checks.

    Verification parameterStandard / methodPPF-related control observation
    Polymer fibre conformityEN 14889-2:2006Non-structural polymer fibre classification for plastic shrinkage control
    Fresh sprayed concrete workabilityEN 12350-2:2019Slump loss controlled within 20–40 mm at ≤1.2 kg/m³
    Plastic shrinkage cracking resistanceASTM C1579-21Reported crack area reduction of 40–80% at 0.9 kg/m³ in restrained slab testing
    Sprayed concrete compressive strengthEN 14488-2:2006No significant strength change at ≤1.5 kg/m³

    The product is not a structural fibre and cannot replace steel fibre or welded wire mesh when the design specifies post-crack flexural energy absorption under EN 14488-3:2006 or ASTM C1609/C1609M. Pumping lines should be cleaned after each shift; fibre residue in reducing sections has been observed to accelerate blockages when mortar temperature exceeds 30 °C.

    Cementitious self-levelling underlayments and bonded screeds produced with silo-mixed binders require early plastic-phase crack control when the installed layer thickness falls below 40 mm and when underfloor heating pipes create an irregular section. SikaFiber 6 PPF is incorporated at 0.6–1.0 kg/m³ of mixed screed to reduce plastic-phase crack development over heated floors, old concrete substrates, and variable-thickness sections between 20 mm and 50 mm. Compliance for screed materials is assessed under EN 13813:2002, which designates strength classes and wearing suitability, while flexural and adhesion testing follows EN 13892-2:2002; fibre conformity is certified separately under EN 14889-2:2006. In production, the fibre is pre-blended into the dry binder in a continuous silo mixer or added with the first water fraction in mobile mixing pumps. The mixed material is pumped through 25–50 mm internal-diameter hoses to the placement area, where it is spread with a gauge rake, smoothed with a smoothing trowel, and de-aerated with a spike roller before final levelling. The insertion of a fibre population during mixing raises plastic viscosity slightly, so the water demand at a given flow diameter may need to be adjusted within the manufacturer's maximum water–binder ratio; excessive additional water to restore flow may increase segregation and must be avoided. The fibre does not provide crack-bridging on moving joints, shrinkage joints, or structural cracks, and it does not reduce drying shrinkage once the matrix has hardened; therefore conventional drying-shrinkage control, substrate priming, and movement joints remain mandatory. Terminal finished product types include pump-applied self-smoothing underlayments under vinyl, LVT, and ceramic tile, bonded cementitious wearing screeds in renovation projects, floor levelling layers over underfloor heating systems, and cementitious separating layers where appropriate. In areas subject to moisture-sensitive floor covering, residual moisture limits from the adhesive manufacturer remain binding.

    When PPF Is Introduced into Factory-Blended Dry Mortars and Concrete Repair Products

    Factory-blended dry mortars and concrete repair products are corrected with SikaFiber 6 PPF at a target addition ratio of 0.6–1.2 kg/m³ of mixed mortar; the corresponding dry-batch weight is calculated from the mortar yield and must be fixed after laboratory trials. Compliance is anchored to EN 1504-3:2005 for structural repair mortars, EN 998-1:2016 for rendering and plastering mortars, and ASTM C928/C928M for packaged dry concrete repair sold in North America. The downstream production process is a batch dry-mixing operation: the fibre is first opened by a high-speed plow mixer to avoid balling before being blended with cement, graded silica sand, polymer binder, and powdered admixtures for a cycle time of 3–6 minutes. The critical process constraint is the moisture content of the dry blend; fibre addition into a mixer with residual moisture above 0.3% can lead to agglomeration at bagging screws and blocking of the packing spout. After blending, the material is discharged into valve bags or big bags, and the fibre is distributed homogeneously as a discrete phase. On the application site, the repair mortar is mixed with a prescribed water volume in a forced-action paddle mixer for 2–3 minutes, applied by trowel or spray, and finished with a float. The fibre contributes to plastic cracking resistance in patch edges and around embedded steel, but it is not a corrosion inhibitor and does not alter cathodic protection design; substrates still require mechanical preparation, and reinforcing steel must be primed or coated according to the repair specification. Terminal finished products include pre-bagged concrete repair mortars for spall repair, polymer-modified filling compounds, external rendered façade mortars, and dry-mix concrete for small non-structural castings. The material should not be used in acid-resistant or chemically aggressive overlays, and its effectiveness in fire-rated repair systems should be verified under EN 13501-1 before specification.

