Liwei Group Co., Ltd

Products

Adfil Syntec 12 - Polypropylene Ultra-fine Monofilament Microfiber

    • Product Name: Adfil Syntec 12 - Polypropylene Ultra-fine Monofilament Microfiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 393941
    Product Name Adfil Syntec 12 - Polypropylene Ultra-fine Monofilament Microfiber
    Material 100% virgin polypropylene
    Fiber Type Ultra-fine monofilament microfiber
    Fiber Length 12 mm
    Fiber Diameter 0.025 mm
    Aspect Ratio 480
    Specific Gravity 0.91
    Density 0.91 g/cm³
    Tensile Strength 600 MPa
    Elastic Modulus 5 GPa
    Melting Point 160-170 °C
    Alkali Resistance Excellent
    Acid Resistance Excellent
    Water Absorption Nil
    Color Natural / white
    Recommended Dosage 0.6-1.8 kg/m³
    Standard Compliance ASTM C1116 Type III; EN 14889-2 Class I

    As an accredited Adfil Syntec 12 - Polypropylene Ultra-fine Monofilament Microfiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Adfil Syntec 12 supplied in 20 kg moisture-resistant paper sacks, palletized and shrink-wrapped for secure handling and storage.
    Container Loading (20′ FCL) 20′ FCL container loaded with Adfil Syntec 12 – Polypropylene Ultra-fine Monofilament Microfiber, palletized, shrink-wrapped, and securely stowed for ocean export.
    Shipping Adfil Syntec 12 is a non-hazardous polypropylene ultra-fine monofilament microfiber, supplied in moisture-resistant bags on pallets. Ship as general cargo in clean, dry, covered conditions, protected from UV, punctures, and moisture. No dangerous goods declarations required. Observe pallet stacking limits and standard manual handling. Keep dry and avoid excessive heat.
    Storage Store Adfil Syntec 12 in a dry, cool, well-ventilated area using original sealed packaging. Keep pallets off the floor, away from direct sunlight, moisture, heat, ignition sources, and strong oxidizers. Avoid crushing or tearing bags. Maintain ambient temperature and follow FIFO stock rotation. Sweep spills promptly to prevent slipping; no special ventilation is normally required. Protect from physical damage.
    Shelf Life Adfil Syntec 12 has a shelf life of 12 months when stored dry in original unopened packaging, away from direct sunlight.
    Application of Adfil Syntec 12 - Polypropylene Ultra-fine Monofilament Microfiber
    During the initial 6 h after screeding of a slab-on-grade placement, plastic shrinkage cracking is controlled by capillary pressure development in the top 20 mm of fresh concrete, not by long-term drying shrinkage. Adfil Syntec 12, a 12 mm ultra-fine monofilament polypropylene microfiber with a specific gravity near 0.91, is charged in ready-mix operations at 0.6 kg/m³ to 1.8 kg/m³ to provide a multidirectional filament network capable of restraining microplastic cracking before the cementitious matrix reaches final set. At a central mix plant, the fibre is introduced into the skip or aggregate conveyor before the cement and aggregate charge enters the drum mixer; mixing is continued for 5 min to 7 min after final water addition at drum rotation rates of 12 rpm to 18 rpm to break interfilament electrostatic clumps without inducing excessive air entrainment. The resulting concrete falls under ASTM C1116/C1116M-10a Type III for synthetic fibre-reinforced concrete, and plastic shrinkage crack reduction is evaluated using ASTM C1579-21 restrained panel testing under an evaporative air-flow channel that simulates a 1.0 kg/m²/h evaporation rate. Slump measured by ASTM C143/C143M-20 is normally limited to a loss of 15 mm or less at the 0.9 kg/m³ midpoint for a 150 mm target slump mix with a water-cement ratio of 0.45 to 0.55; higher fibre additions up to 1.8 kg/m³ are reserved for placements where wind speed exceeds 2.5 m/s or where the ACI 305R-10 evaporation threshold of 1.0 kg/m²/h is expected within the first 4 h. Terminal components include power-troweled industrial floors, exterior hardstands, and freezer slab installations where joint spacing is retained according to the saw-cut schedule and the fibre is not a substitute for structural steel reinforcement.

    Why Does Wet-Mix Shotcrete Rebound Drop at Specific Polypropylene Addition Rates?

