MasterFiber 021 - Monofilament Polypropylene Fiber for Concrete

    • Product Name: MasterFiber 021 - Monofilament Polypropylene Fiber for Concrete
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 527413
    Product Name MasterFiber 021
    Material 100% virgin polypropylene
    Fiber Type Monofilament
    Length 19 mm (0.75 in)
    Diameter 0.02 mm (0.0008 in)
    Specific Gravity 0.91
    Tensile Strength 400 MPa (58,000 psi)
    Elastic Modulus 3.5 GPa (500,000 psi)
    Melting Point 160°C (320°F)
    Ignition Point >300°C (>572°F)
    Alkali Resistance Excellent
    Acid Resistance Good
    Water Absorption Nil
    Color Natural
    Recommended Dosage 0.6 kg/m³ (1.0 lb/yd³)
    Packaging 0.6 kg (1.3 lb) bags
    Shelf Life 2 years
    Compliance ASTM C1116 Type III; EN 14889-2 Class I

    As an accredited MasterFiber 021 - Monofilament Polypropylene Fiber for Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing MasterFiber 021 comes in 600 g water-soluble bags, 24 bags per carton (14.4 kg total), suitable for concrete batching.
    Container Loading (20′ FCL) MasterFiber 021 monofilament polypropylene concrete fibers are palletized and loaded into a 20′ FCL container, securely braced for transport.
    Shipping MasterFiber 021 is shipped as a non-hazardous, non-regulated solid in moisture-resistant bags or cartons. It requires no special DOT, IMDG, or IATA classification. Store dry, cool, and away from moisture and UV exposure. Handle with standard dust PPE; avoid inhalation and spreading loose fibers.
    Storage Store indoors in a cool, dry, well-ventilated area away from direct sunlight, heat, and ignition sources. Keep original packaging tightly closed, palletized off the ground, and protected from moisture, dust, and contamination. Avoid excessive temperatures and package damage. Use FIFO stock rotation. Product is stable under normal storage conditions; do not stack beyond safe height.
    Shelf Life Shelf life is 24 months when stored in original, unopened packaging in dry conditions, protected from direct sunlight and moisture.
    Application of MasterFiber 021 - Monofilament Polypropylene Fiber for Concrete

    In ground-supported floor slab construction for logistics buildings, the highest risk occurs between the initial strike-off and the final power-trowel pass when evaporation from the fresh surface exceeds the bleed water supply rate. MasterFiber 021 is added to the load at 0.9 kg/m³, a dosage positioned within Type III synthetic fibre-reinforced concrete under ASTM C1116/C1116M and validated by restrained plastic shrinkage testing under ASTM C1579-21. The applicable compliance envelope for slab placement includes ACI 302.1R-15 and ACI 360R; subgrade moisture and vapor barrier selection follows the floor slab project specification. For production, bulk bags or water-soluble bags of MasterFiber 021 are introduced onto the aggregate weigh batcher before the initial water reaches the charge, then mixed at 12–18 rpm drum rotation for 4–5 minutes after all ingredients are batched. The concrete is discharged at 120–150 mm slump and placed with a ride-on laser screed; subsequent finishing begins only after bleed water has evaporated, and final trowelling is performed with a walk-behind power trowel at blade angle 20–30°. Terminal product types include automated storage/retrieval racking slabs, cross-dock approaches, and cold-storage floors where thermal contraction joints are required. Plant observations show that direct introduction of fibres onto wet aggregate can produce fibre balls at the mix truck discharge gate; therefore batching personnel compare the ready-mix ticket to the incoming MasterFiber batch weight before discharge. MasterFiber 021 does not replace dowel strip load-transfer assemblies or sawcut joint detailing for rack leg aisles; its function is restricted to early-age plastic shrinkage crack control, and it provides no increase in long-term flexural moment capacity under ACI 360R.

