| HS Code | 229930 |
| Productname | MasterFiber M 35 |
| Material | 100% virgin polypropylene |
| Fibertype | Monofilament micro fiber |
| Fiberlength | 12 mm |
| Fiberdiameter | 0.032 mm |
| Aspectratio | 375 |
| Specificgravity | 0.91 |
| Density | 0.91 g/cm³ |
| Tensilestrength | 350 MPa |
| Elasticmodulus | 3.5 GPa |
| Meltingpoint | 160 °C |
| Ignitionpoint | 590 °C |
| Alkaliresistance | Excellent |
| Waterabsorption | Nil |
| Dosage | 0.6 - 1.8 kg/m³ |
| Color | Natural white |
| Standardcompliance | ASTM C1116 Type III, EN 14889-2 Class I |
As an accredited MasterFiber M 35 - Monofilament Micro Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | MasterFiber M 35 packaging: 20 kg (44 lb) moisture-resistant bags, plus 0.9 kg (2 lb) water-soluble bags for concrete mixing. |
| Container Loading (20′ FCL) | MasterFiber M 35 monofilament micro polypropylene fiber, non-hazardous, loaded in a 20-foot FCL container; palletized bags, dry, secure stowage. |
| Shipping | MasterFiber M 35 ships as a non-hazardous, non-flammable solid in sealed bags or cartons on pallets. It is not regulated for transport under DOT, IATA, IMDG, or ADR. Keep packages dry, closed, and avoid dust inhalation. Transport in clean, covered vehicles; no special labeling required. |
| Storage | Store MasterFiber M 35 in its original, unopened packaging in a dry, cool, well-ventilated area. Keep bags off the floor, protected from moisture, direct sunlight, heat, sparks, and flames. Avoid crushing or contamination. Do not store near strong oxidizers. Maintain stable temperatures and use within the manufacturer’s recommended shelf life. Follow local regulations and the Safety Data Sheet. |
| Shelf Life | Shelf life is typically 24 months when stored dry, in original unopened packaging, away from moisture and direct sunlight. |
MasterFiber M 35 conforms to EN 14889-2:2006 Class Ia and ASTM C1116/C1116M-23 Type III as a monofilament micro polypropylene fiber with nominal length 12 mm, nominal diameter 18 µm, and density 0.91 g/cm³. In a 40,000 m² slab-on-grade for an ambient logistics facility, the concrete is batched at 0.9 kg/m³ into a C30/37 mix with 20 mm crushed aggregate, water-to-cement ratio 0.50, and target slump 150 mm per EN 12350-2:2019. The fiber is added to the aggregate fraction before water in a twin-shaft compulsory mixer operating at 18 rpm; this sequence prevents the balling observed when fibers are introduced late into high-slump concrete or when the dosage exceeds 1.8 kg/m³ in short mixing cycles. A laser-guided screed places the concrete and a ride-on power trowel closes the surface. At an evaporation rate above 1.0 kg/m²/h, calculated from the ACI 302.1R-15 nomograph, the surface bleed rate falls below the evaporation rate before finishing. The fibers reduce total crack area under ASTM C1579-21, but do not change the free drying shrinkage value measured by ASTM C157/C157M-17. Saw-cut joints are installed 4 h to 12 h after final set. The finished slab is a jointed logistics floor that still requires dowels, tie bars, and joint sealant.
In wet-mix tunnel shotcrete, MasterFiber M 35 is added at 1.0 kg/m³ to a C28/35 mix with 8 mm maximum aggregate and 0.50 water-to-cement ratio. An alkali-free aluminium sulfate hydroxy accelerator is introduced at the nozzle at 4% to 8% by weight of cement; the rapid set shortens open time and makes fiber dispersion critical. A piston-type concrete pump with 50 mm ID delivery line operates at 12 bar to 18 bar line pressure for a 30 m vertical lift. The fiber length is one-quarter of the line diameter, so the fibers pass the piston transition and hose bends without plugging if they are fully wetted during initial mixing. Rebound samples collected at the nozzle and screened through a 4 mm sieve show that fiber loss increases when the nozzle angle deviates more than 15° from perpendicular to the substrate. The in-place lining is assessed for compressive strength by EN 14488-2:2006 and bond strength by EN 14488-4:2005. At 2.0 kg/m³, the same microfiber grade contributes to passive fire-spall reduction by creating percolated vapor channels after melting at 160 °C to 170 °C; published dosage-response data for this specific configuration remain limited. The resulting in-place lining is a rock support layer, not a substitute for welded wire mesh.
