Liwei Group Co., Ltd

Products

SikaFiber 240 - Structural Polypropylene Fiber for Reinforcing Cast Concrete

    • Product Name: SikaFiber 240 - Structural Polypropylene Fiber for Reinforcing Cast Concrete
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 140120
    Product Name SikaFiber 240 - Structural Polypropylene Fiber for Reinforcing Cast Concrete
    Material Polypropylene
    Fiber Type Macro synthetic
    Color Grey
    Length 38 mm
    Diameter 0.8 mm
    Aspect Ratio 48
    Tensile Strength 550 N/mm²
    Elastic Modulus 6 GPa
    Density 0.91 g/cm³
    Melting Point 160 °C
    Ignition Point >350 °C
    Alkali Resistance Excellent
    Water Absorption Nil
    Recommended Dosage 3-9 kg/m³
    Compliance EN 14889-2 Class II

    As an accredited SikaFiber 240 - Structural Polypropylene Fiber for Reinforcing Cast Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SikaFiber 240 is packaged in 12 kg cartons, each containing 20 x 600 g bags for reinforcing cast concrete.
    Container Loading (20′ FCL) 20′ FCL: non-hazardous SikaFiber 240 palletized bags, shrink-wrapped, loaded securely in clean, dry container; moisture-protected, weight evenly distributed.
    Shipping SikaFiber 240 is not classified as dangerous goods for transport. Ship in original sealed bags or cartons, palletized and shrink-wrapped, protecting from moisture, contamination, and physical damage. Store in a dry, ventilated area. Handle with normal PPE and follow local regulations and the SDS.
    Storage Store SikaFiber 240 in a cool, dry, well-ventilated area, using original unopened packaging. Keep containers closed and protect from direct sunlight, heat, moisture, and contamination. Avoid ignition sources and excessive stacking. Follow local regulations and manufacturer guidance. Rotate stock first-in, first-out and observe recommended shelf life. Do not use if packaging is damaged or product is contaminated.
    Shelf Life SikaFiber 240 shelf life: 24 months from production when stored unopened in original packaging, dry conditions, protected from direct sunlight.
    Application of SikaFiber 240 - Structural Polypropylene Fiber for Reinforcing Cast Concrete

    In high-bay logistics buildings where very-narrow-aisle racking legs impose static point loads above 80 kN per upright, cast-in-situ ground-supported floor slabs utilising SikaFiber 240 are specified as a partial replacement for conventional steel fabric in early-age crack control. The compliance envelope for this application is governed by ASTM C1116/C1116M-23 Type III synthetic fibre classification, ASTM C1609/C1609M-19 for flexural post-crack residual strength, Concrete Society TR34 for industrial ground-floor design, and ASTM E1155-20 for floor profile tolerance. Typical dosage falls between 2.5 kg/m³ and 4.0 kg/m³; the upper band is selected where racking leg loads exceed 80 kN or where saw-cut joint spacing is increased above 5.0 m. In ready-mix production, the fibre is added through a conveyor-fed collated bundle dispenser after coarse aggregate and cement have been charged but before the final 20–30% of batch water is introduced; twin-shaft compulsory mixers of 2.0–4.0 m³ discharge capacity require a post-addition mixing interval of 60–90 s/m³ to prevent surface balling and interlocking at the mixer inlet. On site, concrete is placed with a laser-guided vibratory screed, power-trowelled to an FF floor flatness of not less than 50 and an FL levelness of not less than 35 under ASTM E1155-20, and protected with a membrane-forming curing compound conforming to ASTM C309-19 at 0.20 L/m² within 15 minutes of the final trowel pass. Saw-cut contraction joints are introduced at a depth factor of 0.25–0.30 times the slab thickness within 6–24 h after trowelling. Terminal product types include high-rack distribution floors served by automated guided vehicles, narrow-aisle storage slabs with induction-wire guidance, and temperature-controlled cold-store floors where the macrofibre reduces plastic settlement cracking at cut edges. The material is not a substitute for load-transfer dowels at construction joints or for structural continuity across movement joints.

    How Do Precast Tunnel Segment Moulds Respond to Synthetic Macrofibre Reinforcement?

