| HS Code | 673851 |
| Material | Polypropylene |
| Type | Synthetic macro fiber |
| Form | Monofilament |
| Color | Natural |
| Length | 52 mm |
| Diameter | 0.9 mm |
| Aspect Ratio | 58 |
| Density | 0.91 g/cm³ |
| Tensile Strength | 540 MPa |
| Elastic Modulus | 9.5 GPa |
| Elongation At Break | 15% |
| Melting Point | 160 °C |
| Alkali Resistance | Excellent |
| Acid Resistance | Excellent |
| Water Absorption | Nil |
| Typical Dosage | 2-8 kg/m³ |
| Packaging | 5 kg bags |
As an accredited SikaFiber Force PP-540/52 - Synthetic Macro Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber Force PP-540/52 packaging: 600 g water-soluble bags, 20 bags per 12 kg carton, ready for direct mixer addition. |
| Container Loading (20′ FCL) | Container loading: palletized SikaFiber Force PP-540/52 synthetic macro fibers, stretch-wrapped, secured, evenly distributed in a 20′ FCL for ocean transport. |
| Shipping | SikaFiber Force PP-540/52 is a non-hazardous synthetic polypropylene macro fiber. It is not classified as dangerous goods for transport (no UN number). Ship in original sealed bags or cartons on pallets, keep dry, avoid punctures, and handle as general cargo under normal conditions. Consult SDS for specific regulatory requirements. |
| Storage | Store SikaFiber Force PP-540/52 in its original, unopened packaging in a cool, dry, well-ventilated warehouse. Keep away from direct sunlight, moisture, heat sources, open flames, and incompatible chemicals. Protect bags from damage and contamination. Stack safely to prevent deformation. Store indoors, off the ground, and away from sharp objects. Rotate stock first-in, first-out. |
| Shelf Life | Shelf life: 24 months from production if stored in original, unopened packaging, dry conditions, protected from direct sunlight and moisture. |
Defined as a macro synthetic polypropylene/polyolefin fibre with a nominal length of 54 mm and an equivalent diameter of 0.52 mm, SikaFiber Force PP-540/52 is classified under EN 14889-2:2000 as a Class II macrofibre and under ASTM C1116/C1116M-10a as a Type III synthetic fibre. The resulting aspect ratio is 104. Published product data list a fibre density of 0.91 g/cm³, a melting point near 160 °C, and an alkali-resistant polyolefin base. The product is supplied in engineered bundles that separate under concrete mixer shear. No pre-drying of the fibre itself is required at relative humidity below 60%; however, storage must avoid direct ultraviolet exposure, sustained temperatures above 60 °C, and physical compaction. The downstream application zones below are restricted to cementitious matrices where macro synthetic fibres provide plastic shrinkage control, crack-width limitation, and post-cracking residual capacity.
Compliance path for slab-on-grade applications is EN 14889-2:2000 for CE marking under Regulation (EU) No 305/2011, together with ASTM C1609/C1609M-19a for flexural toughness. The reference beam for ASTM C1609/C1609M-19a is 150 mm × 150 mm × 500 mm with a span of 450 mm; residual strength is recorded at net deflections of L/600 = 0.75 mm and L/150 = 3.0 mm. In a warehouse slab of 200 mm thickness cast on a compacted granular sub-base, the macrofibre is added at 2.5 kg/m³ to 3.5 kg/m³ when the initial saw-cut joint spacing is extended from 4.5 m to 7.5 m. Batched in a twin-shaft compulsory mixer of 2.5 m³ capacity or a planetary pan mixer, the fibre is introduced after the coarse aggregate is wetted and before the final water and superplasticizer are added. The mixer is held at 18–20 rpm for 45–60 seconds after fibre addition to separate the bundles without destroying the monofilament geometry. Slump is typically maintained at 120 mm ± 30 mm according to EN 12350-2:2019. On the finishing line, power trowel operators lower the pan angle to less than 15° during the first two passes; steeper angles create surface fuzzing and exposed fibre ends. Terminal product is a jointless or long-jointed heavy-duty floor slab in which the macrofibre replaces light steel mesh for crack-width control under forklift racking loads. The product does not replace dowels at construction joints and does not replace structural steel reinforcement in suspended slabs designed with significant positive moment.
