Liwei Group Co., Ltd

Products

SikaFiber 155 - Embossed Macro Fiber for Concrete and Shotcrete

    • Product Name: SikaFiber 155 - Embossed Macro Fiber for Concrete and Shotcrete
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 961713
    Productname SikaFiber 155 - Embossed Macro Fiber for Concrete and Shotcrete
    Material Polypropylene
    Fibertype Embossed macro synthetic fiber
    Form Monofilament bundles
    Colour Natural
    Length 55 mm
    Diameter 0.8 mm
    Density 0.91 g/cm³
    Tensilestrength 550 MPa
    Elasticmodulus 7 GPa
    Meltingpoint 165 °C
    Alkaliresistance High
    Waterabsorption Nil
    Chemicalresistance Good
    Electricalconductivity None
    Dosageconcrete 3-9 kg/m³
    Dosageshotcrete 4-8 kg/m³
    Primaryapplication Concrete and shotcrete
    Standards EN 14889-2, ASTM C1116

    As an accredited SikaFiber 155 - Embossed Macro Fiber for Concrete and Shotcrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SikaFiber 155 comes in 5 kg moisture-resistant bags, suitable for concrete and shotcrete, ensuring easy storage, handling, and accurate dosing.
    Container Loading (20′ FCL) 20′ FCL: SikaFiber 155 embossed macro fiber for concrete and shotcrete, palletized in bags, dry container, secured for ocean transport.
    Shipping SikaFiber 155 is a non-hazardous, non-regulated material, typically palletized in moisture-resistant bags. No special transport labels, placards, or UN classification are required. Keep in original packaging, dry, away from direct sunlight, and avoid punctures. Handle with standard PPE and follow the SDS/local regulations.
    Storage Store SikaFiber 155 in original, unopened packaging in a dry, cool, well-ventilated area. Protect from direct sunlight, heat, sparks, open flames, and moisture. Keep bags sealed, clean, and off the ground. Avoid excessive stacking and packaging damage. Use FIFO. Shelf life is typically 24 months when stored properly. Store indoors, away from ignition sources. Do not use damaged packaging.
    Shelf Life Shelf life: 24 months from date of manufacture when stored in original unopened packaging, dry conditions, away from direct sunlight.
    Application of SikaFiber 155 - Embossed Macro Fiber for Concrete and Shotcrete

    In ground-supported floor slabs produced for logistics terminals, distribution centers, and high-bay racking installations, SikaFiber 155 is introduced as an embossed macro-synthetic crack-control fiber that is specified by dosage rather than by mesh area. The acceptance route shifts from the nominal welded wire fabric area recognized in ACI 302.1R-15 to the flexural residual strength measured under ASTM C1609/C1609M-19a. A dosage of 4.0 kg/m³ corresponds to approximately 0.44 vol% at a polyolefin density of 0.91 g/cm³; a dosage of 6.0 kg/m³ corresponds to approximately 0.66 vol%. The slab designer retains the subgrade-drag-based joint spacing calculation because the lower elastic modulus of the polyolefin fiber does not increase the pre-crack flexural stiffness of the slab; the fiber contribution begins after the cement paste cracks, where the embossed surface anchors the polymer strand across the fracture face and transfers tension through mechanical interlock and surrounding matrix shear. The specified acceptance criteria should be the residual strengths at net deflections of L/600 and L/150, which are 0.75 mm and 3.0 mm for a 450 mm span under ASTM C1609, not the number of fibers per cubic meter alone.

