Liwei Group Co., Ltd

Products

Adfil Sinta 22/12 (SINTA VBA M2212) - Monofilament Polypropylene Microfiber

    • Product Name: Adfil Sinta 22/12 (SINTA VBA M2212) - Monofilament Polypropylene Microfiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 341101
    Material 100% virgin polypropylene
    Fiber Type Monofilament microfiber
    Alkali Resistance Excellent
    Acid Resistance Excellent
    Water Absorption Nil
    Recommended Dosage Kg M3 0.6-1.8
    Color Natural
    Packaging 20 kg bags

    As an accredited Adfil Sinta 22/12 (SINTA VBA M2212) - Monofilament Polypropylene Microfiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Adfil Sinta 22/12 comes in 600 g water-soluble bags, with 20 bags per 12 kg carton.
    Container Loading (20′ FCL) 20′ FCL loading: Adfil Sinta 22/12 (SINTA VBA M2212) monofilament polypropylene microfiber, palletized, moisture-protected, secured, evenly distributed within the container.
    Shipping Adfil Sinta 22/12 (SINTA VBA M2212) monofilament polypropylene microfiber is non-hazardous. It ships as general cargo in moisture-resistant bags or cartons, palletized. It is not classified as dangerous goods under ADR/RID/IMDG/IATA. Store dry, cool, away from direct sunlight and ignition sources. No special transport requirements.
    Storage Store Adfil Sinta 22/12 (SINTA VBA M2212) in original, sealed packaging in a cool, dry, well-ventilated warehouse. Keep away from direct sunlight, moisture, heat, and ignition sources. Place on pallets off the floor; avoid crushing or excessive stacking. Maintain clean, dust-free conditions. Store at ambient temperature. Shelf life is stable when stored properly. No special segregation required under normal conditions.
    Shelf Life Store unopened in a dry, cool area; typical shelf life is 24 months when protected from direct sunlight and moisture.
    Application of Adfil Sinta 22/12 (SINTA VBA M2212) - Monofilament Polypropylene Microfiber

    Cast-in-place industrial floor slab production requires a controlled addition sequence when Adfil Sinta 22/12 (SINTA VBA M2212) monofilament polypropylene microfiber is used at 0.9 kg/m³ to 1.2 kg/m³ in ready-mixed concrete placed by laser screed or power trowel. The product is charged into the mixer after the initial aggregate and water charge has formed a homogeneous paste because the 22 mm monofilament can develop electrostatic clusters when introduced into a dry cement–aggregate blend at relative humidity below 35%, particularly in winter batching plants with heated aggregates. For slab-on-grade and suspended floor mixes with a 20 mm nominal maximum crushed limestone aggregate, the reference concrete for trial batching should contain 320 kg/m³ CEM II/A-LL 42.5 N, 180 kg/m³ water, and a water–cement ratio of 0.48. Restrained plastic shrinkage testing conducted under ASTM C1579-21 on monofilament polypropylene microfiber concrete demonstrates lower crack width index values than an unreinforced reference mix of identical paste volume; published data for the exact M2212 variant in this test configuration is limited, so a plant trial against a reference slab remains the specified verification method before production placement.

    Mixing in a twin-shaft compulsory mixer at 18 rpm to 22 rpm for 5 min after fiber addition is specified to disperse the filaments through the paste without exceeding the shear threshold that can fragment the monofilament and reduce its crack-bridging efficiency. If the fiber is added in the truck mixer on site, the drum must be charged at low speed and mixed for 2 min per cubic metre at mixing speed; charging dry fiber into a rapidly rotating drum causes fiber matting on the hopper and non-uniform distribution. The terminal product in this segment is a hard-trowelled interior logistics floor, an exterior hardstanding, or a suspended slab over metal decking, with crack control requirements tied to joint spacing and exposure classes in EN 206:2013/A2:2021. During finishing, the bleed water must remain on the surface until the first trowel pass; power-trowelling too early presses the top 1–2 mm of paste over fibers and can produce fine surface fuzz that is cosmetically visible under high-gloss coatings without reducing compressive strength.

    Compliance for this application follows EN 14889-2:2006 Class I microfibre with nominal diameter below 0.3 mm and ASTM C1116/C1116M-10a Type III synthetic fiber-reinforced concrete. The polypropylene specific gravity of approximately 0.91 prevents the filaments from settling to the bottom of the slab under normal vibration. Because the microfiber is hydrophobic and inert in the alkaline pore solution at pH 12.5–13.5, it does not participate in the cement hydration reaction and does not require adjustments to the design cover for steel reinforcement. The operational boundary is the mixing moisture state: the product must be stored below 60% relative humidity, and pre-drying is required if bag storage has been exposed to condensation, because damp fibers do not separate in the mixer and can create agglomerates that survive the mixing cycle.

