| HS Code | 708767 |
| Productname | MasterFiber 006 |
| Manufacturer | Master Builders Solutions |
| Productcategory | Polypropylene microfiber for concrete |
| Material | 100% virgin polypropylene |
| Fibertype | Monofilament |
| Length | 6 mm |
| Diameter | 0.02 mm |
| Tensilestrength | 350-400 MPa |
| Modulusofelasticity | 3.5 GPa |
| Meltingpoint | 160-170 °C |
| Ignitionpoint | 590 °C |
| Alkaliresistance | Excellent |
| Waterabsorption | Nil |
| Chemicalresistance | Good against acids and alkalis |
| Dosage | 0.6-1.8 kg/m³ |
| Color | Natural/white |
| Packaging | 0.6 kg and 20 kg bags |
| Shelflife | Unlimited in dry conditions |
As an accredited MasterFiber 006 - Polypropylene Microfiber for Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaging: 600 g water-soluble bags, 12 per carton (7.2 kg total) for MasterFiber 006 polypropylene microfiber concrete additive. |
| Container Loading (20′ FCL) | 20′ FCL container loading: MasterFiber 006 - Polypropylene Microfiber for Concrete, bagged product securely stowed and braced for ocean transport. |
| Shipping | MasterFiber 006 ships as a non-hazardous, non-regulated solid in moisture-resistant bags or boxes on pallets. No UN number, hazard class, or packing group required. Use clean, dry vehicles and protect from punctures, moisture, and extreme conditions. Handle with normal care, avoiding dust generation. Suitable for standard truck, rail, or sea freight. |
| Storage | Store MasterFiber 006 in its original, unopened packaging in a dry, clean, cool, well-ventilated area. Protect from moisture, direct sunlight, heat, sparks, and open flames. Keep pallets off the ground, avoid crushing or tearing bags, and rotate stock first-in, first-out. Store away from incompatible materials and excessive temperatures. Use within the manufacturer’s recommended shelf life. |
| Shelf Life | Shelf life is 24 months when stored in original unopened packaging, dry, between 5°C and 35°C, protected from direct sunlight. |
In ready-mix batching operations for interior slab-on-grade and composite metal deck placements, MasterFiber 006 is introduced at the plant into a truck drum after 3 m³ of concrete has batched or through pre-weighed dissolvable bags added to the coarse aggregate charging skip. The dosage range in project specifications is 0.6 kg/m³ to 0.9 kg/m³, which places the application within the microsynthetic fiber guidance of ACI 544.3R-08. Polypropylene has a specific gravity of 0.91 g/cm³ and absorbs no mix water; therefore a slump loss from 150 mm to 120 mm under ASTM C143/C143M at the same free water is attributable to fiber network restructuring rather than water demand. Air content measured by ASTM C231/C231M remains within 0.3% of plain control, and plastic shrinkage crack control is evaluated by ASTM C1579/C1579M, with panel crack area at 24 hours in production trial batches decreasing from 12–18 mm² in plain concrete to 1–4 mm² at the 0.9 kg/m³ dosage. Placement uses a telescopic boom pump and 5 m truss screed, followed by a wooden bull float. Metal deck conditions with profiled steel formwork require slump control at 150 mm ± 20 mm because higher slump causes fiber float toward the top 5 mm of the slab and reduces surface abrasion resistance. Batch-to-batch variance on trucks with worn spiral blades is controlled by an additional 30–60 seconds of high-speed mixing at ≥16 rpm when sand moisture content exceeds 6%; otherwise fiber balls 10–20 mm in diameter have been observed at the discharge chute. Compressive strength at 28 days determined by ASTM C39/C39M remains within 2% of the plain reference mix because microsynthetic fibers do not participate in hydration chemistry. The terminal product range includes residential tower floor slabs, retail podium decks, and mechanical room infill slabs. Curing is initiated after finishing with ASTM C309 Type 1-D polymer membrane at 0.25 mm dry film thickness, or wet burlap when evaporation rate exceeds 0.5 kg/m²/h.
