Liwei Group Co., Ltd

Products

MasterFiber 245 SPA - Polypropylene Macro Fiber for Concrete

    • Product Name: MasterFiber 245 SPA - Polypropylene Macro Fiber for Concrete
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 861896
    Material 100% Virgin Polypropylene
    Fiber Type Macro Synthetic Fiber
    Form Polypropylene Macro Fiber for Concrete
    Length 54 mm
    Equivalent Diameter 0.78 mm
    Aspect Ratio 69
    Specific Gravity 0.91
    Density 0.91 g/cm³
    Tensile Strength 570 MPa
    Young S Modulus 9.5 GPa
    Melting Point 160 °C
    Ignition Point 590 °C
    Alkali Resistance Excellent
    Acid Resistance Excellent
    Salt Resistance Excellent
    Water Absorption Nil
    Color Gray
    Packaging 600 g bags, 18 kg cartons
    Recommended Dosage 3-6 kg/m³
    Compliance ASTM C1116 Type III, ASTM D7508, EN 14889-2

    As an accredited MasterFiber 245 SPA - Polypropylene Macro Fiber for Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing MasterFiber 245 SPA is supplied in 20 kg (44 lb) moisture-resistant bags for concrete reinforcement.
    Container Loading (20′ FCL) 20′ FCL container loaded with palletized MasterFiber 245 SPA polypropylene macro fiber for concrete, securely stowed for export.
    Shipping MasterFiber 245 SPA ships as a non-hazardous, moisture-sensitive construction additive in sealed bags or pails on shrink-wrapped pallets. Transport in dry, covered trucks at ambient temperatures. Handle with standard forklifts, avoid punctures and moisture, and store indoors away from flames. Follow SDS and local regulations.
    Storage Store MasterFiber 245 SPA in a cool, dry, well-ventilated, covered area away from direct sunlight, heat, ignition sources, and moisture. Keep original bags sealed, clean, and undamaged; stack on pallets off the ground. Prevent dust generation and contamination by incompatible materials. Do not stack excessively high. Use first-in, first-out rotation. Observe good housekeeping. Follow SDS and local regulations.
    Shelf Life MasterFiber 245 SPA has a shelf life of 24 months when stored dry, unopened, in original packaging, away from moisture and sunlight.
    Application of MasterFiber 245 SPA - Polypropylene Macro Fiber for Concrete

    Does MasterFiber 245 SPA Alter Residual Flexural Capacity in Pressurized TBM Precast Segment Linings?

    Precast tunnel lining segments produced in carousel plants for pressurized TBM drives demand a fibre dosage that maintains demoulding strength while altering the post-crack behaviour measured by EN 14651:2005+A1:2007. The applicable conformity route is EN 14889-2:2006 Class II macro fibre, declared under the Construction Products Regulation (EU) No 305/2011 Annex ZA, and the fibre is typically introduced at 4.0 kg/m³ to 6.0 kg/m³ into a C50/60 concrete with a maximum aggregate size of 16 mm and a water/cement ratio not exceeding 0.40. At these addition rates, the volume fraction is approximately 0.44% to 0.66% by volume, assuming a polypropylene density of 0.91 g/cm³. The downstream production line is a high-frequency vibrated carousel system in which the fibre is dosed through an automated sack-opening station into a twin-shaft compulsory mixer with 3.0 m³ batch capacity; fibre addition must occur before water and superplasticizer reach target flow, because late addition into a high-flow self-compacting mix can produce clumping at mixer paddles. The segments are cured in a steam tunnel at 55°C to 65°C for 8 h to 10 h before demoulding, and vacuum lifting anchors are used to transfer the units. Terminal finished products include precast concrete tunnel lining rings for metro and sewerage tunnels, gasketed segmental linings with EPDM profiles, and shaft lining segments for deep access structures. The operational boundary is that macro polypropylene fibre does not replace the conventional steel cage in the segment when EN 1992-1-1 crack control is applicable, and the dosage must not exceed 6.0 kg/m³ because fibre entanglement at higher rates has been observed in high-shear pan mixers. Published data for this specific product in fibre-reinforced segment mixes is limited to EN 14651 residual strength classes and manufacturer batching guidance; no full-scale fire spalling certification should be inferred from this application description.

