Liwei Group Co., Ltd

Products

MasterFiber 230 SPA - Polypropylene Macro Fiber

    • Product Name: MasterFiber 230 SPA - Polypropylene Macro Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 714019
    Productname MasterFiber 230 SPA - Polypropylene Macro Fiber
    Material 100% virgin polypropylene
    Fibertype Macro synthetic fiber
    Fiberlength 54 mm
    Equivalentdiameter 0.65 mm
    Aspectratio 83
    Tensilestrength 550 MPa
    Elasticmodulus 10 GPa
    Elongationatbreak 20%
    Meltingpoint 160 °C
    Density 0.91 g/cm³
    Alkaliresistance Excellent
    Waterabsorption Negligible
    Chemicalresistance Good
    Typicaldosage 3.0-6.0 kg/m³
    Packaging 10 kg bags
    Color Gray
    Compliance ASTM C1116 Type III; EN 14889-2

    As an accredited MasterFiber 230 SPA - Polypropylene Macro Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing MasterFiber 230 SPA comes in 1 lb (0.45 kg) water-soluble bags, with 40 bags per carton, palletized for easy handling.
    Container Loading (20′ FCL) A 20′ FCL container loaded with MasterFiber 230 SPA polypropylene macro fiber, securely palletized and braced for safe ocean transport.
    Shipping MasterFiber 230 SPA – Polypropylene Macro Fiber is shipped in original sealed bags/cartons, palletized and stretch-wrapped. It is not classified as hazardous for transport (DOT/IMDG/IATA). Store and transport in a dry, ventilated area, protected from moisture, direct sunlight, and extreme temperatures. Handle carefully to avoid package damage.
    Storage Store indoors in a dry, clean, well-ventilated area using original unopened packaging. Protect from moisture, direct sunlight, extreme temperatures, and prolonged UV exposure. Keep away from open flames, heat, and strong oxidizers. Do not stack pallets excessively. Maintain good housekeeping to prevent contamination, and use first-in, first-out stock rotation. Observe manufacturer shelf-life and handling recommendations.
    Shelf Life Shelf life is 24 months from date of manufacture when stored in original unopened packaging, dry, and protected from sunlight.
    Application of MasterFiber 230 SPA - Polypropylene Macro Fiber

    Wet-mix shotcrete lining operations in drill-and-blast tunnels and NATM excavations constitute a high-rate application zone for MasterFiber 230 SPA; the concrete matrix is designed not for slump retention but for pumpability, nozzle kinematics, and early-age energy absorption. The compliance corridor is defined by EN 14889-2:2006 for polymer fibre conformity and CE marking under Regulation (EU) No 305/2011, EN 14487-1:2005 for sprayed concrete specification, and ACI 506R-16 or EFNARC 1999 for placement. Addition rates in wet-mix shotcrete are typically 4.5–9.0 kg/m³, equivalent to 0.49–0.99% by volume at a polypropylene density of 0.91 kg/L; the lower bound requires verification under EN 14651:2005+A1:2007 because residual flexural strength can fall below temporary rock support acceptance limits when dosage is below 4.0 kg/m³. In the batching plant, the fibre is introduced after dry aggregates in a twin-shaft compulsory mixer with batch capacity between 1.0 m³ and 2.5 m³, or through the aggregate charging belt into a ready-mix truck, followed by water and superplasticizer; fibre addition ahead of water reduces hydrophobic accumulation on mixer blades. Production-scale experience with swing-tube piston pumps and 50–75 mm delivery lines indicates that pumping pressure rises less from the fibre itself than from poor air volume control at the nozzle; compressed air flow must be kept between 8 m³/h and 12 m³/h per line to keep rebound below 20% and to maintain the sand–fibre skeleton. Alkali-free accelerators dosed at 3–8% by cement weight are compatible with the polypropylene surface, but if the fibre dosage crosses 6.0 kg/m³, the accelerator demand curve must be re-tuned because the fibre network alters early-age plastic viscosity, as evidenced by flow table spread reduction of 10–20 mm under EN 12350-5:2019. Terminal products include primary and secondary tunnel linings, adits, access shafts, temporary rock support shells, and slope stabilization layers, in which the macro fibre replaces welded wire mesh and eliminates mesh pinning near fractured rock. A boundary condition for this scenario is the maximum practical dosage: beyond 9.0 kg/m³, nozzle clogging risk and rebound penalties require full-scale pump and nozzle trials under the specific accelerator and air flow configuration.