    Processing on production-scale equipment shows that fiber batching sequence controls dispersion more than fiber feed rate. The concrete truck mixer or central batch plant should add SikaFiber 155 after the aggregates, cement, and water have formed a uniform paste, and mixing should continue for 4–5 minutes after the final fiber dose at a drum speed of 12–18 rpm for truck mixers. Adding the dry embossed fiber as the first constituent can generate fiber balls that wrap around mixer blades and collect behind the charging chute; wash-out testing according to EN 14889-2:2006, Annex A is recommended on the first production batches, with a coefficient of variation of fiber content below 10% for stable production. Field placement of welded wire mesh has a separate documented failure mode: mesh chairs are loaded by foot traffic and concrete placement until the mesh rests on the subbase, leaving the upper third of the slab unprotected. The integral fiber distribution avoids this placement risk. Power-trowel finishing should be carried out with low blade angle and minimal additional water because over-finishing can draw surface fibers upward and create a fuzzy surface that is not a hardened aggregate wearing course. Contraction joints are retained at the spacing calculated from the slab thickness and shrinkage gradient; the fiber does not eliminate the need for joint cutting or load-transfer mechanisms at construction joints.

    For high-bay racking legs with concentrated loads above 4.5 tonnes per leg, the slab section must still be designed as a plain or conventionally reinforced concrete slab because macro-synthetic fiber does not provide a one-for-one substitute for continuous steel reinforcement in resisting flexural tension or punching shear. The fiber is not a structural load path in the design sense of ACI 318-19 or EN 1992-1-1:2004; it controls crack propagation after the concrete has reached its tensile capacity.

    What Changes When Embossed Macro Fiber Enters the Wet-Mix Shotcrete Stream?

    When the mixed concrete enters the delivery hose of a wet-mix shotcrete pump, SikaFiber 155 is subjected to shear in the pump, the 50–75 mm delivery line, and the nozzle assembly before the alkali-free accelerator is injected. The product is batched at the plant, and the mix must remain pumpable at a slump of 150–200 mm while providing enough early stiffness after accelerator addition to adhere to the rock or soil substrate without sloughing. The lower specific gravity of the embossed polymer fiber compared with steel fiber reduces fiber segregation in the pump hopper, but early addition of dry fiber to dry aggregates can still create dry fiber balls that block the hose at the nozzle coupling. The central mixer must therefore run for at least 5 minutes after the final fiber dose, and the batch should be visually checked for dispersed fibers before being transferred to the shotcrete pump. Material compliance is checked against ASTM C1436/C1436M for shotcrete materials and ACI 506R-16 for placement practice.

    Acceptance of fiber-reinforced shotcrete is based on energy absorption measured on statically compacted round or square panels, not on compressive cylinder strength alone. The governing test methods and typical acceptance bands are listed in the following matrix.

    Test standardSpecimen configurationMeasured parameterTypical acceptance band
    ASTM C1550-20Round panel 800 mm × 800 mm × 75 mmEnergy absorption to central deflection 25 mm500 J, 700 J, 1000 J classes
    EN 14488-5:2006Square panel 600 mm × 600 mm × 100 mmEnergy absorption to central deflection 25 mmClass E500/E700/E1000
    EN 14488-3:2006Beam 150 mm × 150 mm × 600 mmFlexural residual strength at 0.5 mm and 2.0 mm CMODProject-specific

    Nozzleman technique remains the controlling placement variable. The nozzle is held 0.5–1.5 m from the receiving surface, with air volume at the nozzle in the range of 5–10 m³/min at an operating pressure near 7 bar. Excessive air above 10 m³/min increases rebound and carries embossed fibers away from the fresh layer, while insufficient air below 5 m³/min produces a dense stream that does not compact the material and can leave shadowing behind reinforcing bars. Rebound of macro-synthetic fiber is generally lower than steel fiber on a mass basis, but the hardened in-place fiber content should still be verified by coring or wash-out on sprayed test panels rather than assumed from the batch sheet. The nozzle is moved in small circular passes to build layers of 50–100 mm per pass, and the next pass is placed only after the previous layer has achieved enough early strength to resist sagging. Alkali-free accelerators typically produce final set in 2–5 minutes at 20 °C, but cold substrate below 10 °C retards setting and requires revalidation of the accelerator dose under site conditions. The terminal product is a primary tunnel lining or rock-support membrane with post-crack residual load capacity, used before the final cast-in-situ lining or as permanent support in low-risk rock units.

