| HS Code | 774708 |
| Productname | SikaFiber Force PP-55/RAD55s |
| Fibertype | Macro Structural Synthetic Polypropylene Fiber |
| Material | 100% virgin polypropylene |
| Color | Natural |
| Length | 55 mm |
| Equivalentdiameter | 0.85 mm |
| Aspectratio | 65 |
| Tensilestrength | 550 MPa |
| Elasticmodulus | 6 GPa |
| Density | 0.91 g/cm³ |
| Meltingpoint | 160 °C |
| Ignitionpoint | >400 °C |
| Alkaliresistance | Excellent |
| Waterabsorption | Nil |
| Dosage | 4-9 kg/m³ |
| Packaging | 20 kg bags |
| Shelflife | 24 months |
| Standardcompliance | EN 14889-2 Class II; ASTM C1116 Type III |
As an accredited SikaFiber Force PP-55/RAD55s - Macro Structural Synthetic Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 5 kg moisture-resistant bags, 40 bags per pallet (200 kg total), labeled SikaFiber Force PP-55/RAD55s macro synthetic polypropylene fiber. |
| Container Loading (20′ FCL) | SikaFiber Force PP-55/RAD55s in 20′ FCL dry container: palletized bags, evenly distributed, secured, moisture-protected, labeled, compliant with shipping regulations. |
| Shipping | SikaFiber Force PP-55/RAD55s ships as a non-hazardous, non-regulated macro synthetic polypropylene fiber in moisture-resistant bags on pallets. Use dry, covered transport; protect from moisture, UV, and punctures. No DOT/IMDG/IATA placards required. Store at moderate temperatures; handle with standard PPE and avoid dust generation. It is not classified as dangerous goods. |
| Storage | Store SikaFiber Force PP-55/RAD55s in original, unopened, sealed packaging in a dry, cool, well-ventilated area. Keep pallets off the floor, away from direct sunlight, heat, sparks, flames, and moisture. Protect bags from tearing or puncturing. Maintain good housekeeping to minimize dust; use appropriate PPE when handling. Shelf life may be reduced by prolonged UV exposure or damp conditions. |
| Shelf Life | Shelf life: 24 months from production date when stored in original, unopened packaging, dry, protected from direct sunlight and moisture. |
SikaFiber Force PP-55/RAD55s macro structural synthetic polypropylene fiber is introduced at the dry aggregate charging stage in precast segmental lining production for mechanised tunnel ring fabrication. The mixing sequence in a twin-shaft compulsory mixer or high-shear counter-current pan mixer requires the fiber to be dispersed before water and superplasticizer are added, because polypropylene macro fibers with a nominal length of 55 mm can form transient agglomerates if dosed onto wet aggregate surfaces. A dosage window of 5.5–7.0 kg/m³ is typically selected for segmental linings exposed to TBM thrust jack loads and vacuum lifting demoulding stresses; below 4.5 kg/m³, the post-crack residual flexural strength measured by EN 14651:2005+A1:2007 or ASTM C1609/C1609M-19 may not provide the required toughness for ring build and annular grouting pressure, while above 7.5 kg/m³ the low-slump mix can develop elevated yield stress that slows mould filling and reduces compaction under external vibration. Compliance for CE-marked supply under Construction Products Regulation 305/2011 is established through EN 14889-2:2006 Class II for macro synthetic fibers, with initial type testing covering fiber tensile strength, alkali resistance, and effect on concrete strength; the Declaration of Performance must list fiber geometry, dosage class, and tested concrete performance. ACI 544.4R-18 and project specifications derived from EN 1992-1-1 provide the design basis for substituting steel fiber or welded wire mesh reinforcement in precast segments, but structural qualification is performed on full-scale panels because fiber orientation at the formwork face is not homogeneous; ASTM C1550-20 or EN 14488-4 may be used depending on element geometry. Production parameters include a water/cement ratio of 0.32–0.36, a total mixing time of 120–150 s after fiber addition, and formwork filling through multiple vibrator arrays operating at 50–100 Hz to avoid fiber balling. Steam curing at 55–60°C for 8–12 h produces demoulding compressive strengths above 12–15 MPa, after which the segments are vacuum-lifted into segment trailers and transported to the TBM. Terminal product types include bolted precast concrete segmental rings with widths of 1,500–2,000 mm and thicknesses of 250–500 mm, shaft lining rings, cut-and-cover tunnel wall units, and box culvert segments where sulfate-resisting cement and low-permeability mix design are specified. Synthetic macro fibers do not replace the conventional reinforcing cage for bursting stresses around gasket pockets and connector bolts; they function as secondary toughness reinforcement and crack width control under transient handling and ring compression loads. Fiber packaging should be stored at relative humidity below 60% and protected from direct UV exposure; surface moisture above 0.02% by mass can impair auger or screw metering at the batching plant.
