| HS Code | 781344 |
| Productname | Adfil Ignis |
| Producttype | Synthetic Micro Fire Protection Fibers |
| Material | 100% virgin polypropylene |
| Fiberlength | 6 mm |
| Fiberdiameter | 18 microns |
| Aspectratio | 333 |
| Density | 0.91 g/cm3 |
| Meltingpoint | 160 deg C |
| Ignitionpoint | >360 deg C |
| Dosage | 1.0-2.0 kg/m3 |
| Alkaliresistance | Excellent |
| Acidresistance | Excellent |
| Saltresistance | Excellent |
| Waterabsorption | Nil |
| Thermalconductivity | Low |
| Electricalconductivity | Low |
| Colour | White |
| Packaging | 1 kg water-soluble bags |
| Fibercount | Approximately 700 million fibers per kg |
| Storage | Dry, protected from direct sunlight |
As an accredited Adfil Ignis - Synthetic Micro Fire Protection Fibers factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Adfil Ignis synthetic micro fire protection fibers are supplied in 20 kg moisture-resistant sacks, palletized and shrink-wrapped for safe transport. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with Adfil Ignis - Synthetic Micro Fire Protection Fibers, palletized, shrink-wrapped, and secured for ocean transport. |
| Shipping | Adfil Ignis Synthetic Micro Fire Protection Fibers are typically shipped in sealed, moisture-resistant bags or drums, palletized and shrink-wrapped. Transport in dry conditions, avoiding punctures, moisture and excessive heat. Normally classified as non-hazardous; always follow the supplier’s SDS, packaging instructions and local transport regulations. |
| Storage | Store Adfil Ignis – Synthetic Micro Fire Protection Fibers in original, sealed packaging in a cool, dry, well-ventilated area. Protect from moisture, direct sunlight, heat, and ignition sources. Keep separate from acids, alkalis, oxidizers, and incompatible materials. Prevent dust generation; use suitable PPE. Maintain clean, labelled containment, avoid pallet damage, and follow the supplier’s SDS. |
| Shelf Life | Shelf life is approximately 24 months when stored cool, dry, sealed, and away from direct sunlight in original packaging. |
In high-solids epoxy intumescent formulations intended for structural steel fire protection, the synthetic micro fibre is incorporated at 0.5–2.0 wt% of total batch weight to create a discontinuous fibrous network within the ammonium polyphosphate/pentaerythritol/melamine char-forming matrix. During the melt viscosity collapse that precedes carbonific expansion, the fibre network retains developed char on the steel substrate and reduces linear crack propagation along the edges of the expanded layer. Formulations for on-site spraying are typically qualified under ASTM E119, UL 263, ISO 834-1, and EN 13381-8. Production-scale mixing is carried out in a high-speed disperser with a saw-tooth impeller running at a tip speed of 8–14 m/s for 20–30 min; the fibre is introduced after the intumescent pigment grind and before final rheology adjustment. Addition above 2.5 wt% has been associated with elevated pressure in 0.021–0.025 inch airless spray tips and with a measurable rise in low-shear viscosity above 1,500 mPa·s at 25°C. At lower addition ranges, char defects observed after furnace exposure show a tendency toward interconnected surface cracks, although published crack-length data for this specific fibre are limited. Plural-component airless spray equipment with 45:1–68:1 pump ratios is used for field application, while brush-grade systems may be applied at a wet film thickness of 1.0–2.0 mm per coat. Terminal product types include thin-film epoxy intumescent coatings for structural steel, waterborne acrylic intumescent coatings for interior building columns, and hydrocarbon-rated high-build systems for process equipment.