Wet-mix shotcrete for drill-and-blast tunnel support requires the product to pass through a 65 mm to 75 mm delivery hose at 8–12 m³/h output without blocking. The macrofibre is batched into the concrete at the plant in the range 4.0 kg/m³ to 6.0 kg/m³; at above 7.0 kg/m³, fibre balling has been observed in ready-mix truck drums and in the hopper of robotic spraying manipulators. The matrix is designed for a slump of 180 mm to 220 mm before accelerator addition, with a maximum aggregate size of 8 mm to 10 mm. Alkali-free accelerator is injected at the nozzle at 4% to 8% by cement weight, and the fibre must not be premixed with the accelerator because polymer-modifier interactions are not specified under EN 934-5:2007. Compliance for sprayed concrete is governed by EN 14487-1:2005 for specification and EN 14488-5:2006 for energy absorption capacity; the latter uses a 600 mm × 600 mm × 100 mm panel with central point loading and energy absorption measured up to 25 mm deflection. Published data for PP-540/52 at 5.0 kg/m³ in wet-mix shotcrete indicate energy absorption values between 600 J and 1,000 J depending on aggregate type and accelerator dose; values below 500 J at 25 mm deflection may fail intended tunnel lining classes in weak rock. The terminal product is a temporary or permanent shotcrete lining with controlled crack development during ground movement, applied in benches and top-head sections. The synthetic macrofibre does not corrode, so sprayed linings exposed to aggressive groundwater avoid steel-fibre corrosion; however, the lower elastic modulus of polyolefin macrofibre means that early-age ductility is not equal to steel-fibre-reinforced shotcrete under high-ground-stress squeezing conditions.
Tunnel segmental linings cast in a carousel plant with 25 moulds per revolution require a macrofibre that remains uniformly dispersed under high-frequency vibration at 50–60 Hz. Published data for PP-540/52 in precast concrete indicate dosing between 2.0 kg/m³ and 4.0 kg/m³ depending on the required post-cracking capacity. The fibre is added to a 0.75 m³ planetary pan mixer after the cement and aggregates are blended for 30 seconds; total mixing time is extended to 90 seconds to avoid fibre nests at the mould edges. Self-compacting precast matrices with a slump flow of 550 mm to 650 mm according to EN 12350-8:2019 have been used with this fibre, but field practice indicates a fines content of at least 380 kg/m³ is typically necessary to prevent fibre settlement during vibration. Steam curing at 60 °C for 6 hours does not distort the fibre due to the polymer melting point near 160 °C. Compressive strength development is assessed according to EN 12390-3:2019. The terminal products are tunnel segmental rings, box culverts, and cable troughs in which edge splitting and demoulding damage are controlled. The product is not a substitute for internal steel reinforcement in structural precast segments designed under Eurocode 2; the fibre functions as secondary crack control and surface-integrity reinforcement.
| Application segment | Typical fibre dosage | Primary test standard | Mixing/placement constraint | Terminal product |
|---|---|---|---|---|
| Jointless industrial floor slab | 2.5–3.5 kg/m³ | ASTM C1609/C1609M-19a | Power trowel pan angle below 15° | Crack-controlled slab replacing light steel mesh |
| Wet-mix shotcrete tunnel lining | 4.0–6.0 kg/m³ | EN 14488-5:2006 | Hose blockage risk above 7.0 kg/m³ | Temporary or permanent sprayed concrete lining |
| Precast segmental lining | 2.0–4.0 kg/m³ | EN 12390-3:2019 | Fines content at least 380 kg/m³ in SCC | Segments, box culverts, cable troughs |
| Composite steel-deck slab | 2.0–3.0 kg/m³ | ASTM C1609/C1609M-19a | Slump 200–240 mm for pump line | Mesh-free composite floor topping |
| Container terminal rigid pavement | 2.5–4.0 kg/m³ | EN 13877-2:2013 | Automatic fibre dispenser to avoid clumps | Jointed heavy-duty pavement |
In composite steel-deck floor construction, the concrete is pumped through a 125 mm boom pump line at 20–30 m³/h and placed to a thickness of 120 mm to 180 mm over trapezoidal steel sheeting. The macrofibre is dosed at 2.0 kg/m³ to 3.0 kg/m³ to control plastic shrinkage cracking and to replace welded wire mesh in the topping. Matrices are specified with a pumpable slump of 200 mm to 240 mm; the fibre is added in the batching plant and must be fully dispersed before the concrete enters the pump hopper. Because PP-540/52 is a polyolefin macrofibre, it does not rust, which is relevant in composite decks where surface mesh is positioned near the top and is vulnerable to corrosion at construction joints. Flexural toughness is verified by ASTM C1609/C1609M-19a, while the composite section itself is governed by EN 1994-1-1 for steel-concrete composite design. Published post-fire residual flexural data for this exact PP-540/52 fibre in steel-deck assemblies is limited; therefore, fire resistance ratings must not rely on the macrofibre alone. The terminal product is a composite floor slab with reduced mesh installation labour and improved early-age crack control in metal deck ribs. The macrofibre does not alter the shear-stud design, and stud welding through the fibre-containing concrete is not required because studs are fixed to the steel deck before concrete placement.
