| HS Code | 993798 |
| Productname | Adfil Strux 75/32 (STRUX 75/32) - Synthetic Macro Fiber (PP/PE) |
| Material | Polypropylene/Polyethylene (PP/PE) |
| Fibertype | Synthetic macro fiber |
| Length | 32 mm |
| Aspectratio | 75 |
| Equivalentdiameter | 0.43 mm |
| Tensilestrength | 620 MPa |
| Elasticmodulus | 9.5 GPa |
| Density | 0.91 g/cm3 |
| Meltingpoint | 170 °C |
| Ignitionpoint | > 400 °C |
| Alkaliresistance | High |
| Acidresistance | High |
| Waterabsorption | Nil |
| Typicaldosage | 3-9 kg/m3 |
| Fibersperkg | Approximately 240,000 |
| Thermalconductivity | Low |
| Electricalconductivity | Low |
| Creep | Low |
As an accredited Adfil Strux 75/32 (STRUX 75/32) - Synthetic Macro Fiber (PP/PE) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Adfil Strux 75/32 synthetic macro fiber is packaged in 20 kg moisture-resistant bags for safe storage and transport. |
| Container Loading (20′ FCL) | 20′ FCL: 20 pallets, 40 x 10 kg bags per pallet, 800 bags, 8,000 kg net, shrink-wrapped. |
| Shipping | Adfil Strux 75/32 (STRUX 75/32) synthetic macro fibers (PP/PE) ship as non-hazardous, non-regulated cargo. Supplied in bags or cartons, palletized and shrink-wrapped. Transport in dry, covered vehicles. Protect from moisture, UV, and excessive heat. Store indoors, keep sealed; no dangerous goods documentation required. |
| Storage | Store Adfil Strux 75/32 (STRUX 75/32) synthetic macro fiber in a cool, dry, well-ventilated area, in original sealed packaging. Protect from moisture, direct sunlight, and extreme temperatures. Keep away from ignition sources, oxidizers, and contaminants. Stack pallets safely; avoid damaging bags. Maintain good housekeeping. Under these conditions, shelf life is generally indefinite. Store at ambient temperature. |
| Shelf Life | Stable for at least 24 months when stored dry, unopened, in original packaging, away from direct sunlight and extreme temperatures. |
For jointless ground-supported slabs, Adfil STRUX 75/32 is added at a typical rate of 4.0 kg/m³ within a working range of 3.5–5.0 kg/m³; this corresponds to approximately 0.43% by volume at a nominal PP/PE blend density of 0.92 g/cm³. The specification sits under EN 14889-2:2006 Annex ZA for CE marking and ASTM C1116/C1116M-23 Type III synthetic fiber-reinforced concrete, while slab design and joint spacing follow Concrete Society TR34 4th edition and ACI 302.1R-15. Residual flexural strength is measured on 150 mm × 150 mm × 600 mm beams according to EN 14651:2005+A1:2007 or ASTM C1609/C1609M-19a, with acceptance values taken at CMOD 0.5 mm and 3.5 mm for fR1k and fR3k respectively. Published data for this specific configuration is limited outside the manufacturer’s technical file, so trial mixes are required. Batching in a 3.0 m³ twin-shaft compulsory mixer requires the fiber to be introduced with coarse aggregate in a dry premix phase of 15–20 s before cement and water are added; total wet mixing after fiber addition is limited to 60–90 s. Single-charge dumping into the mixer head can create fiber clumps, whereas continuous screw conveyor or perforated belt dosing improves distribution. Fresh concrete is specified at slump 120±20 mm with polycarboxylate ether superplasticizer adjusted to 0.8–1.2% by weight of cement because macro fiber reduces slump by 20–40 mm at constant water-to-cement ratio. Placement uses a laser screed and edge formwork, followed by immersion vibration at construction joints and isolated details. Bleed water must have evaporated before low-angle power float passes begin; more than six steel trowel passes per area can raise surface fuzz from exposed polymer fibers. Saw-cut contraction joints are spaced according to TR34, not eliminated solely by fiber use. Terminal product types include high-bay warehouse slabs, distribution center floors, racking aisle slabs, and logistics hub ground slabs.
