    • Product Name: MasterFiber 141 - Micro Polypropylene Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 633732
    Product Name MasterFiber 141 - Micro Polypropylene Fiber
    Manufacturer Master Builders Solutions
    Material 100% virgin polypropylene
    Fiber Type Monofilament micro synthetic fiber
    Color Natural
    Fiber Length 12 mm
    Fiber Diameter 0.032 mm
    Aspect Ratio 375
    Specific Gravity 0.91 g/cm³
    Tensile Strength 350 MPa
    Elastic Modulus 3.5 GPa
    Melting Point 160-170 °C
    Alkali Resistance Excellent
    Water Absorption Nil
    Chemical Resistance Good
    Uv Resistance Stabilized
    Thermal Conductivity Low
    Electrical Conductivity Low
    Magnetic Properties Non-magnetic
    Corrosion Resistance Non-corrosive
    Dosage Range 0.6-0.9 kg/m³
    Compliance ASTM C1116 Type III

    As an accredited MasterFiber 141 - Micro Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged in 600 g (1.32 lb) water-soluble bags, available in 24-bag cartons.
    Container Loading (20′ FCL) Container Loading (20′ FCL): MasterFiber 141 micro polypropylene fiber, palletized bags, shrink-wrapped, evenly distributed, secured, moisture-protected for ocean transport.
    Shipping MasterFiber 141 – Micro Polypropylene Fiber is non-hazardous and not regulated for transport by DOT, IMDG, IATA, or UN standards. Ship in original sealed bags or boxes on pallets, kept dry and protected from moisture, contamination, and direct sunlight. Store cool, dry, ventilated; use standard PPE and avoid dust.
    Storage Store MasterFiber 141 - Micro Polypropylene Fiber in a cool, dry, well-ventilated warehouse, in original sealed packaging. Keep pallets off the floor and away from moisture, direct sunlight, heat, sparks, and open flames. Avoid dust generation and contamination with oils, chemicals, or strong oxidizers. Maintain ambient temperature, use FIFO stock rotation, and follow SDS/local regulations.
    Shelf Life Shelf life: 12 months from manufacture in original unopened packaging, stored dry at 5–35°C, away from direct sunlight.
    Application of MasterFiber 141 - Micro Polypropylene Fiber

    What Limits Plastic Shrinkage Crack Control in Large-Format Concrete Slabs?

    Plastic shrinkage cracking in large-format slabs is governed by surface evaporation rates exceeding bleeding rates under ACI 305R-20. MasterFiber 141 is introduced during central batch charging at 0.6–0.9 kg/m³, typically as a degradable bag added to the truck mixer after 80% of mixing water is charged. The micro polypropylene product class uses a melt-spun monofilament geometry in the 6–12 mm length and 18–30 µm diameter window; the specific gravity of 0.91 permits distribution without segregation. Verification of plastic shrinkage crack behavior is conducted under ASTM C1579-21 restrained-panel conditions. Published comparative data for micro polypropylene systems with equivalent geometry report total crack width reductions in excess of 40% relative to plain concrete at the same water-cement ratio, though crack-count outcomes beyond 1.8 kg/m³ are not consistently documented for this specific product. Placement with laser screeds and ride-on power trowels requires no adjustment to mix design at fiber doses below 0.9 kg/m³, but air content can shift by 0.5–1.0 percentage points when polycarboxylate-based high-range water reducers are present. Terminal products include warehouse slabs-on-grade, external parking decks, and toll plaza aprons. The primary operational boundary is that micro polypropylene fiber does not replace structural steel, welded wire reinforcement, or macro fibers for post-crack flexural capacity.