| Verification layer | Standard | Parameter | Typical control |
|---|---|---|---|
| Fiber classification | EN 14889-2:2006 | Class Ia micro polypropylene | length 12 mm, diameter 18 µm |
| Synthetic fiber-reinforced concrete | ASTM C1116/C1116M-23 | Type III fiber | dosage 0.6 kg/m³ to 1.8 kg/m³ |
| Plastic shrinkage cracking | ASTM C1579-21 | restrained cracking resistance | comparative against unreinforced control |
| Sprayed concrete compressive strength | EN 14488-2:2006 | fresh sprayed concrete strength | design class per project |
| Repair overlay compatibility | ASTM C928/C928M-20a | bonded repair performance | pre-wetted substrate ICRI CSP 5 |
| Screed mechanical strength | EN 13892-2 | flexural and compressive strength | class per floor loading |
Demolding of 80 mm-thick C50/60 architectural precast panels after 16 h steam curing at 45 °C imposes edge tensile stress at formed returns and window openings. A dosage of 0.6 kg/m³ MasterFiber M 35 is added to self-compacting concrete with 550 kg/m³ CEM I 52.5 N and slump flow 650 mm per EN 12350-8:2019. The microfiber addition changes the slump flow by less than 20 mm below the control when the dosage remains below 1.0 kg/m³; a 0.1% to 0.2% polycarboxylate ether adjustment by cement weight restores the target flow in production batching. External form vibrators at 50 Hz for 8 s per position consolidate the mix without causing fiber migration to the release-agent interface. Batch-to-batch variance in fiber count after 10 min mixing in a planetary mixer with 10 m/s tip speed is controlled by adding the fiber after the aggregates and before the cementitious powder. The demolded unit is an architectural cladding panel inspected under EN 13670; panels are rejected when visible fiber clusters exceed 3 per 1 m². Published data for the influence of micro PP fibers on demolding stress in thin architectural units is limited, and the observed mitigation of edge tearing is not assigned a structural capacity.
A 25 mm to 50 mm bonded overlay loses surface water rapidly into a substrate prepared to ICRI CSP 5 profile. The C40/50 mortar contains 500 kg/m³ CEM I 42.5 N, water-to-cement ratio 0.40, 4 mm maximum fine aggregate, and 0.9 kg/m³ MasterFiber M 35. The substrate is pre-wetted to a saturated surface-dry condition for 12 h before placement. In hot weather, overlay mixtures with micro PP fibers still develop plastic shrinkage cracks if the evaporation rate exceeds 1.0 kg/m²/h or if the bond coat has cured prematurely before the overlay is placed. Crack width reduction measured on 25 mm restrained coupons under ASTM C1579-21 does not transfer directly to field restraint conditions because shrinkage in repair layers is externally restrained by the substrate roughness. Moist curing under ASTM C309 liquid membrane at 150 g/m² is required. The completed repair layer is specified under ASTM C928/C928M-20a; the fiber contributes only to early-age crack control, with no assigned structural load transfer.
Floors cast on 76 mm trapezoidal galvanized steel deck with total slab depth 130 mm are placed in a high-rise tower on a 3 d to 4 d floor cycle. MasterFiber M 35 is batched at 0.9 kg/m³ into C35/45 pumpable concrete with 10 mm maximum aggregate and slump 180 mm per EN 12350-2:2019. The mix is transported in a truck drum at 12 rpm for 5 min after batching. Pumping through a 125 mm boom line to level 24 does not materially reduce fiber count when the line is primed with a cement paste before concrete discharge. Plastic shrinkage cracking initiates above the steel deck flutes where the cover is 54 mm and the local bleeding is lower. The fibers reduce crack visibility at these locations but do not function as shear reinforcement; composite behavior is carried by welded studs through the steel deck. The slab is struck and power-troweled after surface bleed water clears. Over-finishing can drag fibers to the surface and create fuzz. The floor deck assembly is specified under SDI C-2017, and deck deflection criteria follow AISC Design Guide 11.
MasterFiber M 35 is incorporated at 0.6 kg/m³ to 0.9 kg/m³ in a cementitious underlayment screed with 4 mm maximum aggregate, water-to-cement ratio 0.45, and flow diameter 250 mm to 300 mm under ASTM C1437. The fiber length of 12 mm is below one-fifth of the minimum pump line diameter and below one-third of the minimum 40 mm bonded screed thickness, preventing filter-blocking at the rotor-stator pump. The cured underlayment is a bonded or unbonded screed beneath vinyl, tile, or resin flooring. The fiber reduces plastic shrinkage tears but does not increase flexural strength classified under EN 13813:2002. Performance is verified under EN 13892-2 for flexural and compressive strength. Field batches show occasional fiber accumulation at the suction hopper screen if the fibers are added before the water; the preferred sequence is to add fibers to the slurry after the powder is uniformly wetted. Two separate batches are checked for flow retention at 30 min; variance is within 10 mm when the dosage is constant.