In precast tunnel segment production, the shift from conventional welded wire mesh to STRUX 75/32 at 5.5–7.0 kg/m³ alters the dosage sequence inside planetary counter-current mixers; the addition rate is selected through beam tests to EN 14651:2005+A1:2007 with acceptance values fixed by the segment design engineer for the relevant ground class. Fiber compliance is documented under EN 14889-2:2006 and ASTM C1116/C1116M-23. A typical segment concrete uses water-to-binder ratio 0.32–0.36, silica fume at 6–8% by weight of binder, and high-range water reducer to maintain mold slump of 80–120 mm. The batching order in a 1.5–2.0 m³ planetary counter-current mixer is coarse aggregate and fiber dry-mixed for 15–20 s, followed by cement and silica fume, then the water-admixture solution; fibers added after water float or clump at the mixer wall and in the discharge gate. Casting into steel segment molds uses external high-frequency vibrators and a cycle of 8–12 min per segment to reach full compaction without lifting fibers toward the rubber gasket recesses. Steam curing is applied at 55–65°C for 8–10 h before demolding; reduced edge spalling during form stripping is reported above 5.0 kg/m³ but requires trial confirmation. Published long-term creep data for this specific configuration is limited, so type testing and trial mixes are mandatory. Terminal product types include reinforced concrete TBM tunnel lining segments, segmental shaft collars, and precast junction segments.
Wet-mix sprayed concrete placed by a swing-valve concrete pump through a 40 mm delivery line and air-assisted nozzle uses STRUX 75/32 at 4.5–7.0 kg/m³; below 4.5 kg/m³ the flexural toughness class is usually insufficient for the F2/F3 requirements of EN 14488-3:2006, while above 7.0 kg/m³ pump pressure increases and rebound can exceed 25% in coarse tunnel shotcrete. Compliance is governed by EN 14487-1:2005, ASTM C1436-13, and ACI 506.1R-17. The transit mixer maintains 6–8 rpm agitation at the pump inlet; concrete slump is held at 180–220 mm to prevent hopper segregation and fiber filter-cake formation. Alkali-free accelerator is injected at 4–8% by weight of binder at the nozzle, with compressed air at 0.5–0.7 MPa and 5–8 m³/min. Layer builds of 30–50 mm per pass are used on vertical rock faces to control sloughing and rebound, and nozzle distance from the substrate is maintained at 0.5–1.5 m perpendicular to the sprayed surface. Fiber balling at the pump inlet occurs when slump drops below 140 mm or when fibers are added without sufficient aggregate premixing in the ready-mix plant. Terminus products include primary rock support linings in drill-and-blast tunnels, permanent slope stabilization facings, and repair linings in hydraulic channels.
When breakwater armour units are cast with STRUX 75/32, the mix design must account for extended form stripping and saltwater curing; the fiber addition is controlled at 4.0–6.0 kg/m³ because higher weight fractions make open-top truck chute addition visible at form edges and in cover zones. The concrete is specified under EN 206:2013+A2:2021 for exposure classes XS2 and XC4, with fiber compliance to EN 14889-2:2006 and ASTM C1116/C1116M-23; marine structures are additionally detailed to BS 6349-1:2000 or EN 1992-1-1 for cover and crack control. A central twin-shaft mixer is used for 5–15 m³ placements, with fiber injected into the aggregate stream at the weigh hopper rather than added to the truck chute. The water-to-binder ratio is capped at 0.40 and minimum cementitious content at 380 kg/m³ for chloride resistance; slump at discharge is 100±20 mm. Internal immersion vibrators with 50–60 mm heads compact the mass at 0.3 m grid spacing. Demoulding is delayed by 12–24 h relative to plain concrete to limit edge spalling, and trial pours are used to validate stripping at dosages above 6.0 kg/m³. Curing with potable water continues for 7 days where tidal exposure or wetting–drying cycles are expected. Synthetic macro fiber does not lower chloride diffusion coefficient; cover to embedded steel is unchanged. Terminal product types include tetrapod and accropode armour units, breakwater capping beams, and quay wall closure blocks.
Wet-cast box culvert and manhole base production with external form vibrators and a water-to-cement ratio of 0.38–0.42 is a valid downstream process for STRUX 75/32 at 3.0–5.0 kg/m³. This addition range is not transferable to dry-cast pipe production: the 4–6% moisture content of zero-slump concrete cannot open and suspend macro fibers, and packerhead or vibro-compaction methods do not generate sufficient matrix flow for fiber distribution. The wet-cast process uses a 1.0–2.0 m³ planetary or twin-shaft mixer; fiber is introduced after coarse aggregate and before water, with a wet mixing time of 60–90 s. Slump is maintained at 80±20 mm to avoid excessive movement under external vibrator frequencies of 3,000–5,000 vibrations per minute, because high-frequency vibration can drive lightweight polymer fibers toward the form face and reduce surface quality at headwalls and joint recesses. Standards applied to finished elements include EN 1916:2002 for precast concrete pipes, ASTM C1433/C1433M-20 for precast box culverts, and EN 14889-2:2006 for the fiber system. Forms are stripped when cube compressive strength reaches 10–12 MPa, typically after 18–24 h. Three-edge bearing tests or monotonic load tests on finished culverts are used to confirm performance because fiber distribution influences crack width at proof load. Terminal product types include stormwater box culverts, headwalls, manhole bases, and junction chambers.
