| HS Code | 593625 |
| Productname | MasterFiber 050 - Micro Polypropylene Fiber |
| Material | 100% virgin polypropylene |
| Fibertype | Monofilament micro fiber |
| Fiberlength | 12 mm |
| Fiberdiameter | 0.018 mm |
| Aspectratio | 667 |
| Specificgravity | 0.91 |
| Tensilestrength | 350 MPa |
| Elasticmodulus | 3500 MPa |
| Meltingpoint | 160 °C |
| Ignitionpoint | >400 °C |
| Alkaliresistance | Excellent |
| Waterabsorption | Nil |
| Dosagerate | 0.6-1.8 kg/m³ |
| Color | Natural white |
| Form | Monofilament fibers |
| Chemicalresistance | High |
| Uvresistance | Good |
| Thermalconductivity | Low |
| Electricalconductivity | Low |
As an accredited MasterFiber 050 - Micro Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | MasterFiber 050 - Micro Polypropylene Fiber is supplied in 20 kg (44 lb) moisture-resistant paper bags for safe storage and handling. |
| Container Loading (20′ FCL) | MasterFiber 050 micro polypropylene fiber loaded in 20′ FCL: palletized bags, securely stowed, protected from moisture, for ocean shipment. |
| Shipping | MasterFiber 050 – Micro Polypropylene Fiber is non-hazardous and not regulated as dangerous goods under DOT, IMDG, IATA, or ADR. It ships in moisture-resistant bags or sacks, palletized and shrink-wrapped. Store dry in original packaging, avoid punctures, and handle according to the SDS. No special transport classification required. |
| Storage | Always store MasterFiber 050 in original, unopened packaging in a cool, dry, well-ventilated area. Protect from moisture, direct sunlight, heat, and ignition sources. Keep containers sealed to prevent contamination and dust generation. Store away from strong acids, alkalis, and incompatible chemicals. Avoid excessive stacking or physical damage. Follow local regulations and the manufacturer’s safety data sheet. Use good housekeeping practices. |
| Shelf Life | Shelf life is typically 24 months if stored dry in original unopened packaging, away from moisture and direct sunlight. |
In hot-weather ready-mix placement where surface evaporation rises above 0.5 kg/m²/h at concrete temperatures above 30 °C, MasterFiber 050 is metered at 0.9 kg/m³ into the aggregate weigh hopper before water and cementitious materials are introduced. The monofilament is discharged with the coarse aggregate stream across the belt conveyor, allowing the fiber to open and mix with the 4.75–20 mm aggregate fraction before it reaches the truck drum. If direct drum addition is unavoidable at the job site, the fiber is introduced over 4–5 minutes at a mixing speed of 18–20 rpm after 60% of the mixing water has been charged, and mixing continues for a minimum of 70 revolutions after the last bag is added. Field records on 10 m³ truck mixers indicate that dumping whole bags into stagnant water creates monofilament agglomerations that survive 30 minutes of high-speed mixing and appear as surface fuzz on troweled floors. The batching sequence is therefore treated as a critical control point, not a routine handling detail.
Plastic shrinkage crack width is evaluated under ASTM C1579-21 using slab specimens conditioned at 40 °C and 6.0 m/s wind. Published studies for monofilament polypropylene microfibers of this class report crack width reductions of 50–80% compared with plain concrete; product-specific MasterFiber 050 values should be taken from the current technical data sheet and confirmed in a site trial. The fiber is not specified to provide post-crack residual flexural strength under ASTM C1399/C1399M-10, so it does not replace welded wire reinforcement for slab joints spaced beyond 4.5 m. Fresh concrete workability is checked by ASTM C143/C143M-20; slump reductions at 0.9 kg/m³ generally remain below 20 mm when a polycarboxylate-based high-range water reducer is pre-calibrated to the aggregate moisture curve. Dosages above 1.8 kg/m³ are not recommended for pump lines with 3-inch tapered couplings unless a full-scale pumping trial confirms stable line pressure.