    In precast utility structures such as reinforced concrete catch basins, transformer vaults, and junction boxes, dry-cast production with zero-slump concrete at 0.30–0.38 w/c is the primary process window. MasterFiber 141 is pre-blended with the aggregate fraction in a planetary counter-current mixer of 750 L batch capacity before cement slurry is introduced. The addition rate is held between 0.9 kg/m³ and 1.2 kg/m³; higher doses in dry-cast mixes reduce green strength during immediate demolding. Consolidation occurs under high-frequency external vibration at 60–120 Hz, sufficient to dislodge entrapped air without causing fiber balling in mixes with aggregate size below 12.5 mm. The compliance path in North America is ASTM C1116/C1116M-23 Type III synthetic fiber-reinforced concrete, while CE-marked precast sold into the EU requires factory production control under EN 14889-2:2006 for the polymer fiber input. Terminal elements such as grade rings, meter box covers, and catch basin walls are stripped after 6–10 hours of ambient or low-energy steam curing at 45–55°C; the fibers reduce edge chipping and spalling during demolding. The operational boundary is that micro polypropylene fibers do not replace structural steel reinforcement in buried structures subjected to AASHTO HS-20 live load conditions.

    When Polypropylene Microfiber Replaces Steel Mesh in Tunnel Shotcrete

    Wet-mix shotcrete for temporary tunnel linings and rockfall protection places severe demands on pump stability and nozzle flow. MasterFiber 141 at 1.0–1.5 kg/m³ is batched into the transit mixer at the batching plant, before transfer to a screw-type shotcrete machine with 30–40 mm nominal internal diameter delivery line. The fiber addition rate is selected to control early-age plastic shrinkage in sprayed layers of 50–100 mm thickness, not to provide structural flexural toughness. Target rebound under normal mix design conditions is below 12% by mass when accelerator dosage is adjusted from 2% to 3% of cement weight; published comparative data for micro PP versus steel mesh linings show lower rebound losses for fiber mixes, but direct numeric comparisons require site-specific nozzle angle and air flow calibration. Compliance for sprayed concrete performance is referenced to EN 14487-1:2005 and ACI 506R-16; the fiber input to the concrete is covered by EN 14889-2:2006. The finished lining is sprayed in alternating left-to-right bands of 1.2 m width, with each pass compacted using a 6-bar compressed air feed. The terminal product is a temporary shotcrete shell that receives final cast-in-place lining in transit tunnels and rockfall catchment niches. The process boundary is that micro PP fiber does not substitute for macro synthetic or steel fiber when average residual strength values exceeding 0.5 MPa at mid-span deflection are required in permanent shotcrete linings.

    Where overlay thickness remains between 10 mm and 25 mm, thin-section cementitious repair exposes fresh mortar to tensile restraint from the existing substrate. MasterFiber 141 is mixed at 0.6–1.0 kg/m³ in a high-shear counter-current mortar mixer with a total batch time of 180–240 seconds; the fiber is introduced after the polymer-modified binder is fully wetted to avoid dry fiber clumps on the mixing blade. The main plastic cracking risk occurs in the first 6 hours when free water evaporation at the exposed surface creates capillary stress. The repair material is tested under ASTM C928/C928M-20 for packaged dry repair products, and restrained shrinkage is assessed under ASTM C1581/C1581M-18a; micro PP fibers extend time-to-cracking in ring specimens in comparative published studies for repair mortars. Substrate preparation follows ICRI Guideline No. 310.2R-2013; the use of a bonding agent is not waived by the fiber addition. Terminal applications include bridge deck patching, precast element crack repair, and interior floor patching prior to epoxy coating. The operational boundary is that the repaired section must be moist-cured for 7 days to achieve the compressive strength specified by the structural designer; polypropylene microfiber does not accelerate hydration.

    Slab-on-Grade Dosage Windows and Trowel-Finish Timing

    Large industrial floor slabs placed by laser-guided screeds require tight control of finishing operations to maintain superflat floor profiles under ASTM E1155-20. MasterFiber 141 is dosed at 0.6–0.9 kg/m³ in ready-mixed concrete with a target slump of 150 ± 30 mm; the fiber is discharged as a pre-weighed batch from a conveyor-fed hopper into the truck mixer at the plant, followed by 70–90 revolutions at mixing speed. The micro monofilament does not retard initial setting time, but it can alter the bleed-water window on the surface; published guidance for synthetic microfiber slabs recommends delaying the first power-trowel pass by 15–30 minutes in low-humidity placements below 25% RH. The terminal product is a trowel-finished industrial floor with a hard steel-trowel surface covering distribution centers, cleanrooms, and cold-storage aisles. The harmonized fiber specification for EU projects is EN 14889-2:2006; North American projects reference ASTM C1116/C1116M-23 Type III for the concrete mixture. The process boundary is that automated laser-screed vibration frequencies above 400 vibrations/min can cause fiber orientation to follow the compaction pass; published data for surface quality changes at doses above 1.2 kg/m³ in superflat floor tolerances is limited.

