| HS Code | 243081 |
| Productname | SikaFiber PPM 48/19 - Hybrid Fibre (Macro & Micro Blend) |
| Producttype | Hybrid synthetic fibre |
| Fibreblend | Macro and micro polypropylene fibres |
| Macrofibrematerial | Polypropylene |
| Microfibrematerial | Polypropylene |
| Macrofibrelength | 48 mm |
| Microfibrelength | 19 mm |
| Macrofibrediameter | 0.9 mm |
| Microfibrediameter | 0.03 mm |
| Macrofibreaspectratio | 53 |
| Microfibreaspectratio | 633 |
| Density | 0.91 g/cm³ |
| Macrofibretensilestrength | 500 MPa |
| Microfibretensilestrength | 300 MPa |
| Macrofibreelasticmodulus | 5 GPa |
| Microfibreelasticmodulus | 3 GPa |
| Meltingpoint | 160-170 °C |
| Ignitionpoint | >350 °C |
| Alkaliresistance | High |
| Waterabsorption | Nil |
| Dosage | 3-9 kg/m³ |
| Packaging | 10 kg bag |
| Shelflife | 5 years |
| Storageconditions | Dry, protected from direct sunlight |
| Colour | Grey |
| Standards | EN 14889-2, ASTM C1116 |
As an accredited SikaFiber PPM 48/19 - Hybrid Fibre (Macro & Micro Blend) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber PPM 48/19 is supplied in 10 kg moisture-resistant paper bags, palletized for convenient handling and dosing. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): SikaFiber PPM 48/19 Hybrid Fibre (Macro & Micro Blend), palletized and secured for safe sea transport. |
| Shipping | SikaFiber PPM 48/19 Hybrid Fibre (Macro & Micro Blend) ships as non-hazardous, non-regulated cargo. Use original sealed bags on pallets; protect from moisture, punctures, and contamination. No UN number, hazard class, or packing group applies. Follow SDS, local transport rules, and standard dust-control PPE. |
| Storage | Store in a cool, dry, well-ventilated area, away from moisture, direct sunlight, heat, ignition sources and incompatible materials. Keep original packaging closed, elevated off floors, and protected from physical damage. Maintain stable temperatures, avoid extreme conditions, and follow first-in, first-out stock rotation. Ensure containers are labelled, kept out of reach of children, and reseal partially used bags. |
| Shelf Life | Shelf life is 24 months from production when stored dry in original, unopened packaging; protect from moisture and extreme temperatures. |
Automated warehouse slab-on-grade concrete is dosed with SikaFiber PPM 48/19 at 3.0 kg/m³ to 5.5 kg/m³ to control early-age plastic shrinkage cracking through the micro-mono component and to supply post-crack residual strength through the macro component. The hybrid fibre is dispersed during a 90-second minimum high-shear mixing period after complete batch water addition, while the micro fibre is introduced with aggregates or cement. Concrete slump should be adjusted to 150 mm to 180 mm for pump placement and laser screed strike-off, and the finishing sequence is limited to single-pass power trowelling at 45 rpm to avoid fibre protrusion. Plastic shrinkage cracking is compared using ASTM C1579-21; flexural toughness is recorded using ASTM C1609/C1609-19 and EN 14651 with three-point beam loading at CMOD = 0.5 mm and CMOD = 3.5 mm. The product is classified as a synthetic macro-micro blend according to EN 14889-2 and ASTM C1116/C1116-23 Type III synthetic fibre-reinforced concrete. Operational boundaries: the hybrid fibre does not replace structural steel reinforcement in slab regions with negative bending moments unless explicitly designed with residual flexural capacity; concrete containing macro fibres at doses above 5.5 kg/m³ may show reduced workability requiring polycarboxylate ether superplasticizer adjustment; curing compound application must not trap fibres at the surface under power-trowel finish conditions.
Wet-cast precast box culverts and manhole sections are dosed between 4.0 kg/m³ and 6.0 kg/m³ to reduce edge cracking during stripping and to provide impact resistance during transport and installation. The macro component contributes residual flexural capacity after first crack, while the micro component lowers early-age settlement cracking around knockouts and cast-in inserts. Formwork vibration is maintained at 80 Hz to 120 Hz using external vibrators, and the demoulding window after heat curing is adjusted to achieve concrete compressive strength of 12 MPa to 15 MPa before lifting. Fibre material compliance follows EN 14889-2; concrete compliance follows EN 206; the fibre-reinforced concrete designation follows ASTM C1116/C1116-23 Type III. Post-cracking flexural capacity is validated using EN 14651 at CMOD = 1.5 mm; for buried applications, the designer may reference fib Model Code 2010 residual flexural strength class. Operational boundaries: doses below 4.0 kg/m³ do not reliably provide edge-arresting residual capacity in 40 mm to 60 mm thick wall sections; the macro fibres are added to the aggregate conveyor rather than the water batcher to avoid balling; concrete discharge temperature should remain below 25°C to prevent viscosity increase during long haul times.
