    • Product Name: SikaFiber Force PP-65/RAD65s - Macro Structural Synthetic Polypropylene Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 397566
    Product Name SikaFiber Force PP-65/RAD65s
    Material 100% virgin polypropylene
    Fiber Type Macro structural synthetic polypropylene fiber
    Fiber Shape Deformed macro monofilament
    Fiber Length 65 mm
    Fiber Diameter 0.9 mm
    Aspect Ratio 72
    Density 0.91 g/cm3
    Tensile Strength 600-650 MPa
    Elastic Modulus 9-10 GPa
    Melting Point 160-170 °C
    Alkali Resistance High
    Corrosion Resistance Non-corrosive
    Water Absorption Nil
    Dosage Range 2-9 kg/m3
    Packaging 5 kg bags
    Color Natural/white
    Compliance EN 14889-2 Class II; ASTM C1116 Type III
    Storage Dry conditions, protected from direct sunlight
    Shelf Life 5 years

    As an accredited SikaFiber Force PP-65/RAD65s - Macro Structural Synthetic Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Supplied in 1 kg water-soluble bags, 20 bags per 20 kg carton for direct concrete mixing.
    Container Loading (20′ FCL) Container Loading (20′ FCL): palletized SikaFiber Force PP-65/RAD65s macro structural synthetic polypropylene fiber bags, securely stowed and weight-compliant for transport.
    Shipping SikaFiber Force PP-65/RAD65s is a non-hazardous macro synthetic polypropylene fiber. It is not classified as dangerous goods for transport, with no UN number, hazard class, or packing group. It ships as general cargo in sealed, moisture-resistant bags or cartons on pallets, kept dry and protected from UV and damage.
    Storage Store SikaFiber Force PP-65/RAD65s in a cool, dry, well-ventilated area using original, unopened packaging. Keep pallets off the ground to prevent moisture damage. Protect from direct sunlight, excessive heat, open flames, ignition sources, and incompatible chemicals. Avoid dust generation, crushing, or bag tearing. Do not overstack. Use FIFO rotation and follow the manufacturer’s SDS and local regulations.
    Shelf Life Shelf life: 24 months from production date if stored unopened in original packaging, dry, cool, protected from moisture and sunlight.
    Application of SikaFiber Force PP-65/RAD65s - Macro Structural Synthetic Polypropylene Fiber
    In warehouses with very-narrow-aisle racking systems where racking post loads exceed 12 kN per leg and hard-wheeled forklift wheel loads reach 45 kN, SikaFiber Force PP-65/RAD65s is batched into ground-supported floor slabs as shrinkage and temperature reinforcement. The slab design is assessed against Concrete Society TR34, fourth edition, for panel deflection and load transfer. Fibre addition rates are set between 4.0 kg/m³ and 6.0 kg/m³. At 5.0 kg/m³, flexural performance is verified under ASTM C1609/C1609M-19 after first crack. Crushed granite or basalt aggregate with a nominal maximum size of 20 mm is used. Fibres are introduced at the ready-mix plant after coarse aggregate and before water to prevent hydrophobic polypropylene from coating aggregate surfaces. Mixing continues for 5–7 min at drum speed 12–18 rpm. Slump is adjusted to 120 ± 30 mm with a polycarboxylate ether superplasticiser. A laser screed is used for level control, followed by a twin-beam vibratory screed. Finish trowelling is stopped when the bleed-water sheen disappears. Over-trowelling is avoided because it can expose macro fibres at panel edges. The completed floor is cured with an ASTM C309 liquid membrane and saw-cut into panels no larger than 6 m × 6 m. Semi-rigid epoxy polyurea joint fillers are used to support hard-wheeled traffic.

    What distinguishes wet-mix shotcrete energy absorption when polyolefin macro fibres replace steel fibres?