    How Does Polypropylene Macro Fibre Alter Precast Demoulding and Durability Windows?

    In precast segment plants, the governing challenge is not pumpability but the balance between fibre dispersion and form-face finish during accelerated curing. Compliance for precast concrete incorporating MasterFiber 230 SPA is anchored to EN 14889-2:2006 for the fibre product and EN 13369:2018 for common concrete precast product rules, with flexural verification under EN 14651:2005+A1:2007 or ASTM C1609/C1609M-19a. The formulation addition rate is typically 3.0–6.0 kg/m³ (0.33–0.66% by volume); 5.0 kg/m³ acts as a transition dosage because below that level the fibre mainly suppresses handling cracks and demoulding impact damage, while above it residual flexural strength begins to be specified for segment stacking and TBM thrust loads. The downstream production process uses pan mixers of 0.75–2.0 m³ charged with dry aggregate, cement, and fibre through the plant weigh hopper; wet mixing time is extended by 10–20 s relative to plain concrete, but total wet mixing should not exceed 30–45 s beyond baseline to prevent fibre entanglement and airborne fibre dust. Vibration table settings in the 50–80 Hz band with 0.5–1.0 mm amplitude are adjusted upward once fibre dosage exceeds 4.0 kg/m³; however, external form vibrators must be limited to 20–30 s per station because prolonged vibration drives fibre migration and produces visible surface striations on the form face. Terminal products include TBM precast segments, box culverts, manhole risers, cable troughs, light rail parapets, and drainage channels. A release agent incompatibility exists with heavy mineral-oil solvent-based products: they can interact with residual fibre dust on aggregate surfaces and create surface voids, so water-emulsifiable release agents applied at 45–60 g/m² are specified. The operational boundary is structural: MasterFiber 230 SPA is not a direct replacement for primary flexural steel in high-moment precast beams unless the structural design explicitly uses the post-crack tensile capacity of fibre-reinforced concrete under the project-specific design code.

    Industrial Slab-on-Grade Joint Activation and Curling Response

    For industrial floors with high-rack traffic, joint activation and curling response are governed by the post-crack residual capacity at the slab surface, where temperature and moisture gradients concentrate tensile strain. The applicable compliance set includes ACI 360R-10 for slab-on-ground design, ASTM C1116/C1116M-10a Type III for synthetic fibre reinforced concrete, and ASTM C1609/C1609M-19a or EN 14651:2005+A1:2007 for flexural toughness acceptance. Addition rate is fixed between 2.5 kg/m³ and 5.0 kg/m³ (0.27–0.55% by volume); the top of this range is used when the floor is designed to activate saw-cut joints before uncontrolled mid-panel cracking occurs at a crack mouth opening displacement of 0.5 mm. In ready-mix production, the concrete is delivered at 100–150 mm slump because the macro fibre typically reduces observed slump by 10–20 mm at 4.0 kg/m³; truck mixer drum speed is maintained at 8–12 rpm for 5–7 min after batch acceptance to homogenise the fibre without excessive shearing. Placement with a laser screed at slab thicknesses of 150–200 mm is standard; ride-on trowels with pan floats must not engage until surface bleed water has evaporated, as premature trowelling smears the paste over fibre ends and creates surface fuzzing after wear. Joint spacing can be extended only when dosage is kept above 4.0 kg/m³ and flexural performance is confirmed by ASTM C1609/C1609M-19a; saw-cutting must nevertheless be completed within 4–8 h after final finishing. Terminal end products are distribution centre floors, automotive manufacturing plants, freezer warehouses, truck marshalling yards, and mezzanine floor slabs. The specific limitation for rack-loaded floors is that high point loads require structural design fallback to steel bar or steel fibre reinforcement; the polypropylene macro fibre provides crack-control and toughness but not a substitute for flexural steel ratio unless the design engineer explicitly uses residual tensile capacity in accordance with a recognised FRC design code.

