| HS Code | 115046 |
| Material | Polypropylene |
| Fibertype | Macro synthetic |
| Length | 50 mm |
| Diameter | 0.8 mm |
| Aspectratio | 62.5 |
| Tensilestrength | 650 MPa |
| Elasticmodulus | 10 GPa |
| Density | 0.91 g/cm³ |
| Meltingpoint | 160 °C |
| Ignitionpoint | >400 °C |
| Alkaliresistance | Excellent |
| Waterabsorption | Nil |
| Dosage | 3-9 kg/m³ |
| Packaging | 10 kg bags |
| Shelflife | 5 years |
| Storage | Dry, protected from direct sunlight |
| Colour | Grey |
| Electricalconductivity | No |
| Magnetic | No |
As an accredited SikaFiber Force 650 - Structural Macro Synthetic Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged in 5 kg moisture-resistant bags, SikaFiber Force 650 structural macro synthetic fiber is supplied for concrete reinforcement. |
| Container Loading (20′ FCL) | SikaFiber Force 650 structural macro synthetic fibers loaded in a 20-foot FCL, palletized, shrink-wrapped, and secured for export. |
| Shipping | SikaFiber Force 650 – Structural Macro Synthetic Fiber ships as a non-hazardous, non-flammable solid in sealed bags on pallets. It has no UN number or dangerous goods classification. Store dry, away from sunlight and moisture. Follow local regulations, SDS, and standard dust-control PPE. |
| Storage | Store SikaFiber Force 650 in its original, unopened packaging in a cool, dry, well-ventilated area. Protect from moisture, direct sunlight, heat, and ignition sources. Keep away from incompatible chemicals and contaminants. Do not store outdoors unprotected. Maintain clean, level storage; stack pallets securely to prevent damage or collapse. Use first-in, first-out inventory rotation and observe manufacturer shelf-life and handling instructions. |
| Shelf Life | Shelf life is 24 months from production date when stored dry, in original unopened packaging, protected from direct sunlight. |
SikaFiber Force 650, a structural macro synthetic fiber conforming to EN 14889-2:2006, is added to central-mix concrete for ground-supported industrial floor slabs where automated logistics equipment, very narrow aisle racking, and high-bay pallet handling impose post-crack load-transfer requirements at construction joints. For this scenario the governing compliance framework is Concrete Society TR34 for modern concrete industrial floors, with fiber specification to EN 14889-2:2006 and routine performance testing by ASTM C1609/C1609M or EN 14651:2005+A1:2007. Addition rates are specified between 3.0 kg/m³ and 6.0 kg/m³, with the lower bound used for lightly loaded warehousing and the upper bound selected when saw-cut joint spacing is extended beyond 7.5 m or when racking leg loads exceed 120 kN in high-bay storage. The production process on a ready-mix plant commences with dry charging of the fiber into the aggregate weigh hopper; a twin-shaft compulsory mixer of 4.5 m³ batch capacity is used, with fiber and aggregate blended for 30–45 seconds before cementitious materials and free water are introduced. Mixing is continued at 18–22 rpm for a further 90 seconds after final water addition, and the fresh concrete is discharged from the plant at 150 ± 30 mm slump. Concrete is then conveyed by truck-mounted boom pump through 150 m of 100 mm-diameter delivery line to a laser screed, where it is struck off and compacted without poker vibration. Finishing uses a ride-on power trowel with 900 mm blade pans; the number of high-float and trowel passes is limited because excessive surface work can align fibers near the surface and produce a fuzzy, noncompliant texture. The terminal finished product is a 150–200 mm-thick jointless or long-panel internal slab used in automated distribution centres, cold stores, and e-commerce fulfilment hubs. A field-processing boundary is that fiber packages must be kept dry before charging; polyolefin macro fiber does not require pre-drying, but packaging stored at ambient relative humidity above 60% may introduce free moisture into the hopper and promote fiber clumping around mixer shafts, which has been observed to reduce residual flexural performance during batch-level EN 14651 verification.