    Substitution of steel fibre with SikaFiber 240 in carousel-based precast segment production alters compaction response because the polypropylene macrofibre has a lower specific gravity and no magnetic interaction with external high-frequency vibrators. Standard compliance is established through EN 14889-2:2006 for polymer fibres for concrete, EN 206:2013+A2:2021 for concrete composition and conformity, and design verifications under EN 1992-1-1:2004+A1:2014 for segmental lining elements. The formulation addition rate is typically 4.0–6.0 kg/m³ in concrete class C40/50 or C50/60, with the upper dosage applied to segments thinner than 250 mm or where demoulding occurs at a minimum compressive strength of 15 MPa. Batching uses a compulsory pan mixer with the fibre dispensed after 70% of total mix water has entered to reduce clumping; the target fresh concrete consistency is maintained at slump class S3, corresponding to 100–150 mm under EN 12350-2:2019. Mould filling is performed by overhead skip or screw conveyor, and external vibrators operating at 50–80 Hz are cycled in 5–10 s intervals during casting to avoid local fibre orientation at the gasket recesses. Steam curing is ramped at a rate not exceeding 15 °C/h to a plateau of 55–70 °C, and demoulding occurs after 4–6 h; the fibre contributes to edge integrity during demoulding and reduces corner spalling when segments are handled by vacuum lifting frames. Air content is maintained below 3.0% and verified under EN 12350-7:2019 to prevent compressive strength loss. Terminal product types include bored tunnel lining rings for metro systems, water transfer tunnels, and cut-and-cover segmental linings where early-age crack control at the key segment is critical. The macrofibre does not replace conventional reinforcement at the flattened key or at jacking faces where concentrated bursting stresses exceed the post-crack tensile capacity of the fibre-reinforced concrete.

    Dry-cast pipe machines operating with zero-slump concrete and immediate demoulding use SikaFiber 240 to control microcracking during the green product transfer from packerhead to steam chamber. The relevant compliance path is EN 1916:2002 for precast concrete pipes, with fibre performance validation under ASTM C1609/C1609M-19 where the project specification permits macro synthetic fibre as a distributed crack-control mechanism instead of steel cage or steel fibre; finished pipe verification follows ASTM C497-20 for external load crushing and joint integrity. Addition rates range from 3.0 kg/m³ to 5.0 kg/m³, the lower value for thick-walled culverts above 150 mm wall thickness and the upper for thin-walled storm drains below 100 mm wall thickness. The dry-cast process demands that the fibre be pre-mixed with cement and aggregate in a counter-current mixer for 45–60 seconds before the minimal gauging water is introduced; after charging, the zero-slump mixture is fed into a packerhead machine where the rotating rollerhead applies compaction at 300–500 rpm against the outer jacket. Demoulding occurs immediately when green strength reaches approximately 0.2–0.5 MPa, after which the unit is transferred to a curing chamber at 60–80 °C and not less than 90% relative humidity for 8–12 h. Finished product types include storm water culverts, box culvert sections for rail underpass drainage, manhole riser rings, and agricultural drainage conduits. The operational boundary is that macro synthetic fibre does not increase the structural crush strength of the pipe in the same manner as steel cage; it is applied where the pipe is considered non-structural or where the design relies on concrete compressive strength and distributed fibre crack control.

    When Rubber-Tyred Gantry Crane Pavements Omit Steel Fabric Reinforcement

    Because container terminal pavement slabs are subjected to dynamic wheel loads from rubber-tyred gantry cranes and reach stackers with axle loads exceeding 900 kN, SikaFiber 240 is specified in the upper third of the slab to replace conventional steel fabric where the primary function is crack-width control under concentrated twistlock and wheel-path stresses. Design references include ACI 330.2R-17 for industrial and trucking pavements and ACI 360R-10 for slab-on-ground design; conformity testing follows ASTM C1609/C1609M-19, with post-crack residual strength measured at L/400 net deflection used to verify the specified serviceability limit state. The dosage is between 2.5 kg/m³ and 4.5 kg/m³; lower values are ordered when the slab thickness exceeds 300 mm and shrinkage is controlled by aggregate grading, while higher values are assigned to panels of 4.5 m × 4.5 m or larger where joint spacing is maximised around high-bay container stacks. The placement train consists of a slipform paver or laser-controlled vibratory screed with internal pokers spaced at 300–450 mm; the fibre is mixed at the batching plant using an automated dispenser and the truck mixer rotates at 10–12 rpm during discharge to maintain fibre distribution. Wet curing is maintained for 7 days with a sprayed curing membrane conforming to ASTM C309-19, and early saw cuts are executed in a strip cut sequence at a depth of 0.25 times the slab thickness within 8–12 h after placement, before uncontrolled crack initiation at dowel basket positions. Finished product types include container stacking yard pavements, reach stacker turning aprons, and crane wheel paths under robotic gantry systems. The fibre does not replace dowels at contraction joints and cannot compensate for inadequate subgrade preparation or joint dowel omission.