    DocumentScopeSlab-on-Grade Application Condition
    ASTM C1116/C1116M-23Fiber-reinforced concrete specificationType III synthetic fiber classification for ready-mix placement
    EN 14889-2:2006Polymer fibres for concreteCE marking required for EU slab projects
    ASTM E1155-20Floor flatness and levelness measurementSuperflat floor acceptance values FF and FL
    ACI 302.1R-15Concrete floor construction guideSubgrade preparation, finishing, and curing methods

    Thermal Spalling Is Mitigated Through Pressure Relief Ports

    Under hydrocarbon fire exposure, high-strength concrete can undergo explosive spalling when water vapor pressure builds inside low-permeability matrices. MasterFiber 141 at 1.5–2.0 kg/m³ is incorporated into cast-in-place tunnel segments and fire-rated slab-on-pile structures to provide pressure relief channels after fiber melting. The polypropylene phase melts in the 160–170°C range and thermal decomposition follows above 350°C; the molten phase creates interconnected micro-permeability paths for vapor escape before the concrete reaches the critical spalling threshold associated with temperatures above 300°C. The mixture is designed to Eurocode 2 Part 1-2 fire provisions and tested under RWS or ISO 834-1 heating curves; published experimental results for monofilament PP systems in high-strength concrete with w/c below 0.35 show reduced spalling depth, but the exact mass loss percentage is a function of aggregate type and moisture content at testing. The terminal product includes fire-resistant tunnel segment linings and high-rise core shear wall sections. The operational boundary is that polypropylene microfiber is not a fireproofing agent; it mitigates spalling but does not reduce the temperature rise through a concrete section. Published data for this specific configuration is limited for cycles beyond 120 minutes of hydrocarbon fire exposure.

    Free Quote

    Competitive MasterFiber 141 - Micro Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber 141 is a micro monofilament polypropylene fiber supplied as secondary reinforcement for concrete, mortar, and shotcrete. The product is composed of collated monofilament bundles of 100% virgin polypropylene that separate into discrete fibers under standard mixing energy. It is classified under ASTM C1116/C1116M as Type III synthetic fiber reinforcement and is not intended to replace primary or structural steel reinforcement. Legacy project specifications may refer to the product under the former designation Fibermesh 141. Manufacturer-published nominal values include a 0.91 specific gravity, a 19 mm fiber length, and a melt temperature of approximately 162 °C. The fiber is non-corrosive, non-magnetic, and alkali-resistant in portland cement environments; published water absorption is reported as negligible. Because the micro-monofilament form provides a higher filament count per unit mass than macro-synthetic products, the product alters early-age crack behavior at a lower mass dosage than structural fibers.

    Compliance checklist and nominal physical data for MasterFiber 141 in cementitious applications
    ParameterReferenced standard or methodReported value or requirement
    Fiber classificationASTM C1116/C1116MType III synthetic fiber-reinforced concrete
    Specific gravityASTM D7920.91
    Nominal fiber lengthManufacturer quality control19 mm
    Melt temperatureASTM D3418162 °C
    Typical dosage for plastic shrinkage controlProject specification0.6–0.9 kg/m³
    Plastic shrinkage cracking testASTM C1579Crack area reduction relative to unreinforced reference
    Slump determinationASTM C143/C143MReported after fiber addition; adjust with approved admixture

    What early-age cracking mechanisms does the product address under restrained conditions?

    Plastic shrinkage cracking occurs when the evaporation rate from a freshly placed concrete surface exceeds the bleeding rate and capillary meniscus tension develops in the pore structure. Restraint from formwork, subgrade friction, reinforcing steel, or differential section depth converts the resulting volume change into tensile strain during the first 6–8 h after placement. In restrained panel testing according to ASTM C1579, concrete containing micro-fibers is compared to a plain reference mixture by measuring crack area after controlled surface drying. Micro polypropylene fibers of the MasterFiber 141 type act by distributed filament bridging and by interrupting microcrack coalescence in the plastic and semi-plastic state. Published product literature reports crack area reduction at dosages around 0.9 kg/m³, but the measured crack area depends on aggregate angularity, cement content, evaporation rate, curing, and slab restraint. This mode of action does not imply post-crack structural capacity at hardened ages.

