| HS Code | 676966 |
| Productname | SikaFiber Novomesh 950 |
| Alternatenames | Novomesh 950; SikaFiber Force 950 |
| Producttype | Blend of macro and micro synthetic fibers |
| Fibermaterial | Polypropylene |
| Fiberlength | Macro: 40 mm; Micro: 12 mm |
| Fiberdiameter | Macro: 0.8 mm; Micro: 0.032 mm |
| Tensilestrength | 400 MPa |
| Elasticmodulus | 5 GPa |
| Meltingpoint | 160 °C |
| Ignitionpoint | 590 °C |
| Waterabsorption | <0.1% |
| Alkaliresistance | Excellent |
| Acidresistance | Excellent |
| Uvresistance | Excellent |
| Electricalconductivity | Low |
| Chloridecontent | Nil |
| Dosage | 3.0 kg/m³ (5 lb/yd³) |
| Packaging | 2.5 kg (5.5 lb) bags |
| Shelflife | 24 months |
| Storageconditions | Dry, protected from UV, 5-30 °C |
| Color | Gray |
| Form | Solid discrete fibers |
| Odor | Odorless |
| Toxicity | Non-toxic |
| Compliance | ASTM C1116 Type III; EN 14889-2 |
As an accredited SikaFiber Novomesh 950 (Novomesh 950 / SikaFiber Force 950) - Blend of Macro and Micro Synthetic Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber Novomesh 950 is packaged in 1 lb (0.45 kg) water-soluble bags, supplied 40 bags per carton, 40 lb total. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): SikaFiber Novomesh 950 macro/micro synthetic fiber blend, palletized and shrink-wrapped, securely loaded for export. |
| Shipping | SikaFiber Novomesh 950 / SikaFiber Force 950 is a non-hazardous synthetic macro/micro fiber blend. It is not classified as dangerous goods for transport. Ship in original sealed bags or boxes, palletized, kept dry and protected from moisture, contamination, and damage. No special transport labels required; follow local regulations. |
| Storage | Store SikaFiber Novomesh 950 in its original, unopened packaging in a dry, cool, well-ventilated, covered area. Keep away from moisture, direct sunlight, heat, flames, and incompatible materials. Maintain containers tightly closed, protect from physical damage, and avoid dust generation. Recommended storage temperature is 5–30°C; shelf life is typically 24 months when stored properly. Use first-in, first-out stock rotation. |
| Shelf Life | Shelf life is 24 months from date of manufacture when stored dry in original unopened packaging, protected from moisture and sunlight. |
At a precast plant producing tunnel segments, SikaFiber Novomesh 950 (also designated SikaFiber Force 950 in certain market jurisdictions) is charged through a bag-breaking feeder interlocked with the aggregate weigh belt so that the fibre stream enters the mixer during the latter half of coarse aggregate loading. The blended macro/micro package is supplied as a disintegrating bag that is degraded by mixing action; the micro fraction disperses into the mortar phase while the macro fraction remains within the coarse aggregate skeleton. Dosage is maintained at 4–6 kg/m³ because this range corresponds to post-crack residual strength requirements under EN 14651:2012 and ASTM C1609/C1609M-19, while doses below 3 kg/m³ do not reliably bridge cracks wider than 0.2 mm in segment flexural tests. The concrete matrix is a C50/60 mix with w/c ratio 0.36, total air content 1.5–2.5%, and a target discharge slump of 120 ± 20 mm. When the fibre dosage increases to 6 kg/m³, placement crews observe a slump reduction of 20–40 mm despite increased polycarboxylate ether dosage of 0.2–0.4% by weight of cement, especially if the mix is held in transit for more than 45 min. Segments are cast in automated carousel moulds fitted with 50 Hz external vibrators; concrete containing the fibre blend requires an additional 5–10 s of vibration per mould side to release air trapped behind macro fibres at the form face. Stripping at 8–10 h with accelerated steam curing at 55–60 °C is not adversely affected, but edge spalling can occur if the macro fibre density at the mould edge exceeds 8 kg/m³ due to operator over-dosing. Compliance is documented under EN 14889-2:2006 with CE marking under Regulation (EU) No 305/2011, and production records include batch fibre mass verification against the ±0.5 kg tolerance of the automated feeder.
