Liwei Group Co., Ltd

Products

MasterFiber 154 SPA - Polypropylene Macro Fiber for Concrete and Sprayed Concrete

    • Product Name: MasterFiber 154 SPA - Polypropylene Macro Fiber for Concrete and Sprayed Concrete
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 955939
    Product Name MasterFiber 154 SPA
    Manufacturer Master Builders Solutions
    Material Polypropylene
    Fiber Type Macro synthetic fiber
    Application Concrete and sprayed concrete
    Fiber Length 54 mm
    Fiber Diameter 0.80 mm
    Aspect Ratio 68
    Density 0.91 g/cm³
    Tensile Strength 400 MPa
    Elastic Modulus 6 GPa
    Melting Point 160 °C
    Alkali Resistance Excellent
    Water Absorption Nil
    Recommended Dosage 2.0 - 9.0 kg/m³
    Packaging 5 kg bags
    Color Grey

    As an accredited MasterFiber 154 SPA - Polypropylene Macro Fiber for Concrete and Sprayed Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing MasterFiber 154 SPA packaging: 20 kg cartons, each containing 10 water-soluble bags of 2 kg, for concrete and sprayed concrete.
    Container Loading (20′ FCL) 20′ FCL container loaded with palletized MasterFiber 154 SPA polypropylene macro fiber bags, securely stowed for concrete and sprayed concrete.
    Shipping MasterFiber 154 SPA – Polypropylene Macro Fiber for Concrete and Sprayed Concrete is shipped as a non-hazardous material in sealed, moisture-resistant 20 kg bags, stacked on pallets and stretch-wrapped. Store in a cool, dry area; protect from punctures, moisture, and direct sunlight. Standard transport regulations apply.
    Storage Store MasterFiber 154 SPA in its original, unopened packaging indoors in a dry, cool, well-ventilated area. Protect from direct sunlight, moisture, and extreme heat; keep away from ignition sources and open flames. Maintain stable pallets, avoid excessive stacking, and rotate stock. Keep clean and free from contaminants. Properly stored, shelf life is typically indefinite.
    Shelf Life Shelf life is 24 months from manufacture when stored in unopened original packaging, dry conditions, protected from moisture, direct sunlight, and extreme temperatures.
    Application of MasterFiber 154 SPA - Polypropylene Macro Fiber for Concrete and Sprayed Concrete

    Slab-on-grade construction in automated logistics facilities uses MasterFiber 154 SPA at 3.0–5.0 kg/m³ to replace light-gauge steel mesh in crack-control design where bay sizes exceed 2,500 m² and pallet-shuttle rail storage systems impose wheel loads above 2.5 t per wheel. The compliance basis is Concrete Society TR34 (2016) for ground-bearing slab design, ASTM C1609/C1609M-23 for flexural performance, and EN 14889-2:2006 for CE marking of polymer macro fibres. On production floors, batching in twin-shaft compulsory mixers with 0.5–2.0 m³ batch capacity places fibre after aggregate discharge but before cement and admixtures; a 30–45 s dry-mix phase before water introduction prevents agglomeration at dosages above 4.0 kg/m³. Concrete is placed by laser screed with hydraulic profiling to a tolerance of ±5 mm over 3 m and power-floated in 8–10 passes; saw-cut contraction joints are formed 12–24 h after final finishing at spacing not exceeding 6 m, and post-crack residual strength at 3 mm crack-mouth opening displacement is evaluated according to ASTM C1609/C1609M-23. Polycarboxylate ether superplasticizer at 0.8–1.2% by mass of cement restores 150–180 mm slump without increasing water-cement ratio; batch records indicate 10–20 mm slump loss when dosage is raised from 3.0 kg/m³ to 5.0 kg/m³. End product types include high-bay distribution centre slabs, automated pallet shuttle floors, and cold-store freezer floors where steel mesh is rejected due to thermal conductivity and joint-edge corrosion risks.

    What governs the switch from welded mesh to macro polypropylene fibre in wet-mix sprayed concrete for NATM primary linings?