    Table 1. Compliance and test method reference matrix for cast-in-place floor slab applications.

    StandardSubjectRelevant class / parameter
    EN 14889-2:2006Polymer fibres for concreteClause 6.2 Class I microfibre, diameter below 0.3 mm
    ASTM C1116/C1116M-10aFibre-reinforced concrete specificationType III synthetic fibre
    ASTM C1579-21Restrained plastic shrinkage crackingCrack width reduction versus plain reference
    EN 206:2013/A2:2021Concrete specification and conformityConsistence, exposure classes
    EN 13670:2009Execution of concrete structuresCuring class 2 minimum

    What Limits Wet-Mix Nozzle Carrying Capacity at Fibre Doses Above 1.2 kg/m³?

    Rotor-type piston pumps with a 65 mm delivery line and production rates between 8 m³/h and 14 m³/h are the main placement equipment for wet-mix sprayed concrete in tunnel and underground shaft support. At 1.0 kg/m³ of Adfil Sinta 22/12, the high filament count of a 12 µm-class monofilament modifies the paste viscosity without materially changing the pump stroke pressure; at 1.2 kg/m³ and above, nozzle surging becomes observable when the aggregate packing is already optimized for an 8 mm nominal maximum size and the paste volume is below 380 L/m³. Published data for this specific product in wet-mix shotcrete is limited, but the response is consistent with the known relationship between fiber count per cubic metre, paste film thickness on aggregate surfaces, and delivery line resistance in dense-phase pumping.

    Dosage for primary tunnel support and slope stabilization is normally 0.9 kg/m³ to 1.2 kg/m³ when the function is early-age crack control and green cohesion. This range does not replace steel fiber if EN 14487-2:2006 requires post-crack energy absorption above 500 J in panel tests to EN 14488-5:2006. In high-strength sprayed concrete for fire spalling control, the dosage is raised to 2.0 kg/m³ because the polypropylene filaments melt at 160–165 °C and generate interconnected channels for vapour pressure relief when the lining is exposed to hydrocarbon curve fire conditions. The terminal product includes temporary and permanent sprayed concrete linings for road tunnels, rock support in shafts, and erosion-resistant slope shells.

    The fiber is batch-mixed into the wet-mix before it is fed to the pump hopper. Dry addition at the nozzle is not recommended for this monofilament geometry because the low per-filament mass of a polypropylene product with density class 0.9 g/cm³ causes separation in the compressed-air stream and produces locally fiber-rich patches on the receiving surface. In a forced-action pan mixer, batch time of 3–4 min after fiber introduction is sufficient for visual dispersion; the sprayed surface is inspected under oblique light after the first pass for raised nodules that indicate undispersed fiber clumps. When ambient temperature drops below 5 °C or the aggregate moisture content exceeds 3% by mass, the dosage is held at 0.9 kg/m³ until fresh property tests to EN 12350-2:2019 for slump and EN 12350-7:2019 for air content confirm a stable mix.

    Table 2. Sprayed concrete quality control methods under wet-mix application with monofilament PP fibre.

    StandardParameterTypical test point / limit
    EN 14487-2:2006Execution of sprayed concreteCompaction and fibre distribution classes
    EN 14488-5:2006Energy absorptionPanel test after hardening
    EN 12350-2:2019Fresh concrete slumpRecord before pump
    EN 12350-7:2019Air contentTarget 4–6%
    EN 12390-3:2019Compressive strengthCore or panel specimens

    Precast segmental lining production is carried out in automated carousel plants where demoulding occurs at concrete cube strengths of 12–14 N/mm². Edge crumble and lift socket cracking are the primary early-age defects in this segment, and Adfil Sinta 22/12 is dosed at 0.6 kg/m³ to 0.9 kg/m³ into the pan mixer after the fine aggregate and before the cement slurry is discharged from the high-speed slurry mixer. The lower bound is used when external mould vibrators operate at 50–60 Hz and the mix must transfer from the skip into the battery mould without excessive air entrapment; the upper bound is permitted only if the flow of the self-compacting mix remains above 600 mm on the EN 12350-5:2019 flow table.

