    • Product Name: Adfil Sinta M1819 - Virgin Polypropylene Monofilament Micro Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 643078
    Material Virgin Polypropylene
    Fiber Type Monofilament Micro Fiber
    Length 18 mm
    Diameter 19 microns
    Aspect Ratio 947
    Density 0.91 g/cm3
    Tensile Strength 500 MPa
    Elastic Modulus 3500 MPa
    Melting Point 160 °C
    Alkali Resistance Excellent
    Water Absorption Nil
    Color Natural/White

    As an accredited Adfil Sinta M1819 - Virgin Polypropylene Monofilament Micro Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Adfil Sinta M1819 micro fiber is supplied in 20 kg moisture-resistant bags, palletized and shrink-wrapped for secure industrial handling.
    Container Loading (20′ FCL) 20′ FCL container loaded with Adfil Sinta M1819 virgin polypropylene monofilament micro fiber, palletized in bags, securely stowed for transport.
    Shipping Adfil Sinta M1819 Virgin Polypropylene Monofilament Micro Fiber is non-hazardous and not classified as dangerous goods for transport. Supplied in sealed bags/cartons on pallets, shrink-wrapped. Store dry, clean, away from direct sunlight and ignition sources. No UN number, hazard class, or marine pollutant designation applies.
    Storage Store Adfil Sinta M1819 in its original, unopened packaging in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, open flames, and moisture. Place pallets on clean, dry surfaces, off the ground. Protect bags from punctures and contamination. Maintain good housekeeping to minimize dust. Use first-in, first-out stock rotation. Avoid excessive stacking and prolonged UV exposure.
    Shelf Life Shelf life is indefinite if stored dry, sealed, and protected from UV, moisture, and contaminants; performance remains stable for years.
    Application of Adfil Sinta M1819 - Virgin Polypropylene Monofilament Micro Fiber

    Ready-mixed concrete for slab-on-grade and suspended floor construction represents the largest volume application for Adfil Sinta M1819. The fibre is a virgin polypropylene monofilament micro fibre with a nominal cut length of 19 mm and an equivalent diameter below 30 μm. The primary function is control of plastic shrinkage cracking during the first 6 h to 12 h after placement. A typical addition range is 0.6 kg/m³ to 0.9 kg/m³. At this dosage the fibre acts as a Type III synthetic fibre under ASTM C1116/C1116M, not as primary structural reinforcement. Early-age cracking resistance is evaluated according to ASTM C1579, which uses a restrained panel with a central stress riser and reports crack width reduction relative to an unreinforced control. In production batching, Sinta M1819 is added to the aggregate stream before water or to the loaded truck drum at a mixing speed of 14 rpm to 16 rpm for a minimum of 5 min. Twin-shaft counter-current mixers require a wet mixing phase of at least 90 s after fibre introduction to prevent filament clustering. The main field failure mode is agglomeration in the aggregate transfer belt when fibre bags are emptied too quickly into a dry stream. Pneumatic conveying into silo storage is not recommended because monofilament bundles can bridge at flanged bends. Slump retention is generally unaffected at the stated dosage. A slight increase in entrapped air of 0.5 % to 1.0 % may occur, requiring confirmation of air content under ASTM C231. The fibre does not raise compressive strength. Published data for this specific configuration show plastic shrinkage crack area reductions of 40 % to 80 % under ASTM C1579 conditions, with product-specific results subject to aggregate grading and evaporation rate. The operational boundary is explicit: if evaporation rate exceeds 1.0 kg/m²/h or wind speed exceeds 16 km/h, fibre alone will not suppress cracking, and curing membrane, fog misting, or wet burlap remains mandatory. In self-consolidating concrete with slump flow above 650 mm, fibre may float toward the top 5 mm layer, so formwork vibration should be limited after the first 15 min to avoid re-orientation.