    In single-pour jointless industrial ground slabs for automated storage and retrieval systems, the substitution of crack-control mesh with MasterFiber 245 SPA is evaluated through ASTM C1609/C1609M-19 residual flexural strength at a net deflection of L/150 and through ASTM C1116/C1116M-23 Type III classification, while floor design follows ACI 360R-19 and the Concrete Society TR34 for pile-supported ground slabs. The addition ratio is held between 3.0 kg/m³ and 5.0 kg/m³; at 3.0 kg/m³ the slab may not reliably develop measurable post-crack residual strength when tested with a beam depth of 150 mm, whereas at 5.0 kg/m³ the power-trowel finishability window narrows unless the mix is dosed with a polycarboxylate superplasticizer to maintain a point-of-discharge slump of 120 mm to 140 mm. In a typical ready-mix production line, the fibre is discharged from a conveyor-fed automatic dispenser into a truck drum at the wet batching plant, and the drum is rotated at 14 rpm to 18 rpm for 8 min to 12 min after the last fibre dose to prevent fibre balling in a 10 mm maximum aggregate mix. The concrete is placed by truck-mounted boom pump at 40 m³/h to 60 m³/h, struck with a laser-guided screed, and finished with ride-on power trowels before curing under a spray-applied curing compound meeting ASTM C309. Terminal finished products include AGV-operated logistics floor panels, racking-supported distribution centre floors with point loads up to 50 kN per leg, and freezer slabs with positive temperature differential across the cross-section. The limitation is that macro polypropylene fibre is not a replacement for saw-cut joint planning at column grid lines; crack width control without steel reinforcement at joints requires a finite element design check and joint spacing should not be extrapolated beyond the limit specified in TR34 for the local subgrade modulus.

    When Wet-Mix Shotcrete Is Applied Robotically Against Blocky Ground After Blasting

    In underground mining headings after drill-and-blast excavation, wet-mix shotcrete requires fibre addition at the batching plant rather than at the nozzle because high-velocity air injection at the nozzle can disrupt fibre dispersion and increase rebound. The governing execution standard is EN 14487-2:2006 for sprayed concrete, with fibre conformity under EN 14889-2:2006 Class II; acceptance of post-crack performance is measured by ASTM C1609/C1609M-19 or EN 14651. MasterFiber 245 SPA is dosed at 4.0 kg/m³ to 7.0 kg/m³, corresponding to a fibre volume fraction of approximately 0.44% to 0.77%, and the upper limit is reserved for stress reorientation zones and intersection geometries where shoot-through failure can occur after 24 h. The wet-mix process is executed with a piston pump rated at 18 m³/h to 25 m³/h and a robotic manipulator with 12 m to 15 m reach; the accelerator is dosed at 2.5% to 5.0% by weight of cement through a needle valve at the nozzle, and the applied layer is built in 70 mm to 150 mm passes to reduce sloughing. The mix itself is delivered to the underground plant in a 9 m³ truck mixer with a slump of 180 mm to 220 mm at the pump hopper; compressed air is supplied at 0.4 MPa to 0.6 MPa at the nozzle and the air flow is set between 5 m³/min and 8 m³/min. Terminal finished products include shaft collar linings, ramp wall stabilization shells, temporary access drift linings, and shotcrete arches in room-and-pillar mining. An operational boundary is that fibre dosages above 7.0 kg/m³ may require a high-shear paddle mixer and a piston pump with a 100 mm or larger delivery line to avoid plugging at the reducer; published data for this specific product in wet-mix sprayed concrete with alkali-free accelerators is limited to manufacturer batching recommendations and EN 14889-2 certification, so the dosage band should be verified through a full-scale spray trial during the preconstruction phase.

