| HS Code | 650899 |
| Product Name | MasterFiber 235 |
| Material | Polypropylene |
| Fiber Type | Extruded macro synthetic fiber |
| Fiber Form | Individual macro fibers |
| Fiber Length | 54 mm (2.13 in) |
| Equivalent Diameter | 0.90 mm (0.035 in) |
| Aspect Ratio | 60 |
| Tensile Strength | 570 MPa (82,700 psi) |
| Elastic Modulus | 9.5 GPa (1,378 ksi) |
| Melting Point | 165 °C (329 °F) |
| Specific Gravity | 0.91 |
| Water Absorption | Nil |
| Alkali Resistance | Excellent |
| Acid Resistance | Excellent |
| Salt Resistance | Excellent |
| Typical Dosage | 4.5 kg/m³ (7.6 lb/yd³) |
| Compliance | ASTM C1116 Type III, ASTM C1602, EN 14889-2 |
As an accredited MasterFiber 235 - Extruded Polypropylene Macro Fiber for Structural Reinforcement factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | MasterFiber 235 is packaged in 1 lb (0.45 kg) water-soluble bags, 40 bags per carton, and 600 lb bulk bags. |
| Container Loading (20′ FCL) | 20′ dry FCL, palletized MasterFiber 235 bags, secured and moisture-protected, maximizing payload for polypropylene macro fiber reinforcement. |
| Shipping | MasterFiber 235 is shipped as a non-hazardous, non-regulated solid in moisture-resistant bags or cartons, stacked on pallets and stretch-wrapped. Transport in covered vehicles; protect from moisture, contamination, and physical damage. Store dry, ventilated, away from sunlight, heat, and ignition sources. Handle with standard PPE; avoid dust and damaged packaging. |
| Storage | Store MasterFiber 235 in a cool, dry, well-ventilated area, away from direct sunlight, heat, sparks, and open flames. Keep in original sealed packaging, palletized off the floor to prevent moisture absorption. Avoid dust generation, incompatible chemicals, and excessive stacking. Keep containers closed when not in use, prohibit smoking, and use first-in, first-out stock rotation. Observe manufacturer shelf-life recommendations. |
| Shelf Life | Shelf life is 24 months from manufacture when stored in original unopened packaging, protected from moisture, direct sunlight, and extreme temperatures. |
MasterFiber 235, an extruded polypropylene macro fiber for structural reinforcement, is metered into precast tunnel segment mixes where the specification requires a noncorroding secondary tensile reinforcement to suppress demolding cracks, bolt-pocket spalling, and gasket-seat edge damage. Compliance for the fiber itself is assessed under EN 14889-2:2006 class II structural polymer fibers, while the finished concrete flexural response is verified through EN 14651:2005+A1:2007 notched beam testing at 150 mm × 150 mm × 550 mm and through ASTM C1609/C1609M-19 third-point loading. The recommended batching range of MasterFiber 235 is 4.0 to 6.0 kg/m³, equivalent to 0.44 to 0.66 vol% when calculated against a polypropylene solid density of 910 kg/m³. In production, a twin-shaft compulsory mixer or planetary pan mixer is used; the batching sequence introduces coarse aggregate, sand, cement, water, and superplasticizer first, and the macro fiber is added as a separate weigh-hopper charge only after initial wetting. If the fiber is dry-blended with cement or added before water, balling is observed on mixer blades and in the discharge gate, causing batch-to-batch fiber count variance. A wet mixing interval of 90 to 120 seconds after fiber addition is required at mixer rotation speeds not lower than 15 rpm to disperse the fiber through the C50/60 segment concrete. After casting, segment molds are vibrated with external form vibrators at 50 to 60 Hz, low-frequency vibration being insufficient to release entrapped air around the fiber matrix. Steam curing follows at 50 to 60 °C for 8 to 12 hours until demolding strength reaches at least 15 MPa as measured by EN 12390-3. The terminal downstream product is a reinforced concrete TBM lining segment, typically 250 to 400 mm thick, in which MasterFiber 235 functions as secondary reinforcement in combination with conventional steel bar cages; it does not replace the primary circumferential or longitudinal bending reinforcement unless project-specific ring testing under fib Model Code 2010 provisions demonstrates sufficient residual tensile capacity.
