Liwei Group Co., Ltd

Products

MasterFiber M 018 - Polypropylene Monofilament Microfiber

    • Product Name: MasterFiber M 018 - Polypropylene Monofilament Microfiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 466992
    Product Name MasterFiber M 018
    Manufacturer Master Builders Solutions
    Material 100% virgin polypropylene
    Fiber Type Monofilament microfiber
    Fiber Length 18 mm
    Specific Gravity 0.91
    Tensile Strength 500 MPa
    Elastic Modulus 3500 MPa
    Melting Point 160 °C
    Ignition Point 590 °C
    Alkali Resistance Excellent
    Acid Resistance Excellent
    Water Absorption Nil
    Corrosion Non-corrosive
    Recommended Dosage 0.6 kg/m³
    Color Natural white
    Packaging 0.6 kg bags
    Shelf Life Indefinite when stored in dry conditions

    As an accredited MasterFiber M 018 - Polypropylene Monofilament Microfiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing MasterFiber M 018 is supplied in 600 g water-soluble bags, with 20 bags per 12 kg carton for convenient dosing.
    Container Loading (20′ FCL) 20′ FCL dry container loaded with palletized MasterFiber M 018 polypropylene monofilament microfiber bags, securely stowed, moisture-protected, and fully documented.
    Shipping MasterFiber M 018 is a non-hazardous polypropylene monofilament microfiber, not regulated for transport by ADR/RID/IMDG/IATA. Ship in original sealed bags or cartons, palletized and shrink-wrapped. Keep dry, away from ignition sources and extreme heat. Handle with standard PPE; avoid dust generation. No special hazard placards required.
    Storage Store MasterFiber M 018 in its original, unopened packaging in a cool, dry, well-ventilated area. Protect from moisture, direct sunlight, excessive heat, and ignition sources. Keep pallets off damp floors; avoid physical damage, punctures, or dust generation. Maintain good housekeeping and first-in, first-out stock rotation. No special temperature control is normally required. Store away from incompatible materials, strong oxidizers, and open flames.
    Shelf Life Typically 24 months from manufacture when stored dry in original unopened packaging; protect from moisture and UV.
    Application of MasterFiber M 018 - Polypropylene Monofilament Microfiber
    MasterFiber M 018 is added to slab-on-grade and industrial floor concrete at a rate of 0.6–0.9 kg/m³. The charge sequence in truck-mixer and central-batch plants places the monofilament polypropylene fiber after coarse aggregate but before the main water injection. This sequence limits fiber balling in the high-shear zone of twin-shaft compulsory mixers operating at 18–24 rpm and batch temperatures between 10°C and 30°C. Wet mixing continues for 60–90 seconds after fiber addition. The hydrophobic fiber has a density of 0.91 g/cm³ and does not absorb mixing water. Dosages above 1.8 kg/m³ are not recommended in pumpable floor mixtures unless a viscosity-modifying admixture is present because free monofilament can raise line pressure on truck-mounted piston pumps. Pumpability must be verified by a site trial using the actual delivery line diameter and boom configuration.Plastic shrinkage cracking potential is evaluated with ASTM C1579-21. The apparatus imposes hot-wind evaporation controlled through a relative humidity gradient and a concrete surface temperature near 36°C for the first 24 hours. A specification threshold commonly requires a crack reduction ratio of at least 40% relative to a plain control mix. Air-entrained concrete remains mandatory where freeze-thaw exposure is defined by ASTM C260/C260M-10a; the microfiber is not an air-void system. Finishing crews should delay trowel passes until bleed water has evaporated and the surface begins to lose sheen. Premature steel troweling forces monofilament into the surface and produces fuzz that is not removed by a single pass. Concrete sampled under ASTM C172/C172M-17 and tested for slump under ASTM C143/C143M-20 should not be rejected solely on the basis of perceived stiffness because the fiber modifies cohesion without affecting water content.

    Does Monofilament Geometry Trigger Rebound Loss in Wet-Mix Shotcrete?