    For precast mass concrete armour units cast in thick-walled steel moulds and exposed to intertidal saltwater cycles, the conflict between demoulding crack control and long-term chloride ingress below the tidal zone determines the admissible fibre dosage. For this application, MasterFiber 245 SPA is introduced at 2.5 kg/m³ to 4.5 kg/m³ in a compacted concrete with a 0.40 water/cement ratio and a 20 mm maximum aggregate; the dosage is limited to 4.5 kg/m³ because heavy external vibrators on reusable moulds can orientate macro fibres along the mould face if the mix is over-vibrated, producing a surface-rich fibre layer that complicates patch repairs. The applicable concrete specification is EN 206:2013+A2:2021 exposure classes XS3 and XF4, and the fibre conformity is EN 14889-2:2006 Class II. Production takes place in a casting yard with 40 t overhead gantry cranes and 2.5 m³ steel moulds fitted with electric external vibrators at 3,000 rpm to 4,000 rpm; each layer is compacted for 45 s to 90 s per lift, and the units are demoulded after 18 h to 24 h at a concrete temperature of 20°C to 25°C. Terminal finished products are single-layer interlocking breakwater armour units, toe berm blocks, and quay wall capping elements with a minimum mass of 2.3 t per unit. Published data for this specific configuration is limited; the dosage range above is derived from general marine concrete practice and manufacturer batching guidance rather than from long-term marine exposure tests on MasterFiber 245 SPA in interlocking armour geometry.

    Airport Apron Paving, Doweled Transverse Joints, and the FAA P-501 Compressive Strength Envelope

    For airport apron pavements subject to wide-body wheel loads and de-icer fluid exposure, MasterFiber 245 SPA serves as a secondary crack-control element in slipformed concrete where doweled joints remain the primary load-transfer mechanism. The pavement specification is aligned with FAA P-501 for Portland cement concrete pavement, and durability testing follows ASTM C666/C666M Procedure A for resistance to rapid freezing and thawing with a durability factor expected above 85% after 300 cycles. The fibre addition ratio is set at 3.0 kg/m³ to 4.5 kg/m³; this range is selected to avoid reductions in air-void system quality in mixes with a 6.0% ± 1.0% total air content and a 25 mm to 30 mm slump before the paver. The slipform paver operates at 1.0 m/min to 1.5 m/min with automatic dowel bar insertion at 450 mm spacing, and the concrete is consolidated by internal spud vibrators at 10,000 vibrations/min to 12,000 vibrations/min. The paving train is fed by a continuous shuttle conveyor from a twin-shaft mixer and the paving lane width is 4.5 m to 7.5 m; transverse joints are saw-cut at 4.5 m to 6.0 m intervals within 8 h to 12 h after placement. Terminal finished products include concrete apron panels, taxiway fillets, and runway shoulder pavement with a minimum 28-day compressive strength of 35 MPa. The operational limitation is that macro polypropylene fibre does not replace doweled load-transfer systems at transverse joints for heavy aircraft loading, and the fibre dosage must not exceed 4.5 kg/m³ in air-entrained concrete because higher doses can destabilize the spacing factor of the air-void system during slipform vibration. Published data for MasterFiber 245 SPA in airfield pavement is limited to standard concrete durability testing, not full-scale airport pavement test sections.

    Free Quote

    Competitive MasterFiber 245 SPA - Polypropylene Macro Fiber for Concrete prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber 245 SPA is identified as a polypropylene macro synthetic fiber formulated for discontinuous reinforcement of cementitious matrices. The product is classified under EN 14889-2:2006 as a Class II macro fiber, a designation requiring an equivalent diameter equal to or greater than 0.3 mm and distinguishing the material from Class I microfibers that mitigate plastic shrinkage cracking rather than post-crack load transfer. The polypropylene composition yields a specific gravity of approximately 0.91 g/cm³, a melt temperature in the range of 160–170°C, and an elastic modulus commonly cited between 3.5 and 6.0 GPa for this fiber class. Fiber length specifications for MasterFiber 245 SPA vary by regional production configuration, with published values spanning 38–54 mm. Tensile strength for macro polypropylene fibers of this category typically falls within 350–650 MPa; product-specific certification data should be obtained from the current manufacturer technical datasheet, as published figures for this exact grade remain subject to batch-level and regional variation.

