| HS Code | 923587 |
| Product Name | Adfil Sinta 28/12 (Syntec 12) |
| Material | 100% Polypropylene |
| Fiber Type | Monofilament Microfiber |
| Fiber Length | 12 mm |
| Fiber Diameter | 28 µm |
| Aspect Ratio | 428:1 |
| Density | 0.91 g/cm³ |
| Tensile Strength | 400 MPa |
| Young S Modulus | 3500 MPa |
| Elongation At Break | 20% |
| Melting Point | 165 °C |
| Ignition Point | >400 °C |
| Water Absorption | <0.1% |
| Alkali Resistance | Excellent |
| Acid Resistance | Excellent |
| Uv Resistance | Excellent |
| Dosage | 0.9 kg/m³ typical |
| Color | Natural White |
| Packaging | 0.9 kg bags, 18 kg carton |
| Standards | EN 14889-2, ASTM C1116 |
As an accredited Adfil Sinta 28/12 (Syntec 12) - Monofilament Microfiber, 100% Polypropylene factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied as 600 g water-soluble bags, 20 bags per carton, totaling 12 kg, for direct concrete addition. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): Adfil Sinta 28/12 (Syntec 12) monofilament microfiber, 100% polypropylene, palletized, shrink-wrapped, and securely loaded for export. |
| Shipping | Adfil Sinta 28/12 (Syntec 12), monofilament microfiber, 100% polypropylene, is non-hazardous and not classified as dangerous goods. It is typically packaged in moisture-resistant bags or cartons, palletized, and shrink-wrapped. Store in a dry, clean area away from direct sunlight and ignition sources; handle with standard warehouse equipment. |
| Storage | Store Adfil Sinta 28/12 (Syntec 12) monofilament microfiber in original, sealed packaging in a cool, dry, well-ventilated warehouse. Keep away from direct sunlight, moisture, heat, and ignition sources at ambient temperature. Place on pallets off the floor, avoid contamination, and use first-in, first-out rotation. Protect bags from punctures, crushing, and water; keep labels legible. No special ventilation required. |
| Shelf Life | Indefinite when stored dry, cool, away from UV and moisture, in unopened original packaging; polypropylene fiber has no expiration. |
Adfil Sinta 28/12 (Syntec 12), a 12 mm monofilament 100% polypropylene microfibre with an equivalent fibre diameter of approximately 28 µm, is added to ready-mix concrete for slab-on-grade construction at a dosage of 0.6 kg/m³ to 1.0 kg/m³. The fibre is dispensed into the aggregate weigh hopper or onto the aggregate transfer belt before cementitious powder addition. A twin-shaft batch mixer with dry mixing capability is preferred; monofilament fibres require full dispersal momentum before the mixing water reaches the fibre surface. Mixing time after all materials are charged is typically extended by 90 s to 120 s to eliminate visual clumping. The relevant specification is ASTM C1116/C1116M for fibre-reinforced concrete, with plastic shrinkage cracking assessed under ASTM C1579. Slump measured to ASTM C143/C143M may decrease by 10 mm to 20 mm at the upper dosage. A polycarboxylate ether superplasticizer conforming to EN 934-2 is therefore used when the base mix is designed near the lower workability boundary. Air content determined by ASTM C231/C231M is held at 2 % to 4 % for non-freeze-thaw interior slabs. The fibre does not itself entrain air. Placement by laser screed and finishing with ride-on power trowels produce the terminal industrial logistics floor. The operational boundary is that microfibre addition does not replace structural reinforcement or modify the engineered saw-cut joint layout.
In precast architectural panels, Adfil Sinta 28/12 is batched at 0.6 kg/m³ to 0.9 kg/m³ into a mix conforming to EN 206 and executed under EN 13369. The fibre is introduced into a pan mixer after 60 s of dry aggregate mixing and before 70 % of the gauging water is added. This sequence prevents hydrophobic polypropylene filaments from floating to the surface during wet mixing. Flow is measured on the EN 12350-5 flow-table spread, which typically falls by 20 mm to 40 mm when the dosage moves from 0.6 kg/m³ to 0.9 kg/m³. Demoulding of face-mix elements at cylinder strengths of 26 MPa to 32 MPa is not delayed by the fibre. Edge spalling during mould release is reduced because the microfibres bridge microcracks in the fresh surface layer. The CE marking record is supported by EN 14889-2:2006 for polymer fibres in concrete, with declared properties limited to plastic shrinkage control. The terminal products are storey-height facade panels and spandrel units. The operational limit is that fibre addition does not increase hardened-state structural tensile strength; lifting anchors and reinforcement remain load-bearing components.