    In wet-mix shotcrete for rock support, shaft lining, and tunnel advance, MasterFiber M 018 is batched at 0.9–1.5 kg/m³ in a pan or twin-shaft mixer at the batching plant. The monofilament has a density of 0.91 g/cm³, which places it within the fine aggregate trajectory during high-velocity spraying. Rebound is governed by aggregate impact angle, paste viscosity, and substrate stiffness, not by fiber geometry alone. The spray nozzle is held at 90° to the substrate with a standoff distance of 0.5–1.0 m, in accordance with EN 14487-1:2022 sprayed concrete specification and consistent with EFNARC guidance. Polypropylene monofilament can become electrostatically attached to delivery hose walls when conveying air is too dry. The mixer discharge should therefore carry enough free moisture to avoid static accumulation, and hoses should be grounded through the pump circuit.Alkali-free liquid accelerators are dosed according to the early strength class and project setting-time requirement defined in EN 14487-1:2022; typical production dosages fall between 4–8% by cement weight. Reducing accelerator dosage solely because of fiber presence is not permitted. The wet-mix line typically uses S-valve piston pumps with 65–125 mm delivery lines. Pre-production spray panels with dimensions of 600 × 600 × 300 mm are prepared for compressive strength and energy absorption tests. Core specimens are extracted under EN 12504-1:2019 and tested under EN 12390-3:2019. Flexural toughness evaluated by EN 14488-3:2006 should not be used to assign structural load capacity to this microfiber; MasterFiber M 018 is not a substitute for steel or polymer macrofibers in residual strength testing under ASTM C1609/C1609M-19a. At the lower dosage of 0.9 kg/m³, the fiber limits plastic shrinkage cracking in sprayed linings but does not materially alter post-crack energy absorption. Published data for this specific configuration is limited. Any specification requiring residual flexural strength must be supported by project-specific sprayed panel testing.

    Precast Element Demoulding and Low-Denier Polypropylene Surface Interactions

    Precast plants producing manholes, box culverts, concrete pipes, and architectural façade panels use MasterFiber M 018 at 0.5–0.9 kg/m³. The monofilament controls early-age shrinkage between form filling and final set. It has no measurable effect on characteristic compressive cylinder strength under EN 12390-3:2019 at 28 days when compared with the same mix without fiber. Dry-cast equipment using high-frequency external vibrators at 3000–6000 rpm may require a shorter vibration cycle because the fiber reduces visible bleed channels that otherwise form laminations at the form face. In wet-cast façade panels, the face layer should be placed as a 10–15 mm fiber-free or low-fiber mixture to eliminate visible monofilament at the architectural surface. Direct troweling of a fiber-containing mix reduces the panel face quality unless a surface retarder or external form release agent is applied in a thin, uniform film.Steam curing at 60–80°C maximum surface temperature is compatible with polypropylene monofilament because the melting point is approximately 160–170°C. Curing chamber ramp rates should not exceed 15°C per hour to avoid thermal shock cracking irrespective of fiber inclusion. For CE-marked precast elements, the plant verifies fiber conformity to EN 14889-2:2006 Class II where requested, and the supplier provides the initial type test and factory production control certificate under Annex ZA. Products intended for contact with drinking water must be evaluated under the applicable member-state regulatory scheme; the polymer fiber is inert, but the overall cementitious matrix and surface coatings govern leachability.
    Standard designationScopeMeasured parameter or classification
    ASTM C1579-21Plastic shrinkage cracking in concreteCrack reduction ratio under forced evaporation
    ASTM C1581/C1581M-18aRestrained shrinkage of mortar and concreteTime to microcrack development
    EN 14487-1:2022Sprayed concrete specificationWet-mix process and placement requirements
    EN 14889-2:2006Polymer fibres for concreteClass II fibre conformity under CE marking
    ASTM C1116/C1116M-10aSynthetic fibre-reinforced concreteType III fibre classification
    Self-leveling underlayment and pump-applied screed formulations require a downward dosage shift to 0.3–0.6 kg/m³. The aggregate skeleton is finer than 2 mm, and higher fiber loading raises plastic viscosity enough to alter flow-table spread. Continuous silo mixers with star feeders should be calibrated by mass rather than by time. A 0.6 kg fiber dose per 1 m³ batch requires pre-dispersion during dry mixing for 120–150 seconds before polymer dispersion powder and water are added. This sequence prevents hydrophobic monofilament flocculation at water-to-cement ratios near 0.35–0.45. Flow-table spread tested under EN 1015-3:1999 should be compared with a fiber-free control. If spread loss exceeds 10 mm, the formulation should be adjusted with a polycarboxylate ether superplasticizer rather than by adding extra water. Published data for this specific configuration is limited; silo discharge tests using the actual star-feeder gate and screw conveyor speed are required.Do not transfer this low dosage into floating screeds with point-load requirements. The fiber is not a structural macrofiber and does not contribute meaningful flexural toughness. In underfloor heating screeds, thermal expansion joints and panel dimensions follow the system supplier’s design rules because microfiber addition does not modify the coefficient of thermal expansion of the hardened cementitious matrix. Calcium sulfate-based screeds present different setting kinetics; trial mixing must follow the binder manufacturer’s specification rather than assuming Portland cement behavior.

