Liwei Group Co., Ltd

Products

MasterFiber MAC 2200 CB - Chemically Enhanced Synthetic Macrofiber (Polypropylene)

    • Product Name: MasterFiber MAC 2200 CB - Chemically Enhanced Synthetic Macrofiber (Polypropylene)
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 696290
    Productname MasterFiber MAC 2200 CB - Chemically Enhanced Synthetic Macrofiber (Polypropylene)
    Producttype Chemically enhanced synthetic macrofiber
    Basematerial Polypropylene
    Fiberlength 54 mm (2.1 in)
    Fiberdiameter 0.66 mm (0.026 in)
    Aspectratio 82
    Specificgravity 0.91
    Tensilestrength 620 MPa (90,000 psi)
    Youngsmodulus 9.65 GPa (1,400,000 psi)
    Meltingpoint 160 °C (320 °F)
    Waterabsorption Nil
    Alkaliresistance Excellent
    Acidresistance Excellent
    Electricalconductivity Low
    Thermalconductivity Low
    Color Gray
    Form Monofilament
    Dosagerate 3 to 9 kg/m³ (5 to 15 lb/yd³)
    Standardcompliance ASTM C1116 Type III; EN 14889-2 Class II

    As an accredited MasterFiber MAC 2200 CB - Chemically Enhanced Synthetic Macrofiber (Polypropylene) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing MasterFiber MAC 2200 CB is supplied in 20 lb (9.1 kg) polyethylene bags, palletized for shipment and storage.
    Container Loading (20′ FCL) Container Loading (20′ FCL): MasterFiber MAC 2200 CB chemically enhanced synthetic polypropylene macrofiber, palletized, loaded dry and secure in a 20-foot container.
    Shipping MasterFiber MAC 2200 CB ships as a non-hazardous, moisture-sensitive polypropylene macrofiber in sealed bags or boxes, palletized and stretch-wrapped. Transport in clean, dry vehicles; store indoors away from sunlight and moisture. No special DOT/IMDG/IATA restrictions apply. Handle with standard PPE and avoid package damage.
    Storage Always store MasterFiber MAC 2200 CB in original, unopened packaging in a cool, dry, well-ventilated area. Keep away from moisture, direct sunlight, heat, flames, and ignition sources. Protect from contamination and physical damage. Keep pallets off damp floors and avoid excessive stacking. Reseal opened bags to prevent moisture uptake. Shelf life is typically indefinite when stored properly under these conditions.
    Shelf Life 12 months from date of manufacture when stored in original, unopened packaging in a dry, protected area at moderate temperatures.
    Application of MasterFiber MAC 2200 CB - Chemically Enhanced Synthetic Macrofiber (Polypropylene)

    In slab-on-grade construction for distribution centres and logistics terminals, MasterFiber MAC 2200 CB is charged at the batch plant after coarse aggregate and before final mixing water, at addition rates from 3.0 kg/m³ to 5.0 kg/m³. The batching sequence prevents fiber balling in a twin-shaft compulsory mixer with a wet mixing time of 5 minutes to 7 minutes after fiber introduction. A water-reducing admixture conforming to ASTM C494/C494M-19 Type A or Type F is used to maintain a slump of 150 mm ± 20 mm at the paver, because the chemically enhanced polypropylene surface increases paste demand by 5 kg/m³ to 10 kg/m³ of cementitious paste. Pumping through a 32 m boom pump with 125 mm line does not require changes to air entrainment, provided air content measured per ASTM C231/C231M-22 is held at 2.0% to 4.0% for interior slabs not exposed to freeze-thaw cycling. The terminal floor is typically a rack-supported slab with joint spacing limited to 4.5 m by saw-cutting within 8 hours to 12 hours of final finishing under ACI 360R-10 guidance. Residual flexural performance is verified after 28 days by ASTM C1609/C1609M-19, using third-point loading on 150 mm × 150 mm × 500 mm beams. At 3.0 kg/m³, the fiber contribution is usually limited to crack-width control after first crack; at 5.0 kg/m³, the specimen typically maintains rising load-carrying capacity past a deflection limit of L/600. Fiber distribution is checked by washing out 0.01 m³ samples at the discharge chute and inspecting for clumps larger than 25 mm, which must not exceed 1 clump per 0.5 m³ of placed concrete. When finished with a ride-on trowel, blade angle is reduced by 10° to 15° compared with plain concrete to avoid tearing surface fibers. ACI 302.1R-15 recommends a membrane-forming curing compound conforming to ASTM C309 applied at 0.20 L/m², and wet curing is extended by 24 hours when ambient relative humidity drops below 40%.