    Mix design for segmental linings with a 0.34 water–cement ratio and 450 kg/m³ CEM I 52.5 N uses a 10 mm maximum aggregate size, polycarboxylate high-range water reducer at 1.0% by cement mass, and the microfiber at 0.6 kg/m³. Because the 22 mm monofilament is chemically inert, it does not alter the chloride ion migration coefficient measured by NT Build 492; however, trial mixes with the M2212 product are required when the fine aggregate contains more than 12% passing the 0.125 mm sieve, because fiber filaments can reduce filling ability by increasing paste yield stress. Demoulding performance is the functional target: at strengths below 15 N/mm², green concrete is susceptible to brittle tensile failure at sharp mould corners, and the monofilament network bridges microcracks before pull-out at low strain.

    The final product is a segmental tunnel lining ring with a 100-year design service life under EN 1992-1-1 exposure classes XC2 or XD3. The polypropylene monofilament remains inert in the alkaline pore solution and does not generate corrosion staining at segment joints. This application does not use the microfiber as structural reinforcement, and the product must not replace steel bar reinforcement or steel fibers in tensile zones such as radial joints, lifting anchors, or gasket grooves. The specific operational boundary for the precast plant is demoulding at strengths below 8 N/mm²; in that case the fiber dosage is reduced to 0.3 kg/m³ and edge protection is maintained by retarding the mould release process rather than relying on the fiber network.

    When Cementitious Underlayments Are Applied Over Low-Absorption Substrates

    Self-levelling underlayment mixes that are pumped over power-floated concrete, ceramic tile backings, or steel decking tend to retain free water at the interfacial zone when substrate water absorption is below 0.5% by mass. Adfil Sinta 22/12 is incorporated at 0.6 kg/m³ to 0.9 kg/m³ to increase internal surface area and reduce upward free-water migration in thin layers of 3–10 mm. The polypropylene monofilament acts as a distributed bleed control medium rather than as a structural reinforcement, and this dosage range is selected to maintain the self-smoothing action of the mortar without increasing the plastic viscosity beyond the pumping window of a worm pump with 25 mm internal diameter hose.

    The dry formulation for a pumpable underlayment contains 0.35–0.45 water–dry-mortar ratio, 25 kg bagged product, and 0.6 kg/m³ fiber, with a flow target of 280–300 mm on the ring-flow method in ASTM C1708/C1708M-19. Mixing is carried out with a high-shear mixer at 600 rpm for 90 s; the fiber is added to the dry blend before mixing water to prevent hydrophobic surface wetting inhibition. Above 1.0 kg/m³, pumpability through the 25 mm hose may become unstable when the underlayment is applied at a thickness below 5 mm, and the hopper should be fitted with a 6 mm mesh strainer to capture any dry fiber agglomerates. The terminal product is a smoothing and filling layer under vinyl, LVT, epoxy, or ceramic floor coverings, with shrinkage restraint verified by EN 13813:2002 and ASTM C1581/C1581M-18a.

    The microfiber does not contribute to the compressive strength class designation under EN 13813:2002; its function is confined to crack control during the first 24 h. The material specification must therefore list fiber content separately from binder performance, and the specified underlayment thickness must not be reduced because of the presence of fibers. Air content should be measured to EN 1015-7 when the mix is combined with polymer powder modification, because the monofilament can stabilise entrained air bubbles under high-shear mixing and shift the hardened density if mixer speed is not controlled across successive batches.

    Machine-applied repair mortars and grouts depend on thixotropic yield stress for overhead placement and on low bleed for bond strength. Adfil Sinta 22/12 is incorporated at 0.3 kg/m³ to 0.5 kg/m³ in non-shrink grout and at 0.6 kg/m³ in machine-applied R4 repair mortar conforming to EN 1504-3:2005. The lower dosage in grout preserves capillary suction at the prepared concrete substrate; overdosing above 0.5 kg/m³ can reduce substrate wetting and may require a lower-solids primer to maintain the specified adhesion strength. In repair mortars, the 0.6 kg/m³ dosage controls plastic settlement cracks at the interface of horizontal and vertical repair patches without reducing the thixotropic buildup required for overhead spraying.

    The mixing sequence is specific to the delivery method. Dry components including 0.6 kg/m³ of the 22/12 monofilament are pre-blended for 60 s in a horizontal shaft paddle mixer at 30 rpm; water is then added over 30 s at low speed, followed by high-speed dispersion at 600 rpm for 2 min. Spray application through a worm pump with a 15 mm nozzle and 2.5 bar compressed air deposits a dense paste rather than a high-velocity stream, which eliminates the rebound losses seen in dry-spray repair materials. The terminal product is an EN 1504-3 Class R4 structural repair layer applied in 10–20 mm lifts, or a non-structural surface fairing layer at 3–5 mm thickness where crack bridging is not the design intent.