    Application segmentDosage windowControlling standard or test method
    Ready-mixed slab concrete0.6–0.9 kg/m³ASTM C1116/C1116M Type III; ASTM C1579
    Precast architectural panels0.9–1.2 kg/m³EN 14889-2:2006
    Wet-mix shotcrete1.0–2.0 kg/m³EN 14889-2:2006; EN 14488-3
    Flowing calcium sulphate screed0.4–0.8 kg/m³ASTM C1708
    High-strength concrete fire spalling mitigation1.5–3.0 kg/m³EN 1992-1-2; EN 1363-1
    Polymer-modified repair mortar0.5–1.0 kg/m³EN 1504-3; EN 1542

    What Limits Dispersion When Monofilament Fibre Is Added to High-Strength Precast Mixes?

    Because the water-cementitious ratio in high-strength precast mixes is typically 0.32 to 0.38, the free-water film that assists fibre distribution is limited. Sinta M1819 is used in precast concrete cladding panels and non-load-bearing architectural elements to address surface plastic cracking and edge restraint cracking during demoulding. Dispersion is governed less by the fibre cut length and more by the sequence of addition and the shear energy introduced by the pan mixer. A planetary pan mixer with a mixing intensity of 40 m/s to 60 m/s tip speed disperses the monofilament within 60 s to 120 s of wet mixing. The recommended dosage is 0.9 kg/m³ to 1.2 kg/m³ for architectural precast elements with face mix and backing mix layers. The face mix is often self-compacting; fibre is preferentially added to the backing mix only. This avoids visible fibre burnishing on the exposed aggregate or polished surface. Compliance in European markets is established under EN 14889-2:2006, with System 3 attestation of conformity. Commercial virgin polypropylene monofilament fibres of this class typically exhibit tensile strength in the range of 300 MPa to 550 MPa and elastic modulus of 3.5 GPa to 10 GPa, but the absolute values are secondary to dispersion in precast applications. Steam curing at 60 °C to 80 °C does not degrade or shrink the polypropylene matrix because the crystalline melting point of isotactic PP is above 160 °C. Demoulding times are not extended and surface hardness is not reduced. However, if the fibre is added directly to the high-shear mixer without prior dry dispersion, static charge can build on the monofilament surface and create wall adhesion, causing feed throat blockage. This failure mode is observed in plants with relative humidity below 30 %. The limiting operational boundary is therefore an ambient relative humidity of 30 % to 70 % during fibre handling; below that range, anti-static grounding and slower bag discharge are required.

    Shotcrete Batching Sequence Determines Whether the Fibre Functions or Forms Mats

    During wet-mix shotcrete application for temporary ground support, tunnel linings, and rock slope stabilisation, Sinta M1819 is introduced at the concrete batch plant rather than at the nozzle. The fibre addition range is 1.0 kg/m³ to 2.0 kg/m³, with the lower bound applied to dry-process shotcrete and the upper bound to wet-mix sprayed concrete with maximum aggregate size of 8 mm or 10 mm. The primary technical objective is not flexural toughness but control of early-age plastic shrinkage and reduction of rebound under high-velocity impact. Batching sequence determines whether the fibre functions or forms mats. In truck-mixed wet shotcrete, the fibre should be added after 80 % of the batch water and before the final 20 % of superplasticiser. This sequence prevents hydrophobic fibre from competing with cement for wetting and allows the high-range water reducer to disperse the filaments without clumping. Piston pumps with a delivery pressure of 50 bar to 85 bar and air ring pressure of 3 bar to 5 bar are typical. Air line blockage can occur if fibre balls larger than 10 mm reach the spraying nozzle; therefore, a 10 mm screen before the hopper is mandatory. The use of Sinta M1819 in shotcrete requires conformance with EN 14889-2:2006 and project-specific performance verification under EN 14488-3 for flexural energy absorption. However, the 19 mm monofilament is not a structural macrosynthetic fibre. It does not produce the post-crack residual strength of 0.5 MPa to 1.5 MPa typical of steel-fibre-reinforced shotcrete. Published data for this specific configuration is limited; field evidence indicates that when microfibre is overdosed above 2.0 kg/m³, pump strokes become erratic and rebound can increase due to mat formation on the sprayed surface. The operational limitation is therefore a maximum dosage of 2.0 kg/m³ unless a plant-scale pumping trial confirms stable stroke counts and nozzle pressure.