    What Changes in Demoulding Cycle Times when Macrofiber Replaces Steel Mesh in Precast Panels?

    Non-structural precast elements such as utility vaults, retaining wall panels, box culvert covers, and slatted flooring are cast with MasterFiber MAC 2200 CB at 4.0 kg/m³ to 6.0 kg/m³ to eliminate mesh cutting and fixing labour. The fiber is introduced into a planetary counter-current mixer after aggregate and cement are dry-blended for 30 seconds; the remaining mixing time is 90 seconds to 120 seconds at high speed after fiber addition. Formwork is filled using external vibrators operating at 12,000 vpm to 16,000 vpm, applied in 10-second intervals to avoid fiber orientation collapse near vertical faces. Stripping time is governed by the minimum demoulding strength of 10 MPa to 12 MPa measured by rebound hammer and correlated to cylinders per ASTM C39/C39M-21. Because macrofiber does not provide the same early-age flexural capacity as steel reinforcement, precast units with slenderness ratios above 20 still require lifting beam inserts and cannot rely on fiber alone during demoulding. The surface finish of vertical precast elements is checked after stripping for visible fiber clumps, and any clump exceeding 15 mm in length is rejected under the precaster’s own visual acceptance protocol. Curing is performed under a thermostatically controlled steam regime at 60 °C for 8 hours, followed by 3 days of ambient air curing before load transfer.

    Verification ParameterReferenced StandardAcceptance Boundary
    Polymer macrofiber classificationASTM C1116/C1116M-23Type III synthetic fiber
    European fiber conformityEN 14889-2:2006CE marking and manufacturer declaration
    Flexural performanceASTM C1609/C1609M-19Residual strength at L/600 reported
    Air contentASTM C231/C231M-222.0% to 4.0%
    Compressive strengthASTM C39/C39M-21No more than 5% reduction versus control at 28 days
    Slump after fiber additionASTM C143/C143M-20150 mm ± 25 mm

    Tunnel Lining Shotcrete and Rebound Behaviour in Wet-Mix Application

    Wet-mix sprayed concrete for permanent rock support in non-aggressive ground is produced with MasterFiber MAC 2200 CB at 7.0 kg/m³ to 9.0 kg/m³ to reduce plastic shrinkage and control early-age cracking around rock bolts and lattice girders. The concrete is batched at a slump of 180 mm to 200 mm, stabilised with a polycarboxylate ether superplasticiser conforming to EN 934-2:2009, and transported within 45 minutes to the shotcrete robot. The fiber is added at the batch plant, not at the nozzle, because post-nozzle fiber injection can disrupt the accelerator stream and create fiber-rich pockets in the sprayed layer. Hydration control is achieved with an alkali-free liquid accelerator dosed at 3% to 5% by cement weight, adjusted at the pump to maintain early strength of 1 MPa at 6 hours measured by needle penetration per EN 14488-2:2006. Rebound is controlled by nozzle distance of 1.0 m to 1.5 m, air flow of 5 m³/min to 8 m³/min, and wall overspray thickness removal before final layer application. Published data for rebound reduction in this specific fiber configuration is limited; therefore rebound acceptance must be established through on-site panel tests rather than transferred from steel fiber shotcrete records. The terminal sprayed lining is tested for flexural toughness using ASTM C1550-20 round panel tests on 75 mm thick specimens sprayed in the same orientation as the tunnel lining. At 7.0 kg/m³, the panel energy absorption at 40 mm central deflection is typically higher than early-age plastic shrinkage control levels but lower than steel fiber shotcrete at equivalent dosage; designers therefore maintain the steel lattice girder system for structural capacity. Fiber dispersion is verified at the nozzle by washing 10 L samples through a 4.75 mm sieve and counting retained fiber clumps, with a rejection limit of 3 clumps per 10 L. The concrete pressure at the nozzle is maintained between 0.5 MPa and 0.8 MPa to prevent segregation. Overspray containing macrofiber is not recirculated into the batch because variable fiber content cannot be homogenised within the wagon mixer.

