| HS Code | 296097 |
| Product Name | SikaFiber 540 Twist |
| Material | Polypropylene |
| Fiber Type | Twisted macro synthetic fiber |
| Length | 54 mm |
| Diameter | 0.65 mm |
| Aspect Ratio | 83 |
| Density | 0.91 g/cm³ |
| Tensile Strength | 550 MPa |
| Elastic Modulus | 8 GPa |
| Melting Point | 160 °C |
| Ignition Point | >350 °C |
| Alkali Resistance | High |
| Water Absorption | Negligible |
| Recommended Dosage | 3-9 kg/m³ |
| Packaging | 1.5 kg bags, 20 kg bags |
| Shelf Life | 24 months |
| Compliance | EN 14889-2 Class II |
| Corrosion Resistance | Non-corrosive |
| Thermal Conductivity | Low |
| Electrical Conductivity | Low |
| Chemical Resistance | Good against alkalis, acids, and salts |
| Color | Natural |
As an accredited SikaFiber 540 Twist - Synthetic Polypropylene Macrofiber for Use in Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 1 kg bags, 20 bags per carton (20 kg), and 30 cartons per pallet (600 kg). |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized SikaFiber 540 Twist synthetic polypropylene macrofiber bags, securely strapped and stretch-wrapped for concrete reinforcement transport. |
| Shipping | SikaFiber 540 Twist is shipped as a non-hazardous synthetic polypropylene macrofiber in moisture-resistant bags or pails, palletized and shrink-wrapped. Store dry, away from ignition sources, and handle to avoid package damage. No special dangerous goods classification typically required; comply with local regulations. Use original packaging; protect from UV, moisture, and physical damage during transport. |
| Storage | Store SikaFiber 540 Twist in a cool, dry, well-ventilated, covered area in original unopened packaging. Protect from moisture, direct sunlight, heat, flames, and ignition sources. Keep pallets off the ground, avoid excessive stacking, and separate from incompatible chemicals. Recommended storage temperature is approximately 5–30°C. Use oldest stock first; shelf life is typically 24 months when stored properly. |
| Shelf Life | Shelf life is 24 months from production date when stored unopened in original packaging, dry, protected from sunlight and moisture. |
For precast utility tunnel and cut-and-cover secondary lining segments cast from C40/50 self-compacting concrete or low-slump wet-cast concrete, fibre selection is dominated not by ultimate bending moment but by demoulding stripping forces, impact during storage and transport, and long-term crack-width control in aggressive groundwater exposure. A dosage of 5.0 kg/m³ SikaFiber 540 Twist, equivalent to approximately 0.55% by volume at a polypropylene density of 0.91 g/cm³, is introduced into the pan mixer after the fine and coarse aggregates and before the addition of water and superplasticizer. Mixing is extended by 90 seconds per batch in a compulsory twin-shaft mixer to disperse the twisted fibre bundle network; batching operators monitor fibre clumping by performing a wash-out test on the first batch of each shift. Compliance is anchored to EN 14889-2:2006, EN 13369:2018 and EN 14651:2005+A1:2007, with residual flexural tensile strength measured at crack mouth opening displacement of 0.5 mm and 3.5 mm. Terminal products in this application segment include box culvert segments, cut-and-cover secondary lining panels and retaining wall facing units that do not rely on the fibre as primary flexural reinforcement. A documented processing boundary exists: where segment thickness drops below 75 mm, surface fibre visibility becomes statistically more frequent after acid etching, and a trial panel is mandatory before full production.
Steam curing at 60°C for 12 hours does not alter the polypropylene macrofibre geometry but can shift low-viscosity self-compacting concrete rheology toward the upper viscosity class. The presence of 5.0 kg/m³ twisted macrofibre typically increases the slump-flow viscosity class from VF2 to VF1 under EN 12350-8 without changing the target slump-flow diameter by more than 50 mm. Batching records treat the fibre as a solid addition, not as a water reducer; water dosage should not be adjusted unless moisture probes on the washed sand show a deviation above 0.4%. Published data for this specific configuration is limited where twin-shaft mixer fill levels exceed 80% of nominal capacity, and in such cases a reduced batch volume is applied to prevent low-energy mixing zones from producing fibre nests near the mixer discharge gate.
