| HS Code | 447878 |
| Product Name | STRUX M323 (Adfil Strux M323) |
| Product Type | Synthetic Fiber Blend |
| Material Composition | Polypropylene and polyethylene blend |
| Fiber Type | Macro synthetic fiber |
| Fiber Length | 40 mm |
| Fiber Diameter | 0.8 mm |
| Aspect Ratio | 50 |
| Tensile Strength | 550 MPa |
| Elastic Modulus | 7 GPa |
| Density | 0.91 g/cm³ |
| Melting Point | 160 °C |
| Alkali Resistance | Excellent |
| Dosage | 3-6 kg/m³ |
| Packaging | 5 kg bags |
| Color | Grey |
| Water Absorption | Nil |
| Chemical Resistance | Good |
| Uv Resistance | Good |
As an accredited STRUX M323 (Adfil Strux M323) - Synthetic Fiber Blend factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 10 kg moisture-resistant paper bags, typically palletized for bulk delivery; quantity: 10 kg per bag. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): STRUX M323 synthetic fiber blend, palletized and securely stowed in a 20-foot full container load. |
| Shipping | STRUX M323 (Adfil Strux M323), a synthetic fiber blend, is typically shipped as a non-hazardous, non-regulated material. It is supplied in moisture-resistant bags or boxes on pallets. No special transport classification is required. Keep dry, avoid package damage, and store under cover per standard handling practices. |
| Storage | Store STRUX M323 in a cool, dry, well-ventilated area in original, unopened packaging. Keep off the ground, away from moisture, direct sunlight, heat, ignition sources, and incompatible chemicals. Maintain sealed bags to prevent contamination. Use first-in, first-out stock rotation. Protect pallets from damage and excessive stacking. Follow supplier safety data sheet and local regulations. |
| Shelf Life | Shelf life is 24 months from manufacture when stored unopened in original packaging, in dry, cool conditions, away from direct sunlight. |
In warehouse floor slabs cast on grade, Adfil STRUX M323 is incorporated at 4.0 kg/m³ to 6.0 kg/m³ when the specification removes welded wire mesh and seeks a jointless or wide-joint slab. The mix is typically a C30/37 concrete with a maximum aggregate size of 20 mm, a water-to-cement ratio below 0.50, and a target S3 slump under EN 12350-2. Fibers are added to a twin-shaft compulsory mixer after aggregates and before the polycarboxylate ether superplasticizer; the mixing cycle is extended by 45–60 s after fiber addition to prevent balling at the feed point. The key distinction is that the flexural strength of the uncracked matrix is governed by the paste and aggregate interlock, whereas the post-crack residual capacity is supplied by the fiber blend and must be verified by beam testing under ASTM C1609/C1609M-19a at a net deflection of L/150, not by a visual inspection of crack width in the finished slab. For racking legs with high point loads, the floor design is recalculated using a residual strength ratio rather than a lump-sum mesh equivalence; specifications that merely state “replace one layer of welded wire mesh” without defining the residual strength class introduce uncontrolled variance into joint stability. Saw-cutting is performed at 24–36 h after casting, and joint spacing beyond 9 m requires a subgrade friction analysis and a reduced restraint detail; the fiber blend does not eliminate the need for crack-inducing contraction joints in restrained slabs. Shrinkage strain development is assessed with ASTM C1581/C1581M-18a ring tests, and the dosage is typically increased only after the restrained cracking age has been compared for the exact cement content and slab thickness. Slump loss after fiber addition becomes measurable when addition crosses 6.0 kg/m³; the batch is compensated with a high-range water reducer and rechecked for slump and air content before discharge. Published data for this specific configuration is limited, but plant records from large-format floor pours show that dosage stratification in a ready-mix truck is the primary batch-to-batch variance, requiring 10–15 revolutions at mixing speed after full fiber addition to homogenize the fiber count.