Cementitious sprayed fire resistive material lines operate within a water-to-dry-mix ratio of 0.55–0.75 and a wet density of 900–1,200 kg/m³. Synthetic micro fibre is metered into the dry mix at 0.3–0.7 wt% of total batch weight, typically through a separate loss-in-weight feeder, because direct drum dumping can create agglomerates that blind 6–10 mm aggregate screens. The fibre modifies wet-state cohesion of the slurry and reduces segregation of vermiculite and perlite particles inside the pump hopper. Rotor-stator and piston pumps are both used, with pump outlet pressure generally 10–40 bar depending on hose length; fibre addition shifts the pressure response, but published line-specific pressure profiles for this product are limited. Application is carried out with a dry-mix gun and spray nozzle at atomising air pressure of 3–6 bar. The installed material is tested for bond strength, adhesion, and fire resistance according to ASTM E736, ASTM E759, ASTM E760, EN 13381-4, and UL 263. Drying shrinkage and substrate deflection resistance are monitored because excessive fibre loss through pneumatic conveying can lower wet-state yield stress and produce slumping on vertical steel members. Terminal product types include sprayed fireproofing for steel floor decks, beams, columns, and fire-rated duct enclosures.
| Standard designation | Test focus | Relevance to synthetic micro fibre addition |
|---|---|---|
| ASTM E736 | Cohesion/adhesion bond resistance of sprayed fire-resistive material | Evaluates delamination resistance at the concrete or steel interface |
| ASTM E759 | Effect of structural deflection on applied fire-resistive material | Indicates deformation tolerance of the fibre-reinforced wet-applied layer |
| ASTM E760 | Bond strength of sprayed fire-resistive material to steel | Provides a direct pull-off test across the coating/substrate junction |
| EN 13381-4 | Contribution of sprayed passive fire protection to structural steel members | Links installed thickness to fire resistance classification |
| UL 263 | Fire tests of building construction and materials | Establishes time-temperature exposure acceptance for the protected assembly |
Halogen-free flame retardant cable sheathing compounds based on EVA/LLDPE matrices with 55–65 wt% ATH/MDH filler loading are compounded on co-rotating twin-screw extruders with 40:1 L/D ratio and melt temperatures not exceeding 190°C. Synthetic micro fire protection fibre is added at 2–8 phr to improve char cohesiveness during vertical flame propagation and to reduce flaming droplet formation from the sheath. The fibre is introduced through a side feeder downstream of the mineral filler atmospheric vent, after ATH/MDH dispersion is complete, to limit fibre attrition in the high-shear melting zone. Cable compounds produced with this fibre must satisfy IEC 60332-3-24, IEC 60754-1, IEC 61034-2, EN 50399, and the Euroclass Cca-s1,d1,a1 classification requirements. Melt processing above 200°C has been linked to screen pack plugging, surface roughness, and inconsistent char integrity; barrel temperature profiles are therefore set with a reverse thermal gradient at the die, with the die zone held 10–15°C below the high-shear zone. Terminal product types include low-smoke zero-halogen sheathing for building control cable, transit rail power cable jackets, and industrial instrumentation cable.
Continuous gypsum board lines convey rehydrating slurry from pin mixer discharge to knife cutting within 20–30 min, with forming belt speeds of 30–70 m/min. Synthetic micro fibre is metered into the dry stucco stream at 0.5–1.5 wt% and must survive the pin mixer, which imparts high mechanical energy for only 2–4 s before slurry is distributed onto the paper face liner. The fibre improves shrinkage crack resistance during the multi-deck drying stage at 150–180°C, where uneven moisture removal can otherwise produce core fissures in 12.7 mm and 15.9 mm board. Fire-rated board qualification is conducted under ASTM C1396/C1396M, ASTM E119, EN 520, and EN 15283-1. A processing boundary occurs at high relative humidity; when the raw fibre is stored above 60% RH, pre-drying at 50–60°C for 2–4 h is recommended to prevent fibre bundles from forming low-density lumps in the stucco feed. Terminal product types include Type X fire-resistant plasterboard, shaftliner for elevator and stair enclosures, and exterior sheathing with increased angular shrinkage resistance.