    The crack reduction measured under ASTM C1579 is a ratio of crack area in the fiber mixture to the crack area in a plain control panel. The test is not intended to predict field crack widths directly, but it provides a standardized ranking of restrained plastic shrinkage behavior. Mixtures that show a large reduction in panel crack area may still crack under sections with high restraint or severe evaporation gradients. Joint layout, early curing, and windbreaks therefore remain part of the placement specification even when the product is used.

    Field experience from full-scale ready-mix production indicates that addition sequence and mixing energy are more important than extended mixing time for dispersion. The fiber is typically added after the initial aggregate and water charge rather than into dry materials to avoid electrostatic aggregation. Central mix plants with twin-shaft compulsory mixers commonly introduce the fiber through an automated dispenser after the first water dose. Truck mixers generally require 60–90 s of agitated mixing at 12–18 rpm after fiber addition for visual dispersion at the standard dosage. Unopened bundles reaching the form are usually traced to insufficient mixing time, very low batch water content, or rapid stiffening in high-early-strength mixtures. These bundles do not contribute to crack bridging and may require immediate screening or finish correction.

    At the commonly specified dosage, the increased fiber surface area may reduce slump measured under ASTM C143/C143M. The actual reduction depends on aggregate grading and paste volume. Adding water solely to restore slump is not recommended because it can increase bleed water demand and reduce compressive strength. Workability can be adjusted with water-reducing or high-range water-reducing admixtures conforming to ASTM C494/C494M Type A or F, provided the mixture remains within the approved project proportions.

    In mixture proportioning, the fiber is added as a low-volume solid fraction and is not normally treated as an aggregate or cementitious material in yield calculations. Air content should be checked during trial batches using ASTM C231/C231M or ASTM C173/C173M, because the monofilament surface can influence the stability of the air-void system in mixtures containing air-entraining admixtures. If air content falls below the specified limit, the air-entraining admixture dose is adjusted within the prequalified mixture design rather than by adding water. Compressive strength acceptance remains based on ASTM C39/C39M cylinders, and the fiber is not considered in the calculated strength gain.

    When the product is specified in slab-on-grade concrete, the dosage is commonly 0.6–0.9 kg/m³ depending on restraint and exposure. The fiber is mixed into the concrete for plastic shrinkage control and is not used to replace welded wire reinforcement or reinforcing bars for joint load transfer. In precast concrete, MasterFiber 141 can be combined with conventional steel reinforcement and does not require modified vibration cycles; because the polymer is non-magnetic, it does not interfere with magnetic mold positioning systems. In dry-mix shotcrete, the fiber is added to the dry blend before gunning, while in wet-mix shotcrete it is introduced through standard fiber feeders. In composite metal deck construction, the product is incorporated into normal-weight concrete at the batch plant and is not relied upon for negative moment resistance; steel reinforcement specified for diaphragm and flexural actions remains mandatory. For topping slabs and repair mortars, the short fiber length is compatible with thin sections, but standard finishing sequences should be followed to avoid exposed filaments and surface fuzzing.

    In high-early-strength concrete, the addition sequence becomes more critical because rapid hydration reduces the time available for fiber transfer and distribution. The product should be added during the first portion of mixing after water contact. Retarded mixtures may require no change to batching sequence. Batch records from central mix plants often show lower fiber waste when an automated fiber dispenser is interlocked with the water flow control rather than operated manually; this prevents dry-fiber addition into static aggregate batches.

    Micro-monofilament, fibrillated, and macro-synthetic fiber systems compared under ASTM C1116 Type III

    All polypropylene fibers used in concrete fall under ASTM C1116/C1116M Type III if they are synthetic, but product form and dosage determine function. A micro monofilament such as MasterFiber 141 is characterized by a small filament cross-section and high fiber count per unit mass. Fibrillated micro-synthetic fibers are produced as slit films that may open into network bundles under mixing and can alter finishability differently. Macro-synthetic fibers have larger dimensions and are typically dosed at higher levels for post-crack residual strength. Representative industry ranges are provided below for comparative purposes; values are not product-specific unless noted.