Reach stacker corner loads at container terminals may exceed 9.0 t per wheel, and rigid pavement slabs with insufficient edge reinforcement often fail by corner cracking before saw-cut joints are cut. Mix designs for a 250 mm C40/50 air-entrained concrete under this traffic incorporate 2.5 kg/m³ to 4.0 kg/m³ of PP-540/52 to control early thermal contraction and drying shrinkage before joint activation. The fibre is batched in a 3.0 m³ twin-shaft compulsory mixer with an automatic dispenser mounted over the aggregate weigh hopper; manual bale addition is avoided because whole-bale dumping has caused fibre clumps in the first 1.0 m³ of discharge. Air content is maintained at 4.5% ± 1.5% according to EN 12350-7:2019. The terminal product is a jointed rigid pavement or hardstanding in which the macrofibre replaces light steel fabric for edge-control reinforcement. Flexural performance is checked using ASTM C1609/C1609M-19a, and slab design follows EN 13877-2:2013 for concrete pavements. The macrofibre does not provide dowel action across contraction joints; joint load transfer must be secured by steel dowels or aggregate interlock.
For external precast retaining elements such as noise barriers, retaining wall panels, and transformer bunds, the early-age lift cycle governs fibre dosage. Panels are typically demoulded after 16 hours and lifted by two or four anchors, generating shrinkage and handling stress that creates edge hairline cracks in plain concrete. PP-540/52 is added at 1.5 kg/m³ to 3.0 kg/m³ in a 1.0 m³ high-shear pan mixer to improve tensile strain capacity at the green stage. The concrete matrix is usually C30/37 with a water-cement ratio of 0.45 to 0.50. Compliance is verified by EN 14889-2:2000 and precast product conformity to EN 13369:2023. The terminal products are retaining elements with reduced repair work after handling; the macrofibre is not intended to replace the main bending reinforcement. Because the fibre is hydrophobic, it does not absorb mixing water, which helps preserve the low water-cement ratio without adjusting mix moisture. Storage of the fibre must avoid temperatures above 60 °C and direct UV exposure for more than one construction season.
Competitive SikaFiber Force PP-540/52 - Synthetic Macro Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber Force PP-540/52 is a synthetic macro fiber supplied as embossed, collated bundles of a virgin polypropylene/polyethylene blend. The product is classified under ASTM C1116/C1116-M Type III and EN 14889-2:2006 Class II for polymer fibers in concrete. The nominal geometry consists of a length of 54 mm, an equivalent diameter of 0.52 mm, and an aspect ratio of 104. Reported physical data list a specific gravity of 0.91 g/cm³, a tensile strength of 600 MPa, and an elastic modulus of 9.0 GPa measured under ISO 527 conditions. The collated bundle disintegrates during mixing, yielding discrete filaments without requiring individual monofilament handling. Because the polymer is hydrophobic and electrochemically inert, the fiber does not participate in chloride-induced corrosion reactions and does not require minimum concrete cover for corrosion protection. The product is intended for concrete and mortar reinforcement where structural design credits post-crack residual strength or crack-width control, not for primary moment-resisting reinforcement.
Within EN 14889-2:2006, polymer fibers are divided into Class I microfibers and Class II macrofibers; Class II products are defined by a diameter greater than 0.3 mm and are used where post-crack performance is required. PP-540/52 meets the Class II geometry with a nominal diameter of 0.52 mm. Under ASTM C1116/C1116-M, Type III denotes synthetic fiber reinforcement for concrete, whereas Type I applies to steel fiber and Type II to glass fiber. The macrofiber classification is consequential because only macrofibers are credited with post-crack residual strength under ASTM C1609/C1609-M and EN 14651; microfibers are typically limited to plastic shrinkage control. For CE-marked projects, EN 14889-2:2006 requires initial type testing and factory production control under the System 1 attestation procedure described in Annex ZA. The product is therefore positioned as a crack-control and toughness-enhancing fiber, not as an equivalent substitute for conventional reinforcing bar or welded-wire fabric in primary moment-resisting sections.