    How Does MasterFiber 245 SPA Differ from Hooked-End Steel Fibers in Post-Crack Behaviour?

    The primary performance distinction between MasterFiber 245 SPA and hooked-end steel fibers arises from the fundamental difference in elastic modulus. Steel fibers exhibit a modulus of elasticity of approximately 200 GPa, whereas macro polypropylene fibers fall within the 3.5–6.0 GPa range. This disparity produces divergent mechanisms of post-crack load transfer. Steel fibers resist crack opening through direct elastic stiffness, contributing to a steep load–crack mouth opening displacement (CMOD) response in the serviceability limit state. MasterFiber 245 SPA, by contrast, mobilizes frictional pull-out resistance along the fiber–matrix interface, with the embossed or crimped surface geometry governing bond strength. Under testing conforming to EN 14651 (test method for metallic fiber reinforced concrete, adapted for synthetic fibers), steel fibers typically demonstrate residual flexural tensile strengths at CMOD values of 0.5 mm and 3.5 mm that are achievable at lower dosage rates than synthetic counterparts. However, the polypropylene macro fiber offers resistance to chloride-induced corrosion—an operational boundary that limits steel fiber use in marine exposure, de-icing salt environments, and certain industrial floor applications where surface oxidation would compromise aesthetics or long-term durability. The lower density of polypropylene (0.91 g/cm³ versus 7.85 g/cm³ for steel) means that equal fiber volume fractions translate to a substantially lower weight addition per cubic meter, which has implications for batching logistics and mixer wear rates on production scales exceeding 50 m³/h.

    Dispersion behaviour in high-shear concrete mixers constitutes the controlling variable for achieving homogeneous fiber distribution. MasterFiber 245 SPA is introduced at the batching stage, either directly into the aggregate stream during weighing or into the mixer after the addition of coarse aggregate. Premature introduction into the cementitious fines—before coarse aggregate is present—has been observed on production lines to lead to fiber agglomeration, a failure mode characterized by visible clumping at the mixer discharge and non-uniform fiber counts in cube samples. The recommended mixing duration following fiber addition is 5–7 minutes at a mixer rotational speed producing a peripheral velocity of approximately 1.5–2.0 m/s, based on pan mixer configurations commonly deployed in precast operations. A sequential batching protocol is preferred: aggregate and fibers are charged first, mixed for 60–90 seconds to initiate mechanical dispersion, followed by cement and water. This sequence reduces the tendency of fibers to coat the mixer blades, a phenomenon documented on twin-shaft mixers with L/D ratios exceeding 1.0 where fiber accumulation on the paddle assembly has necessitated downtime for manual clearing at intervals of 300–400 batches. Slump reduction attributable to fiber addition must be compensated through superplasticizer dosage adjustment, with field observations indicating a slump decrease of 20–40 mm at fiber dosages of 4–6 kg/m³ in concrete with a water–cement ratio of 0.45.

    Residual Flexural Strength Parameters Measured Under EN 14651 Notched Beam Testing

    Characterization of MasterFiber 245 SPA for structural contribution requires evaluation of the load–CMOD relationship using three-point bending on notched beams per EN 14651. The test configuration employs a 150 mm × 150 mm × 550 mm beam with a 25 mm notch depth, loaded at a CMOD rate of 0.05 mm/min for crack initiation control and 0.2 mm/min beyond the proportionality limit. Residual flexural tensile strengths are reported at CMOD values of 0.5 mm (fR1) and 3.5 mm (fR3), with the ratio fR3/fR1 serving as an indicator of post-crack ductility. For macro polypropylene fibers at dosages of 5–8 kg/m³, published test data from comparable Class II synthetic fibers indicate fR1 values typically in the range of 1.5–4.0 MPa and fR3 values between 1.0–3.5 MPa, with the residual values strongly dependent on concrete matrix strength class, fiber aspect ratio, and mixing homogeneity. Published data for MasterFiber 245 SPA specifically is limited in peer-reviewed literature; the ranges cited above derive from Class II macro polypropylene fibers with equivalent diameters of 0.6–0.9 mm and aspect ratios of 60–80, which represent the closest comparable product category. Design guidance such as fib Model Code 2010 permits the incorporation of residual flexural parameters from synthetic fiber concrete into the design of statically indeterminate slabs, provided that the post-crack softening behaviour is explicitly accounted for in the constitutive model.

