Liwei Group Co., Ltd

Products

SikaFiber 321 (MasterFiber 321) - Macro Synthetic Polypropylene Fiber

    • Product Name: SikaFiber 321 (MasterFiber 321) - Macro Synthetic Polypropylene Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 461654
    Material Polypropylene
    Fiber Type Macro synthetic polypropylene fiber
    Form Fibrillated
    Color Gray
    Length 38 mm (1.5 in)
    Equivalent Diameter 0.56 mm (0.022 in)
    Aspect Ratio 68
    Tensile Strength 550 MPa (80 ksi)
    Young S Modulus 7 GPa (1,000 ksi)
    Melting Point 160 °C (320 °F)
    Specific Gravity 0.91
    Water Absorption Nil
    Alkali Resistance Excellent
    Dosage 1.8 - 5.3 kg/m³ (3 - 9 lb/yd³)
    Packaging 1 lb bags, 40 bags per carton
    Compliance ASTM C1116 Type III

    As an accredited SikaFiber 321 (MasterFiber 321) - Macro Synthetic Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SikaFiber 321 is supplied in 1 kg bags, 18 bags per carton (18 kg total), for concrete reinforcement.
    Container Loading (20′ FCL) 20′ FCL: palletized 10 kg bags of SikaFiber 321 (MasterFiber 321) macro synthetic polypropylene fiber; approximately 8,000 kg net per container.
    Shipping SikaFiber 321 is a non-hazardous, inert macro synthetic polypropylene fiber. It is typically shipped in 20 kg moisture-resistant bags or bulk bags on pallets. Transport is not regulated under DOT, IMDG, or IATA. Store dry, avoid moisture, and handle with normal PPE; no special shipping requirements apply.
    Storage Store SikaFiber 321/MasterFiber 321 in original, unopened packaging in a cool, dry, well-ventilated area. Keep bags sealed and pallets off the ground. Protect from moisture, direct sunlight, heat, ignition sources, and contamination. Avoid excessive stacking. Observe first-in, first-out stock rotation; refer to the current SDS/TDS for shelf life and specific requirements.
    Shelf Life Shelf life is typically 24 months from manufacture if stored in unopened, undamaged original packaging under dry conditions, protected from sunlight.
    Application of SikaFiber 321 (MasterFiber 321) - Macro Synthetic Polypropylene Fiber

    In the production of large-area ground-supported industrial slabs where the joint layout is extended beyond 6.0 m and a laser screed controls the base level, MasterFiber 321 is introduced as secondary reinforcement for early-age crack control rather than as a direct replacement for structural steel. The batching order in a twin-shaft compulsory mixer with a rated output of 1.0 m³ to 2.5 m³ places the fibre after coarse aggregate, cement, and fine aggregate have been dry-mixed for 60 s to 90 s but before the final free water is added. This sequence reduces the formation of fibre balls at the mixer gate, because a low-density hydrophobic fibre with specific gravity near 0.91 g/cm³ will otherwise float on the water film and agglomerate in the charging hopper. At 3.0 kg/m³ to 5.0 kg/m³, the volume fraction is approximately 0.33% to 0.55%, a range that provides crack-width control without transforming the fresh concrete into an excessively fibrous mass at the tailgate of a truck mixer. Slump is maintained at 120 mm to 160 mm measured according to EN 12350-2, and the batch record logs fibre addition by mass rather than by bag count, because static clumping and torn packaging can change the actual fibre count per cubic metre even when the nominal weight is recorded as correct. Early-age plastic shrinkage behaviour is quantified under ASTM C1579-21, and post-crack residual strength is measured under ASTM C1399/C1399M-10 at a net deflection of L/150. Published data for the exact residual strength ratio of this product at this dosage envelope is limited and must be confirmed on a trial slab with the same aggregate angularity and paste volume as the production mix.