The selection of the fibre dosage in ground-supported slabs is governed by residual strength rather than compressive strength. For slabs exposed to hard-wheeled forklift traffic and high-bay racking, SikaFiber Novomesh 950 is batched at 3–5 kg/m³ when the macro fraction replaces welded wire mesh and the micro fraction targets plastic shrinkage cracking. Post-crack performance is evaluated with EN 14651:2012 using notched beams loaded at a constant CMOD rate of 0.05 mm/min until 0.5 mm; project specifications typically require fR,1 ≥ 1.5 MPa and fR,3 ≥ 1.0 MPa at 2.5 mm CMOD for slabs designed to replace A142 mesh. In North American practice, ASTM C1609/C1609M-19 is applied and the fibre blend is evaluated for f600 and f150 residual flexural strengths. Plastic shrinkage cracking is screened under ASTM C1579-21; a dosage of 3 kg/m³ of the micro component is accepted when the crack width is limited to 0.2 mm at 24 h. The fresh concrete is pumped through a 125 mm nominal steel pipeline with an S-valve piston pump; delivery pressure is kept below 85 bar because pressure spikes occur at fibre accumulations in reducers. At a dosage of 4 kg/m³, the slump can drop by 25–50 mm from a 150 mm reference, and the plant must add 0.2–0.5% polycarboxylate ether by cement weight when the aggregate moisture drops below 2%. If the fine aggregate-to-total aggregate ratio is below 0.42, macro fibres may form balls under high-speed mixing; the ratio should be held at 0.45–0.50 for continuously mixed slabs. Laser screed placement proceeds in strips of 3–4 m width, and early-age saw cuts are executed when the concrete reaches a compressive strength of 3.5–5.0 MPa or before 18 h in warm weather. The terminal slab is not freed from joint design; diamond dowel baskets at 300 mm centres are retained at free construction joints for load transfer.
Wet-mix sprayed concrete for primary rock support introduces different placement constraints. The dual fibre package is added at the batch plant before the air-entraining admixture, because delayed addition can cause the micro fibre fraction to float onto the mixer surface and enter the pump hopper as a segregated mass. Typical fibre dosage is 4–7 kg/m³ in a base mix with 8 mm maximum aggregate, cement content 400–450 kg/m³, silica fume 20–30 kg/m³, w/c ratio 0.40–0.45, and superplasticizer adjusted to maintain a pumpable slump of 140–180 mm at the hopper. The wet-mix machine is a piston pump with S-valve and 100–125 mm delivery line; concrete output is matched to 10–15 m³/h and nozzle air is set at 5–8 m³/min at 6–7 bar. Set accelerator is injected at the nozzle at 3–6% by weight of cement, depending on ground water inflow and overhead thickness. The macro fibre fraction resists tensile stress after the lining has undergone displacement, while the micro fibre fraction suppresses plastic shrinkage cracking near the accelerator-enriched surface. Rebound increases when the nozzle distance exceeds 1.5 m or when the nozzle angle falls below 70° to the receiving surface; fibre rebound is visually detectable as protruding macro fibres in the rebound pile. Blockage risk rises at macro fibre dosage above 7 kg/m³ in a 100 mm line, especially if the pump stroke volume is below 0.5 L per stroke; a 125 mm line and full-flow couplings are specified for continuous underground operation. The placed shotcrete is tested under EN 14487-1:2005 for conformity and under EN 14488-3 for flexural toughness; sprayed panels are produced on site and cut into beams. Published data for this exact hybrid geometry in permanent NATM linings is limited, so production trials should compare the selected dosage against a reference steel-fibre shotcrete at the same residual strength class.