Cast-in-place basement slabs of 300 mm thickness are placed against a blinding layer and perimeter pile caps. The concrete C30/37 with 0.9 kg/m³ MasterFiber M 35 is poured by direct chute or pump. Restraint from soil friction, starter bars, and pile cap dowels generates tensile surface strain during early thermal contraction. The microfiber grade does not reduce the diffusion coefficient of chloride or water in hardened concrete; watertightness is controlled by joint design under ACI 350-20 and by waterstop installation. Early-age crack width under restrained conditions is evaluated comparatively by ASTM C1581-18a ring testing; the ring test provides comparison rather than a direct design value. Fiber addition is compatible with polycarboxylate ether and lignosulfonate admixtures at normal dosages. The basement slab is a water-excluding structural element with reduced incidental surface cracking but no change in the structural crack-control reinforcement required by EN 1992-1-1:2004 or ACI 318-19.
Competitive MasterFiber M 35 - Monofilament Micro Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
MasterFiber M 35 is a monofilament micro polypropylene fiber supplied for direct addition to concrete, shotcrete, and cementitious screeds. The product is introduced as a collated bundle of circular filaments that separates under normal mixer shear. Technical literature for MasterFiber M 35 identifies a nominal filament length of 12 mm, a specific gravity of 0.91, and negligible water absorption. The fiber is specified where plastic shrinkage cracking in slabs, pavements, bridge decks, and precast units must be limited before initial set. Under ASTM C1116/C1116M, the product falls within Type III synthetic fiber-reinforced concrete and shotcrete. Under EN 14889-2:2006, polymer fibers for concrete require initial type testing and factory production control; MasterFiber M 35 is placed on the market with performance documentation consistent with this harmonized framework.
Plastic shrinkage cracks initiate when surface evaporation removes bleed water faster than it can be replaced from below. Capillary menisci form in the paste and generate tensile stress that exceeds the low tensile strain capacity of fresh concrete. A micro monofilament distributed through the paste acts as a local stress distributor that reduces maximum crack width and total crack area, but it does not change the driving evaporation rate. The hot-weather concreting guide ACI 305R-20 provides an evaporation-rate model based on air temperature, relative humidity, concrete temperature, and wind speed. When the calculated evaporation rate exceeds 0.5 kg/m²/h, the risk of plastic shrinkage cracking remains high even with microfibers.
In restrained slab tests under ASTM C1579-21, class-level studies on monofilament polypropylene microfibers dosed at 0.9 kg/m³ have reported reductions in total crack area of 40% to 80% relative to plain control specimens. The range is broad because aggregate type, paste volume, cement fineness, and finishing timing all interact with fiber efficiency. Published multi-laboratory data specific to MasterFiber M 35 is limited; therefore, a project-specific preconstruction slab test is required when crack-width or crack-area reduction is a contract acceptance criterion. The fiber should not be interpreted as a substitute for early moist curing, evaporation retardants, windbreaks, or fogging systems.
The mechanism is distinct from that of shrinkage-reducing admixtures. Shrinkage-reducing admixtures lower the surface tension of pore solution, whereas polypropylene fibers provide mechanical restraint against early microcrack opening. In low water-cementitious material ratios below 0.40, autogenous shrinkage and plastic shrinkage can act simultaneously, and the fiber may be combined with an internal curing agent or shrinkage-reducing admixture only after compatibility testing with the specific high-range water reducer.
Batching and mixing sequence controls fiber dispersion. In ready-mix operations, the fiber should be added after the aggregates and before or during the initial portion of batch water. If the fiber is added first to an empty drum, it can remain in the drum fins and create uneven distribution. Central mixer trials show that monofilament micro fibers disperse more uniformly than fibrillated micro fibers at the same fiber volume because the circular cross-section reduces interfilament entanglement during screw conveying and transfer. Twin-shaft mixers with a working volume of 1.0–3.0 m³ typically require 4–5 minutes of wet mixing after all constituents are charged for visual homogeneity. Truck mixers may require 70–100 revolutions at mixing speed. Overmixing beyond 120 revolutions does not degrade polypropylene filaments at concrete temperatures below 40°C, but it can increase paste viscosity and reduce workability in low-slump mixtures.
