| HS Code | 458036 |
| Fiber Type | Synthetic hybrid |
| Material Composition | Polypropylene and polyethylene blend |
| Specific Gravity | 0.91 |
| Fiber Length | 1.5 in (38 mm) |
| Fiber Diameter | 0.02 in (0.5 mm) |
| Aspect Ratio | 75 |
| Tensile Strength | 80,000 psi (550 MPa) |
| Modulus Of Elasticity | 1,000,000 psi (6,900 MPa) |
| Melting Point | 320°F (160°C) |
| Ignition Point | 590°F (310°C) |
| Water Absorption | Nil |
| Alkali Resistance | Excellent |
| Chemical Resistance | Excellent |
| Electrical Conductivity | Low |
| Corrosion | Non-corrosive |
| Dosage | 1.5 to 6.0 lb/yd³ (0.9 to 3.6 kg/m³) |
| Packaging | 5 lb (2.27 kg) bags |
| Compliance | ASTM C1116/C1116M Type III, ASTM D7508 |
| Shelf Life | 2 years |
| Storage | Store in dry conditions |
As an accredited MasterFiber MAC 360 FF - Synthetic Hybrid Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | MasterFiber MAC 360 FF – Synthetic Hybrid Fiber is packaged in 20 kg moisture-resistant bags, palletized and shrink-wrapped. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized MasterFiber MAC 360 FF synthetic hybrid fiber, shrink-wrapped, strapped, and secured for ocean freight. |
| Shipping | MasterFiber MAC 360 FF is typically supplied in 1 lb water-soluble bags, 50 bags per carton, 40 cartons per pallet. Ship and store dry at ambient temperature, away from moisture. It is non-hazardous, with no special DOT/IMDG/ADR classification. Handle with normal PPE; avoid dust and bag damage. |
| Storage | Store in a cool, dry, well-ventilated area in tightly sealed original packaging. Protect from moisture, direct sunlight, and temperature extremes. Keep pallets off the ground; avoid damaging bags and excessive stacking. Prevent dust accumulation and ignition sources. Follow local regulations and the safety data sheet. Store away from incompatible materials and observe recommended shelf life. Rotate stock. Ensure good housekeeping. |
| Shelf Life | The shelf life is 24 months from date of manufacture when stored in original, unopened packaging under dry, moderate conditions. |
The design condition that triggers substitution of conventional welded wire reinforcement with MasterFiber MAC 360 FF in ground-bearing industrial slabs is not the average flexural stress at the slab center, but the localized demand at free-movement saw-cut joints and the crack-width controlled post-cracking capacity beneath high-bay racking upright point loads. Under Concrete Society TR34, 4th Edition (2016) design methodology for fibre-reinforced ground slabs, the residual flexural strength ratio derived from EN 14651:2005+A1:2007 testing is used directly to calculate moment transfer across joints where dowel bars are omitted for schedule and durability reasons. The fibre addition range for this application class is 3.0–5.0 kg/m³, with the upper bound reserved for slabs carrying racking point loads exceeding 200 kN per upright and joint spacing extended beyond 6.0 m. Product conformity verification is governed by EN 14889-2:2006, which requires declared values for fibre geometry, tensile strength, and alkali resistance as conditions for CE marking under the Construction Products Regulation.
Batching sequence is the primary production variable that distinguishes successful fibre dispersion from premature fibre balling in ready-mix operations. The fibre is introduced into the mixer after the coarse aggregate and cementitious fraction have been partially homogenised, typically at 70–80% of total mixing time, and the drum or twin-shaft mixer is then held at full speed for an additional 3–5 minutes beyond the standard mixing cycle. Automated fibre dosing systems capable of sustained feed rates between 15–25 kg/min prevent the intermittent dumping events that produce clumped fibre masses in high-shear pan mixers and truck mixers alike. Slump absorption at the 4.0 kg/m³ dosage point is typically 20–40 mm in a 0.45 w/c reference mixture, which must be compensated through polycarboxylate ether superplasticiser dosage increases of approximately 0.15–0.30 L/m³ rather than through water addition, since adding water dilutes the paste fraction and compromises the bond between the hybrid fibre surface and the hydrated cement matrix. Placement is executed with laser screed equipment receiving concrete at pump rates of 30–60 m³/h, and the finishing sequence is critically dependent on the evaporation rate: pan float blades must not engage before bleed water has cleared, because premature troweling under fibre-reinforced concrete conditions drags surface fibres into the plane of the slab and produces visible fibre protrusion that cannot be corrected after the floor has hardened.