| Compliance dimension | Standard designation | Application boundary |
|---|---|---|
| Product conformity | EN 14889-2:2006 | Class II micro polymer fiber for concrete |
| Fiber-reinforced concrete specification | ASTM C1116/C1116M-23 | Type III synthetic fiber-reinforced concrete |
| Plastic shrinkage susceptibility | ASTM C1579-21 | Comparative crack width measurement |
| Restrained shrinkage cracking | ASTM C1581/C1581M-18a | Ring test for early-age cracking potential |
| Fresh air content | ASTM C231/C231M-17a | Pressure method for air-void stability |
| Compressive strength verification | EN 12390-3:2019 | Independent strength series for each mix design |
When MasterFiber 050 is introduced into precast concrete with a water/cement ratio between 0.28 and 0.35, the plastic viscosity of the paste increases enough to alter form-filling behavior in thin ribs and congested cover zones. The fiber is dry-blended with the sand fraction in a planetary counter-current mixer of 1.0 m³ batch volume at pan speed 12–14 rpm and star speed 120–140 rpm for 30 seconds before water and admixture are added. Discharge time after water addition extends by 15–25 seconds relative to an unreinforced mix because the monofilament network delays the state of homogeneous paste coating. Specific power consumption on the mixer drive has been recorded to rise by 5–10% at 1.8 kg/m³; this is an indirect field indicator of dispersion quality when the mixer is instrumented. If the dosage is dumped directly into a high-shear colloidal impeller without pre-blending, fiber balls can form within 20–30 seconds and are not reversed by extended mixing.
Precast tunnel segments, box culverts, manhole risers, and utility duct banks are terminal products where the early-age crack control property is used to protect stripping and handling operations. The product conformity is assessed under EN 14889-2:2006 Class II; compressive strength series are run under EN 12390-3:2019. A maximum dosage of 1.8 kg/m³ is evaluated because higher levels can lower the corrected density of the compacted concrete and increase surface porosity after demolding. With external vibrators operating below 6,000 rpm, compaction time is reduced by 5–10 seconds when the fiber content exceeds 1.2 kg/m³, and the mix should not be maintained at a slump below 80 mm unless a self-consolidating admixture is rebalanced.
Wet-mix shotcrete crews running continuous feed through 50–65 mm hose at nozzle air pressures of 3–5 bar introduce MasterFiber 050 at 1.0–2.0 kg/m³ to reduce early shrinkage fissures in temporary ground support and permanent lining sections. The fiber is added at the batch plant, not at the nozzle, because high-velocity air entrainment at the nozzle cannot reliably distribute monofilaments in the 0.2–0.5 second transit time before impact. Rebound is measured gravimetrically on vertical and overhead panels; published comparisons for polypropylene microfibers report rebound reductions on the order of 10–20% at 1.5 kg/m³, but product-specific data for this configuration is limited and should be confirmed in a field panel. Lines with multiple 90-degree bends or couplings below 50 mm internal diameter have shown blockages when fiber dosage exceeds 2.0 kg/m³; the failure mode is a matted plug at the reducer, not at the nozzle tip.
The terminal use includes rock slope stabilization, tunnel heading advance support, and culvert liners where the concrete is placed against irregular substrates. Shotcrete quality is assessed under EN 14487-1 and ACI 506R-16 guidance; early-age cracking is assessed on site by trained inspectors using comparative panel observation because no standard ASTM test fully captures the micro polypropylene contribution in low-dosage shotcrete. For dry-mix shotcrete, the fiber is pre-blended with the dry cement-sand matrix before passing through the gun; the feed rate must be adjusted by 10–15% because the filament reduces the free flow of the dry material through the hopper gate. The lower bound of 1.0 kg/m³ is retained because below that level the visible reduction in rebound is small and the fiber's principal value is restricted to plastic shrinkage control.
For calcium sulfoaluminate-based self-leveling compounds placed at 6–25 mm thickness over hydronic heating pipes or existing concrete, MasterFiber 050 is incorporated at 0.6–1.2 kg/m³ to bridge the rapid surface crust that forms during forced-air drying. The fiber is dry-dispersed in a high-shear mixer at 500–600 rpm for 2–3 minutes, after the powder has been wetted but before the final flow adjustment. Flow diameter is measured by ASTM C230/C230M-20 after 15 seconds of table drops; reductions of 5–10 mm are observed at 1.2 kg/m³ relative to unfilled reference, and pin-leveling crews compensate by adjusting the water demand within the manufacturer’s prescribed upper limit. Above 1.2 kg/m³, the filaments can protrude through the surface film at 24-hour foot traffic readiness and create observable fuzz after polyurethane topcoat application.
The terminal product is an underlayment that receives vinyl, tile, or epoxy finishes; the absence of surface fiber protrusion is checked by a cloth snag test or equivalent visual standard, not by a standardized ASTM method. Batch-to-batch variance in fiber dispersion is reduced when the micro polypropylene is pre-blended into the dry powder at the production plant rather than added on site. The use of a rotor/stator pump for machine application is possible at 20–40 L/min, but pump hopper screens below 4 mm aperture must be inspected after each 200 L of material to remove any retained agglomerates.