    Property / Parameter MasterFiber 245 SPA (Class II Macro PP) Hooked-End Steel Fiber Class I Micro PP Fiber
    Base material Virgin polypropylene, monofilament Cold-drawn low-carbon steel wire Virgin polypropylene, fibrillated or monofilament
    Equivalent diameter ≥ 0.3 mm (typically 0.6–0.9 mm) 0.5–1.0 mm < 0.3 mm (typically 0.018–0.030 mm)
    Length 38–54 mm 30–60 mm 6–19 mm
    Density 0.91 g/cm³ 7.85 g/cm³ 0.91 g/cm³
    Tensile strength 350–650 MPa 1000–1500 MPa 300–500 MPa
    Elastic modulus 3.5–6.0 GPa 200 GPa 3.5–7.0 GPa
    Classification standard EN 14889-2:2006 (Class II) EN 14889-1:2006 EN 14889-2:2006 (Class I)
    Primary function Post-crack load transfer; moderate structural contribution Post-crack load transfer; structural reinforcement Plastic shrinkage crack control; fire spalling mitigation
    Corrosion susceptibility None in alkaline concrete environment Susceptible to surface oxidation and chloride-induced corrosion None
    Typical dosage range 3–9 kg/m³ 20–40 kg/m³ 0.6–1.5 kg/m³

    Shotcrete Support in Tunnel Linings and Rock Stabilization

    The substitution of welded wire mesh with macro synthetic fibers in wet-mix shotcrete applications has been implemented in tunnel primary linings where the groundwater chemistry presents corrosion risk to conventional steel reinforcement. MasterFiber 245 SPA is batched into the wet-mix shotcrete at dosages typically in the range of 4–7 kg/m³, with the fiber-reinforced shotcrete then pneumatically applied using equipment operating at air pressures of 4–7 bar and concrete output rates of 10–20 m³/h. The rebound behaviour of macro polypropylene fibers differs from steel fibers in that the lower density (0.91 g/cm³) results in a lower ballistic mass per fiber, which reduces the kinetic energy transfer at the substrate surface. Field monitoring on tunnel projects has recorded total rebound values of 8–15% for macro polypropylene fiber shotcrete, compared with 5–20% reported for steel fiber shotcrete depending on application angle and nozzle distance. Energy absorption capacity, evaluated through panel testing under EN 14488-5, is the controlling performance parameter for rock burst and dynamic loading scenarios. Panels reinforced with macro polypropylene fibers at 6 kg/m³ have demonstrated energy absorption values in the range of 400–700 J when tested at a panel thickness of 100 mm, although published data for MasterFiber 245 SPA specifically in this configuration is limited and the cited range derives from comparable Class II synthetic macro fibers.

    Joint-free slab construction on grade represents a further application context where MasterFiber 245 SPA modifies the load-transfer mechanism at induced contraction joints. In conventional steel fiber slab design, the residual flexural strength governs the permissible joint spacing and slab thickness through yield line analysis. For macro polypropylene fiber slabs, the lower elastic modulus requires that the reduced post-crack capacity be compensated through slab thickness increases or reduced joint spacing, with design calculations performed using the residual flexural strength values obtained from EN 14651. Saw-cut induction of contraction joints is performed at intervals of 24–72 hours after placement, with the fiber reinforcement bridging the crack that subsequently forms beneath the saw-cut plane. The load-transfer efficiency across sawn joints in macro polypropylene fiber slabs has been measured using falling weight deflectometry on industrial pavements, with published data indicating joint load-transfer efficiencies of 70–85% at fiber dosages of 5 kg/m³ in slabs of 150 mm thickness on compacted granular subbase. This compares with load-transfer efficiencies above 95% typically achieved with dowelled joints, establishing a clear performance hierarchy that must be reflected in the structural design assumptions.