| Standard or guide | Scope | Measured or controlled parameter | Application scenario |
|---|---|---|---|
| EN 14889-2:2006 | Polymer fibres for concrete | Class II fibre conformity, geometry and tensile properties | All SikaFiber 540 Twist applications |
| EN 14651:2005+A1:2007 | Fibre-reinforced concrete flexural test method | Limit of proportionality and residual flexural tensile strength at CMOD 0.5 mm and 3.5 mm | Precast tunnel segments and utility elements |
| ASTM C1609/C1609M | Flexural performance of fibre-reinforced concrete | Peak strength and residual loads at specified net deflections | Industrial slab on grade |
| EFNARC 1999/2002 | Sprayed concrete specification | Energy absorption class, panel toughness and rebound control | Dry-mix shotcrete lining |
| EN 14488-1 | Testing sprayed concrete | Fresh sprayed concrete sampling and hardened test panel preparation | Dry-mix shotcrete lining |
| ASTM C1550 | Round panel flexural toughness | Energy absorption in flexure of fibre-reinforced shotcrete | Heavy-duty pavement and shotcrete |
| EN 13369:2018 | Common rules for precast concrete products | Production control, demoulding strength and dimensional tolerances | Wet-cast utility vaults and precast elements |
| EN 1992-3 | Liquid-retaining and containment structures | Design crack width and watertightness verification | Water and wastewater containment structures |
| TR34 | Concrete industrial ground floors | Slab design, joint layout and fibre dosage validation | Industrial floor slabs on grade |
Where a distribution warehouse with a racking load of 8 tonnes per upright and a floor area of 12,000 m² is poured in strip widths of 30 m, the substitution of A142 steel mesh by 4.0 kg/m³ SikaFiber 540 Twist moves the construction risk from mesh positioning to fibre distribution. The fibre is batched in a 3.0 m³ truck mixer at a batching plant; the addition sequence is half the coarse aggregate, half the sand, the full fibre dose, remaining aggregate, water and admixture, followed by high-speed mixing for 5 minutes. On-site quality control uses a 0.075 mm sieve wash-out from a 20-litre sample; fibre recovery below 95% of the batch target triggers a 30-second remix at high speed. The floor design follows Concrete Society TR34 and ACI 302.1R; performance is verified using ASTM C1609/C1609M beams at 3 days and 28 days. At 4.0 kg/m³, residual flexural strength values reported in typical site test records fall within the range required for racking aisle movement joints, but not high enough to delete armoured joints at day joints subject to forklift traffic. Terminal products are high-bay racking slabs, automated guided vehicle floors and cold-store floors where the polypropylene fibre eliminates the corrosion risk of steel mesh at sawn joints. Process boundary: at ambient concrete temperatures above 30°C, the time between batching and discharge exceeding 45 minutes increases the risk of hydrophobic fibre interlocking in the hopper; batching should be scheduled accordingly.
Dry-mix shotcrete application in underground mine headings and rock slope stabilisation requires 54 mm SikaFiber 540 Twist fibres to be metered into the hopper of a rotor-type shotcrete machine at 5.0 kg/m³ to 6.0 kg/m³. The fibre feed is calibrated using a conveyor weigh-batch system because volumetric batching at the nozzle introduces fibre count variation of up to 18% in field audits when bag dumping is uncontrolled. Air pressure at the nozzle is maintained between 3.0 bar and 4.0 bar, with water pressure at least 1.0 bar above the air pressure to prevent premature hydration of the dry mix. Nozzle distance from the substrate is held at 1.0 m to 1.8 m; at distances above 2.0 m, the rebound rate of a macrofibre-containing mix increases disproportionately due to fibre particle momentum loss. Compliance for sprayed concrete is established through EFNARC 1999/2002 and EN 14488-1; the energy absorption class is determined from panel tests in EN 14488-5. Terminal products include temporary rock support layers in sub-level open stopes, access drifts, portal slope linings and retaining wall shotcrete facings. Published project data for specific fibre rebound percentages with this exact fibre are limited; however, standard dry-mix shotcrete practice documents a rebound range of 10% to 25% for aggregate and cement with synthetic macrofibres, and the ratio should be established through a pre-construction nozzle test under EN 14488-2.