    During wet-mix sprayed concrete application for NATM primary linings, the transition away from welded mesh is governed by the required energy absorption class under EN 14488-5 panel testing and the rock mass behaviour after face excavation. MasterFiber 154 SPA is batched at 5.0–7.5 kg/m³; at 5.0 kg/m³, EFNARC European Specification for Sprayed Concrete (1999/2001) panel energy absorption is typically evaluated against class E500, while 7.0 kg/m³ requires verification for E1000 in 100 mm-thick linings. Compliance references include EN 14487-1:2022 for sprayed concrete specification, EN 14889-2:2006 for fibre conformity, ASTM C1550-20 for round panel flexural toughness, and ACI 506R-21 for shotcrete practice. The wet-mix is pumped through 50 mm internal-diameter hose with double-piston or S-valve pumps; at the nozzle, air at 6.0–8.0 bar is introduced and alkali-free accelerator dosed at 5–8% by mass of cement. Production-scale observations from tunnel sites show that blockages are concentrated at 90° hose couplings and reductions below 50 mm internal diameter, while rebound of polypropylene macro fibre is visually assessed after each advance and should remain below 15% under optimum nozzle angle and accelerator dosage. Fibre addition occurs during batch mixing, not at the nozzle; batch-to-batch variance in residual strength is controlled by verifying fibre mass per m³ against the loading conveyor weight ticket and by sampling round panels for every 50 m³ of applied concrete. Published round panel data for this specific formulation under ASTM C1550-20 is limited; project-specific qualification to EN 14488-5 is therefore required before mesh substitution. End product types include single-shell drift linings, NATM cross-passage collars, rock slope drape support, and portal stabilisation aprons in spans requiring temporary support without steel mesh corrosion risk.

    When thin-cover precast culvert units cannot accept welded mesh without exposing it to chloride ingress

    Dry-cast precast concrete for box culverts and drainage channels incorporates 2.5–4.0 kg/m³ MasterFiber 154 SPA in sections where welded mesh cannot maintain 25 mm minimum cover without producing reinforcement shadowing and corrosion at the casting face. Compliance for this scenario is drawn from EN 13369:2018 common rules for precast concrete, EN 14889-2:2006 for the fibre's Declaration of Performance, and EN 1916:2002 for concrete pipes where applicable; flexural verification uses EN 14651:2005+A1:2007 for post-crack tensile strength. The dry-cast process runs at 0–15 mm slump with aggregate-cement ratios of 5.5–6.5:1 and is placed by downward vibration on hydraulic pressing machines; steam curing at 60 °C for 14–16 h achieves demould strengths of 20–25 MPa. The dosage window is narrow because an increase from 2.5 kg/m³ to 4.0 kg/m³ can reduce green strength by 0.1–0.3 MPa unless water demand is offset with a melamine or polycarboxylate admixture at 0.5–1.0% by mass of cement. End product types include U-channels, twin-wall culvert units, headwalls, and agricultural drainage channels where the fibre replaces corner mesh and reduces chipping during transport.

    Compliance matrix for MasterFiber 154 SPA downstream applications
    Standard designationTest method or specification focusDownstream application boundary
    EN 14889-2:2006CE marking and Declaration of Performance for polymer macro fibresAll concrete and sprayed concrete applications
    EN 14487-1:2022Specification for sprayed concreteNATM tunnel linings, rock stabilisation, repair linings
    ASTM C1609/C1609M-23Flexural performance of fibre-reinforced concrete using beam with third-point loadingSlab-on-grade, composite decks, precast
    ASTM C1550-20Flexural toughness of round panel shotcreteSprayed concrete ground support
    Concrete Society TR34 (2016)Joint design and post-crack flexural strength in ground-supported slabsLogistics floors and container yards
    EN 1504-3:2005Structural and non-structural repair product class R4Marine repair linings

    Container terminal hardstandings and intermodal yards require macro fibre addition rates that maintain flexural toughness under straddle-carrier steering manoeuvres and corner-point loads from 40-foot containers. MasterFiber 154 SPA is introduced at 4.0–6.0 kg/m³ in 300–350 mm-thick plain concrete pavements where dowels and tie bars remain at movement joints but crack-control mesh is removed. The design and verification platform is Concrete Society TR34 (2016) for ground-supported slabs and ASTM C1609/C1609M-23 for third-point flexural testing; post-crack residual strength values are reported at net deflections of L/150 and L/600 to match joint design assumptions. On slipform paving trains with 12 m wide forms and automatic dowel bar inserters, fibre is batched through mobile volumetric mixers or central mix plants; the slipform paver's vibrator frequency must be reduced to 7,000–9,000 vibrations per minute when dosage exceeds 5.0 kg/m³ to avoid fibre orientation collapse near the surface. Immediately after the paver, transverse joint saw cutting occurs 6–12 h after placement and a sprayed curing compound meeting ASTM C309 is applied. Edge slump, plastic shrinkage crack formation, and fibre balling at delivery are the main production bottlenecks; balling incidence rises when fibre is added after water and superplasticizer, so dosing sequence at the central mix plant is aggregate-fibre-cement-water. End product types include container stacking areas, rubber-tyred gantry crane lanes, intermodal rail sidings, and airport service roads subject to concentrated axle loads.