    For initial tunnel support, SikaFiber Force PP-65/RAD65s is introduced into wet-mix shotcrete at dosage rates from 5.0 kg/m³ to 8.0 kg/m³ to meet energy absorption classes E500 to E1000 as defined in EN 14487-1:2022 and measured under EN 14488-5:2006. Aggregate size is capped at 8 mm. Slump before accelerator addition is controlled at 180–220 mm. A piston-type concrete pump with a delivery line diameter of at least 65 mm is used because the fibre length is 65 mm. Compressed air flow at the nozzle is set between 8 m³/min and 12 m³/min. Air pressure is held at 1.5–3.0 bar. Alkali-free accelerator is injected at the nozzle at 3–8% by mass of cement, depending on early strength targets. Layer thickness is limited to 50–100 mm per pass. Nozzle distance is maintained at 1.0–1.5 m with spraying square to the substrate. The fibres are mixed in the truck mixer for at least 5 min before accelerator addition. Rebound is monitored continuously at the spray bay. Trial panels are required before production because fibre balling occurs when the mixing time drops below 4 min or when aggregate moisture content exceeds 5%.Residual flexural performance is confirmed on square panel specimens under EN 14488-5. At 6.0 kg/m³, published industrial shotcrete data indicate energy absorption above 700 J for well-graded 8 mm aggregate mixes, but values shift with aggregate shape and accelerator compatibility. Published product-specific data for some accelerator families is limited. The terminal product is a dense sprayed concrete lining with fibre reinforcement distributed across the tunnel profile.Precast segment rings for mechanised tunnels are stripped, rotated, and stacked within 24 h. Edge chamfers and gasket seats are exposed to impact loads that cause spalling when plain concrete is used. SikaFiber Force PP-65/RAD65s is batched at 3.0–5.0 kg/m³ in segment concrete to improve crack control during handling and temporary loading. Tunnel segment serviceability is verified under EN 14651:2005+A1:2007 notched-beam tests for residual flexural strength. The fibre dosage is configured for post-crack resistance under temporary and secondary stresses. Main flexural capacity remains with conventional steel reinforcement unless a validated design according to fib Model Code 2010 is performed. Concrete w/c ratio is held between 0.32 and 0.38. Steam curing at 60°C for 6–8 h is followed by ambient storage. Polypropylene macro fibres do not soften at this curing temperature because the melting point is approximately 160°C. External mould vibrators are operated at low frequency to prevent fibre migration toward vertical surfaces. The finished segment is fitted with EPDM gaskets and bolted into ring assemblies.

    Hydraulic structures cast with 65 mm polypropylene macro fibres

    Erosion-resistant channel lining and stilling basin apron construction uses SikaFiber Force PP-65/RAD65s at 4.0 kg/m³ to 6.0 kg/m³. Concrete is specified under EN 206:2013+A1:2016 exposure class XF3 or equivalent. Flexural performance is checked under ASTM C1609/C1609M-19. In cast-in-place trapezoidal channels with wall thickness of 150 mm, the fibre dosage is set at the upper end of the range where cutoffs and grade changes concentrate hydraulic shear. Concrete is placed in lifts of 450 mm with a slump of 100 ± 20 mm. External form vibrators are mounted at 1.2 m intervals. The fibres are added before mixing water is introduced to avoid agglomerates. Pre-drying of fibres is not required unless packaging has been exposed to standing water. Curing with wet burlap is maintained for 7 days. The terminal product is a jointed or continuously reinforced drainage channel or apron with edge-spalling resistance provided by fibre bridging across surface microcracks.Bus rapid transit lane overlays placed by slipform paving equipment use SikaFiber Force PP-65/RAD65s as temperature-shrinkage reinforcement in thin concrete overlays. The dosage range is 3.0–5.0 kg/m³ when overlay thickness is between 80 mm and 120 mm over milled asphalt. Flexural performance is verified under ASTM C1609/C1609M-19. Fresh concrete is produced with a slump of 25–40 mm for slipform stability. Polycarboxylate superplasticiser is used to maintain workability without adding paste. Fibres are added to the aggregate stream before water to prevent floating during mixing. Transverse joints receive dowel baskets and tie bars before paving. Paving speed is kept between 1.2 m/min and 2.0 m/min. The surface is textured with a burlap drag perpendicular to the paving direction. Curing compound complying with ASTM C309 is applied immediately after texturing. The terminal product is a bus lane overlay with transverse saw-cut joints spaced at 3–4 m.

    When precast drainage culvert sections replace steel mesh with macro-synthetic fibre reinforcement

    Precast drainage culvert sections and utility pull boxes are batch-produced in fixed steel moulds. SikaFiber Force PP-65/RAD65s is added at 3.0 kg/m³ to 6.0 kg/m³ to control drying shrinkage, lifting, and backfill-induced cracking. The product is CE marked under EN 14889-2:2006 as a macro-synthetic fibre. Concrete mix design uses 10 mm nominal maximum aggregate to avoid fibre entanglement inside thin 100 mm walls. Mixing time after fibre addition is 4–6 min. Compaction is performed with high-frequency external mould vibrators. Fibre dosage above 6.0 kg/m³ is not used in thin 100 mm walls because placement and consolidation become difficult. Steam curing at 55–70°C accelerates stripping. Cylinder compressive strength is verified under EN 12390-3. The culvert section is demoulded only after reaching 70% of specified compressive strength. The terminal product is a precast culvert section or utility vault in which the fibre reinforcement handles secondary stresses without separate steel mesh placement.
    Free Quote