    If a flowing calcium sulphate screed is placed over a heated subfloor at 40 mm to 60 mm thickness, Sinta M1819 is premixed into the dry binder at 0.4 kg/m³ to 0.8 kg/m³ before the addition of gauging water. The function is limited to plastic shrinkage control during the rapid dewatering phase. The circular monofilament cross-section is preferred over fibrillated tape fibre because it does not obstruct the flow ring spread, which is maintained at 240 mm to 280 mm under ASTM C1708. The binder is typically a ternary system of alpha-hemihydrate cement, filler, and polymer dispersion powder. Sinta M1819 is hydrophobic and does not compete for mixing water; the addition rate therefore does not alter the water-to-solids ratio by more than 0.002. Mixing is conducted in a continuous-flow dry mortar mixer with a residence time of 30 s to 60 s. The principal batch-to-batch variance arises when fibre sacks are added after the fine calcium sulphate filler has already coated the mixer blades; static charge can cause monofilament to stick to the blade surface and form a dry film. This is avoided by adding the fibre simultaneously with the coarse filler fraction at the start of the dry mixing cycle. The finished screed shows no significant change in compressive strength at 28 days; published data for polypropylene microfibre in flowing screeds report deviations of less than 5 % from control when dosage remains below 1.0 kg/m³. Above that dosage, flow spread may drop by 10 mm to 20 mm, requiring an increase in superplasticiser of 0.05 % to 0.10 % by binder mass. Sinta M1819 is unsuited to gypsum boards or plasterboard production because the monofilament is not designed for cellulose or mineral wool board cores, and addition there would require revalidation of the fire classification of the board under EN 13501-1.

    Fire Spalling Mitigation in Dense High-Strength Concrete

    The most technically demanding application of Sinta M1819 is the mitigation of explosive spalling in dense high-strength concrete exposed to hydrocarbon or tunnel fire curves. The mechanism is thermally activated. At a furnace temperature of 160 °C to 170 °C, the isotactic polypropylene monofilament melts and leaves a network of capillary channels. These channels allow water vapour pressure to escape from the concrete matrix before the internal pressure exceeds the tensile strength of the heated surface layer. The threshold for this function is not a fixed dosage but depends on concrete permeability, moisture content, heating rate, compressive strength class, and stress state. In concretes with a characteristic cylinder strength above 80 MPa, published peer-reviewed studies report effective addition ranges of 1.5 kg/m³ to 3.0 kg/m³. The corresponding volume fraction is 0.11 % to 0.33 % for a virgin PP fibre with a density of 0.91 g/cm³. The design basis is often EN 1992-1-2, which includes a recommendation for the inclusion of polypropylene microfibres in high-strength concrete subject to fire; the exact dosage must be confirmed by furnace testing of the intended mix. Testing is carried out on unloaded slabs or loaded columns according to EN 1363-1 or project-specific hydrocarbon fire curve protocols. The failure boundary is sharp. If the dosage falls below 1.0 kg/m³, there may be insufficient percolation of melted fibre channels. If the fibre is overdosed above 4.0 kg/m³, the fresh concrete becomes difficult to pump, and the hardened compressive strength may be reduced by 5 % to 10 % due to the increased porosity after fibre burnout. In structural elements with moisture content below 3 % by mass, spalling risk is lower and fibre may not be necessary. In elements with moisture content above 4 % by mass and characteristic strength above 90 MPa, microfibre alone may not prevent spalling; polypropylene fibre works in conjunction with concrete porosity, air voids, and reduced thermal gradient. The limitation is explicit: Sinta M1819 is not a fireproofing material and does not lower the fire resistance rating. It only reduces the probability of explosive spalling. Any fire resistance claim must be certified under the applicable national construction products regulation.