Warehouse slabs on grade are a major downstream segment in which MasterFiber 235 is batched as a replacement for a single layer of welded wire mesh, with the design objective being post-crack flexural capacity under narrow-aisle racking load cases and control of early-age shrinkage cracking. The primary compliance reference is Concrete Society Technical Report 34, fourth edition, for industrial ground floors; in North America, the material is specified as ASTM C1116/C1116M Type III synthetic macro fiber, and flexural toughness is measured under ASTM C1609/C1609M-19 at net deflections of L/600 and L/150. European projects derive residual flexural strength ratios f_R1 and f_R4 from EN 14651 at crack mouth opening displacement values of 0.5 mm and 3.5 mm. The addition rate of MasterFiber 235 in this application ranges from 3.0 to 5.0 kg/m³, corresponding to 0.33 to 0.55 vol%; the higher end of the range is selected for high-rack post loadings, heavy forklifts, or ground conditions with elevated subgrade restraint. Batching plants add the fiber through an automated conveyor or sacrificial bag system directly into the truck mixer after the conventional concrete constituents are charged; the drum is then mixed at high speed for at least 2 minutes to disperse the macro fibers. Field placement on 2,000 to 3,500 m² pour strips uses a laser screed with a target slump of 130 ± 20 mm; pump lines are specified at 65 mm ID or larger to avoid fiber bridging at hose couplings. Saw-cut contraction joints at 4.5 to 6.0 m intervals are initiated within 6 to 12 hours after finishing, and surface finish is either power-trowelled or closed with a dry-shake hardener to encapsulate fibers that may otherwise protrude under extended trowelling. The terminal finished product is a warehouse floor slab of 150 to 200 mm thickness, with surface flatness measured under ASTM E1155 FF/FL protocols. An operational boundary is that MasterFiber 235 does not eliminate the need for jointing; it reduces or replaces mesh reinforcement but does not alter the concrete shrinkage coefficient or subgrade friction restraint enough to permit unlimited joint spacing.
Shotcrete operations in tunnels, adits, and rock slopes expose MasterFiber 235 to high-velocity nozzle impingement, a production environment in which fiber rebound and orientation become the controlling variables for structural performance. The fiber is batched at 5.0 to 7.0 kg/m³ in wet-mix sprayed concrete, equivalent to 0.55 to 0.77 vol%; the upper half of this range is specified where EFNARC 1999 energy absorption class E500 or E700 is required at 25 mm central deflection in square panel tests. Compliance testing follows EN 14487-1:2005 for specification and conformity of sprayed concrete, EN 14488-3:2006 for flexural strengths of fiber-reinforced sprayed concrete, and ASTM C1550-20 round determinate panel testing, with both square and round panel methods used because aspect-ratio effects in fiber orientation are not fully captured by beam tests alone. The downstream production train consists of a piston-type wet-mix pump rated for 15 to 30 m³/h, a 75 mm ID delivery hose, and an air-assisted nozzle operated at 6 to 8 bar air pressure. The nominal maximum aggregate size is held at 8 mm or smaller to maintain pump stability and reduce rebound segregation. Spraying is performed in layers of 50 to 100 mm per pass; the nozzle is held at 0.8 to 1.2 m from the receiving surface and at an incidence angle not exceeding 30°, because field rebound measurements show a rapid increase in macro fiber loss beyond that angle. Rebound losses for wet-mix sprayed concrete with macro synthetic fiber are generally 10 to 15%, but the in-place effective fiber dosage is confirmed by cutting and testing panels rather than by assuming the batched dosage survives intact. The terminal finished product includes temporary and permanent tunnel linings, rock slope stabilization panels, and fire-protective concrete encasement where noncorroding reinforcement is required. Published data for this specific configuration is limited with respect to orientation factor variability across nozzle operators; therefore, preconstruction panel tests under ASTM C1550-20 and EN 14488-3:2006 are an unavoidable part of design validation.
