    • Product Name: Fibermesh 650 - Macro & Micro Hybrid Synthetic Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 422707
    Product Type Macro & Micro Hybrid Synthetic Fiber
    Material Composition 100% virgin polypropylene
    Fiber System Hybrid macro and micro synthetic fibers
    Macro Fiber Length 1.5 in (38 mm)
    Micro Fiber Length 0.5 in (12 mm)
    Tensile Strength 90,000 psi (620 MPa)
    Elastic Modulus 1,300,000 psi (9 GPa)
    Melting Point 320°F (160°C)
    Ignition Point 590°F (310°C)
    Water Absorption Nil
    Alkali Resistance Excellent
    Acid Resistance Excellent
    Salt Resistance Excellent
    Typical Dosage 4.5 lb/yd³ (2.67 kg/m³)
    Packaging 5 lb (2.27 kg) bag
    Compliance ASTM C1116 Type III; ASTM C1602

    As an accredited Fibermesh 650 - Macro & Micro Hybrid Synthetic Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Fibermesh 650 Macro & Micro Hybrid Synthetic Fiber packaged in 20 kg moisture-resistant paper sacks, palletized and shrink-wrapped.
    Container Loading (20′ FCL) 20′ FCL container loading: Fibermesh 650 macro/micro hybrid synthetic fiber in moisture-resistant bags, palletized, shrink-wrapped, and secured for export.
    Shipping Fibermesh 650 – Macro & Micro Hybrid Synthetic Fiber is typically shipped as a non-hazardous, non-regulated article. It is packaged in moisture-resistant bags or cartons on pallets. Store dry, away from ignition sources, and handle with normal PPE. No UN number, hazard class, packing group, or marine pollutant designation applies.
    Storage Store Fibermesh 650 in a cool, dry, well-ventilated area, off the floor on pallets. Keep original packaging sealed, upright, and protected from moisture, direct sunlight, heat, flames, and contaminants. Avoid puncturing bags. Store away from acids, solvents, and strong oxidizers. Maintain good housekeeping, follow the manufacturer’s SDS, and use stock rotation to prevent damage.
    Shelf Life Typically indefinite when stored dry, in original unopened packaging, away from moisture, direct sunlight, and extreme temperatures.
    Application of Fibermesh 650 - Macro & Micro Hybrid Synthetic Fiber
    Placement of Fibermesh 650 in large-format slab-on-ground construction is typically specified with a 28-day compressive strength range of 25 MPa to 40 MPa where the design intent is to delete welded wire mesh from the upper third of the slab section and reduce plastic shrinkage cracking during the first 6–12 hours after finishing. The addition rate used on warehouse and logistics floor slabs is commonly 2.5 kg/m³ to 4.0 kg/m³; rates below 2.0 kg/m³ have not consistently produced the required post-first-crack residual strength in published laboratory comparisons, and trial slabs tested under ASTM C1399/C1399M-10(2015) are required to establish the acceptance envelope. The concrete is batched in a central mixer with dry fiber sacks discharged into the aggregate stream or introduced after water stabilization, followed by a post-fiber mixing interval of at least 90 seconds at high shear. Slabs are placed by laser-guided screed, vibrated with low-frequency immersion units, and troweled only after bleed-water sheen has cleared; premature troweling traps bleed water and produces surface delamination, while delayed troweling allows macro fiber ends to protrude and creates a fuzzy surface. Compliance documentation for warehouse slabs commonly references ASTM C94/C94M-23, ASTM C1116/C1116M-23 Type III fiber-reinforced concrete, ACI 302.1R-15, ACI 360R-10, and flatness/levelness measurement under ASTM E1155/E1155M-20. Joint saw cutting is performed between 8 hours and 24 hours after final finishing, and a curing compound meeting ASTM C309-19 is applied to control slab curl; the hybrid fiber system does not alter bleed rate or replace the specified curing regime. Terminal product types include high-bay third-party logistics warehouses, cold storage floor slabs, automotive assembly halls, and air-cargo cross-dock facilities where specified flatness values above FF 40 are common.

    Why Are Hybrid Macro-Micro Synthetic Fibers Specified for Wet-Mix Underground Linings?