The governing limit for joint-free industrial slab geometry is the restrained shrinkage strain capacity of the concrete at the intersection of slab thickness, sub-base friction, and post-crack residual tensile strength. Polypropylene macro synthetic fiber at 3.0–5.0 kg/m³ is a common addition in warehouse slabs and high-bay racking floors, while 5.0–7.0 kg/m³ is reserved for reduced-joint layouts or floors carrying dynamic pallet traffic. ASTM C1581-04 quantifies the age of restrained shrinkage cracking, and specifications often require a crack-width reduction of at least 50% relative to plain concrete at a dosage of 4.0 kg/m³; published data for any given cement content and supplementary cementitious material ratio is limited, so qualification batches are required. ASTM C1609/C1609M-19 residual strength at net deflections of L/600 and L/150 is the primary North American toughness measure, while EN 14651:2005+A1:2007 fR1 and fR3 values are used for CE-marked supply. Compliance with EN 14889-2:2006 Class II is mandatory where the fiber is supplied in the EU; the chain of custody includes the notified body certificate, the Declaration of Performance, and batch traceability to the polypropylene resin lot. ACI 360R-10 governs slab-on-ground design and requires joint spacing, curling analysis, and saw-cut depth to be determined from slab thickness and sub-base friction, not from fiber dosage alone. Production uses ready-mix trucks with fiber dosed at the plant or on site; after fiber addition, 5–7 min of mixing at 12–18 rpm drum speed is standard, and the concrete is discharged through a laser screed with 3D automatic level control. The placement spread rate on large logistics slabs ranges from 1,200 to 2,500 m² per shift depending on pump delivery and screed width. A power trowel with pan floats and finish blades is used when bleed water has evaporated; early troweling can fold surface fibers into the paste, causing protrusion after hardening. Curing membranes conforming to ASTM C309 or water curing for 7 days after final set reduce plastic shrinkage and improve surface abrasion resistance. Terminal product types include high-bay racking floors for automated storage and retrieval systems, freezer slabs at −25°C to −30°C where macro fibers reduce brittle fracture risk, robot-operated mezzanine decks, and logistics cross-dock slabs. Macro synthetic fibers do not eliminate saw-cut joints entirely; they permit wider joint spacing or replace joint armoring in some designs, but drying shrinkage persists. The dosage should not be increased above 7.5 kg/m³ without re-verifying pumpability, because the yield stress increase at a fixed water/cement ratio can reduce laser screed efficiency and make finishability unacceptable under hot weather conditions.