At the tunnel face, wet-mix shotcrete receives the hybrid fibre at 4.0 kg/m³ to 7.0 kg/m³ to reduce rebound losses and improve early-age cohesion while the macro component provides energy absorption after a lining crack forms. The concrete is delivered through a screw feed or piston shotcrete machine with a 38 mm to 50 mm delivery hose and a 12 bar to 16 bar nozzle air pressure; accelerator is introduced at the nozzle to achieve a 1-minute to 3-minute set time, and the inclusion of micro fibres stabilises pump pressure by reducing bleed in the hopper. Lining performance is verified using EN 14488-3 for flexural toughness and EN 14488-5 or ASTM C1550-20 for round panel energy absorption. A specified dosage of 5.5 kg/m³ typically requires an adjusted accelerator dose because fibre surfaces increase paste viscosity. Operational boundaries: at dosages above 7.0 kg/m³, pump pressure may exceed 60 bar unless aggregate packing is re-tuned; the mix should not be placed at a temperature below 5°C unless heated materials are used; steel reinforcement may be omitted only where the lining is designed using fracture mechanics parameters, not by equal-volume replacement of steel fibres.
| Application segment | Typical dosage | Primary performance standard | Key processing limit |
| Industrial slab-on-grade | 3.0–5.5 kg/m³ | ASTM C1609/C1609-19, EN 14651 | Single-pass power trowel finish |
| Wet-cast precast culverts and manholes | 4.0–6.0 kg/m³ | EN 14651, ASTM C1116/C1116-23 | Discharge temperature 25°C |
| Wet-mix shotcrete lining | 4.0–7.0 kg/m³ | EN 14488-3, ASTM C1550-20 | Pump pressure 60 bar at upper dose |
| Composite steel deck topping | 2.5–5.0 kg/m³ | ASTM C1609/C1609-19, EN 14889-2 | Slump 180–220 mm at pump |
| Precast tunnel segments | 4.0–6.5 kg/m³ | EN 14651, fib Model Code 2010 | Injection port ≥ 60 mm |
| Marine splash-zone and water-retaining concrete | 4.0–6.0 kg/m³ | EN 1992-1-1, EN 206 | w/c ≤ 0.45 |
When pumped onto re-entrant steel deck profiles, the topping concrete receives SikaFiber PPM 48/19 at 2.5 kg/m³ to 5.0 kg/m³ to replace conventional anti-crack mesh that is difficult to fix within 50 mm to 80 mm cover depths above the deck flute crown. The micro component limits early-age plastic shrinkage cracking during high air movement and low humidity conditions; the macro component provides residual tensile capacity around shear studs and edge details. Pumping through a boom placer is typically limited to 150 m horizontal reach with 125 mm pipeline diameter because entrained air and fibre aspect ratio affect concrete velocity. The topping concrete is specified to EN 206 and EN 14889-2; flexural performance is tested according to ASTM C1609/C1609-19; slab bonding to steel deck is confirmed by pull-off testing per EN 1542 or ASTM C1583/C1583-13. The system is not designed to replace mesh in negative moment zones over girders unless the structural engineer specifies a residual flexural strength class. Operational boundaries: concrete slump at the pump should be 180 mm to 220 mm, preferably with a polycarboxylate ether superplasticizer to avoid bleed; if the micro fibre is not fully dispersed, fibres may collect at the top surface and interfere with trowel finishes.
Precast tunnel segment moulds demand a fibre blend that can be compacted into 200 mm to 350 mm thick segments without segregating in narrow moulds. SikaFiber PPM 48/19 is incorporated at 4.0 kg/m³ to 6.5 kg/m³ in self-consolidating or highly fluid concrete with a slump flow of 600 mm to 750 mm. The macro fibres improve residual flexural capacity during demoulding and ring erection; the micro fibres reduce segregation and plastic settlement around gasket grooves and bolt pockets. The concrete is mixed in a twin-shaft compulsory mixer with a 300-second total cycle after fibre addition, then placed under 2 g to 4 g vibration for 15 seconds to 30 seconds per segment. Post-crack performance is characterised using EN 14651 and fib Model Code 2010 residual strength class, with acceptance typically evaluated at CMOD = 0.5 mm and 3.5 mm. Operational boundaries: fibre content above 6.5 kg/m³ can obstruct flow through mould injection ports smaller than 60 mm in diameter; concrete temperature is maintained between 10°C and 25°C to prevent viscosity increase; the blend must be added after aggregate moisture correction and before superplasticizer adjustment to avoid fibre balling.