Dry-cast concrete pipe and box culvert production operates at zero-slump consistency and immediate demoulding, which changes the fiber distribution behaviour. SikaFiber Novomesh 950 is batched into a countercurrent mixer after the aggregate but before the cement, at 3–5 kg/m³, and the wet mixing time is extended to 90–120 s because the macro fraction must be coated with dry fines to prevent fibre-on-fibre friction in the packerhead compaction zone. In dry-cast pipe, the w/c ratio is 0.26–0.34 and the cement content is 350–400 kg/m³; the macro fibres are too stiff to be compacted into the densely packed ring without losing green strength if the dosage exceeds 5 kg/m³. Vertical vibration is applied at 50–60 Hz with a packerhead or rollerhead machine, and the compaction time is extended by 5–10 s per pipe relative to the unreinforced control. The terminal products are storm drains, culverts, and manhole risers produced under ASTM C76 and EN 1916:2002. Crack width control is measured under ASTM C497 three-edge bearing; the fibre-reinforced sections are specified for 0.25 mm crack width criteria in mildly aggressive soils. The micro fibre fraction reduces surface edge chipping during demoulding and handling, but does not replace the steel cage in high-load classes where D-load exceeds 75 kN/m. When ambient temperature falls below 10 °C, the dry-cast producer must extend the pre-cure interval before steam introduction because the synthetic fibre surface can act as a nucleation point for water condensation on the exposed pipe crown. If fibre dosage exceeds 5 kg/m³, green springback after compaction can reduce the pipe wall thickness by 1–2 mm; production trials should verify the mandrel diameter and yoke pressure against the densified fibre-bearing mix.
| Application segment | Dosage range | Fresh concrete control | Hardened-state standard | Production equipment |
|---|---|---|---|---|
| Precast tunnel segments | 4–6 kg/m³ | Slump 120 ± 20 mm, air 1.5–2.5% | EN 14651:2012, ASTM C1609/C1609M-19 | Twin-shaft countercurrent mixer, carousel mould, 50 Hz vibrators |
| Ground-supported industrial slabs | 3–5 kg/m³ | Slump drop 25–50 mm at 4 kg/m³ | EN 14651:2012, ASTM C1579-21 | S-valve pump, 125 mm line, laser screed |
| Wet-mix shotcrete | 4–7 kg/m³ | Hopper slump 140–180 mm, w/c 0.40–0.45 | EN 14487-1:2005, EN 14488-3 | Piston pump, 100–125 mm line, nozzle air 5–8 m³/min |
| Dry-cast pipe and culvert | 3–5 kg/m³ | Zero-slump, w/c 0.26–0.34 | ASTM C76, EN 1916:2002 | Packerhead/rollerhead, 50–60 Hz compaction |
Container yard pavements are placed by slipform or fixed-form methods in widths of 4.5–6.0 m and thicknesses of 200–250 mm. SikaFiber Novomesh 950 is dosed at 4–6 kg/m³ in C30/37 concrete with a 0.42 w/c ratio and 5.5% air content for freeze-thaw exposure. The fibre is introduced in a continuous mixer at a metering tolerance of ±0.5 kg/m³; the mixing time after fibre addition is 60 s for a 2.0 m³ twin-shaft mixer. In slipform paving, the macro fibre fraction stiffens the fresh mix and can cause edge slump behind the paver pan if the mortar volume is below 28%; therefore, the fine aggregate content is increased by 2–3% relative to the unreinforced control mix. Joint design is not eliminated by the fibre blend. Transverse contraction joints are sawed at intervals of 4.5 m and 1/4 of the slab depth, and load-transfer dowels are installed at 300 mm centres for slabs subject to straddle carrier wheel loads. The hybrid fibre package supports crack-width control at the joint corners, but does not replace structural load transfer. Compressive and flexural strength are tested under EN 12390-3:2019 and EN 12390-5:2019; fibre distribution is verified during a pre-construction trial by washing out 50 kg samples from sequential mixer discharge and counting macro fibres. A recorded variance above ±8% between samples triggers a change in the fibre dosing sequence. For refrigerated container stacking areas, the slab is placed as a single layer to avoid cold joints; the fibre-bearing concrete is insulated and cured under ASTM C171 for 7 d to reduce early-age shrinkage. At ambient temperatures above 30 °C, the saw cut timing is brought forward to 6–8 h because the micro fibre fraction does not prevent thermal contraction cracking once the concrete begins to cool.