| Application zone | Typical addition rate | Primary test standard | Typical terminal product |
|---|---|---|---|
| Precast segmental lining | 5.5–7.0 kg/m³ | EN 14651:2005+A1:2007; ASTM C1609/C1609M-19 | TBM ring segments, shaft liners |
| Industrial joint-free slab | 3.0–5.0 kg/m³ | ASTM C1581-04; ASTM C1609/C1609M-19 | Racking floors, logistics slabs |
| Wet-mix shotcrete | 4.0–7.0 kg/m³ | EN 14488-3:2006; ASTM C1116/C1116M-23 | NATM linings, slope stabilization |
| Port and intermodal pavement | 4.0–6.0 kg/m³ | ASTM C1550-20; ACI 330R-08 | Container yards, ro-ro ramps |
| Composite steel deck slab | 3.0–5.0 kg/m³ | ASTM C1609/C1609M-19; ANSI/SDI C-2011 | Steel-frame floor decks |
| Architectural precast panel | 1.8–3.0 kg/m³ | ASTM C1579-21; ACI 533R-11 | Cladding panels, noise barriers |
The wet-mix shotcrete process introduces a conflict between pumpable fresh concrete rheology and low-rebound sprayed concrete placement. Macro synthetic fiber with a nominal length of 55 mm at 4.0–7.0 kg/m³ raises the dynamic yield stress of the mix, and the pressure gradient across a 50 mm to 65 mm diameter delivery hose increases when the fiber dosage exceeds 7.0 kg/m³; in practice, blockages at the hose reducer, pumping elbow, or nozzle body occur when the coarse aggregate concentration is high and the air flow is below 7 m³/min. A twin-piston shotcrete pump with a hydraulically driven S-tube or rock valve is used for wet-mix application at line pressures of 20–40 bar, but the actual nozzle air pressure required for adequate compaction is 0.6–0.8 MPa with an air volume of 7–10 m³/min. Alkali-free liquid accelerator at 2–6% by weight of binder is introduced at the nozzle; the compatibility of the fiber with high-alkali or silicate accelerators must be checked because accelerator chemistry affects the fiber-matrix bond and early-age plasticity. Rebound on vertical and overhead surfaces is influenced by nozzle angle, distance, and layer thickness: a nozzle held at 90° to the receiving surface at a distance of 0.8–1.5 m reduces rebound, and each pass should be limited to 50–150 mm until the placed layer has developed sufficient shear strength. ACI 506R-16 provides the industry guidance for fibrous shotcrete, while EN 14487-1:2005 defines the sprayed concrete specification and EN 14488-3:2006 specifies the test method for fiber content in sprayed concrete. ASTM C1116/C1116M-23 covers fiber-reinforced concrete and shotcrete, and the toughness classes defined by ASTM C1609/C1609M-19 or panel energy absorption measured by ASTM C1550-20 are referenced for permanent rock support. Compliance under EN 14889-2:2006 Class II is required for the fiber itself; the installation quality is verified by fresh concrete slump according to ASTM C143/C143M or EN 12350-2, and hardened sprayed concrete cores are tested according to EN 12504-1 or ASTM C42. Because macro synthetic fibers can be lost in rebound, the specified dosage is not the same as the in-situ fiber content; the hardeners and inspectors should verify drilled core fiber count or wash-out testing on fresh sprayed material. The terminal products include NATM primary linings in hard rock and soft ground, slope stabilization and rockfall retention aprons, spillway channel linings, and underground mine development drifts where ground support is placed after blast rounds. The operational boundary appears when the aggregate moisture content exceeds the saturated-surface-dry condition by more than 1.0%, because free water in the aggregate changes the water/cement ratio and the pump pressure profile; aggregate stockpiles should be covered, and the batching moisture compensation must be updated every 4 h under changing weather conditions.
At container terminals and intermodal yards, continuously slipformed or fixed-form pavement concrete is subjected to rubber-tyred gantry crane wheel loads, reach stacker front-axle loads, and twist-lock point loads from stacked containers. Macro synthetic polypropylene fiber is dosed at 4.0–6.0 kg/m³ into a pavement mix with a water/cement ratio of 0.38–0.42 and a 28-day characteristic compressive strength of 40–50 MPa; the fiber functions as secondary crack control and impact toughness reinforcement, not as a substitute for dowels, tie bars, or joint load-transfer devices. ASTM C1550-20 round panel energy absorption and ASTM C1609/C1609M-19 residual strength are commonly specified for port pavements, while ACI 330R-08 provides the rigid pavement design methodology for industrial and commercial areas. Where European or Middle East projects are supplied, EN 13877-2 applies to concrete pavement layers, and the fiber is supplied with a Declaration of Performance under EN 14889-2:2006 Class II. Production uses a slipform paver with sideform compaction and automatic dowel insertion, or fixed-form placement with vibratory truss screeds; after fiber addition, the mix must remain workable for the full transit and placement window, and the air content of the fresh concrete is maintained at 4–6% for freeze-thaw exposure according to ASTM C231 or EN 12350-7. Terminal product types include container yard storage slabs, ro-ro ramp decks, crane runway foundations, intermodal rail transfer areas, and high-speed gate lanes at terminal entrances. The joint pattern remains the critical design feature: macro fibers can improve joint edge spalling resistance but do not eliminate the need for saw-cut contraction joints, and joint sealing materials must be compatible with the pavement surface hardener. At dosages above 6.0 kg/m³, the slipform paver steering control can become unstable if the concrete yield stress increases beyond the range calibrated for the paver sensors; therefore, site trials must confirm the mixture’s rheology at the full production dosage before placing main-line pavement.