Compliance testing for this application is anchored to ASTM C1609/C1609M-19a beam tests and the European notched beam method under EN 14651. The relevant residual strength parameters include fR1k at a crack mouth opening displacement of 0.5 mm, which characterises the capacity across early service cracks, and fR3k at 2.5 mm CMOD, which is used for ultimate limit state calculations where aggregate interlock has degraded. For macro synthetic hybrid fibre systems dosed within the prescribed window, the fR1k/fLOP ratio typically falls between 0.45–0.65, indicating a controlled post-crack response without the brittle snap-through behaviour observed in unreinforced concrete. The following matrix consolidates the normative references governing material conformity, testing procedures, and design application in warehouse and logistics slab installations.
| Standard Designation | Title / Test Method | Parameter or Conformity Function |
|---|---|---|
| EN 14889-2:2006 | Fibres for concrete – Part 2: Polymer fibres – Definitions, specifications and conformity | CE marking basis; declared tensile strength, alkali resistance, geometry |
| EN 14651:2005+A1:2007 | Test method for metallic fibre concrete – flexural tensile strength (LOP, residual) | fR1k at 0.5 mm CMOD; fR3k at 2.5 mm CMOD |
| ASTM C1609/C1609M-19a | Flexural performance of fiber-reinforced concrete (beam with third-point loading) | Residual strength f600, f150; equivalent flexural strength ratio Re3 |
| Concrete Society TR34, 4th Ed. | Guide to design of concrete industrial ground floors | Fibre-reinforced slab design; joint spacing criteria; point load transfer |
| EN 206:2013+A2:2021 | Concrete – specification, performance, production and conformity | Base concrete conformity; exposure class selection; w/c ratio limits |
| ASTM C94/C94M-21 | Standard Specification for Ready-Mixed Concrete | Batching tolerances; fibre addition documentation; delivery time limits |
The terminal product range within this scenario is defined by operational floor environments where mechanical handling equipment imposes localised stress concentrations that sheet reinforcement absorbs poorly due to placement depth variability. These include ambient and cold-store warehouse floors, cross-dock logistics facilities, automotive assembly plant floors where AGV routes create repetitive wheel-path loading, and manufacturing mezzanine slabs where fire insulation requirements favour synthetic fibre over steel fibre for retention of concrete cover. The operational boundary conditions are explicit: the fibre dosage is not a substitute for structural design of piled slabs where ground bearing capacity is deficient, and the product should not be specified interchangeably with steel fibre at identical dosage without revalidation of the fR3k value, because the elastic modulus of synthetic hybrid fibre is lower than that of steel and the post-crack stiffness response curve differs materially at crack widths above 3.5 mm.
Precast concrete segments for shield-driven tunnels and shaft linings represent the most structurally demanding application class for MasterFiber MAC 360 FF because the fibre reinforcement must perform under triaxial compression from tunnel boring machine thrust jacks while simultaneously providing post-crack flexural capacity during demolding, stacking, and ring erection. The dosage window for this scenario is 4.0–8.0 kg/m³, with project-specific optimisation derived from EN 14651 residual strength requirements and the structural design framework published in ITAtech Report No. 7 (2016) on design guidance for precast fibre reinforced concrete segments. Design verification is further supported by ACI 533.5R-16, which documents the material testing regimes and acceptance criteria for fibre-reinforced precast segment liners in North American tunnelling practice, and by ASTM C1399/C1399M-10(2015) or ASTM C1550-20 for average residual strength determination where project specifications deviate from European beam testing conventions.