Chloride ingress and wet-dry cycling in marine splash-zone concrete call for the hybrid fibre at 4.0 kg/m³ to 6.0 kg/m³ to limit crack widths and reduce the risk of chloride-induced corrosion of embedded steel, although the micro fibres are primarily intended to suppress plastic shrinkage cracking in the first 24 hours after casting. The structural concrete is specified to EN 206 exposure classes XS2/XS3 or XD2/XD3, with a water-to-cement ratio capped at 0.45 and minimum cement content of 340 kg/m³. Crack width control is checked using EN 1992-1-1 formulae and, if required, ASTM C1609/C1609-19 residual strength data are used to justify reduced conventional reinforcement in non-structural walls. The macro component improves resistance to impact from floating debris and maintenance loads, while the non-corroding nature of the hybrid fibre avoids rust staining associated with steel fibre at exposed surfaces. Testing for chloride migration in cracked concrete follows NT Build 492 or ASTM C1202, but the fibre influence on chloride diffusion is indirect through crack control rather than chemical modification. Operational boundaries: the material is not a corrosion inhibitor and does not justify reducing cover below the values required by EN 1992-1-1 or ACI 318-19; it must be combined with a low-permeability concrete matrix and high-quality curing; no performance claim can be extrapolated from round panel energy absorption to chloride resistance without a trial batch using the actual aggregate source.
Competitive SikaFiber PPM 48/19 - Hybrid Fibre (Macro & Micro Blend) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Batching plant experience indicates that the two length fractions respond differently to mixer geometry. In a compulsory twin-shaft mixer with a capacity of 1.5 m³ to 3.0 m³, the 19 mm microfibre fraction disperses rapidly through the fine aggregate and cement paste, while the 48 mm macrofibre fraction requires mechanical collision against coarse aggregate to separate individual filaments. Addition directly onto dry cement before aggregate feed creates localised low-moisture clumps, because the hydrophobic surface of virgin polypropylene repels the initial water and prevents immediate wetting. The preferred batching sequence is to add fibres after the coarse and fine aggregates have been chuted and lightly mixed, then introduce cement and water. In pan mixers with high-speed rotor, visual homogeneity under EN 12350-1:2019 sampling is usually achieved after 120 s to 180 s of wet mixing after fibre addition. In free-fall drum mixers, the maximum practical dosage before persistent balling occurs is often below 3 kg/m³. A field-adjusted rule observed on several precast and ready-mix lines is to inspect for macrofibre tails protruding from the concrete surface immediately after discharge; their presence is not necessarily a dispersion failure, but it can indicate insufficient mixing time or addition too late in the cycle. On a 2.5 m³ planetary mixer with a 55 kW main drive, increasing the dosage from 2 kg/m³ to 5 kg/m³ raises mixing bowl amperage by approximately 8% to 12% for a crushed granite mix with a nominal maximum aggregate size of 20 mm. Published data for this specific configuration is limited, but the trend is consistent with increased interparticle friction from the macrofibre network. The slump reduction observed at higher dosages is typically 10 mm to 30 mm when tested under EN 12350-2:2019; with a polycarboxylate ether superplasticizer, an additional 0.1% to 0.3% by weight of cement usually restores the target consistency. Air-entraining admixtures may interact differently, because the longer macrofibres can reduce the stability of entrained air bubbles in mixes near the upper air-content limit. A trial batch under ASTM C231/C231M-17a is therefore recommended when freeze-thaw durability is governed by air void spacing.