    Demolding, Handling, and Edge Protection in Precast Concrete

    Precast boxes, utility vaults, offset risers, and drainage channels are stripped after 16–24 h of curing, when the cement paste has reached enough compressive strength for form release but not enough tensile ductility to resist lifting and transport microcracks at the edges of lifting sockets and form reveals. SikaFiber 155 at 3.0–5.0 kg/m³ provides isotropic post-crack tensile capacity after microcracks have initiated, and the governing compliance path is ASTM C1116/C1116M Type III synthetic fiber-reinforced concrete with plant quality control under Precast/Prestressed Concrete Institute MNL-116. Flexural performance is verified on beams per ASTM C1609, with the test beam taken in the same orientation as the in-service load path because external vibration at 50–60 Hz can orient fibers parallel to vertical mold faces. Edge spalling during demolding is reduced only when proper draft angles, form release agents, and lifting inserts are already present; the fiber does not replace these requirements. The terminal precast element is still designed for the same service loads as a reinforced or unreinforced concrete section under ACI 318-19 or EN 1992-1-1:2004, and the fiber is not a substitute for reinforcement mandated for structural bending, shear, or anchorage.

    Fiber Volume Fractions Above 0.3% Alter the Post-Crack Flexural Response

    For embedded rail systems in tramways, light-rail corridors, and port crane pavements, the concrete infill between or below the rails is often unreinforced in the thin cover zones above the rail foot. SikaFiber 155 is dosed at 4.0–6.0 kg/m³, producing a volume fraction above 0.3%, which shifts the post-crack response from a deflection-softening matrix toward a pseudoplastic or deflection-hardening response depending on the cement paste toughness and aggregate interlock. The transition is measured by ASTM C1609 residual strength at 3.0 mm net deflection; in a low water-cement ratio mix with rounded siliceous aggregate of 10 mm top size, the residual strength may be 30–45% of the first-crack flexural strength, but published data for this exact embossed geometry in rail-track concrete are limited and project-specific beams are required. In self-consolidating infill mixes with a slump flow of 600–700 mm per EN 12350-8, the fiber must be added at the batch plant and the slump flow must be measured before and after fiber addition because the fibers typically reduce flow by 50–100 mm. The terminal embedded rail slab must meet the rail housing geometry tolerances on the approved installation drawing; the fiber contribution is confined to crack-width control and spall reduction under dynamic wheel loads, not to the flexural capacity of the slab as a structural element.

    Repair concrete and structural overlays placed on deteriorated bridge decks, parking garage ramps, and industrial loading bays introduce a differential moisture sink at the interface between the old substrate and the new cementitious layer. SikaFiber 155 is suitable for thicker section repairs exceeding 75 mm, where it is dosed at 4.0–6.0 kg/m³ and provides post-crack tensile capacity that reduces the propagation of shrinkage cracks in the overlay. The practical lower thickness boundary is approximately 2.5–3.0 times the nominal fiber length; below this, the embossed macro fiber approaches the overlay thickness and trowel finishing can lift fiber ends through the surface. The governing material specification is EN 1504-3 for structural repair products or ASTM C928/C928M-20 for packaged dry repair concrete, and mechanical properties must be established on the actual repair mix rather than on a generic concrete.

    Surface preparation is the controlling process variable. The substrate is roughened by hydrodemolition or captive shot blasting to a concrete surface profile of at least CSP 6 per ICRI 310.2R, and a bonding slurry is applied before the repair concrete is placed by low-velocity pumping or by hand. Wet curing with a curing compound meeting ASTM C309 is required for at least 7 days because plastic shrinkage can overwhelm the crack-control contribution of the fiber if the overlay dries too quickly. The terminal product is a bonded repair layer that remains attached to the old concrete and does not act as an independent structural element; the fiber content is not a replacement for reinforcing steel where the overlay spans over a delaminated or spalled area.