    The main production conflict on ground-supported slabs is finishability during the power-trowel window, not fibre dispersion. A ride-on power trowel with its final-pass blade pitch set above 15° drags surface fibres out of the closed paste, producing a fuzzy surface that cannot be corrected by additional finishing passes. The trowel operator must therefore lower the blade angle on the final two passes and maintain a total finishing time within the bleed-water evaporation window. At relative humidity above 60%, the evaporation rate is slower, but bleed water can accumulate under a prematurely closed surface and trap fibres in the top 2 mm of the slab. Joint sawing is scheduled in an early-cut window of 4 h to 8 h after final trowelling; if sawing is delayed beyond 12 h, random plastic shrinkage cracks can cross the intended panel pattern and invalidate the joint-spacing assumptions used to select the fibre dosage. Edge compaction around embedded rails and pit frames is performed with a vibrating screed before initial set, and the vibrator should not be held in one position for more than 30 s because prolonged local vibration drives the low-density fibres away from the form face.

    At What Dosage Does Macro-Synthetic Fibre Alter Pumping Pressure in Wet-Mix Shotcrete?

    In wet-process shotcrete for temporary tunnel linings and rock-slope stabilisation, MasterFiber 321 is batched into the concrete at the plant and the mixture is delivered through a piston pump to the nozzle. At 4.0 kg/m³ to 8.0 kg/m³, the fibre volume fraction reaches 0.44% to 0.88%, a level that influences the pumping resistance of the fresh mix but does not replace primary bar reinforcement in a structurally active tunnel lining. The effect on pumping pressure is governed more strongly by minimum paste volume, maximum aggregate size, and the number of bends in the delivery line than by fibre mass alone; because published data for the exact pressure differential at this dosage is limited, the batching plant should be instrumented with a pressure transducer rated to 80 bar at the pump outlet to separate fibre-related pressure rise from aggregate packing effects. Conveying line diameters of 50 mm to 75 mm are typical for wet-mix shotcrete, and bends with a centreline radius below 500 mm should be avoided because macro-synthetic fibres can collect at the inner radius and form a plug when the line is stopped for more than 15 min. The fibres remain dispersed because the specific gravity is close to that of the cement paste suspension, but static bleeding in a stationary line will still produce an upper-layer fibre concentration that must be flushed before restarting the pump.

    Accelerator selection controls whether the placed fibre network develops its design post-crack performance. Alkali-free aluminium sulfate accelerators dosed at 3% to 10% by mass of cement do not degrade the polypropylene matrix and allow the fibre bond to develop along with the hydrating paste. Sodium silicate accelerators above 12% by cement mass can reduce later-age strength by more than 20%, and the damaged cementitious matrix makes any fibre contribution difficult to isolate from early-age shrinkage cracking. The sprayed concrete is applied in layers of 50 mm to 150 mm per pass, with the nozzle held 0.8 m to 1.2 m from the substrate and at an angle no greater than 30° from perpendicular to limit fibre loss in rebound. Rebound in wet-mix shotcrete preferentially removes low-density fibres and coarse aggregate, so a placement record that shows low rebound loss but does not verify placed fibre content can overstate the actual fibre dosage in the hardened lining. Cores extracted under EN 14488-1 are washed out to count fibres per unit volume, and energy absorption is measured under ASTM C1550-12a or EN 14488-5 depending on the project specification.

    Compliance verification matrix for MasterFiber 321 in wet-process shotcrete
    Verification areaStandard or codeParameter
    Polymer fibre classificationEN 14889-2:2006Fibre geometry, tensile strength, alkali resistance, mix compatibility
    Fresh sprayed concrete samplingEN 14488-1Core extraction and preparation of hardened sprayed concrete panels
    Post-crack energy absorptionASTM C1550-12aEnergy absorbed at central deflection of 40 mm
    European post-crack performanceEN 14488-5Energy absorption class of fibre-reinforced slab specimen
    Fibre-reinforced concrete typeASTM C1116/C1116M-10aType III synthetic fibre concrete