Wet-mix shotcrete containing MasterFiber 006 is batched in a dry-batch plant and charged into a screw-fed rotor pump before a 65 mm delivery line. The addition of 0.9 kg/m³ to 1.5 kg/m³ polypropylene microfibers reduces wet-mix segregation in vertical and overhead repairs because the fiber network increases fresh-state cohesion, but rebound reduction is smaller than the reduction achieved with silica fume at 8% by mass cement. Rebound measured by EN 14488-5 falls from 18–22% in plain control to 14–18% at 1.5 kg/m³, and the nozzleman observes a 0.3–0.5 MPa increase in pump stroke pressure at 45 m horizontal distance, which remains acceptable only if pump hydraulic pressure stays below 80% of rated maximum. Alkali-free aluminum sulfate accelerator is dosed at 6–8% by mass cement at the nozzle; setting time measured by ASTM C403/C403M shifts by less than 20 seconds relative to the same mix without fiber. Early-age compressive strength development at 24 hours in a 25 MPa specified mix remains above 8 MPa when fiber dosage does not exceed 1.5 kg/m³. The application is specified under ACI 506R-16 and EN 14487-1:2022, with final compressive strength typically 25 MPa at 28 days for temporary slope facing. Terminal products include soil-nail head slabs, rockfall ditch lining, canal repair arched sections, and culvert invert protection where thin 75 mm sprayed sections must be placed without wire mesh in one pass.
Producing tunnel segment rings in a fixed-form plant with 12 stationary molds and 6-hour demoulding cycles exposes the outer curved surface to rapid drying after initial steam curing at 55 °C. MasterFiber 006 is added at 0.6–1.0 kg/m³ to the backing batch to reduce plastic-shrinkage cracks on the gasket face and the extrados between form release and demolding. The fiber is classified under EN 14889-2:2006 Class I and does not provide post-crack residual strength; precast segments requiring flexural toughness fR1k ≥ 2.5 MPa under EN 14651:2005+A1:2007 must be reinforced separately with steel or macrosynthetic fibers. Demolding experience on production lines indicates that microfibers below 0.9 kg/m³ do not increase demolding force or mold fouling, but at 1.0 kg/m³ in self-consolidating segment concrete with slump flow of 650 mm, surface fiber blemishes appear on the gasket groove face after 24 hours steam curing. The monofilament polypropylene tensile strength reported by material suppliers ranges from 350–600 MPa, with an elastic modulus of 3.5–5.0 GPa, which is too low to bridge macro-cracks under structural load. The terminal product is a precast tunnel ring with 1.5 m width and 300 mm thickness, installed in TBM-driven metro and utility tunnels. Fire spalling resistance under RWS hydrocarbon curve requires high dosages of polypropylene microfibers of 1.5–3.0 kg/m³; published data for this specific MasterFiber 006 configuration is limited, so fire-resistant segment design requires full-scale furnace validation under RILEM TC 256-SPF guidance.
| Application segment | Governing specification | Verification test | Dosage range | Terminal product |
|---|---|---|---|---|
| Interior slab-on-grade / metal deck | ACI 302.1R-18 | ASTM C1579/C1579M | 0.6–0.9 kg/m³ | Residential tower floor slabs |
| Wet-mix shotcrete | EN 14487-1:2022 | EN 14488-5 | 0.9–1.5 kg/m³ | Soil-nail facing, canal lining |
| Precast tunnel segments | EN 13369:2018 | ASTM C1579/C1579M | 0.6–1.0 kg/m³ | TBM ring segments |
| Architectural precast backing | ACI 533R-11 | ASTM C172/C172M | 0.6 kg/m³ | Facade panels |
| Industrial floor with dry shake | ACI 302.1R-18 | ASTM C779/C779M | 0.6–0.9 kg/m³ | Distribution center floors |
| Secondary containment | ACI 350-20 | ASTM C1581/C1581M | 0.6–0.9 kg/m³ | Containment dikes |
Architectural precast backing mixes exhibit a distinct surface quality constraint when MasterFiber 006 is used only in the non-visible layer of a 100 mm thick ventilated facade panel. The mix design includes 0.34 water-cement ratio, 420 kg/m³ CEM I 52.5N, limestone powder at 120 kg/m³, and a PCE high-range plasticizer at 0.9% by mass cement. The fiber dosage is limited to 0.6 kg/m³ because the exposed face is sandblasted after demolding at 16 hours; higher fiber content causes visible melt-balled polypropylene specks in the gap-graded aggregate surface after 0.5 mm steel-shot blasting. The backing concrete is mixed in a planetary mixer of 2,000 L capacity for 120 seconds after all materials are charged, and fibers are added in 0.6 kg pre-weighed bags during the aggregate blending phase to avoid flocculation. Surface finish acceptance is checked by ASTM C172/C172M sampling at the form and by ACI 533R-11 visual defect criteria for architectural precast. Production bottlenecks occur when limestone filler moisture exceeds 0.5% because the fiber-concentrated paste fraction forms clumps that transfer to the form face under exterior vibration. Terminal products include three-dimensional facade panels, acoustic barrier walls, and polished architectural units where the backing zone does not affect visual acceptance.