Composite floor slabs on profiled steel decking receive the hybrid fibre addition at the ready-mix plant after the first 20% of the mixing water has been added, because the micro component competes with cement for wetting and can form low-density agglomerates at the discharge gate. The dosage is 2–5 kg/m³ for slabs of 50–75 mm depth over trapezoidal or re-entrant deck profiles. Pumping is carried through a 100–125 mm line at a concrete output of 20–30 m³/h; the macro fibre fraction increases the dynamic yield stress of the fresh concrete, so the pump pressure limit is set at 70 bar and the line is cleaned when the concrete remains static for more than 20 min. The terminal composite slab uses the macro fibres to distribute post-cracking tensile stresses in the sagging region between the steel deck ribs, while the micro fibres limit plastic settlement cracks above the deck crests. For fire resistance, the polyolefin micro fraction is evaluated for spalling mitigation under EN 1363-1:2020 because the fibres leave capillary channels after melting at approximately 160 °C; however, the fibre blend cannot replace the welded mesh required by EN 1994-1-1:2004 for fire-exposed composite slabs. Shot-fired fasteners and through-deck studs are installed after the fibre-reinforced concrete has developed 70% of the specified compressive strength; early installation at lower strength can disturb the macro fibre orientation at the deck interface. On high-rise projects with repetitive pours, the fibre is pre-blended into bulk bags and discharged through a screw feeder at 0.5–1.0 kg/s into the mixing truck, which reduces batch-to-batch variation to ±0.3 kg/m³. The surface is finished with a power float after bleeding ceases; the micro fibre fraction can reduce bleed water by 10–20%, so finishers must begin machine trowelling earlier than in plain concrete.
Competitive SikaFiber Novomesh 950 (Novomesh 950 / SikaFiber Force 950) - Blend of Macro and Micro Synthetic Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber Novomesh 950, also designated Novomesh 950 and SikaFiber Force 950, is a blended macro–micro synthetic fibre system for structural concrete, wet-mix sprayed concrete, and ground-supported slabs. The product is positioned within the polymer fibre category addressed by EN 14889-2:2006 and is commonly specified under the synthetic fibre-reinforced concrete classification of ASTM C1116/C1116M Type III. The blend contains an embossed macro-monofilament population for hardened-state post-crack performance and a micro-synthetic population for plastic-state shrinkage and settlement control. Published batch-specific values for exact fibre length, diameter, blend ratio, and dosage-response curves are manufacturer-controlled and should be verified against the current CE certificate and accompanying technical data sheet. The class-level data presented below are therefore screening references drawn from industrial literature for olefinic macro-synthetic and micro-synthetic fibres rather than batch-specific product certificates.
For olefinic macro-synthetic fibres of the class used in Novomesh 950, specific gravity is generally reported between 0.90 and 0.92, tensile strength between 300 MPa and 600 MPa, and elastic modulus between 3 GPa and 10 GPa when evaluated under ISO 527-1 or ASTM D638. Macro fibre length is typically in the 30–60 mm band, with diameter between 0.5 mm and 1.0 mm, yielding an aspect ratio of 50–120. The micro-synthetic fraction is commonly reported at length 12–19 mm and diameter 18–30 µm, with plastic shrinkage control dosages of 0.6–1.8 kg/m³. For structural slabs and sprayed concrete, the macro fraction of a dual-population blend is generally dosed at 3–8 kg/m³ depending on the required energy absorption class, slab thickness, and joint layout. These values are class-level ranges; published data for the exact blend ratio and batch-specific performance of SikaFiber Novomesh 950 are limited, and the manufacturer’s current CE certificate should be treated as normative.