    Precast Plant Vibration Setpoints and Edge Rejection Thresholds

    Wet-cast precast elements produced on steel vibration tables require edge and corner integrity because demolding and handling after 8–16 h of accelerated curing generate high tensile stress concentrations at return corners, reveal strips, and knock-out openings. MasterFiber 021 is added at 0.9–1.2 kg/m³ in pan-mixer or twin-shaft counter-current mixer batches; the mixing intensity is set to 95–110 s dry homogenization before water addition, followed by 120–150 s wet mixing. The relevant standards are EN 13369 for common precast concrete products, EN 14889-2 Class I for polymer fibres in concrete, and ASTM C1116/C1116M when the element is supplied into a North American specification. Production data from precast yards show that fibre addition at the higher end of the range can inhibit surface bleeding and increase the appearance of entrapped air along vertical mold faces when vibration frequency is below 45 Hz; therefore vibration tables are run at 50–65 Hz and form fill is limited to 30–45 s per layer. Terminal products include manhole riser sections, cable troughs, retaining wall blocks, and pump station base slabs. For zero-slump dry-cast pipe and paver production, published data for MasterFiber 021 in this specific configuration is limited, and plant trials should precede high-volume adoption because dosages above 1.0 kg/m³ may reduce compactability in short-vibration block machines.

    Wet-mix sprayed concrete placement in tunnel headings starts with a base mix that arrives from the batching plant at 180–220 mm slump and is then accelerated at the nozzle. MasterFiber 021 is dosed at 0.9–1.8 kg/m³; the lower bound is specified for general rock sealing, while the upper bound is used only when crew observations under EN 14487-2 show early surface tearing on thick overhead passes. Execution follows EN 14487-2 for sprayed concrete and ACI 506R-16 for nozzle placement practice; fibre conformity is assessed under EN 14889-2 Class I. The downstream production process uses a high-pressure ram pump or rotor-stator pump connected to a robotic arm, and an alkali-free liquid accelerator is injected through a peristaltic dosing pump at the nozzle body. Field operations require the nozzleman to compare accelerator flow rate against cementitious content because variations in accelerator temperature of 5°C alter pump viscosity and can shift rebound behaviour; early strength development is measured by penetration needle or stud shooting per EN 14488-2. Terminal finished product types include temporary tunnel lining shells, rock slope sealing layers, and canal lining repairs. MasterFiber 021 is not a macrofibre and does not replace steel wire mesh or steel-fibre reinforcement for structural flexural capacity of sprayed concrete linings under rock load.

    What Changes in Fibre-Reinforced One-Coat Render When Wind Load Drives Moisture Loss?

    One-coat render and repair mortar exposed to scaffold wind conditions lose water from the surface at rates that may exceed the mortar bleed rate even before the initial stiffening begins. MasterFiber 021 is incorporated at 0.6–0.9 kg/m³ of fresh mortar; this range is evaluated in dry-mix lines against EN 998-1 classification for rendering mortar and applied under ASTM C926 specification for application of portland cement-based plaster. The production process in a dry-mix plant uses a continuous screw mixer or high-speed paddle mixer to blend the dry components before bagging; the monofilament fiber is added after the fine aggregate and cement are combined to avoid dry segregation, then mixed for 90–120 s. On site, the dry mortar is mixed with the specified water volume and applied by continuous screw pump spray machine at 0.4–0.6 MPa air pressure or trowelled as a scratch and brown coat. Terminal product types include mechanically sprayed one-coat exterior render, hand-applied repair mortar for concrete spalls, and mineral basecoat under synthetic or silicone-based finishes. A known boundary condition is that water addition beyond the bag print range reduces plastic crack control and delays trowel set; conversely, low water addition increases fiber clumping at the spray pump outlet. The fibre does not modify the permeability classification of the render system; the finished facade still relies on the topcoat or hydrophobic admixture for water intrusion resistance.

    For elevated concrete deck toppings placed over steel formwork and ribbed decking, the fresh mix is restrained by composite steel deck bond and exposed to moisture loss simultaneously, producing plastic settlement cracking over bar chairs, headed studs, and cambered beams. MasterFiber 021 is introduced at 0.9 kg/m³ in the ready-mix plant before discharge; the mix is designed with a water-cementitious ratio of 0.38–0.42 and high-range water reducer meeting ASTM C494/C494M Type F to maintain pumpability through boom pumps. The applicable placement documents are ACI 302.1R-15 for concrete floor construction and ASTM C94/C94M for ready-mixed concrete, with fibre-reinforced concrete acceptance under ASTM C1116/C1116M. Placement uses a boom pump to deliver the concrete to a laser screed operating on the deck; finishing starts after surface bleed water is absent and proceeds with ride-on power trowels, with blade float pans on the first pass to minimize surface tearing. Terminal product types include office slab toppings, hospital deck toppings, and apartment podium slabs where flatness number FF 35–50 is common. The fibre is not a replacement for the structural deck reinforcement, headed studs, or negative moment bar detailing; composite slab capacity remains governed by the structural engineer under the applicable cold-formed steel deck specification.