Power trowelling of industrial floors with MasterFiber 006 at 0.6–0.9 kg/m³ introduces a timing-dependent surface finish risk not present in plain control slabs. On a 1,200 m² warehouse slab placed by a 3 m laser screed, a ride-on trowel with 900 mm blade diameter begins the first pass 45–60 minutes after discharge at 21 °C and 50% RH. Fibers that have not been covered by mortar paste are dragged into a fuzzy condition if the first pass occurs 15 minutes earlier; this condition cannot be corrected by increasing blade pitch from 10° to 35° in subsequent passes and requires a 2 mm cement slurry grout coat. Dry-shake hardener at 4 kg/m² is broadcast after bleed water shows a visible sheen; polypropylene fiber reduces hardener absorption by 5–10%, so the hardener is pre-hydrated with 0.5 L/m² water. Abrasion resistance after 28 days is specified using ASTM C779/C779M Procedure B, with typical mass loss for 60 minutes below 0.8 g; published data for MasterFiber 006 in this exact dry-shake system is limited, so factory trial panels are required before production. Slab flatness measured by ASTM E1155/E1155M remains at FF50 and FL35 when finishing starts after the correct trowel window; fiber-related surface defects reduce flatness only after premature first-pass operation. Terminal products include distribution center floors, automotive manufacturing aisles, and freezer slabs where wet-cast fiber concrete receives a dry-shake and polishing sequence.
Concrete secondary containment structures for chemical storage present two simultaneous requirements: low surface porosity to prevent permeation and plastic shrinkage crack control at large unformed surface areas. MasterFiber 006 is batched at 0.6–0.9 kg/m³ in a 0.40 w/c mix with 350 kg/m³ cement and 25% fly ash by mass cement. The placement is executed in 2.4 m lifts with 50 mm vibrator spacing not exceeding 300 mm, and the top surface is steel-troweled only after bleeding ceases. Restrained ring testing under ASTM C1581/C1581M shows cracking age increases from 8 days to 21 days at 0.9 kg/m³, but this is not a substitute for waterstop placement or ACI 350-20 crack control joints. The mix design gives 28-day compressive strength of 40 MPa under ASTM C39/C39M, and concrete cover over reinforcing steel in chemical contact is maintained at 50 mm. Terminal products include secondary containment dikes, sump aprons, and fermentation tank bunds where liquid tightness is controlled by both concrete mix proportioning and joint detailing.
Competitive MasterFiber 006 - Polypropylene Microfiber for Concrete prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
MasterFiber 006 is a monofilament polypropylene micro fiber for concrete, specified for the control of plastic shrinkage cracking in fresh and early-age concrete. The product is supplied as a collated fiber package that disperses into individual filaments under normal mechanical mixing. Under ASTM C1116/C1116M-23, MasterFiber 006 belongs to the Type III synthetic micro fiber category. The product is not a structural macro fiber and is not intended to replace welded wire reinforcement, deformed bar reinforcement, or steel fiber for post-crack load capacity. Its primary function is to increase the density of small reinforcing elements in the paste during the bleeding and hardening window when concrete has low tensile strain capacity. The material is suitable for slab-on-grade placements, elevated slabs, precast elements, shotcrete, and other hydraulic cement concrete where reduction of plastic shrinkage crack width is specified.
The filament consists of 100% virgin polypropylene. The specific gravity measured under ASTM D792 is 0.91. The nominal filament length is 6 mm, and the average circular cross-section diameter is 18 µm. The nominal aspect ratio is therefore 333. Based on those dimensions and the specific gravity, the calculated number of filaments per kilogram is approximately 7.2 × 10⁸. At a dosage of 0.9 kg/m³, the spatial density is approximately 6.5 × 10⁸ filaments per cubic meter. The calculated average three-dimensional spacing is on the order of 1.2 mm. The tensile strength of the polypropylene filament under ISO 527-1 is reported in the range 300–400 MPa. The elastic modulus is approximately 3.5 GPa. The material melts at approximately 160 °C and has a water absorption value of 0% under ASTM D570 because polypropylene is hydrophobic. These boundaries control finishing, pumping, fire exposure, and cement compatibility.