    When Shotcrete Ground Support in Deep Mining Requires Energy Absorption Beyond 700 J

    In deep mining ground support, the rock mass around an advancing heading is subject to stress redistribution that can generate fractures, bulking, and ejection of rock fragments before the final lining is installed. Fiber-reinforced shotcrete containing SikaFiber 155 is applied as a surface support layer to contain loose rock pieces and to transfer ground pressure to rock bolts. The energy-absorption requirement is selected from the EFNARC panel test classes, with class E700 or E1000 typical for burst-prone ground and class E500 used in blocky but stable ground. The dosage required to reach a given class is not a linear function of fiber content; it depends on compressive strength, aggregate top size, silica fume content, and accelerator type. Published data for this specific embossed macro-synthetic fiber in hard-rock mining are limited, so the mix must be pre-qualified by round panels per ASTM C1550 or square panels per EN 14488-5 at the actual spray thickness and curing temperature.

    Application in a typical underground heading uses a robotic manipulator with the nozzle held 0.5–1.2 m from the rock face. The first layer is sprayed to a thickness of 40–60 mm and allowed to set before the next pass; subsequent layers are built up to a total thickness of 80–120 mm depending on the rock mass rating and the required support class. The low-density embossed fiber tends to follow the cement paste stream instead of bouncing off the rock face, but excessive air volume can trap fibers in rough rock apertures and remove them from the effective cross-section. Spray operators verify in-place fiber content by coring the hardened shotcrete and conducting wash-out or visual inspection of core fractures. The terminal product is a rock-support membrane with residual load-bearing capacity after cracking; it is not a replacement for rock bolts, wire mesh, or lattice girders where the ground control plan requires them, but it can reduce the time spent on manual mesh installation and improve support continuity in irregular rock profiles.

    Free Quote

    Competitive SikaFiber 155 - Embossed Macro Fiber for Concrete and Shotcrete prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    SikaFiber 155 is an embossed macro synthetic fiber for concrete and shotcrete consisting of 100% virgin polypropylene monofilaments with a nominal length of 54 mm and an equivalent diameter of 0.55 mm. The fiber has a specific gravity of 0.91 g/cm³, negligible water absorption, and a melting temperature near 160 °C; the nominal aspect ratio is calculated as 98. The product is typically supplied in collated water-soluble units that permit direct dosing by mass into a truck mixer, central batch plant, or shotcrete hopper. Under EN 14889-2:2006, the fiber is classified as a structural macro fiber when incorporated within the manufacturer’s recommended dosage range of 2.0–6.0 kg/m³. The embossed surface profile differentiates the product from smooth monofilament and fibrillated polypropylene fibers by increasing mechanical interlock with calcium silicate hydrate paste and aggregate across a propagating crack. The product is not a primary flexural reinforcement replacement for rebar in structural sections; its function is post-crack residual strength and crack-width control when dosed according to a project-specific design.

    Embossed Geometry and Stress Transfer in Cementitious Systems

    Stress transfer in the hardened matrix is governed by the fiber aspect ratio, the ribbed or embossed surface topography, and the interfacial friction that develops after initial cracking. For SikaFiber 155, the manufacturer reports a monofilament tensile strength of 600 MPa under ISO 527-1/ISO 527-2, with an elastic modulus of approximately 9 GPa. At the recommended dosage of 3.0 kg/m³, the nominal fiber count is approximately 2.57 × 10⁵ fibers per m³, based on a per-fiber mass of 11.7 mg. The corresponding fiber surface area is approximately 24 m² per m³ of concrete; at 4.0 kg/m³, the fiber count increases to approximately 3.43 × 10⁵ fibers per m³ and the surface area to approximately 32 m² per m³. This concentration is high enough to bridge microcracks that form near aggregate boundaries, but it does not transform brittle cement paste into a strain-hardening material under uniaxial tension. Flexural performance is evaluated by ASTM C1609/C1609M or ASTM C1399/C1399M depending on the project; in both methods, the residual load at specified net deflections is the acceptance criterion, not the peak flexural strength.