    When a container terminal pavement is designed without welded wire mesh, the fatigue response under laden forklift and container-handling traffic is governed substantially by the post-crack flexural energy of the concrete matrix. MasterFiber 230 SPA in rigid pavement is specified under ASTM C1116/C1116M-10a Type III, ACI 330R-08 for concrete parking lots and site paving, and ASTM C1609/C1609M-19a for flexural performance. Formulation addition rates are set between 3.0 kg/m³ and 7.5 kg/m³ (0.33–0.82% by volume); 5.0 kg/m³ is the common threshold for substitution of welded wire mesh in jointed plain concrete pavements carrying heavy container stackers. In fixed-form paving, the fresh-state workability is controlled at 25–75 mm slump, while slipform applications use 15–40 mm to maintain edge stability; dosages above 7.0 kg/m³ can disrupt slipform edge stability because the fibre network delays air-void migration and can cause tearing along paver side plates. Slipform paver vibration frequency is typically 6,000–10,000 vpm; when fibre content rises above 5.0 kg/m³, vibrator spacing should be reduced by 10–15% to avoid honeycombing behind the paver. Transverse joint sawing must be performed within 4–12 h after placement depending on concrete temperature, because late sawing creates random mid-panel cracking that overrides the fibre's crack-control function. Terminal products include container terminal pavements, intermodal yards, bus rapid transit lanes, access roads, and heavy-duty parking lots. De-icing salt exposure does not corrode the polypropylene fibre, but the cementitious matrix still must resist chloride ingress; if sulphate-resistant cement or high-volume supplementary cementitious materials are specified, a separate trial batch is required because modified paste viscosity can shift the effective fibre dosage by 0.5–1.0 kg/m³. Published data for this specific configuration under sustained dynamic loading beyond 10 million load cycles is limited, so full-scale test sections with 28-day and 56-day flexural testing under ASTM C1609/C1609M-19a are recommended for project-specific acceptance.

    When Thin Bonded Overlays Replace Welded Wire Reinforcement in Repair Systems

    Thin bonded repair sections create a severe depth constraint that places MasterFiber 230 SPA as a replacement for welded wire mesh when minimum cover cannot be satisfied in 25–40 mm layers. The compliance basis is EN 1504-3:2005 for repair mortar classification, EN 14889-2:2006 for the polymer fibre, and ACI 546R-14 for concrete repair guidance. In repair overlays the dosage is 4.0–7.0 kg/m³ (0.44–0.77% by volume); below 4.0 kg/m³ the post-crack capacity in thin sections may not bridge crack widths above 0.2 mm, while above 7.0 kg/m³ the fresh-state cohesiveness can complicate hand finishing in confined pockets and vertical patches. The downstream repair process requires hydro-demolition or mechanical scarification to reach a bond-tested roughness of 3–5 mm, followed by mixing in a forced-action pan or continuous mixer with the fibre introduced as the final dry component to avoid early hydrophobic coating of coarse aggregate. Compaction is performed with roller or vibrating screeds; over-vibration beyond 15–20 s/m² can cause fibre settlement and reduce fibre density at the wearing surface. Terminal product types include bridge deck patching, car park ramp repairs, tunnel lining rehabilitation, wastewater channel overlays, and balcony repair slabs. Because thin overlays have high evaporation rates, curing compound is applied at 200–250 g/m² within 30 min of final finishing; without this step, plastic shrinkage cracks can appear before the fibre network reaches its post-crack capacity. A known incompatibility occurs with certain polymer latex modifiers that lower the air-void surface tension; when latex content exceeds 10% by cement weight, production-scale compatibility trials must be run because the modifier can destabilise the air-void system and alter fibre dispersion.