    Precast façade panels cast in open moulds on a daily production cycle use MasterFiber 321 at 2.0 kg/m³ to 4.0 kg/m³ to reduce demoulding cracks and edge damage during lifting. The concrete is proportioned with a flowable consistency of 300 mm to 500 mm slump, allowing placement in moulds with limited compaction; fibre addition at this dosage does not alter the maturity curve of the cement paste because polypropylene is chemically inert and does not consume mixing water. The main batch-to-batch defect on architectural precast lines is surface pitting at sharp corners, where low-density fibres accumulate under prolonged poker vibration. To limit this defect, external form vibrators are operated for no more than 30 s to 60 s per lift, and internal poker vibrators with a head diameter below 40 mm are inserted for less than 8 s per position. Demoulding at 16 h requires the minimum stripping strength specified by the formwork supplier, not a change in fibre dosage; if the panel is removed before the concrete reaches that threshold, corner cracking occurs regardless of the fibre content. Panels exposed to driving rain are checked for water absorption under EN 12390-8, but the fibre itself does not provide a waterproofing barrier and should not be specified as a replacement for crack-bridging membranes in below-grade conditions.

    Concrete mix adjustments for architectural precast panels must account for the extra surface area contributed by the fibre. Although polypropylene is hydrophobic and has negligible water absorption, the addition of macro fibres at 2.0 kg/m³ to 4.0 kg/m³ can reduce the slump by 10 mm to 30 mm depending on aggregate grading and cement paste volume; this is normally corrected with a polycarboxylate ether superplasticizer rather than by adding water. The water-cement ratio is kept at or below 0.50 for external cladding, and curing compound is applied within 30 min of final finish to prevent plastic shrinkage at the panel edges. Batches are checked with a wash-out test on the fresh concrete to confirm that the fibre count per cubic metre is within ±10% of the specified value; large deviations indicate fibre dosing equipment drift or agglomeration in the mixer. Published data for the exact fibre count tolerance is limited and should be established as part of the plant's factory production control under EN 14889-2:2006.

    When Precast Manholes and Cable Trenches Move from Steel Mesh to Polypropylene Secondary Reinforcement

    In precast manhole rings, cable trenches, and small utility vaults, form geometry and demoulding forces make a continuous macro-synthetic fibre phase easier to place than hand-tied steel mesh. MasterFiber 321 is dosed at 4.0 kg/m³ to 6.0 kg/m³ in a zero-slump or low-slump concrete that is placed on a turntable or stationary casting machine. The fibre is introduced through an automatic dispenser synchronised with the mixer discharge, because manual bag addition into a low-workability mix with a slump below 50 mm creates fibre clumps that survive into the hardened product. The concrete is compacted by external vibration and, in some plants, by a roller head that shapes the inner surface of the manhole base. The roller head pressure is kept below 0.3 N/mm² during compaction to avoid forcing fibres into the outer steel form face; published data for the exact pressure limit is limited, so plant-specific adjustment is required. Hardened concrete is tested for compressive strength under EN 12390-3 and for crack control under ASTM C1116/C1116M-10a Type III classification. Hydrostatic tightness of manhole sections is verified under EN 1917 or the project-specific national annex, and the fibre does not contribute to watertightness; the concrete mix and the gasket connection remain the controlling components.

    Demoulding of vertical manhole rings produces a stress field concentrated at the bolt-down inserts and the lift holes. A macro-synthetic fibre that reinforces against plastic settlement cracking will not address structural lifting stresses unless the panel is designed as a fibre-reinforced concrete section with post-crack residual strength under ASTM C1399/C1399M-10. For products with wall thickness below 100 mm, fibre dosage above 6.0 kg/m³ may reduce the effective compaction of the concrete and produce internal honeycombing at the inner and outer form faces. Published data for this specific geometry is limited; therefore, the plant should run a trial casting with the proposed dosage and cut the unit to check fibre distribution before production release.

