Liwei Group Co., Ltd

Products

Adfil Sinta 12 mm (SINTA 12 mm) - Monofilament Polypropylene Fiber

    • Product Name: Adfil Sinta 12 mm (SINTA 12 mm) - Monofilament Polypropylene Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 758022
    Material 100% virgin polypropylene
    Fiber Type Monofilament
    Length 12 mm
    Diameter 0.018 mm
    Aspect Ratio 667
    Density 0.91 g/cm³
    Tensile Strength 400 MPa
    Elastic Modulus 3500 MPa
    Melting Point 165 °C
    Autoignition Temperature >400 °C
    Alkali Resistance Excellent
    Acid Resistance Excellent
    Water Absorption Nil
    Thermal Conductivity Low
    Electrical Conductivity Low
    Dosage 0.6-1.8 kg/m³
    Packaging 0.6 kg bags
    Color Natural

    As an accredited Adfil Sinta 12 mm (SINTA 12 mm) - Monofilament Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Supplied in 600 g water-soluble bags, 20 bags per carton, totaling 12 kg net weight.
    Container Loading (20′ FCL) Container Loading (20′ FCL): Palletized Adfil Sinta 12 mm monofilament polypropylene fiber, securely stowed, shrink-wrapped, and braced for safe ocean transport.
    Shipping Adfil Sinta 12 mm (SINTA 12 mm) monofilament polypropylene fiber ships as non-hazardous, non-regulated general cargo. It is packed in moisture-resistant bags or sacks, palletized and shrink-wrapped. Keep dry, away from UV and ignition sources. Handle with normal PPE; avoid dust generation and packaging damage.
    Storage Store in a dry, cool, well-ventilated area away from direct sunlight, moisture, heat, ignition sources, and strong oxidizers. Keep in original sealed packaging on pallets, off the ground, to prevent contamination and UV degradation. Avoid prolonged sunlight and excessive temperature fluctuations. Store separately from incompatible chemicals. Do not stack excessively. Follow local regulations and manufacturer’s shelf-life recommendations. Maintain good housekeeping.
    Shelf Life Shelf life is 24 months from date of manufacture when stored unopened, dry, at moderate temperature, away from direct sunlight.
    Application of Adfil Sinta 12 mm (SINTA 12 mm) - Monofilament Polypropylene Fiber

    When a 0.45 w/c slab is cast at evaporation rates above 0.5 kg/m²/h

    In industrial floor slabs and external hardstandings, early-age plastic shrinkage cracking is governed by surface evaporation rather than 28-day strength. Adfil Sinta 12 mm monofilament polypropylene fibre is introduced at 0.6–0.9 kg/m³ in ready-mix concrete supplied under EN 14889-2:2006 conformity and evaluated according to ASTM C1579-21 to quantify crack reduction against plain reference concrete. In the batching sequence, the fibre is added after the coarse aggregate fraction has been charged and before the full water volume enters the twin-shaft compulsory mixer, because mechanical dispersion arises from aggregate interstitial movement rather than paddle shear alone. At dosages above 1.8 kg/m³, the yield stress of the concrete increases sufficiently that the water demand must be re-adjusted with a high-range water reducer; without that adjustment, the producing plant commonly records a slump reduction of 25–35 mm and longer discharge intervals from 2.0 m³ truck-mixer drums. The fibre is compatible with concrete pumped through 100 mm minimum inner-diameter pipeline when full wetting has occurred before pump start. The terminal products include laser-screeded industrial floor slabs, warehousing slabs on grade, external hardstandings, and agricultural apron slabs. Under ACI 302.1R-15 floor construction tolerances, the placement window between initial screeding and final trowel pass remains the critical control period; the fibre does not replace curing membranes or polyethylene sheeting where evaporation control is required by ACI 308R-16. The operational boundary is that the fibre is not a substitute for structural reinforcement or crack-width steel in conventionally reinforced slabs, and it is not applied to slabs over 300 mm thick in place of structural steel without project-specific testing.