| Property | Nominal Value | Test or Reference Method |
|---|---|---|
| Base polymer | 100% virgin polypropylene monofilament | Supplier specification |
| Specific gravity | 0.91 | ASTM D792 |
| Nominal filament length | 6 mm | Supplier QC imaging |
| Nominal filament diameter | 18 µm | Optical microscopy |
| Aspect ratio | 333 | Calculated |
| Tensile strength | 300–400 MPa | ISO 527-1 |
| Elastic modulus | 3.5 GPa | ISO 527-1 |
| Melting point | 160 °C | Differential scanning calorimetry |
| Water absorption | 0% | ASTM D570 |
MasterFiber 006 is differentiated primarily by fiber count per unit mass and crack-control timing. The 6 mm length and 18 µm diameter produce a fiber count that is several orders of magnitude higher than that of a macro synthetic fiber or steel fiber. A kilogram of steel fibers having a length of 60 mm and diameter 0.75 mm contains approximately 4.8 × 10³ fibers. A kilogram of macro synthetic fibers of 60 mm length and 0.5 mm diameter contains approximately 9 × 10⁴ fibers. MasterFiber 006 contains approximately 7.2 × 10⁸ fibers per kilogram. This difference changes the reinforcement mechanism. Micro fibers are distributed within the cement paste and mortar phase where early-age capillary tensile stress initiates cracking. Macro fibers and steel fibers are embedded across the concrete matrix and provide post-crack residual strength after crack opening has occurred. Steel fibers have a specific gravity of 7.85; MasterFiber 006 has a specific gravity of 0.91. Steel fibers can corrode if cracks allow chloride ingress; polypropylene is inert in the alkaline concrete environment. Polypropylene micro fibers do not provide measurable post-crack flexural residual strength under ASTM C1399/C1399M. They are therefore not interchangeable with macro fibers in structural applications.
| Attribute | MasterFiber 006 | Macro synthetic fiber | Steel fiber |
|---|---|---|---|
| Length | 6 mm | 30–60 mm | 30–60 mm |
| Diameter | 18 µm | 0.3–1.0 mm | 0.5–1.0 mm |
| Specific gravity | 0.91 | 0.91–0.95 | 7.85 |
| Calculated fibers per kilogram | 7.2 × 10⁸ | 9 × 10⁴ | 4.8 × 10³ |
| Primary function | Plastic shrinkage crack control | Post-crack residual strength | Post-crack structural capacity |
| Corrosion in cracked concrete | Inert | Inert | Susceptible at exposed cracks |
| Typical dosage | 0.6–1.8 kg/m³ | 3–7 kg/m³ | 15–50 kg/m³ |
Plastic shrinkage crack control is a fiber-spacing problem rather than a fiber-strength problem. The critical parameter is the number of individual filaments available within the paste volume during the first 0–24 h after placement. Concrete with a water-cement ratio between 0.45 and 0.55 can generate sufficient capillary pressure in the menisci between bleeding channels to exceed the early-age tensile strength of the paste when the surface evaporation rate exceeds the bleeding rate. Under ASTM C1579-21, restrained panels without micro fiber can develop visible plastic shrinkage cracks when induced surface evaporation rates exceed 1.0 kg/m²/h. The cracks typically initiate between 1 h and 6 h after finishing, before the concrete reaches final set. MasterFiber 006 does not change the chemical hydration rate; it increases the probability that a growing microcrack encounters a fiber that bridges the opening and reduces crack width. Published restrained shrinkage data for this exact formulation is limited, and project-specific testing under ASTM C1579-21 is recommended when crack-width criteria are written into the specification.
The threshold effect is material. At a dosage of 0.6 kg/m³, the calculated average three-dimensional fiber spacing is approximately 1.3 mm. At 0.9 kg/m³, the spacing is approximately 1.2 mm. At 1.8 kg/m³, the spacing is approximately 0.9 mm. Because the critical flaw size of cement paste under restrained shrinkage is often on the order of 1–3 mm, dosages below 0.6 kg/m³ leave unfibered zones that can coalesce into visible cracks. Above 1.8 kg/m³, further fiber addition reduces the spacing marginally but increases mixing and finishing difficulty, so the incremental benefit is not proportional to the additional fiber mass. This is the property cliff-edge that governs specification of the product: the useful dosage window is narrow, and batching accuracy must be verified. Fiber orientation is not uniformly random in placed concrete. Pumping, vibration, and finishing tend to align fibers horizontally in slab elements, which is favorable for intercepting vertical plastic shrinkage cracks but can reduce the effective crack-plane count in other orientations. The three-dimensional spacing model therefore provides a conservative baseline for crack-intercept probability.