    If Composite Metal Deck Construction Limits Finishing Time, the Fiber Addition Sequence Becomes More Sensitive than Slab Thickness

    Slabs cast on galvanised steel deck in composite floor systems are dosed with MasterFiber MAC 2200 CB at 1.8 kg/m³ to 3.0 kg/m³ to replace light-gauge welded wire reinforcement for crack control in negative moment regions above girders. The placement is pumped through a 50 mm rubber hose with concrete slump maintained at 140 mm ± 20 mm per ASTM C143/C143M-20. Because the fiber is hydrophobic and chemically enhanced, it disperses under the high shear of a truck-mounted pump without floating to the troweled surface if the finisher waits 15 minutes to 20 minutes after strike-off before first floating. In this application, the use of a bull float is limited to a single pass; repeated floating can draw fibers toward the top 6 mm and produce a hairy surface after burnishing. The terminal floor is a composite metal deck slab with a cover slab thickness of 65 mm to 90 mm over the deck ribs; flexural residual strength is tested by ASTM C1399/C1399M-10 at a net deflection of L/300, not ASTM C1609, because section depth is too small for beam testing. Published data for this specific composite section is limited, so qualification testing must use the specified deck profile and concrete cover rather than flat-slab specimens. Bond between the concrete cover and the steel deck is verified by visual inspection of the underside after deck removal for honeycombing, and the fiber content is rechecked after every 40 m³ of placement to ensure that pump pressure has not caused fiber accumulative loss in the hopper screen.

    Unbonded concrete overlays for bus lanes and container yards receive MasterFiber MAC 2200 CB at 4.0 kg/m³ to 6.0 kg/m³ as a crack-width control agent in 120 mm to 180 mm thick slabs placed over a polyethylene separation layer. The concrete is specified with a maximum aggregate size of 10 mm to 14 mm, a water-cement ratio not exceeding 0.45, and a synthetic macrofiber that passes a boiling test in water at 100 °C for 1 hour with no visible degradation. Fiber addition at these rates requires a central mixer, not a transit mixer alone, because the short mixing period in a ready-mix truck cannot fully open the fiber bundles. The surface is textured longitudinally with a broom or tined float to produce a macrotexture of 0.5 mm to 0.8 mm without pulling fibers from the matrix. Joints are cut at intervals of 6.0 m, and the fiber content is verified by washout of a 20 kg fresh concrete sample against the mix design after every 50 m³ of placement. Compressive strength acceptance is based on ASTM C39/C39M-21 at 28 days and flexural performance on ASTM C1609/C1609M-19 beams sawn from the same batch. When ambient temperature exceeds 30 °C, the concrete is shaded and the surface is fog-sprayed before finishing to prevent early plastic shrinkage cracks that the macrofiber cannot fully close once crack widths exceed 0.5 mm.

    Laser Screed Placement Disturbs Surface Fibers More than a Truss Screed in Very-Narrow-Aisle Slabs

    Logistics buildings with very-narrow-aisle racking impose tight floor flatness and levelness requirements, typically FF 50 and FL 35 under ASTM E1155-20, and MasterFiber MAC 2200 CB is included at 5.0 kg/m³ to 7.0 kg/m³ to maintain crack control without mesh that interferes with laser screed operation. The concrete is placed at a slump of 160 mm ± 20 mm and struck off with a laser-guided paver capable of maintaining 3 mm elevation tolerance over 3 m. Fiber lumps are screened by a 50 mm vibrating grate at the pump hopper to prevent blocking the paver auger. Finishing uses a ride-on power trowel with pan floats, and the first floating pass is delayed until bleed water disappears from the surface; early troweling folds surface fibers and creates visible orange peel texture. The terminal slab is left without wet curing for more than 24 hours if the relative humidity is below 50%, and a curing compound conforming to ASTM C309 is applied at 0.15 L/m² to 0.20 L/m² within 2 hours after final troweling. Residual strength is measured by ASTM C1609/C1609M-19 using beams cast on site because saw-cut samples from a completed floor cannot provide the required dimensional tolerance. Joint filling is delayed until the moisture vapor emission rate measured per ASTM F2170-22 is below 3 lb/1,000 ft²/24 h, preventing trapped moisture from softening the filler material in high-rack wheel paths.