    When Replacing Welded Wire Mesh in Precast Concrete Elements

    The use of MasterFiber 245 SPA as a partial or complete replacement for welded wire mesh in precast elements introduces a distinct shift in the production workflow, governed by the elimination of mesh placement labour and the associated crane time. Precast operations producing manhole risers, culvert sections, and retaining wall panels have converted to macro fiber reinforcement where the structural demand permits, with dosage rates adjusted based on the equivalent flexural performance required. The production sequence in a carousel precast plant is modified such that fibers are dosed directly into the planetary or pan mixer at the batching station, eliminating the mesh placement station on the production line. Cycle time reductions of 4–8 minutes per mold have been reported in precast facilities producing elements with mesh placement times previously occupying 30–40% of the total mold preparation cycle. However, the operational boundary condition requires that the precast element not be subjected to concentrated point loads or handling stresses that exceed the residual tensile capacity of the fiber-reinforced concrete during demolding and transport. Lifting anchor pull-out capacity, governed by the concrete cone failure mechanism, must be verified through pull-out testing per EN 1992-4, as the fiber reinforcement does not provide the same crack-bridging capacity around anchors as continuous bar or mesh reinforcement.

    Alkali resistance in the cementitious pore solution represents a non-negotiable performance criterion for any polymer fiber in concrete service. Polypropylene, being a saturated hydrocarbon polymer, demonstrates negligible hydrolytic degradation in the high-pH environment (pH 12.5–13.5) of concrete pore water. Long-term durability data from accelerated aging testing at 60°C in saturated calcium hydroxide solution, conducted over 12 months, show no statistically significant reduction in tensile strength for polypropylene fibers of this class. This is in contrast to polyester (PET) fibers, which undergo alkaline hydrolysis under the same conditions, and glass fibers, which require zirconia content above 16% to achieve acceptable alkali resistance per EN 15422. The oxidation resistance of polypropylene fibers is, however, limited at elevated service temperatures. Continuous exposure exceeding 80°C accelerates thermo-oxidative degradation of the polymer backbone, with the addition of antioxidant packages in the fiber formulation extending but not eliminating this temperature boundary. For concrete elements in continuous service above 80°C, alternative reinforcement strategies are required. Fire spalling performance of concrete containing MasterFiber 245 SPA may differ from that of concrete containing Class I microfibers, as the larger diameter of macro fibers reduces the number of fiber channels available for vapour pressure relief per unit volume; designs requiring enhanced fire resistance should incorporate microfibers at 1–2 kg/m³ in addition to the macro fiber dosage, or follow the prescriptive guidance of EN 1992-1-2 with specific spalling test validation.

    Batch-to-batch variance in fiber geometry and surface treatment represents a processing variable that precast and ready-mix operations must monitor through incoming material inspection. Fiber length distribution, measured on a sample of 100 fibers per production lot, should conform to the manufacturer's declared tolerance, typically ±10% of the nominal length. Equivalent diameter verification is performed using micrometer measurement on flattened fiber cross-sections or by calculating the average of six diameter readings per fiber at 60° rotational intervals. Water absorption of polypropylene fibers is negligible (< 0.1% by mass per ISO 62), which eliminates the need for fiber pre-drying prior to batching—an operational contrast with natural fibers or certain PVA fibers that exhibit hygroscopic behaviour. Storage requirements for MasterFiber 245 SPA specify protection from direct UV exposure during extended outdoor storage periods, as ultraviolet radiation degrades the antioxidant package and embrittles the polymer surface over cumulative exposure exceeding 6–12 months, depending on latitude and solar intensity. The packaging configuration—degradable paper bags designed for direct addition to the mixer—eliminates the labour associated with fiber bag opening and reduces the risk of plastic packaging fragments contaminating the concrete, a quality control concern documented in plants where polyethylene bag remnants have been identified in hardened concrete core samples.