Sprayed concrete for temporary underground support is one application where the hybrid macro/micro blend is used instead of macro-only fibres or conventional steel fibres. In wet-mix shotcrete, the fibre blend is pre-mixed into the concrete truck or pan, then transported through a piston pump with 50 mm to 65 mm delivery lines and projected with compressed air. The 48 mm fraction is close to the upper length envelope for reliable passage through 50 mm hose and through elbows with radius-to-diameter ratios tighter than 250 mm. At dosages above 4 kg/m³, pumping pressure increases by 1 bar to 3 bar relative to the same mix without macrofibres, particularly when the concrete is viscous or the ambient temperature is below 5 °C. The 19 mm microfibre fraction improves paste film quality and reduces segregation, but it does not fully offset the pressure increase caused by the macrofibres. In the nozzle and rebound zones, the low density of polypropylene reduces rebound losses compared with steel fibres when measured under EN 14488-1:2005. Rebound is controlled more strongly by nozzle distance, air volume, and concrete rheology than by fibre type; a well-adjusted nozzle typically yields rebound values below 10%, while poor air adjustment can exceed 25% regardless of fibre material.
Energy absorption in fibre-reinforced shotcrete is assessed on square or round panel specimens under EN 14488-5:2006. The hybrid blend is typically dosed at 3 kg/m³ to 6 kg/m³ to achieve energy absorption classes in the range 500 J to 1000 J at 25 mm central deflection, but the exact value depends on matrix compressive strength, aggregate shape, accelerator type, and pumping distance. Published project results for this specific blend should be obtained before specifying an energy absorption class above 700 J, because high deflection thresholds can exceed the post-crack capacity of synthetic macrofibres alone. For early-age cracking in sprayed concrete, the 19 mm microfibre fraction reduces the crack area measured under ASTM C1579-21; however, this does not eliminate the need for curing compound, fog misting, or tunnel ventilation to control evaporation. Polypropylene fibres are compatible with alkali-free shotcrete accelerators and do not react with set accelerators; they are neutral to the hydration chemistry. The main incompatibility concern is not chemical but physical: dry-mix equipment with fibre pre-blending requires higher air flow to carry the low-density macrofibres through the rotary feed, and blockages can occur if the feed bowl is overfilled. Published data for specific accelerators is limited, but the fibre polymer matrix is not known to interfere with aluminium sulfate-based alkali-free accelerators.
The comparative function of the hybrid blend becomes evident in slab-on-grade and external hardstanding applications. A macro-only polypropylene fibre of similar length provides post-crack flexural resistance but has a relatively low fibre count per unit mass, so it does not reliably suppress plastic shrinkage cracking. A microfibre-only product generates a high count of fine filaments and limits early-age crack width, but it is not intended to carry post-crack flexural loads. The hybrid combines the two functions in one package and thereby reduces the need for two separate fibre additions. Compared with steel fibre, the polypropylene hybrid has a density approximately one-eighth that of steel; this reduces transport mass, pumping abrasion, and mixing wear, and eliminates corrosion-induced popping or staining in exposed slabs. The synthetic fibre is non-magnetic and does not interfere with electromagnetic induction loops, radar, or radio-frequency identification systems embedded in floors. However, polypropylene has a tensile modulus more than an order of magnitude below that of steel. As a consequence, under ASTM C1609/C1609M-19a, the synthetic macrofibre fraction yields lower residual flexural strength at L/600 and L/150 deflections than hooked-end steel fibre at the same weight dosage. The synthetic hybrid is therefore specified for crack-width control, plastic shrinkage reduction, and durability enhancement, not for full structural replacement of steel fibre where the design relies on residual flexural strength ratios above 30%. When steel fibre is replaced with this hybrid at equal volume, the slab design must be re-evaluated; a 1:1 weight substitution is unsafe because the two fibre types have different tensile properties and anchorage mechanisms.
| Parameter | SikaFiber PPM 48/19 | Macro-only PP | Steel fibre |
|---|---|---|---|
| Fibre length distribution | 48 mm + 19 mm | 48 mm only | 30–60 mm |
| Density | 0.91 g/cm³ | 0.91 g/cm³ | 7.85 g/cm³ |
| Early-age plastic shrinkage control | high due to microfibre count | limited | limited |
| Post-crack residual flexural capacity | moderate | moderate | high |
| Corrosion risk in chloride-exposed slab | none | none | possible rust staining |
| Conductive/magnetic signature | non-magnetic | non-magnetic | magnetic/conductive |
| Mixer and pump wear | low | low | higher |
The above comparison is qualitative at the product-class level and should not be used for structural design without project-specific testing. For structural projects, fibre performance is determined by third-party test data under ASTM C1609/C1609M-19a, EN 14651:2005, or EN 14488-5:2006, depending on the application. The hybrid blend may be accepted in specifications where both early-age crack reduction and post-crack energy absorption are required in a single product. However, published data for direct substitution ratios is limited, and site trials should establish the appropriate dosage for the specific concrete matrix.