    Test method / standardRequirement under industrial floor slab useVerification boundary
    EN 14889-2:2006Polymer fibre geometry and alkali resistance in concreteManufacturer-declared diameter class and 12 mm length tolerance
    ASTM C1116/C1116M-23Fibre-reinforced concrete specificationBatch documentation of fibre type and addition rate in kg/m³
    ASTM C1579-21Plastic shrinkage cracking under restrained dryingComparative crack area reduction measured against plain concrete after 6 h

    Before pigment paste is added to a wet-cast architectural panel mix, the 12 mm monofilament is dispersed in the moving granular bed of a counter-current mixer operating at low rotational speed. In this wet-cast precast application, the fibre dosage is 0.8–1.2 kg/m³, and the concrete is supplied under EN 13369:2023 common rules for precast concrete products, with the fibre itself evaluated against EN 14889-2:2006. The production process passes through a counter-current mixer, steel moulds with external table vibration at 50–60 Hz, and demoulding after the concrete reaches a stripping strength of at least 12 MPa; the presence of the 12 mm fibre reduces edge breakout at demoulding, but only when the vibration time is not extended beyond the compaction limit of the mix. For acid-etched or polished surfaces, the dosage is held below 1.0 kg/m³ because fibre ends exposed at the face can alter the final light reflectance. Terminal products are architectural facade panels, window surrounds, solid balustrade panels, and precast coping units. The limitation is that the fibre does not reduce flexural cracking after hardened concrete is loaded; any claim for tensile performance must be supported by ASTM C1609/C1609M-19 residual strength testing, and published data for this specific aesthetic configuration is limited.

    Under which thermal exposure does 12 mm monofilament alter spalling pressure in tunnel linings?

    In wet-mix sprayed concrete for primary tunnel linings, polypropylene monofilament is not a structural reinforcing fibre; its function is twofold: reducing early-age plastic shrinkage cracking before the binder sets and creating percolation pathways after melting at 160–170°C under fire exposure. The dosage applied for early-age shrinkage control in tunnel lining shotcrete is 0.9–1.5 kg/m³, while spalling resistance in high-strength sprayed concrete may require 1.5–2.0 kg/m³ as a starting point, followed by fire testing under ISO 834-1:1999 to determine actual spalled depth. In the wet-mix process, the fibre is added during batching into the concrete plant mixer before the material is transported in a concrete truck mixer and discharged into a hydraulic S-valve concrete pump; compressed air at the nozzle at 7–10 m³/min and an accelerator deliver the mix through a 50 mm nozzle onto the excavation profile. The relevant specifications include EFNARC 1996 for sprayed concrete and EN 14889-2:2006 for the polymer fibre conformity. Field records show that fibre clumping at the nozzle is rare at this length provided the fibre is not injected separately at the nozzle; separate nozzle injection generally favours longer steel fibres and creates irregular distribution for 12 mm monofilament. The terminal products are primary tunnel linings, rock support shells, slope stabilisation layers, and underground repair overlays. The explicit boundary is that the fibre cannot be used to satisfy post-crack residual flexural strength requirements under ASTM C1609/C1609M-19; if residual strength is required, macro-synthetic or steel fibres must be combined with or substituted for this micro monofilament.

    In calcium sulfoaluminate-based self-leveling underlayment plants, the 12 mm monofilament is handled as a dry-mix component rather than a concrete admixture. The fibre is added to the ribbon blender after the binder and before the cellulose ether is introduced, which minimises electrostatic clumping on the blender walls; the dosage is 0.5–0.8 kg/m³ of wet screed, and exceeding 1.0 kg/m³ reduces the flow-spread diameter measured according to EN 12706 below the 250 mm commonly specified for self-leveling underlayments. The dry-mix process runs in a twin-ribbon blender for a total mixing time of 120–180 s at low moisture, with the fibre added through a volumetric screw feeder to control batch-to-batch fibre content. On site, the product is mixed with a low-speed paddle mixer, pumped through a worm pump, poured over primed substrates, and de-aerated with a spike roller before curing. The terminal products are self-leveling floor underlayments, industrial screeds, acoustic levelling layers, and repair screeds for concrete and screed substrates. Compliance is aligned with EN 13813:2002, and the fibre is evaluated under EN 14889-2:2006; for calcium sulfoaluminate binders with rapid setting behaviour, the polypropylene fibre remains chemically inert, but no acceptance is claimed without trial mixing because rapid-setting formulations can generate an early surface skin that traps fibre near the top.