    Compliance for the repair segment references EN 1504-3:2005 for structural and non-structural repair mortars and ASTM C1581/C1581M-18a for restrained shrinkage of mortar. Polypropylene monofilament is inert with styrene–butadiene rubber and acrylic polymer powders used in repair mortars; polymer film formation at 23 °C and 50% RH proceeds unaffected. The microfiber does not conduct current and does not compromise the passivity of reinforcing steel when the repair is applied to chloride-contaminated concrete after substrate preparation. It is not a substitute for reinforcing bars where the structural design requires load transfer across the repair boundary, and it should not be used as the sole reinforcement in a patch that must satisfy load-bearing capacity under EN 1504-3:2005 structural requirements.

    Low-Slump Dry-Cast Pipe Reinforcement and the Function of 22 mm Cut Length

    Dry-cast pipe machines operate at zero slump and rely on immediate demoulding after vibro-compaction. The steepest process risk is vertical demoulding fracture when the green pipe is lifted from the core and outer jacket. Adfil Sinta 22/12 is distributed through the zero-slump mix at 0.4 kg/m³ to 0.7 kg/m³, with the upper bound reserved for pipe diameters above 600 mm and wall thickness below 100 mm. At these dosages the monofilament bridges plastic settlement cracks around the reinforcing cage during compaction but does not interfere with the mechanical bond between steel reinforcement and the dry-cast matrix.

    Mixing is carried out in a planetary mixer at 12–15 rpm for 90 s after fiber addition. The free-water content is held between 6.5% and 8.0% by mass of cement, and compaction is achieved by eccentric vibration at 60–65 Hz for 12–18 s. The 22 mm cut length is more effective than fibers below 12 mm at bridging cracks that initiate at the tip of the compaction head, while fibers above 30 mm would have a higher probability of wrapping around the vibration shaft and forming localized fiber nests. The terminal products include stormwater and sanitary sewer pipes conforming to EN 1916:2002/AC:2008, jacking pipes, culverts, and manhole riser sections. Wet and dry acceptance testing follows ASTM C497-20; the presence of the microfiber does not change the specified hydrostatic leakage limit for the pipe class.

    Polypropylene monofilament is hydrophobic, so water absorption of the dry-cast matrix is not affected at the stated dosages; this is relevant for frost-resistant pipe classes tested to CEN/TS 12390-9:2016. Field data on freeze–thaw salt-scaling resistance of M2212-containing dry-cast pipe is limited, and plant-specific trial mixes are recommended where exposure class XF3 or XF4 applies. The fiber is added after the aggregate but before the water to avoid hydrophobic floating on the mix surface during planetary mixing; if the plant uses recycled slurry water, the fiber dosage should be checked against the higher solids content because the filament can interact with the slurry and reduce the compacted green strength at dosages above 0.7 kg/m³.

    Free Quote

    Competitive Adfil Sinta 22/12 (SINTA VBA M2212) - Monofilament Polypropylene Microfiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    The Adfil Sinta 22/12 (SINTA VBA M2212) is a monofilament polypropylene microfiber supplied for dispersion in portland cement concrete, mortar, and screed systems. The product designation identifies a nominal filament diameter of 22 µm and a nominal cut length of 12 mm, giving an aspect ratio of approximately 545:1. The base polymer has a specific gravity of 0.91 g/cm³ and a melting point typically within 160–165 °C, which remains above normal cement hydration temperatures but below the thermal conditions reached in autoclaved aerated concrete production. As a monofilament, the fiber is composed of discrete cylindrical filaments rather than a fibrillated or collated network. This physical form influences both the fiber count per unit mass and the spacing factor in the fresh cementitious matrix. The fiber is assigned to Class II polymer fiber under EN 14889-2:2006 and falls within Type III synthetic fiber reinforcement under ASTM C1116/C1116M-23. Its primary function is the reduction of plastic shrinkage cracking, settlement cracking, and early-age surface distress, not the provision of structural post-crack load capacity.