    Marine Armour Units and Wave-Deflecting Structures

    Coastal armour units and wave-dissipating concrete elements placed in the splash and tidal zones under exposure classes XS2 and XS3 of EN 206 encounter chloride ingress and cyclic wetting, conditions that make steel fibres vulnerable to corrosion staining and local spalling even when the bulk concrete cover is intact. MasterFiber 321 is inert in seawater, absorbs less than 0.1% moisture by mass, and therefore maintains a stable fibre volume under wet-dry cycling. The fibre is proportioned at 4.0 kg/m³ to 7.0 kg/m³ in a concrete with a water-cement ratio below 0.45 and a minimum cement content of 360 kg/m³ to provide the dense paste required for chloride resistance. Placement is typically by crane skip rather than by long-line pumping, so the pumping-pressure conflict observed in shotcrete is replaced by surface-finish and form-release problems. External vibrators clamped to the form faces must not be operated for more than 90 s per lift because prolonged vibration drives the low-density polypropylene fibres toward the form surface and produces a dense fibre layer that traps air. The hardened concrete is tested for freeze-thaw resistance under ASTM C666/C666M-15; an air-entraining agent is still required at 5% to 8% air content because the macro-synthetic fibre does not create the same protective air-void network as chemical admixtures.

    The design of marine structures with macro-synthetic fibres must separate uncracked and cracked section behaviour. The elastic modulus of polypropylene is in the range of 3.5 GPa to 7.0 GPa, roughly two orders of magnitude below steel at approximately 200 GPa, so the fibre network does not raise the first-crack flexural strength of the concrete. Once the matrix has cracked, energy absorption under ASTM C1550-12a round-panel loading becomes the relevant performance indicator, but design calculations must not transfer the post-crack energy value into an increase in ultimate bending moment unless a project-specific European Technical Assessment validates that substituted reinforcement. The total chloride content of the concrete batch is documented under EN 206 and the fibre itself does not contribute chloride or sulfate ions; however, mixing water and aggregates from coastal sites can introduce chloride above threshold if not managed carefully.

    In bonded and unbonded cementitious floor screeds where the installed thickness is below 40 mm, MasterFiber 321 is limited to plastic crack control during drying and cannot correct deflections or edge debonding caused by substrate movement. The fibre is dosed at 0.9 kg/m³ to 1.8 kg/m³ and dispersed in a forced-action mixer before the screed is pumped; no additional performance testing beyond EN 13813 screed material classification is required unless project specifications call for residual strength. The main production constraint is the interaction between fibre strands and a rotor-stator pump, where fibre accumulation at the stator inlet can occur if the strand length exceeds the auger pitch; the use of a monopump with a large continuous cross-section reduces this risk.

    Free Quote

    Competitive SikaFiber 321 (MasterFiber 321) - Macro Synthetic Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    SikaFiber 321, formerly marketed under the MasterFiber 321 designation, is a macro synthetic polypropylene fiber engineered for control of drying-shrinkage, temperature-shrinkage, and load-induced cracking in cementitious composites. The material is supplied as an embossed monofilament with a nominal length of 54 mm and a specific gravity of 0.91. Under ASTM C1116/C1116 the product is classified as a Type III macro-synthetic fiber; under the European harmonized framework it is evaluated against EN 14889-2 for polymer fibers in concrete. The primary function is not to replace structural reinforcement but to provide post-crack residual strength and crack-width control in slabs-on-grade, sewer and tunnel linings, precast elements, and sprayed concrete.

    Manufacturer-published typical values include tensile strength of 600–640 MPa and modulus of elasticity near 9.5 GPa. Water absorption is reported below 0.1%, so the fiber does not require pre-drying before batching under standard storage conditions. The low modulus relative to steel fiber is the main material limitation: at equal volume fraction, post-crack flexural strength is lower than that achieved with hooked-end steel fiber, and structural design should not use the product as primary load-resisting reinforcement unless approved through project-specific performance testing.