    If Polymer-Modified Repair Mortar Is Required, Latex Type Dictates Fibre Compatibility

    For thick-section repair mortars and precision grouts, the compatibility of Sinta M1819 with the polymer system must be established before production. In repair mortars for hydraulic structures and industrial concrete repair, the fibre is used at 0.5 kg/m³ to 1.0 kg/m³ to control plastic shrinkage in patches and overlays placed above 50 mm thickness. Styrene-butadiene rubber latex and acrylic dispersion systems are compatible with the fibre; the fibre does not adsorb surfactant from the latex and does not alter film formation. The addition sequence in a high-shear colloidal mixer is dry premixing of cement, graded quartz aggregates, and Sinta M1819 for 60 s, followed by addition of water and latex that has been diluted to a polymer-to-cement ratio of 0.10 to 0.20. The fibre reduces plastic settlement cracking but does not improve adhesive bond strength to the substrate. Bond strength must be verified separately by pull-off testing under EN 1542; the presence of the fibre does not substitute for surface profiling, wetting, or bond coat application. In cementitious grouts for machine beds and anchor pockets, the monofilament at 0.4 kg/m³ to 0.6 kg/m³ can reduce early-age edge cracking without affecting flow. However, in epoxy-modified repair mortars the fibre should not be used without trial mixing because the epoxy resin component can coat the monofilament surface and change dispersion behaviour. The same restriction applies to unsaturated polyester polymer concrete, where the polypropylene fibre has no reinforcing function and may float to the surface. Regulatory compliance for repair mortars is assessed under EN 1504-3 for structural and non-structural repair products, with the fibre classified as an additive within the approved formulation. No separate CE mark is necessary for the fibre when used as a minor constituent in a proprietary repair mortar.

    Free Quote

    Competitive Adfil Sinta M1819 - Virgin Polypropylene Monofilament Micro Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Adfil Sinta M1819 is a virgin polypropylene monofilament micro fibre supplied as a non-fibrillating additive for cementitious matrices. The product designation M1819 identifies a monofilament geometry, controlled cut length and packaging configuration within the manufacturer’s range. The fibre is used in concrete, mortar, floor screed, precast concrete and wet-process sprayed concrete to limit plastic shrinkage cracking and plastic settlement. Unlike fibrillated polypropylene tape products, the M1819 filament is extruded as a discrete near-round monofilament and cut to length. The base polymer is virgin polypropylene homopolymer; no reprocessed polyolefin is included in the declared composition.

    For specification purposes, the material is a synthetic microfibre. Under ASTM C1116/C1116M-23 it belongs to Type III synthetic fibre usage. Under EN 14889-2:2006 it is treated as a non-structural fibre for concrete unless project-specific structural validation is performed. Typical addition rates for plastic shrinkage crack control in slab-on-grade placements range from 0.6 kg/m³ to 1.8 kg/m³. Flowable screed mixes may require 1.0 kg/m³ to 2.0 kg/m³, depending on fines content and water-to-binder ratio. These dosage rates influence early-age cracking but do not replace deformed steel reinforcement or macro polymer structural fibres.

    Class-typical physical values for virgin polypropylene monofilament micro fibre include a density near 0.91 g/cm³ per ISO 1183-1:2019, filament diameter between 18 µm and 32 µm, and cut lengths of 6 mm or 12 mm. Tensile strength for monofilament polypropylene of this class is generally between 300 MPa and 500 MPa when tested to ISO 527-2, with elongation at break from 15% to 25%. The elastic modulus lies between 3.5 GPa and 4.5 GPa. Published batch-level data for this specific M1819 configuration is limited; project submittals should rely on the manufacturer’s batch certificate and notified body test records.

    What Distinguishes a Virgin Monofilament Micro Fibre from Fibrillated Polypropylene Tape Fibres?

    The primary difference is geometric and rheological. Fibrillated tape fibre is expanded into a net-like structure with a high specific surface area and irregular cross-section. This structure increases mechanical interlock with coarse aggregate but can promote low-density fibre balls during dry handling, long mixing, or high-shear mixing. The M1819 monofilament is extruded as a discrete round or near-round filament and then cut. The regular cross-section reduces entanglement potential and improves distribution in mixes with low water content and high fines. This geometric distinction does not automatically improve crack control; plastic shrinkage crack performance is dosage-dependent and must be evaluated using ASTM C1579-21 or a comparable restrained-shrinkage method.