    Free Quote

    Competitive SikaFiber 6 PPF - Micro Polymer Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    SikaFiber 6 PPF - Micro Polymer Fiber is a virgin polypropylene monofilament microfibre supplied in 0.9 kg water-soluble bags for direct addition to concrete, mortar, and shotcrete. The product is assigned to ASTM C1116/C1116M Type III synthetic fibre-reinforced concrete and EN 14889-2:2006 Class I polymer fibre; the classification identifies the material as a micro-scale synthetic fibre intended for plastic-phase crack control rather than hardened structural reinforcement. The published nominal fibre length is 6 mm, with a diameter of 18 µm and a calculated aspect ratio of 333.

    The table below consolidates the manufacturer-published physical parameters used for mix design, batching control, and specification compliance.

    Parameter Reference or test method Published value
    Fibre length Manufacturer published data 6 mm
    Fibre diameter Optical microscopy 18 µm
    Aspect ratio Calculated length/diameter 333
    Specific gravity ASTM D792 0.91
    Tensile strength ASTM D2256 320 MPa
    Elastic modulus ASTM D638 3.5 GPa
    Melting point Differential scanning calorimetry 162 °C
    Water absorption 24 h immersion None measurable
    Packaging Water-soluble bag 0.9 kg
    Standard addition rate Manufacturer recommendation 0.9 kg/m³

    The fibre functions by increasing the tensile strain capacity of the cement paste before setting. When evaporative loss exceeds bleed-water migration, capillary menisci form between near-surface particles and generate negative pore-water pressure; the fresh matrix cracks when the induced tensile stress exceeds the low early tensile capacity of the paste. Monofilament polypropylene fibres intersect the growing microcracks at a high number of discrete locations. Crack extension requires either fibre pullout or fibre deformation. The resistance to pullout is controlled by the fibre-matrix contact area and by the local water-to-cementitious ratio at the fibre surface. Because the elastic modulus of the fibre is 3.5 GPa, the material does not carry significant stress after the matrix hardens and is not a substitute for deformed reinforcing bars, welded wire fabric, or macro-synthetic fibres.

    In ready-mix production, the product is introduced to a 9.1 m³ truck mixer after aggregates, cementitious materials, and approximately 80% of the batch water are charged. Drum speed is maintained at 12–15 rpm for 70–100 revolutions after fibre addition. Cold batch water below 5 °C prolongs dissolution of the water-soluble packaging and may require an extended mixing cycle; discharge before complete bag dissolution and fibre separation has been observed at plant and site operations as residual fibre bundles on screeded surfaces. Preconstruction trial batching should verify fresh concrete behaviour in accordance with ASTM C143/C143M-20 for slump retention and ASTM C1611/C1611M-21 for pumpability where high-range water-reducing admixtures are present.

    What Distinguishes a Micro Synthetic Fibre from Steel and Macro-Synthetic Fibre Classes?

    Difference from other products is defined primarily by fibre geometry, material density, elastic modulus, and the resulting function in the concrete section. Steel fibres conforming to ASTM A820/A820M are typically used at 15–40 kg/m³ and provide post-crack residual flexural capacity because steel has a density of 7.85 g/cm³ and an elastic modulus near 200 GPa. Macro-synthetic fibres conforming to EN 14889-2:2006 Class II are typically used at 3–8 kg/m³ and provide moderate post-crack capacity through pullout resistance developed over lengths generally between 38 mm and 54 mm. SikaFiber 6 PPF - Micro Polymer Fiber is used at 0.9 kg/m³ and does not produce a measurable post-crack residual flexural response under ASTM C1399/C1399M-10a; its function is plastic-shrinkage crack reduction before initial set, evaluated in comparative restrained slab testing under ASTM C1579-21.

    The table below compares representative industrial ranges for material selection. Values are general ranges, not project specifications; final dosage and expected performance must be established by trial batching and preconstruction testing.