    Marine Hydraulic Structures Demand Crack Control Without Metallic Corrosion Pathways

    In cast-in-place marine concrete, chloride-induced corrosion of steel fibre or welded wire mesh is unacceptable, and MasterFiber 230 SPA provides crack control without a metallic corrosion pathway. The applicable standard set includes EN 206:2013+A2:2021 for concrete specification and exposure classes, EN 14889-2:2006 for polymer fibre conformity, and ASTM C1116/C1116M-10a Type III; abrasion resistance can be tested under ASTM C1138/C1138M-19. The addition rate is 3.0–6.0 kg/m³ (0.33–0.66% by volume), with the lower boundary reserved for massive unreinforced sections and the upper boundary for wave-washed splash zones and lock approach walls where crack width must be controlled below 0.2 mm to limit chloride ingress. The production process starts with ready-mix concrete with water-cement ratio not exceeding 0.40 for marine exposure class XS3; the fibre is added at the batching plant, and a minimum truck mixer drum speed of 10 rpm is maintained to prevent local fibre bundling during discharge. Immersion vibrators at 9,000–12,000 vpm are used for compaction; insertion spacing is reduced to 300 mm when fibre dosage exceeds 4.5 kg/m³ because the macro fibre network can trap air at standard spacing. Terminal products include revetment slabs, slip-formed seawall capping beams, breakwater armour units, canal liners, and harbour paving. A specific operational boundary applies to hydrostatic water-retaining structures: the fibre is not a waterstop and does not compensate for absence of construction joint waterbar systems. If air entrainment is specified for freeze-thaw exposure, the air content must be verified under EN 12350-7:2019 because polypropylene macro fibre can interact with air-entraining admixtures and shift air-void stability. In marine environments, published data for long-term performance beyond 20 years under continuous seawater immersion and tidal abrasion is limited; project specifications therefore often require a production-scale trial slab with 28-day and 56-day verification under EN 14651:2005+A1:2007.

    Free Quote

    Competitive MasterFiber 230 SPA - Polypropylene Macro Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber 230 SPA is a polypropylene macro-monofilament fiber supplied for secondary reinforcement of cast-in-place concrete, precast elements, and sprayed concrete. The product is characterized by a nominal length of 54 mm, an equivalent diameter of 0.83 mm, and a specific gravity of 0.91. Published manufacturer data report tensile strength of 620 MPa measured under ASTM D638-14 and elastic modulus of approximately 9.5 GPa. The polymer melt temperature is approximately 162 °C. The fiber is classified as a Type III synthetic fiber under ASTM C1116/C1116M-23. Compliance within the European framework is assessed under EN 14889-2:2006 for polymer fibers. The product is an embossed monofilament and therefore does not depend on fibrillation or bundle splitting during mixing. Its low density of 0.91 increases the number of discrete fibers per unit mass relative to steel fiber; however, the elastic modulus of 9.5 GPa is approximately 4.75 % of the 200 GPa modulus of cold-drawn steel. This stiffness differential defines the boundary between macro-synthetic and steel fiber in post-crack structural response.

    Storage conditions affect handling rather than fiber chemistry. The polypropylene fiber does not absorb water, and exposure to concrete pore solution at pH values up to 13.5 does not induce hydrolysis. The product must be protected from prolonged ultraviolet exposure because polypropylene undergoes photo-oxidative embrittlement. In highly fluid concrete with slump flow above 600 mm, the low density creates a flotation risk, and the mixture must be stabilized with a viscosity-modifying admixture evaluated under ASTM C1611/C1611M-21 or EN 12350-8:2019. Published data for the exact flotation threshold of this specific fiber in superplasticized concrete is limited.