In underground rock support and NATM/SEM tunnel excavation, the use of SikaFiber Force 650 in wet-mix sprayed concrete is governed by EN 14487-1:2005 for sprayed concrete specification, with fiber conformity to EN 14889-2:2006 and acceptance testing through EN 14488-3:2006 or ASTM C1550 round panel toughness. The typical addition range is 4.0–8.0 kg/m³, with the lower limit suitable for temporary support and the upper limit specified where permanent single-shell lining requires high post-crack energy absorption. Production data from tunnel batching plants indicate that addition above 5.5 kg/m³ raises the plastic viscosity of the wet mix sufficiently that high-range water reducer must be adjusted upward to maintain a pumpable slump of 180 ± 30 mm. The concrete is batched in a mobile twin-shaft mixer, transported in agitator trucks at 6–10 rpm, and charged into a D-valve piston pump; delivery to the nozzle occurs through a 50 mm inner-diameter hose at concrete output rates of 8–12 m³/h. At the nozzle, compressed air at 7–10 bar and alkali-accelerator dosed at 3–6% by cement weight are injected. Spraying is performed by a remote-controlled manipulator with 8 m reach, producing layers of 75–150 mm in a single pass. The terminal product is the primary or permanent stabilization lining of a tunnel, including intersections, cross-passage portals, and slope protection walls. Operational boundary: fiber length should not exceed one-half of the hose inner diameter, and hose couplings with internal steps must be avoided because they create turbulence that can orient fibers longitudinally and reduce round panel energy absorption. Published data for this product-specific shotcrete pump configuration above 200 m pumping distance is limited; trial spraying is required before main production.
Wet-cast box culverts, manhole base sections, and headwall units represent a precast concrete application in which short demolding windows and crane handling create localized impact loads at corners and lifting anchors. The relevant compliance standards are EN 13369:2018 for common rules for precast concrete products, EN 1916:2002 for concrete pipes and fittings where applicable, and EN 206:2013+A2:2021 for concrete specification; the fiber itself must conform to EN 14889-2:2006. SikaFiber Force 650 is added at 2.0–4.0 kg/m³ in wet-cast self-compacting or high-slump mixes; the upper band is selected for thin-walled sections below 150 mm or for units lifted with two-point chain systems that impose torsional shock. Production begins in a planetary counter-current mixer of 1.5 m³ batch capacity, where fiber is added to the aggregate before water and mixed for 60 seconds at 30 rpm to avoid fiber balls in the flowing paste. The fresh concrete is placed into steel moulds with external form vibrators operating at 45–60 Hz; the unit is cured at 20 ± 2 °C and 95% relative humidity and demolding occurs at 16 ± 2 hours when the surface compressive strength exceeds 15 N/mm² by rebound hammer correlation. The terminal finished product is an unreinforced or lightly reinforced box culvert segment, manhole base slab, or headwall unit for drainage infrastructure. A process constraint exists in dry-cast pipe production, where published data for SikaFiber Force 650 in zero-slump compaction is limited; wet-cast placement with external vibration is preferred for uniform fiber distribution.
In port container yards and intermodal freight terminals, SikaFiber Force 650 is dispersed into C30/37 or C40/50 pavement-grade concrete to provide residual post-crack capacity at slab corners subjected to eccentric loads from reach stackers, empty container handlers, and straddle carriers. The governing standards are EN 206:2013+A2:2021 for concrete specification, ASTM C1116/C1116M for Type III fiber-reinforced concrete, and ACI 360R for slab-on-ground design; performance validation uses ASTM C1609/C1609M beam testing. The addition range is 3.0–6.0 kg/m³, with the upper bound applied where wheel contact pressures exceed 600 kPa and where joint spacing greater than 6.0 m is required to reduce joint maintenance. Production uses a central mix or pugmill continuous plant with automated fiber dosing into the aggregate stream; the concrete is transported in truck agitators at 8–12 rpm and placed by slipform paver at a maximum advance speed of 1.2 m/min. Compaction is achieved through high-frequency screed vibrators integrated in the paver, and the slab is screeded to a thickness of 200–250 mm. Saw-cut contraction joints are executed between 6 and 12 hours after final set, depending on ambient temperature and surface evaporation rate, and diamond grooving at 15–25 mm depth is applied to container wheel paths. The terminal product is a heavy-duty concrete pavement for loaded container storage blocks, reach stacker lanes, and gate queues. An operational boundary is that macro synthetic fiber does not replace dowels at construction joints under heavy steel-wheel loads; joint load-transfer design still requires dowel bars or plate dowels.