    Composite slab pours on profiled steel decking with shear studs

    In composite floor construction, the decision to use MasterFiber 154 SPA at 3.0–4.5 kg/m³ is driven by plastic shrinkage cracking above corrugation valleys and the hazard of carrying welded mesh over shear studs. Compliance includes EN 1994-1-1:2004 for composite design, EN 13670:2009 for execution of concrete structures, EN 14889-2:2006 for fibre conformity, and ASTM C1581/C1581M-21 for restrained shrinkage cracking where specified. Pumped concrete with 180–220 mm slump is delivered through 250–350 mm boom lines; the macro fibre length must not exceed 0.45 times the minimum cover to maintain pumpability through reducing sections. After placement, power trowels finish the slab in 6–8 passes, and low-speed blade settings are used to prevent fibre lift. The addition ratio replaces mesh for crack control but does not replace any structural deck reinforcement or shear connectors; design calculations under EN 1994-1-1:2004 must separately account for the steel deck's composite action. End product types include multi-storey car park decks, commercial building composite floors, and mezzanine slabs where fire-resistance classification requires separate EN 1363-1 testing because polypropylene fibre melting at 160–170 °C cannot be used as the sole passive fire protection measure.

    Eliminating welded mesh from tidal and splash-zone marine repair linings

    Spray-applied repair linings in tidal and splash-zone marine structures eliminate galvanized welded mesh to avoid chloride-induced mesh corrosion when cover is reduced to 50 mm; MasterFiber 154 SPA is batched at 5.0–6.5 kg/m³ to maintain post-crack residual strength in thin overlays. The compliance stack is EN 1504-3:2005 Class R4 for structural repair products, EN 14487-1:2022 for sprayed concrete, EN 14889-2:2006 for fibre CE marking, and EN 14651:2005+A1:2007 for flexural post-crack tensile strength. Dry-mix spraying with a rotary gun and 7 m³/min air compressor introduces water at the nozzle at 0.45–0.55 water-cement ratio; prepackaged mortar containing the fibre is fed through a 25 mm hose for vertical and overhead patch repair. Rebound in overhead marine work exceeds vertical repair rebound and must be monitored by section thickness checks at every 10 m²; a 10–15 mm first-pass thickness is typical before building up to 50 mm. The macro fibre is not a corrosion inhibitor for embedded steel: when the existing structural steel has chloride content above 0.4% by mass of cement, the repair system requires supplementary electrochemical protection or migration corrosion inhibitors to prevent residual chloride activity. End product types include quay wall pile encasement, bridge pier splash-zone repair, outfall culvert lining, and sheet-pile coating replacement.

    Free Quote

    Competitive MasterFiber 154 SPA - Polypropylene Macro Fiber for Concrete and Sprayed Concrete prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber 154 SPA is a polypropylene macro synthetic fiber supplied for concrete and sprayed concrete applications. The material is classified under EN 14889-2:2006 as a Class II polymer macrofiber when the equivalent diameter exceeds 0.3 mm and under ASTM C1116/C1116M as a Type III synthetic fiber-reinforced concrete component. The base polymer is an isotactic polypropylene with a typical specific gravity of approximately 0.91 and a melting point in the range 160 °C to 170 °C. This places MasterFiber 154 SPA among the low-density, chemically inert macrofibers used to improve post-crack toughness and residual strength rather than to control plastic shrinkage alone. Product-specific geometrical values for length, equivalent diameter, tensile strength, and elastic modulus must be taken from the manufacturer’s current declaration of performance and lot-specific certification. The product is introduced into concrete at the batching plant or at the shotcrete machine through controlled dosing equipment, and its performance is evaluated through flexural residual strength and sprayed-concrete energy absorption test methods.

    In the context of construction product conformity, MasterFiber 154 SPA is subject to the factory production control and initial type-testing obligations of EN 14889-2:2006. The standard requires declaration of the nominal length, equivalent diameter, tensile strength, elastic modulus, and alkali resistance of the polymer fiber. Under the EU Construction Products Regulation 305/2011, the CE marking therefore communicates conformity to a declared set of technical values; it does not by itself confirm equivalence to steel reinforcement or suitability for a specific structural application. For projects outside the EU, compliance is often evaluated against ASTM C1116/C1116M and the relevant ASTM test methods, but the user should also verify regional concrete code acceptance. The product must be accompanied by a delivery note that links the lot identifier to the declared property sheet so that batch-to-batch geometry changes can be identified before installation.