    How Does the Macro-Monofilament Mechanism Compare with Steel Fiber and Fibrillated Micro-Synthetic Reinforcement?

    Steel fiber transfers stress across a crack through high axial stiffness, with an elastic modulus of approximately 200 GPa, and therefore mobilizes significant load at very small crack opening displacements. MasterFiber 230 SPA operates through a lower-modulus pullout mechanism, in which crack bridging depends on fiber-matrix bond, fiber aspect ratio, and fiber orientation. This mechanism is characterized under ASTM C1609/C1609M-19a by residual flexural strength at net deflections of L/600 and L/150, not by first-crack flexural strength alone. The polypropylene macro-monofilament does not corrode in chloride-bearing service environments, while steel fiber can form oxidation products at exposed crack surfaces. Magnetic cleanliness is another distinction: the polymer fiber does not interfere with induction-sensitive equipment or magnetic resonance imaging enclosures. In contrast to fibrillated micro-synthetic polypropylene fibers, which are typically dosed below 1.0 kg/m³ to control plastic shrinkage cracking, MasterFiber 230 SPA is intended for hardened-state post-crack reinforcement at dosages above 3.0 kg/m³. The longer discrete geometry provides anchorage across flexural cracks; however, the lower elastic modulus of 9.5 GPa limits the effective crack width that can be restrained by the fiber alone in structural elements where crack width control is governed by EN 1992-1-1:2023 or ACI 318-19.

    For slab-on-ground applications, specification of 3.0 kg/m³ to 5.0 kg/m³ is common, but the required dosage must be derived from project-specific values of residual strength at L/150, typically between 1.0 MPa and 2.0 MPa depending on the traffic load class and subgrade support. The macro-monofilament does not replace primary structural steel reinforcement in beams, columns, or load-bearing walls unless explicit project testing demonstrates equivalent ductility under ASTM C1609/C1609M-19a and the governing design code. The product is therefore positioned as a secondary reinforcement system for crack width control, impact resistance, and shrinkage restraint rather than a direct substitute for conventional bar reinforcement.

    Field batching records from central-mix concrete plants with 2.0 m³ twin-shaft compulsory mixers indicate that macro-monofilament addition is least problematic when the fibers are introduced after coarse and fine aggregate, followed by cementitious material, then water. Adding fiber before aggregate results in static charge attraction to steel mixer walls and accumulation behind the discharge gate. When fiber is added after the full water dose, hydrophobic clumping can occur at the surface film. A typical addition sequence is aggregate, fiber, cementitious material, 70 % of mixing water, chemical admixtures, and then the remaining water. After all materials are charged, the batch is mixed for a minimum of 90 seconds in a compulsory mixer or 5 minutes in a truck mixer at 12 rpm to 15 rpm. These cycle times are practical field thresholds; EN 14889-2:2006 does not prescribe a universal mixing time for macro-synthetic fibers.

    Residual Flexural Strength, Fiber Count, and Workability Boundaries

    The fiber count per unit volume is governed by the length, equivalent diameter, and specific gravity of the monofilament. The theoretical fiber count is higher than steel fiber for an equal mass dosage because of the lower density of 0.91. At dosages between 3.0 kg/m³ and 5.0 kg/m³, the fiber distribution becomes a function of aggregate packing and mixer shear. Residual strength determined by ASTM C1609/C1609M-19a generally increases with dosage up to the point where workability, compaction, and fiber balling become limiting. In conventional wet-cast concrete, dosages above 9.0 kg/m³ often produce marginal additional residual strength because the probability of fiber bundling and non-uniform dispersion increases. High-range water-reducing admixtures conforming to ASTM C494/C494M are typically required to restore placement workability at these upper dosage levels.