    Composite Slab Pumping and Early-Age Crack Control on Galvanized Deck Profiles

    In multi-storey frames where welded wire mesh installation is difficult at the deck lap zones and edge closures, profiled steel deck composite slabs are placed by mobile boom pump and SikaFiber 240 is introduced into the concrete to address early-age shrinkage cracking before composite action develops through headed shear studs. Published production-scale data for synthetic macrofibre in this specific deck configuration remains limited; therefore the addition rate is confirmed by preconstruction pump trials rather than extrapolated from ground-slab experience. Standards governing this downstream segment include ANSI/SDI C-2017 for composite steel floor deck-slabs and EN 1994-1-1:2004 for composite design, with fibre performance verified under ASTM C1609/C1609M-19 and fibre material conformity under ASTM C1116/C1116M-23. Typical addition is 2.0–3.5 kg/m³; the dosage is deliberately kept below the upper macrofibre range to avoid local reductions in pumpability through 125 mm flexible hose reducers and to maintain a point-of-placement slump of 160–180 mm. Production involves a central-mix plant where the fibre is added by automatic dosing after 60% of mixing water, followed by a mixing interval of 50–70 s/m³ and truck mixer discharge at 10–12 rpm; the concrete is pumped through a boom with delivery pressures generally below 120 bar and placed on galvanized deck profiles of 50–80 mm rib height. Total slab thickness is usually 130–200 mm, and the wet concrete is consolidated with a truss screed or hand vibratory screed positioned to follow the deck span direction to prevent honeycombing in the dovetail closures. Curing is achieved with moisture-retentive film or a curing compound conforming to ASTM C309-19 within 12 hours of finishing. Terminal products include multi-storey car park deck slabs, mezzanine floors in distribution centres, and office podium transfer decks; in each case the fibre contributes to early-age crack control but is not a replacement for the longitudinal tensile reinforcement required by composite slab design in negative moment regions.

    Free Quote

    Competitive SikaFiber 240 - Structural Polypropylene Fiber for Reinforcing Cast Concrete prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    SikaFiber 240 is a macro-synthetic structural fiber manufactured from 100% virgin polypropylene and supplied for secondary reinforcement of cast concrete. The product is classified as a Type III synthetic reinforcing fiber under ASTM C1116/C1116M and is CE marked under EN 14889-2:2006 for polymer fibers intended for structural use. Nominal geometry is 40 mm length with a 0.8 mm circular cross-section, yielding an aspect ratio of 50. The polymer density is 0.91 kg/L, tensile strength is approximately 500 MPa, elastic modulus is approximately 5,000 MPa, and melting point is 160 °C. Water absorption of the polymer is below 0.1 % by mass under ISO 62. The product is intended for slab-on-grade reinforcement, precast elements, and shotcrete linings where control of post-crack residual strength is required. Its mechanical function is crack bridging after the cementitious matrix has exceeded tensile strain capacity; it is not intended to increase first-crack flexural strength.

    Mechanical anchorage along the fiber surface and the 50:1 aspect ratio provide pull-out resistance in well-compacted concrete. The material is non-corrosive under chloride exposure and does not produce surface staining from fiber corrosion. Alkali resistance is derived from the polypropylene chemistry; immersion in high-pH cement pore solution does not cause measurable loss of cross-section. The fiber is added in the mixer, not as a replacement for primary reinforcing bars in elevated structural members unless explicitly designed by a qualified engineer using cracked-section analysis.

    Can a 40 mm Polypropylene Macrofiber Provide Structural Redundancy in Cast Concrete?

    At a dosage of 4.0 kg/m³, the calculated fiber population is approximately 2.2 × 10⁵ fibers per cubic metre based on the nominal geometry and density. This population creates a three-dimensional distribution in the hardened matrix after proper mixing. Residual flexural performance is dosage-dependent and must be established through project-specific testing under ASTM C1609/C1609M-19a or EN 14651. Published data for exact residual strength values across all mixing and placement conditions is limited; design values therefore should be derived from trial mixes containing the same aggregate grading, cement content, and water-cement ratio as the production concrete.