The product packaging is designed for direct introduction into the mixer. Bags are typically cellulose and disintegrate under mixing; the fiber does not require pre-slaking or pre-dispersion. For high-speed pan mixers in precast plants, the fiber is added after the dry-blend of aggregates and cement has been premixed for 30–60 seconds to avoid fiber accumulation on the pan lining. In very dry mixes with moisture content below 2%, static charge may cause monofilaments to cling to metal surfaces; increasing batch moisture above that threshold or reducing mixer speed temporarily resolves this processing condition.
The table below lists representative physical values for MasterFiber M 35. Where the product class is cited, the value should be confirmed against the batch certificate for the specific lot supplied. The product is characterized by a round monofilament cross-section rather than a fibrillated tape. This shape affects specific surface area, dispersion behavior, and finishing response.
| Property | Reported value | Reference method |
|---|---|---|
| Fiber geometry | Monofilament, circular cross-section | Optical microscopy |
| Nominal filament length | 12 mm | EN 14889-2:2006 Annex A |
| Equivalent diameter | 18–22 µm | Optical microscopy |
| Specific gravity | 0.91 | ASTM D792-20 |
| Tensile strength | 300–550 MPa | ASTM D3822-20 |
| Tensile modulus | 3.5–4.0 GPa | ASTM D3822-20 / ASTM D638-14 |
| Melting point | 160–170°C | Differential scanning calorimetry |
| Water absorption | <0.1% | ASTM D570-22 |
| Alkali resistance | No significant degradation after 28 days in saturated Ca(OH)₂ at 20°C | EN 14889-2:2006 |
The melting point and tensile modulus are relevant in elevated-temperature curing and in service. Polypropylene softens near 160–170°C, which places an upper service limit on concrete elements exposed to continuous heat. The fiber does not ignite at normal mixing temperatures and is chemically stable in alkaline pore solution; laboratory immersion in saturated calcium hydroxide maintained at 20°C for 28 days does not cause measurable depolymerization. The water absorption value is below 0.1%, which means the fiber does not compete for mix water during slump control.
Physical properties reported for monofilament polypropylene fibers are sensitive to test speed and gauge length. Single-filament tensile testing under ASTM D3822-20 requires a constant rate of elongation and correction for cross-sectional area derived from optical microscopy. Values outside the stated range can occur due to extrusion parameters and draw ratio; procurement specifications should require a certificate of analysis showing fiber length distribution, diameter, and tensile strength for each production batch.
Finishing of slabs containing MasterFiber M 35 differs from plain concrete because the fiber suppresses early bleed. The surface may reach the troweling window earlier than a plain mix of the same slump. The normal practice is to begin floating when the water sheen disappears, not at a fixed time after strikeoff. Power trowels with float blades should be set at 20–30° angle during the first pass; high blade angle at early age can tear the surface and expose fibers. If fibers are visible on the surface, a light misting followed by troweling will usually re-embed them; prolonged addition of water to assist finishing is not permitted because it increases the surface water-cementitious ratio and weakens the wearing surface. On exterior slabs, broom finishing after troweling is unaffected by the presence of microfibers.
Because the fiber is a fine monofilament, it does not produce the fuzzy surface associated with some fibrillated fibers. However, it can be drawn upward by overworking the surface. ACI 302.1R-15 recommends limiting the number of trowel passes and using only steel trowels when the surface has sufficient stiffness to ring under foot traffic.
At 0.9 kg/m³, the product provides a dense filament count in the paste fraction without a measurable reduction in slump when the aggregate moisture content is stable. At a nominal diameter of 20 µm and length of 12 mm, the calculated fiber count at 0.9 kg/m³ is approximately 2.6 × 10⁸ filaments per cubic metre, assuming specific gravity 0.91. Fiber addition can increase entrapped air by 0.5 to 1.0 percentage points in non-air-entrained mixtures, and the air content should be checked at the point of discharge using ASTM C231/C231M-17a if the mix is specified for exterior exposure. In air-entrained concrete, the fiber addition does not typically interfere with the formation of an adequate air-void system, but the air-entraining admixture dose may require a 5–10% increase to maintain the same total air content after fiber addition.