    For underground cavern support and slope stabilization, wet-mix sprayed concrete is conveyed as a premixed paste-aggregate stream and accelerated at the nozzle with compressed air; Adfil Syntec 12 is charged at the concrete plant or during transit to avoid segregation in the pump hopper. The 12 mm fibre length is sufficiently short to pass through 50 mm delivery hose and nozzle manifold components without accumulating behind the air ring, provided the fibre count remains below the threshold that creates fibre-fibre mechanical interlocking in the S-valve. Addition rates of 0.9 kg/m³ to 1.5 kg/m³ are used because the three-dimensional monofilament network reduces aggregate rebound during high-velocity impact; this fresh-state cohesion effect is not a mechanism of hardened flexural strengthening and must not be substituted for steel wire or macrofibres where structural ductility is required. Sprayed concrete requirements are defined in EN 14487-1, fibre content in the hardened shell is checked by EN 14488-7, and sampling of fresh shotcrete for consistency follows ASTM C1436/C1436M-17. On piston pumps with 50 mm delivery line, fibre additions beyond 1.5 kg/m³ produce a measurable increase in the yield stress of the fine mortar phase, appearing as manifold pressure rise rather than as hopper segregation; published pressure loss curves for this specific product in wet-mix shotcrete are limited, and plant trials using a 10 m U-loop circuit are required before production. Terminal products include primary and secondary tunnel linings, rock slope stabilization shells, and shaft wall encasements where early re-entry and rebound minimization within the spray cycle dictate the fibre addition rate.

    Self-Leveling Underlayment Rheology and Microfiber Settlement Thresholds

    Where sheet vinyl or LVT flooring is specified, anhydrite- and CSA-modified self-leveling underlayments are dosed with ultra-fine monofilament polypropylene fibres at 0.05 wt% to 0.15 wt% of dry mortar mass, with the lower bound selected for high-flow systems where visible fibre protrusion would impair vinyl sheet or LVT adhesion and the upper bound selected for rapid-drying patch screeds. The fibre is dry-dispersed in a pin mixer or ploughshare mixer with a tip speed of 20 m/s to 30 m/s for 90 s to 120 s; longer mixing at high tip speed can fracture the 12 mm monofilament and generate short fibre fines that raise the yield stress of the slurry without contributing to crack control. Flow characteristics are evaluated with the EN 12706 flow cone method, and the dosage is normally selected so that the 20-minute ring spread is not reduced by more than 5 mm relative to the unmodified control at a target initial spread of 150 mm. The finished screed material is classified under EN 13813:2002 for both compressive strength class and water permeability; the fibre content is not used to modify the bearing strength class of the screed but to reduce surface microcracking and edge curl during the first 24 h of hydration. Terminal products include self-leveling underlayments for sheet vinyl and LVT flooring, heated floor screeds, and rapid repair screeds in hospital and retail environments where restrained perimeter detailing can otherwise produce shrinkage cracks at door openings and thermal expansion joints.

    ApplicationTypical addition rangeKey standard or methodProcess control threshold
    Ready-mix slab-on-grade0.6–1.8 kg/m³ASTM C1116/C1116M-10a Type III; ASTM C1579-21slump loss ≤ 15 mm at 0.9 kg/m³
    Wet-mix shotcrete0.9–1.5 kg/m³EN 14487-1; EN 14488-7; ASTM C1436/C1436M-17fibre addition capped at 1.5 kg/m³ to limit line pressure rise
    Self-leveling underlayment0.05–0.15 wt% dry massEN 13813:2002; EN 1270620-minute flow spread loss ≤ 5 mm
    Architectural precast panels0.6–1.2 kg/m³ASTM C157/C157M-17; ASTM C666/C666M-15pan mixer 4–6 min after water; demolding within 24 h
    Dry-mix repair mortar0.05–0.20 wt% dry massEN 1504-3:2005; EN 1504-10:2017residual moisture < 0.2 %; ribbon speed 20–40 rpm
    Wet-cast utility vault/pipe0.6–1.2 kg/m³ASTM C39/C39M-21; ASTM C497-20; ASTM C76-22anot for dry-cast; discharge screen check every 20 cycles