For rigid phenolic foam insulation, the liquid resin rheology before cure is characterised by low elongational viscosity, and synthetic micro fibre addition at 0.2–1.0 wt% is used to reinforce uncured cell walls before crosslinking. The acid-catalysed resole resin has a pH of 2.5–3.5 and a blowing agent blend of methylene chloride and hydrocarbons. The fibre is dispersed into the resin side before the head mixer; mixing head pressure is generally maintained at 8–12 bar, with cure ovens set at 55–80°C for 10–20 min. Fire performance is classified under EN 13501-1, with typical target classes of B-s1,d0, and surface flame spread is evaluated under ASTM E84 or NFPA 255. The processing boundary for this application is acid and moisture tolerance; fibre with moisture content above 0.1 wt% can interfere with the phenolic cure exotherm and reduce closed-cell content. Terminal product types include rigid phenolic foam insulation boards for HVAC ductwork, soffit insulation panels, and insulated core laminates for fire-rated doors.
One-part neutral-cure silicone firestop sealant formulations are compounded under vacuum at 10–20 mbar absolute in a double planetary mixer fitted with a high-speed disperser. Synthetic micro fibre is added at 3–7 phr to the base polymer before calcium carbonate and zinc borate fillers are introduced. The fibre modifies low-shear viscosity and reduces sag in large-penetration configurations, with typical slump after 24 h at 50°C held below 3 mm. Fire resistance is qualified under ASTM E814, UL 1479, EN 1366-3, and ISO 10295-1. Mixing is carried out at planetary speeds of 25–40 rpm and high-speed disperser speeds of 1,500–2,000 rpm; fibre wetting is confirmed by absence of visible undispersed bundles before the vacuum phase. Terminal product types include firestop sealant cartridges for metallic and non-metallic penetrations, self-leveling floor sealants for pipe and cable openings, and gun-grade gap sealants for linear joints.
Competitive Adfil Ignis - Synthetic Micro Fire Protection Fibers prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Adfil Ignis – Synthetic Micro Fire Protection Fibers are monofilament polypropylene microfibers formulated for addition to dense, low-permeability cementitious matrices. The product is intended for high-strength concrete, precast tunnel segments, columns, and sprayed concrete where fire resistance depends on limiting moisture-driven explosive spalling. Under heating, the fibers soften and melt, leaving continuous pressure-relief channels through which water vapour can escape before pore pressure exceeds the tensile capacity of the hot concrete. Published product-specific numerical data for Adfil Ignis is limited; the dimensional and performance ranges stated below are therefore representative of EN 14889-2:2006 compliant synthetic micro polypropylene fire-protection fibers and should be confirmed against the manufacturer’s batch-specific technical data sheet and CE certificate for any project.
The explosive spalling mechanism becomes acute in concretes with compressive strength above 60 MPa and water/cement ratio below 0.35, particularly when silica fume or high-range water reducers produce a matrix so dense that vapour migration is restricted. During rapid heating, free water and chemically released water generate pore pressure faster than mass transport can relieve it. Because hot concrete has reduced tensile strength near the exposed surface, the pressure gradient can produce sudden spalling of concrete fragments. Adfil Ignis does not suppress the temperature rise itself; it introduces a controlled discontinuity network that activates at the polymer melt range and links pores, thereby reducing peak internal pore pressure.
As the surface temperature rises above 100 °C, free water begins to vapourise and migrates inward, condensing in cooler zones. This moisture front creates a saturated layer with low permeability that blocks vapour escape. The resulting pore pressure can exceed 2 MPa to 4 MPa in dense concretes, while the hot tensile strength remains below 1 MPa near the exposed face. Synthetic microfibers provide a heat-triggered pressure relief mechanism. The polypropylene monofilaments soften between 150 °C and 170 °C, then decompose into capillary-size channels with diameters close to the original fiber diameter. These channels reduce the effective vapour path length and allow pressure equalisation before crack propagation becomes unstable.
Dispersed fiber count is more important than total fiber mass in this mechanism. A finer monofilament yields a higher number of discrete channels per cubic metre for a given dosage. Consequently, spalling resistance depends strongly on uniform distribution through the cementitious matrix, wet-out behaviour, and the absence of fiber agglomeration during batching. The fibers do not act as primary post-crack reinforcement in the same way as steel or macro synthetic fibers; their function is thermal-pressure relief rather than structural crack bridging.