Container terminal and intermodal yard pavements fall into a distinct downstream segment when the specification attempts to reduce maintenance at transverse joints under reach stacker and straddle carrier loads. MasterFiber 235 is added at 2.5 to 4.5 kg/m³ in pavement concrete with a characteristic flexural strength of 4.5 MPa at 28 days under ASTM C78/C78M; the lower end of the dosage range is used when steel dowel bars remain at construction joints, and the upper end is certified only after ASTM C1609/C1609M-19 residual strength testing demonstrates the load-deflection envelope required by the project. The applicable material standards include ASTM C1116/C1116M Type III synthetic macro fiber and EN 14889-2:2006, while pavement geometry and jointing follow ACI 330R-08 recommendations. Downstream production uses either fixed-form paving trains with a placement width of 3.5 to 5.0 m or slipform pavers; for fixed-form placement, the slump is held between 60 and 100 mm, and for slipforming, it is reduced to 25 to 50 mm. Internal poker vibrators are run at 8,000 to 12,000 vpm and spaced at 300 to 450 mm intervals to consolidate the slab without causing fiber migration to the top surface. The surface is bull-floated, textured with a wire broom or tining rake, and cured under ASTM C309-compliant curing compound applied at 0.20 to 0.25 L/m². Contraction joints, where retained, are saw-cut at 4.5 to 6.0 m spacings and to a depth of one-quarter to one-third of slab thickness within 6 to 12 hours after finishing. The terminal finished product is a jointed or jointless rigid pavement for container truck lanes, rail-mounted gantry crane runways, and reach stacker zones, typically 250 to 350 mm thick. MasterFiber 235 is not a replacement for dowels or tie bars at free edges, construction joints, or isolation joints; it provides crack-width control and residual flexural capacity within the interior slab, but edge load transfer remains a steel-furnished function.
Composite floor slabs on profiled steel decking constitute a narrower but technically documented downstream segment for extruded polypropylene macro fiber, principally as a replacement for welded wire mesh installed for plastic shrinkage crack control. The governing compliance framework is ANSI/SDI C-2017 for composite steel floor deck-slab construction, with material conformity assessed under EN 14889-2:2006 and flexural characterization performed according to ASTM C1609/C1609M-19. The typical addition rate is 3.0 to 4.0 kg/m³, approximately 0.33 to 0.44 vol%; this dosage range is intentionally lower than that used for ground-supported slabs or shotcrete because the composite slab’s primary flexural resistance is supplied by the steel deck, through-deck welding of shear studs, and conventional reinforcing bars at negative-moment regions. Downstream production involves placing normal-weight concrete with a 20 mm nominal maximum aggregate size over galvanized steel deck of 50 to 80 mm profile height, pumping through a 65 mm ID hose, and vibrating with internal vibrators at approximately 10,000 vpm to consolidate the concrete within the trapezoidal ribs. The terminal finished product is a composite floor slab of 130 to 180 mm total thickness in a steel-framed multistory building. Published data for this specific configuration is limited regarding fire resistance and long-term deflection of fiber-only crack-control composite slabs; therefore, MasterFiber 235 should not be relied upon to reduce slab thickness, shear stud count, or conventional negative-moment reinforcement unless project-specific load testing and structural evaluation under EN 1994-1-1:2004 are performed.
Competitive MasterFiber 235 - Extruded Polypropylene Macro Fiber for Structural Reinforcement prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
MasterFiber 235 is an extruded polypropylene macrofiber supplied as discrete embossed macrofilaments for structural reinforcement of concrete. The model designation identifies a macrofiber classified under EN 14889-2:2006 Class II and ASTM C1116/C1116M Type III synthetic macrofiber. In structural applications it is specified where post-crack residual strength is required from a non-corroding synthetic fiber system. Representative manufacturer-published geometry gives a nominal length of 48 mm, an equivalent diameter of approximately 0.81 mm, and a calculated aspect ratio of 59. The polymer density is 0.91 g/cm³; therefore a dosage of 4.5 kg/m³ produces a polymer volume fraction of approximately 0.5% and roughly 2×105 fibers/m³. This geometry differs from microsynthetic shrinkage-control fibers, which are typically shorter than 19 mm and are dosed below 1.0 kg/m³. The extruded macrofilament surface is embossed rather than smooth or fibrillated to increase mechanical interlock with the hardened cement paste under pullout.
