| HS Code | 338668 |
| Product Name | Adfil Strux 85/50 (STRUX 85/50) - Synthetic Macro Fiber (PP/PE) |
| Material | Polypropylene/polyethylene blend |
| Fiber Type | Synthetic macro fiber |
| Fiber Length | 50 mm |
| Fiber Diameter | 0.85 mm |
| Aspect Ratio | 59 |
| Tensile Strength | 600 MPa |
| Elastic Modulus | 9.5 GPa |
| Density | 0.91 g/cm³ |
| Melting Point | 160 °C |
| Ignition Point | >400 °C |
| Alkali Resistance | High |
| Water Absorption | Negligible |
| Recommended Dosage | 4-6 kg/m³ |
| Packaging | 10 kg bags |
| Standard Compliance | EN 14889-2 |
As an accredited Adfil Strux 85/50 (STRUX 85/50) - Synthetic Macro Fiber (PP/PE) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Adfil Strux 85/50 synthetic macro fiber is packaged in 10 kg moisture-resistant bags, typically 48 bags per pallet (480 kg total). |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized Adfil Strux 85/50 synthetic macro fiber (PP/PE) bags, shrink-wrapped and secured; non-hazardous for export. |
| Shipping | Adfil Strux 85/50 (STRUX 85/50) synthetic macro fiber (PP/PE) is non-hazardous and not classified as dangerous goods for transport. It is supplied in moisture-resistant bags or cartons, palletized and shrink-wrapped. Store dry, away from direct sunlight, moisture, and ignition sources. Use standard handling and PPE. No special transport labeling required. |
| Storage | Store Adfil Strux 85/50 synthetic macro fibers in a cool, dry, well-ventilated area, away from direct sunlight, moisture, heat, and ignition sources. Keep in original, closed packaging, palletized off the ground. Avoid prolonged UV exposure and crushing. Maintain good housekeeping and stock rotation. No special ventilation is normally required. Keep away from incompatible chemicals and dust-generating operations. |
| Shelf Life | Indefinite shelf life if stored dry, unopened, in original packaging, protected from direct sunlight and moisture; store under normal conditions. |
Adfil Strux 85/50 is incorporated into ready-mixed concrete for jointless ground-supported slabs in logistics hubs, automated storage and retrieval warehouses, and container terminals. The PP/PE macro-fibre is dosed at 1.8 kg/m³ to 4.5 kg/m³; the lower bound is applied to slabs with saw-cut contraction joints, while the upper bound is specified where joint spacing exceeds 50 m and early-age shrinkage cracking is to be controlled without welded-wire mesh. In a twin-shaft compulsory mixer with a rated batch volume of 3 m³, the fibres are introduced after aggregate-cement homogenisation and before admixture dosing stabilises the water-cement ratio at 0.42 to 0.48. On placement, a laser-guided screed strikes off the concrete at a slump of 120 mm to 160 mm, and fibre clumping in the screed auger is managed by keeping the discharge gate clear and rejecting partially opened bags at the batching plant. The hardened slab is evaluated under ASTM C1609/C1609M using 150 mm × 150 mm × 500 mm third-point beams; post-crack residual strengths for fibre contents in this range commonly fall between 1.2 MPa and 2.1 MPa at a net deflection of L/400. Jointless panel design should specify a minimum average residual strength ratio of 25 % to 35 % under EN 14889-2:2006, because lower values have been associated with uncontrolled mid-panel crack propagation beneath racking outrigger loads. Batching error greater than ±0.2 kg/m³ is detectable as increased slump loss after 20 minutes, and fibre count per cubic metre should be checked by a wash-out sample on the first 3 loads each day to control batch-to-batch variance. The terminal concrete element is power-trowelled after bleed-water disappearance, and the absence of ferrous fibre staining is relevant for receiving yards where surface appearance is an acceptance criterion under the project quality plan.