Composite steel deck slabs in multi-storey steel-framed buildings are a special case where synthetic macro fiber replacement of welded wire mesh removes the lifting, staging, and fall hazard of mesh installation but changes the crack control mechanism at the negative moment region. The fiber dosage is typically 3.0–5.0 kg/m³ in normal-weight concrete with a slump of 140–180 mm, placed over profiled steel decking with a minimum flange width and deck thickness defined by ANSI/SDI C-2011. The mix is pumped through a placing boom to the deck, where the steel deck deflection under wet concrete and construction live load must not exceed the manufacturer’s limit, commonly 19 mm or L/180, and the concrete density of 2,300–2,400 kg/m³ must be included in the construction-stage deck load calculation. ASTM C1609/C1609M-19 or EN 14651:2005+A1:2007 provides the post-crack flexural performance data; ACI 544.4R-18 is used for the fiber-reinforced concrete design values, and EN 14889-2:2006 Class II governs CE-marked fiber supply. Eurocode 4 and the steel deck manufacturer’s test reports define the composite slab flexural and fire resistance, and the use of macro fibers in lieu of mesh requires that the fire engineering evaluation include the slab’s tensile membrane behavior at elevated temperatures. Production relies on a laser screed or manual screed rail, and the concrete is finished with a bull float; over-troweling is avoided because the macro fiber at the surface can create visible protrusion and reduce the bond of subsequent floor coverings. Terminal product types include composite floor slabs in steel office towers, residential high-rise buildings, hospital floors, and parking structure decks where the steel frame uses the composite action between the slab and the downstand beam. Macro fibers do not replace headed stud shear connectors; the stud spacing and shear capacity are determined by the steel deck configuration and the beam design, not by fiber dosage. If the deck is galvanized and the concrete contains calcium chloride accelerator, corrosion of the steel deck is a risk; accelerators should be non-chloride based and the total chloride content of the concrete must comply with the limits in EN 206:2013+A2:2021 or ACI 318-19.
Thin-walled architectural precast elements such as facade cladding panels, sandwich panel face shells, and acoustic barrier units carry wind loads, thermal bowing forces, and demoulding stresses through cross-sections often less than 100 mm thick. Macro synthetic polypropylene fiber at 1.8–3.0 kg/m³ is introduced into self-consolidating or high-slump precast concrete to reduce plastic shrinkage cracking and provide post-crack ductility during stripping, tilting, and transport. ASTM C1579-21 is used to evaluate plastic shrinkage cracking; ASTM C1609/C1609M-19 or EN 14651:2005+A1:2007 measures residual flexural capacity; and ACI 533R-11 provides guidance for architectural precast concrete. Compliance with EN 14889-2:2006 Class II is required for CE-marked fiber deliveries, and the concrete itself must satisfy EN 206:2013/A2:2021 exposure classes appropriate to the installation environment. Production uses stationary pan mixers or planetary mixers with precise fiber dosing; after fiber dispersion, the SCC mix must retain a slump flow of 650–750 mm with no segregation, and the filling of narrow mould profiles is verified by visual inspection of the form face after demoulding. The panels are demoulded at concrete strengths above 8–10 MPa, then cured under polyethylene sheeting or in a curing chamber at 20°C and 95% relative humidity for at least 7 days to minimize early-age shrinkage. Terminal product types include exterior facade cladding panels, sandwich wall panels, noise barrier panels, and decorative concrete louvers. Dosages above 3.5 kg/m³ are not typically specified for architectural surfaces because the fiber can become visible after acid etching or abrasive blasting; if a textured surface is required, the surface finish trial must be conducted using the full production dosage and the actual retarder or form liner combination.