Compared with hooked-end cold-drawn steel fibers, the critical difference is elastic modulus and density. Steel fiber typically has a density of 7.85 g/cm³ and an elastic modulus near 210 GPa, while MasterFiber 235 is reported at 0.91 g/cm³ and 6–10 GPa. Equal mass dosages therefore do not produce equal residual flexural strengths; substitution requires design recalculation using load-deflection values from ASTM C1609/C1609M-19 or load-CMOD values from EN 14651:2005+A1:2007. The polypropylene macrofiber is inert in alkaline concrete and does not produce chloride-induced rust staining or surface spalling. Compared with microsynthetic polypropylene fibers, MasterFiber 235 has sufficient length and dosage-dependent network density to participate in post-crack load transfer; microsynthetic products function primarily during plastic shrinkage. The product is also distinct from fibrillated polypropylene film fibers, which are slit and stretched rather than extruded as embossed macrofilaments of near-circular cross-section. Alkali-resistant glass macrofibers have higher elastic modulus but can exhibit long-term alkali-environment effects depending on glass composition; polypropylene does not undergo the same alkali-silica surface reaction in pore solution.
| Fiber class | Density | Nominal length | Tensile strength | Elastic modulus | Primary function |
|---|---|---|---|---|---|
| MasterFiber 235 extruded PP macrofiber | 0.91 g/cm³ | 48 mm | 600 MPa | 6–10 GPa | Post-crack residual strength and crack-width control |
| Hooked-end cold-drawn steel fiber | 7.85 g/cm³ | 35–60 mm | 1100–1400 MPa | 210 GPa | High-modulus post-crack reinforcement |
| Microsynthetic polypropylene fiber | 0.91 g/cm³ | 6–19 mm | 300–500 MPa | 3–5 GPa | Plastic shrinkage crack reduction |
Representative manufacturer-published physical properties are summarized in the following table. Melting occurs at approximately 160 °C; this thermal limit means the fiber is not specified for components subjected to sustained service temperatures above 80–100 °C unless the effect of polymer modulus relaxation is explicitly considered. The polypropylene matrix is resistant to alkaline pore solution, chloride ions, sulfate attack, and common concrete admixtures; water absorption is below <0.1% by mass, so pre-drying is not required for the fiber itself. Structural classification relies on residual flexural tensile strength testing of the concrete or shotcrete composite, not on the tensile strength of the raw fiber in isolation. No known chemical incompatibility exists with lignosulfonate, naphthalene, or polycarboxylate-based water reducers; however, air-entrained concrete requires re-verification of air content because macrofiber addition can disturb the air-void system.
| Parameter | Representative value | Assessment basis |
|---|---|---|
| Classification | EN 14889-2:2006 Class II, ASTM C1116/C1116M Type III synthetic macrofiber | Standards conformance |
| Length | 48 mm | Manufacturer-published |
| Equivalent diameter | 0.81 mm | Manufacturer-published |
| Aspect ratio | 59 | Calculated from length/diameter |
| Specific gravity | 0.91 g/cm³ | Manufacturer-published |
| Tensile strength | 600 MPa | Manufacturer-published |
| Elastic modulus | 6–10 GPa | Manufacturer-published |
| Melt temperature | 160 °C | Manufacturer-published |
| Water absorption | <0.1% | Manufacturer-published |
| Typical dosage range | 1.8–9.0 kg/m³ | Application-specific structural evaluation |
Dosage selection is not governed by a single property value. For slabs-on-grade and external pavements, specifications commonly set a minimum residual strength or load at a defined deflection. Under ASTM C1609/C1609M-19, beam residual load values at net deflection of L/600 and L/150 are used after peak load; under EN 14651:2005+A1:2007, residual flexural tensile strengths at crack mouth opening displacements of 0.5 mm and 2.5 mm are measured. Manufacturer-published guidance for MasterFiber 235 evaluates dosages from 1.8 kg/m³ to 9.0 kg/m³, with composite steel deck slabs commonly in the 1.8–4.5 kg/m³ range and structural slabs-on-grade requiring crack-width control predominantly tested between 4.0 kg/m³ and 6.0 kg/m³. A dosage of 4.5 kg/m³ cannot be assumed equivalent to a given area of welded wire reinforcement; conversion requires comparison of the calculated post-crack residual moment capacity from beam tests and the material partial safety factors of the governing design code. Pullout response is also more displacement-dependent than steel fiber because the embossed polymer surface does not develop the same micro-mechanical anchorage as the deformed ends of hooked steel wire.