| Application context | Primary compliance standard | Typical addition | Performance test method |
|---|---|---|---|
| Ground-supported industrial floors | EN 14889-2:2006; TR34 | 3.0–6.0 kg/m³ | ASTM C1609/C1609M; EN 14651 |
| Wet-mix tunnel shotcrete | EN 14487-1:2005; EN 14889-2:2006 | 4.0–8.0 kg/m³ | EN 14488-3:2006; ASTM C1550 |
| Precast box culverts and headwalls | EN 13369:2018; EN 1916:2002 | 2.0–4.0 kg/m³ | EN 14651; maturity-correlated demold checks |
| Port and intermodal pavements | EN 206:2013+A2:2021; ACI 360R | 3.0–6.0 kg/m³ | ASTM C1609/C1609M |
| Agricultural slurry and biogas aprons | EN 206:2013+A2:2021; EN 14889-2:2006 | 3.0–5.0 kg/m³ | EN 14651; abrasion testing under XM2 |
| Composite steel deck toppings | EN 1994-1-1; EN 14889-2:2006 | 1.8–4.0 kg/m³ | ASTM C1609/C1609M where specified |
Agricultural slurry channels, silage clamp aprons, and biogas feedstock receiving pads require concrete with resistance to organic acids, sulfate-containing effluents, and frequent scraping by front-end loaders. The compliance framework combines EN 206:2013+A2:2021 exposure classes XA3 for chemically aggressive agricultural liquid and XM2 for abrasive machine traffic, with fiber conformity to EN 14889-2:2006. SikaFiber Force 650 is blended at 3.0–5.0 kg/m³; the lower end is used for scrape-only floor areas and the upper end for slurry channel walls where hydraulic pressure and impact from tractor-mounted agitators create severe crack-opening conditions. The mix is produced in a twin-shaft mixer with a water-cement ratio not exceeding 0.42, a minimum cement content in line with XA3 requirements, and a slump of 120 ± 20 mm to permit long-panel placement without excessive bleeding. Placement is by laser screed or power roller, and saw-cut joints are eliminated or spaced beyond 12 m to reduce ingress points for slurry. The terminal product is a monolithic concrete apron or channel lining in dairy, piggery, and anaerobic digestion facilities. A limitation is that the fiber should not be combined with air-entraining admixtures targeted above 6% total air because the resulting air-void network at the fiber interface can reduce residual flexural toughness under repeated scraping loads.
For elevated composite floor slabs cast onto trapezoidal steel deck profiles, SikaFiber Force 650 is dispersed in pumpable C30/37 topping concrete at 1.8–4.0 kg/m³ to control plastic shrinkage cracks and increase toughness during construction traffic. The composite decking compliance standard is EN 1994-1-1, with fiber conformity to EN 14889-2:2006 and optional performance testing under ASTM C1609/C1609M where a specified residual flexural strength class is required by the structural engineer. The production process starts in a dry batch plant with fiber added to the aggregate weigh hopper before water; after mixing, the concrete is pumped through 65 mm-diameter steel delivery lines to the deck at a placement thickness of 120–150 mm. The fresh concrete is struck off with a portable screed rail, bull-floated, and finished with a walk-behind power float under low speed to minimize fiber exposure. The terminal product is a level composite slab in mezzanine, automated picking, and multi-storey logistics facilities. Operational boundary: macro synthetic fiber does not replace welded wire fabric where longitudinal shear resistance is required by EN 1994-1-1 clause 9.7.1; shear connectors and any additional mesh remain separate structural elements. Published data for this specific fiber in trapezoidal deck composite slabs is limited, therefore a preconstruction test panel is specified to verify surface finish and compaction around shear connector zones.