    In wet-mix shotcrete and precast segmental lining applications, the macro fraction of Fibermesh 650 is retained across the nozzle and around the reinforcement cage while the micro fraction contributes to early-age plastic shrinkage crack control before accelerator flash setting closes the surface. European conformity for polymer fibers in structural sprayed concrete is assessed under EN 14889-2:2006; sprayed concrete specification follows EN 14487-1:2005 and guidance in EFNARC 1996, with North American shotcrete practice aligned to ACI 506R-16. Addition rates for wet-mix shotcrete range from 2.5 kg/m³ to 4.5 kg/m³; precast tunnel segment mixes typically dose between 3.0 kg/m³ and 5.0 kg/m³ to meet post-crack performance verified by ASTM C1609/C1609M-19a or ASTM C1399/C1399M-10(2015). Production on tunnel segments uses 50–70 Hz external vibration on steel moulds, immediate lift-off after compaction, and steam curing at 55–70 °C to reach demolding strength; wet-mix shotcrete is conveyed by twin-piston pump and sprayed robotically with nozzle distance maintained at 0.8–1.2 m from the substrate. Field observation indicates that fiber balling at pump reducers becomes more likely when the macro fiber addition exceeds 5.0 kg/m³ and the line includes more than two 90° bends; published data for this specific equipment configuration is limited, so pump pressure and rebound are monitored during trial spraying. The terminal product types include precast concrete tunnel lining segments, shaft collar frames, adit portal walls, and sprayed primary tunnel linings.

    Precast Drainage and Utility Structure Release Properties and Fiber Dosing Windows

    Dry-cast pipe and box culvert production introduces Fibermesh 650 at 1.8 kg/m³ to 3.5 kg/m³ to reduce handling cracks before steam curing and to improve intactness at demolding without raising water demand beyond the 0.32–0.38 water-cement ratio typical of dry-cast pipe mixes. The manufacturing route consists of zero-slump concrete discharged into vertical or horizontal moulds, consolidated by 45–65 Hz external vibrators, followed by immediate demolding once the green strength reaches approximately 0.2 MPa to 0.5 MPa; the macro fiber phase can protrude at the outer pipe surface if vibration continues beyond the specified cycle, and the surface is dry-finished by rotating trowel or belt finisher. Compliance standards commonly referenced include ASTM C478-23 for precast reinforced concrete manhole sections, ASTM C76-23 for reinforced concrete culvert, storm drain, and sewer pipe, EN 1916:2002 for concrete pipes and fittings, and ASTM C497-20 for testing of concrete pipe and tile. Fiber reinforcement in such products is evaluated for conformity to EN 14889-2:2006 where European harmonized marking is required. The material should not be used as primary reinforcement for pipe classes designed with steel cage or cage-and-elliptical reinforcement under ASTM C76-23 unless the engineering design explicitly accounts for synthetic fiber tension capacity. The terminal product types include reinforced concrete pipe classes III through V, box culvert sections, manhole risers and cones, catch basins, and headwalls.Because reach stacker and straddle carrier movements in container yards generate repeated flexural cycles at slab edges, the concrete mix is proportioned with Fibermesh 650 at 2.8 kg/m³ to 4.5 kg/m³ to provide residual flexural capacity after initial cracking and to reduce uncontrolled thermal shrinkage cracking between saw-cut joints. Trial slabs are tested under ASTM C1609/C1609M-19a at 7 days and 28 days to establish load-deflection response; acceptance criteria typically require a minimum residual strength at net deflection of L/600 that is not less than 15% of first-peak flexural strength. Placing equipment on such hardstands includes a laser-guided track screed or a slipform paver for long straight aprons, immersion vibrators with 25–40 mm head diameter, dowel baskets fixed at construction joints, and early joint saw cutting at 6–12 hours to prevent random cracking. A cure-and-seal compound meeting ASTM C309-19 is applied after final finish to retain moisture and harden the surface, followed by joint sealing under ASTM C920-18. Joint spacing beyond 6 m requires dowel load transfer regardless of fiber dosage; the macro-micro hybrid system is not a replacement for dowels or tie bars. The terminal product types include container terminal pavements, intermodal rail sidings, airport apron hardstands, and bus rapid transit stations.