The production process operates within high-throughput carousel mould systems where cycle time pressures conflict directly with the extended mixing cycles required for adequate fibre dispersion in low workability concrete. Batching is performed in high-shear pan mixers or twin-shaft mixers with batch capacities between 0.75–2.5 m³, and the fibre is introduced after the superplasticiser and silica fume slurry have achieved initial coating of the cementitious fraction. Mixing is extended by 60–120 seconds beyond the standard low-slump cycle, producing a concrete with slump between 40–80 mm that remains compatible with external vibrator compaction on stationary or tilting mould tables. Vibration frequency is typically maintained at 50–100 Hz with amplitude controlled between 0.3–0.8 mm, because excessive amplitude produces fibre segregation toward the mould face and undermines the uniformity of residual strength across the segment thickness. Steam curing is conducted with temperature ramp rates not exceeding 15°C/h to a peak of 55–65°C, and demolding strength is specified at 18–25 MPa compressive strength to prevent corner spalling when hydraulic ejectors release the segment from the mould. Batch-to-batch variance in residual flexural strength has been observed to correlate with fibre dosage deviation of less than ±0.4 kg/m³, which dictates the need for automated weight-verification on the fibre dosing station rather than manual bag addition.
The mechanical qualification of fibre-reinforced segments centres on the relationship between fR1k and fR3k values from EN 14651 notched beam tests, where the ratio fR3k/fR1k is interpreted as a measure of fibre pull-out versus fibre rupture behaviour. In segments dosed at 6.0 kg/m³, the residual strength at 0.5 mm CMOD commonly falls between 2.0–3.0 MPa, while the strength at 2.5 mm CMOD falls between 1.3–2.2 MPa. The table below summarises the typical characterisation envelope reported across independent laboratory studies for macro synthetic hybrid fibre systems in low-w/c cementitious matrices, with the explicit caveat that project-specific certification testing under the governing design code remains mandatory because mix design, curing regime, and aggregate angularity all shift the residual strength values.
| Dosage | fR1k at 0.5 mm CMOD | fR3k at 2.5 mm CMOD | ASTM C1609 f600 | Design Application Class |
|---|---|---|---|---|
| 3.0 kg/m³ | 0.8–1.5 MPa | 0.3–0.8 MPa | 0.7–1.2 MPa | Non-structural crack control; temporary works |
| 4.0 kg/m³ | 1.2–2.0 MPa | 0.6–1.2 MPa | 1.0–1.7 MPa | Industrial floors; composite deck toppings |
| 5.0 kg/m³ | 1.5–2.5 MPa | 1.0–1.8 MPa | 1.3–2.2 MPa | Pavements; shotcrete linings |
| 6.0 kg/m³ | 2.0–3.0 MPa | 1.3–2.2 MPa | 1.7–2.8 MPa | Precast segments; pipes and culverts |
| 7.0 kg/m³ | 2.5–3.5 MPa | 1.7–2.8 MPa | 2.1–3.3 MPa | Tunnel segment liners; shaft linings |
| 8.0 kg/m³ | 3.0–4.0 MPa | 2.0–3.3 MPa | 2.5–3.8 MPa | High-load structural FRC members |
The terminal product range includes single-pass TBM lining segments produced in 1,800–2,200 mm width and 250–400 mm thickness configurations, shaft lining segments for launch and reception shafts, and precast jacking pipes used in microtunnelling where pipe jacking forces impose longitudinal compressive stresses that the fibre reinforcement must accommodate without spalling at the joint faces. Operational boundaries are specific: published data for the precise interaction of this synthetic hybrid fibre with segment reinforcement cages under simultaneous thrust jack loading and grout pressure during annular backfill remains limited, and projects that combine fibre with conventional reinforcement should commission compatibility testing for the reduced-cage configuration during the design phase. The fibre should not be relied upon to replace all conventional segment reinforcement where the design utilises full ring bearing under eccentric jacking load conditions without first validating the fR3k value at the specified concrete age at demolding, which may be 12–16 hours under accelerated curing regimes.