Without a header, the next application context is described directly. In tunnel segment production, the concrete mixture is typically batched in a high-shear twin-shaft compulsory mixer and discharged into carousel molds where compaction is supplied by external vibration. Fiber addition before the aggregate is fully wetted may result in visible clumps on the segment inner surface. The preferred sequence is to charge coarse and fine aggregates first, add the fibers with the initial mixing water, and then introduce cement, silica fume, and superplasticizer only after fiber bundles have opened into individual filaments.
Table 1 provides the representative specification profile for the synthetic micro fire-protection fiber class.
| Property | Representative range or declared value | Test method or basis |
|---|---|---|
| Fiber chemistry | Polypropylene monofilament | Manufacturer declaration |
| Nominal diameter | 18 µm – 32 µm | Optical microscopy, EN 14889-2:2006 |
| Nominal length | 6 mm – 12 mm | Manufacturer declaration |
| Density | 0.91 g/cm³ | ASTM D792 |
| Melt range | 155 °C – 170 °C | Differential scanning calorimetry, ISO 11357-3 |
| Water absorption | <0.1 % by mass | ASTM D570 |
| Alkali resistance | No significant degradation in cement pore solution at pH 12.5 | Immersion test, manufacturer data |
| Tensile strength | 300 MPa – 600 MPa | ISO 2062 |
| Compliance | EN 14889-2:2006; ASTM C1116/C1116M Type III synthetic fiber | CE marking, manufacturer certificate |
| Typical dosage | 1.0 kg/m³ – 3.0 kg/m³ | Project fire test program |
The operational boundary for dosage is not fixed by the fiber alone. Below 1.0 kg/m³, the melt-channel network may be too sparse in very dense concretes exposed to severe hydrocarbon or RWS curves. Above 3.0 kg/m³, workability reduction, pump pressure increase, and fiber balling can occur in low-paste mixtures. In production-scale ready-mix trucks, adding the fiber too quickly into a high-speed drum can create electrostatically bound clumps that survive transport and appear as surface defects after placing.
Polypropylene is hydrophobic and has low water uptake, which allows the fiber to remain dimensionally stable in wet concrete before the fire event. The material is not affected by the alkaline cement paste environment because the polymer backbone lacks hydrolytically sensitive ester linkages. However, storage must avoid temperatures above 50 °C, direct sunlight, and contact with solvents or strong oxidising agents that can degrade the monofilament or cause bundles to fuse. In central mixing plants, the fiber should be introduced through a fiber dispenser or pre-dosed water-soluble bag rather than pneumatically blown into dry aggregate without dust control.
In high-performance concrete, rheology is sensitive to the sequence of admixture addition. When Adfil Ignis is added together with a polycarboxylate ether superplasticizer before the aggregate is uniformly moist, the water-reducing polymer can coat the hydrophobic fiber surface and delay dispersion. The resulting batch-to-batch variance is observed as irregular surface voids or increased mixing time. A more stable sequence is to add fibers after 50 % of the batch water has been incorporated and to maintain wet mixing for at least 90 seconds after filament separation.
For tunnel segments with specified residual moisture below 3 % by mass, conditioning of samples at 60 % relative humidity before fire testing is necessary because pore pressure generation is controlled by free moisture content. Specimens dried too aggressively may show unrealistically low spalling damage, while saturated specimens may fail even with fiber addition if the concrete permeability is extremely low.
In traffic tunnels, the design fire often follows the Rijkswaterstaat RWS curve, which reaches 1200 °C within 5 min and 1350 °C at 120 min. Under such rapid heating, the temperature gradient across a segment lining can exceed 400 °C/mm at the exposed face, producing severe thermal dilatation and moisture pressurisation. For these exposures, fiber dosage should be validated by full-scale or intermediate-scale fire tests on the actual mix design rather than by thermal analysis of the fiber alone.
Published data for Adfil Ignis in specific RWS-tested segment configurations is limited, and the controlling performance data are generated by project-specific tests such as slab furnace exposure under ISO 834-1:1999 or a hydrocarbon curve. In such tests, observed spalling depth, mass loss, and residual cross-section are compared against acceptance criteria defined by the tunnel owner. The fiber contributes one control parameter; it does not replace thermal barrier linings, passive reinforcement, or concrete cover requirements.