Competitive SikaFiber Force PP-55/RAD55s - Macro Structural Synthetic Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber Force PP-55/RAD55s is a macro structural synthetic polypropylene fiber supplied as an engineered monofilament for concrete and sprayed concrete reinforcement. The designation identifies a nominal length of 55 mm and an embossed surface geometry intended to improve mechanical anchorage within cementitious matrices. The material is manufactured from virgin polypropylene with a published density of approximately 0.91 g/cm³, a nominal monofilament diameter near 0.85 mm, and a tensile strength reported in manufacturer data as 600 MPa to 650 MPa. The fiber is categorized under EN 14889-2:2006 as a Class II macro-synthetic fiber and under ASTM C1116/C1116M-10a as a Type III synthetic fiber for concrete reinforcement. Unlike steel fibers, the product is not subject to corrosion, does not produce rust staining at exposed surfaces, and reduces added mass compared with steel macro-fibers at equivalent fiber counts.
The reinforcement mechanism relies on crack-bridging across microcracks after the concrete matrix reaches its tensile strain capacity. When dosage is controlled between 3 kg/m³ and 9 kg/m³, depending on design requirements, the fiber network transfers tensile stress across crack faces and modifies the post-crack load-displacement response. Residual flexural strength is quantified by beam testing to EN 14651:2005+A1:2007; the limit of proportionality and residual flexural tensile strength values at crack mouth opening displacement values of 0.5 mm, 1.5 mm, 2.5 mm, and 3.5 mm are used in design verification. In ASTM-based practice, ASTM C1609/C1609M-19a third-point beam tests provide equivalent residual strength parameters at net deflections of L/600 and L/150. Published dosage-response data indicate that residual strength increases nonlinearly with fiber addition, but no universal design value can be assigned without a project-specific beam test because aggregate type, matrix strength, and mixing energy alter fiber orientation and distribution. Typical slabs-on-grade specify 4 kg/m³ to 6 kg/m³ for crack-width control and replacement of conventionally welded wire mesh in temperature and shrinkage reinforcement. Higher dosages of 7 kg/m³ to 9 kg/m³ may be justified for tunnel segments where toughness and impact resistance are required.
Comparative performance against steel macro-fibers is governed by the lower elastic modulus of polypropylene, typically 9 GPa to 10 GPa compared with approximately 200 GPa for steel. Consequently, synthetic macro-fibers generally require a higher volume fraction or different dosage to achieve equivalent residual strength in hardened concrete; however, the low density reduces added mass. At equal fiber count, a macro synthetic dosage of 4 kg/m³ to 6 kg/m³ can replace approximately 25 kg/m³ to 40 kg/m³ of steel fibers in non-structural crack-control applications, although structural replacement must be verified by design calculations and testing. The absence of corrosion allows placement at cover depths not permissible for steel fiber reinforced concrete exposed to chlorides. Compared with micro polypropylene monofilaments used for plastic shrinkage control at dosages of 0.6 kg/m³ to 1.5 kg/m³, the PP-55/RAD55s fiber has a larger diameter, higher stiffness contribution, and longer anchorage length, and is not a substitute for early-age plastic shrinkage reinforcement alone; the two fiber classes may be combined in the same concrete mixture.
The fibers are added to the concrete mixer after aggregates and before or during water addition, or directly into the truck drum at the plant. Uniform distribution requires wet mixing time compatible with the mixer type. Twin-shaft compulsory mixers with high-shear mixing generally disperse the fibers within 4 min to 5 min after fiber addition, while free-fall drum mixers may require longer, and batching fibers too rapidly can lead to balling at dosages above 6 kg/m³. Published production guidance recommends adding the bags under the aggregate stream or using fiber dosing equipment on continuous plants. Fiber clumping is an operational risk when early water demand is low or when the concrete slump is below 100 mm; high-range water-reducing admixtures may be needed to restore workability without increasing water-cement ratio. Field measurements on production lines indicate that macro synthetic fibers can reduce pump pressure relative to equivalent steel fiber dosages because the lower density and flexible nature reduce line packing, though 90-degree bends and hose reductions still require standard concrete pumping procedures.