Continuous dry-mix mortar plants often attempt to meter MasterFiber 050 through a loss-in-weight feeder into a twin-screw continuous blender with 30–45 seconds residence time; the question is whether the fiber can be reliably opened in that interval without forming visible clumps. The monofilament is dosed at 0.5–1.2 kg per 1000 kg of dry mix, depending on the target wet mortar dosage and the bulk density of the formulation. When the fiber is metered directly into the main mixer without a pre-opening step, compacted fiber clusters survive the process and appear as hairy inclusions in render basecoats and repair mortars. Production-scale screening with a 0.5 mm square sieve after the blender shows retained fiber clusters below 0.1% only when the fiber is pre-dispersed through a hopper-mounted pin mixer or added simultaneously with the coarsest sand fraction.
The terminal products include machine-applied cement-based renders, bagged patching mortars, and concrete repair materials sold through dry-mix channels. The fiber's conformity to EN 14889-2:2006 Class II is relevant when the finished decorative mortar is covered by a harmonized product standard; otherwise the batch release test focuses on visual dispersion and fresh mortar consistency measured by EN 1015-3:1999. The upper limit is set by the dry mixer's power draw and the risk of fiber bridging in packaging spouts; field audits show that increasing the fiber feed beyond 1.2 kg per 1000 kg can lead to bridging across 40 mm spouts unless mechanical agitation is installed.
In vertical and overhead repair mortars applied by trowel at 15–40 mm lift thickness, MasterFiber 050 is incorporated at 0.9–1.5 kg/m³ to control plastic settlement cracking around embedded reinforcement after the substrate has been prepared to a saturated-surface-dry condition. The repair mortar is mixed with a slow-speed paddle mixer at 400–600 rpm for 3–4 minutes, with the fiber pre-blended into the dry components before the gauging water is introduced. If the fiber is added to a wet mix after the polymer has activated, the viscosity rise prevents monofilament separation and produces visible clumps on the troweled surface. The mortar is applied in layers not exceeding 25 mm per pass; when the total thickness exceeds 40 mm, a structural concrete overlay or anchored mesh is required because the micro fiber does not provide load-bearing crack bridging.
Bridge deck patches, balcony edge repairs, and concrete spall restorations are typical terminal uses. The repair system is selected under EN 1504-3 structural or non-structural class requirements, and the added fiber must not interfere with the specified pull-off strength measured by EN 1542:1999 or the coefficient of thermal expansion of the base repair layer. The upper dosage of 1.5 kg/m³ is evaluated because higher contents can reduce the wet density and increase the entrapped air under hand trowel finishing; air content is checked by EN 1015-7:1998. Published data for MasterFiber 050 in polymer-modified repair mortars is limited, so trial batching under the exact project's curing regime is required before full-scale placement.
Thin architectural precast cladding panels with thickness from 75–120 mm use MasterFiber 050 at 0.9 kg/m³ or lower to control settlement cracking around mix inserts and reveal joints, without creating surface defects after acid etching or bush hammering. The dosage is deliberately held below the ready-mix slab range because exposed polypropylene filaments at the form face are not dissolved by 5–10% hydrochloric acid etching or removed by light sandblasting; visible fibers require a post-demold flame pass. The concrete is placed into vertical battery molds and compacted with external high-frequency vibrators at 3,000–6,000 rpm. Vibration time per station is kept under 45 seconds; prolonged vibration increases the risk of fiber migration toward the form face and creates localized fuzz on returns and chamfers.
Terminal products include architectural facade panels, cornices, column covers, and precast window surrounds. The mix design is validated under ASTM C192/C192M-18 for laboratory trial batches and under ASTM C1579-21 for plastic shrinkage crack width. The fiber does not provide reinforcement for handling stresses after stripping; lifting anchors and demolding stresses are carried by the panel's steel reinforcement or by thickened edge configurations. For architectural surfaces with a polished or acid-etched finish, the acceptable visual defect threshold is typically established on a 600 mm × 600 mm mockup panel under raking light at 3 meters; no universal ASTM procedure governs the surface appearance of micro polypropylene fibers in exposed concrete.