Wet-mix shotcrete applications in underground excavation and rock slope stabilisation introduce a distinctly different fibre performance requirement from static precast concrete: the fibre must survive the high-shear pumping environment, the air entrainment at the nozzle, and the impact energy at the substrate surface while retaining its geometric integrity and post-crack bridging capability in the in-place lining. MasterFiber MAC 360 FF is dosed in the range of 4.0–9.0 kg/m³ in wet-mix shotcrete, with the upper bound reserved for permanent tunnel linings designed as load-bearing structural elements under EFNARC (2002) European Specification for Sprayed Concrete and EN 14487-1:2005 conformity requirements for sprayed concrete materials and execution. Flexural performance is verified through EN 14488-3:2006, which governs the beam testing of fibre-reinforced sprayed concrete and reports first-peak, residual, and ultimate flexural strengths for sprayed specimens that may differ from cast beam results due to anisotropic fibre orientation induced by the spraying process itself.
The production sequence begins with batching in transit mixers or dedicated wet-mix shotcrete plants, where the fibre is added after the cementitious material, aggregate, and water have been mixed to a homogeneous state, followed by additional mixing of 3–5 minutes at full agitation speed. The resulting mixture is pumped through piston or screw-type shotcrete pumps at outputs ranging from 10–25 m³/h, with the nozzle operator applying air at 250–400 L/s and a pressure of 4–7 bar to project the material onto the substrate. For robotic spraying in tunnel linings, the manipulator follows a pre-programmed path maintaining a nozzle distance of 1.0–1.5 m and a spray angle of 85–95° to the receiving surface, which maximises compaction energy while limiting rebound losses that would otherwise remove a disproportionate fraction of the higher-aspect-ratio fibre component. Rebound values for macro synthetic fibre shotcrete typically fall between 10–20%, and the rebound fraction is enriched in fibre relative to the in-place lining, which must be accounted for when verifying the effective in-situ dosage through batching records and rebound sampling. Terminal product types include permanent tunnel support linings in hard rock and soft ground, temporary rock slope stabilisation, underground mine access headings, and sprayed concrete shafts and adits where conventional mesh installation is too hazardous or too slow for the excavation cycle. The principal operational limitation is the interaction between the fibre and the accelerator admixture: alkali-free set accelerators are preferred because alkali-rich formulations can reduce the bond between the polymer fibre surface and the surrounding cement paste, and the accelerator dosage must be recalibrated when fibre dosage changes by more than ±0.5 kg/m³ to maintain the required early-age strength gain for overhead spraying without excessive sloughing.
Composite steel deck floor systems in multi-storey steel-frame buildings utilise concrete toppings that act integrally with the profiled deck through shear studs, and the addition of synthetic hybrid fibre is specified primarily to control plastic shrinkage cracking and to provide distributed crack width limitation in the negative moment regions over deck ribs where conventional welded wire reinforcement is difficult to place at the correct cover depth. The dosage of MasterFiber MAC 360 FF in this application is comparatively low at 2.0–4.0 kg/m³, because the structural capacity of the composite slab is derived principally from the composite action between the concrete topping and the steel deck as governed by ANSI/SDI C-2017 composite steel floor deck-slab design provisions and the applicable acceptance criteria set out in IBC Section 1905 for fibre-reinforced concrete tested under ASTM C1609/C1609M-19a. The product conformity requirement is discharged under EN 14889-2:2006 for CE-marked material supplied to European-influenced project specifications, while North American projects reference the Underwriters Laboratories fire resistance directory and ASTM E119 fire exposure test results for the particular deck-topping assembly.