Shotcrete tunnel lining mixes containing Adfil Sinta 28/12 require a dosage of 1.0 kg/m³ to 1.5 kg/m³ in both dry-process and wet-process application. In dry-process spraying, the fibre is pre-blended with cement and aggregate before the nozzle water ring. In wet-process material conforming to EN 14487-1, the fibre is dosed into the transit mixer. The 12 mm fibre length is retained on the rebound stream less than longer steel fibre, but rebound percentage remains governed by nozzle angle, air pressure, and water content rather than fibre addition alone. Published data for this specific configuration is limited. Compressive strength tested to EN 12390-3 is not affected at these dosages. Flexural toughness to EN 14488-3 shows no structural contribution above the unreinforced reference. Pumping pressure in wet-process lines with 50 mm to 80 mm internal diameter hoses may rise by 5 % to 10 % compared with plain shotcrete; the pump manufacturer should be consulted before batching. The terminal product is a temporary support lining immediately after excavation, used before installation of the final cast-in-situ or segmental lining. The operational boundary is that the microfibre is not a substitute for steel fibre or mesh where ground loads require post-crack flexural capacity.
For cementitious and blended calcium sulfate self-levelling underlayments governed by EN 13813, Adfil Sinta 28/12 is incorporated at 0.6 kg/m³ to 0.9 kg/m³ during continuous mixing in a single-chamber forced-action mixer. Because the material is a hydrophobic monofilament, the fibre is first pre-dispersed into the dry binder via a screw feeder to avoid hydrophobic clusters when the water/solids ratio is below 0.40. The fresh mortar is pumped through 25 mm to 35 mm internal diameter rotor/stator pumps. Pump pressure remains stable if the fibre has been dry-premixed. Flow-ring spread to EN 12706 is specified at 250 mm to 300 mm; microfibre addition can reduce initial spread by 10 mm to 15 mm. This loss is corrected with a small increase in superplasticizer dosage within the manufacturer’s permitted range. The fibre reduces plastic settlement cracking over heated floors and over non-absorbent substrates. The terminal products are residential and commercial floor toppings of 3 mm to 30 mm thickness. The limiting condition is that fibres do not compensate for substrate deflection, and the installed layer remains a bonded or floating screed requiring movement joints at threshold zones.
| Downstream application | Dosage (kg/m³) | Primary standard | Mixing equipment |
|---|---|---|---|
| Industrial slab-on-grade | 0.6–1.0 | ASTM C1116/C1116M | Twin-shaft batch mixer |
| Precast architectural panels | 0.6–0.9 | EN 14889-2:2006 | Pan mixer |
| Shotcrete tunnel lining | 1.0–1.5 | EN 14487-1 | Dry-process gunite or wet-process pump |
| Self-levelling underlayment | 0.6–0.9 | EN 13813 | Forced-action continuous mixer |
On bridge decks and pavement rehabilitation projects, thin bonded overlays with Adfil Sinta 28/12 are produced at 0.9 kg/m³ to 1.2 kg/m³ in high-early-strength latex-modified or silica-fume overlay concrete. The overlay mix is specified to ASTM C928/C928M for rapid hardening repair materials and mixed in a mobile continuous mixer at the job site. The 12 mm fibre length is below the minimum overlay thickness of 25 mm to 50 mm, allowing trowel or screed finishing without protruding fibres. Plastic shrinkage cracks on high-wind, low-humidity days are controlled because the monofilament network increases the fresh mix’s resistance to capillary tensile stress. The relevant test method is ASTM C1579. The fibre does not affect overlay bond to the substrate, which remains a function of surface preparation by shotblasting or milling to a minimum CSP 5 profile per ICRI Guideline 310.2R. Terminal products are bridge deck overlays and ramp wearing surfaces. The operational boundary is that microfibre addition does not increase structural flexural capacity and does not reduce the need for wet curing; membrane curing compound is still applied at the specified coverage rate.