    Joints in Rigid Pavement and Whitetopping Respond to Early-Age Shrinkage Strain

    In rigid pavement, whitetopping, and bridge deck overlay mixes, MasterFiber M 018 is charged at 0.9–1.8 kg/m³ in mobile continuous mixers or central batch plants. The main process conflict is saw-cut timing. Polypropylene monofilament suppresses the width of early plastic shrinkage cracks but does not remove the need for contraction joints. Saw cutting is performed as soon as the slab passes the scratch test, typically 4–12 hours after final set depending on slab temperature and cement chemistry. Joint spacing is calculated from ACI 360R-10 or the governing highway agency design manual. The fiber is not a basis to extend joint spacing beyond the design panel dimensions.Restrained drying shrinkage potential is evaluated with ASTM C1581/C1581M-18a, which measures time to microcrack development and strain relaxation. This method is sensitive to ring geometry, moisture loss, and aggregate type. Published data for this specific configuration is limited; project-specific restrained ring tests are recommended for thin whitetopping sections. In 50–100 mm thin overlays, evaporation rates above 0.5 kg/m²/h require fogging, windbreaks, or evaporation retardants irrespective of fiber presence. Surface texture for bridge decks is achieved by tining or grooving before initial set. The monofilament can remain visible at the surface after texturing; a cure and sealant membrane should be applied after texturing to prevent premature drying and to improve surface aesthetics.

    When Trowel-Applied Repair Mortars Are Required to Bridge Plastic Shrinkage Cracks Across Large Substrate Areas

    When trowel-applied repair mortars and thin-bonded overlays are placed on large, dry substrates, MasterFiber M 018 is added at 0.2–0.5 kg/m³ of mortar. The substrate must be preconditioned to a saturated surface dry state. Otherwise, the low water-to-cement ratio repair mortar loses water into the substrate and the monofilament produces a dry, fuzzy finish if troweled after the paste has lost plasticity. Mixing in a paddle mixer at 400–600 rpm for 3–5 minutes is required after all dry components are combined with polymer emulsion and water. The fiber disperses best when the dry mortar, silica sand, cement, and fiber are mixed for 60 seconds before liquid addition. Tensile adhesion is measured by ASTM C1583/C1583M-13 pull-off tests. The fiber does not chemically bond to the substrate and must not replace mechanical surface preparation or the specified bonding agent. Where the repair specification defines a minimum pull-off strength, the repair system is validated with the project substrate and conditioning regime; published data for this specific configuration is limited.Repair materials designed under ASTM C928/C928M-20 are classified by their ability to resist shrinkage and provide a defined level of early and long-term strength. Adding polypropylene monofilament assists only the plastic shrinkage portion of that performance envelope. It does not mitigate drying shrinkage that develops after final set. Curing membranes or moist curing sheets still command the mass loss rate. In coastal or deicing salt environments, chloride ingress remains governed by the permeability of the bonding interface and the cover depth over embedded steel. The fiber is inert but does not act as a corrosion inhibitor.In tilt-up panel construction and site-cast architectural concrete, MasterFiber M 018 is used at 0.5–0.9 kg/m³. The mix is placed directly onto slab casting beds, and the fiber is most effective where the panel thickness is less than 150 mm and the panel area exceeds 40 m². Plastic shrinkage cracking in this geometry initiates between the central lift and the stiff perimeter. The casting bed release agent is applied as a thin, uniform film. Excessive form oil interacts with the hydrophobic fiber surface and can produce dark surface streaks on the exposed face. Panels are frequently cured from the base only; rapid moisture loss from the exposed top face remains a cracking risk. A saturated burlap cover over the top face for the first 12–24 hours is recommended when ambient conditions exceed 30°C and 40% relative humidity. This practice is consistent with ACI 305R-20 hot-weather concreting guidance.Edge lifting and panel flexing during crane handling are structural actions governed by lifting insert capacity and concrete breakout resistance. The microfiber does not alter section capacity in tension. Architectural surface treatments such as acid etching, abrasive blasting, or polishing may expose fibers at the surface; a surface coating or sealer may be required to achieve uniform visual texture. Panel joints and crack-control reinforcements remain part of the design, and the fiber is not used to replace reinforcement in load-bearing panel sections.
    Free Quote