    When Welded Wire Mesh Is Eliminated From Composite Metal Deck Slabs

    On steel-framed floors with cold-formed metal deck, welded wire mesh is sometimes deleted from the topping slab when the specified crack-control reinforcement is redefined as a synthetic fiber system. Fibermesh 650 is added at 1.8 kg/m³ to 3.0 kg/m³ in a concrete mix with a slump of 150–180 mm and 28-day strength of 28–35 MPa; the fibers are introduced at the ready-mix plant after initial water addition and mixed for 60–90 seconds before discharge. Placement on composite deck employs pump discharge and a mechanical oscillating screed, with the deck profile height commonly 76 mm or 81 mm and the specified slab cover above flute crest not less than 65 mm. The design is governed by SDI C-2017, AISC 360-22, and ASTM C1116/C1116M-23 Type III fiber-reinforced concrete, with flexural toughness verification performed under ASTM C1609/C1609M-19a. The composite deck slabs are poured in long strips to reduce cold joints, with a wet-cure or sheet-cure period of 7 days where ambient relative humidity falls below 60%; high-slump mixes containing fibers may show surface fiber visibility if the final trowel pass is made after the paste begins to stiffen. Negative moment regions over structural steel girders generally require supplemental top reinforcing bars because the fiber system is not intended to replace continuous longitudinal steel in composite beam design. The terminal product types include office tower floor slabs, hospital deck placements, data-center raised-floor support slabs, and multi-family corridor decks.

    Precast architectural concrete faces require controlled crack bridging at low cover depths

    Architectural precast facade production uses Fibermesh 650 in the face mix at 1.5 kg/m³ to 3.0 kg/m³ to limit surface map cracking and to maintain panel geometry after acid etching or retarded washing exposes the aggregate. The face mix is composed with 10 mm maximum aggregate, 0.35–0.45 water-cement ratio, and a high-range water reducer to keep slump below 100 mm; the backup mix is placed after the face mix has stiffened sufficiently to resist displacement, typically when a 50–100 mm slump differential is recorded by EN 12350-2:2019. The two layers are consolidated by high-frequency external vibration on a tilt table at 50–80 Hz, steam cured at 55–70 °C to accelerate form turnaround, and then subjected to retarder application and pressure washing to expose the face at a controlled depth of 1.0–1.5 mm. Compliance for such panels typically references ASTM C1116/C1116M-23 Type III, EN 14889-2:2006 for polymer fibers, ASTM C666/C666M-15 for freeze-thaw resistance, and ASTM E84-23 for surface burning characteristics where the building code requires. Fiber visibility on exposed aggregate surfaces may occur if the coarse aggregate size exceeds 12 mm or if the retardation depth exceeds 1.5 mm; trial panel approval is therefore conducted before production batches are released. The terminal product types include ventilated facade panels, spandrel panels, load-bearing architectural precast walls, and acoustic barrier units.
    Free Quote

    Competitive Fibermesh 650 - Macro & Micro Hybrid Synthetic Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Fibermesh 650 is a macro/micro hybrid synthetic fibre system for concrete and cementitious matrices. The model designation identifies a two-fraction polypropylene fibre package composed of a macro-monofilament fraction and a fibrillated micro-fibre fraction. The macro fraction is engineered to bridge post-crack surfaces and maintain residual flexural capacity, while the micro fraction is dispersed at high surface area to interrupt bleed-water channels and capillary tensile stress during the plastic state. Manufacturer-published specification values for the virgin polypropylene resin include a specific gravity of 0.91 when tested in accordance with ASTM D792-20, a tensile strength of approximately 620 MPa under ASTM D638-14, and an elastic modulus near 3.5 GPa. The product is intended for dosage rates between 1.5 kg/m³ and 4.0 kg/m³, corresponding to approximately 2.5 lb/yd³ through 6.7 lb/yd³ in ready-mixed concrete. Compliance is stated against ASTM C1116/C1116M Type III for synthetic fibre-reinforced concrete. The data below summarise the product specification profile.

    Fibermesh 650 specification profile
    ParameterTypical valueReference standard
    Polymer composition100% virgin polypropylene—
    Specific gravity0.91ASTM D792
    Tensile strength620 MPaASTM D638
    Elastic modulus3.5 GPaASTM D638
    Nominal dosage range1.5–4.0 kg/m³—
    Concrete fibre classificationType III synthetic fibreASTM C1116/C1116M
    European fibre classificationPolymer fibreEN 14889-2:2006

    The product is used in ready-mixed concrete for interior and exterior slabs-on-grade, industrial floors, composite steel deck, pavements, and precast concrete elements. It is specified where both early-age plastic shrinkage control and hardened-state residual flexural capacity are required in the same concrete mixture. The material is not used as a direct replacement for conventional deformed-bar reinforcement in primary structural members.