In high-rise columns and shear walls, the standard fire curve of ISO 834-1:1999 may be used for verification. Dense high-strength columns containing silica fume can experience spalling after 15 min to 30 min of exposure if macrosteel fibers or micro polypropylene fibers are absent. Adfil Ignis is added to the concrete mix to increase the probability that the element retains its cross-section long enough for the reinforcing steel to remain below the critical temperature. The fiber does not reduce thermal conductivity of the concrete and does not act as an intumescent coating.
For sprayed concrete, fiber addition must account for the different mixing and placement route. Dry-mix shotcrete introduces the fiber into the dry material stream before the nozzle, while wet-mix shotcrete introduces the fiber in the batching plant. In both cases, the fiber should be dispersed before the accelerator is added. If an alkali-free accelerator is injected at the nozzle, the fiber is already embedded in the paste and does not require additional wetting time. Published data on the exact fiber recovery rate in rebound for Adfil Ignis is limited; rebound sampling should be part of preconstruction spray trials.
Table 2 compares the synthetic micro fire-protection fiber class with steel and macro synthetic fibers to illustrate the product differentiation.
| Characteristic | Adfil Ignis synthetic micro class | Steel fiber | Macro synthetic fiber |
|---|---|---|---|
| Density | 0.91 g/cm³ | 7.85 g/cm³ | 0.90 g/cm³ – 0.95 g/cm³ |
| Diameter | 18 µm – 32 µm | 500 µm – 1000 µm | 300 µm – 1000 µm |
| Primary function in fire | Melt-channel pressure relief | Mechanical crack bridging at low strain | Post-crack toughness and shrinkage control |
| Corrosion risk | None | Possible if exposed at surface cracks | None |
| Typical dosage | 1.0 kg/m³ – 3.0 kg/m³ | 20 kg/m³ – 60 kg/m³ | 3.0 kg/m³ – 9.0 kg/m³ |
| Post-crack structural contribution | Negligible | High | Moderate |
| Pumping impact at typical dosage | Low | High at upper dosage | Moderate |
Compared with conventional shrinkage-control polypropylene microfibers, the fire-protection grade is distinguished by finer filament diameter and higher filament count per kilogram at the specified dosage. This distinction matters because spalling resistance is governed by the spacing of melt channels, not solely by fiber mass. A poorly dispersed coarse macrofiber cannot provide the same vapour-relief density at 1.0 kg/m³ to 3.0 kg/m³. Conversely, Adfil Ignis is not a replacement for structural steel fibers where post-crack flexural toughness is required under EN 14889-1 or EN 14889-2:2006 Class II macrofiber provisions.
In precast plants, the most common production bottleneck is not mixing but fiber transfer into the mixer. Bulk bag discharge without a controlled screw feeder can deliver irregular fiber mass and produce dosage variation between batches. Automated dosing units with mass loss correction have reduced batch-to-batch variation to below 2 % of target fiber mass in some installations, but published performance data for Adfil Ignis-specific dispensing systems is limited. When dosing is accurate but mixing is shortened below the filament separation time, the unopened bundles remain visible at the form face after demolding.
The fiber is compatible with typical concrete admixtures including polycarboxylate ether, naphthalene-based superplasticizers, and air-entraining admixtures. Freeze-thaw resistance still requires a separate air-void system according to ASTM C260 or EN 934-2; the fiber does not substitute for entrained air. The product should not be used as the sole means of fire protection where the concrete cover is below code requirements or where the element is expected to carry load during fire without supplemental thermal insulation.
For moisture-saturated structures with very low permeability, the fiber reduces but does not eliminate spalling risk. If the matrix has a water/cement ratio below 0.30 and contains more than 10 % silica fume by mass of cement, the vapor pressure may still generate localized spalling even with fiber addition if the heating rate is severe. In such cases, the design should include increased cover, thermal barriers, or higher fiber dosage validated by fire testing.