When the dosage is increased to 1.8 kg/m³, paste viscosity increases and workability loss becomes measurable. A Type F high-range water reducer complying with ASTM C494/C494M is commonly used to offset the workability loss at higher fiber dosages. Fiber clustering can occur if the fiber is added to a mix with high paste viscosity before the water-reducing admixture is fully dispersed; the batching sequence should ensure that the high-range water reducer is added before the fiber or simultaneously with the final water. In dry-cast, zero-slump concrete, dosages above 1.2 kg/m³ are generally avoided because the fiber can bridge narrow mold openings and produce surface voids on exposed faces.
The product is not a substitute for welded wire mesh in slabs that require crack-width control after hardened concrete is subjected to drying shrinkage and thermal contraction. Its length and modulus are too low to provide post-crack residual strength at crack widths above 0.2 mm. If the project requires structural crack control, a macro-synthetic or steel fiber with a length of 40–60 mm and a dosage determined by ASTM C1399/C1399M residual strength testing should be used instead.
In dry-mix shotcrete, MasterFiber M 35 is pre-blended with cement and aggregates before the gun. Field experience on production-scale dry-mix rotary equipment indicates that the monofilament does not plug the feed bowl when the moisture content of the dry premix is held below 0.3%; above this threshold, moisture-induced clumping and static charge can reduce feed uniformity. In wet-mix shotcrete, the fiber is added at the batch plant or in the truck mixer. Pumping through 50 mm ID dense-stream lines is possible with dosages up to 1.8 kg/m³ provided the line pressure is monitored; monofilament fibers do not contribute to line blockages in the same manner as steel fibers, but sharp bends and reducers should be avoided because fiber accumulation can occur at restrictions. The product is not intended to replace steel fibers in structural shotcrete linings requiring toughness measured by ASTM C1550-20.
Product selection among synthetic fibers should account for geometry and test-standard requirements rather than dosage alone. Fibrillated microfibers are produced as an expanded tape that splits into a net-like structure during mixing; monofilament M 35 is extruded as a continuous round filament and cut to 12 mm. The circular geometry reduces the tendency for fiber balling in low-slump concrete and improves surface finish after steel troweling. However, fibrillated geometry provides a different interaction with cement paste at the microscopic level, and the two forms should not be interchanged without requalification of the mix.
| Fiber type | Nominal length | Tensile strength | Primary function | Typical dosage |
|---|---|---|---|---|
| MasterFiber M 35 monofilament micro | 12 mm | 300–550 MPa | Plastic shrinkage crack control | 0.9–1.8 kg/m³ |
| Fibrillated polypropylene micro | 19–25 mm | 300–500 MPa | Plastic shrinkage crack control; higher balling tendency | 0.9–1.8 kg/m³ |
| Macro-synthetic polypropylene | 40–60 mm | 550–700 MPa | Post-crack residual strength | 3–7 kg/m³ |
| Steel fiber | 35–60 mm | 1100–1500 MPa | Post-crack toughness and structural capacity | 20–40 kg/m³ |
The comparative matrix illustrates the performance boundary. MasterFiber M 35 occupies the plastic shrinkage control range, not the post-crack toughness range. If a specification requires average residual strength ratio I5 or I10 under ASTM C1399/C1399M of at least 20%, a macro-synthetic or steel fiber is required. Attempting to use M 35 at higher dosages to meet post-crack criteria is technically invalid because the monofilament lacks sufficient length and anchorage to bridge hardened concrete cracks beyond 0.2 mm.
Compared with steel fibers, the polypropylene monofilament has no corrosion risk and is substantially lighter, which simplifies handling and reduces wear on mixer internals. Compared with macro-synthetic fibers, the micro monofilament has a higher number of fibers per unit mass and therefore greater influence on plastic-state cracking, but it does not provide the same post-crack load transfer. Compared with fibrillated microfibers, the monofilament can be finished with less effort and is less likely to protrude after power troweling.
Operational boundaries are set by the polypropylene chemistry and small filament diameter. The fiber should not be used in refractory concrete or in applications where continuous service temperatures exceed 80°C, because mechanical properties decline as the melting point near 160°C is approached. The product is not compatible with strong oxidizing agents or with matrices that require electrical conductivity. Storage above 60% relative humidity can weaken paper packaging through condensation, although the fiber itself is hydrophobic and does not require pre-drying. When stored on site, bags should be kept on pallets off the ground and protected from rain and direct sunlight. The product is not a substitute for structural reinforcement, post-tensioning, or joint design; crack-width control in hardened concrete remains a function of reinforcement detailing, concrete shrinkage, and restraint conditions. Compliance documentation includes safety data sheets and CE marking under EN 14889-2:2006; local occupational exposure limits should be confirmed for each project location.