Agriculturally exposed slabs in silage aprons and manure transfer lanes require a distinct fiber addition sequence because ammonia vapour and low relative humidity during summer casting increase plastic shrinkage cracking. STRUX 75/32 is used at 4.0–5.0 kg/m³ and specified through EN 14889-2:2006 with concrete conforming to EN 206:2013+A2:2021 and ASTM C1116/C1116M-23. The concrete uses a CEM III/A or CEM III/B binder at a minimum 360 kg/m³, a water-to-binder ratio not exceeding 0.45, and a point-of-discharge slump of 130±20 mm. Fiber is batch-injected at the plant, not added to the truck chute, because open chute addition in agricultural pours creates clumps at edge forms and channel mouths. Placement is made by 50 mm concrete pump or skip, and finishing is limited to bull float and wooden float passes; power trowelling is avoided because steel blades pull polymer fibers to the surface and create fuzz. The slab is cured for a minimum of 7 days under membrane or wet burlap. Fiber reinforcement does not replace an impermeable barrier or chemical-resistant coating: silage leachate pH can fall below 4.0, and exposure class XA3 under EN 206:2013+A2:2021 requires an additional protective layer in direct contact zones. Terminal product types include silage aprons, manure transfer lanes, and slatted floor support slabs.
Competitive Adfil Strux 75/32 (STRUX 75/32) - Synthetic Macro Fiber (PP/PE) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Adfil Strux 75/32 (STRUX 75/32) is a synthetic macro fiber manufactured from a polypropylene/polyethylene blend. It is supplied as a discrete secondary reinforcement for integration into fresh concrete and wet-mix sprayed concrete. The fiber is intended to resist crack opening after first crack and to improve post-crack residual load capacity in slabs, pavements, precast elements, and sprayed linings. Under EN 14889-2:2006, polymer fibres for concrete are divided into Class I microfibres with an equivalent diameter below 0.3 mm and Class II macrofibres with an equivalent diameter of 0.3 mm or greater; STRUX 75/32 is classified as Class II. In North American practice, the fibre is considered a Type III synthetic fibre-reinforced concrete component under ASTM C1116/C1116M. The designation 75/32 identifies a nominal length of 75 mm and a grade indicator 32. The manufacturer’s technical data sheet is the controlling document for tensile strength, elastic modulus, cross-sectional geometry, and permissible dosage range. Published data for the exact properties of this grade are limited; the technical description below therefore refers to the product class and to established test methods governing specification, batching, and performance verification.
The European harmonized standard EN 14889-2:2006 establishes requirements for polymer fibres for concrete. Class II macrofibres are defined by an equivalent diameter of at least 0.3 mm; Class I microfibres fall below this threshold. The distinction controls whether a fibre is specified for plastic shrinkage suppression only or for post-crack resistance in semi-structural applications. STRUX 75/32, because of its length and diameter class, is specified where a macrofibre is required rather than a microfibre. Under ASTM C1116/C1116M, synthetic fibre-reinforced concrete is classified as Type III. The standard describes requirements for fibre dimensions, dosage, and mixing. For CE marking, factory production control and initial type testing must follow EN 14889-2:2006. Table 1 lists the compliance matrix and test methods.
| Property or requirement | Standard or test method | Class or criterion |
|---|---|---|
| Fibre classification | EN 14889-2:2006 | Class II macrofibre |
| Equivalent diameter threshold | EN 14889-2:2006 | ≥ 0.3 mm |
| Concrete classification | ASTM C1116/C1116M | Type III synthetic fibre-reinforced concrete |
| Flexural performance | ASTM C1609/C1609M | Residual strength at net deflections L/600 and L/150 |
| Shotcrete energy absorption | ASTM C1550/C1550M | Energy absorption at 40 mm central deflection |
| Sprayed concrete requirements | EN 14487-1, EN 14488-5 | Wet-mix macrofibre reinforcement |
| CE marking conformity | EN 14889-2:2006 Annex ZA | Factory production control and initial type testing |
The macrofibre classification does not imply a fixed residual strength class under EN 14889-2:2006; the manufacturer declares the effect on concrete in terms of residual flexural strength class. Because published data for the 32 grade are limited, a trial mix is required to establish the actual class. The PP/PE matrix is not electrochemically active, so the product has no corrosion mechanism in chloride-containing concrete. This property is one of the main differences from steel fibre and welded wire mesh in environments where chlorides penetrate to the reinforcement.
