Liwei Group Co., Ltd

Products

SikaFiber Novomesh B&BMA Macro - Engineered blend of macro and micro synthetic reinforcing fibre

    • Product Name: SikaFiber Novomesh B&BMA Macro - Engineered blend of macro and micro synthetic reinforcing fibre
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 557520
    Productname SikaFiber Novomesh B&BMA Macro
    Producttype Engineered blend of macro and micro synthetic reinforcing fibre
    Material Polypropylene
    Form Blend of macro and micro synthetic fibres
    Colour Grey
    Macrofibrelength Approximately 54 mm
    Microfibrelength Approximately 12 mm
    Fibrediameter Macro approximately 0.65 mm; micro approximately 0.03 mm
    Density Approximately 0.91 g/cm³
    Tensilestrength Approximately 600 MPa
    Youngsmodulus Approximately 9 to 10 GPa
    Meltingpoint Approximately 160 to 165 °C
    Ignitionpoint Greater than 360 °C
    Alkaliresistance High
    Waterabsorption Negligible
    Magneticproperties Non-magnetic
    Electricalconductivity Low
    Thermalconductivity Low
    Chemicalresistance Good
    Uvresistance Good
    Typicaldosage 4.5 kg/m³
    Packaging 10 kg bags
    Shelflife 24 months
    Storage Dry, protected from direct sunlight
    Standardcompliance EN 14889-2 and ASTM C1116

    As an accredited SikaFiber Novomesh B&BMA Macro - Engineered blend of macro and micro synthetic reinforcing fibre factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SikaFiber Novomesh B&BMA Macro is supplied in 1.5 kg water-soluble bags, packed 20 bags per carton, totaling 30 kg.
    Container Loading (20′ FCL) 20′ FCL container loading: palletized SikaFiber Novomesh B&BMA Macro, engineered macro/micro synthetic reinforcing fibre, securely loaded for shipment.
    Shipping SikaFiber Novomesh B&BMA Macro, an engineered blend of macro and micro synthetic reinforcing fibres, is shipped as a non-hazardous, non-regulated material. It is typically supplied in moisture-resistant bags or cartons on shrink-wrapped pallets. Store dry, avoid package damage, and transport under normal cargo conditions. No special transport precautions required.
    Storage Store indoors in original, unopened packaging in a cool, dry, well-ventilated area, away from direct sunlight, moisture, heat, open flames, and incompatible chemicals. Keep bags sealed, elevated on pallets, and protected from punctures, crushing, and contamination. Do not overstack. Use first-in, first-out rotation; handle per SDS and local regulations.
    Shelf Life Shelf life: 24 months from production when stored in original unopened packaging, dry, protected from direct sunlight, at moderate temperatures.
    Application of SikaFiber Novomesh B&BMA Macro - Engineered blend of macro and micro synthetic reinforcing fibre

    In logistics facilities where ground-supported slabs replace conventional steel mesh reinforcement with macro/micro synthetic fibre systems, SikaFiber Novomesh B&BMA Macro is batched at 3.0–5.0 kg/m³ into concrete complying with EN 206:2013+A2:2021 for a C30/37 or C35/45 mix with water-cement ratio held between 0.45 and 0.55 and slump class S3 (100–150 mm) for laser-screened placement. The microfibre component falls under Class I of EN 14889-2:2006, while the macrofibre component is specified as Class II under the same standard; acceptance testing additionally references ASTM C1116/C1116M-10a Type III synthetic fibre. In twin-shaft compulsory mixers with 2–3 m³ batch capacity, the documented failure mode is fibre balling when dry fibre is discharged too rapidly into the aggregate stream; corrective action requires automatic dosing after coarse aggregate charging and before the final 20% of mixing water, followed by 45–60 s of wet mixing after the last fibre addition. The slab is placed in long-strip pours with a laser screed and power-floated only after the bleed water sheen has disappeared, because early finishing can drag macrofibres to the surface and create local protrusion defects. Air content is controlled below 3.5% because the microfibre network interacts with entrained air and reduces trowelled surface density. The finished product is typically a 150–220 mm monolithic warehouse slab or high-bay logistics floor with saw-cut joints at 5.0–6.0 m centres; curing follows EN 13670:2018, with membrane-forming curing compounds applied at 200–250 g/m².

    What Changes When Macro and Micro Fibres Are Combined in Wet-Mix Shotcrete for NATM Excavation?