    What Separates Plastic-State Crack Control from Hardened-State Toughness?

    The micro-fibre fraction operates primarily before final set. In restrained slab sections, capillary pressure generated by menisci in bleed-water channels can exceed early-age tensile capacity; the fibrillated polypropylene filaments reduce the connectivity of these channels and provide local crack arrest. Performance in this phase is evaluated by ASTM C1579-21, which uses a restrained panel with a steel form insert to induce cracking under controlled evaporation. The test measures crack-width reduction relative to plain concrete; fibre effectiveness is reported as the average crack width ratio at a defined exposure period. Published data for this specific product configuration in ASTM C1579-21 is limited, but the micro-fraction mechanism is well documented for fibrillated polypropylene systems.

    The macro-fraction operates after matrix cracking. When a crack propagates through the cementitious matrix, the macro-monofilament is pulled across the fracture plane. Residual tensile load is transferred through interfacial shear until fibre pull-out or rupture. The post-crack response is typically characterised by ASTM C1399/C1399M, in which residual strength is computed from load-deflection data at net deflections of L/300 and L/150, or by ASTM C1609/C1609M, which reports first-peak strength and residual strengths at net deflections of L/600 and L/150. The hybrid architecture therefore addresses two separate cracking regimes: the plastic shrinkage window, where micro-fibre surface area is the dominant variable, and the hardened post-crack window, where macro-fibre length and anchorage control load retention.

    The transition between these regimes is not linear with dosage. At addition rates below 1.5 kg/m³, the macro fraction is insufficient to bridge a statistically uniform crack network in a 150 mm thick slab; micro-fibre action may still reduce plastic shrinkage cracking, but post-crack residual strength falls sharply. In industrial floor slabs specified for post-crack residual strength of not less than 0.50 MPa at L/300 under ASTM C1399/C1399M, a dosage near 3.0 kg/m³ is commonly selected. The transition is governed by macro fibre count per unit volume; lower dosage reduces the crack-bridging probability across a random crack plane.

    When Batching Sequence Deviates from the Fibre-Dosing Protocol

    Fibre dispersion is controlled more by batching sequence than by total mixing time in ready-mix operations. In a twin-shaft compulsory mixer with a batch volume greater than 2.0 m³, the fibre package is introduced after the aggregate fraction and before the cement slurry reaches full fluidisation. If the fibres are charged into a drum transit mixer with water first, the polypropylene strands can float and form raft-like clumps; if charged after high-range water-reducing admixture has reduced yield stress below 5 Pa, the macro fibres may not separate under low shear. Production-line observations on a 2.5 m³ twin-shaft mixer show that fibre clump incidence increases when the package is added directly to wet paste; clumps are typically 10–30 mm in diameter and are not dispersed by the remaining mixing cycle.

    The recommended sequence observed on production lines is to add the fibre package to the aggregate stream on the charging conveyor, then discharge the remaining powders and water. In truck-mixed concrete, the drum speed should be maintained above 15 rpm during fibre introduction, with an additional 4–6 min at full mixing speed. Mixing longer than 12 min at high shear may degrade the fibrillated micro-fibre structure and reduce the specific surface area required for plastic-state control. Slump loss at 3.0 kg/m³ is typically 10–20 mm under ASTM C143/C143M; this is compensated by adjusting the high-range water-reducing admixture rather than adding water beyond the mix design. The product does not require pre-drying because polypropylene absorbs water at less than 0.1% by mass, but wet packaging stored above 60% relative humidity can produce surface clumping that blocks automated fibre-dosing units.

    In slab-on-grade placements using a laser-guided screed and ride-on power trowels, the fibre system alters the timing of final finishing. The macro fraction remains below the trowel path if initial floating is completed before the macro fibres begin to protrude; delayed final finishing after the surface paste has stiffened can pull fibres across the finished surface. The correct sequence is initial strike-off followed by floating, then final trowelling after the bleed water has disappeared but before the macro fibre tips lose embedment. Curing under ASTM C171 remains the controlling factor for moisture retention; fibre addition does not eliminate the need for membrane-forming curing compounds or wet curing in hot weather.