    Zero-slump pipe machine feeding and the 12 mm dispersion threshold under vertical vibration

    For dry-cast concrete pipe and culvert manufacture, the 12 mm monofilament is introduced at 0.6–0.9 kg/m³, with the upper limit set by the compaction window of zero-slump concrete. The production line uses a planetary or twin-shaft compulsory mixer, a ribbon screw feed to the packerhead or vertical vibration station, and direct vibration at amplitudes between 0.2–0.5 mm; fibre addition follows the dry aggregate fraction and is mixed for 30–60 s before the casting water enters. If the dosage exceeds 0.9 kg/m³, the fibre disrupts particle packing and increases rejection rates at the pipe spigot edge, and machine-specific validation is required before production batches are released under EN 1916:2002 or ASTM C76-22. The terminal products are reinforced and unreinforced concrete pipes, box culverts, manhole rings, and drainage units. The fibre contributes to green strength during demoulding and reduces edge damage in bell-and-spigot joints, but it is not a recognised replacement for the steel reinforcement prescribed in ASTM C497-20 structural acceptance testing. Published data specific to the interaction of monofilament length distribution and packerhead roller compaction is limited; therefore production trials with the exact machine model are the only accepted validation method.

    At the dry-mix blender for ETICS basecoat mortar production, short 12 mm monofilament is blended with graded silica sand, cellulose ether, redispersible polymer powder, and Portland cement before bagging. The fibre dosage in the basecoat wet mortar is 0.4–0.8 kg/m³; above 1.0 kg/m³, the mortar can exhibit increased trowel drag and visible fibre protrusion through 1.5 mm embedded glass-fibre mesh. The blender runs in a low-speed ribbon mixer with a total cycle time of 180–240 s; the fibre is added in the final 90 s to prevent lodging in the spray nozzles of automated packaging screw conveyors. On the thermal insulation composite system site, the powder is mixed with water using a low-speed paddle mixer, applied as adhesive and basecoat over mineral wool or EPS boards, with glass-fibre mesh embedded in the fresh basecoat at a minimum cover of 1.5 mm. The finished render is covered by EN 998-1:2016 and EAD 040083-00-0404 for ETICS with rendering. The terminal products are basecoat render, glass-fibre mesh embedding bedding, repair mortar, and protective render over insulation boards. The fibre is not suitable for exterior surfaces where it will be exposed to prolonged ultraviolet radiation after topping film erosion; it must remain embedded below the polymer-modified render film or be painted over.

    Free Quote

    Competitive Adfil Sinta 12 mm (SINTA 12 mm) - Monofilament Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Adfil Sinta 12 mm (SINTA 12 mm) is supplied as a monofilament polypropylene fiber for direct addition to concrete, mortar, and wet-mix shotcrete. The nominal cut length is 12 mm, and the product is produced by melt extrusion into a closed circular cross-section rather than by fibrillation of a slit film. This geometry controls the fiber’s behavior in a cementitious matrix: the smooth monofilament surface reduces water demand compared with high-specific-surface fibrillated fibers, but it also reduces mechanical anchorage relative to twisted or net-shaped macrofibers. Because the fiber is hydrocarbon-based and non-corroding, it does not introduce the chloride-induced electrochemical activity associated with steel reinforcement. Specification for synthetic fiber-reinforced concrete is typically assessed under ASTM C1116/C1116M, and in European markets under EN 14889-2:2006 for polymer fibres used in concrete.

    Published data for this specific configuration is limited; batch-specific values for diameter, tensile strength, and elastic modulus should be drawn from the manufacturer’s technical data sheet or Declaration of Performance. The following table records representative property bands for extruded polypropylene monofilament fibers in the 12 mm class, not a substitute for certified batch averages.

    Representative property band for 12 mm monofilament polypropylene fibers
    PropertyTypical bandTest reference
    Monofilament length12 mmManufacturer cut-length inspection
    Cross-section diameter0.20–0.30 mmOptical microscopy / manufacturer batch certificate
    Specific gravity0.91 g/cm³ISO 1183-1:2019
    Tensile strength300–450 MPaASTM C1557-20
    Elastic modulus3.5–4.2 GPaASTM C1557-20
    Elongation at break15–30%ASTM C1557-20
    Melt temperature160–170°CISO 11357-3:2018
    Water absorption<0.1% by massISO 62:2008

    How does a 12 mm monofilament control plastic shrinkage cracks at low addition rates?