    Compared with macro synthetic fibres of 40 mm to 60 mm length and equivalent diameter above 0.3 mm, the M1819 micro fibre does not provide post-crack residual flexural strength under EN 14651. It is not a substitute for steel mesh, steel fibres, or structural macro polymer fibres in load-bearing behaviour. The M1819 is specified only for early-age plastic shrinkage control, settlement crack reduction, and, where separately validated, for reducing explosive spalling in fire-exposed concrete. Relative to glass fibres, virgin polypropylene monofilament has lower modulus and lower tensile strength but is inherently resistant to alkaline pore solution. Glass fibre requires zirconia modification for alkali resistance, whereas polypropylene does not depend on a surface coating for resistance to pH above 12.5. The lower modulus of 3.5 GPa to 4.5 GPa explains why the M1819 is non-structural in hardened concrete.

    Physical Property Envelope and Compliance Markers for the M1819 Class

    The values in the table below represent the typical physical property envelope for virgin polypropylene monofilament micro fibres of the M1819 class. They are not a substitute for the manufacturer’s notified body certificate under EN 14889-2:2006.

    PropertyNominal rangeTest method
    Density0.91 g/cm³ISO 1183-1:2019
    Filament diameter18 µm to 32 µmOptical microscopy
    Cut length6 mm or 12 mmManufacturer’s inspection
    Tensile strength300 MPa to 500 MPaISO 527-2
    Elongation at break15% to 25%ISO 527-2
    Elastic modulus3.5 GPa to 4.5 GPaISO 527-2
    Water absorption<0.1%ASTM D570-98(2021)
    Melting range160 °C to 170 °CISO 11357-3:2018

    Conformity assessment for fibres used in concrete is conducted under EN 14889-2:2006. Essential characteristics include tensile strength, modulus of elasticity, effect on concrete consistence, effect on flexural strength, and release of dangerous substances. For CE marking under the Construction Products Regulation, the product must be accompanied by a declaration of performance. In the United States, the fibre may be specified under ASTM C1116/C1116M-23 Type III; this classification does not by itself establish a design value.

    Because the fibre is a virgin polyolefin and not an electronic component, RoHS is not directly applicable. REACH obligations for articles apply at the EU importer or manufacturer level; verification of Substances of Very High Concern content should be requested from the supplier.

    When the M1819 Monofilament Is Introduced into a Pumped Self-Levelling Screed Mix

    In a forced-action pan mixer of 0.5 m³ to 1.0 m³ capacity, the fibre is most reliably dispersed by adding it after coarse and fine aggregates but before cement and water. Automatic fibre feeders should discharge bulk fibre onto the aggregate weigh belt over 10 s to 15 s to avoid clumping at the transition to the skip. At mixing speeds of 25 rpm to 35 rpm, a dosage of 1.0 kg/m³ is typically distributed within 90 s after fibre introduction. Extended wet mixing beyond 120 s can increase static charge and fibre ball formation; this behaviour is mixer-specific and should be confirmed by plant trial.

    Fibre addition increases plastic viscosity through a three-dimensional network in the mortar fraction. In a self-levelling screed with a flow table spread target of 240 mm to 260 mm per EN 12350-5, the addition of 1.0 kg/m³ may lower flow spread by 10 mm to 25 mm. The correction should be made with polycarboxylate ether high-range water reducer, not by adding uncontrolled water. Increasing the water-to-binder ratio to restore flow reduces compressive strength and increases drying shrinkage. For pumpability, monofilament fibres of 6 mm or 12 mm length generally pass through 50 mm delivery lines, but low-paste mixes may show line pressure increases of 10% to 15%; published data for this specific M1819 configuration is limited. Piston pump stroke should be set to minimise suction-side cavitation when the fibre network raises the viscosity of the mortar fraction.

    In truck-mixer operations, the fibre is added after all water, aggregate and cement are in the drum, then mixed at 12 rpm to 15 rpm for 4 min to 6 min. If fibre clumps are detected at discharge, the addition rate should be slowed or a mechanical pre-disperser should be installed. High-shear paddle mixers above 100 rpm can induce fibre balling more rapidly than truck mixers because of static charge generation; mixing intensity is more influential than total mixing time.