| Property | Test basis | Hooked-end steel fibre | Macro synthetic fibre class | Micro synthetic fibre class |
|---|---|---|---|---|
| Specific gravity | ISO 1183-1 | 7.85 | 0.90–0.92 | 0.90–0.91 |
| Tensile strength | ISO 527-1 / ASTM D638 | 1000–1500 MPa | 300–600 MPa | 250–450 MPa |
| Elastic modulus | ISO 527-1 / ASTM D638 | 200 GPa | 3–10 GPa | 2–5 GPa |
| Typical dosage | Mix design validation | 20–40 kg/m³ | 3–8 kg/m³ | 0.6–1.8 kg/m³ |
| Primary function | — | Post-crack flexural resistance | Post-crack toughness and crack control | Plastic shrinkage and settlement control |
Concrete production with the blend requires attention to batching sequence and mixer condition. In a planetary counter-current or twin-shaft concrete mixer, the fibres are usually introduced after the aggregates, cement, and water have been initially combined, or through an automated fibre dosing station on the aggregate conveyor. The objective is to prevent electrostatic clumping and localised fibre balling at the discharge gate. Manual addition from pre-weighed bags is acceptable when the bag mass corresponds to the batch volume and the addition is spread over the mixer opening rather than discharged as a single mass. Slump management should be measured by EN 12350-2 or ASTM C143/C143M; synthetic fibres typically reduce slump as the fibre volume fraction increases. Water must not be added to restore slump beyond the mix design water-cement ratio, because this changes capillary porosity and compressive strength measured under EN 12390-3.
The micro-synthetic population acts during the plastic state by increasing the fibre count per unit volume. The fibres bridge bleeding channels and arrest microcracking before it coalesces into visible surface cracks. Restrained plastic shrinkage testing under ASTM C1579-21 is the standard method used to compare crack area between a reinforced mix and an unreinforced control. Performance in this test is strongly governed by environmental evaporation rate, concrete temperature, cement fineness, and fibre dosage; therefore no single crack-reduction percentage is universally valid. In the hardened state, the embossed macro-monofilament population engages after the cementitious matrix cracks. Flexural performance is characterised under EN 14651:2005+A1:2007, in which the residual flexural tensile strength values fR1 and fR4 are determined at crack mouth opening displacements of 0.5 mm and 3.5 mm, respectively. The US method ASTM C1609/C1609M determines residual strength at net deflections of L/600 and L/150. The macro fraction does not replace continuous flexural steel; it provides post-crack residual capacity in statically indeterminate ground-supported systems.
The micro fraction at 0.9 kg/m³ can provide fibre counts in the order of 1 × 10⁸ fibres per cubic metre, while the macro fraction at 4 kg/m³ supplies fibre counts several orders of magnitude lower. Consequently, the micro population governs early-age crack bridging, and the macro population governs post-crack toughness. This distinction is significant in mix design because reducing the micro fraction to lower raw-material cost without confirming plastic shrinkage performance under ASTM C1579-21 can leave the slab vulnerable to early surface cracking before sawcut joint activation.
In wet-mix sprayed concrete, the product is introduced at the batching plant or through calibrated conveying systems to maintain a homogeneous fibre distribution before the concrete reaches the nozzle. Sprayed concrete conformity is assessed under EN 14487-1:2005, and energy absorption class may be determined by panel testing under EN 14488-5 or beam testing under EN 14651. Synthetic macro fibres typically change the fresh-state rheology of a shotcrete mix; therefore sprayability, pumpability, and rebound should be validated in a pre-construction trial using the actual mixer and spraying equipment. Published full-scale comparative data on rebound reduction for this specific blend are limited, and the effect cannot be extrapolated from fibre type alone because nozzle type, accelerator dosage, and mix consistency dominate the rebound mechanism. The typical structural dosage for wet-mix shotcrete with a macro–micro synthetic blend falls in the 4–8 kg/m³ band, but the final value depends on the specified energy absorption class and ground support class.
Ground-supported slabs and external hardstandings use the same blend in the 3–6 kg/m³ range. The dual population addresses early-age plastic cracking before sawcut joint activation, while the macro fraction contributes to post-crack toughness and crack-width control around joints and corners. Design of synthetic fibre-reinforced slabs is often performed using Concrete Society Technical Report TR34 or equivalent local guidance, with material performance confirmed by beam tests under EN 14651 or ASTM C1609/C1609M. The slab thickness, joint spacing, subgrade stiffness, and loading regime are inseparable from the dosage decision; a higher fibre dosage does not compensate for inadequate joint layout or subgrade preparation.