The polypropylene/polyethylene matrix places the fibre density between 0.90 g/cm³ and 0.94 g/cm³, compared with approximately 7.85 g/cm³ for low-carbon steel. At equal volume fraction, therefore, STRUX 75/32 contributes approximately 12 % of the mass of steel fibre. Commercial polyolefin macrofibres of comparable length are typically specified with tensile strength between 400 MPa and 650 MPa and elastic modulus between 3 GPa and 10 GPa. Steel fibre is typically specified with tensile strength of 1,000 MPa to 2,200 MPa and elastic modulus near 200 GPa. This stiffness difference means that post-crack capacity in concrete containing PP/PE macrofibres is developed through fibre pullout and crack-bridging rather than through direct elastic modulus equivalence to steel. Direct mass-for-mass substitution of steel fibre by STRUX 75/32 is therefore not valid. The dosage must be re-established by flexural performance testing or project-specific design calculations.
The PP/PE backbone is stable in the alkaline pore solution of portland cement concrete, where pH normally exceeds 12.5. It is not subject to chloride-induced corrosion. The polymer is not chemically resistant to strong oxidizing acids or aromatic hydrocarbon solvents, and prolonged storage should avoid direct sunlight and temperatures above the manufacturer’s stated limit to prevent fibre distortion. These limitations are usually not controlling in building and civil engineering concrete; in chemical plant floors exposed to organic solvents, fibre supplier guidance should be obtained.
Flexural performance is evaluated by four-point bending in accordance with ASTM C1609/C1609M. The test reports first-peak flexural strength and residual strengths at net deflections of L/600 and L/150. For a span of 450 mm, these deflections correspond to 0.75 mm and 3.0 mm. The ratio of residual strength to first-peak strength, often designated R3/R1, indicates whether the section is deflection-softening or deflection-hardening. At macrofibre dosages below 3.0 kg/m³, the fibre primarily controls crack width and may not produce significant post-crack flexural capacity in suspended slabs. Dosages between 4.0 kg/m³ and 7.0 kg/m³ are commonly evaluated for ground-supported slabs and pile-supported floors. The required dosage for STRUX 75/32 must be determined from load-deflection curves supplied by the manufacturer and verified by trial mixing and ASTM C1609/C1609M testing.
Round panel energy absorption testing under ASTM C1550/C1550M is used for sprayed concrete and some slab applications. The panel is 800 mm in diameter and 75 mm thick; energy absorption is measured up to 40 mm central deflection. This test captures fibre-matrix interaction over large crack rotations and is sensitive to fibre length, aspect ratio, and dosage. Published energy absorption values for the 32 grade are limited; therefore, prequalification by an independent laboratory or notifying body is necessary for performance specifications.
Mixing sequence controls fibre dispersion and early-age workability. In a twin-shaft compulsory mixer with rated batch capacity of 3.0 m³, STRUX 75/32 is typically introduced after the aggregates and cementitious materials have been blended with part of the mixing water. The fibre should be discharged as a free-flowing stream over the aggregate surface rather than into the water alone or into the fines first; this reduces the tendency to form fibre balls. After fibre addition, mixing is extended for 30 s to 60 s, and the slump is checked according to ASTM C143/C143M or EN 12350-2. If the slump is below specification, water adjustment should be made only within the mix design limits and with the approval of the responsible engineer, because water added after fibre inclusion changes the water-cementitious materials ratio and may reduce compressive strength. In truck mixers, high-speed mixing should be limited to the manufacturer’s recommended interval to avoid excessive air entrainment and workability loss.
Batch-to-batch uniformity is verified by washing out a known fresh concrete sample and weighing and counting the fibres. The supplier’s reported fibre count per kilogram can be used for this on-site quality assurance check. The fresh concrete should be sampled in accordance with ASTM C172/C172M. If the recovered fibre count differs from the expected count by more than the project tolerance, the batching sequence or mixing time should be corrected. Localised fibre clumps visible in hardened concrete saw-cut sections indicate insufficient dispersion and can reduce the intended post-crack performance.