Residual flexural performance is commonly measured on 150 mm × 150 mm × 500 mm beams at a span-to-depth ratio of 3:1 in accordance with ASTM C1609/C1609-M. The test records load-deflection response at net deflections of L/600 and L/150, where L is the clear span. Dosages from 3.0 kg/m³ to 5.0 kg/m³ typically yield measurable post-crack residual strength, with the reinforcing mechanism governed by frictional pullout and mechanical anchorage along the embossed fiber surface rather than chemical bond to cement paste. At the 0.52 mm equivalent diameter and 54 mm length, the fiber bridges cracks after matrix cracking and transfers stress across crack faces until pullout occurs. Crack widths that can be arrested under service loads are generally in the 0.2 mm to 0.5 mm range, depending on dosage, aggregate interlock, and slab thickness; published data for this specific configuration is limited for crack widths above 0.5 mm under cyclic loading.
Below 2.0 kg/m³, the fiber count is insufficient to stabilize macrocracks after the concrete reaches peak load; measured residual strength under ASTM C1609/C1609-M may be statistically indistinguishable from unreinforced control beams. Between 2.0 kg/m³ and 3.5 kg/m³, the fiber begins to influence crack propagation but the failure mode remains predominantly single-crack localization. Above 4.0 kg/m³, multiple cracking is more frequently observed in 150 mm deep beams, and the load-deflection curve transitions from deflection-softening to near-deflection-hardening behavior in some mixes. The transition is influenced by aggregate type, water-cement ratio, and beam depth; no single dosage value guarantees strain-hardening behavior. In full-depth slab sections, dosage may need to be increased to 5.0–6.0 kg/m³ when aggregate interlock is reduced by saw-cut joints spaced wider than 6 m. For high-performance concrete with water-cement ratios below 0.35, addition rates above 8.0 kg/m³ can raise mixing torque and reduce pumpability, and air content should be monitored under ASTM C231/C231-M.
| Parameter | Nominal value | Test basis |
|---|---|---|
| Fiber type | Synthetic macro fiber | ASTM C1116/C1116-M Type III; EN 14889-2:2006 Class II |
| Base polymer | Virgin polypropylene/polyethylene blend | Manufacturer batch data |
| Nominal length | 54 mm | Manufacturer QC caliper |
| Equivalent diameter | 0.52 mm | Manufacturer QC |
| Aspect ratio | 104 | Calculated |
| Specific gravity | 0.91 g/cm³ | ASTM D792 |
| Tensile strength | 600 MPa | ISO 527 |
| Elastic modulus | 9.0 GPa | ISO 527 |
| Melt temperature | 160 °C to 165 °C | DSC |
| Recommended dosage | 2.0 kg/m³ to 8.0 kg/m³ | Manufacturer technical data sheet |
For slab-on-grade applications, the manufacturer’s technical documentation lists a dosage band of 3.0 kg/m³ to 5.0 kg/m³ where post-crack residual strength is specified for concentrated racking loads. Lower addition rates of 1.5 kg/m³ to 2.5 kg/m³ may be used for crack-width control in lightly loaded internal slabs, but these rates do not produce measurable structural toughness under ASTM C1609/C1609-M. In wet-mix shotcrete, 4.0 kg/m³ to 6.0 kg/m³ is the common addition range, combined with a maximum aggregate size of 8 mm and silica fume at 5–10% by mass of binder to maintain pumpability through 50 mm inside diameter hoses. For precast facade panels, dosing at 2.0 kg/m³ to 3.5 kg/m³ reduces demolding damage but does not eliminate the need for lifting inserts and edge steel. All applications require preconstruction panels or trial batches because macrofibers alter the relationship between slump and placeability; a slump reduction of 20 mm to 40 mm is common at 4.0 kg/m³ and can be compensated with polycarboxylate ether superplasticizer.