    Workability loss from macro-monofilament addition is commonly observed as a slump reduction of 10 mm to 20 mm at 3.0 kg/m³, depending on aggregate shape and cement paste volume. The polypropylene fiber does not absorb water, so the observed slump reduction is primarily a consequence of increased internal friction and geometric interaction with coarse aggregate. The product is not a workability-retention admixture and must be evaluated through pre-construction trial batches under the job-specific admixture package. In low-slump concrete below 25 mm, fiber dispersion becomes more dependent on mixer type and aggregate shape than on fiber aspect ratio alone.

    Comparative properties of MasterFiber 230 SPA and cold-drawn steel fiber in concrete reinforcement
    PropertyMasterFiber 230 SPACold-drawn steel fiberTest or reference basis
    Density0.91 g/cm³7.85 g/cm³ISO 1183-1:2019 / manufacturer data
    Tensile strength620 MPa1,100–1,500 MPaASTM D638-14 / ASTM A820/A820M-16
    Elastic modulus9.5 GPa200 GPaManufacturer data
    Chloride-induced corrosion responseNo electrochemical corrosion mechanismOxidation possible at exposed crack surfacesMaterial chemistry
    Magnetic responseNon-magneticFerromagneticMaterial property

    For sprayed concrete, performance is evaluated under EN 14488-5:2006 or ASTM C1550-20 for flexural toughness and energy absorption. In wet-mix sprayed concrete, the polypropylene macro-monofilament is introduced during initial batching and is carried through the delivery hose without the magnetic blockages that can affect steel fiber shotcrete. Rebound rates vary with nozzle angle, accelerator dose, and air flow. Polypropylene fibers typically reduce rebound loss compared with steel fibers because of lower density and less ballistic separation from the aggregate stream. However, the lower elastic modulus means that early-age energy absorption at large deflection may be lower than an equivalent steel fiber dosage on a mass basis. Published data for this specific configuration is limited; pre-construction spray panels are required to confirm the dosage needed for the specified energy absorption class under EN 14487-1:2005.

    When Product Selection Must Account for Alkali Exposure, High-Temperature Curing, or Magnetic Cleanliness

    Polypropylene macro fiber is resistant to alkalis in concrete pore solution at pH up to 13.5, which differentiates it from glass fiber reinforcement that may degrade under ASTM C1666/C1666M accelerated alkali exposure. The product is also non-magnetic and does not interfere with induction-sensitive equipment, making it suitable for magnetic resonance imaging enclosures, transformer foundations, and other installations requiring non-ferromagnetic reinforcement. Operational boundaries must be observed for thermal exposure. Autoclave curing or dry-heat exposure above the polymer melt temperature of approximately 162 °C leads to fiber melting and loss of reinforcement geometry. The product should not be specified where fire resistance depends on tensile reinforcement retention at temperatures above the melting point. Chloride diffusion resistance is governed by the concrete matrix, not by the fiber itself; therefore, crack width limits in EN 1992-1-1:2023 and ACI 318-19 remain the controlling durability criteria.

    For precast elements, the fiber is introduced at the central mixer before transfer to hoppers. In hollow-core slab production with very low-slump or zero-slump concrete, extrusion through narrow openings smaller than 50 mm may require a dosage reduction or the use of shorter macrofibers to prevent arching and blockages at the auger inlet. Published data for these extrusion configurations is limited, and full-scale trial batches are recommended under the actual machine speed and vibration current draw. The product is not intended to replace conventional reinforcing steel for primary flexural or shear capacity unless explicitly justified by project-specific testing under ASTM C1609/C1609M-19a and the governing design code. In self-consolidating concrete, the low density of the fiber can produce vertical segregation; therefore, the batching order and viscosity-modifying admixture dosage must be validated under ASTM C1611/C1611M-21 before production. The product's differentiation from other macro-synthetic fibers lies in its polypropylene monofilament geometry, embossed surface anchorage, and classification under Type III synthetic fiber provisions of ASTM C1116/C1116M-23.