    Competitive SikaFiber Force PP-65/RAD65s - Macro Structural Synthetic Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    The product specified as SikaFiber Force PP-65/RAD65s is a macro-structural synthetic polypropylene fibre supplied in collated bundles for dry or automated dosing into concrete. The designation identifies a nominal fibre length of 65 mm and a macro-polymer geometry intended to contribute to post-crack residual strength after initial matrix cracking. The fibre is classified as a Class II macro-structural polymer fibre under EN 14889-2:2006 and as a Type III synthetic fibre under ASTM C1116/C1116M. The base polymer is virgin polypropylene with a published density of 0.91 g/cm³ when measured in accordance with ISO 1183-1:2019. The published equivalent fibre diameter is 0.80 mm, producing an aspect ratio of approximately 81. These dimensional parameters are the primary basis for mechanical anchorage rather than chemical bonding to the cementitious matrix.

    Because the fibre is non-hygroscopic, no product pre-drying is required before batching, but the water-soluble collated bundle packaging must be kept dry until addition. The fibre is chemically inert in the highly alkaline pH range of 12 to 13 typical of concrete pore solution and does not introduce chloride-bearing corrosion agents. Published manufacturer data lists tensile strength of approximately 500 N/mm² and tensile modulus in the range 3.5 GPa to 4.5 GPa under ISO 527-2. The polypropylene melt peak is reported at 160°C to 165°C by ISO 3146. Water absorption is less than 0.1% by mass. Published data for the exact RAD65s suffix configuration is limited; the geometric and mechanical values stated here reflect the base PP-65 fibre family and should be verified against the current manufacturer’s Declaration of Performance.

    Product Specification and CE Conformance Data

    Table 1 summarises the core specification parameters for SikaFiber Force PP-65/RAD65s. For structural use under the Construction Products Regulation, the product is expected to carry a Declaration of Performance referencing EN 14889-2:2006; project specifications should verify the notified body certificate and declared values rather than relying on generic published tables.

    AttributePublished value / classificationBasis
    Fibre classClass II macro-structural polymer fibreEN 14889-2:2006
    ASTM fibre typeType III synthetic fibreASTM C1116/C1116M
    Nominal length65 mmManufacturer technical data
    Equivalent diameter0.80 mmManufacturer technical data
    Aspect ratio81Length/diameter calculation
    Density0.91 g/cm³ISO 1183-1:2019
    Tensile strength500 N/mm² published typicalISO 527-2
    Tensile modulus3.5 GPa to 4.5 GPaISO 527-2
    Melt peak160°C to 165°CISO 3146
    Water absorptionless than 0.1% by massPolyolefin immersion
    Dosage range3.0 kg/m³ to 9.0 kg/m³Manufacturer technical guidance

    In production-scale batching, the collated bundle format is intended to eliminate manual pre-dispersion. The bundles are typically introduced after aggregate charging or with the aggregate stream; addition directly into dry cement before water is not recommended because electrostatic and moisture films can promote balling. In twin-shaft batch mixers with rotating blades maintained within manufacturer wear limits, fibre dispersion is generally complete within the normal mixing cycle. Field observations associated with worn scraper blades and dead zones in pan mixers indicate an increased risk of local clumping at dosages above 6.0 kg/m³; mixer condition should be verified before production. A measurable slump reduction occurs above 3.0 kg/m³. Correction is typically achieved with a high-range water-reducing admixture complying with ASTM C494/C494M Type F, and slump should be checked under EN 12350-2. Air content should be monitored after fibre addition because fibres can alter the spacing factor of the entrained air void system measured under ASTM C457/C457M. No pre-drying is required at ambient relative humidity, but prolonged exposure of opened packaging to moisture can compromise the water-soluble bundling film.

    How Does the 65-mm Anchor Geometry Influence Residual Flexural Capacity?

    The macro-synthetic fibre is not specified by tensile strength alone; post-crack performance is governed by fibre length, equivalent diameter, aspect ratio, surface morphology, and fibre count. The 65 mm nominal length provides embedment depth that must exceed the critical anchorage length for pull-out resistance. With an equivalent diameter of 0.80 mm, the aspect ratio of 81 places the product in the range where pull-out work contributes to toughness without excessive workability loss. At a dosage of 4.0 kg/m³, calculated fibre count based on published geometry is approximately 130,000 fibres/m³; a hooked-end steel fibre of 60 mm length and 0.90 mm diameter at the same mass dosage yields roughly 13,000 fibres/m³. The higher count influences crack spacing but does not equal the stiffness of steel.