    Wet-mix sprayed concrete used for rock support under EN 14487-1:2005 incorporates the fibre system at 4.0–6.0 kg/m³ in a base mix normally classified as C25/30 to C30/37 with maximum aggregate size limited to 8–10 mm to prevent nozzle blockages. The fibre blend is batched at the concrete plant rather than at the nozzle; direct nozzle addition creates localised fibre concentration variations, although published data for this specific configuration is limited. The spraying process uses a wet-mix shotcrete pump with a rated output of 15–25 m³/h, equipped with a robotic arm in tunnel headings or slope stabilisation works. Pre-construction spray trials are required because rebound reduces retained fibre content, and the macrofibre fraction rebounds more than the microfibre fraction when nozzle air pressure is excessive; the governing trial parameter is retained energy absorption rather than laboratory flexural strength alone. The acceptance criterion is tested according to ASTM C1550-20 or EN 14488-5:2006, with energy absorption reported as joules at 40 mm central deflection; typical acceptance limits for temporary linings range from 300 J to 700 J depending on ground class. Accelerator compatibility must be verified with the specific alkali-free liquid accelerator dosage because rapid stiffening can encapsulate macrofibres before compaction and reduce residual flexural strength. The end product is an 80–150 mm sprayed concrete shell for NATM tunnel support, portal slope stabilisation, or rockfall protection; application is followed by sprayed curing compound within 15–20 min of final set to limit drying shrinkage.

    Precast plants operating carousel or battery mould systems for small-to-medium concrete elements add SikaFiber Novomesh B&BMA Macro at 2.0–3.5 kg/m³ to C40/50 concrete with a water-cement ratio not exceeding 0.45; the mix is produced in planetary mixers where fibre dispersion is stabilised by adding the fibre after 70% of the batch water has been charged. The governing product standard is EN 13369:2018, supplemented by EN 14889-2:2006 for fibre conformity and EN 206:2013+A2:2021 for concrete specification. Casting into steel moulds for drainage channels, culvert units, and utility troughs is carried out with high-frequency external vibration applied for 20–30 s per mould position; prolonged vibration beyond 45 s causes macrofibre float and weakens the top face. Demoulding is scheduled only after the cast element reaches a transfer strength of at least 15 MPa, and heat curing in the range of 50–60 °C is controlled to avoid thermal microcracking around the synthetic microfibre network. The end products are precast drainage channels, cable troughs, agricultural irrigation channels, and light-duty culvert sections where the fibre blend substitutes for light welded wire mesh and removes corrosion concerns during transport and installation.

    When Container Terminal Pavements Are Poured Joint-Free, the Dosage Window Narrows

    For external hardstandings designed according to Concrete Society TR34 or ACI 360R-10, SikaFiber Novomesh B&BMA Macro is dosed at 3.5–5.0 kg/m³, with the upper end reserved for continuous slabs exposed to laden reachstackers and side-lift container handlers. The concrete is specified as C35/45 with flexural toughness evaluated by ASTM C1609/C1609M-19a or EN 14651:2005+A1:2007, where the residual flexural strength after first crack verifies that the fibre contribution is maintained beyond the elastic limit. Slipform paving is used for long straight hauls with paving speeds of 0.8–1.2 m/min, while laser-screened placement remains common for irregular yard layouts; in both cases, saw-cut joints are placed at 5.0–6.0 m centres and must be opened within 18–24 h because delayed cutting after overnight strength gain produces uncontrolled mid-panel cracking. Field observations from intermodal yard pours show that edge slump and fibre exposure increase when the concrete exceeds slump class S3 during slipforming; the mix therefore uses a water-cement ratio near 0.42–0.48 and a high-range water reducer rather than additional water. The finished product is a heavy-duty container terminal pavement or intermodal hardstanding with thickness from 200 mm to 280 mm, designed for repeated point loads from container-handling equipment; curing is performed with a wax-based membrane-forming compound at 200 g/m² to maintain early-age moisture.

    ApplicationTypical dosage bandPrimary standardProcess equipmentEnd product type
    Monolithic warehouse slab3.0–5.0 kg/m³EN 14889-2:2006 / ASTM C1116/C1116M-10aTwin-shaft compulsory mixer, laser screed, power float150–220 mm high-bay floor
    Wet-mix shotcrete4.0–6.0 kg/m³EN 14487-1:2005 / ASTM C1550-20Robotic wet-mix shotcrete pump80–150 mm tunnel lining or slope shell
    Precast utility elements2.0–3.5 kg/m³EN 13369:2018 / EN 14889-2:2006Planetary mixer, vibrating table, carousel mouldDrainage channels, cable troughs, culvert units
    Intermodal hardstanding3.5–5.0 kg/m³TR34 / ASTM C1609/C1609M-19aSlipform paver or laser screed200–280 mm container yard pavement
    Bonded renovation overlay1.5–2.5 kg/m³EN 13813:2002 / EN 14889-2:2006Forced-action mixer, pump line, trowel30–50 mm bonded screed
    Agricultural slatted floor2.5–4.0 kg/m³EN 12737:2004+A1:2007 / EN 13369:2018Steel mould, vibrating table, strike-off templateSlatted floor panel, manure alley slab