    Thin-gauge architectural precast concrete panels with exposed aggregate finishes develop edge spalling during demolding when the surface zone has not reached sufficient tensile strength to resist mould suction and demolding stress. In precast mixes with 30 MPa to 50 MPa 28-day compressive strength and 10 mm to 20 mm coarse aggregate, Adfil Syntec 12 is added at 0.6 kg/m³ to 1.2 kg/m³ to restrain brittle microcracks at the perimeter during the first 24 h after casting. The fibre is introduced into a pan mixer with counter-rotating blades after the aggregate and cement have been dry-mixed for 30 s; mixing continues for 4 min to 6 min after water addition to achieve homogeneous distribution without visible fibre bundles on the exposed aggregate face. Dimensional stability of the hardened element is monitored by ASTM C157/C157M-17 length-change bars, and freeze-thaw resistance for exterior cladding is evaluated with ASTM C666/C666M-15 where the panel is exposed to cyclic moisture. The fibre is not intended to replace conventional welded wire reinforcement or lifting inserts; its function is limited to early-age microcracking and handling damage reduction from demolding to erection. Terminal products include architectural spandrel panels, sound barrier walls, and large-format cladding elements where demolding cycles shorter than 18 h create high surface stress at the form return.

    When Dry-Mix Repair Mortars Are Charged in Vertical Ribbon Blenders

    When charging dry-mix repair mortar ingredients into a vertical ribbon blender, fibre agglomeration occurs if the ultra-fine monofilament fibre is loaded before densified silica fume, producing fibre balls larger than 5 mm at the bagging hopper and creating dead zones within the mixer shell. The charge order for a 1,000 kg batch is mineral binders, then 0.05 wt% to 0.20 wt% of the 12 mm ultra-fine monofilament fibre, then coarse aggregate, and finally low-bulk-density fillers; the ribbon speed is held at 20 rpm to 40 rpm for 5 min to 8 min with side choppers engaged to prevent electrostatic clumping. Because polypropylene is hydrophobic, the residual moisture content of the dry mix must remain below 0.2 % to avoid water-bridge agglomeration on the fibre surfaces; storage in sealed 25 kg bags below 80 % relative humidity is specified. The hardened repair mortar is classified under EN 1504-3:2005 as R3 or R4 according to compressive strength and adhesion, and the selection of the product within a repair system follows EN 1504-10:2017; the synthetic microfiber does not replace structural steel reinforcement and is not considered a strengthening component for crack bridging in structural repair design. Terminal products include 25 kg bagged polymer-modified repair mortars for concrete patch repair, formed surfaces, and overhead applications where batch-to-batch consistency of fibre dispersion controls pumpability and surface finish.

    Precast Utility Vault and Pipe Concrete Surface Crack Control in Wet-Cast Applications

    In wet-cast precast production of utility vaults and manhole bases, synthetic microfiber at 0.6 kg/m³ to 1.2 kg/m³ is used primarily to suppress plastic settlement cracking around embedded structural inserts, knockouts, and lifting sockets. The fibre is dispersed in a twin-shaft horizontal mixer at 30 rpm to 40 rpm before placement into oiled steel forms; external form vibrators are operated at a frequency compatible with 10 mm to 20 mm aggregate consolidation to prevent fibre layering and ensure uniform fibre distribution in vertical walls. Compressive strength of the finished concrete is tested by ASTM C39/C39M-21, absorption by ASTM C497-20, and the structural conduit is specified under ASTM C76-22a for reinforced concrete culvert, storm drain, and sewer pipe; the 12 mm synthetic microfiber is not a substitute for the steel cage or steel reinforcement required for load-bearing pipe classes. The use of this fibre is incompatible with dry-cast pipe manufacturing, where very low water-cement ratios and immediate form stripping lack sufficient shear to uniformly disperse hydrophobic monofilaments and can cause fibre ball formation in the discharge gate; published data for this specific product in dry-cast machinery is limited, and site trials should evaluate the discharge hopper screen after each 20 casting cycles. Terminal products include wet-cast utility vaults, manhole bases, and box culverts where restrained shrinkage around blockouts and curved sections is a watertightness concern.