    In ground-supported slabs, SikaFiber 240 is commonly specified to reduce or eliminate conventional welded wire mesh in sections where flexural demand is controlled by soil support and joint spacing. The fiber changes the post-crack load path by transferring tensile stress across discrete cracks through fiber pull-out. Pull-out resistance depends on embedment length, concrete matrix strength, and fiber surface characteristics; polypropylene fibers of this type rely primarily on mechanical interlock rather than chemical bond to the cement phase. At 3.0 kg/m³, the nominal fiber count is approximately 1.6 × 10⁵ fibers per cubic metre, and at 9.0 kg/m³ the count increases to approximately 4.9 × 10⁵ fibers per cubic metre. These figures do not directly define residual strength but indicate the fracture surface coverage available for crack bridging.

    Design documents should distinguish between plastic shrinkage crack control and structural post-crack capacity. The former is typically addressed with micro polypropylene fibers at 0.9 kg/m³, while the latter requires macro fibers such as SikaFiber 240 at dosages above 3.0 kg/m³. In elevated slabs, precast panels, and tunnel linings, the structural contribution must be verified by beam or panel testing because the low elastic modulus of polypropylene limits immediate post-crack stiffness compared with steel fibers.

    Nominal Fiber Geometry, Mechanical Properties, and Compliance Data

    The following nominal values are drawn from manufacturer product data and should be confirmed against the current published datasheet for the specific production lot.

    Table 1. Nominal properties of SikaFiber 240
    PropertyNominal valueReference method
    Fiber length40 mmManufacturer data
    Fiber diameter0.8 mmManufacturer data
    Aspect ratio50Calculated
    Density0.91 kg/LISO 1183-1
    Tensile strength500 MPaISO 527-2
    Elastic modulus5,000 MPaISO 527-2
    Melting point160 °CISO 3146
    Water absorption<0.1 %ISO 62
    ClassificationType III / Class IIASTM C1116/C1116M / EN 14889-2:2006

    Because the fiber is produced from a semi-crystalline polyolefin, the mechanical data should not be extrapolated to service temperatures approaching the melting point. The reported tensile strength and elastic modulus are short-term polymer values, not the engineering properties of the fiber-reinforced concrete composite. For composite design, the required parameters are residual flexural strength values from EN 14651 or ASTM C1609/C1609M, which include matrix-fiber interaction effects.

    When Steel Fiber Substitution Requires a Lower Modulus Acceptability Check

    Direct substitution of steel fibers with SikaFiber 240 is not performed on a mass-to-mass basis. A hooked-end steel fiber of 50 mm length and 0.8 mm diameter typically has a tensile strength in the range 1,100–1,300 MPa and an elastic modulus near 210,000 MPa. SikaFiber 240 has approximately 500 MPa tensile strength and 5,000 MPa modulus. At equal dosage by mass, the polymer fiber count is significantly higher because the polymer density is 0.91 kg/L compared with 7.85 kg/L for steel. However, the lower modulus means that cracked-section stiffness under sustained load is lower for the polypropylene fiber composite unless the dosage and geometry compensate through higher fiber count and improved pull-out distribution.

    Table 2. Comparative physical properties: SikaFiber 240 and typical hooked-end steel fiber
    PropertySikaFiber 24050 mm hooked-end steel fiber
    Density0.91 kg/L7.85 kg/L
    Tensile strength500 MPa1,100–1,300 MPa
    Elastic modulus5,000 MPa210,000 MPa
    Corrosion susceptibilityNoneSurface corrosion possible if exposed
    Magnetic influenceNonePresent
    Mixer wearLowHigher due to steel abrasion

    Polypropylene macro-fibers are specified when corrosion resistance, lower equipment wear, and reduced injury risk from exposed steel fibers are design priorities. Steel fibers are specified where higher post-crack strength and stiffness are required for structural performance under ASTM C1609/C1609M or EN 14651. The distinction between SikaFiber 240 and conventional polypropylene microfibers is equally important. A fibrillated micro polypropylene fiber of 12 mm length and 0.018 mm diameter provides several orders of magnitude higher fiber count at 0.9 kg/m³, but its short length and low diameter produce negligible post-crack structural capacity. SikaFiber 240 should not be specified as a direct replacement for micro fibers in plastic shrinkage crack control, and micro fibers should not be specified for structural post-crack resistance.