    Parameter SikaFiber 6 PPF - Micro Polymer Fiber Steel fibre, ASTM A820/A820M Macro-synthetic fibre, EN 14889-2:2006 Class II
    Material density 0.91 g/cm³ 7.85 g/cm³ 0.91–0.95 g/cm³
    Nominal length 6 mm 30–60 mm 38–54 mm
    Typical dosage 0.9 kg/m³ 15–40 kg/m³ 3–8 kg/m³
    Primary function Plastic-shrinkage crack control Post-crack flexural capacity Post-crack flexural capacity and crack-width control
    Corrosion behaviour Non-corroding Surface staining possible without cover Non-corroding
    Minimum cover for corrosion Not required Required per ACI 544.4R Not required
    Post-crack residual strength Not measurable at standard dosage Significant Moderate

    The absence of a minimum cover requirement for polypropylene fibres does not eliminate cover requirements for reinforced concrete. Cover to embedded steel reinforcement remains governed by ACI 318 or the applicable concrete design code. The microfibre does not alter the structural capacity of a composite metal deck slab, does not replace welded wire fabric in slabs on ground, and does not remove the need for sawcut joint layout or curing. It is specified in conjunction with a wet cure or a membrane-forming curing compound conforming to ASTM C171. Without adequate curing, hardened drying shrinkage cracking can occur independently of the fibre addition.

    Once fibre dispersion is delayed past the mixing window, surface finishing defects increase

    Production-scale failure modes observed with this fibre class are dominated by timing errors during addition, mixing, and early finishing. Introduction of the bags into dry aggregates before water has been charged can produce electrostatic fibre entanglement and clumps that do not break down under subsequent low-shear truck mixing. Discharge at the site before the minimum 70–100 revolutions after addition may leave water-soluble film remnants and undispersed fibre bundles in the mix. During hard steel trowelling, these bundles can migrate to the surface and create visible fibre clusters. Extended finishing with wet blades over fibre-reinforced concrete can raise surface fibre nap; the standard corrective measure is a power trowel fitted with float blades, with final hard trowelling delayed until the surface has stiffened sufficiently to prevent fibre pull-up.

    Where the same 0.9 kg/m³ dosage is used in self-consolidating concrete with slump flow above 550 mm under ASTM C1611/C1611M-21, fibre distribution may become inhomogeneous because the low yield stress allows fibre clusters to move as localised inclusions. A preconstruction test panel and possible adjustment of mixer energy or charging sequence are required for this configuration. Compatibility with polycarboxylate ether superplasticisers should also be validated in the trial mix because localised changes in paste viscosity can affect fibre mobility and surface finish. Published data for this specific product configuration is limited, so performance claims should not be extrapolated without project-specific testing.

    Shotcrete and precast placement boundaries

    In dry-process shotcrete, the product is metered into the dry mix stream at the nozzle or added at the bagging plant. In wet-process shotcrete, it is batched into the mixer before pumping. The same 0.9 kg/m³ addition rate is used unless rebound measurements justify a higher rate. Low fibre mass and high surface area may alter rebound behaviour in dry-process applications; trial spraying under project-specific nozzle conditions is required to establish the rebound ratio and in-place fibre content. In precast concrete, external high-frequency vibration should be evaluated on the production line. Polypropylene fibre has low mass and may follow the vibrating form at high frequencies; published data for this specific configuration is limited, and a plant trial is the only reliable method to confirm surface distribution.

    For mortar and stucco, the fibre is added at the same volumetric ratio or adjusted for the lower coarse-aggregate content. The product is non-corroding in alkaline cement pore solution at pH 12.5–13.5 and does not degrade under normal exposure to chloride ion, sulfate solution, or carbon dioxide. It does not mitigate alkali-silica reaction, sulfate attack, or corrosion of embedded steel; those durability mechanisms require independent material controls and concrete cover provisions. Because the melting point is 162 °C, the fibre may melt under fire exposure and create small void channels. The standard addition rate of 0.9 kg/m³ is not necessarily sufficient for fire spalling mitigation; passive fire-resistance concretes often specify higher polypropylene fibre dosages, typically 1.5–3.0 kg/m³, and require furnace testing under the relevant fire curve.

    Storage of the water-soluble bags requires dry conditions and protection from direct UV exposure. The product is not intended as primary reinforcement, does not replace structural steel in flexural members, and must not be used to justify reduction in design crack-control reinforcement unless a project-specific performance specification has been validated by a qualified engineering review.