Precast box culvert production with wet-cast concrete places STRUX M323 at 5.0 kg/m³ to 8.0 kg/m³ to control stripping cracks, corner spalling during demolding, and edge damage during handling. The concrete is a C35/45 or C40/50 mix with a slump of S4 under EN 12350-2, placed into steel molds on a vibratory table operating at 3,000–4,000 rpm. The fiber blend is added at the central batching plant because job-site addition into a truck mixer is not considered reliable for precast consistency; the batching sequence places fibers between the aggregate and cement fractions to avoid fiber clusters in the mix. Under EN 14889-2:2006, the product must be classified as a Class II macro-synthetic fiber, and the manufacturer’s declaration must state the effect on strength and the chloride-ion permeability behavior of the reference concrete, not only the fiber aspect ratio. Structural design of box culverts does not automatically permit a reduction in primary flexural reinforcement merely because macro fibers are present; the residual flexural strength obtained from ASTM C1399/C1399M-10(2015) is used only when the design explicitly considers post-crack moment resistance. Precast operations that demold on a 16–24 h cycle require the curing temperature profile to remain the controlling parameter; synthetic macro fibers do not accelerate early-age strength gain, and opening the side molds before the concrete reaches the specified minimum strength can produce edge breakout irrespective of fiber dosage. For drainage and sewage applications, the absence of steel corrosion permits reduced cover in splash zones only when the structural engineer confirms that the remaining reinforcement satisfies EN 1992-1-1 durability exposure classes, not as a direct function of fiber addition. Quality control records include a daily ASTM C1609/C1609M-19a beam test at L/150 deflection, a slump test before and after fiber addition, and a visual check for fiber balling at the discharge chute. When dosing exceeds 8.0 kg/m³, the mix usually requires a high-range water reducer and a longer vibration interval; the practical upper boundary in precast culverts is therefore often set by surface finish and compaction energy rather than by fiber performance.
Compliance checks for fiber-reinforced precast and floor concrete are consolidated into a single matrix because the acceptance of STRUX M323 depends on the residual-strength class and not on a nominal fiber addition rate.
| Test or specification | Standard designation | Parameter relevant to STRUX M323 |
|---|---|---|
| Synthetic macro-fiber classification | EN 14889-2:2006 | Class II polymer fiber; effect on strength declared |
| Fiber-reinforced concrete acceptance | ASTM C1116/C1116M-10a | Type III synthetic fiber-reinforced concrete |
| Flexural residual-strength test | ASTM C1609/C1609M-19a | Residual strength at L/150 |
| Average residual strength | ASTM C1399/C1399M-10(2015) | Post-crack residual strength for thin sections |
| Round-panel energy absorption | ASTM C1550-20 | Toughness for ground-support and shotcrete |
| Sprayed concrete conformity | EN 14487-1:2005 | Fiber dosage, residual flexural toughness class |
In wet-mix sprayed concrete for temporary and permanent tunnel linings, STRUX M323 is dosed at 6.0 kg/m³ to 9.0 kg/m³ to increase flexural toughness and control rebound, while the primary structural capacity remains a function of the rock mass and the shotcrete arch geometry. The mix is a C28/35 to C32/40 wet-mix concrete with a maximum aggregate size of 8 mm or 10 mm, a slump class of S4 under EN 12350-2, and a water-to-cement ratio not exceeding 0.50. The wet-mix pump and nozzle arrangement must provide a clear opening larger than 2× the nominal fiber length to prevent fiber bridging at the pump grate, the S-tube, and the nozzle tip; for a fiber length of 32 mm, the nozzle tip opening is maintained at 40 mm minimum with a corresponding pipeline diameter. Flexural toughness is evaluated on beam specimens under EN 14488-3 or on round panels under ASTM C1550-20, and the acceptance criterion is expressed as energy absorption at a defined central deflection, not as a first-crack strength. Rebound in the 15–25% range is common in overhead work; fiber addition can reduce rebound through the retention of a coherent sprayed layer, but the effect is secondary to nozzle distance, air pressure, and paste volume. Alkali-free aluminosilicate accelerators are conventionally used at the nozzle; their compatibility with the synthetic fiber blend is confirmed by early-age compressive strength tests under EN 14488-2:2006 rather than by visual observation of flash set. When a low-alkali accelerator is combined with a high-range water reducer, the dosing sequence is fixed as aggregate–cement–fiber–accelerator at the nozzle, and the pressure at the spraying machine is maintained between 6 bar and 8 bar for a 40 mm line. Published data for this specific configuration is limited, but sprayed-concrete lining crews report that fiber clumping at the pump hopper is the dominant processing bottleneck when the fiber addition exceeds 9.0 kg/m³; the hopper grate is therefore inspected at each batch to remove residual fiber accumulations before they enter the S-tube.