    The fibre does not require pre-drying under ordinary storage conditions, but bags should be kept away from ultraviolet exposure and from temperatures above 80 °C for extended periods. Hydrophobic polypropylene fibre does not absorb mixing water; therefore it does not change the free water content of the mix, but it may alter air-void distribution and total air volume. In air-entrained concrete, the air-entraining admixture dosage may require adjustment after trial batch testing per EN 12350-7. Because the monofilament has low surface energy, it can interact with air-entraining admixtures by providing additional nucleation surfaces or by destabilising the air void shell. A trial batch should measure not only total air content but also the air void spacing factor, commonly referenced at 0.20 mm or below for freeze-thaw resistance under EN 480-11.

    For dry-mix sprayed concrete, the fibre may be metered into the pre-dampened aggregate stream before the gun. Fibre rebound tends to be higher in dry-mix than in wet-mix at the same dosage because of lower paste volume. Nozzle operator adjustments should be based on rebound measurements under project conditions. For wet-mix sprayed concrete, M1819 may be combined with accelerators at the nozzle, but the compatibility of the accelerator with the fibre dispersant must be confirmed using a spray trial and early-age strength development tests per EN 14488-2.

    Thermal Stability Boundaries in Autoclaved and Precast Heat Curing

    Steam curing at 60 °C to 80 °C does not affect the monofilament profile. Autoclave curing at 180 °C to 190 °C exceeds the melting range of virgin polypropylene homopolymer, which is 160 °C to 170 °C per ISO 11357-3:2018. The M1819 is therefore unsuitable for autoclaved aerated concrete production under standard autoclave cycles. In precast plants using accelerated curing at 50 °C to 70 °C, no thermal degradation of the fibre is expected, and the low thermal conductivity of polypropylene does not measurably alter heat transfer at dosages below 2.0 kg/m³.

    In fire-exposed concrete, the melting of polypropylene micro fibres can reduce explosive spalling by creating percolated pore channels. This application requires a separate fire test programme, typically under EN 13381-3 or ISO 834-1, and a fibre dosage commonly between 1.0 kg/m³ and 2.0 kg/m³. The monofilament geometry is used in some high-performance concrete formulations for this purpose, but published data for this exact M1819 designation in fire spalling applications is limited.

    Alkali Resistance and Long-Term Encapsulation in Cementitious Systems

    Polypropylene homopolymer is resistant to hydrolysis and to the alkaline pore solution of portland cement. The pH of normal concrete pore solution ranges from 12.5 to 13.8, depending on cement alkali content and the presence of supplementary cementitious materials. Unlike cellulose or some polyester fibres, polypropylene does not undergo significant alkaline hydrolysis at room temperature. Accelerated screening is sometimes performed by immersion in 1 mol/L sodium hydroxide solution at 20 °C for 28 days; the fibre may also be evaluated under ASTM D7508/D7508M-21 for resistance to hydrolysis and alkali attack. Published data for this specific M1819 designation after extended concrete exposure is limited.

    Ultraviolet stability is relevant only before encapsulation in the cementitious matrix. Bulk fibre stored outdoors in sunlight can embrittle over extended exposure. Bags should be stored below 40 °C and protected from UV radiation. After concrete sets, the fibre is shielded from light and oxygen diffusion is restricted; oxidative degradation is not the governing failure mechanism in concrete.

    The M1819 monofilament is not a substitute for structural crack-width design

    In structural elements, crack width control under service loads is governed by reinforced concrete design codes such as EN 1992-1-1 and ACI 318-19. Polypropylene micro fibre contributes to plastic shrinkage control before the concrete reaches its initial set, but it does not provide the post-cracking tensile capacity needed to control flexural crack widths in hardened structural members. Designers should not reduce conventional reinforcement areas or bar spacing on the basis of M1819 addition. Where a project requires post-crack residual strength, macro polymer fibres tested under EN 14651 or ASTM C1609/C1609M-19 should be evaluated separately.

    In slabs on grade, the fibre may be specified to reduce random plastic shrinkage cracks during the first 8 h after placement. Crack reduction should be verified by ASTM C1579-21 or by site mock-ups under representative wind speed, temperature and relative humidity. For interior slabs with low evaporation rates, plastic shrinkage risk is lower, and the fibre dosage may be reduced; for slabs placed under high evaporation conditions, curing compounds and windbreaks remain primary measures. The fibre does not replace curing.