    Where macrofiber classification becomes operationally significant

    The distinction between Class I and Class II polymer fibers under EN 14889-2:2006 is not administrative. Class I microfibers, typically shorter than 12 mm and added at 0.6 kg/m³ to 2.0 kg/m³, act mainly on plastic shrinkage cracking and plastic settlement. Class II macrofibers, such as MasterFiber 154 SPA, require larger geometry and higher addition rates, commonly in the range 3 kg/m³ to 9 kg/m³, to engage across cracks and provide residual flexural strength. The mechanism of crack bridging is geometrical: the macrofiber must be long enough to transfer stress across a crack opening and stiff enough relative to the concrete matrix to generate residual load. Polypropylene has an elastic modulus lower than steel; therefore the post-crack capacity of a polypropylene macrofiber mixture is generally lower than that of an equivalent steel fiber dosage at small crack widths. The user should not substitute the fiber type solely on a mass-for-mass basis. The overdesign should be based on measured fR1 and fR4 values from EN 14651:2005+A1 or residual strength ratio data from ASTM C1609/C1609M.

    At production scale, sequential addition of MasterFiber 154 SPA in a compulsory mixer is performed after the initial wetting of fine materials and before the mixture reaches a high-viscosity state. If the fiber is added simultaneously with dry cement and aggregate, the polypropylene strands can accumulate around mixer paddles and form fiber balls, particularly in high-speed pan mixers with tip speeds above 3 m/s. Observed failure modes on actual batching lines include bridging at the feed gate, poor fiber distribution in the first 0.5 m³ of discharge, and return of rebound material with fiber clumps in sprayed concrete operations. A calibrated mechanical screw feeder or conveyor interlocked with the batch controller should be used to maintain a feed rate consistent with the batching time. Weighing tolerance for fiber addition in continuous plants should not exceed ±2 % of the target mass per batch, and pre-weighed bags should be introduced whole or opened by an automatic bag splitter rather than torn manually in high-production conditions.

    The addition of MasterFiber 154 SPA does not require extra mixing water because polypropylene is hydrophobic and does not absorb free mix water. Fresh concrete slump and air content should still be verified under EN 12350-2 and EN 12350-7 because the increased solid volume and fiber entanglement can reduce flow and alter air-void coalescence. In high-range water-reducing concrete, the fiber can interact with polycarboxylate ether superplasticizers through changes in paste-film thickness around the macrofiber surface; no chemical decomposition is expected, but workability retention should be checked with field trials. If the mix is to be pumped, a pumpability test based on a piston pump with at least 100 m of pipeline is often specified in tunnel shotcrete projects. The fiber length must be less than half the minimum pump line diameter to prevent plugging; this is a geometric compatibility requirement rather than a material limitation.

    What separates polypropylene macrofiber from steel fiber and Class I microfibers?

    The selection of MasterFiber 154 SPA over steel macrofiber is usually driven by corrosion resistance, electrical non-conductivity, mass reduction, and handling safety. Steel fibers under EN 14889-1:2006 provide a higher elastic modulus, approximately 200 GPa to 210 GPa, and can deliver higher residual flexural strength at low crack widths. Polypropylene macrofibers occupy the lower-modulus band, approximately 3 GPa to 10 GPa, and therefore require larger crack widths to mobilize significant tensile load. This material difference appears in structural design as lower fR1 and fR4 values at the same fiber dosage; the comparison must be made on the basis of measured beam performance, not fiber mass. In aggressive environments, steel fibers can corrode at exposed concrete surfaces, whereas polypropylene macrofibers do not undergo electrochemical corrosion. For applications with strong electromagnetic fields or where diamagnetic equipment is used, polypropylene is effectively nonconductive. Compared with polypropylene microfibers, which are dosed at 0.6 kg/m³ to 2.0 kg/m³ to suppress plastic shrinkage, MasterFiber 154 SPA is intended for higher-volume post-crack applications. The following table summarizes the main class distinctions.

    Property Steel macrofiber Polypropylene macrofiber Polypropylene microfiber
    Primary standard EN 14889-1:2006 EN 14889-2:2006 Class II EN 14889-2:2006 Class I
    Specific gravity 7.85 0.90–0.92 0.90–0.91
    Elastic modulus 200–210 GPa 3–10 GPa 1–5 GPa
    Typical dosage 15–40 kg/m³ 3–9 kg/m³ 0.6–2.0 kg/m³
    Primary function Post-crack flexural strength and structural residual strength Post-crack toughness and corrosion-resistant crack bridging Plastic shrinkage and settlement crack control
    Corrosion behavior Susceptible at exposed surfaces Inert Inert

    The tabular ranges are class-level industrial values, not product-specific values for MasterFiber 154 SPA. Published data for this specific configuration may be limited; the product must be validated through laboratory trial batching and in situ panel work before mass application. In particular, the fR1 and fR4 ratios are matrix-sensitive and cannot be read from material density alone.