    For a 12 mm fiber to affect early-age cracking, the fiber volume fraction must be sufficient to intercept bleeding-water channels and increase the tensile strain capacity of the plastic concrete surface. In restrained slab placements, plastic shrinkage cracking is evaluated by ASTM C1579-21; comparable monofilament polypropylene fibers at dosages of 0.6–1.8 kg/m³ typically reduce crack area and maximum crack width relative to plain concrete. The crack-reducing mechanism is not structural load transfer but the formation of a uniform network of fine flexible filaments that bridge the water-air interface and redistribute capillary tensile stress during the first 6–12 h after placement.

    The lower specific surface area of a circular monofilament allows the fiber to disperse without the high water demand observed with fibrillated microfibers. In low-water mixes, a fibrillated fiber may reduce slump by 20–40 mm at equal volume, while a monofilament can limit slump loss to 10–25 mm depending on aggregate grading and admixture chemistry. No reliable independent dataset exists for the exact SINTA 12 mm slump response; site trial mixes with the actual cement, superplasticizer, and aggregate are required before production batching.

    On truck-mixer lines with 7–9 m³ loads, the fiber is added either to the aggregate weigh hopper or into the mixer after approximately 80% of mixing water has been introduced. Addition after the superplasticizer has dispersed can produce localized clumps in low-slump mixes. When this occurs, a short remix of 3–5 min at high drum speed may clear small balls but may not guarantee full distribution. Production placement records show that fiber addition before water leads to more uniform visual dispersion and fewer pump-blockage events in ready-mix operations.

    When pump and placing boom configurations impose a practical length limit on synthetic reinforcement

    In high-rise or long-distance pumped placements, the 12 mm monofilament is generally compatible with standard concrete pumps, but pump line reducers and elbows require inspection because fiber accumulation can develop at restricted cross-sections. A 12 mm length avoids the severe blockages associated with 19 mm macrofibers in 5-inch or smaller delivery lines. For boom pumps with 125 mm delivery pipe, fibers of this class generally pass through the S-valve and intake grate if the grate openings are at least 50 mm.

    In wet-mix shotcrete, a 12 mm monofilament is often selected because longer fibers can cause nozzle surging and increased rebound. The limitation is that 12 mm does not provide the same post-crack energy absorption as 30–60 mm steel or polymer macrofibers. When toughness or residual strength is specified, beam testing per ASTM C1609/C1609M or EN 14651 must be executed with the proposed dosage before replacing macrofiber reinforcement.

    Compared with fibrillated polypropylene of the same 12 mm length, the monofilament SINTA 12 mm product presents a smooth, closed surface. This lowers the plastic concrete’s apparent dry fiber surface area and reduces the tendency to alter the air-void system. The trade-off is lower mechanical anchoring: fibrillated fibers can split into fine fibrils and increase matrix adhesion, whereas a circular monofilament resists deformation but relies predominantly on frictional bond along the fiber length. The difference becomes measurable in hardened concrete only when fiber volume is high enough to influence post-crack behavior; at the common plastic shrinkage dosage of 0.9–1.5 kg/m³, the difference between monofilament and fibrillated polypropylene in compressive strength is generally within normal batch variation.

    Against steel fibers, the polypropylene monofilament has a density of 0.91 g/cm³ compared with steel’s 7.85 g/cm³; an equal mass of fiber therefore yields a much higher filament count. This provides crack-control efficiency at low mass addition but does not provide meaningful structural stiffness. The elastic modulus of polypropylene is approximately 3.5–4.2 GPa, roughly one-fiftieth of structural steel. Any design relying on stress transfer after matrix cracking should not substitute SINTA 12 mm for steel or macro-polymer reinforcement without explicit structural testing.