| Application sector | Indicative dosage range | Governing test | Field verification |
|---|---|---|---|
| Jointless industrial slab | 1.8 kg/m³–4.5 kg/m³ | ASTM C1609/C1609M, EN 14889-2:2006 | Wash-out count, residual strength at L/400 |
| Wet-mix shotcrete | 4.0 kg/m³–7.0 kg/m³ | ASTM C1550-20, EFNARC | Panel energy absorption at 40 mm central deflection; rebound loss |
| Precast thin-wall units | 2.0 kg/m³–3.5 kg/m³ | EN 14889-2:2006, ASTM C1116/C1116M | Demoulding strength; edge spall inspection |
| Pavement whitetopping | 2.5 kg/m³–4.5 kg/m³ | ASTM C1550-20, EN 13036-4 | Joint efficiency; crack-width mapping |
In sprayed concrete for rock support, Adfil Strux 85/50 is charged into the wet-mix hopper at 4.0 kg/m³ to 7.0 kg/m³ before the alkali-free accelerator is dosed at the nozzle. The critical processing variable is fibre orientation after pneumatic projection: unlike slab concrete, where fibres align predominantly in the horizontal placement plane, shotcrete fibres rotate as they travel from the nozzle to the substrate, producing a near-random in-plane distribution with reduced through-thickness alignment. Panel testing under ASTM C1550-20 uses a 75 mm thick round panel of 800 mm diameter and is preferred because it captures biaxial bending better than a single beam specimen. Energy absorption at 40 mm central deflection for synthetic macro-fibre shotcrete at the upper dosage range is often reported between 280 J and 420 J; however, published data for the specific Strux 85/50 wet-mix configuration is limited, and pre-construction qualification panels should be sprayed on site. The wet-mix process requires a maximum aggregate size of 8 mm to 10 mm; larger limestone or granite particles increase fibre rebound and reduce the effective in-situ fibre content. Rebound losses measured at the receiver are commonly 10 % to 25 % of total shotcrete mass, and the low-density PP/PE fibre rebounds preferentially because of its higher drag-to-mass ratio; the in-situ fibre content may therefore be 0.5 kg/m³ to 1.5 kg/m³ lower than batched unless the nozzle is maintained at 85° to 90° to the substrate. Alkali-free aluminium sulfate accelerators typically produce initial setting times of 2 min to 5 min at 20 °C; the polyolefin fibre does not undergo alkaline hydrolysis in the short term, but the high-pH pore solution above 13.0 is a long-term condition that must be addressed through mix design and curing. The finished application is a temporary or permanent rock-support lining of 80 mm to 120 mm thickness in road tunnels or mine access declines, with the fibre providing post-crack toughness that reduces the required welded-wire mesh layer count by one to two layers.
Architectural cladding panels, acoustic barrier shells, and small-diameter drainage channels are produced with an equivalent concrete cover of 10 mm to 15 mm without macroscale carbon-steel mesh when Adfil Strux 85/50 is added at 2.0 kg/m³ to 3.5 kg/m³. The precast mix is usually a self-compacting concrete with a maximum aggregate size of 6 mm to 8 mm, and the fibre is blended in a high-shear planetary mixer after the polycarboxylate superplasticiser has dispersed the cement paste onto the fine aggregates. Demoulding strength of 18 MPa to 22 MPa is reached in 16 h to 24 h under controlled curing at 35 °C; the fibre-reinforced units resist edge damage during stripping because the macro-fibre bridges the narrow lip sections that would otherwise spall under ejection force. Compliance is assessed through EN 14889-2:2006 performance criteria for polymer macro-fibres, with the CE declaration listing fibre geometry, tensile strength, alkali resistance, and the effect on concrete consistency. The terminal units include motorway acoustic barriers with a panel thickness of 100 mm and precast headwalls where conventional steel reinforcement would create galvanic corrosion risk in sulphate-bearing groundwater. Because the elastic modulus of PP/PE macro-fibre is lower than that of steel, the fibre is not a substitute for primary bending reinforcement in load-bearing precast beams or columns; in thin flat elements, however, the fibre’s post-crack flexural behaviour provides damage tolerance for handling and service microcracking. Published data for the specific structural contribution in slender precast sections is limited, so full-scale flexural testing under ASTM C1609/C1609M or EN 14651 should be performed when the fibre contribution is assumed in the design model.