    In chemical and marine environments, the absence of corrosion in polypropylene fibers eliminates the risk of subsurface iron staining at exposed crack faces. Polypropylene is also immune to chloride-induced deterioration, unlike uncoated steel fibers. The trade-off is the reduced cut-off stiffness in cracked sections, which can influence deflection requirements for suspended slabs and structural precast units. For precast elements subject to early lifting stresses, engineers often combine macro polypropylene fibers with conventional steel reinforcing bars rather than relying on the fibers alone for lifting and handling stresses.

    Batching sequence trials on low-slump ready-mix loads indicate that fiber addition as a single mass into a stationary drum can create clumping. In a conventional ready-mix drum, the product should be added through the aggregate charging conveyor or directly as a degradable bag into the drum after the aggregate portion has been charged. A high-shear mixing interval after fiber addition is required by manufacturer batching guidance; published data for exact drum rotation speed and time for every mixer type is limited. Visual inspection after discharge should confirm that no fiber balls remain. If slump is below 20 mm, the risk of aggregation increases, and mixing time should be extended. No pre-drying is required because polypropylene is non-absorptive.

    For wet-cast precast production, dosage is typically specified between 3.0 kg/m³ and 5.0 kg/m³. In precast counter-current mixers, fibers are normally added after the sand and coarse aggregate, before cement and water, to promote dry dispersion. In ready-mix operations, degradable bags containing pre-measured fiber mass can be discharged directly into the truck drum. The fiber should not be fed through pneumatic conveying systems without antistatic controls, because polypropylene surfaces can build static charge and form aggregates in the conveying line. For shotcrete applications, dosage may be increased to 6.0 kg/m³ through 9.0 kg/m³ to achieve the required post-crack toughness class. Differential rebound in wet-mix shotcrete changes the in-place fiber content; preconstruction panels should be sprayed, cored, and tested to verify the retained fiber dosage rather than relying solely on batch records.

    Quality Control, Placement, and Operational Boundaries

    Quality control during batching should include a visual check of fiber distribution in the mixer after discharge. Differential rebound in shotcrete may alter the in-place fiber content and should be accounted for by preconstruction testing. For hardened concrete, the relevant test methods include EN 14651 for flexural tensile strength and residual strength, and ASTM C1609/C1609M for flexural performance of fiber-reinforced concrete beams. Compressive strength testing should follow EN 12390-3 or ASTM C39/C39M. The addition of macro synthetic fibers does not materially change the compressive strength at dosages up to 9.0 kg/m³, but it can reduce slump and workability. The mix should be adjusted through water-reducing or polycarboxylate admixtures rather than increasing water content, because an increased water-cement ratio directly lowers the matrix bond strength around the fiber.

    Limitations of SikaFiber 240 include its reduced modulus compared with steel fibers and its behavior at elevated temperatures. The melting point of 160 °C means that post-crack load transfer decreases at temperatures approaching the melting range. Service temperatures above 90 °C warrant evaluation of retained modulus and long-term creep under load. The fiber should not be exposed to strong oxidizing agents or aromatic hydrocarbon solvents. Air-entrained concrete with air content above 7 % may exhibit an increased risk of fiber aggregation during mixing. In troweled floor finishes, exposed surface fibers may require an additional power-trowel pass or surface treatment to achieve the specified surface profile. The product should be stored in dry conditions away from direct ultraviolet exposure to avoid polymer oxidation and static charge buildup.

    SikaFiber 240 is not a substitute for continuous steel reinforcing bars in structural members where applicable codes require primary reinforcement. It should not be used as the sole reinforcement in elevated beams, columns, or suspended slabs unless the design explicitly accounts for the lower modulus and uses cracked-section analysis. In slabs on grade, joint spacing, slab thickness, soil support, and anticipated loads must be considered together with the fiber dosage. Published data for this specific configuration is limited for some combinations of fiber dosage and aggregate grading; therefore, project-specific testing remains the controlling basis for design. The product is compatible with conventional concrete admixtures based on naphthalene or polycarboxylate superplasticizers, but compatibility testing is required only when admixture dosage exceeds the manufacturer’s upper limit.