Precast concrete manufacturers have used hybrid synthetic fibres in non-structural architectural panels, utility vaults, and tunnel segments where handling stresses and early stripping expose concrete to cracking before it reaches full design strength. The microfibre fraction reduces plastic shrinkage cracking during the first 12 h, while the macrofibre fraction provides limited post-crack resistance during demoulding and handling. In precast plants with carousel systems and inductive heating, the non-magnetic and non-conductive fibre is compatible with embedded sensors and does not generate hot spots in the concrete. The batching sequence in a precast plant commonly places dry fibres into a skip after sand and aggregate but before cement, followed by a 60 s to 90 s high-shear mix. Quality control includes fibre content verification by washout on fresh concrete; the fibre volume is expressed in kg/m³ or fibres per litre. Fibre count data for a 48 mm macrofibre and 19 mm microfibre blend are more variable than for steel fibres because the low-density polymer fibres are harder to recover fully during washout and because sample splitting can underrepresent the macrofibre fraction. The coefficient of variation for fibre count on production floor samples may range from 10% to 20%; published data for this specific blend is limited. Therefore, acceptance should be based on the manufacturer’s batch certificates for fibre length distribution and dosage, combined with periodic fresh-state sampling.
The hybrid blend is supplied in bags or bulk sacks with a moisture content below 0.1% by mass; the fibre itself does not absorb water, and bags should be kept closed to prevent contamination by cement dust, aggregate fines, or organic debris. Storage should be indoor, protected from direct sunlight, and below 40 °C to avoid polymer oxidation and stabiliser depletion. Shelf life from the production date is commonly stated as 24 months when stored in the original unopened package; after that period, the fibre may still be usable if tensile strength and elongation meet original specification under ISO 13934-1:2013 or equivalent. The product is assessed under EN 14889-2:2006 for polymer fibres in concrete; the hybrid bimodal nature means that the macrofibre fraction may be evaluated under the macrofibre provisions and the microfibre fraction under the microfibre provisions. Fibre length, count, specific gravity, and alkali resistance are part of the manufacturer’s declaration. The product is registered under REACH Regulation (EC) No 1907/2006 where required for European Union supply. It does not contain intentionally added cadmium, lead, or hexavalent chromium above the thresholds in RoHS Directive 2011/65/EU, although RoHS applies to electrical and electronic equipment and is not the governing regulation for construction fibres.
| Property | Standard designation | Typical value or requirement |
|---|---|---|
| Fibre length distribution | EN 14889-2:2006 | 48 mm macro / 19 mm micro |
| Specific gravity | ISO 1183-1:2019 | 0.91 g/cm³ |
| Melting temperature | ISO 3146:2019 | 160–165 °C |
| Alkali resistance | EN 14889-2:2006 | no degradation in alkaline pore solution |
| Flexural performance | ASTM C1609/C1609M-19a | project-specific residual strength |
| Shotcrete energy absorption | EN 14488-5:2006 | 500–1000 J at 25 mm deflection at 3–6 kg/m³ |
| Plastic shrinkage cracking | ASTM C1579-21 | reduction vs plain concrete |
| Chemical registration | REACH Regulation (EC) No 1907/2006 | registered |
Operational boundaries require attention. At dosages above 6 kg/m³, conventional mixer dispersion is not guaranteed, and the fibre volume fraction may create workability loss, pump pressure spikes, or surface finish defects. Air-entrained concrete for exterior exposure under ASTM C666/C666M-15 should be monitored because the macrofibres increase the apparent yield stress and may reduce the spacing factor of entrained air voids. The product is not intended for use in structural members where the structural design relies on steel fibre or deformed bar reinforcement to carry primary tensile forces. For fire-resistance design, polypropylene fibres melt at approximately 160 °C and the product should not be credited with residual load capacity at high temperatures; in tunnel linings, polypropylene fibres are sometimes used to reduce explosive spalling by creating microchannels after melting, but this function is a separate design consideration and must be verified under fire test standards such as EN 13501-2:2016. In contact with strong oxidising agents, aromatic hydrocarbons, or prolonged service temperatures above 100 °C, polymer embrittlement or softening may occur. In dry-mix spraying, airborne fibres require local exhaust ventilation and respiratory protection to maintain occupational exposure below applicable national limits. When the fibre blend is used in acid-resistant concrete, the acid resistance is governed by the cementitious binder and aggregate, not by the fibre; published data for prolonged exposure to sulfuric acid at concentrations above 5% is limited. The product should be evaluated by trial batching and site-specific performance testing before inclusion in any project specification.