On bus rapid-transit lanes and industrial road intersections where a 100 mm to 150 mm bonded concrete overlay is placed over an existing asphalt or concrete substrate, Strux 85/50 is incorporated at 2.5 kg/m³ to 4.5 kg/m³ to control plastic shrinkage and provide post-crack load transfer in the overlay. The slipform paver or vibratory screed processes the fibre-reinforced concrete at a spread rate of 1.5 m/min to 2.5 m/min, and the fibre must be batched consistently to prevent clumping in the paver’s auger chamber. Field verification for whitetopping usually includes joint efficiency testing and crack-width mapping rather than beam residual strength alone; however, the mix is pre-qualified by ASTM C1550-20 round panel tests to confirm that fibre addition raises the energy absorption at 40 mm central deflection from a plain concrete baseline of 5 J to 10 J to a value above 150 J. The terminal pavement product is a jointed or semi-continuous overlay with saw-cut contraction joints spaced at 2.5 m to 3.0 m, and the synthetic macro-fibre reduces the amount of conventional transverse steel or small-diameter dowel baskets at joint locations. In comparison with steel fibres, the PP/PE product does not produce surface corrosion spots after winter de-icing salt exposure, which is a terminal-service requirement for bus lanes where surface skid resistance is inspected under EN 13036-4. Published data for Strux 85/50 in bonded whitetopping over asphalt is limited; therefore, a test section of at least 200 m² should be placed before full-scale paving.
Where high-frequency welding cells, induction charging stations along automated guided vehicle routes, and magnetic resonance imaging halls generate electromagnetic interference or eddy-current constraints, the floor plate mix excludes steel fibres entirely and uses Adfil Strux 85/50 at 3.0 kg/m³ to 5.0 kg/m³. The PP/PE macro-fibre has a volume resistivity above 10⁶ Ω·cm, whereas steel-fibre-reinforced concrete can behave as a partial conductor under damp conditions and attenuate radio-frequency signals. Placement of the fibre-reinforced slab under an overhead travelling crane with a payload of 20 t uses a laser-guided screed and ride-on power trowel; the fresh concrete slump is held at 140 mm to 180 mm to avoid fibre balling in the screed auger. Because the polyolefin fibre does not generate ferrous dust during power trowelling, the finished surface can be sealed with a lithium-silicate densifier after 7 days without the efflorescence associated with steel-fibre oxidation. The design limit is the lower post-crack flexural modulus of polymer fibres: for a suspended floor plate, the fibre does not provide continuous structural tension capacity across negative moment regions, and supplementary reinforcing bars or post-tensioning remain mandatory. The relevant fibre specification remains EN 14889-2:2006, but the project specification should reference ASTM C1609/C1609M third-point beam testing and tabulate the residual flexural strength at L/400 and L/600 deflection points.
| Parameter | Test method / standard | Acceptance criterion |
|---|---|---|
| Fibre alkali resistance | EN 14889-2:2006 | No significant visual degradation after 28 days in pH 12–13 solution |
| Effect on fresh concrete consistency | EN 14889-2:2006 | Slump reduction ≤ 40 mm compared with reference mix |
| Residual flexural strength | ASTM C1609/C1609M | Project-set residual strength ratio; often 25 %–35 % for slab applications |
| Round panel energy absorption | ASTM C1550-20 | Project-specific; value above 150 J at 40 mm deflection commonly specified |
| Freeze-thaw resistance | ASTM C666/C666M | Durability factor ≥ 80 % after 300 cycles for exposed applications |
| Bond strength of overlay/screed | EN 1542 | Pull-off strength ≥ 1.0 MPa for bonded systems |
Levelling screeds in logistics mezzanines, bonded repair overlays on bridge access ramps, and unbonded screeds in refrigerated displays are mixed with Strux 85/50 at 1.0 kg/m³ to 2.5 kg/m³, a lower range than structural slabs because the screed’s primary function is delamination resistance and crack-width control rather than flexural moment transfer. The dry-mix or semi-dry screed is processed through a forced-action paddle mixer, and the fibre is introduced at the beginning of the cycle to allow mechanical dispersion before water is added to the cementitious binder. Because published data for this specific configuration is limited, cyclic freeze-thaw verification under ASTM C666/C666M is required before the screed is exposed to continuous -25 °C service. The terminal construction is a 40 mm to 70 mm thick bonded or unbonded screed that provides a crack-free base for high-density racking legs and forklift transit in cold-chain facilities. Bond strength to the substrate is measured using pull-off tests according to EN 1542, and a minimum bond strength of 1.0 MPa is commonly required; the addition of macro-fibre does not supersede the need for mechanical preparation of the existing concrete surface by captive shot-blasting. The fibre’s specific gravity of 0.91 means that the product is distributed through the full screed thickness rather than settling to the bottom, but the mixing time must be extended by 15 s to 30 s per batch compared with an equivalent unreinforced mix.