Repair mortars conforming to EN 1504-3 are dry-blended with Adfil Sinta 28/12 at 0.5 kg/m³ to 0.8 kg/m³ into polymer-modified, shrinkage-compensated formulations. The mixing procedure uses a slow-speed paddle mixer at 400 rpm to 600 rpm for 3 min after the entire powder is added to the gauging water. Wetting the fibre first or adding fibre to water creates balls. The mortar is applied by trowel or spray in layers up to the product-specific maximum thickness, typically 20 mm to 40 mm per pass. The fibre reduces plastic cracking in thick trowel applications where surface evaporation exceeds bleeding. Fresh-mortar cracking is evaluated under ASTM C1579 or the test methods referenced in EN 14889-2. Compressive strength development to EN 12190 is not altered at these dosages. Adhesion to substrate measured by EN 1542 remains dependent on substrate saturation and roughness. The terminal products are structural and non-structural patch repairs on beams, columns, and balcony edges. The incompatibility boundary is the use with air-entraining mortars at dosages above 0.8 kg/m³; the combined effect on air void spacing factor may reduce frost resistance.
Machine-applied cement-lime renders are produced with Adfil Sinta 28/12 at 0.5 kg/m³ to 0.8 kg/m³ in silo-mixed dry mortar. The fibre is pre-mixed into the dry mortar in a high-shear continuous ploughshare mixer before water is added at the spray lance. A 12 mm monofilament length is below the typical 10 mm to 25 mm render thickness, so surface texture is not compromised. The fibre network reduces plastic shrinkage cracks during hot, dry wind conditions on open facades; the performance indicator is restrained drying shrinkage testing adapted from ASTM C1579 for mortar. Water retention measured to EN 1015-8 and consistency measured to EN 1015-3 are not significantly changed at the lower dosage. The terminal products are external render systems over concrete, blockwork, and lightweight panels. The operational limitation is that fibre addition does not prevent cracks originating from substrate movement, and is not a replacement for movement joints or basecoat reinforcement mesh in vulnerable areas.
Competitive Adfil Sinta 28/12 (Syntec 12) - Monofilament Microfiber, 100% Polypropylene prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Adfil Sinta 28/12 (Syntec 12) is specified as a 28 µm nominal monofilament diameter, 12 mm cut length, 100% polypropylene microfibre for cementitious matrices. The parenthetical reference Syntec 12 identifies the 12 mm length series within the supplier’s monofilament range, not a separate polymer system. The base polypropylene homopolymer used in this fibre class has a density of 0.90–0.91 g/cm³ when measured under ISO 1183-1:2019, a melt transition in the range 160–170°C under ISO 11357-3:2018, and a saturated hydrocarbon backbone that is not susceptible to alkaline hydrolysis in the pH 12.5–13.5 pore solution of portland cement. The product is intended for plastic shrinkage crack control in concrete, mortar, screed, precast, and shotcrete; it is not primary reinforcement.
At 0.9 kg/m³, the polypropylene volume fraction is approximately 0.1 vol%, placing the product within the conventional microfibre band for low-volume crack control. The theoretical specific surface area of a 28 µm circular filament at 0.91 g/cm³ is approximately 157 m²/kg. This high surface-to-volume ratio explains the measurable influence on fresh-state water demand, segregation, and dispersion. These values are derived from geometry and density, not from destructive testing, and should be checked against the current manufacturer’s dosage guidance.
The 28 µm diameter and 12 mm length generate a theoretical fibre count of approximately 1.5 × 10⁸ fibres per kilogram. A 0.9 kg/m³ dose therefore introduces on the order of 1.3 × 10⁸ discrete fibres into each cubic metre of concrete. This is orders of magnitude higher than the 10⁴–10⁵ fibres per kilogram typical for 0.5–1.0 mm steel macrofibres. High fibre count improves distribution density but does not automatically guarantee crack control; balling, paste volume, and mixing energy are limiting variables. The designation also controls cut length. At 12 mm, the fibre is long enough to bridge fine plastic-shrinkage openings but short enough to be handled in standard aggregate batchers and worm-screw dispensers.