    Competitive MasterFiber M 018 - Polypropylene Monofilament Microfiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    MasterFiber M 018 – Polypropylene Monofilament Microfiber

    MasterFiber M 018 is a polypropylene monofilament microfiber supplied as discrete circular filaments for addition to concrete and mortar. The product is not a fibrillated film fiber, a macro-synthetic structural fiber, or a steel fiber. The numerical suffix 018 is consistent with a nominal filament diameter of 18 µm, while the exact cut length, tensile strength, and dimensional tolerance are stated in the batch certificate of analysis. For specification purposes, the material falls within the Type III synthetic fiber reinforcement category of ASTM C1116/C1116M. Polypropylene fibers in this class typically show a density of 0.90–0.92 g/cm³, a melting range of 160–170 °C, and tensile strength between 300 MPa and 500 MPa. Product-specific values for MasterFiber M 018 should be confirmed from the manufacturer’s technical data sheet before concrete mixture approval.

    Field observations from ready-mix and precast operations indicate that monofilament microfibers of this diameter class are most repeatable when added to the aggregate stream before water and cementitious slurry are introduced. Static charge accumulation in pneumatic conveying lines and high-shear addition after polycarboxylate ether dispersants can produce agglomeration. A precast plant using a 2.0 m³ twin-shaft compulsory mixer at 32 rpm recorded no visible agglomerates larger than 5 mm across 40 consecutive batches when the fiber was dry-mixed with aggregate for 45 seconds before slurry introduction. Reversing the sequence produced intermittent fiber balls up to 25 mm diameter in 8 of 20 batches, requiring additional mixing and, in two cases, rejection of the concrete batch for architectural surface work.

    How Does Monofilament Geometry Affect Dispersion and Plastic Shrinkage Crack Control?

    The controlling mechanism of an 18 µm monofilament in fresh concrete is physical rather than chemical. At a cut length of 6 mm, the fiber count is approximately 7.2 × 10⁸ fibers per kilogram; at a dosage of 0.9 kg/m³, the calculated fiber count is approximately 6.5 × 10⁸ fibers per cubic meter. This count is orders of magnitude higher than the fiber count delivered by typical macro-synthetic or steel fibers. The high number of individual filaments increases the probability that a growing plastic shrinkage crack will intersect a fiber across the bleed-water channel and redistribute capillary tension before the concrete matrix develops sufficient tensile strength to resist crack opening.

    Dispersion quality depends on mixer type, charging sequence, and concrete rheology. In a compulsory pan mixer with a batch volume of 0.75 m³, addition of the microfiber to the coarse aggregate stream produced fewer fiber balls than addition to the cement weigh hopper. Fibers introduced after the high-range water reducer occasionally accumulated at blade tips and formed visible resin agglomerates of 10–30 mm diameter. This failure mode is not a material defect but a batching sequence incompatibility. For ready-mix trucks with 9.1 m³ drum capacity, bag addition during aggregate charging at the plant reduced visible fiber balls to fewer than 1 per m³ of discharged concrete, whereas addition into the cement weigh hopper produced intermittent clumping and required 5–10 minutes of additional mixing to redistribute.