    When Exterior Apron Joint Spacing Is Reduced to Accommodate Thermal Expansion

    Exterior concrete aprons for truck staging and container marshalling yards are placed in long narrow lanes where early-age plastic shrinkage cracking occurs before transverse sawcut windows can be opened. MasterFiber 021 is batched at 0.9 kg/m³, with a higher trial dosage of 1.8 kg/m³ reserved for placements above 30°C or wind speeds above 15 km/h when ACI 305.1-14 evaporation-rate charts exceed 1.0 kg/m²/h. The governing document for the parking lot or handling yard is ACI 330R; ready-mixed concrete is supplied under ASTM C94/C94M, and the fibre-reinforced concrete designation is ASTM C1116/C1116M Type III. Placement proceeds from a central-mix plant to the discharge chute of truck mixers, struck with a laser screed or truss screed, and cured with liquid membrane compound under ASTM C309. Terminal product types include concrete bus pads, truck staging aprons, intermodal container yard lanes, and agricultural equipment hardstands. Joint spacing remains controlled by slab thickness and base friction under ACI 330R; MasterFiber 021 does not permit omission of contraction joints or isolation joint details at columns and pits, and it does not alter the thermal coefficient of concrete.

    Free Quote

    Competitive MasterFiber 021 - Monofilament Polypropylene Fiber for Concrete prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber 021 is a monofilament polypropylene fiber for concrete, supplied as discrete cylindrical filaments with a nominal length of 12 mm, a nominal diameter of 20 μm, a specific gravity of 0.91, and a manufacturer-reported tensile strength of 300 MPa. The product is classified under ASTM C1116/C1116M-23 as a Type III synthetic micro-fiber and under EN 14889-2:2006 as a polymer fiber for non-structural concrete reinforcement. Its primary published function is reduction of plastic shrinkage cracking during the first 24 h after placement, not post-crack structural load transfer. Unlike macro-synthetic fibers with nominal lengths of 38–54 mm, MasterFiber 021 is not intended to provide residual flexural strength under EN 14651 or ASTM C1609/C1609M-19a. This distinction controls specification behavior: the product is selected when the failure mode of interest is early-age surface cracking rather than service-load crack-width control.

    The dosage range is 0.6 kg/m³ to 1.8 kg/m³, with 0.9 kg/m³ routinely specified for interior slabs, composite metal deck, and precast flatwork. At 0.9 kg/m³, the fiber volume fraction is approximately 0.1%. The fibers are hydrophobic, and the manufacturer reports water absorption as nil under standard 24-h immersion; no pre-wetting before batching is required. Dispersion behavior in ready-mix equipment is sequence-dependent. Fibers added to the aggregate stream before cementitious materials distribute more uniformly than fibers added into the first mixing water, especially when the moisture content of fine aggregate is below 5%. Central mixers operating at 12–14 rpm require 5 min after all ingredients are charged to open the fiber bundles; truck mixers at the same dosage may require 7–10 min because the drum does not generate the same shear rate as a pan or twin-shaft mixer. Pan mixers with a rotor tip speed of 2.5 m/s can achieve full fiber opening in 3 min when the fiber is added before the final 20% of batch water.

    Because the product is monofilament rather than fibrillated, the cross-section is circular and continuous. This geometry affects the relationship between fiber count and dosage. At 0.9 kg/m³, the number of discrete filaments per cubic metre is estimated to exceed 10⁸; published data for this specific configuration is limited, but the estimate follows from the nominal diameter and length. The high fiber count is the primary reason for plastic shrinkage control: individual fibers bridge water-filled capillary channels while the cement paste remains plastic and before crack surfaces have formed. After the cement matrix stiffens, the low elastic modulus of polypropylene, typically 3.5 GPa, does not allow meaningful stress transfer across microcracks under sustained shrinkage strain. The elastic modulus of MasterFiber 021 is therefore approximately 1.7% of the modulus of steel fibers. A fiber with a low modulus can still bridge a plastic crack because the crack is filled with fluid and the stress required to pull out the fiber is controlled by surface friction and fiber spacing. Once the matrix sets and crack width is controlled by tensile stress, the fiber unloads. This is the mechanical basis for restricting the product to plastic shrinkage applications.