At the same addition mass, the product has a greater number of fibres than longer macrofibres, but each individual fibre has low stiffness. Tensile modulus for unmodified polypropylene filament is typically 3.5–4.5 GPa; tensile strength is typically 300–500 MPa. These are class-typical values for polypropylene monofilament, not lot-specific acceptance limits. A lower aggregate cement ratio or low paste volume can expose the additional surface area as a drop in slump under EN 12350-2; the effect is most pronounced above 1.2 kg/m³ without a plasticizer.
Plastic shrinkage cracking occurs when the evaporation rate from fresh concrete exceeds the bleed-water supply, producing capillary tensile stress while the matrix has little tensile capacity. In restrained slab trials under ASTM C1579-21, monofilament microfibres in the 0.6–1.2 kg/m³ range have been reported to reduce crack width and total crack area relative to plain concrete. Published data for this specific configuration is limited; exact crack-reduction ratios depend on admixture chemistry, cement fineness, wind speed, and form geometry. Trial batching is therefore required before a performance-based specification is fixed. Because the fibres obstruct some bleed channels, bleeding may also decrease; bleed rate should be measured under ASTM C232/C232M-21 when evaporation conditions are severe. This shift can increase plastic shrinkage risk if curing or evaporation control is not adjusted.
The product is also used in dry-mix shotcrete at dosages of 0.9–1.8 kg/m³, where the low density of polypropylene limits pumping and nozzle-blocking tendencies compared with rigid steel fibres. Shotcrete consistency and rebound should be assessed through EN 14487-1. In thin-section precast elements, the fibre reduces surface cracking during demoulding and early curing, but it does not provide edge protection against impact or transport damage.
On twin-shaft compulsory mixers with 30–60 s dry mixing, the addition sequence affects fibre distribution. Field reports indicate that the monofilament is best introduced with fine aggregate or through a calibrated screw conveyor at the start of dry mixing, not after large volumes of mixing water have created a low-shear slurry. Water should be added only after the fibres are distributed through the aggregate. After water contact, a minimum wet mixing time of 60 s is typical for full random orientation, but high-speed pan and planetary mixers may require shorter or longer cycles depending on blade condition and batch size. The material should not be dumped from a torn bag directly into a stationary centre pocket; this creates high local fibre concentration and agglomeration.
Fibre balling on site is often misinterpreted as a material defect when the true cause is addition sequencing. The product’s high theoretical fibre count, approximately 1.5 × 10⁸ filaments/kg, means that a 25 kg bag contains a very large population of discrete filaments. If the mixer has insufficient shear or the batch is overloaded, the fibres cannot separate into individual units. Dispersibility should be checked at the plant by washing a 1 kg composite sample over a 0.5 mm sieve and counting agglomerated fibre balls. For wet-cast flowable mixes, addition after coarse aggregate and before final water adjustment often reduces drawdown because the aggregate assists distribution without requiring continuous high-energy mixing. In transit-mixer operations, adding fibres to the conveyor with the aggregate or through the water ring is preferable to dropping bags into the drum after all materials are wet. A dry aggregate pre-mix of 2 min at low drum speed followed by 5 min at mixing speed is a common starting point, but this cycle is mixer-dependent and must be confirmed by wash-out inspection.
Water-soluble or kraft paper bags, if supplied, should be added unopened only when the packaging material is confirmed to disintegrate at the available mixer water temperature. Packaging that does not dissolve can produce large agglomerates that are difficult to separate later.
Design substitution of steel macrofibre is not permitted for load-bearing post-crack performance. Steel macrofibres with 0.5–1.0 mm diameter and 30–60 mm length are specified when residual flexural tensile strength is required through EN 14845-1:2006 or ASTM C1609/C1609M-19a. Polypropylene monofilament has a much lower modulus, typically 3.5–4.5 GPa versus 200 GPa for steel, and creeps under sustained load; it cannot maintain post-crack opening resistance in hardened concrete. The product may reduce plastic shrinkage crack visibility, but it shall not be used as a substitute for reinforcing bars, structural wire mesh, steel macrofibre, or engineered synthetic macrofibre in slabs designed under EN 1992-1-1.