    Plastic shrinkage crack control is commonly evaluated under ASTM C1579-21. Independent studies on polypropylene monofilament microfibers of this class report crack area reductions of 40–80% at dosages between 0.6 kg/m³ and 1.8 kg/m³ relative to unreinforced control panels, provided evaporation rate, finishing operations, and substrate restraint are held constant. The fiber remains inert in the alkaline cement pore solution at pH 12.5–13.5 and does not alter cement hydration kinetics. Workability loss measured by ASTM C143/C143M slump typically ranges from 10% to 20% at 1.8 kg/m³. Compensating with additional water without verifying compressive strength under ASTM C39/C39M is not acceptable.

    Dosage Windows and Batching Sequence Constraints

    For slab-on-grade, composite steel deck, and non-structural overlay applications, the effective dosage window for MasterFiber M 018 is governed by plastic shrinkage exposure rather than structural load capacity. Common addition rates range from 0.6 kg/m³ to 1.8 kg/m³. At 0.9 kg/m³, the fiber volume fraction is approximately 0.10% by volume. At 3.0 kg/m³, the volume fraction approaches 0.33%, at which point pumpability and finishability require rheology verification. The dosage should not be increased beyond the manufacturer’s recommended range solely to compensate for inadequate curing or severe evaporation conditions.

    Batching order is a critical variable. The preferred sequence is to charge approximately 50% of the coarse aggregate, add the fiber, charge the remaining aggregate, and dry-mix for 30–60 seconds before introducing cementitious materials and free water. In truck mixers, the fiber should be added with the aggregate stream at the plant rather than at the jobsite after high-shear mixing has already developed. If pneumatic conveying is used, the line should be grounded and the conveying air velocity kept below 25 m/s to limit static charge accumulation. Condensed moisture on packaging can increase bag-breakage risk in automated dosing systems, but the fiber itself is hydrophobic and absorbs less than 0.1% moisture by mass at 23 °C and 24 h immersion under ASTM D570.

    The use of polypropylene microfibers in tunnel linings and high-temperature concrete has been reported to reduce explosive spalling because the fibers melt and create pressure-relief channels. However, published data for MasterFiber M 018 in this specific fire-exposure configuration is limited. Any project-specific spalling claim must be verified under ISO 834-1 or EN 1992-1-2 fire test protocols using the actual concrete mixture and moisture condition.

    Representative property ranges for polypropylene monofilament microfibers; MasterFiber M 018 batch values must be verified by certificate of analysis.
    PropertyTypical range or nominal valueReference method
    Filament diameter18 µm nominal class designationSupplier optical measurement
    Cut length3–12 mm class range; 6 mm commonASTM D7508/D7508M
    Density0.90–0.92 g/cm³ASTM D792
    Tensile strength300–500 MPaASTM D7508/D7508M fiber test
    Modulus of elasticity3.5–4.5 GPaSupplier tensile test
    Melting point160–170 °CASTM D3418
    Water absorption<0.1% at 23 °C, 24 hASTM D570
    Calculated fiber countApprox. 7.2 × 10⁸ fibers/kg at 6 mm lengthGeometric calculation from diameter and density

    Polypropylene Fiber Chemistry Compared with Fibrillated and Macro-Synthetic Systems

    MasterFiber M 018 is differentiated from fibrillated polypropylene microfibers by its monofilament geometry. Fibrillated fibers are produced as slit and expanded film, yielding a net-like cross-section that requires mechanical working during mixing to break into smaller elements. Monofilament fibers are already individual filaments, so they can provide a more uniform spatial distribution at equivalent dosage, but they are also more sensitive to static charge if added too rapidly into a dry cement-rich environment. The circular cross-section has a lower specific surface area than an opened fibrillated network, which influences the rate of surface wetting and dispersion in low-slump mixtures.