    In sprayed concrete production, MasterFiber 154 SPA is normally dosed at the batching plant into the wet-mix truck or through a calibrated screw feeder at the nozzle feed. The feed screw must be interlocked with the concrete mass flow so that the fiber mass per cubic metre remains within the approved dosage band. For tunnel shotcrete, the required energy absorption class is usually defined by EN 14487-2 or project-specific classes under EN 14488-5:2006, such as E500, E700, or E1000. The fiber dosage required to reach a given energy absorption class is not a fixed material property; it depends on the water-to-binder ratio, the paste content, the type and dosage of accelerator, the spray operator, and the rebound level. In practice, a preconstruction trial should include full-scale nozzle spraying of panels, measurement of rebound, and laboratory energy absorption tests on cored specimens. Fiber rebound in wet-mix sprayed concrete is often greater than the aggregate rebound because the low-density polypropylene fiber is preferentially lost at the nozzle impingement face; the rebound fraction should be measured by difference between batched mass and hardened in-situ fiber content. If the measured in-situ fiber content falls below the lower declared value, the toughness class cannot be assumed to be met.

    Dry-mix sprayed concrete presents a different constraint. Polypropylene macrofiber must be pre-blended with cement and aggregate before the nozzle water ring because adding it at the water ring produces uneven fiber distribution and local balling. The fiber length must be compatible with the internal surfaces of the rotary gun and the hoses; blockages occur when fibers longer than half the minimum hose diameter bridge across bends. Published data for this specific configuration is limited, so the equipment manufacturer’s hose-diameter recommendation should be compared with the fiber geometry before dry-mix trials are authorized.

    If the design residual strength requirement exceeds the fiber’s modulus

    Polypropylene macrofiber is not a direct substitute for steel fiber when the structural design relies on high residual flexural strength at small crack openings. The lower elastic modulus of polypropylene means that crack widths must increase before the fibers mobilize significant load. Where a European design uses EN 14651:2005+A1 and specifies fR1 and fR4 values above what initial trial mixtures achieve, the concrete mixture must be redesigned with high paste volume, reduced maximum aggregate size, or higher fiber dosage. Increasing MasterFiber 154 SPA dosage beyond 9 kg/m³ can lead to fresh concrete workability loss, fiber clumping, and non-uniform distribution; therefore an upper dosage should be fixed through trial mixing rather than assumed from static property tables. If the project specification calls for steel-fiber residual strength at the same dosage, published data for this specific configuration is limited, and beam tests must be carried out before approval. The product’s distinctive value in aggressive environments, where steel fiber corrosion is undesirable, should be weighed against the lower modulus through design calculations rather than assumed equivalence.

    For concrete exposed to chloride or sulfate, polypropylene macrofiber does not corrode, but it also does not reduce chloride ingress. The concrete cover, binder chemistry, and water-to-binder ratio remain the primary controls under EN 206, ACI 318, or the applicable national annex. The use of MasterFiber 154 SPA does not remove the need for corrosion-protected steel reinforcement or crack-width limits in the parent design. At high temperatures above approximately 160 °C, polypropylene softens and can lose load-carrying capacity; it is not a structural reinforcement solution in fire-rated members. In fire scenarios, polypropylene fibers may influence pore pressure and spalling, but this role is usually assigned to microfibers and requires fire-specific testing such as ISO 834 or national tunnel fire curves.

    At the point of production, the user should verify that the lot-specific delivery note identifies the nominal length, equivalent diameter, and declared residual strength class of MasterFiber 154 SPA. The batch computer should record the actual fiber mass per batch and the moisture content of the aggregate because the effective fiber content by volume is a function of the concrete batch volume. For shotcrete operations, the inspector should retain daily records of the fiber feed calibration, the nozzle feed rate, and the rebound panels. The product is considered verified for the project when the trial beam data under EN 14651:2005+A1 or ASTM C1609/C1609M demonstrate the specified fR1 and fR4 or residual strength ratio values, and when the sprayed-concrete panels under EN 14488-5:2006 exceed the specified energy absorption class. Published data for this specific configuration may be limited beyond the manufacturer’s current declaration of performance, so these project-specific verifications are not optional.