Competitive SikaFiber Force 650 - Structural Macro Synthetic Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber Force 650 – Structural Macro Synthetic Fiber is a polymer-based macro synthetic reinforcement used in structural concrete and shotcrete where distributed post-crack reinforcement, toughness, and crack-width control are specified as performance requirements. The product is classified under ASTM C1116/C1116M as a Type III synthetic fiber and is commonly supplied in a 65 mm cut length. Manufacturer-published data list a specific gravity of 0.91, tensile strength not less than 550 MPa, zero water absorption, and a recommended addition rate between 3 kg/m³ and 9 kg/m³. The product is non-absorbent and is evaluated in concrete matrices using residual-strength standards such as ASTM C1399/C1399M, ASTM C1550, and EN 14651. In contrast to welded wire mesh and steel fibers, SikaFiber Force 650 is dispersed throughout the cementitious matrix without the need for placement tolerance control or cover distance for corrosion protection.
Specification conformance is verified through ASTM C1116/C1116M Type III classification, which addresses synthetic macro fibers intended for structural load-bearing contribution. The fiber length of 65 mm places the product in the macro fiber category; the collated bundle geometry permits dispersion under normal concrete mixing rather than requiring pre-opening. The published specific gravity of 0.91 affects volumetric proportioning: at a dosage of 3 kg/m³, the added fiber volume is approximately 3.3 L/m³, while at 9 kg/m³ the added volume is approximately 9.9 L/m³. The tensile strength value of not less than 550 MPa is a fiber property; post-crack concrete performance is governed by the fiber-matrix bond, fiber aspect ratio, and dosage rather than by fiber tensile strength alone. Water absorption of 0% by mass means the fiber addition does not remove free water from the fresh concrete mixture.
| Parameter | Published value |
|---|---|
| Fiber classification | Type III synthetic macro fiber under ASTM C1116/C1116M |
| Nominal cut length | 65 mm |
| Specific gravity | 0.91 |
| Tensile strength | Not less than 550 MPa |
| Water absorption | 0% by mass |
| Recommended addition rate | 3 kg/m³ to 9 kg/m³ |
| Relevant residual strength standards | ASTM C1399/C1399M, ASTM C1550, EN 14651 |
For performance verification, ASTM C1399/C1399M uses a cracked beam reloaded under third-point loading and calculates average residual strength from specified net deflection values. ASTM C1550 employs a round panel under central point load and measures energy absorption from the load-deflection response. EN 14651 uses a notched beam under three-point loading to derive limit-of-proportionality and residual flexural tensile strength values at crack mouth opening displacement values of 0.5 mm, 1.5 mm, 2.5 mm, and 3.5 mm. These test methods are not interchangeable; the selected method depends on whether the acceptance criterion is beam residual strength, panel toughness, or European design residual strength.
The primary functional distinction lies in post-crack load transfer. Steel fibers provide comparatively high stiffness because the elastic modulus of steel is approximately 200 GPa, but they introduce corrosion potential when crack paths reach exposed fiber surfaces, and their density increases transport and pumping demands. Micro synthetic fibers, typically with equivalent diameter below 0.3 mm, are used for plastic shrinkage crack reduction and are not classified as structural reinforcement; their post-crack residual strength after the cementitious matrix cracks is negligible. SikaFiber Force 650 occupies a different position: the fiber is non-corroding, lower in density than steel, and intended to provide controlled post-crack residual strength through distributed macro fiber reinforcement.