    Precast drainage components such as catch basins, manhole risers, and culvert invert sections are cast with MasterFiber MAC 2200 CB at 4.0 kg/m³ to 6.0 kg/m³ to reduce cracking during form stripping and transport to the site. The concrete is mixed in a twin-shaft plant mixer for 4 minutes after fiber addition, and the fibers are introduced through the aggregate weigh hopper to disperse them before water contact. External form vibrators are operated at 9,000 vpm to 12,000 vpm for 5 seconds per position to avoid forming fiber orientation planes at the form face. The terminal element is cured under steam at 60 °C for 8 hours and then air-cured for 3 days before hydrostatic testing. The fiber does not replace the reinforcing cage required for earth loads; it is used as a secondary crack-control agent at zones of high stress concentration around lifting anchors. Compliance for stormwater contact is assessed through a migration test under EN 12873-1:2014 where required; published data for potable water contact in this specific fiber configuration is limited and must be confirmed before use in drinking water reservoirs. The precaster verifies fiber dispersion by splitting a 150 mm cube from the first batch each day and counting visible clumps on the fractured face, with a production limit of 2 clumps per 0.02 m² of fractured surface.

    Free Quote

    Competitive MasterFiber MAC 2200 CB - Chemically Enhanced Synthetic Macrofiber (Polypropylene) prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber MAC 2200 CB is a chemically enhanced synthetic macrofiber manufactured from polypropylene. The product designation includes the MAC 2200 CB suffix, which identifies the macrofiber geometry and the chemically enhanced surface treatment. Manufacturer-published nominal data list a fiber length of 54 mm, a specific gravity of 0.91 when tested under ASTM D792-20, and a filament tensile strength of 620 MPa when tested under ASTM D2256/D2256M-21. The product is supplied in collated bundles that are intended to separate into individual monofilaments during concrete mixing. Typical addition rates range from 1.8 kg/m³ to 7.5 kg/m³ in concrete, mortar, and wet-mix shotcrete. Under EN 14889-2:2006, the product is classified as a polymer macrofiber for structural use in concrete, mortar, and grout. The intended function is post-first-crack residual load capacity and crack-width control, not continuous primary reinforcement. Independent published data for this specific product configuration is limited; batching and flexural performance should therefore be verified with project-specific mix designs.

    Applicable standards for product verification and performance testing
    Standard designationTest scopeUse boundary
    EN 14889-2:2006Polymer fibers for structural concreteCE marking basis; macrofiber classification
    ASTM C1116/C1116M-23Fiber-reinforced concrete and shotcreteProduct acceptability
    ASTM C1609/C1609M-19aFlexural performance of fiber-reinforced concreteResidual strength at net deflection L/600 and L/150
    ASTM C1399/C1399M-14Average residual strength of fiber-reinforced concreteAlternative beam method
    ASTM C1550-20Round panel flexural toughnessShotcrete and slab applications
    ASTM D792-20Specific gravity of polymerMaterial identity
    ASTM D2256/D2256M-21Tensile properties of yarns and fibersFilament tensile strength

    What Flexural Residual Strength Does ASTM C1609/C1609M-19a Capture for Macrofiber Concrete?

    Flexural performance is typically evaluated under ASTM C1609/C1609M-19a using a closed-loop servo-hydraulic testing machine and a 150 mm × 150 mm × 500 mm beam in third-point loading. The method records first-peak strength and residual strengths at net deflections of L/600 and L/150, designated fD600 and fD150. For synthetic macrofibers of this class at dosages of 3.0–6.0 kg/m³, reported residual strength values commonly fall between 1.0 MPa and 2.5 MPa for fD600; however, published data for this specific chemically enhanced product configuration is limited. The measured value depends on matrix compressive strength, aggregate type, mixing intensity, fiber distribution, and the presence of water-reducing admixtures. Under EN 14651:2005+A1:2007, the corresponding limit of proportionality and residual flexural tensile strengths fR,1 and fR,4 are measured on a 150 mm × 150 mm × 550 mm notched beam. Comparative specification for a given project should use one test method consistently, because the notch geometry and crack mouth opening displacement control can shift residual strength values by more than 20%.