External hardstandings for intermodal container yards and reach stacker lanes are designed with a concrete thickness that can exceed 300 mm, and STRUX M323 is added at 4.0 kg/m³ to 7.5 kg/m³ to control the radial cracking that initiates at loaded corners and at saw-cut joints. The concrete is a C35/45 pavement mix with a maximum aggregate size of 25 mm, a minimum cement content of 350 kg/m³, and an air content compatible with the local freeze-thaw exposure class under EN 206:2013+A2:2021. The pavement design is based on subgrade modulus and axle-load spectra; the synthetic macro-fiber blend contributes post-crack residual capacity after the first crack, but it does not change the uncracked modulus of rupture used for thickness design. Round-panel testing under ASTM C1550-20 provides the energy absorption value that is used in the design model for heavily loaded joints, and the specified energy class is tied to the number of reach stacker passes rather than to a fixed fiber addition rate. Saw-cutting is carried out at a depth of 1/4 to 1/3 of slab thickness within 12–24 h after finishing, and the joint spacing is adjusted to the coefficient of subgrade friction; the fiber blend allows a modest increase in joint spacing compared with plain concrete only when the design verifies the load-transfer capacity at the joint. In freeze-thaw environments with de-icing salts, the air-void system remains the controlling variable for surface scaling resistance under ASTM C672/C672M-12; the synthetic fiber blend does not replace air entrainment and must not be used to justify a reduction in entrained air content below the exposure-class minimum. Batching is performed in a central concrete plant with a twin-shaft mixer; the fiber addition rate is controlled by a weigh hopper, because manual bag addition into a truck mixer creates dosage errors that translate into variable residual strength at the joints. Slump after fiber addition is maintained at S2 to S3 for heavy-duty pavements to prevent a paste-rich surface layer that would trap fibers during power trowelling; a low-slump mix is placed by a slipform paver or laser-guided screed depending on the bay width.
Thin architectural precast cladding panels with return faces below 100 mm are manufactured with STRUX M323 at 2.0 kg/m³ to 4.0 kg/m³ to suppress shrinkage-induced cracking around lifting anchors, fixing inserts, and return edges. The mix is a wet-cast or self-compacting C30/37 concrete with a maximum aggregate size of 10 mm and a slump flow of 650–750 mm when self-compacting concrete is used under EN 12350-8. The lower dosage range is selected for exposed aggregate or acid-etched surfaces because macro fibers become visible at the surface when the addition rate exceeds 4.0 kg/m³; this aesthetic limitation is a production constraint, not a mechanical performance ceiling. Panels are demolded after 24 h and transported to a finishing station where return edges are dressed; the synthetic fiber blend reduces the risk of corner breakage during handling but does not alter the panel’s structural connection capacity. Restrained shrinkage behavior is evaluated with ASTM C1581/C1581M-18a on the exact mix design because shrinkage-induced tension at return corners is the primary crack pathway. The mix is not designed to replace the hairpin reinforcement or edge reinforcement required by the structural engineer; the fiber is a crack-control additive within the cover zone and must be specified as such in the precast element documentation under EN 13369. Published data for this specific configuration is limited, particularly for polished surfaces, so a pre-production panel with the full mix and the selected retarder and shrinkage-reducing admixture is the only reliable method to establish acceptable surface appearance and fiber distribution.
On composite steel deck floors in multi-story buildings, STRUX M323 is added at 3.0 kg/m³ to 5.0 kg/m³ to control the early-age shrinkage cracks that form over the deck ribs and around shear studs before the concrete reaches design strength. The concrete is a C25/30 or C28/35 normal-weight or lightweight mix with a maximum aggregate size of 10 mm or 14 mm, pumped through a boom at a slump of S3 to S4 under EN 12350-2. The fiber blend is introduced at the ready-mix plant because the boom pump and deck placing sequence leave no opportunity for reliable job-site fiber dispersion. The primary structural role in the finished composite slab is carried by the steel deck and shear studs; the synthetic fibers act only in the uncracked and early crack state, and they are not considered as a replacement for welded wire mesh unless the design is based on a residual flexural strength verified by ASTM C1609/C1609M-19a. During concrete pumping, the pump line diameter must be at least 2× the fiber length, and bends in the boom are inspected after each pump stop to prevent fiber-induced blockages at the reducers. The deck is not overloaded during construction; wet concrete weight is controlled by placing in a single direction from one end of the bay. The saw-cut joint detail is usually omitted for composite decks, so the fiber addition is compared with the mesh alternative by measuring the crack width on the exposed underside after 7 days and 28 days using a crack comparator under EN 1992-1-1 serviceability requirements. When the project specification requires a two-hour fire resistance rating, the contribution of synthetic fibers to concrete spalling protection is not assumed; the fire protection strategy relies on the steel deck geometry and specified board or spray protection, not on the fiber blend.