    Free Quote

    Competitive Adfil Syntec 12 - Polypropylene Ultra-fine Monofilament Microfiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Adfil Syntec 12 - Polypropylene Ultra-fine Monofilament Microfiber is a 12 mm cut-length, round-section, isotactic polypropylene monofilament intended for direct addition to concrete, mortar, and wet-process shotcrete. Under EN 14889-2:2006, the product is classified as a Class I polymer microfibre because the nominal diameter remains below 0.30 mm; under ASTM C1116/C1116M-23, it falls within Type III synthetic fibre. The numeral “12” in the product designation corresponds to the nominal cut length of 12 mm. Manufacturer-published data describe a nominal filament diameter of approximately 18 µm and a polypropylene density of 0.91 g/cm³. From those two values, the calculated filament count is greater than 3 × 10⁸ filaments per kg at full cut-length retention. The material is supplied as individual monofilaments rather than fibrillated tape or macro-synthetic bundle construction. That geometric distinction defines the product’s operational boundary: it is specified for control of plastic shrinkage and plastic settlement cracking, not as a replacement for primary steel reinforcement or as a source of post-crack flexural toughness under EN 14651:2005+A1:2007.

    The hydrophobic character of polypropylene means that storage-related moisture regain is below 0.1% by mass at 23 °C and 50% relative humidity; pre-drying is not required before batching into cementitious systems. Bags should be protected from direct ultraviolet exposure if stored outdoors for periods exceeding 12 months, not because of immediate fibre degradation in concrete, but because packaging integrity and atmospheric oxidation of the fibre surface may drift beyond manufacturer-recommended limits.

    What quality-release specification values are published for Adfil Syntec 12?

    Table 1 lists representative manufacturer-published values. These values are control points for incoming inspection; project specifications should require conformance to EN 14889-2:2006 and, where applicable, ASTM C1116/C1116M-23. Fibre length distribution and diameter are lot-dependent and should be verified by optical microscopy or laser diffraction on samples drawn from the batching plant.

    ParameterPublished valueReference method / standard
    Base polymer100% virgin isotactic polypropyleneSupplier polymer declaration; REACH 1907/2006
    Fibre geometryCircular monofilament, nominal diameter 18 µm, cut length 12 mm, aspect ratio 667Optical microscopy; EN 14889-2:2006
    Density0.91 g/cm³ISO 1183-1:2019
    Melt temperature162 °CISO 3146
    Tensile strength550 MPaASTM D2256 / ISO 2062
    Tensile modulus3.5 GPaASTM D2256 / ISO 2062
    Elongation at break20–30%ASTM D2256 / ISO 2062
    Water absorption<0.1% after 24 h immersion at 23 °CASTM D570-22
    Alkali resistanceTensile strength retention >95% after 28 d in saturated calcium hydroxide solution at 20 °CEN 14889-2:2006
    Filament count>3 × 10⁸ per kgCalculated from density and diameter

    Tensile strength and modulus values for polypropylene microfibres are sensitive to gauge length, strain rate, and conditioning temperature; Table 1 values reflect 20 °C and 65% relative humidity. Published third-party testing of Adfil Syntec 12 under ASTM C1579/C1579M is limited; performance-based acceptance should therefore be demonstrated using the project mix design rather than assumed solely from fibre property tables.

    For concrete slabs, addition rates between 0.6 kg/m³ and 1.0 kg/m³ are common; for precast architectural panels and wet-process shotcrete, dosing is typically 0.9–1.2 kg/m³ and 0.9–1.5 kg/m³, respectively. In truck-mixed concrete, the fibres are introduced into the aggregate weigh hopper or directly into the drum at the batching plant. A minimum of 4 min of mixing at 10–14 rpm is used for uniform dispersion; central-mix operations with twin-shaft compulsory mixers achieve visual dispersion within 60 s. High-shear mixing is not required to separate the monofilaments, and the absence of fibrillation reduces the tendency to form nests in low-water-content concrete. At dosages above 1.8 kg/m³, slump reduction under ASTM C143/C143M is typically less than 10 mm for conventional mixes, but pumpability and finishing should be preconstruction-validated because the increased filament surface area increases paste interaction.

    The crack-control mechanism operates during the plastic state. When surface evaporation exceeds bleeding, capillary menisci create tensile stress in the pore water; the 12 mm monofilament bridges developing microcracks until the matrix develops sufficient tensile strain capacity. This function is evaluated by plastic shrinkage methods such as ASTM C1579/C1579M, where ultra-fine monofilament polypropylene fibres at 0.9 kg/m³ have shown crack-width reductions of 60–80% in independent studies of comparable products. Published test reports specific to Adfil Syntec 12 under ASTM C1579/C1579M are limited, so performance qualification using the project concrete is required before use in slabs with evaporation rates above 0.5 kg/m²/h, as defined in ACI 305R-20.