For buried stormwater detention chambers and cast-in-place culvert surrounds subject to seasonal wet-dry cycles and de-icing salt runoff, Strux 85/50 is batched at 3.0 kg/m³ to 5.0 kg/m³ to replace light crack-control mesh in zones where conventional reinforcement would require additional concrete cover. The concrete is delivered with a maximum aggregate size of 10 mm to 14 mm and consolidated with high-frequency immersion vibrators; the fibre does not interfere with the vibration path, but over-vibration beyond 15 s per insertion can orient the fibres into horizontal planes and reduce vertical face stability. Durability is governed by EN 206 and ASTM C1433/C1433M for precast box culverts, and the macro-fibre assists in controlling corner and edge cracking during compaction and backfilling. The terminal structures are typically buried stormwater detention chambers and overflow channels where conventional reinforcement would require additional cover of 40 mm to 50 mm against chloride ingress; the synthetic fibre does not reduce code-required cover, but it provides crack-control redundancy without corrosion staining. Published data for Strux 85/50 in buried hydraulic structures is limited; therefore, permeability testing under EN 12390-8 and chloride diffusion profiling under ASTM C1556 should be included in the qualification mix.
Competitive Adfil Strux 85/50 (STRUX 85/50) - Synthetic Macro Fiber (PP/PE) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Adfil STRUX 85/50 is a macro synthetic fibre produced from a polypropylene/polyethylene (PP/PE) copolymer blend and intended for secondary reinforcement of concrete and cementitious matrices. The designation 85/50 identifies a nominal aspect ratio of 85 and a nominal cut length of 50 mm. The fibre is classified as a Type III synthetic fibre under ASTM C1116/C1116M and as a Class II macro polymer fibre under EN 14889-2:2006. Supplier technical data list an equivalent diameter of 0.59 mm, a specific gravity of 0.91, a tensile strength of 620 MPa, an elastic modulus of 9.5 GPa, and a melting point of 160 °C. Because the specific gravity of the polymer is near that of water, the fibres remain distributed through the concrete matrix during vibration without the sedimentation commonly observed with steel fibres.
The product is used in slabs-on-ground, external hardstandings, pavements, precast elements, tunnel linings, composite metal deck overburdens, and wet-mix sprayed concrete. In these applications, the fibre is intended to reduce plastic settlement cracking, control crack width after hardening, increase impact resistance as measured by ACI 544.2R repeated drop-weight testing, and provide post-crack residual capacity under ASTM C1609/C1609M or EN 14651:2005+A1:2007. It is not a direct replacement for primary reinforcing steel in structural bending applications unless a design engineer has used fibre-specific post-crack parameters in the structural model.
The inclusion of polyethylene in the copolymer reduces low-temperature brittleness and increases fibre flexibility compared with homopolymer polypropylene macro fibres. The fibre is not hygroscopic; moisture absorption is listed as 0% by supplier data, so high-humidity storage does not require pre-drying before batching.
Steel macro fibres have a specific gravity near 7.85 and an elastic modulus near 210 GPa. They contribute significant post-crack flexural capacity but generate corrosion staining, pumping equipment wear, and higher dead load. STRUX 85/50, at 0.91 specific gravity and 9.5 GPa elastic modulus, is selected where corrosion resistance, surface appearance, and pump abrasion are constraints. Polypropylene microfibres with equivalent diameters typically below 0.1 mm and lengths of 6 mm to 19 mm are dosed at 0.6 kg/m³ to 1.2 kg/m³ for plastic shrinkage control only. STRUX 85/50 has a 50 mm length and a 0.59 mm equivalent diameter, which permits macro-crack bridging after the concrete matrix has cracked.