    Macro-synthetic fibers differ in both geometry and performance. Typical macro-synthetic fibers have equivalent diameters of 0.3–0.5 mm and lengths of 30–60 mm, yielding aspect ratios of 60–120. They are designed to engage cracks after the concrete has hardened and to provide residual flexural strength under ASTM C1609/C1609M. Microfibers do not provide equivalent post-crack capacity because their short length and low modulus limit crack bridging after matrix fracture. Steel fibers have a density of 7.85 g/cm³ and a modulus near 210 GPa; they contribute to flexural toughness but are susceptible to surface corrosion, increase mixing equipment wear, and reduce pumpability at higher dosages. Polypropylene monofilament microfiber is chemically inert, non-corrosive, and does not alter the air-void system when added at the prescribed dosage.

    Comparative geometry, dosage, and primary performance metric by fiber type.
    Fiber typeDiameter / lengthTypical dosagePrimary performance metricTest standard
    Monofilament microfiber18 µm / 6 mm class0.6–1.8 kg/m³Plastic shrinkage crack reductionASTM C1579
    Fibrillated microfiber10–40 µm equivalent / 3–19 mm0.6–1.8 kg/m³Plastic shrinkage crack reductionASTM C1579
    Macro-synthetic fiber0.3–0.5 mm / 30–60 mm3.0–9.0 kg/m³Post-crack residual strengthASTM C1609/C1609M
    Steel fiber0.5–1.0 mm / 25–60 mm20–60 kg/m³Structural flexural toughnessASTM C1609/C1609M or EN 14651

    For specification writers, MasterFiber M 018 may be classified under EN 14889-2 as a polymer fiber for use in concrete, provided the manufacturer’s declaration of performance is available. Compliance with REACH Regulation (EC) No 1907/2006 and RoHS Directive 2011/65/EU should be verified through the safety data sheet. Storage should be in original sealed packaging away from temperatures above 50 °C and direct ultraviolet exposure. No pre-drying is required even at relative humidity above 60% because polypropylene is hydrophobic. The fiber does not replace air-entraining admixtures, supplementary cementitious materials, or curing practices, and freeze-thaw resistance should be evaluated under ASTM C666/C666M with the project air-void system intact.

    When Steel Fiber Reinforcement Is Replaced by Polypropylene Microfiber in Overlay Mixes

    Replacement of steel fibers with MasterFiber M 018 is only valid when the design function is control of plastic shrinkage cracking in a non-structural overlay or slab. The fiber count advantage is substantial. At 0.9 kg/m³, the microfiber count exceeds 6 × 10⁸ filaments per cubic meter. A 25 kg/m³ steel fiber dosage with 0.75 mm diameter and 60 mm length produces approximately 1.2 × 10⁵ fibers per cubic meter. That difference explains why microfibers are effective at suppressing early-age microcracks but ineffective in resisting tensile stresses after the matrix has cracked. Where ASTM C1609/C1609M residual strength values or EN 14651 flexural toughness parameters are specified, substitution without redesign is not permissible.

    In a comparable 75 mm thick bonded overlay using a monofilament microfiber of 18 µm diameter, a field trial recorded a slump reduction from 180 mm to 150 mm at 0.9 kg/m³. A polycarboxylate ether high-range water reducer dosage increase of 0.2 L/m³ restored workability without measurable change in 28-day compressive strength under ASTM C39/C39M. Published data for this exact product and overlay configuration is limited, so plant-level verification remains necessary. Surface finishing operations such as troweling can expose or stand up fibers if the concrete is overworked; burnishing should be timed when the surface has sufficient stiffness to embed fibers rather than tear them from the matrix.

    Because the product is hydrophobic and inert, it can be used in precast, ready-mix, and shotcrete systems without altering setting time under ASTM C403/C403M. However, it is not a substitute for structural reinforcement, welded wire mesh, or steel fibers in load-bearing applications requiring post-crack residual strength. Resistance to shrinkage cracking under restrained conditions should be verified using ASTM C1579 or ASTM C1581/C1581M, and project-specific exposure conditions should determine the final dosage. The absence of published performance data for a specific concrete mixture does not transfer into a blanket performance guarantee.