Where a permanent shotcrete lining is designed for high-energy rockburst conditions, SikaFiber 540 Twist is not a direct substitute for steel fibre reinforcement. The operational boundary is governed by the lower tensile modulus of polypropylene compared with steel; the fibre contributes crack distribution, impact toughness and corrosion-free durability but does not provide equivalent post-crack load capacity in high ground-stress intersections. Batching records from underground headings show that fibre addition into a pre-dampened aggregate stream reduces electrostatic fibre clumping in dry-mix hoppers operating below 70% relative humidity; above that threshold, the fibre should be stored in a controlled dry area and added at the discharge chute immediately before the rotor unit.
Container terminals, airside taxiways and waste transfer pavements are poured with slipform or fixed-form equipment, and the use of synthetic macrofibres in these slabs targets reduction of early-age plastic shrinkage cracking and improvement of joint edge stability rather than complete elimination of dowel bars. A dosage of 3.5 kg/m³ to 5.0 kg/m³ SikaFiber 540 Twist is combined with a C35/45 air-entrained concrete for exterior exposure; the air content is maintained at 4.5% to 6.0% in accordance with EN 206 for XF4 freeze-thaw exposure. The concrete is placed by a track-mounted slipform paver with at least four vibrators per 1.0 m of paving width; fibre addition is made at the batch plant because in-paver addition on large airport aprons has produced inconsistent fibre distribution in both transverse and longitudinal directions. Compressive and flexural performance is verified under EN 12390-3 and EN 12390-5, while fibre-reinforced toughness parameters are measured using ASTM C1550 round panel specimens. Terminal products include ISO container stacking yards, airport service roads, intermodal freight depots and bus rapid transit platforms. A critical operational boundary is that movement joint spacing and dowel basket design are not shortened solely because the fibre is present; joints are still placed at 5 m to 6 m centres for heavy-duty hardstands, and the fibre contributes to edge spall resistance but not axial load transfer across the joint.
Wet-cast electric utility vaults, pull pits, transformer bases and drainage catch basins benefit from SikaFiber 540 Twist as a replacement for light welded wire mesh that would otherwise require greater concrete cover in soil and groundwater. The mix design for these elements is a C40/50 zero-slump or 20 mm slump wet-cast concrete with a fibre addition of 3.0 kg/m³ to 4.0 kg/m³, corresponding to approximately 0.33% to 0.44% by volume. The production line uses steel moulds mounted on an external vibrator rig; vibration time is increased from 30 seconds to 45 seconds per cycled mould compared with plain concrete because the twisted fibres temporarily stiffen the no-slump mix. Stripping is performed at 16 hours when the concrete reaches 15 MPa to 20 MPa cube strength; the fibre does not reduce the minimum stripping strength but reduces the incidence of corner breakout during demoulding and forklift handling. The relevant compliance standards are EN 13369:2018 for precast elements, EN 14889-2:2006 for fibre conformity and ASTM C1116/C1116M Type III where project specifications are written under U.S. practice. Terminal products are precast manhole rings, cable pits, pump bases and drainage channel segments. A processing incompatibility exists where acid-washed exposed aggregate finishes are specified for architectural precast; the macrofibre can produce visible surface filaments at dosage above 3.0 kg/m³ under acid etching, so aesthetic panels require a pre-production surface trial.
Liquid-retaining reinforced concrete structures such as sumps, settlement tanks, secondary containment bunds and submerged inlet channels are specified to limit crack widths for watertightness, and SikaFiber 540 Twist is added to the concrete to assist with early-age crack distribution in a C35/45 mix with a water-cement ratio no greater than 0.45. A dosage of 3.0 kg/m³ to 4.0 kg/m³ is combined with conventional steel bar reinforcement; the synthetic fibre does not replace the primary crack-control steel required by EN 1992-3 or ACI 350 but adds distributed microcrack control during the first 72 hours after casting. The concrete is placed in 400 mm-thick wall and slab sections using formwork vibrators with a minimum 40 mm head diameter; immersion vibrators are inserted at 300 mm centres to avoid fibre nests near waterstop intersections. Compliance testing follows EN 12390-8 for water penetration depth, EN 12390-3 for cube strength and EN 14889-2:2006 for fibre conformity; crack width is verified by visual inspection and a limiting design crack width of 0.2 mm is used for the retaining wall faces. Terminal product types are wastewater treatment plant tanks, stormwater attenuation structures, settlement lagoons and chemical secondary containment slabs. A notable operational boundary is that the fibre does not compensate for poor curing of watertight concrete; membrane curing must be applied within 2 hours of finishing and retained for a minimum of 7 days to achieve the specified water penetration limit.