| Property | STRUX 85/50 | Steel macrofibre | PP microfibre |
|---|---|---|---|
| Density | 0.91 g/cm³ | 7.85 g/cm³ | 0.90–0.92 g/cm³ |
| Nominal length | 50 mm | 30–60 mm | 6–19 mm |
| Equivalent diameter | 0.59 mm | 0.5–1.0 mm | 0.02–0.10 mm |
| Tensile strength | 620 MPa | 1,000–2,000 MPa | 300–500 MPa |
| Elastic modulus | 9.5 GPa | 190–210 GPa | 3.5–7.0 GPa |
| Common dosage | 2.0–9.0 kg/m³ | 15–60 kg/m³ | 0.6–1.2 kg/m³ |
A further distinction is volume fraction. At 4.5 kg/m³, STRUX 85/50 contributes approximately 0.49% by volume of concrete; steel fibres at 30 kg/m³ contribute approximately 0.38% by volume. The synthetic fibre therefore introduces a comparable number of discrete reinforcing elements but with a lower elastic modulus. This is why the product is positioned for crack control and toughness rather than for replacement of conventional steel bar or welded wire reinforcement in load-bearing flexural members.
During full-scale batching, STRUX 85/50 is introduced into the mixer after the coarse aggregate and water have been combined with the cementitious paste. In truck mixers, the fibre bundles are added over 45 s to 60 s at drum speed of 12 rpm to 16 rpm, followed by a further 4 min to 5 min at full mixing speed. Pan and twin-shaft compulsory mixers achieve dispersion more quickly, but the fibre must not be added into a dry mixture because electrostatic charge and high shear can lead to balling. Field records from ready-mix plants often show a slump reduction of approximately 20 mm to 30 mm at a dosage of 6 kg/m³ in a 20 mm maximum aggregate mix when measured under ASTM C143/C143M. This is normally offset by a Type F high-range water-reducing admixture under ASTM C494/C494M rather than by adding water.
Dispersion is evaluated on the fresh concrete visually and by washing out a sample under EN 14889-2:2006 quality-control procedures; residual clumps are considered a batching sequence failure. Air-entrained mixes require trial batching because macro fibres can alter the slump and air void spacing factor measured under ASTM C457/C457M. The fibre is compatible with air-entraining admixtures meeting ASTM C260/C260M, but the admixture dosage may require adjustment of 5% to 15% to maintain the specified air content.
Concrete containing STRUX 85/50 can be placed with conventional straight-line or boom pumps. The main operational variable is the increased paste demand created by the large specific surface area. For a 0.59 mm equivalent diameter and 50 mm length, a single fibre has a mass of approximately 12.4 mg and a surface area of approximately 9.27 × 10⁻⁵ m². At a dosage of 4.5 kg/m³, the concrete contains approximately 3.6 × 10⁵ fibres and 33.5 m² of additional polymer surface per cubic metre. Mix designs with paste volumes below 280 L/m³ may require viscosity-modifying admixture or increased cementitious content to maintain pumpability. In slip-form paving and laser-screeded slabs, the fibre length of 50 mm must be less than one-half the minimum section thickness; for 100 mm slabs this condition is satisfied.
In self-compacting concrete, STRUX 85/50 can be used at dosages up to 6.0 kg/m³ if the paste volume and high-range water-reducing admixture are adjusted. Slump flow measured under EN 12350-8 typically decreases by 40 mm to 70 mm at 4.5 kg/m³ compared with the same mix without fibres; passing ability measured under EN 12350-10 may require trial adjustment. Segregation resistance measured by EN 12350-11 is generally improved by the fibre network if the aggregate skeleton is stable.
At dosages above 4.5 kg/m³ in concrete with a slump below 100 mm, dispersion energy becomes the controlling process variable. The number of fibres per cubic metre approaches 4.8 × 10⁵ at 6 kg/m³ and 7.2 × 10⁵ at 9 kg/m³. In high-shear pan mixers, the fibre addition point should be shifted to the wetted aggregate stream, and the total mixing time after fibre addition should be extended by 30 s to 60 s. If the concrete is discharged before the fibres are separated, macro fibre balls can obstruct pump reducers and travelling vibrators. Plant operators monitor mixer amperage; an amperage increase above the unfibred baseline of 10% to 15% frequently indicates incomplete dispersion or an excessive dosage for the paste volume. The material can be finished with power trowels, but exposed-surface trials are necessary because fibres can produce a slight surface fuzz when the slab is overworked. Burnished or broadcast-aggregate finishes require a trial panel to evaluate fibre protrusion before specification acceptance.