Steel fibres and welded wire mesh provide post-crack strength through high elastic modulus and ductile steel deformation. Synthetic macrofibres provide post-crack strength through a larger number of lower-stiffness fibres bridging the crack. In ground-supported slabs, steel fibre dosages of 15 kg/m³ to 40 kg/m³ are common, whereas PP/PE macrofibres are specified at 3 kg/m³ to 9 kg/m³ because of lower density and different tensile properties. The lower mass dosage corresponds to a much higher fibre count per unit volume. For a 75 mm macrofibre of equivalent diameter near 0.8 mm, the number of fibres per kilogram may exceed 20,000; comparable steel fibre counts are lower at equal mass dosage. This high fibre count improves crack spacing control but does not automatically replicate steel fibre toughness. Design guides such as Concrete Society TR34 and ACI 544.4R provide methods for using fibre-reinforced concrete in slabs-on-ground; the residual strength input must come from actual ASTM C1609/C1609M test results.
When steel corrosion is the governing performance requirement, the PP/PE macrofibre removes the need for galvanizing or stainless steel fibre. It also reduces stray current and electromagnetic effects, which is relevant in floors supporting automated guided vehicles, MRI equipment zones, and induction heating machinery. The lower elastic modulus of the synthetic macrofibre, however, means that long-term creep under sustained loading may be greater than in steel fibre-reinforced concrete. Published creep data for this specific grade are limited; if sustained loads are high, a project-specific creep assessment based on fibre pullout creep and concrete matrix creep should be performed.
| Parameter | Adfil Strux 75/32 macrofibre | Steel macrofibre | PP microfibre |
|---|---|---|---|
| Matrix | PP/PE blend | Low-carbon steel | PP |
| Density | 0.90–0.94 g/cm³ | 7.85 g/cm³ | 0.90–0.94 g/cm³ |
| Nominal length | 75 mm | Typically 35–60 mm | Typically 6–19 mm |
| Primary test method | ASTM C1609/C1609M, ASTM C1550/C1550M | ASTM C1609/C1609M, EN 14889-1:2006 | ASTM C1579/C1579M for plastic shrinkage |
| Post-crack residual capacity | Moderate, dosage-dependent | High | Negligible |
| Corrosion risk in concrete | None | Present if cracking allows chloride ingress | None |
Wet-mix sprayed concrete containing STRUX 75/32 is batched before transport; the fibre should not be introduced at the gun or nozzle. The delivery hose inner diameter should be not less than 50 mm; the sprayed layer thickness should be at least 2.5 times the fibre length, or approximately 190 mm for this 75 mm product, to limit rebound and avoid unfavourable fibre orientation. Rebound of synthetic macrofibres can be lower than that of steel fibre because of the lower density and elongated shape, but rebound losses still require a trial spray evaluation. The material is qualified for tunnel linings by ASTM C1550/C1550M round panel testing or by European sprayed concrete standards EN 14487-1 and EN 14488-5. For rock support, the fibre-reinforced shotcrete is specified by energy absorption class, not solely by compressive strength. Published data for STRUX 75/32 in this application are limited; the mix design must be validated with the specific cement, accelerator, and water-reducing admixture combination proposed for the project.
Admixture compatibility should be verified through trial mixes. Polycarboxylate-based high-range water reducers are commonly used with macrofibre concrete; the compatibility risk is not with the polymer fibre itself but with the early stiffening effects of some accelerators and the fibre’s influence on slump retention. In sprayed concrete, alkali-free accelerators are generally preferred over alkaline aluminates when macrofibres are present, because rapid stiffening and high early pH can increase rebound and reduce fibre encapsulation. Trial mixes should be prepared with the exact cement type, supplementary cementitious materials, accelerator, and fibre dosage, and tested at the specified slump and pump discharge temperature.
Thermal exposure alters the modulus of polyolefin fibres. The coefficient of thermal expansion of PP/PE is higher than that of surrounding concrete; at normal ambient temperature ranges this mismatch is accommodated by the fibre-matrix interface. At elevated temperatures approaching the softening point of polypropylene, the fibre modulus and load-transfer capacity decrease. In fire-resistant concrete design, PP microfibres are commonly used to reduce explosive spalling by creating water-vapour release channels, but STRUX 75/32 is a macrofibre and should not be used as the sole fire-spalling protection. Fire resistance should be specified by EN 1992-1-2 or ACI 216.1 without relying on the macrofibre for structural load capacity. Published data for the thermal softening behaviour of the 32 grade are limited.
The finished surface of a slab containing synthetic macrofibres should be power-troweled only after the initial bleed water has disappeared and the fibres have been covered by paste. Early troweling can drag fibres to the surface and create protruding surface fibres. If surface aesthetics are specified, light blast cleaning or diamond grinding may be required. The product does not rust, so surface staining from fibre corrosion is not a concern. For abrasion resistance, the concrete matrix should be specified according to ASTM C779/C779M or EN 13813 as applicable; the macrofibre does not replace hardeners or dry-shake surface treatments where those are separately specified.