Workability is affected by the increase in internal surface area. At 0.9 kg/m³, the slump measured by ASTM C143/C143M-20 is often within 10 mm of the control mix. At 1.8 kg/m³, the slump commonly decreases by 10–20 mm; high-range water reducer or mix redesign may be required to keep the placement within the specified slump class. Air-entrained concrete should be checked with ASTM C231/C231M-17a because the fiber can stabilize air bubbles in the fresh state. The specified air content must be maintained by adjusting the air-entraining admixture at the plant, not by reducing the fiber dosage below the crack-control threshold.
On twin-shaft compulsory mixers of 2.0–4.5 m³ batch capacity, the product is added to the aggregate stream or to the already-charged aggregate before cement and water. The pre-measured bag is designed to disintegrate under mixer shear. Manufacturer batching guidance recommends extending mixing time by 3–5 minutes after the last complete bag is introduced. In truck mixers, plant addition is preferred because the plant tachometer or batch computer provides a repeatable revolution count. When on-site addition is unavoidable, 90–120 revolutions at 12–14 rpm after bag introduction is the minimum acceptable range before visual inspection for fiber balls. The drum must be charged with aggregate and some water before the bag is added; addition directly into a dry drum or onto a paste-coated mixing blade can generate agglomerates that will not disperse. The primary failure mode observed in production is not fiber failure but non-uniform distribution caused by short mixing time or inadequate shear.
The product does not require pre-wetting and does not absorb mixing water. It can be handled with standard dry-batch conveyors, but the packaging should be protected from rain because saturated paper bags can tear before reaching the mixer. In pumping applications, the 6 mm length is generally compatible with 50 mm pump line reducers, but pump line configuration and concrete workability must be confirmed by a trial placement. The product is not a replacement for proper curing; plastic shrinkage cracks can still occur if surface evaporation is uncontrolled. At dosages of 0.9 kg/m³ or higher, troweling operations may require a short delay to allow bleed water to clear; early finishing can push fibers below the surface or cause surface fuzzing. A final trowel pass with minimal pressure and a low blade angle reduces visible fiber protrusion. Batch records should include fiber bag count, mixer revolutions, and discharge slump. If the fiber ball count exceeds a project visual index, the load should be rejected. Fiber content verification by washout testing can be performed using a 75 µm sieve, but contractor and supplier should agree on the acceptance procedure before placement.
Polypropylene is inert in the alkaline environment of portland cement concrete and does not corrode in chloride-bearing service environments. The product is not a substitute for concrete cover to embedded steel and does not alter the chloride diffusion coefficient of the matrix. For fire-exposed concrete, polypropylene micro fibers can reduce explosive spalling by providing pressure-relief channels after melting, but the required dosage, concrete strength class, aggregate type, and heating rate must be verified by the specified fire test. MasterFiber 006 is not automatically qualified as a fire-protection additive solely on the basis of its polymer composition. Published data for this specific configuration is limited. The product should not be used above 80 °C in continuous service unless elevated-temperature performance is evaluated. At temperatures approaching 160 °C, the filament melts and the crack-controlling geometry is lost.
For specification and compliance, MasterFiber 006 is classified as a Type III synthetic micro fiber under ASTM C1116/C1116M-23. Where European conformity is required, the product can be supplied with a declaration of performance under EN 14889-2:2006; the specific class and use category must be verified on the current CE marking. Production facilities operate under a quality management system certified to ISO 9001:2015. Handling and workplace exposure are addressed in the safety data sheet under REACH regulation EC 1907/2006. The product is not classified as hazardous. It should not be used in contact with strong oxidizing agents or organic solvents that attack polypropylene. Combination with high-range water reducers and air-entraining admixtures must be validated through trial batches because the surface-active chemistry of admixtures can alter the dispersion of hydrophobic fiber surfaces. The dosage must be recorded on the batch ticket as a separate line item to prevent omission or double addition.