    In wet-mix shotcrete operations, the fiber is introduced either at the batch plant through the aggregate weigh hopper or directly into the truck mixer at the site. Manufacturer guidance for collated macro fibers requires a minimum mixing time of 5 minutes after the final water and high-range water reducer are added; the drum speed should be sufficient to prevent the wet collated units from lodging at the chute or seam. A production-scale failure mode observed with this fiber class is the formation of fiber balls when the entire dosage is added to a stationary mixer with less than 20% of the mixing water present. Cold mixing water below 10 °C slows the dissolution of the water-soluble packaging and increases the risk of undispersed bundles. The dispersed fiber does not alter the initial slump significantly at dosages up to 3.0 kg/m³; above 4.0 kg/m³, high-shear mixing and mid-range or high-range water reducers are commonly required to maintain pumpability.

    In high-shear pan mixers used in precast applications, the collated units are typically added after dry blending of aggregates and cement but before the total mixing water reaches 70%. Paddle speed in the range of 1.5–2.0 m/s can break the water-soluble film and distribute individual fibers within 3–5 minutes. In planetary mixers, fibrous agglomerations have been observed when the water-soluble film dissolves prematurely in a high-humidity storage environment; storing the product in dry, covered conditions and protecting bags from contact with wet aggregate splashes reduces this occurrence. The dosage rate should be controlled by a fiber feeder or by whole-bag addition to avoid differences between batches, since poor weighing and partial bag addition can produce fiber dosage variations exceeding ±0.5 kg/m³.

    What Distinguishes SikaFiber 155 from Hooked-End Steel Fibers in Structural Ground Support?

    Steel fibers rely on a high elastic modulus of approximately 210 GPa and mechanical end hooks to transfer load across a crack; polypropylene macro fibers rely on distributed surface interlock over the embedded length. The lower modulus of SikaFiber 155, reported as approximately 9 GPa, means that for a given crack width, the synthetic macro fiber imposes a lower restraining force until the fiber is engaged by frictional slip. In aggressive water or chloride-laden shotcrete linings, however, the absence of corrosion product formation eliminates rust staining and section loss at hairline cracks. In ground support applications, the required dosage is typically 4.0–6.0 kg/m³ and is validated by round panel testing according to ASTM C1550. Direct substitution of steel fibers with SikaFiber 155 on a weight-for-weight basis is not technically valid; replacement should be based on equivalent residual strength or energy absorption requirements established from trial panels.

    Property Value Basis / Reference
    Base polymer 100% virgin polypropylene Manufacturer technical data sheet
    Specific gravity 0.91 g/cm³ ISO 1183-1
    Nominal fiber length 54 mm Manufacturer dimensional specification
    Equivalent fiber diameter 0.55 mm Manufacturer dimensional specification
    Aspect ratio 98 Calculated from nominal dimensions
    Tensile strength 600 MPa ISO 527-1 / ISO 527-2
    Modulus of elasticity approx. 9 GPa Manufacturer material data
    Melt temperature approx. 160 °C ISO 11357-3
    Water absorption nil Polyolefin material property
    Recommended dosage 2.0–6.0 kg/m³ Manufacturer product data sheet
    Classification Structural macro fiber EN 14889-2:2006

    For slab-on-grade and suspended slab applications, SikaFiber 155 is used at 2.0–4.0 kg/m³ as a welded wire reinforcement alternative for crack control. The basis of design is often the residual flexural strength at net deflections of L/600 and L/150 under ASTM C1609/C1609M. The product’s density is lower than steel fibers, which permits lower material handling loads and reduces the total fiber mass introduced into the concrete by approximately 88% compared with the same volume of steel. However, the equivalent flexural strength at a 3.0 kg/m³ dosage depends on aggregate type, cement content, mixing intensity, and curing; published performance values for a specific concrete mixture cannot be assumed. Trial mixes are required because limestone and quartzite coarse aggregates produce different interfacial friction and may change the measured post-crack residual values.