    Representative industry comparison of synthetic and steel fiber classes used in concrete
    Fiber classTypical dosageNominal lengthPost-crack structural usePrimary test method
    MasterFiber 141 micro monofilament0.6–0.9 kg/m³19 mmNoASTM C1579
    Fibrillated micro-synthetic0.6–0.9 kg/m³19–50 mmNoASTM C1579
    Macro-synthetic polypropylene2.7–7.1 kg/m³40–54 mmYes, after qualificationASTM C1609/C1609M or EN 14651
    Steel fibers12–60 kg/m³30–60 mmYes, after qualificationASTM C1609/C1609M, ASTM A820/A820M

    The dosage distinction is not arbitrary. Microfiber products are optimized for high filament count at low mass addition because plastic shrinkage cracks initiate at the microcrack scale and require distributed interception. Macro-synthetic products are optimized for larger crack openings and post-crack ductility, which requires higher mass dosage and longer embedment length to engage composite action. Published data comparing MasterFiber 141 to specific macro-synthetic products in full-scale structural elements is limited; a Type III micro-fiber should not be substituted for a macro-synthetic or steel fiber system without testing according to the relevant post-crack performance standard.

    Fibrillated micro-synthetic fibers may have an irregular cross-section after mixing, which alters retention of cement paste and can affect surface texture in thin overlays. Monofilament products such as MasterFiber 141 generally remain discrete and smoother in cross-section; however, they may be more visible at the surface after power troweling if finishing is performed too early. The choice between these micro-fiber types is therefore commonly driven by finishability requirements and local concrete practice rather than by a large difference in plastic shrinkage crack reduction potential.

    The lower density of polypropylene, 0.91, compared with steel at 7.85, influences mixing hydrodynamics and fiber settlement; polypropylene fibers do not settle to the bottom in low-viscosity paste and do not produce the same increase in dead load. However, the elastic modulus of polypropylene is much lower than that of steel, so polypropylene microfibers do not provide equivalent crack-width control after hardening. Steel fibers meeting ASTM A820/A820M are classified as Type I in ASTM C1116/C1116M and may require higher paste volume to ensure encasement; MasterFiber 141 is Type III and cannot be assigned the same structural function.

    The operational boundary for MasterFiber 141 is plastic shrinkage crack control and secondary reinforcement in non-structural service conditions. It does not replace primary flexural, shear, or shrinkage reinforcement required by design codes. For bridge decks, structural slabs, or tunnel linings where post-crack residual strength is required, the fiber system must be selected and qualified on the basis of ASTM C1609/C1609M or EN 14651 test results. The standard dosage for plastic shrinkage control is not a fire spalling mitigation strategy; high-temperature spalling resistance may require higher polypropylene fiber dosages and fire-specific validation. As with all synthetic microfibers, curing remains essential: ASTM C309/C309M curing compounds or continuous water curing should be applied because fibers do not reduce the need for moisture retention. Compatibility with air-entraining and water-reducing admixtures should follow the admixture supplier’s sequence and the concrete mixture qualification. The material should not be added to dry cement prior to water in ready-mix operations because this can create fiber balls that are difficult to reverse with normal mixing energy. Storage in a dry area is required for water-soluble or moisture-sensitive packaging, although the polypropylene filament itself has negligible moisture uptake.

    Production-scale failure modes associated with synthetic microfibers include fiber balling in low-slump mixtures, surface fuzzing after hard troweling, and batch-to-batch differences in finishability when fiber lot changes. Fiber balling is typically caused by adding the product to dry aggregates before water or by insufficient mixing in very low-slump concrete. Surface fuzzing appears when finishing is performed too early or when trowel passes draw near-surface fibers upward; it is a finishing process issue rather than a material rejection basis unless the hardened concrete surface does not meet specification. To control batch-to-batch variance, concrete producers may perform a comparative ASTM C1579 panel for each new fiber lot and maintain records of fiber lot number, dosage, mixing time, and slump under ASTM C143/C143M.