    When polypropylene ultra-fine monofilament is substituted for fibrillated tape or macro-synthetic fibres

    Substitution decisions depend on whether the specification requires plastic shrinkage control or post-crack residual strength. Fibrillated tape polypropylene microfibres open into branched networks under mixing shear and are typically supplied at irregular denier; a round 18 µm monofilament yields a more predictable cross-sectional area and filament count. The calculated cross-sectional area is approximately 2.5 × 10⁻¹⁰ m². This geometry increases the number of individual crack-bridging elements per kilogram and reduces the probability of fibre balling in mixes with water-to-cement ratios below 0.40. However, the round monofilament does not increase hardened flexural toughness. Macro-synthetic fibres with diameters above 0.30 mm and lengths above 30 mm are designed to provide residual flexural strength under EN 14651:2005+A1:2007 or ASTM C1399/C1399M; Adfil Syntec 12 must not be dosed to meet those performance classes.

    Fibre classGeometry and typical dosagePrimary technical roleOperational difference / boundary
    Adfil Syntec 12 ultra-fine monofilamentCircular monofilament, nominal diameter 18 µm, length 12 mm, dosage 0.6–1.8 kg/m³Plastic shrinkage and settlement crack controlNo structural residual strength; not for EN 14651 design classes
    Fibrillated PP microfibreTape-derived branched geometry, typical equivalent diameter 20–40 µm, length 6–19 mmPlastic shrinkage crack controlMay require higher dose for equivalent plastic crack reduction; fibril branches can affect surface finish
    Macro-synthetic fibreEmbossed or crimped monofilament, diameter 0.30–1.00 mm, length 30–65 mm, dosage often 3.0–9.0 kg/m³Post-crack toughness and hardened crack-width controlWorkability loss and finishability risk increase with dosage; requires structural compatibility verification
    Steel fibreCold-drawn hooked-end, density 7.85 g/cm³, length 35–60 mmStructural crack bridging and post-crack flexural capacityCorrosion possible at exposed cracks; mixing equipment wear; conductive
    Polyester microfibreHydrophobic, typical diameter 7–15 µm, tensile modulus lower than polypropylenePlastic shrinkage control in non-structural elementsAlkali resistance in cement paste may be lower than polypropylene under prolonged exposure

    Because the density of polypropylene is 0.91 g/cm³, the fibres remain suspended in fresh paste without the settling observed with steel fibres in highly flowable concretes. The low-density monofilament also does not create magnetic interference with automated guided vehicle navigation or induction sensors in concrete flooring. Surface finish under steel trowel is generally unaffected at dosages up to 1.2 kg/m³; at higher dosages, fibres may appear at the surface after improper troweling, but that is a placement defect rather than a material incompatibility.

    For high-range water-reducing admixtures based on polycarboxylate ether, no chemical incompatibility with Adfil Syntec 12 is documented. However, simultaneous bulk addition with calcium chloride accelerators or with high-dosage viscosity-modifying admixtures may induce transient fibre clumping because the rapid increase in paste yield stress restricts filament dispersion. In such mixes, the fibre should be added before the accelerator or after the mix has achieved uniform slump. Polypropylene monofilaments are non-conductive and chemically inert in saturated calcium hydroxide; the product does not contain asbestos, silica, or steel, and manufacturer documentation states compliance with RoHS Directive 2011/65/EU and REACH Regulation 1907/2006 Article 33 obligations. The material is not suitable for sustained service above 160 °C because polypropylene softens near its melting point of 162 °C. The product is also not intended for autoclaved aerated concrete processes that operate above 170 °C.

    At batch level, the main field failure mode is not chemical attack but uneven dispersion caused by adding bags too quickly into low-moisture paving mixes. In dry-bagged repair mortars, the fibre is normally blended with aggregates before cement addition; in mobile-mix units, the fibre is dosed by weight into the aggregate boot at 0.6–0.9 kg/m³ for façade repairs. Wet-process shotcrete operations should pass the fibre through the hopper screen to avoid oversized fibre bunches; reported blockages are rare when the nozzle diameter is above 40 mm. For tight spray finishes, a dosage of 0.9 kg/m³ is preferred to balance crack control and surface build-up.