In twin-shaft compulsory mixers with a nominal batch volume of 3.0 m³, the product is fed through a conveyor or bulk bag frame over 30–60 seconds. Paddle clearance below 25 mm can shear the polymer bundles prematurely before they disperse, resulting in fiber nests that accumulate on vibratory screens. In truck-mix operations, the addition rate should not exceed 10 kg/min for a 9 m³ drum to avoid wrapping around mixing drum fins; plant-specific calibration is required because drum fin geometry and wear vary. In central mixers, a wet mixing interval of 4–5 minutes at 10–15 rpm is used; for truck mixers, dispersion occurs over 6–8 minutes at 12–16 rpm. Batching records from slab-on-ground operations indicate that balling risk increases when concrete temperature is below 2 °C or above 35 °C, or when the nominal maximum aggregate size exceeds 25 mm. The theoretical fiber count is approximately 96,000 fibers/kg, calculated from the nominal equivalent diameter, length, and specific gravity. At 4.0 kg/m³, this supplies roughly 384,000 fibers/m³. Quality-control verification is conducted by washing out a known fresh concrete mass and comparing recovered fiber count against the charged weight; recovery below 95% of theoretical weight indicates incomplete bundle dispersion. No pre-drying of the polymer is required for sealed packaging, but bags stored at relative humidity above 60% for more than 30 days should be inspected for compaction of collapsed bundles before use.
Steel fibers within 20 mm of a slab surface may initiate corrosion staining and spalling when exposed to NaCl or CaCl₂ de-icing salts. PP-540/52 is electrochemically inert in alkaline pore solution and does not require cover to resist chloride-induced degradation. This property makes the fiber suitable for external slabs, loading docks, and parking decks where de-icing agents are present. The polymer is also resistant to sulfate exposure and dilute acids in agricultural floors, although the concrete matrix itself must be designed for the exposure class. Replacement of steel fibers should not be made on a one-to-one mass basis; steel fibers at 15–30 kg/m³ are commonly replaced by macro synthetic fibers at 3.0–5.0 kg/m³ for non-primary crack control and impact resistance, but the replacement ratio must be checked against the specified residual strength class in EN 1992-1-1 or ACI 544.4R.
| Property | PP-540/52 | Hooked-end steel fiber | Micro synthetic monofilament |
|---|---|---|---|
| Nominal length | 54 mm | 35 mm | 12 mm |
| Equivalent diameter | 0.52 mm | 0.55 mm | 0.02 mm |
| Specific gravity | 0.91 g/cm³ | 7.85 g/cm³ | 0.91 g/cm³ |
| Tensile strength | 600 MPa | 1,100–1,500 MPa | 300–400 MPa |
| Elastic modulus | 9.0 GPa | 210 GPa | 3.5–4.5 GPa |
| Corrosion response | Inert in chloride and sulfate | Corrodes if cracks exceed 0.2 mm | Inert |
| Post-crack residual strength | Achieved at 3.0–5.0 kg/m³ | Achieved at 15–30 kg/m³ | No measurable structural toughness |
| Theoretical fiber count per kg | 96,000 fibers/kg | 3,000 fibers/kg | Approximately 100 million fibers/kg |
Compared with shorter synthetic macrofibers, the nominal length of 54 mm is near the upper practical limit for pumped concrete with 20 mm maximum aggregate; 65 mm fibers are often limited to extruded concrete and slabs with 25 mm aggregate. The 0.52 mm equivalent diameter creates a balance between individual fiber stiffness and surface area; fibers below 0.3 mm diameter may be too flexible to provide residual strength, while fibers above 0.7 mm diameter can reduce workability and finishability at high dosage. The embossed surface texture differentiates PP-540/52 from smooth monofilament macrofibers by increasing frictional pullout resistance, which can translate to higher residual strength at the same dosage. This difference is measurable under ASTM C1609/C1609-M when comparing residual flexural strength ratios at 4.0 kg/m³; smooth fibers may show lower values because pullout occurs before substantial fiber engagement.
Admixture compatibility is defined by the polymer’s inert surface chemistry. The fiber does not interfere with polycarboxylate ether, lignosulfonate, or naphthalene sulfonate plasticizers. When air entrainment is required, the air-entraining admixture dose may require adjustment of 10–20% because hydrophobic fiber surfaces can destabilize the air void system during extended mixing. The product is not recommended for structural members where fire resistance depends on post-fire fiber contribution; the polypropylene/polyethylene matrix softens near 160 °C, leaving localized voids after fire exposure. In composite steel deck slabs, fire resistance should be evaluated under UL 263 or EN 1365-2 using the specific fiber dosage because published data for this specific configuration is limited. The fiber is not intended for use in prestressed concrete, post-tensioned ducts, or as the sole reinforcement in suspended slabs without conventional reinforcing steel. For low-temperature applications, the polymer retains flexibility below -30 °C, but mixing and placing below -5 °C should follow cold-weather concreting procedures in ACI 306R.