The difference also appears in hardened flexural testing. In ASTM C1609/C1609M-19a, a beam containing only micro-PP typically exhibits a residual strength ratio close to zero after first crack because the low-modulus fibres pull out without contributing significant load. Steel macrofibres are able to bridge cracks up to several millimetres. Therefore, project specifications that quote fR,1k or fR,4k values from EN 14845-1 should exclude this product unless the structural designer has explicitly accepted a non-structural crack-control function.
Polypropylene microfibre also differs from fibrillated polypropylene microfibre. The fibrillated form is produced from oriented film and opens into an irregular netlike cross-section during mixing. The circular monofilament in the 28/12 class has a more predictable cross-sectional area and may disperse more readily in low-slump mixtures, but it provides fewer mechanical interlock sites than an opened fibrillated network. Compared with PVA microfibre, polypropylene is hydrophobic and does not compete for mixing water, whereas PVA has higher tensile strength and modulus and is used in strain-hardening cementitious composites at much higher volume fractions. Compared with alkali-resistant glass fibre, polypropylene requires no alkali-resistant coating for use in portland cement, but its low modulus excludes it from thin-section applications requiring high first-crack strength.
Comparative differences are summarized in the matrix below. The values shown are class-typical ranges drawn from public polymer and fibre literature for the fibre types, not lot-specific acceptance limits.
| Property | Sinta 28/12 class | Fibrillated PP microfibre | PVA microfibre | Steel macrofibre |
|---|---|---|---|---|
| Material type | 100% polypropylene monofilament | 100% polypropylene fibrillated film | Polyvinyl alcohol | Low-carbon steel wire |
| Density | 0.90–0.91 g/cm³ | 0.90–0.91 g/cm³ | 1.28–1.30 g/cm³ | 7.85 g/cm³ |
| Geometry | 28 µm diameter × 12 mm | Fibrillated network; equivalent length 12 mm | 40–200 µm diameter × 12 mm | 0.5–1.0 mm diameter × 30–60 mm |
| Tensile modulus | 3.5–4.5 GPa | 3.5–4.5 GPa | 25–40 GPa | 200 GPa |
| Tensile strength | 300–500 MPa typical for PP monofilament | 300–500 MPa typical for PP | 1000–1600 MPa | 1000–1500 MPa |
| Primary function | Plastic shrinkage crack reduction | Plastic shrinkage crack reduction and green-state crack bridging | Micro-crack bridging in high-ductility mortars | Post-crack residual flexural and shear toughness |
| Relevant standard | EN 14889-2:2006, ASTM C1116/C1116M-23 | EN 14889-2:2006 | ASTM C1116/C1116M-23 | EN 14845-1:2006 |
The most consequential difference in formulation is hydrophobicity. Polypropylene does not absorb mixing water, unlike PVA or natural cellulose fibres, and therefore does not compete with cement for water during hydration. This reduces early-age mix-water adjustment but also means that the fibre relies on mechanical dispersion and surface finish for suspension, not on swelling or hydrophilic interaction.
Pre-drying of the product is not normally required because polypropylene is hydrophobic; however, wet packaging or exposure to rain can create fibre clumps that resist mechanical separation. If surface moisture has caused agglomeration, the material should be dried below 60°C or replaced. Continuous service in cementitious matrices is generally below 90°C, which is safely below the polymer melt transition; the product is not recommended for autoclave curing regimes above 150°C because filament softening and shrinkage may occur. Solvent-based curing compounds applied to surface-exposed fibres should be checked for compatibility because polypropylene is soluble or swelling in some aromatic and chlorinated solvents.
Bags should be stored off the ground in dry conditions below 40°C, protected from direct sunlight. Loose fibres exposed to ultraviolet light for extended periods may undergo surface embrittlement before incorporation; once embedded, the cementitious matrix blocks UV radiation. The product has negligible electrical conductivity and is not intended for use in conductive floor toppings or where the concrete is required to conduct current. No reactive incompatibility with ordinary portland cement, ground granulated blast-furnace slag, or fly ash is known, but combinations with high dosages of air-entraining admixtures can shift the air-void system and require updated trial batches under EN 12350-7 or equivalent.