| Parameter | SikaFiber Force 650 | Steel fiber | Micro synthetic fiber |
|---|---|---|---|
| Primary function | Post-crack residual strength and toughness | Post-crack residual strength and toughness | Plastic shrinkage crack control |
| Typical dosage | 3–9 kg/m³ | 20–60 kg/m³ | 0.6–1.8 kg/m³ |
| Corrosion potential | None | High unless stainless | None |
| Density | 0.91 | 7.85 | 0.90–0.98 |
| Post-crack response | Design-dependent residual strength | Comparatively high stiffness at narrow crack widths | Negligible after first crack |
In structural design, the replacement of steel reinforcement with macro synthetic fiber requires the use of measured residual flexural parameters, not nominal fiber tensile strength. The designer should compare the required residual strength at relevant crack mouth opening displacement or deflection limits with the values obtained from EN 14651, ASTM C1399/C1399M, or ASTM C1550. Because macro synthetic fibers exhibit lower modulus than steel fibers, crack widths under sustained load may be larger at equivalent reinforcement dosage. Published data for this specific configuration is limited for applications involving long-duration flexural creep; project-specific testing is required where crack-width control at service load is the governing criterion.
In slabs on grade, addition rates are selected according to the specified residual flexural strength and joint geometry. Rates between 3 kg/m³ and 5 kg/m³ are commonly evaluated for moderate distributed loading, while rates above 5 kg/m³ are employed where higher post-crack toughness or impact resistance is required. The elimination of welded wire mesh removes the placement tolerance requirement at the upper third of the slab and removes a corrosion plane at crack locations. For acceptance testing, beam specimens under ASTM C1399/C1399M or round panel specimens under ASTM C1550 are typically specified; the selection must align with the design model and the construction loading condition.
In shotcrete, the product is introduced in wet-mix or dry-mix equipment. The 65 mm cut length requires nozzle pressure and accelerator dose calibration during preconstruction trials because fiber rebound and sagging are sensitive to mix viscosity, air volume, and spray distance. Round panel toughness testing under ASTM C1550 is frequently used for tunnel and slope stabilization acceptance. A critical processing boundary is that high-rebound fiber loss can alter the in-place dosage from the batched dosage; therefore, sprayed panels should be cored or panel-tested at the start of production to confirm that the delivered fiber volume meets the design intent.
In precast concrete, the fiber can be used as distributed reinforcement when the element design incorporates the measured residual tensile response. Published data for this specific configuration is limited for thin-walled or highly reinforced sections; proof testing with production concrete and production curing conditions is required before the fiber is accepted as the sole secondary reinforcement. The product is not a direct replacement for primary flexural reinforcement unless the design explicitly uses residual strength parameters and accounts for the lower modulus of the synthetic macro fiber system.
Batching of SikaFiber Force 650 on production-scale equipment is performed with automated fiber dosing systems discharging against the falling aggregate stream. The fiber should be added after aggregate charging to permit mechanical opening of the collated bundles; unopened bundles may remain visible in low-mobility concrete. Mixing time after fiber addition should be limited to the minimum required for homogeneous distribution. Production-scale failure modes observed on actual manufacturing lines include fiber balling in high-shear mixers when dosing is introduced before aggregate, clumping at hopper transfer points, and localized dosage variation from manual bag addition. These are managed through automated dosing, sequential charging, and routine visual inspection of discharged concrete.
Adjustments to fresh concrete slump should be made with high-range water reducers, not with extra water, to avoid violating water-cementitious ratio limits. Compatibility with air-entraining admixtures must be verified because fiber surfaces can alter air-void coalescence and spacing factor. The product is non-absorbent and does not require pre-wetting; storage should be protected from direct sunlight and temperatures above 80 °C to prevent fiber bundle distortion. Addition rates above 9 kg/m³ may require mixer capacity and workability assessment because the added fiber volume can reduce slump and increase plastic viscosity beyond the range acceptable for conventional pumping and finishing.