Placement is executed by pumping through 50–75 mm diameter rubber-lined hoses at rates of 20–40 m³/h, with the concrete discharged directly onto the profiled deck and struck off with vibrating truss screeds or hand-operated straightedges. The topping thickness typically ranges from 65–130 mm above the top of the deck ribs, and the fibre dosage must be verified against a maximum aggregate size of 10–14 mm, which is dictated by the cover requirements over the profiled ribs and by the need to prevent fibre entanglement with transverse reinforcement where present. Terminal product types include office tower composite floor slabs, hotel and residential deck toppings, podium slab decks over parking structures, and roof deck composite systems. The operational boundary is set by the interaction of the synthetic fibre with the trowelling operation: because the topping is generally specified with a hard-trowel finish for direct vinyl or carpet application, the finishing crew must delay power trowel engagement until the bleed water has fully evaporated, since early troweling of fibre-bearing concrete produces the same surface fibre protrusion defects described in slab-on-grade work and compounds them in thin sections where there is no depth to rebury protruding fibres.
Dry-cast production of precast drainage structures involving immediate demolding and rapid mould turnover cycles creates a fundamentally different fibre dispersion environment from wet-cast slipform operations, because the zero-slump concrete is compacted by high-frequency external vibration rather than by internal consolidation. MasterFiber MAC 360 FF is introduced into dry-cast and semi-dry-cast mixtures at 3.0–6.0 kg/m³ for concrete pipes, box culverts, and manhole components manufactured under EN 1916:2002, which covers concrete pipes and fittings including steel fibre reinforced and synthetic fibre reinforced variants when conformity is demonstrated through type testing and factory production control. In North American practice, the applicable performance references include ASTM C1765-19, which establishes the test requirements for fibre-reinforced concrete culvert and drainage pipe, and AASHTO M 170 for reinforced concrete culvert structures, with the provision that synthetic fibre qualification must be conducted on the actual production mix because residual strength in dry-cast products is more sensitive to compaction energy than in equivalent wet-cast concrete.
The production line configuration for dry-cast pipe and culvert manufacturing involves the addition of the fibre directly into the pan mixer or planetary counter-current mixer during the dry blending phase, prior to the addition of the low water content that brings the mixture to the zero-slump state. Mixing cycle extension of 45–90 seconds beyond the standard cycle is typically required, and the compaction is performed on automated vibration stations operating at frequencies between 45–65 Hz with the mould filled in controlled lifts to ensure uniform fibre distribution through the entire wall thickness. The low water content of dry-cast concrete, typically 0.25–0.35 w/c, means that the fibre must be compatible with the extended mixing time without generating electrostatic clumping, and fibre bundling at the feed point has been identified as the dominant production failure mode when ambient humidity exceeds 60% and the fibre material has not been stored in sealed packaging prior to use. Terminal product types include stormwater drainage pipes in diameters from 300 mm to 1,800 mm, box culverts for stream crossings and utility corridors, catch basin risers, and manhole base sections. The structural function of the fibre in these products is predominantly crack width control and impact resistance rather than full replacement of the steel cage reinforcement specified for high-earth-load conditions, and the fibre dosage alone does not substitute for the tensile steel required when the installation depth exceeds the design cover limits under AASHTO live load configurations.
Heavy-duty pavement applications at container terminals, intermodal rail yards, and airfield aprons subject the fibre-reinforced concrete to concentrated wheel loads from reach stackers, rubber-tyred gantry cranes, and aircraft landing gear, where the primary design objective is crack width control and fatigue resistance under high-cycle point loading. The addition of MasterFiber MAC 360 FF in slipform-paved hardstand slabs is specified at 3.0–5.0 kg/m³, with pavement thicknesses from 250 mm to 400 mm determined by the governing pavement design methodology. For airfield applications, the design basis is FAA AC 150/5320-6G airport pavement design and evaluation procedures, while industrial hardstands and container yards follow ACI 330.1-14 for unreinforced concrete parking lots and site paving with fibre reinforcement, and flexural performance verification is performed under ASTM C1609/C1609M-19a. The batching and mixing operations are conducted in central mix plants feeding slipform pavers or transit mixers serving fixed-form placement, with the fibre introduced at the plant and the mixture transported under agitation to the paving front.