Competitive STRUX M323 (Adfil Strux M323) - Synthetic Fiber Blend prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The designation STRUX M323, supplied as Adfil Strux M323, identifies a synthetic fiber blend intended for distribution within cementitious matrices. The material is assigned to the macro synthetic fiber class when its length, cross-section, and dosage produce post-crack residual capacity in standard beam tests. The blend is produced from polyolefin polymers; supplier-controlled composition governs melt viscosity during extrusion, fiber tenacity, surface embossing, and thermal softening behaviour. Published data for this specific configuration is limited; therefore, representative values for polyolefin macro fibers of the same class are used only where explicitly identified as non-lot-specific. The product is differentiated from single-polymer macro filaments by the blending of polymer phases, which alters fiber stiffness, pullout friction, and workability response in a way that cannot be inferred from tensile strength alone.
In structural evaluation, the contribution of a synthetic fiber blend is measured through residual flexural strength rather than tensile yield strength. The relevant test environment is a closed-loop servo-hydraulic testing frame operating under third-point loading on notched or unnotched beams. ASTM C1609/C1609M records net deflections at L/600 and L/150, with residual loads at these deflections used to derive toughness parameters. The product can be addressed in a quality plan under ASTM C1116/C1116M as Type III synthetic fiber-reinforced concrete, provided the buyer verifies the supplier’s conformance statement. The European conformity path uses EN 14889-2:2006, Annex ZA, for polymer fibers; performance is frequently tested using EN 14651:2005+A1:2007. The test method is not product-specific, but measured residual flexural tensile strengths at CMOD 0.5 mm and CMOD 3.5 mm are used to assign serviceability and ultimate residual strength classes. In a production quality plan, prism fabrication, curing, dimensional tolerance, and notch alignment must follow the method exactly because residual load is sensitive to crack propagation path and fiber bridging density across the fractured section.
| Standard designation | Test configuration | Measured parameter | Quality-plan function |
|---|---|---|---|
| ASTM C1116/C1116M | Fiber-reinforced concrete specification | Fiber type classification and dosage documentation | Material approval and mix design reference |
| ASTM C1609/C1609M | Third-point beam, closed-loop control | Residual loads at L/600 and L/150 | Post-crack performance class verification |
| ASTM C1399/C1399M | Cracked beam reloading method | Average residual strength | Comparative assessment of fiber dosage |
| EN 14889-2:2006 | Polymer fibre specification and conformity | CE marking, dimensions, and mechanical properties | Regulatory acceptance in EU projects |
| EN 14651:2005+A1:2007 | Notched beam, three-point bending | Flexural tensile strength at CMOD 0.5 mm and CMOD 3.5 mm | Residual strength class for design |
| ASTM C1550 | Centrally loaded round panel | Energy absorption from load-deflection response | Shotcrete and ground support qualification |
In sprayed concrete for slope stabilisation and tunnel ground support, the fiber is added to the aggregate stream before the nozzle. Dosage for this application is normally between 3 kg/m³ and 6 kg/m³ for synthetic macro fibers in wet-mix shotcrete, depending on the specified energy absorption class. The polymer blend influences rebound behaviour and pump stiction in ways that are not captured by single-fiber tensile strength alone. Pumping systems with 50 mm or larger delivery lines are used to reduce blockage risk at fiber concentrations above 4 kg/m³. In tunnel lining trials, documentation should include pump stroke count, air void content, accelerator type, residual strength, and panel toughness. Published data for this specific configuration is limited; a site trial with recorded batch-to-batch variance is required before production use.
Steel fibers tested under ASTM A820/A820M provide an elastic modulus of approximately 210 GPa, while polyolefin macro fibers are typically reported in the range of 3 GPa to 10 GPa. The modulus difference does not prevent post-crack control but shifts the design response: for a given residual load, the synthetic blend must rely on a larger number of fibers per unit volume and pullout friction rather than high stiffness. The polymer blend can eliminate corrosion-driven spalling at sawn joints and edges; this is the primary replacement criterion in marine or de-icing chloride environments, where steel fiber corrosion under ISO 9223 corrosivity categories C3 and C4 is a documented maintenance risk. The dosage of a synthetic blend for equivalent post-crack toughness is commonly higher by volume than steel fiber dosage; however, because the density of polyolefin is approximately 0.90–0.93 g/cm³ compared with 7.85 g/cm³ for steel, the added mass remains lower. In suspended slabs, the lower modulus of the synthetic blend must be addressed through deflection checks because the fiber does not raise the uncracked flexural stiffness of the section to the same degree as steel reinforcement.