    Batching line observations on a twin-shaft compulsory mixer with a 4.0 m³ discharge volume indicate that the collated fiber bundles are best added after aggregate and cement charge and before water. A wet addition sequence through the aggregate conveyor can reduce fiber balling when the coarse aggregate moisture content exceeds 2.0%. In a 3 m³ pan mixer, addition at rates above 5 kg/m³ without extending wet mixing by 120 seconds produced visible fiber clumps along the mixer blade root; a cyclone pre-dispenser or a variable-speed conveyor feed reduces this defect. Slump loss after fiber addition is matrix-dependent. When a 0.42 w/c concrete with a polycarboxylate ether superplasticizer at 0.6% by mass of cement received 4.0 kg/m³ of macrofiber, the measured slump by ASTM C143/C143M-20 dropped from 180 mm to 140 mm in trial batching. Published data for this specific product configuration is limited, and the response must be confirmed for the actual cement type, supplementary cementitious material content, and superplasticizer chemistry. Fiber balls remaining after normal mixing should be detected by a slump cone spread inspection, not by visual sidewall observation alone.

    Chemical Enhancement and Cementitious Matrix Interaction

    Chemical enhancement in polypropylene macrofibers is intended to increase surface polarity and interfacial friction with the hydrating cement paste. Polypropylene without surface modification has a low surface energy, typically in the range of 29–31 mN/m by contact angle methods, which limits wetting and pull-out resistance. The chemically enhanced surface of MasterFiber MAC 2200 CB is supplied as a proprietary additive package; independent disclosure of the exact functional chemistry is not available. Scanning electron microscopy of similar enhanced macrofibers shows increased cement hydration product adhesion after 28 days of moist curing. Pull-out resistance is not measured directly by standard beam tests but influences the residual strength values obtained under ASTM C1609 and EN 14651. At addition rates above 4.0 kg/m³, the fiber-matrix bond rather than fiber tensile strength often governs post-crack load capacity, particularly in high-strength concrete with compressive strength above 50 MPa.

    When Steel Wire Mesh Is Replaced in Slab-on-Ground Construction

    When MasterFiber MAC 2200 CB is considered as a replacement for welded wire mesh in slab-on-ground construction, the design function is crack-width control and shrinkage restraint, not structural load transfer across construction joints. The substitution is evaluated under ASTM C1609 or ASTM C1550-20, and the specified dosage is commonly 3.0–7.5 kg/m³. Steel wire mesh at 100 mm × 100 mm spacing provides a localized reinforcement cross-section; the macrofiber distributes randomly in three dimensions, which reduces the risk of misplacement and corrosion. However, the elastic modulus of polypropylene is approximately 6–10 GPa, compared with approximately 200 GPa for steel, so the post-crack stiffness at equal macrofiber dosage is lower. Published data for this specific product configuration is limited; structural design should not use macrofiber alone for moment capacity unless project-specific load-deflection testing and engineering review are conducted under the applicable building code. Placement in exterior slabs with deicing salts does not introduce the chloride-induced corrosion mechanisms associated with steel reinforcement, but the concrete chemistry and cover requirements remain unchanged.

    Steel Fibers, Glass Fibers, and Untreated Polypropylene Macrofibers Differ in Density, Modulus, and Corrosion Response

    Steel fiber reinforcement is governed by ASTM A820/A820M-22 and EN 14889-1:2006. Steel fibers with tensile strengths of 1000–1200 MPa and a density of 7.85 g/cm³ provide higher residual flexural strength per kilogram of fiber and higher first-crack toughness. MasterFiber MAC 2200 CB has a lower density of 0.91 g/cm³ and lower tensile modulus, which reduces placement weight but requires a higher volume fraction to achieve comparable energy absorption at large deflections. Glass fiber reinforcement, particularly alkali-resistant glass in compliance with ASTM C1666/C1666M-21, offers high tensile strength and modulus but can be susceptible to alkaline hydrolysis if non-alkali-resistant grades are misapplied. Polypropylene macrofiber without chemical enhancement relies solely on mechanical anchoring and surface roughness. The chemically enhanced grade is intended to improve interfacial bond with the cementitious matrix, reducing the pull-out displacement at a given load. In wet-mix shotcrete, the product is evaluated using ASTM C1436/C1436M-17 for sampling and ASTM C1550-20 for flexural toughness; rebound behavior differs from steel fibers because of lower particle mass. Independent comparative data for this specific product configuration is limited, so product substitution should be validated through side-by-side beam or panel tests using the same mix and curing regime.

    At relative humidity greater than 60%, bags should remain sealed until addition to prevent surface moisture uptake and electrostatic clumping. The product is not intended as primary flexural reinforcement in beams, columns, or suspended slabs. It does not replace structural steel in load-bearing concrete elements. The chemically enhanced surface does not eliminate the need for proper curing. Published data for this specific product configuration is limited, so trial batching under representative production conditions remains mandatory.