    Filament Surface Embossment Governs Pull-Out Resistance

    The contribution of a macro synthetic fiber to post-crack behavior depends on both the tensile strength of the filament and the mechanical anchorage generated at the fiber-matrix interface. The surface configuration of SikaFiber 321 is designed to engage the cement paste through interfacial friction and local bearing. Pull-out resistance is therefore evaluated indirectly through standardized flexural tests on fiber-reinforced concrete rather than through isolated filament extraction values. Cited test methods include ASTM C1609/C1609M-19a and ASTM C1399/C1399M. The measured parameters—peak load, residual strength at specified net deflections, and equivalent flexural strength ratio—provide a more reliable basis for dosage selection than fiber count per kilogram alone.

    In pumped concrete, dispersion is influenced by aggregate grading and paste volume. A minimum paste volume of 15% by concrete volume is typically specified at dosage rates above 6.0 kg/m³. The fiber should be added after the coarse aggregate and before or during final water addition. High-shear truck mixers at 12–18 rpm drum speed generally require 4–6 minutes of mixing after fiber addition to eliminate dry fiber clusters. Production-scale experience indicates that adding partially torn bags or loose fiber to a discharged portion of a load can create tailgate clumping, which is reversed only by returning the complete batch to the mixer for additional high-speed revolutions.

    What Distinguishes This Fiber from Welded Wire Mesh, Steel Fibers, and Micro-synthetic Monofilaments?

    Welded wire mesh performs as a grid-like tensile layer only if it is positioned within the upper or lower third of the slab cross-section with adequate cover. On construction sites, wire mesh placement is often pushed to the bottom by foot traffic and pump hose weight, reducing its effectiveness. SikaFiber 321 is distributed throughout the entire matrix during mixing and does not require chairs, lapping, or placement labour. The fiber is not, however, a direct substitute for reinforcing bars in beams, columns, or structural slabs requiring flexural continuity under ACI 318 or EN 1992-1-1 design assumptions.

    Steel fiber reinforcement offers higher modulus and higher residual strength at a given dosage, but it increases mixer abrasion, pump wear, and surface rust potential in exposed or thin-cover elements. Macro synthetic fiber is lower in density and does not corrode in chloride-rich or carbonated environments; however, its modulus is approximately 9.5 GPa compared with 200 GPa for steel, so a higher volume of synthetic fiber may be required to achieve equivalent crack-width control at the same deflection. Micro-synthetic monofilaments with lengths below 20 mm and diameters below 0.3 mm mainly reduce plastic-shrinkage cracking in the first 6–12 hours; they do not provide meaningful post-crack load capacity after the matrix hardens.

    Property SikaFiber 321 Hooked-end steel fiber Micro synthetic fiber Welded wire mesh
    Length 54 mm 30–60 mm 6–19 mm 100 × 100 mm or 150 × 150 mm
    Specific gravity 0.91 7.85 0.90–0.91 7.85
    Tensile strength 600–640 MPa 1000–1400 MPa 300–500 MPa 450–550 MPa
    Elastic modulus 9.5 GPa 200 GPa 3–5 GPa 200 GPa
    Typical dosage 1.8–9.0 kg/m³ 15–40 kg/m³ 0.6–1.2 kg/m³ 1.5–3.0 kg/m²
    Corrosion risk none possible at surfaces none possible

    Comparative values are typical ranges for broad product classes. Project-specific verification under ASTM C1609/C1609M-19a is required because mix constituents, aggregate size, and placement method alter residual strength more than nominal fiber properties alone.