Competitive SikaFiber 540 Twist - Synthetic Polypropylene Macrofiber for Use in Concrete prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber 540 Twist is designated as a Class II macro-synthetic polypropylene fibre for concrete under EN 14889-2:2006 and is supplied as a twisted macrofiber bundle with a nominal length of 54 mm. Manufacturer datasheet values include a specific gravity of 0.91 g/cm³, tensile strength of 450 MPa, and tensile modulus of approximately 5,000 MPa. These properties place the material in the low-modulus, high-elongation polymer fibre class relative to steel wire fibres. In concrete, SikaFiber 540 Twist is typically added at a dosage of 2.0–6.0 kg/m³. At the lower end, the addition is intended primarily for plastic shrinkage and early-age crack-width limitation; at 4.0–6.0 kg/m³, the product is used for post-crack crack bridging in floor slabs and similar ground-supported elements. The fibre is added to the aggregate stream in a ready-mix plant before water, and wet mixing is extended by 4–5 minutes after all materials are charged. The twisted geometry provides mechanical anchorage in the hardened cement matrix rather than relying solely on chemical bond. Polypropylene has a melt point near 165 °C and negligible water absorption, which eliminates corrosion-related surface staining. Published data for sustained service above 80 °C in aggressive oxidative environments is limited, and such exposure requires additional validation.
Steel hooked-end macrofibres typically exhibit an elastic modulus above 200,000 MPa and a specific gravity near 7.85 g/cm³. SikaFiber 540 Twist, at 0.91 g/cm³ and 5,000 MPa, provides a higher fibre count per kilogram but lower stiffness. The result is that the polymer fibre engages at larger crack-opening displacements after first crack; it is therefore evaluated as residual flexural strength under ASTM C1609/C1609M-19a or EN 14651:2005+A1:2007 rather than as a direct modulus-for-modulus replacement for steel. The product is classified as a Type III synthetic macrofiber under ASTM C1116/C1116M. Compared with micro-synthetic polypropylene fibres used for plastic shrinkage control, which typically have lengths below 30 mm, the 54 mm twisted bundle is designed to bridge macro-cracks after hardening. Compared with fibrillated macro-synthetic fibres, the twisted bundle remains intact under high-shear mixing; the helical profile resists pull-out through a bearing mechanism against the surrounding cement paste. This reduces fibre-length degradation in twin-shaft compulsory mixers and truck-mixer drums and yields a more consistent fibre distribution in the hardened concrete. Compared with steel fibres, the product does not require minimum concrete cover for corrosion protection and does not produce surface rust stains.
Declared product data and associated test methods are listed in Table 1.
| Parameter | Declared value | Normative reference |
|---|---|---|
| Fibre class | Class II macro-synthetic | EN 14889-2:2006 |
| Material | Virgin polypropylene | ASTM C1116/C1116M Type III |
| Length | 54 mm | Manufacturer certificate of analysis |
| Specific gravity | 0.91 g/cm³ | ISO 1183-1:2019 |
| Tensile strength | 450 MPa | ISO 527-1:2019 |
| Tensile modulus | 5,000 MPa | ISO 527-1:2019 |
| Melting point | 165 °C | ISO 3146 |
| Water absorption | ≤0.1 % | ASTM D570 |
At 2.0 kg/m³, SikaFiber 540 Twist has a measurable effect on plastic shrinkage crack formation, although post-crack residual strength is generally low; early-age performance is more reliably quantified by ASTM C1579/C1579M or equivalent plastic shrinkage test methods. At 4.0–6.0 kg/m³, residual flexural strength and crack-width control become the primary design parameters. The applicable test methods are ASTM C1609/C1609M-19a for beam flexural performance and EN 14651:2005+A1:2007 for notched beam post-crack strength. Because the fibre is lower in modulus than steel, the post-crack response is characterised by load retention at increasing deflection, not by a sharp yield plateau. Mix design variables that affect bond include supplementary cementitious materials, water-cement ratio, and aggregate angularity. A concrete with a characteristic compressive strength class between C25/30 and C35/45 is commonly used in field trials, but the residual strength of this specific product must be verified for each aggregate source and cement type. Published data for the exact residual strength of SikaFiber 540 Twist in all concrete classes is limited; project-specific trial batching under the relevant flexural standard is therefore required before the fibre is substituted for welded wire mesh in a load-bearing slab design. At dosages above 6.0 kg/m³, workability loss and fibre balling can increase without a proportional improvement in residual strength, and batching trials above this range are not recommended without high-range water-reducing admixtures and mixing-time verification.