Competitive MasterFiber 050 - Micro Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
MasterFiber 050 - Micro Polypropylene Fiber is a monofilament polypropylene microfiber specified for homogeneous dispersion in concrete, mortar, and screed. The product is classified under EN 14889-2:2006 as a Class II polymer fibre for non-structural crack control and is commonly specified under ASTM C1116/C1116M Type III synthetic fiber-reinforced concrete. Addition rates are generally between 0.6 and 1.2 kg/m³ for slab-on-grade, precast, repair mortar, and sprayed concrete applications. The fibre consists of a polypropylene homopolymer matrix with a specific gravity of approximately 0.91 g/cm³, a melting point between 160 and 170 °C, and water absorption below 0.1 % by mass. In comparison with steel fibres conforming to EN 14889-1, MasterFiber 050 exhibits an elastic modulus of 3.5–5.0 GPa versus approximately 200 GPa; this positions the material as a plastic-shrinkage and fire-spalling control fibre rather than a structural load-transfer reinforcement.
The hydrophobic polypropylene matrix is resistant to chloride ingress, sulfate attack, and the alkaline pore solution of concrete. Pre-drying is not required unless fibres have been stored in bulk silos at relative humidity above 60 %. Sustained exposure above 80 °C can cause dimensional relaxation, although the polymer does not melt until 160–170 °C. MasterFiber 050 should not be used where hardened-state flexural toughness or shear load transfer across structural cracks is the governing design criterion; macro-synthetic fibres conforming to EN 14889-2:2006 Class I or steel fibres conforming to EN 14889-1 are required for those conditions. Polypropylene is nonpolar and does not react with calcium hydroxide, sulfates, or chlorides; however, the polymer is incompatible with strong oxidizing acids and some chlorinated hydrocarbon solvents at elevated temperature.
The product is typically specified by fiber length, equivalent diameter, tensile strength, and melting point because these parameters control dispersibility, plastic crack bridging, and thermal stability. The values below are representative of monofilament polypropylene microfibers of this class and should be confirmed against the current product-specific batch certificate.
| Property | Reported value | Test method |
|---|---|---|
| Fibre type | Monofilament polypropylene | Visual / microscopy |
| Nominal length | 12 mm | Manufacturer method |
| Equivalent diameter | 18 µm | Optical microscopy |
| Specific gravity | 0.91 g/cm³ | ASTM D792 |
| Tensile strength | 300–400 MPa | ASTM D2256 |
| Modulus of elasticity | 3.5–5.0 GPa | ASTM D638 |
| Melting point | 160–170 °C | ISO 3146 |
| Water absorption | <0.1 % by mass | ASTM D570 |
| Typical dosage | 0.6–1.2 kg/m³ | Mix design validation |
Plastic shrinkage cracking occurs when the evaporation rate from the exposed surface exceeds the bleed rate and capillary tension develops in the pore water. The addition of 0.9 kg/m³ MasterFiber 050 increases fiber count to the order of 3.0 × 10^8 fibres per cubic metre for a nominal 12 mm length and 18 µm diameter; this dispersed network intercepts microcracks at openings below 0.3 mm. In restrained slab tests according to ASTM C1579, concrete containing monofilament polypropylene microfibers at 0.9 kg/m³ has been reported to reduce plastic shrinkage crack area by 60–80 % relative to unmodified concrete, dependent on sand morphology, cement fineness, and wind velocity above the slab. The fiber does not prevent bleeding; it redistributes plastic settlement strain and reduces crack coalescence.
Slump response and crack reduction follow a dosage-dependent curve. At 0.6 kg/m³, slump loss in a 0.45 w/c concrete with 320 kg/m³ cement is typically 10–25 mm on a standard slump cone according to EN 12350-2. At 1.2 kg/m³, slump loss can reach 30–50 mm, requiring a polycarboxylate ether superplasticizer conforming to EN 934-2 at 0.4–1.0 % by mass of cement to restore workability without increasing free water demand. In a 1.5 m³ twin-shaft compulsory mixer, fiber balling has been observed when MasterFiber 050 was introduced directly onto wet aggregate after water addition; the corrective sequence is to add the fiber after aggregates and cement but before 70 % of the mix water, followed by a minimum 60-second wet mixing cycle. Extended mixing beyond 120 seconds may increase entrapped air by 1–2 percentage points, and air content should be monitored according to EN 12350-7 when air-entraining admixtures are used.