    Where bonded screeds of 30–50 mm thickness are placed over existing concrete in renovation contracts, the fibre system is added at 1.5–2.5 kg/m³ to a pumpable screed mix conforming to EN 13813:2002; the macrofibre length is restricted to 0.5–0.75 of the screed thickness to prevent trowel streaking and surface roughness. The substrate is prepared by shotblasting or mechanical scabbling until the surface tensile strength reaches at least 1.5 MPa, and the bonding primer is applied immediately before the fresh screed to prevent cold joints. Mixing is carried out in forced-action mixers with a wet mixing time of 90–120 s; pumped application through 25–50 mm hose lines requires a slump flow of 180–220 mm, and the microfibre component reduces plastic settlement cracks at the bonded interface. Published energy absorption data for this specific grade at 1.5 kg/m³ in thin bonded overlays is limited; pre-qualification trials according to EN 13813:2002 are therefore required before specifying the product for structural renovation top layers. The end product is a bonded screed or renovation overlay that receives resin or cementitious coatings after curing, typically within 7 days, and the finished thickness is maintained within ±5 mm under a 2 m straightedge.

    Ammonia-Exposed Slatted Floor Panel Production Without Steel Reinforcement

    Precast slatted floor elements for swine and dairy housing are cast with SikaFiber Novomesh B&BMA Macro at 2.5–4.0 kg/m³ in concrete that complies with EN 13369:2018 and the product-specific standard EN 12737:2004+A1:2007 for floor slats for livestock. The fibre blend provides non-corroding crack control in manure alley environments, where steel reinforcement is vulnerable to chloride and ammonia attack; the microfibre fraction limits plastic shrinkage cracking during the first 6–8 h, while the macrofibre fraction improves post-crack residual strength under concentrated animal loads. The production process uses steel moulds mounted on vibrating tables; after filling, internal vibration is applied for 30–45 s, and the surface is struck off with a template to avoid excessive paste accumulation in the slat gaps. Curing is performed under polyethylene sheeting at 20–25 °C and 95% relative humidity for 7 days, because rapid drying promotes surface crazing that reduces ammonia resistance. The resulting end products are slatted floor panels, solid manure alley slabs, and dividing wall elements that are demoulded after reaching 12–15 MPa transfer strength and are stored for 28 days before installation.

    Free Quote

    Competitive SikaFiber Novomesh B&BMA Macro - Engineered blend of macro and micro synthetic reinforcing fibre prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    SikaFiber Novomesh B&BMA Macro is supplied as a dry engineered blend of macro and micro synthetic reinforcing fibres for placement in ready-mixed concrete, precast concrete, and wet-mix sprayed concrete. The macro component is a continuously embossed polyolefin monofilament with a nominal length of 40 mm to 54 mm and an equivalent diameter of 0.3 mm to 0.8 mm; the micro component is a monofilament or fibrillated polyolefin fibre with a nominal length of 6 mm to 12 mm. The blend is classified as a polymer fibre for structural use under EN 14889-2:2006 and falls within the Type III synthetic fibre definition of ASTM C1116/C1116M-10a. The macro fraction mobilises after matrix cracking to provide residual flexural strength and energy absorption; the micro fraction reduces plastic shrinkage cracking, plastic settlement, and bleed-water channelling during the initial 24 h after placement.

    Published data for this specific branded configuration is limited; when current manufacturer technical data sheet values are unavailable, class-level ranges for synthetic macro and micro fibre systems are used for proportioning and performance verification. The B&BMA Macro designation identifies the macro fraction as the primary post-crack reinforcement, while the micro fraction is present for early-age crack control rather than structural load transfer.

    In twin-shaft compulsory mixers with nominal batch capacities between 1.5 m³ and 4.5 m³, the blend is charged after the aggregates and before the mixing water. A post-fibre mixing interval of 30–60 s is generally sufficient for visual homogeneity at batch temperatures below 30 °C. Fibre-ball formation has been observed on production lines when free moisture on coarse aggregate exceeds 3% and the fibres are dosed before the aggregate stream has fully covered the mixer flights. The monofilament micro fraction in this blend reduces static-charge clustering compared with fibrillated-only micro fibre, but vibratory feeder discharge rates above 12 kg/min can still create transient concentration gradients in the aggregate transfer belt.