    What Are the Consequences of Exceeding the Recommended Dosage in Pumped Slab Mixes?

    Above 1.8 kg/m³, the fiber volume fraction remains below the threshold for structural macro-fiber reinforcement, but the fresh-state rheology changes sufficiently to affect placement. Pumped concrete containing excess monofilament fiber may show increased line pressure and localized blockage at reducers with inner diameters below 100 mm. The mechanism is not direct obstruction of the pump valve but accumulation of fibers on the upstream face of a rubber hose coupling or reducer when local velocity falls below 1 m/s. Because the fiber length is 12 mm, the risk is associated with fiber-rich slurry at the first elbow upstream of a taper, not with individual filaments wedging in the piston. The upper dosage boundary is therefore an operational limit rather than a durability limit. Published data for this specific configuration is limited; qualification trials at the project pump length and discharge pressure are required beyond 1.5 kg/m³. For vertical pumping, a mortar-rich interface layer followed by a fleet load at 0.9 kg/m³ reduces the risk of fiber-rich packing at the first elbow.

    The product does not demand a change in cement content or water-to-cement ratio. At 0.9 kg/m³, the dosage changes the cement paste volume by less than 0.1%. However, because fibers add surface area, some mixtures with paste volume below 270 L/m³ may show a measurable reduction in slump of 10–20 mm. The reduction is recoverable by increasing high-range water reducer dosage in small increments, but the fiber should not be compensated by adding water because this would change the water-to-cement ratio and violate the original mix design. In precast production, form release agents should be applied before fiber introduction; fiber filaments that contact the form face before vibration may become aligned parallel to the surface and appear after stripping. Vibration at 50–100 Hz for 5–10 s per insert does not cause fiber segregation at 0.9 kg/m³. At dosages above 1.4 kg/m³, high-frequency vibration may bring fibers to the surface in molds with thin walls below 80 mm.

    Alkaline Resistance and Pore-Solution Compatibility

    The fiber is manufactured from virgin polypropylene, which does not undergo alkaline hydrolysis in concrete pore solution at pH 12.5–13.5. This distinguishes the product from polyester fibers, which can depolymerize under sustained exposure to calcium hydroxide. MasterFiber 021 has no chloride content and does not initiate or sustain corrosion of steel reinforcement; it may be used in concrete containing calcium chloride accelerators at dosages permitted by ACI 318 without modifying the chloride-ion content of the mix. However, it does not provide corrosion inhibition, and the use of the fiber does not allow relaxation of cover depth or curing requirements. The product also does not alter cement hydration kinetics, as measured by isothermal calorimetry at 20 °C; no set retarder or accelerator modification is required at the recommended dosage.

    The product is differentiated from fibrillated polypropylene micro-fibers by its monofilament geometry. A fibrillated fiber is slit and expanded into a branching network; at a given mass, it may display a larger water demand due to the high surface area of the fibril net. MasterFiber 021 presents a discrete cylindrical cross-section that reduces matting in dry storage and allows a higher fiber count per kilogram. Under ASTM C1579/C1579M-21 plastic shrinkage cracking tests, products are compared on the basis of crack area reduction relative to an un-fibered control. Published comparative data for MasterFiber 021 typically place the product in the same crack-control class as fibrillated micro-fibers at lower mass addition; however, exact crack-area reduction values depend on mix design, evaporation rate, and slab aspect ratio, and cannot be generalized across all placements.

    Comparative fiber profile: MasterFiber 021 versus fibrillated micro-fiber and macro-synthetic fiber
    CharacteristicMasterFiber 021Fibrillated PP micro-fiberMacro-synthetic PP fiber
    MaterialMonofilament polypropyleneFibrillated polypropyleneEmbossed macro-synthetic polyolefin
    Nominal length12 mm12–19 mm38–54 mm
    Specific gravity0.910.910.90–0.92
    Tensile strength300 MPa250–350 MPa450–600 MPa
    Typical dosage0.6–1.8 kg/m³0.9–2.0 kg/m³3.0–7.0 kg/m³
    Primary functionPlastic shrinkage controlPlastic shrinkage controlPost-crack toughness
    Post-crack residual strengthNot specified under EN 14651Not specified under EN 14651Specified at CMOD 0.5 mm and 3.5 mm