    When Shotcrete Panels Are Tested Under ASTM C1550 for Energy Absorption

    Shotcrete specifications for temporary and permanent linings commonly require a target energy absorption at a central deflection of 25 mm in the round panel test ASTM C1550. Panel dimensions are 800 mm diameter and 75 mm thickness; the loading rate and support conditions follow the standard. For SikaFiber 155, project specifications often set a minimum dosage of 4.0 kg/m³ and require a minimum panel energy absorption class based on ground quality and excavation sequence. The sprayed concrete performance is influenced by nozzle distance, air pressure, and spraying angle, because macro fibers orient preferentially parallel to the sprayed layer and the orientation factor is reduced when the nozzle is held at excessive distance or oblique angles. Nozzleman certification and preconstruction sprayed test panels are standard controls, because fiber geometry alone does not compensate for poor compaction or excessive rebound. For dry-mix shotcrete, the fiber is added to the dry concrete blend before the screw feed or gun; uniform dispersion in the dry aggregate-cement blend is required because separation during pneumatic transport is possible if the conveyor air speed is too high.

    Parameter / Behavior SikaFiber 155 Hooked-end Steel Fiber
    Density 0.91 g/cm³ approx. 7.85 g/cm³
    Tensile strength 600 MPa 1000–1500 MPa, wire dependent
    Elastic modulus approx. 9 GPa approx. 210 GPa
    Corrosion response in cracked matrix No electrochemical corrosion Surface oxidation possible in chloride-laden environments
    Electromagnetic interference None Present
    Pumping equipment wear Low Higher due to steel-against-steel impact
    Typical structural dosage 2.0–6.0 kg/m³ 15–40 kg/m³
    Conformity standard EN 14889-2:2006 EN 14889-1:2006

    Compared with monofilament synthetic micro fibers of 19 mm or shorter, SikaFiber 155 occupies a different performance class. Micro fibers are typically dosed at 0.6–1.8 kg/m³ to control plastic shrinkage cracking during the first 24 hours; they do not impart measurable post-peak flexural capacity to hardened concrete. SikaFiber 155, with a nominal length of 54 mm and dosage above 2.0 kg/m³, bridges cracks after matrix hardening and contributes to residual strength measured under ASTM C1609/C1609M. The two fiber classes should not be interchanged in specifications without recalculation of dosage and without considering the exposure condition, because plastic shrinkage control and structural crack-width control address different cracking mechanisms.

    The polypropylene matrix of SikaFiber 155 is chemically stable in the alkaline solution of portland cement paste, which typically has a pH of 12.5–13.5. Chloride ions, sulfate ions, and carbon dioxide do not initiate electrochemical corrosion reactions because the fiber contains no metallic phase. In contrast, steel fibers at cracks exposed to deicing salts or marine aerosol may exhibit surface oxidation, which can lead to aesthetic staining and, in severe cases, reduced section. The polypropylene macro fiber is also compatible with ordinary portland cement, fly ash, silica fume, ground-granulated blast-furnace slag, and metakaolin blends, although silica fume concrete with low water-binder ratio may require higher mixing energy to disperse the fibers uniformly.

    In fire conditions, the embedded polypropylene macro fiber melts at approximately 160 °C, leaving channels that are reported in the technical literature to relieve vapor pressure in high-density concrete; however, the structural contribution of the fiber disappears after melting. This behavior is fundamentally different from steel fibers, which retain strength at elevated temperatures but have higher thermal conductivity. For concrete exposed to fire, the use of SikaFiber 155 does not eliminate the need for conventional reinforcement or passive fire protection. The ISO 11357-3 method characterises the melting peak, and the fiber’s combustibility outside the hardened matrix means storage and handling should avoid open flame and high-radiation heat sources.

    Precast segmental linings, utility vaults, and cable troughs use the macro fiber at dosages between 2.0 kg/m³ and 4.0 kg/m³ to reduce edge chipping and handling damage. The product is not a substitute for primary reinforcing bars in flexural members; its post-crack strength contribution is expressed as a residual strength index, not as yield stress. Designers should verify minimum dosage by producing trial panels or cylinders under the same batching, mixing, and curing conditions anticipated on site. Factors such as paste volume, aggregate angularity, sodium gluconate-based admixtures, and concrete temperature can alter the fiber–matrix bond, making preconstruction validation necessary rather than relying on nominal datasheet values.