    For truck-mixer addition, the blend is introduced at a minimum mixing speed of 12 rpm to 18 rpm for at least 5 min after the last bag is added. Worn mixing blades and hardened concrete build-up on drum walls can increase fibre accumulation; routine washout inspection is recommended in continuous production. No pre-drying of the polyolefin fibre is required at relative humidity up to 80% and storage temperature below 50 °C. The polyolefin is hydrophobic and does not initiate corrosion, but oil contamination from conveyor belts can reduce fibre-matrix bond and should be excluded from the batching path.

    In pumped concrete, the macro fibres align preferentially with the concrete flow direction through 125 mm to 150 mm internal diameter hoses. Obstruction is generally absent at dosages up to 5.0 kg/m³ when the mortar phase is cohesive and the coarse aggregate content is reduced by 2–5% by volume. Fibre addition increases apparent yield stress; maintaining a target slump of 150±30 mm commonly requires an additional 0.5–1.5% high-range water reducer by mass of cementitious material over the control mix.

    What limits dosage selection for slabs and sprayed concrete?

    Dosage is governed by the required post-crack residual flexural strength, the plastic shrinkage crack-control objective, and the fresh concrete placement method. Manufacturer-published guidance for this blended system generally places total dosage between 2.5 kg/m³ and 5.0 kg/m³ for ground-supported slabs and between 3.5 kg/m³ and 6.0 kg/m³ for wet-mix sprayed concrete. Dosages below 2.5 kg/m³ can still reduce early-age cracking through the micro component but often do not produce repeatable post-crack performance under EN 14651 beam testing. In concretes with cementitious content below 350 kg/m³, dosages above 6.0 kg/m³ have been associated in field reports with pump pressure increases of 20–35% and a slump-flow reduction from 600 mm to 450 mm in self-consolidating mixtures.

    The lower dosage boundary is also limited by the surface area of the micro component required to intercept bleed-water channels. In slab batches with low fines content, micro fibre addition below 0.9 kg/m³ may not provide measurable plastic shrinkage crack reduction under ASTM C1579-21; the blend formulation should therefore be selected so that the micro fraction reaches at least this threshold before the macro dosage is optimised for hardened-state performance.

    For sprayed concrete, dosage confirmation is performed through plate-type energy absorption testing under EFNARC 1999 or ASTM C1550. A specified plate energy absorption of 700 J at 25 mm central deflection is frequently achieved with synthetic macro fibre dosages between 3.0 kg/m³ and 6.0 kg/m³; class-level results depend on aggregate gradation, accelerator chemistry, and nozzle air-flow energy. The use of an equivalent steel fibre dosage without beam or plate validation is not acceptable.

    A direct substitution of steel fibre with an equivalent mass of synthetic macro fibre is not valid. Steel fibre and synthetic macro fibre operate through different tensile modulus, aspect ratio, and bond mechanisms and therefore require separate dosage and design verification. The following table summarises representative published property ranges for fibre classes rather than product-specific acceptance values.

    Representative class-level properties for steel macro fibre, synthetic macro fibre, and micro synthetic fibre
    PropertySteel macro fibreSynthetic macro fibreMicro synthetic fibre
    Density7850 kg/m³910–920 kg/m³910–920 kg/m³
    Young’s modulus200 GPa3–10 GPa3–8 GPa
    Tensile strength1000–1500 MPa350–600 MPa300–400 MPa
    Post-crack strength mechanismHigh modulus mobilises at narrow crack widthsLower modulus requires larger crack opening for full engagementNot intended for structural post-crack resistance
    Plastic shrinkage crack controlLimitedModerateHigh
    Pump-line wearHighLowLow

    Against a micro-only fibre product, the macro fraction in this blend supplies residual flexural strengths that are typically reported between 1.0 MPa and 3.5 MPa at CMOD 0.5 mm under EN 14651 at dosages of 3.0–5.0 kg/m³. Micro-only fibres generally do not provide measurable residual flexural strength above 0.5 MPa at the same crack opening in concrete with matrix strength 30–40 MPa. Against a straight macro synthetic product, the presence of the micro component reduces early-age crack width under restrained shrinkage testing, but it does not increase the post-crack toughness beyond the macro fibre dosage contribution.