    Comparative positioning of Adfil Sinta 12 mm monofilament against alternative fiber classes
    Fiber classGeometryDensityPrimary functionOperational boundary
    Adfil Sinta 12 mm monofilament PP12 mm circular monofilament0.91 g/cm³Plastic shrinkage crack controlNot a replacement for structural reinforcement
    Fibrillated polypropylene microfibre12 mm net or fibrillated film0.91 g/cm³Fine early-age crack controlHigher surface area may reduce slump further
    Alkali-resistant glass fiber6–12 mm chopped strand2.68 g/cm³Early-age crack controlBrittle; requires zirconia-based alkali resistance
    Steel macrofiber30–60 mm hooked-end or deformed7.85 g/cm³Post-crack flexural strengthCorrosion potential and pump-line wear

    Batching, dispersion, and rheology checks in ready-mix operations

    Dosage selection is governed by the required crack-control performance and the ability of the mixer to distribute the fiber uniformly. For 12 mm monofilament polypropylene, common starting dosages are 0.6–1.8 kg/m³; higher dosages up to 3.0 kg/m³ may be specified for industrial slab-on-grade or precast elements but require verification of flowability. Workability can be checked by slump cone per ASTM C143/C143M, inverted slump cone per ASTM C1611/C1611M, or a concrete rheometer for yield stress and plastic viscosity. A drop in initial slump of 10–30 mm is common at these dosages depending on aggregate angularity and the presence of polycarboxylate or naphthalene-based superplasticizers.

    Fiber feed calibration is necessary because the low bulk density of polypropylene monofilament can create overfeeding in volumetric screw conveyors. In plant trials, changing from 12 mm polypropylene to glass fiber or steel fiber requires recalibration of the weigh hopper because the fiber mass per unit volume differs by a factor of three to eight. Batch-to-batch length variation above ±5% may produce visible clumping in high-speed countercurrent mixers; dry-fiber sieve checks and visual inspection of hardened concrete surfaces are low-cost controls.

    At addition levels above 3.0 kg/m³, the fiber volume fraction approaches 0.33% for a polypropylene density of 0.91 g/cm³. The fresh concrete may exhibit a measurable drop in slump and an increase in pump pressure, and some low-cement mixes show fiber balling even with extended mixing time. The transition from 1.8 kg/m³ to 3.0 kg/m³ is therefore a steep processing zone rather than a linear extension of the lower dosage. Trial batching should include a full pump circuit or, at minimum, an inverted slump cone test to detect pumpability issues before the pour.

    Material Classification and CE Marking Documentation

    In the European system, polymer fibres for concrete are divided into Class I microfibers with diameter less than 0.30 mm and Class II macrofibers with diameter equal to or greater than 0.30 mm. Because the SINTA 12 mm monofilament is specified by length rather than cross-section, the Declaration of Performance must be checked to confirm the diameter band. The classification is not administrative only; Class II fibres are evaluated for tensile strength and modulus for structural use, and end users should not assume that a 12 mm length automatically places the product in the microsynthetic category. This distinction affects CE marking and tender specifications that require Class I microfibers for plastic shrinkage control.

    For U.S. specifications, ASTM C1116/C1116M classifies synthetic fiber-reinforced concrete as Type III and does not define a diameter threshold; it requires the fiber to be stable in the mixing environment and the concrete to meet specified properties. The same product may therefore appear differently in different compliance documents. Quality managers should request ISO 9001:2015 batch traceability records, including raw material lot, extrusion line, cut length distribution, and tensile test results.

    Under standard atmospheric conditions, polypropylene fiber does not absorb water, does not corrode, and resists the alkaline pore solution of concrete at pH 12.5–13.5. This chemical stability is not equivalent to thermal stability. Sustained exposure above 80°C or steam curing above 90°C may soften the fiber and reduce its ability to bridge cracks; polypropylene is unsuitable for refractory or autoclave service unless the specific product is qualified by the manufacturer. The fiber is also incompatible with strong oxidizing acids and aromatic solvents, although these species are rarely present in hardened concrete service environments.

    Storage prior to batching should be dry and protected from direct sunlight. Although polypropylene is not hygroscopic, UV exposure can embrittle packaging and lead to contamination by torn film. Pallets should be kept in covered storage; pre-drying of the fiber is not required at relative humidity above 60% because water absorption is below 0.1% by mass, but aggregate moisture correction remains critical because aggregate water content shifts the effective water-to-cement ratio more than the fiber addition.