Sprayed concrete applications with wet-mix equipment have used the fiber in dosages between 4 kg/m³ and 8 kg/m³ for temporary and permanent linings. In tunnel and slope stabilization work, the fiber reduces rebound mass compared with steel fibers in certain mix designs and removes the corrosion risk associated with steel fiber ends exposed at the sprayed surface. The product is compatible with alkali-free set accelerators and standard superplasticizers; published data for the specific interaction with high-dosage accelerator systems are limited, and spray trials should establish the accelerator dosage and early strength development using EN 14488-3:2006 or equivalent projectile penetration methods.
| Property | Typical Value | Test Method or Basis |
|---|---|---|
| Material description | 100% virgin polypropylene macro-fiber | Manufacturer’s specification |
| Specific gravity | 0.91 g/cm³ | ISO 1183-1:2019 |
| Nominal fiber length | 55 mm | Manufacturer’s optical measurement |
| Nominal monofilament diameter | 0.85 mm | Optical microscopy |
| Aspect ratio | Approximately 65 | Calculated length/diameter |
| Tensile strength | 600 MPa to 650 MPa | Manufacturer’s tensile test data |
| Elastic modulus | 9.5 GPa | ISO 527-1:2019 |
| Melt point | 160 °C to 165 °C | ISO 11357-3:2018 |
| Water absorption | <0.1% | ISO 62:2008 |
| Concrete fiber classification | Class II macro-synthetic | EN 14889-2:2006 |
| Concrete fiber type | Type III synthetic fiber | ASTM C1116/C1116M-10a |
Stored bags should be kept dry, below 50 °C, and away from direct ultraviolet exposure for prolonged periods. Minor moisture exposure does not degrade polypropylene, but wet bags can introduce clumping and affect batching accuracy. The fiber is not intended for replacement of primary structural reinforcement in beams, columns, or suspended slab flexural zones unless explicitly designed by a qualified engineer using post-crack residual strength values. Service temperatures above approximately 90 °C to 100 °C may reduce mechanical properties. The fiber should not be relied upon for structural resistance under fire conditions because polypropylene melts and may generate additional pore pressure in dense concrete. No known adverse chemical reactions occur with Portland cement, supplementary cementitious materials, or common concrete admixtures, but compatibility with strong oxidizing chemicals in service should be evaluated on a case-specific basis.
| Comparative Parameter | SikaFiber Force PP-55/RAD55s | Micro Polypropylene Fiber | Steel Macro Fiber |
|---|---|---|---|
| Density | 0.91 g/cm³ | 0.91 g/cm³ | 7.85 g/cm³ |
| Typical length | 55 mm | 6 mm to 12 mm | 30 mm to 60 mm |
| Nominal diameter | 0.85 mm | 0.022 mm to 0.050 mm | 0.5 mm to 1.0 mm |
| Tensile strength | 600 MPa to 650 MPa | 300 MPa to 500 MPa | 1000 MPa to 2000 MPa |
| Elastic modulus | 9.5 GPa | 3.5 GPa to 8 GPa | 200 GPa |
| Corrosion behavior | Inert in alkaline concrete | Inert in alkaline concrete | Subject to corrosion unless galvanized or stainless |
| Typical dosage by mass | 3 kg/m³ to 9 kg/m³ | 0.6 kg/m³ to 1.5 kg/m³ | 20 kg/m³ to 60 kg/m³ |
| Primary concrete function | Post-crack structural reinforcement | Plastic shrinkage crack reduction | Post-crack structural reinforcement |
In precast operations, the fiber has been introduced into tunnel segment and underground vault mixes where steel reinforcement congestion complicated placement. The lower density of synthetic fibers allows hopper and skip loading without excessive increase in batch mass, and the absence of ferrous material eliminates magnetic interference in some automated handling systems. Published production data for precast segments indicate that demolding times are generally governed by matrix strength development rather than fiber type, but the fiber can affect slump retention under extended haul times when ambient temperatures exceed 30 °C. In such conditions, retempering with water is not recommended; additional superplasticizer should be used to restore workability within the limits defined by the concrete producer.