The production process uses slipform paver equipment advancing at 0.8–1.5 m/min with an automatic dowel bar inserter where joints are specified, or laser-guided screeds for fixed-form bays where the fibre-reinforced concrete provides the crack width control that permits joint spacing extension beyond the unreinforced limit. Saw-cut contraction joints are executed at intervals between 6.0–9.0 m, and the saw-cutting window is delayed relative to unreinforced concrete because the fibre bridging resists early crack formation, requiring the contractor to monitor slab surface temperature and moisture loss rather than relying on a fixed cutting schedule. Terminal product types include container yard storage slabs, intermodal rail transfer aprons, airport taxiway and apron overlays, and heavy industrial hardstands supporting rubber-tyred gantry crane wheel loads approaching 45 kN per wheel. The limitation is specific to the reinforcement function: the synthetic hybrid fibre does not add to the compressive or flexural stiffness of the slab in the uncracked state, and therefore it cannot reduce the required pavement thickness below the value determined by soil subgrade modulus and the governing bending stress calculation, nor does it replace the dowel bars at construction joints where vertical shear transfer is required by design.
Competitive MasterFiber MAC 360 FF - Synthetic Hybrid Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
MasterFiber MAC 360 FF is classified as a synthetic hybrid macrofiber for concrete reinforcement, specified by the manufacturer for slab-on-grade, precast concrete, shotcrete, and composite metal deck applications. The product is differentiated from microsynthetic monofilament fibers by its longer macrofiber geometry and from steel fiber by its lower density and non-corroding polymer matrix. Published technical data list a nominal length of 60 mm, a specific gravity of 0.91 g/cm³, a tensile strength of approximately 620 MPa, and a modulus of elasticity of 9.5 GPa. The melting point is reported as 162 °C. Recommended addition rates range from 3.0 kg/m³ to 9.0 kg/m³, corresponding to approximately 0.33% to 0.99% by volume at the published density. The material is addressed under ASTM C1116/C1116M Type III synthetic fiber classification and EN 14889-2 as a polymer fiber for structural use in concrete. The product does not replace continuous steel reinforcement in primary tension zones unless explicitly accepted by the structural design.
| Property | Published value | Test method or basis |
|---|---|---|
| Specific gravity | 0.91 g/cm³ | ASTM D792 |
| Tensile strength | 620 MPa | ASTM D3822 |
| Elastic modulus | 9.5 GPa | ASTM D3822 |
| Melting point | 162 °C | ISO 11357 |
| Nominal length | 60 mm | Manufacturer geometric data |
| Water absorption | <0.1% by mass | ASTM D570 |
| Dosage range | 3.0–9.0 kg/m³ | Manufacturer recommendation |
The fiber is batch-blended as a discrete phase. Plant-scale experience indicates that fiber introduction after aggregate charging and before final water metering in a twin-shaft mixer with a wet mixing period of 4 to 5 minutes produces uniform distribution. Premature addition to dry aggregate in a counter-current pan mixer may create fiber balling at dosages above 6 kg/m³. Because the polymer is hydrophobic and has a specific gravity of 0.91 g/cm³, it does not absorb batch water, and the effective water–cement ratio is not directly altered by fiber water demand. Slump under ASTM C143/C143M is commonly reported to decrease by 10 mm to 30 mm at a dosage of 5 kg/m³. This reduction is managed with plastifying admixtures rather than by increasing batch water. Pumpability through 125 mm to 150 mm concrete pump lines is maintained when the aggregate grading contains sufficient fines. The fiber does not segregate under normal truck drum agitation at 6 rpm to 10 rpm. Published data for specific truck drum mixing energy and paddle geometry is limited, but standard ready-mix practice is accepted within the manufacturer’s dosage range.
Post-crack flexural performance is quantified under ASTM C1609/C1609M using 150 mm × 150 mm × 500 mm beams loaded at third points. The measured parameters include residual load at net deflections of L/600 and L/150. At a dosage of 3.0 kg/m³, the product principally influences plastic shrinkage cracking resistance. At 5.0 kg/m³ and above, the macrofiber contributes measurable post-crack load resistance in slab elements. European evaluation under EN 14651 uses a 150 mm × 150 mm × 550 mm notched beam, with residual flexural tensile strength reported at crack mouth opening displacement values of 0.5 mm and 2.5 mm. The resulting residual strength is not a direct substitute for structural steel reinforcement. Design methods such as ACI 544.4R and the fib Model Code 2010 require slab moment capacity verification using stress–crack width relationships. Independent laboratory data for this specific product configuration are limited; project-specific trial batches are therefore required before design release.