    The nominal tensile strength of monofilament polypropylene fibers in this diameter class is commonly reported between 300 MPa and 450 MPa, with an elastic modulus of 3.5–4.5 GPa and elongation at break in the range 15–30%. These values indicate that the fiber improves crack resistance during the plastic and very early hardening stages but does not replace steel reinforcement, welded wire mesh, or structural macrofibers after the concrete matrix has cracked. The exact tensile properties of SINTA VBA M2212 should be taken from the manufacturer’s initial type testing under EN 14889-2:2006; published data for this specific configuration is limited.

    When 12 mm Monofilament Is Introduced into a 0.45 w/c Concrete Matrix

    Plastic shrinkage cracking in concrete with water-to-cement ratios between 0.40 and 0.50 is driven by capillary pressure when the evaporation rate at the surface exceeds the bleed rate. The addition of 12 mm monofilament at dosages from 0.9 kg/m³ to 1.8 kg/m³ has been evaluated in restrained slab tests following ASTM C1579-21, where the fibers interrupt capillary channel coalescence and reduce the width and cumulative length of plastic shrinkage cracks. The mechanism is physical rather than chemical; polypropylene does not materially alter portland cement hydration stoichiometry or setting time under normal conditions. At a dosage of 1.8 kg/m³, the fiber volume fraction is approximately 0.20%, and the product of volume fraction and aspect ratio, sometimes called the fiber factor, approaches 1.1. This is a practical boundary above which flow loss and mixing difficulty tend to increase without proportional additional plastic shrinkage benefit.

    At 22 µm diameter and 12 mm length, the calculated fiber count is approximately 2.4 × 10⁸ filaments per kilogram, with a specific surface area near 200 m²/kg. The high specific surface area contributes to water demand and the formation of a paste-fiber interfacial zone. In concretes with a slump class of S3 to S4, dosages above 1.5 kg/m³ may reduce slump by 20–40 mm; the magnitude depends on aggregate angularity, cement paste volume, and the use of polycarboxylate or lignosulfonate water-reducing admixtures. Measurements under ASTM C143/C143M-20 should be performed before and after fiber addition to quantify the plant-specific workability correction.

    The threshold evaporation rate at which plastic shrinkage cracks become probable is not a fixed value. Slab geometry, concrete bleed rate, wind speed, and ambient temperature all influence the result. The fiber shifts the cracking threshold by reducing maximum crack width and interrupting crack coalescence rather than by eliminating surface evaporation. In concrete produced with 0.45 water-to-cement ratio and well-graded aggregates, the use of fibers does not replace moist curing under ASTM C31/C31M-24 or the application of a membrane curing compound.

    Mixer charging sequence and moisture conditions govern whether the product disperses as individual filaments or forms agglomerates. In forced-action pan mixers with rotor speeds of 15–25 rpm, fiber addition into dry aggregate before water can produce electrostatic clustering and uneven distribution; therefore, the fiber is charged after aggregates have been wetted but before final discharge. A high-shear dispersion interval of 60–90 s after fiber introduction is normally sufficient to break up minor entanglement. Extended mixing beyond 120 s does not improve uniformity and may increase fiber surface attrition, particularly in mixes containing angular crushed aggregate. The hydrophobic polypropylene surface does not require pre-drying for concrete production; however, the product should be stored dry and away from prolonged direct UV exposure. Continuous service temperatures exceeding 100 °C are not recommended because the elastic modulus of polypropylene declines substantially as the melting point is approached.

    Truck mixer discharge data on production loads indicate that at least 70 revolutions at mixing speed after fiber addition is required for visual dispersion in 6 m³ to 8 m³ loads. Batch-to-batch variance in short-screw dry-mix conveying has been observed when fiber content exceeds 1.5 kg/m³, because the low bulk density of the fiber can delay hopper discharge. Pre-blending the fiber with sand at the bag plant reduces this variance in machine-applied screeds.

    Does the VBA M2212 Designation Alter Rheological Boundaries in Pumped Screeds?

    The addition of a 22 µm × 12 mm monofilament raises flow resistance in pumpable screeds in proportion to fiber volume fraction and aspect ratio. At volume fractions between 0.1% and 0.3%, corresponding approximately to 0.9 kg/m³ and 2.7 kg/m³, the effect on mortar flow measured under DIN EN 1015-3 is small at the lower bound but increases sharply above 1.8 kg/m³. The exact reduction in flow table spread is not a universal parameter; it depends on cement paste volume, sand grading, and superplasticizer chemistry. Published data for this specific configuration in machine-applied screeds is limited, but field measurements on similar monofilament polypropylene fibers commonly require a water-to-powder ratio increase of 0.01 to 0.03 or a superplasticizer dosage increase of 0.2–0.5% by cement mass to restore pumpability. The fiber does not alter the hydration kinetics measured by isothermal calorimetry; its effect on rheology is therefore treated as an additive physical constraint rather than a chemical accelerant or retarder. No chemical incompatibility with common cement admixtures has been reported for polypropylene, but producers should verify compatibility of the total admixture system under production temperatures.