Because the product is hydrophobic and non-ionic, interaction with polycarboxylate ether superplasticizers is generally minimal, but the large surface area of dispersed microfibers can influence air-void stability. Trial batches with air-entraining admixtures should verify air content and spacing factor under EN 480-11 when freeze-thaw resistance is required. No significant retardation of cement hydration has been recorded with CEM I and CEM II cements at water-cement ratios between 0.35 and 0.50. The fiber addition is not intended to compensate for high-evaporation-rate placement without additional curing; wet curing or evaporation retarders should still be applied when the evaporation rate exceeds 0.5 kg/m²/h.
MasterFiber 050 belongs to the micro-polymer class with an equivalent diameter below 100 µm and a length under 20 mm. Macro-synthetic fibers have diameters above 0.3 mm, lengths of 30–65 mm, and dosages of 2–9 kg/m³, and they are designed to meet post-crack residual strength criteria under ASTM C1609/C1609M or EN 14651. Steel fibers conforming to EN 14889-1 are dosed at 15–60 kg/m³ and provide structural crack-width control, shear transfer, and flexural hardening, but they increase pump wear and reinforcement congestion. AR glass fibers have a modulus of approximately 72 GPa, which is significantly higher than polypropylene, but they require careful matrix design to avoid long-term alkali embrittlement. Cellulose fibers are hydrophilic and absorb water, altering workability more than hydrophobic polypropylene.
| Performance parameter | MasterFiber 050 micro polypropylene | Macro-synthetic fibers | Steel fibers |
|---|---|---|---|
| Primary function | Plastic shrinkage and fire-spalling control | Post-crack toughness | Structural flexural reinforcement |
| Specific gravity | 0.91 g/cm³ | 0.90–0.95 g/cm³ | 7.85 g/cm³ |
| Modulus of elasticity | 3.5–5.0 GPa | 5–10 GPa | 200 GPa |
| Typical dosage | 0.6–1.2 kg/m³ | 2–9 kg/m³ | 15–60 kg/m³ |
| Post-crack residual strength | Negligible | Moderate | High |
| Standards context | EN 14889-2 Class II | EN 14889-2 Class I | EN 14889-1 |
In high-strength concrete exposed to hydrocarbon or RWS fire curves, polypropylene microfibers are used to reduce explosive spalling. When the matrix temperature exceeds 160 °C, the fibers melt and leave percolation channels that allow water vapor pressure to dissipate. Heating rates in an RWS fire can exceed 250 °C/min, producing rapid vapor-pressure buildup that can cause spalling in low-permeability concrete. Typical fire-specific dosages range from 1.0 to 2.0 kg/m³. Published data for this specific configuration is limited for MasterFiber 050, and performance-based fire testing should follow EN 1992-1-2 and relevant EAD or RILEM TC 200-HTC protocols. The fiber does not significantly alter early-age hydration kinetics according to isothermal calorimetry data, and no significant retardation has been recorded with CEM I and CEM II cements at water-cement ratios between 0.35 and 0.50.
For wet-mix sprayed concrete, a monofilament polypropylene fiber dosage of 1.0 kg/m³ is specified when plastic shrinkage control and fire-induced spalling resistance are required, but not when the design demands post-peak flexural toughness according to EN 14487-1 or ASTM C1609/C1609M. In precast elements with thin sections and high surface-to-volume ratio, MasterFiber 050 can be added at 0.6–0.9 kg/m³ to reduce demolding and curing cracks; however, it should not be considered a replacement for secondary steel mesh in load-bearing connections. Rebound measurements with wet-mix sprayed concrete show that polypropylene microfibers have a negligible effect on rebound compared with steel fibers, which may increase rebound by 5–10 percentage points due to denser particle mass. The product can be added in dry-mix sprayed concrete through the aggregate stream, provided that the fiber is dispersed before the nozzle and not collected at the damp aggregate surface.
Quality control for MasterFiber 050 addition requires batch documentation of fiber mass, mixer type, and mixing time. The fiber should be kept away from open flames and chlorinated hydrocarbon solvents; prolonged storage in direct sunlight should be avoided, and the product should remain in intact packaging until use. When stored at relative humidity below 60 %, no pre-drying is required; above 60 % RH, surface moisture can reduce dispersibility and dry blending with aggregates is recommended. The product is not intended for use in concrete with a maximum aggregate size above 32 mm when uniform fiber distribution is required, because segregation can occur in high-slump mixes. In bulk dispensing systems, screw-fed mechanical spreaders are preferred over pneumatic blowing onto wet concrete surfaces because the low fiber density can lead to wind drift and localized over-dosing.