| Fiber class | Density | Modulus | Primary reinforcement mechanism | Corrosion risk | Typical dosage range |
|---|---|---|---|---|---|
| Hooked-end steel fiber | 7.85 g/cm³ | 210 GPa | Anchorage and high tensile stiffness | Present in chloride environments | 20–40 kg/m³ |
| Polyolefin macro fiber | 0.90–0.93 g/cm³ | 3–10 GPa | Fiber-to-matrix friction and pullout resistance | None | 3–9 kg/m³ |
| Microsynthetic fiber | 0.90–0.91 g/cm³ | 3–7 GPa | Plastic shrinkage crack bridging only | None | 0.6–1.5 kg/m³ |
| STRUX M323 blend | Published data for this specific configuration is limited; class-level values should be confirmed from the supplier’s declaration of performance. | ||||
Precast tunnel segments and underground vault panels require rapid demolding cycles. In these production facilities, twin-shaft batch mixers with paddle wear monitored by clearance measurement are used to blend the fiber. The sequence of addition affects dispersion: the fiber is introduced after coarse aggregate and before free water, allowing the polyolefin surface to be wetted and distributed without adding excessive mixing energy. A mixing time of 60 s to 120 s after fiber addition is typical for this class; extended mixing beyond 180 s can increase fiber curl recovery and local balling in dry mixes. Batch records should include mixer current draw and discharge slump. A rise in current draw above the unfibered reference batch indicates interlocked clumps rather than dispersed fibers. Demolding can occur when the matrix has reached the same early strength criteria as the unfibered mix; the fiber does not function as a curing accelerator or as a substitute for proper heat curing.
Workability loss in synthetic fiber concrete is governed by fiber aspect ratio, fiber volume fraction, and surface roughness. The product is not water-absorbing in the matrix; moisture absorption of polyolefin fibers is below 0.1% by mass. Therefore, dosing changes should not be corrected by adding batch water without verifying the water-to-cement ratio against the approved mix design. Addition rates above 9 kg/m³ for this fiber class can reduce measured slump by 30 mm to 80 mm in conventional mixes, but the actual response depends on aggregate grading, paste volume, and superplasticizer type. Finishing operations require a risk assessment: exposed surface fibers can be minimized by extended trowelling immediately after the bull float, but excessive trowelling can fold fibers under the paste skin and create surface tears. High slump mixes above 220 mm may require lower fiber dosages or coarser aggregate to resist segregation. In placement operations, direct chuting into corners should be avoided because fiber-reinforced concrete can retain localized fiber concentrations that alter surface texture.
Quality-control sampling for synthetic fiber-reinforced concrete should include washout tests to determine fiber content in the fresh state. The accepted deviation is typically ± 10% of the target addition rate. For compressive strength, the fiber does not replace cement; the water-to-cement ratio and air content remain the controlling parameters. The product may be used in concrete exposed to sulfates, chlorides, and marine salts because polyolefin fibers do not corrode. However, the blend should not be used as the sole reinforcement for primary structural members unless the design explicitly uses residual strength values from EN 14651 or ASTM C1609. Conventional deformed bar reinforcement is still required for load-bearing continuity, anchorage zones, and crack control at locations of moment reversal.
The polymer blend shows a distinct thermal softening region at approximately 160 °C; this limits its use in matrices processed at elevated temperatures. In fire-rated concrete, polyolefin fibers are sometimes used at low dosages to create interconnected channels for vapour pressure relief; however, a macro synthetic structural fiber should not be assumed to provide the same spalling protection as a fine denier monofilament fiber unless tested under the relevant fire curve such as ISO 834. The blend is resistant to alkaline cement pore solution with pH above 12.5; no alkali degradation mechanism is documented for polyolefin fibers over typical service life. The product is not designed for use in hot-mix asphalt or other matrices with sustained process temperatures above 150 °C. In storage before concrete placement, fibres should remain bagged or covered; although the embedded condition isolates the polymer from solar radiation, stored fibers can suffer surface oxidation if exposed for extended periods.
Differences between STRUX M323 and finer synthetic fiber products should be measured through residual strength and workability response, not through tensile fiber strength alone. Microsynthetic fibers at dosages of 0.6 kg/m³ to 1.5 kg/m³ provide plastic shrinkage control but do not deliver post-crack flexural capacity. A macro synthetic blend provides measurable residual loads at L/150 when dosed appropriately. The exact performance of the M323 blend must be verified from the supplier’s declaration of performance under EN 14889-2:2006 and the project-specific mix design. Published data for this specific configuration is limited; therefore, laboratory trial batching remains the basis for any design substitution.