Tunnel lining and rock-support shotcrete specifications evaluate the fiber through round-panel energy absorption rather than beam residual strength alone. In wet-mix shotcrete, MasterFiber 235 is batched at the plant or added to the truck mixer, and the mixture is delivered through a positive-displacement piston pump to the nozzle. Panel tests per ASTM C1550-20a quantify energy absorption at 25 mm central deflection; EFNARC guidance and project specifications commonly define energy absorption classes of 500 J, 700 J, and 1000 J at 25 mm. At high dosage above 8 kg/m³, wet-mix pump pressure may increase, and nozzle air volume, accelerator dose, and line diameter must be adjusted to avoid blockages. Published data for MasterFiber 235 in specific pump configurations and rock mass classes is limited; site trial panels are required because rebound and panel energy absorption vary with nozzle operator, air flow, and concrete velocity.
In precast tunnel segments and manholes, the corrosion resistance of MasterFiber 235 in sulfate- and chloride-bearing groundwater is specified where steel fiber rust staining is unacceptable and where secondary crack control is required around segment joints. The dosage is normally determined by laboratory beam tests and full-scale segment bending tests because handling loads and demolding forces can exceed service stress levels. The low electrical conductivity of the polypropylene macrofiber does not create a conductive path for stray-current corrosion, unlike steel fiber networks; however, the lower stiffness means that early-age crack-width control under lifting and stacking loads must be verified independently.
At commercial ready-mix and precast plants, MasterFiber 235 is added into a twin-shaft compulsory mixer or truck mixer after the aggregates and cement have been charged. Water-soluble or degradable bags allow direct addition without opening individual bags; the bags dissolve during wet mixing and release the fibers. Plant-scale failure modes include fiber balling when bags are discharged as a single mass into low-slump concrete or when addition occurs before coarse aggregate has wetted, and bridging in screw conveyors if mechanical dispensing is calibrated without accounting for the fiber density of 0.91 g/cm³. A mixing time extension of 30–60 seconds after fiber discharge is typical; batch records should document fiber addition time and total mixing revolutions. Slump reduction at dosages above 6 kg/m³ is controlled with polycarboxylate-based high-range water reducer, not by adding water, because an increase in water-cement ratio would reduce the residual strength used for structural verification.
Mix design integration requires attention to aggregate gradation and paste volume. The fiber length of 48 mm is compatible with common 20 mm maximum aggregate sizes, but densely packed aggregate systems with paste volume fraction below approximately 0.35 may cause fiber balling and nonuniform distribution. A minimum cementitious content of 350 kg/m³ and plastic viscosity modified with a high-range water reducer are commonly used in fiber-batched mixes, although published data for MasterFiber 235 at cementitious contents below 300 kg/m³ is limited. In pumped slab construction, a delivery hose of 65 mm diameter or larger reduces the risk of fiber plugging at elbows; field reports note that accumulations occur downstream of reducing fittings when pump pressure is cycled rapidly. In air-entrained concrete exposed to freeze-thaw cycles, the air-entraining admixture dose must be re-verified by ASTM C231/C231M pressure method before batching.
MasterFiber 235 is not a direct substitute for continuous primary reinforcement. Because the polymer elastic modulus is lower than steel, crack-width control is provided through post-crack fiber bridging rather than through high-stiffness load transfer. Design calculations must use residual strength parameters from beam or panel tests performed at the specified dosage; manufacturer-published values cannot replace project-specific trial batches when aggregate source, cement chemistry, or placement method changes. The fiber is not intended for fire-spalling protection of high-strength concrete; for that mechanism, fine-diameter polypropylene microfibers are specified. Storage should avoid prolonged direct UV exposure, and wet or damaged packaging should not be introduced into the mixer because clumped fiber bundles can reduce workability and create localized low-fiber areas in the placed concrete.