    In composite steel deck applications, the hybrid system is introduced at the plant, not on site. Avoid adding fibres directly to a pump hopper as a substitute for plant batching because distribution is not reliable. The deck concrete should be placed with a pump line reducer no smaller than 100 mm and a discharge height not exceeding 1.5 m to minimise macro fibre clustering. These constraints are operational observations; published data specific to Fibermesh 650 in metal deck concrete with different deck geometries is limited.

    Comparative Performance Against Single-Fraction Fibre and Steel Fibre Reinforcements

    Fibermesh 650 differs from single-length micro-only synthetic fibres in that the micro-only product controls plastic shrinkage but contributes negligible post-crack residual strength. It differs from macro-only synthetic fibres in that the macro-only product can improve post-crack toughness but may leave plastic-state cracking insufficiently controlled if the fibre count per unit volume is low. Steel fibres provide a higher elastic modulus of approximately 210 GPa and a density near 7.85 g/cm³, which yields greater post-crack residual strength at equivalent dosage. However, steel fibres introduce corrosion risk in cracked concrete and cannot be used where electromagnetic interference or rust staining is prohibited. Fibermesh 650 is non-corrosive, with a specific gravity of 0.91, and therefore avoids surface rust discolouration. The trade-off is a lower elastic modulus; glass fibre or steel fibre systems may be required when the service stress exceeds the synthetic fibre anchorage capacity.

    Compared with glass-fibre systems, polypropylene is stable in alkaline concrete pore solution without a sizing that resists calcium hydroxide attack. E-glass fibres require a zirconia content above 16% to provide adequate alkali resistance; this requirement does not apply to the polypropylene hybrid. Compared with cellulose or natural fibres, polypropylene does not absorb water and does not rot, but it also does not provide the same hydrophilic bonding surface unless the fibre is surface-treated. The table below summarises comparative attributes.

    Comparative performance matrix
    Fibre systemPlastic shrinkage controlPost-crack residual strengthDensityCorrosion risk
    Fibermesh 650 hybridHighModerate0.91 g/cm³None
    Micro-only fibrillated polypropyleneHighLow0.91 g/cm³None
    Macro-only monofilament polypropyleneModerateModerate0.91 g/cm³None
    Steel fibreModerate to lowHigh7.85 g/cm³Present

    The comparative matrix is categorical; project-specific residual strength values must be obtained from ASTM C1399/C1399M or ASTM C1609/C1609M panels cast with the actual concrete mixture. Published data for this specific product configuration in direct comparison to steel fibres across all exposure classes is limited.

    Maintaining Fibre Homogeneity During Pumped Placement

    Pumping imposes shear and pressure conditions that can affect fibre orientation and distribution. In a boom pump with a minimum line diameter of 100 mm and a pulsation frequency near 25–30 strokes/min, macro fibres tend to orient parallel to flow; this can reduce isotropy in the as-placed element if the discharge point is not rotated. The micro fraction is easily transported through the pump mechanism, but the macro fraction may separate near the hopper grate if the grate spacing is less than 40 mm. To maintain uniform fibre content, the hopper should be kept at least 50% full, and the concrete should not be re-tempered with water after pumping. Pump-line pressure increases proportionally with fibre dosage; field observations indicate that at 3.0 kg/m³, line pressure may increase by 5–10% relative to plain concrete of the same slump. The use of a pump line elbow with a radius smaller than 0.5 m may produce local fibre segregation at the outer wall.

    In precast tunnel segment production using steel moulds, vibration frequency between 50–100 Hz can cause fibre settlement if vibration is applied for more than 60 s per point. Macro fibres do not have the same density mismatch as steel fibres, so settlement is less severe, but the micro fraction can float in high-slump mixes. Compatibility with common admixture classes is generally acceptable, but the fibre–paste bond is sensitive to excessive air-entraining admixture because the micro-fibril surface area competes for surfactants. Air content should be maintained within the specified range under ASTM C231/C231M, with adjustments made after fibre addition. Aromatic hydrocarbon exposure should be avoided because polypropylene softens in contact with certain solvent-based form-release agents and curing compounds.

    The product is not a replacement for primary steel reinforcement in tension zones. Design with fibre-reinforced concrete must follow project standards, such as ACI 544.4R or fib Model Code 2010. At dosages above 4.0 kg/m³, batching and placement difficulties may outweigh residual strength gains; published data for this specific configuration is limited. The material is not intended for applications where sustained temperatures exceed the softening range of polypropylene or where oxidising acids are continuously present.