Compared with hooked-end steel fibres, the synthetic blend has a specific gravity of approximately 0.90–0.92 versus 7.85 for steel. This reduces the added mass per cubic metre and simplifies bulk handling: a steel dosage of 30 kg/m³ adds about 30 kg per cubic metre, whereas a synthetic dosage of 5 kg/m³ adds about 5 kg per cubic metre. The elastic modulus of polyolefin macro fibres is two orders of magnitude lower than that of steel, so equivalent post-crack flexural performance at small crack widths is not obtained by mass-for-mass substitution. Performance-based comparison using EN 14651 or ASTM C1609/C1609M is required if steel replacement is contemplated. Synthetic fibres are not susceptible to chloride-induced corrosion, but they do not provide the same crack-clamping stress at service crack widths below 0.3 mm. The absence of metallic fibres can reduce surface rust discoloration in external slabs and can be relevant where floor coverings or food-handling areas require non-magnetic reinforcement.
Micro-only monofilament or fibrillated fibres are specified primarily for plastic shrinkage and settlement control, with dosages commonly between 0.6 kg/m³ and 1.8 kg/m³. They do not provide structural post-crack capacity at typical dosage levels because the individual fibres are too small to bridge macro-cracks. Macro-only synthetic fibres are dosed in the 3–8 kg/m³ range and provide post-crack toughness, but the lower fibre count per unit volume can leave early-age plastic cracking less controlled. The Novomesh 950 / SikaFiber Force 950 designation indicates a combined population, which is intended to cover both plastic-state and hardened-state requirements in a single product. Batch quality control should confirm that the micro fraction is not lost during open conveyor transfer and that the macro fraction remains uniformly distributed. Compliance documentation should include CE marking under the Construction Products Regulation 305/2011, REACH registration under EC 1907/2006, and any applicable RoHS Directive 2011/65/EU declarations.
Conformity for polymer fibres for concrete is evaluated under EN 14889-2:2006, which requires declaration of fibre geometry, tensile strength, modulus, alkali resistance, and effect on concrete strength. Factory production control is mandatory. ASTM-based specifications frequently reference ASTM C1116/C1116M for Type III synthetic fibre-reinforced concrete and ASTM C94/C94M for ready-mixed concrete.
| Standard or regulation | Scope | Document class |
|---|---|---|
| EN 14889-2:2006 | Polymer fibres for structural and non-structural concrete | CE certificate and factory production control |
| ASTM C1116/C1116M | Synthetic fibre-reinforced concrete specification | ASTM Type III classification |
| EN 14487-1:2005 | Sprayed concrete specification | Conformity of sprayed concrete |
| EN 14651:2005+A1:2007 | Residual flexural strength of fibre-reinforced concrete | Beam test report |
| ASTM C1609/C1609M | Flexural performance of fibre-reinforced concrete | Beam test report |
| ASTM C1579-21 | Restrained plastic shrinkage cracking | Comparative test report |
| 305/2011 | Construction Products Regulation | Declaration of performance and CE marking |
| EC 1907/2006 | REACH registration and safe use information | Safety data sheet and registration status |
| 2011/65/EU | RoHS restriction of hazardous substances | Compliance declaration |
Surface finishing of slab placements containing synthetic macro fibres requires adjustments to the work sequence. The fibres may become more visible at the surface if the concrete is overworked; trowel machines should be operated at a lower blade angle during initial finishing to avoid lifting fibres. Because the polymer fibres alter the bleed regime, curing should begin immediately after final troweling and should conform to ACI 308.1 or EN 13670. Premature sawcut jointing must be performed at the same time as plain concrete; fibre reinforcement does not eliminate the need for contraction joints.
Operational boundaries include fire resistance and high-temperature exposure. The polyolefin matrix softens in the 160–170 °C range, and vapour channels may form if the polymer is lost during fire. For applications where fire-induced spalling or structural fire resistance is critical, the mix must be tested under the applicable furnace standard, such as EN 1363-1 or EN 13501-1, and the fibre dosage must not be altered without retesting. Storage should prevent direct ultraviolet exposure and prolonged contact with strong oxidisers, because polymer degradation can reduce fibre tensile strength. The product is not a replacement for conventional reinforcement in structural elements where continuous tensile capacity is required by EN 1992-1-1 or ACI 318; its role is supplementary crack control and post-crack toughness in properly designed concrete sections.