    Relative to PVA micro-fibers, MasterFiber 021 has no hydroxyl group contribution to cement-matrix adhesion. Its bonding mechanism is primarily mechanical and frictional along the short fiber surface. For this reason, the product is not selected where the specification requires a fiber to increase first-crack strength or to transfer stress across a hardened crack. Compared with macro-synthetic fibers with embossed surfaces and lengths of 38–54 mm, MasterFiber 021 is mixed at a lower mass and does not alter aggregate interlock or saw-cut joint design. In contrast to steel fibers, MasterFiber 021 does not contribute to electromagnetic conductivity, does not present exposed steel at the slab surface, and does not require corrosion protection at cracks. It also does not provide the increase in modulus of rupture that steel-fiber-reinforced concrete achieves under ASTM C78/C78M-21.

    From a compliance standpoint, the product is subject to CE marking under EN 14889-2:2006 for polymer fibers. This requires the manufacturer to declare geometry, tensile strength, elongation at break, and chloride content on the marking label. In jurisdictions following North American practice, ASTM C1116/C1116M-23 Type III covers synthetic micro-fibers for plastic shrinkage crack control but does not set a minimum tensile strength. Therefore, test reports should be read carefully: a Type III classification does not imply structural performance.

    When MasterFiber 021 Replaces Light Gauge Wire Mesh in Interior Slab Specification

    Where project documents permit the substitution of light gauge wire mesh for plastic shrinkage crack control, MasterFiber 021 at 0.9 kg/m³ can be placed without the lifting and positioning operations associated with mesh. The substitution is limited to early-age crack control; it does not replace wire mesh in slabs that require thermal reinforcement, structural continuity, or crack-width control under applied service loads. Saw-cut joint spacing remains governed by ACI 360R-style subgrade drag considerations. Field finishing on slabs dosed at 0.9 kg/m³ is generally comparable to plain concrete, but trowel operators may notice minor surface fuzzing when the dosage exceeds 1.2 kg/m³ and the blade angle is above 25° during the final pass. The surface effect can be managed by wetting the blade or by reducing the final pass speed below 80 rpm.

    Shotcrete crews adding MasterFiber 021 through a wet-mix hopper at 0.9 kg/m³ report no measurable change in air void system or pump strobing. Dry-mix application requires the fiber to be pre-blended into the dry aggregate before the nozzle water is introduced. At vertical wall applications, rebound values may increase by 1–3 percentage points at the upper dosage boundary, although published data for this specific configuration is limited. The fiber length is less than the minimum 10 mm clearance between the nozzle tip and the receiving surface, so nozzle blockages are uncommon; the dominant placement risk is not mechanical obstruction but visual fiber accumulation at the surface if the finish pass is delayed beyond the initial set.

    Batch Verification Is Not a Visual Procedure

    MasterFiber 021 is supplied in pre-weighed bags for direct mixer addition. Because the fiber is white or gray and becomes translucent when wetted, visual estimation of dispersion from a concrete sample is unreliable. The verification procedure should include bag-count or mass-count records at the batching plant, coupled with a mix design review that confirms the dosage in kg/m³ rather than % by weight of cement. Storage should be in a dry area; polypropylene softens at approximately 160 °C, so contact with steam lines or heated aggregate must be avoided. Wet packaging should be rejected because moisture can compact the fibers into mats that do not open during mixing, producing local agglomerates that are visible as fiber balls on the screed line. There is no known chemical incompatibility with portland cement, slag cement, fly ash, silica fume, air-entraining admixtures, or common high-range water reducers when the fiber is dispersed before admixture addition; however, the fiber should not be used as a substitute for any air-entrainment requirement specified under ASTM C260/C260M-10a or EN 934-2.

    Compliance and specification matrix for MasterFiber 021
    DocumentClassificationRelevant requirement
    ASTM C1116/C1116M-23Type III synthetic micro-fiberPlastic-shrinkage crack control; no tensile strength threshold
    EN 14889-2:2006Class II polymer fiberCE marking for non-structural concrete reinforcement
    ASTM C1579/C1579M-21Plastic shrinkage cracking testComparative crack area reduction evaluation
    ASTM C1581/C1581M-18aRestrained ring testAge at cracking and crack-width tendency
    ASTM C1609/C1609M-19aFlexural performanceNot intended for residual strength at L/600 or L/150