    Dosage selection for slabs-on-grade cannot be reduced to a fixed bag rate. The controlling inputs are the design post-crack residual strength, the slab thickness, the sub-base friction, the anticipated load spectrum, and the joint spacing. Published manufacturer guidance for temperature-shrinkage control commonly begins near 3.0 kg/m³; load-induced crack control in interior slabs with hard-tire traffic frequently falls between 4.0 kg/m³ and 7.0 kg/m³. At rates above 7.0 kg/m³, additional fiber may increase residual strength further, but workability loss and non-uniform dispersion become the dominant constraints. Engineering specifications often state the target average residual strength at 1/600 net deflection under ASTM C1609/C1609M-19a, not a minimum fiber addition alone. Published data for this specific configuration is limited; a trial batch with the exact mix design and batching sequence is necessary to correlate dosage to the specified residual strength.

    When High Dosage Rates Shift the Failure Mode from Fiber Pull-Out to Fiber Clumping

    At addition rates beyond 9.0 kg/m³, the relationship between fiber dosage and post-crack performance often becomes nonlinear. Fibers that remain as entangled clusters do not transfer tensile stress across a crack; only individual filaments oriented across the fracture plane contribute. Consequently, a measured increase in bagged fiber mass does not produce an equivalent increase in residual strength if dispersion is incomplete. In low-slump concrete with a water-cement ratio below 0.40, dry fiber can form balls in the mixer, especially when added too rapidly to coaxial truck mixers without free water on the aggregate surface. The operational limit is therefore governed by mixing energy and paste volume. A high-range water reducer, an increase in fine aggregate ratio, and staged fiber addition at the plant are typical mitigations when specification dosages exceed 6.0 kg/m³. The fiber itself remains heat-stable up to about 160 °C, but concrete batch temperatures above 35 °C may accelerate slump loss in combination with the fiber’s surface area.

    In wet-mix sprayed concrete for tunnel linings and slope protection, dosage rates are adjusted to compensate for rebound. Because the fiber density is close to that of water, synthetic macro fiber rebounds less than steel fiber under comparable spraying conditions; however, the total in-place fiber content must be verified by wash-out analysis under EN 14488-7 or an equivalent specified test method. Precast covers, cable trenches, and paving units use addition rates of 4.0–6.0 kg/m³ primarily to reduce handling and transport cracking. The low fiber density also reduces abrasive wear on screw conveyors and mixing blades; this is measurable as extended service intervals on high-speed pan mixers when compared with steel fiber batches at equivalent volume fraction.

    Compliance Matrix and Specification References

    Specifiers typically call for fiber compliance through a combination of material classification and performance-based flexural testing. The product’s conformity documentation commonly includes the following test method designations and acceptance routes:

    Reference Scope Relevance
    ASTM C1116/C1116 Type III Standard specification for fiber-reinforced concrete and shotcrete Classification as macro-synthetic polypropylene fiber
    EN 14889-2 Fibres for concrete—Part 2: Polymer fibres CE marking and harmonized classification under the Construction Products Regulation
    ASTM C1609/C1609M-19a Flexural performance of fiber-reinforced concrete using a beam with third-point loading Residual strength, peak load, and load-deflection parameters
    ASTM C1399/C1399M Average residual strength of fiber-reinforced concrete Alternative residual strength method where applicable
    ISO 9001 Quality management systems Manufacturing batch consistency and traceability

    Chemical inventory requirements are typically addressed through the manufacturer’s safety data sheet, which identifies the polymer formulation and any reportable constituents under REACH. No chloride or reactive metal content is introduced by the fiber.

    Because polypropylene is inert in the alkaline concrete environment, compatibility with common admixtures is broad. The fiber should not be stored in direct contact with aromatic hydrocarbon solvents, strong oxidizing agents, or open flame. Placement in concrete exposed to sustained service temperatures above 80 °C may exceed the heat-deflection resistance of the polypropylene filament; high-temperature structural applications should therefore be reviewed against the manufacturer’s maximum service temperature guidance. In chloride-exposed elements, the fiber does not initiate or propagate corrosion, but the structural design must still provide correct cover to any steel reinforcement because the fiber cannot replace the structural role of reinforcing bars under EN 1992-1-1 or ACI 318.