In low-slump sprayed concrete, dosages above 4.5 kg/m³ require pilot tests with the specific wet-mix rig. Rebound and line pressure vary with accelerator type and nozzle distance. Published data for this specific product under accelerated alkali-free set accelerators are limited, so each shotcrete mix must be qualified against EN 14487-2 or ACI 506R guidance.
In precast tunnel linings, fibre dosages between 4.0 kg/m³ and 9.0 kg/m³ are used with self-compacting or low-slump mixes to improve damage resistance during demoulding and transportation. The 50 mm fibre can bridge 20 mm aggregate gaps but may arch in congested reinforcement if the clear spacing is less than approximately 1.5 times the fibre length. Narrow pump line reducers and shear gates should be checked to confirm that the clear opening is at least 3 times the fibre length.
Post-crack performance is determined by third-point flexural loading of 150 mm × 150 mm × 500 mm beams under ASTM C1609/C1609M. The test reports first-peak strength, residual strengths at net deflections of L/600 and L/150, and toughness to a net deflection of L/150. Macro synthetic fibres with 50 mm length and 85 aspect ratio typically produce residual strength ratios in the range of 20% to 45% of first-peak strength at dosages of 3.0 kg/m³ to 6.0 kg/m³; product-specific published data for STRUX 85/50 are limited. For design, the notched beam test under EN 14651:2005+A1:2007 provides limit-of-proportionality and residual flexural tensile strength classes. The product should not be substituted for primary reinforcement in structural elements unless a licensed design engineer has prepared a fibre-reinforced concrete design based on tested post-crack parameters.
In ground-supported slabs, the structural contribution of STRUX 85/50 depends on the residual flexural strength class, not on the fibre tensile strength alone. Design procedures such as the slab-on-ground method in ACI 360R-10 or the Concrete Society TR34 approach may be applied when the tested post-crack parameters are known. Joint spacing, slab thickness, and subgrade modulus interact with the fibre residual strength; increasing dosage from 3.0 kg/m³ to 6.0 kg/m³ may allow wider joint spacing or reduced slab thickness for a given load, but the design must be verified by ASTM C1609/C1609M or EN 14651 test results. Unverified correlations between dosage and thickness reduction are not technically valid.
The PP/PE matrix is resistant to the high-pH pore solution of concrete, chlorides, sulfates, and common mineral acids at ambient temperature. Unlike steel fibres, STRUX 85/50 does not produce corrosion staining or require galvanic protection. The polymer backbone contains no ester, amide, or cellulosic linkages that undergo hydrolysis in saturated calcium hydroxide solution at pH above 13. Chloride ions do not attack the fibre surface; therefore the product can be used in marine or chloride-laden environments where steel fibres would require galvanized or stainless grades.
The polyolefin matrix softens as temperature approaches 120 °C and melts near 160 °C; therefore the fibre is not suitable for refractory concrete, autoclaved aerated product cycles above 150 °C, or prolonged continuous service above 80 °C unless product-specific thermal ageing data are available. Bags should be protected from direct sunlight for prolonged storage to avoid ultraviolet embrittlement of the polymer surface, although the fibre inside hardened concrete is fully shielded.
Factory production control for STRUX 85/50 is documented under EN 14889-2:2006 and, where applicable, the Construction Products Regulation (EU) 305/2011. Conformity assessment procedures for Class II fibres require initial type testing by a notified body and routine factory inspection. Incoming inspection should verify fibre length, bundle integrity, and mass per package. Fibres that show melting, fusing, or visible contamination from petroleum products should be quarantined and not introduced into the mixer.
| Requirement | Reference | Classification or limit |
|---|---|---|
| Synthetic macrofibre classification | ASTM C1116/C1116M | Type III |
| Polymer fibre classification | EN 14889-2:2006 | Class II |
| Flexural performance testing | ASTM C1609/C1609M | Beam, 150 mm × 150 mm × 500 mm |
| Notched beam testing | EN 14651:2005+A1:2007 | 25 mm notch, 150 mm × 150 mm section |
| Fresh concrete slump | ASTM C143/C143M | Product-specific trial |
| Air void system assessment | ASTM C457/C457M | Trial batching required |
| Construction Products Regulation | (EU) 305/2011 | CE marking |