Field handling in ready-mix plants indicates that pump line blockages can occur when the 54 mm fibre is combined with aggregate top sizes above 20 mm and slump values below 120 mm. A typical horizontal concrete pump with a 125 mm nominal delivery line can convey the product at dosages up to 6.0 kg/m³ when the fresh concrete slump is held between 140 mm and 180 mm; the actual limit depends on pumping distance, vertical rise, and aggregate shape. Worn truck-mixer spiral blades reduce the tumbling action required for fibre dispersion and have been observed to produce clumps in the discharged concrete. Visual inspection after discharge should identify no fibre balls larger than 25 mm. During finishing, power-float operations should be delayed until the near-surface concrete has stiffened sufficiently to resist fibre uplift; early floating can draw fibres to the surface. In hot, windy conditions, a surface evaporation retarder or extended-set admixture may be used to manage the finishing window. Because the fibre is non-conductive, it does not interfere with embedded induction loops or radio-frequency identification systems used in industrial floors.
Mixer type influences fibre addition sequence. In a twin-shaft compulsory mixer with worn paddles, direct discharge of fibre bags at the start of dry mixing can wrap fibres around paddle arms; plant-scale observations indicate that adding the fibre after 50 % of the aggregate charge and before cement reduces this effect. Planetary mixers used in precast operations can accept the full dosage without opening the bag if the fibre is introduced during the final 30 seconds of dry aggregate mixing. In truck-mixer operations, the fibre should be charged at the plant, not on site, because the lower shearing action of a truck drum requires the extended 4–5 minutes wet mixing to separate bundles. If the fibre is added to a hot concrete load, the twisted bundles can soften locally at temperatures above 60 °C, even though the polypropylene melt point is 165 °C; this softening does not destroy the fibre but can alter bundle separation. Chilled mixing water is not required for macrofibre addition.
In ground-supported industrial floor slabs, the substitution of light-gauge welded wire mesh by SikaFiber 540 Twist is typically evaluated at a dosage of 4.0–6.0 kg/m³. The fibre is distributed throughout the full depth during mixing, while welded wire mesh can be displaced toward the bottom during placing unless adequate chairs and walkways are used. This positional failure mode is eliminated by macrofibre addition. However, the fibre does not provide the same restraint across saw-cut contraction joints as continuous steel mesh, and joint activation must be assured by saw-cutting within 24 hours in normal hardening conditions. The product does not replace dowels, load-transfer devices, or structural reinforcement at joints in pavements. The design should distinguish between crack-width control, where macrofibre use is accepted on the basis of residual flexural performance, and primary structural flexural reinforcement, where the fibre is not a direct substitute unless explicitly confirmed by the structural designer. Pre-construction field trials are specified to measure residual strength and plastic shrinkage cracking with the actual batching, pumping, and finishing equipment. Published data for this product in elevated slabs is limited, and SikaFiber 540 Twist is not intended as negative moment reinforcement over supports.
In precast non-structural elements such as façade panels, utility vaults, and paving slabs, the dosage is commonly set at 2.0–4.0 kg/m³ to improve handling integrity and secondary crack control. The fibre can be used in self-compacting concrete at lower dosage rates, generally near 2.0 kg/m³; the fresh-concrete spread flow should be verified by EN 12350-8:2019. Higher dosages increase plastic viscosity and reduce passing ability through congested reinforcement. In wet-cast plants using pan mixers, fibre addition should occur after the coarse aggregate and before the cementitious powder to reduce segregation. Quality control records should retain the fibre delivery documentation against the mix design. Batch-to-batch variation in fibre length is controlled within ±2 mm of the nominal 54 mm, and tensile strength variation is stated on the manufacturer’s certificate of analysis. The product should be stored dry and protected from prolonged direct sunlight; storage above 40 °C can deform the fibre bundles. Small amounts of surface moisture do not affect dispersion because the polypropylene fibre is hydrophobic. Factory production control is aligned with EN 14889-2:2006, and the user should verify the declaration of performance for the fibre class, length, and tensile properties before accepting delivered material.