    Residual flexural performance should be established by notched beam testing under EN 14651:2005+A1:2007 or ASTM C1609/C1609M. The EN method reports residual flexural tensile strength values at crack mouth opening displacement of 0.5 mm (fR1) and 2.5 mm (fR3); these values determine the fibre contribution in design models. Because the tensile modulus of polypropylene is between 3.5 GPa and 4.5 GPa, compared with 210 GPa for steel, the immediate post-crack load capacity at small crack openings is lower than a steel fibre of similar geometry. At larger crack openings, macro-synthetic fibres may exhibit pull-out rather than tensile rupture, and the load-deflection response becomes dependent on matrix strength and fibre surface treatment. Published data for this specific configuration is limited; project-specific beam tests are required for substitution calculations.

    Placement of concrete containing the macro-synthetic fibre is generally through conventional pumping and vibrating equipment. Pump lines of 100 mm nominal diameter or larger are common in slab and tunnel applications; smaller line diameters should be trialled because the 65 mm fibre length creates a length-to-line-diameter ratio that may promote blockages in tight bends. For machine-finished industrial slabs, the fibre may reduce bleed water and shorten the trowelling window; power trowel timing and blade angle should be adjusted in trial panels. Aggregate nominal maximum size of 20 mm to 25 mm is typical for dispersion; gap-graded mixes containing aggregate larger than 32 mm require additional verification. In wet-mix sprayed concrete, the fibre is added during batching and pumped through nozzle sizes of at least 50 mm; nozzle blockage risk increases at dosages above 7.0 kg/m³ unless pump capacity and hose diameter are suitable. Published guidance for this specific RAD65s configuration is limited, so field trials with the actual mixer and pump are required before production placement.

    When Steel Fibre Replacement Demands Revised Joint Layout and Corrosion Resistance

    The decision to replace steel fibres with the macro-synthetic polypropylene fibre is not a mass-equivalence substitution. Because density and modulus differ, engineering comparison should use residual strength class from beam tests, not fibre weight. In corrosion-sensitive environments such as marine splash zones, parking garage decks, and external pavements, the polypropylene fibre removes the risk of surface rust staining and chloride-induced fibre corrosion at exposed surfaces. The concrete cover to conventional reinforcing steel is still governed by EN 1992-1-1 or ACI 318 and must not be reduced solely because synthetic fibre is present. In ground-supported slabs, the fibre may permit wider joint spacing if the calculated residual flexural strength supports the design; joint elimination is not automatic and requires a structural model such as the Concrete Society Technical Report 34 or equivalent.

    Table 2 compares the macro-synthetic fibre with a typical hooked-end steel fibre and a micro-synthetic polypropylene fibre.

    ParameterSikaFiber Force PP-65/RAD65sHooked-end steel fibreMicro-synthetic PP fibre
    Nominal length65 mm60 mm typical6–12 mm
    Equivalent diameter0.80 mm0.90 mm typical0.018–0.038 mm
    Density0.91 g/cm³7.85 g/cm³0.91 g/cm³
    Tensile modulus3.5–4.5 GPa210 GPa3.5 GPa typical
    Typical dosage3.0–9.0 kg/m³20–40 kg/m³0.6–1.8 kg/m³
    Primary functionPost-crack control in slabs, shotcretePost-crack residual strengthPlastic shrinkage control
    Corrosion at exposed surfacesNonePossible staining/spallingNone

    The lower tensile modulus of polypropylene relative to steel has direct consequences for long-term cracked serviceability. Polypropylene exhibits viscoelastic creep under sustained load; cracked fibre-reinforced concrete may show additional deflection over time. Published long-term creep data for this specific macro-synthetic fibre is limited, and design should not extrapolate short-term beam results without verification. The fibre is not a direct substitute for primary flexural reinforcement in beams, columns, or suspended slabs unless the design explicitly uses fibre-reinforced concrete constitutive models and the residual strength class has been determined by testing. In fire-exposed concrete, the polypropylene melts at approximately 160°C, which may create pore-pressure relief channels but simultaneously removes the post-crack reinforcement; residual capacity after fire must be assessed separately. The product should be stored below 40°C in dry conditions and kept away from prolonged direct sunlight to preserve packaging integrity. Chemical exposure to strong oxidising media or organic solvents should be evaluated by immersion testing before use. At dosages above 6.0 kg/m³, workability loss and fibre balling risk increase; mix adjustments and mixer maintenance become critical. No retardation or acceleration of cement hydration is documented. Air-entraining admixture dosage should be verified because the fibre surface can modify air void spacing. These operational boundaries define the appropriate use envelope for the fibre in structural concrete applications.