    Fire Spalling Resistance and Alkali Durability in EN 14889-2 Class II Systems

    In high-strength concrete with water-to-binder ratios below 0.35, the dense hardened matrix has low permeability and limited pore space for vapor expansion during fire. Monofilament polypropylene microfibers provide passive fire spalling control by melting in the range 160–170 °C and decomposing at higher temperatures, leaving percolated microchannels that allow vapor pressure to dissipate. The 22 µm diameter and high filament count per kilogram generate a distributed network of channels after thermal exposure. Dosages for fire protection are typically higher than those for plastic shrinkage control and may be specified between 1.5 kg/m³ and 3.0 kg/m³ in tunnel lining concretes, but the applicable dose must be validated by fire tests on the actual concrete composition. Compliance with EN 14889-2:2006 Class II requires initial type testing of geometry, tensile strength, and alkali resistance and establishes factory production control obligations; it does not itself certify fire performance. Polypropylene exhibits high resistance to alkaline environments with pH values up to 13.5, which makes it suitable for long-term incorporation in hydrated cement paste. For fire resistance, published data on this exact SINTA VBA M2212 configuration is limited; qualification therefore relies on component-specific or project-specific testing under the relevant fire curve.

    ParameterNominal or Typical ValueReference / Classification
    Product designationAdfil Sinta 22/12 (SINTA VBA M2212)Manufacturer identification
    Fiber typeMonofilament polypropylene microfiberClass II polymer fiber
    Nominal filament diameter22 µmEN 14889-2:2006
    Nominal cut length12 mmEN 14889-2:2006
    Specific gravity0.91 g/cm³Base polymer typical
    Melting point160–165 °CBase polymer typical
    Tensile strength300–450 MPa (typical class; exact manufacturer initial type testing)Initial type testing
    Elastic modulus3.5–4.5 GPaBase polymer typical
    Water absorption<0.1%Hydrophobic polymer property
    Standards classificationEN 14889-2:2006 Class II; ASTM C1116/C1116M-23 Type IIIRegulatory / material specification

    The principal difference between this product and a fibrillated polypropylene microfiber is the dispersed state after mixing. A fibrillated product opens into a network of interconnected fibrils under high shear, whereas this monofilament remains as individual cylindrical filaments. The monofilament therefore provides a higher count of small-diameter elements per kilogram and more uniform spacing in low-viscosity paste, but it may be more sensitive to clumping if charged too early into a dry mixer. Compared with structural synthetic macrofibers of 0.5–1.0 mm diameter and 30–60 mm length, the 22 µm × 12 mm monofilament does not provide meaningful post-crack flexural capacity and should not be substituted for steel reinforcement, welded wire mesh, or structural macrofibers in hardened concrete crack-width control. The elastic modulus of polypropylene, typically 3.5–4.5 GPa, is lower than that of steel at approximately 200 GPa and lower than many polyvinyl alcohol structural fibers at 25–40 GPa. However, the hydrophobic nature and alkali resistance of polypropylene provide a durability advantage over cellulose and polyester microfibers in wet alkaline cementitious matrices.

    CharacteristicAdfil Sinta 22/12 (SINTA VBA M2212)Fibrillated PP microfiberStructural synthetic macrofiber
    Geometry22 µm × 12 mm monofilamentFibrillated network, variable opening under shear0.5–1.0 mm diameter, 30–60 mm length
    Primary functionPlastic shrinkage and early-age crack controlPlastic shrinkage controlPost-crack load transfer and structural crack-width control
    Fiber count per kgApprox. 2.4 × 10⁸Moderate; dependent on fibrillationLow
    Effect on hardened flexural toughnessNot significantNot significantSignificant at appropriate dosage
    Alkali resistanceHighHighHigh
    Standards classificationEN 14889-2:2006 Class II; ASTM C1116/C1116M-23 Type IIIClass II / Type III depending on productClass I / Type III or Type V depending on product

    The product is not intended for structural reinforcement, and dosage rates for a given application should be determined by trial mixes using the same mixer, aggregate source, and water-reducing admixture system intended for production.