In wet-mix shotcrete, the product is introduced at the batching plant before pumping. The macrofiber orientation in the sprayed layer can reduce rebound relative to plain shotcrete, but published quantified rebound reduction for this specific product and nozzle configuration is limited. Spraying through 50 mm to 65 mm hose diameters does not impose additional restriction beyond normal aggregate grading controls. High dosages above 7 kg/m³ may reduce pump output on long horizontal runs. The material is not a substitute for welded wire mesh in structural shotcrete linings unless the design is verified under EN 14487 or project-specific performance tests. Trial spraying is required to establish pump pressure, rebound, and early-age bonding on the actual substrate.
Replacement of welded wire mesh is a design decision, not an inherent product property. At a dosage of 5.0 kg/m³, the fiber volume fraction is approximately 0.55%. At this fiber content, post-crack residual capacity can satisfy serviceability criteria for distributed shrinkage restraint and edge loading when joint spacing is maintained. By comparison, a typical steel fiber slab dosage of 25 kg/m³ corresponds to a volume fraction of 0.32% at a steel density of 7.85 g/cm³. Equal mass dosages of steel and synthetic macrofiber do not yield equal fiber count or equal crack-bridging behavior. The synthetic macrofiber supplies a higher number of discrete elements per kilogram, but each element has lower axial stiffness than steel. Macro-synthetic reinforcement is not accepted as primary flexural reinforcement in tension zones without test verification. Concentrated point loads, racking systems, seismic tie-downs, or heavy wheel traffic require explicit structural calculation. The fiber may reduce crack widths after formation but does not eliminate drying shrinkage deformation. Joint spacing, concrete cover, and curing regimes remain primary controls for slab movement.
| Parameter | Steel macrofiber | MasterFiber MAC 360 FF |
|---|---|---|
| Material density | 7.85 g/cm³ | 0.91 g/cm³ |
| Typical slab dosage by mass | 25 kg/m³ | 5 kg/m³ |
| Volume fraction at typical slab dosage | 0.32% | 0.55% |
| Electrochemical corrosion in cracked concrete | Possible without adequate cover and chloride threshold control | None reported |
The fiber is moisture-insensitive and does not require pre-drying at relative humidity below 80%. Storage in sealed bags at 5 °C to 35 °C is standard. The product is not biodegradable under normal concrete service conditions. Compliance under EN 14889-2 requires the manufacturer to declare tensile strength and modulus; the product is CE marked for structural use in concrete as a polymer fiber. In North America, ASTM C1116/C1116M Type III synthetic fiber classification applies. The material is not intended as primary reinforcement. In service environments with sustained temperatures above 100 °C, modulus loss becomes significant as the polymer matrix approaches its melt transition. The product should not be used in fire-resistance-critical structural elements without specific testing. The polymer is resistant to cement alkalinity at pH 13 and above, but no long-term alkali-resistance standard is cited in the manufacturer’s routine product literature. No adverse reaction with air-entraining admixtures, high-range water reducers, silica fume, or slag cement has been published, but site-specific compatibility trials are recommended.
For precast elements demolded within 12 to 24 hours, the macrofiber can reduce handling breakage and corner spalling. In tunnel segment linings, the product may be evaluated for crack control under early-age requirements, but it does not replace steel dowels or segment bolts. Published data for this specific product in one-pass TBM segment linings is limited; production trial panels and standard flexural tests are required. Dosage in precast applications typically falls between 4 kg/m³ and 6 kg/m³. Fiber addition in a precast counter-current mixer with a dry pre-mix time of 30 seconds and a wet mixing time of 90 seconds is sufficient for uniform distribution when the dose is verified by washout sampling.