    Compared with welded wire mesh, the synthetic fibre blend is distributed in three dimensions rather than a single plane, but it is not a substitute for conventional longitudinal reinforcement in primary flexural members unless explicitly designed using residual strength models. The blend is applicable to ground-supported slabs, overlays, and sprayed concrete linings where crack-width control, post-crack ductility, and corrosion resistance are the governing requirements.

    During power trowelling of ground-supported slabs, surface protrusion of macro fibres can occur when bleed water is closed too early. The operational boundary is to delay trowelling until the bleed water sheen has disappeared and to avoid rapid surface drying. Protruding fibres can be removed by mechanical saw cutting or are enclosed by subsequent floor coverings; they do not present a corrosion staining issue.

    In precast concrete, the blend is used in secondary elements where demoulding and handling stresses require crack-width control and improved impact resistance. The fibre does not affect early-age heat of hydration or set time, but it can reduce visible surface void area when used with an appropriate external vibration regime of 50–80 Hz for 20–40 s per form section. Impact resistance in slab-on-grade applications is typically evaluated under ACI 544.2R-17 repeated impact testing; synthetic macro fibre blends increase the number of blows to first crack and failure over plain concrete.

    When wet-mix sprayed concrete is specified without welded wire mesh

    Wet-mix sprayed concrete producers have used synthetic macro fibre blends to replace welded wire mesh in temporary and permanent linings where corrosion protection and rebound reduction govern. In wet-mix equipment with accelerator injection at the nozzle, the fibre blend is introduced at the weigh batcher or truck mixer, not through the nozzle. The maximum aggregate size is generally 40 mm; the macro fibre length and aggregate size are selected so that fibre length does not exceed 0.4 times the pump hose internal diameter. For a 50 mm internal diameter nozzle hose, fibre length is therefore limited to approximately 30–40 mm. Longer macro fibres at higher dosages can induce nozzle pulsation and blockages when accelerator dosage exceeds 6% by mass of binder.

    The lower density of synthetic fibre reduces rebound compared with steel fibre, but rebound mass depends on air flow, accelerator dose, and nozzle angle. Field reports from sprayed concrete operations indicate that steel fibre rebound can exceed 25% under adverse conditions, while synthetic macro fibre rebound commonly remains between 10% and 20%; published data for this specific blended configuration is limited. The micro fraction improves cohesion and reduces mix drainage, which is particularly relevant in overhead spraying. The polyolefin blend is inert in the alkaline sprayed concrete environment and does not interfere with alkali-free or sodium silicate accelerated systems.

    Quality assurance under EN 14889-2 and related test standards

    The product is acceptable for structural use only when the batch certificate lists the actual fibre length distribution, the melt-flow index of the base polyolefin component, and the declared dosage for the specified toughness class. The melt-flow index is controlled under ISO 1133-1:2022; values outside the manufacturer’s declared interval can alter fibre deformation behaviour during extrusion and change concrete workability. No volatile organic solvent or amine-based surface treatment is known to be present in this blend. Compatibility with air-entraining admixtures should be tested because hydrophobic synthetic fibres can temporarily adsorb air-entraining surfactants and reduce the air void spacing factor under ASTM C457.

    Standards and acceptance criteria relevant to synthetic fibre blends in concrete
    ScopeStandard or guideTypical criterion or output
    Polymer fibre classification and CE markingEN 14889-2:2006Declared geometry, dosage, and Class I/II modulus classification
    Post-crack flexural performanceEN 14651Residual flexural strength at CMOD 0.5 mm, 1.5 mm, 2.5 mm, 3.5 mm
    Plastic shrinkage crackingASTM C1579-21Crack width reduction compared with control at 24 h
    Concrete fibre classificationASTM C1116/C1116M-10aType III synthetic fibre classification
    Wet-mix sprayed concreteEFNARC 1999 / ASTM C1550Plate energy absorption at 25 mm central deflection

    For production acceptance, beam specimens 150 mm × 150 mm × 550 mm are cast under external vibration at 50 Hz, with a notch depth of 25 mm for EN 14651. A closed-loop servo-hydraulic testing frame with crack mouth opening displacement control at 0.05 mm/min for the first 0.1 mm and 0.2 mm/min thereafter is used. The first batch of each mix design is tested at the target fibre dosage, the lower-bound dosage, and the upper-bound dosage to define the operational tolerance window before production runs begin.

    The polyolefin fibre is inert under REACH registration obligations and is not classified as hazardous under CLP. No RoHS restricted substance is present in the synthetic fibre concentrate above the maximum concentration values. These statements apply to the polymer fibre component and do not extend to the concrete admixture system.