| HS Code | 326444 |
| Product Name | MasterFiber M 70 - Monofilament Micro Polypropylene Fiber |
| Manufacturer | Master Builders Solutions |
| Fiber Type | Monofilament |
| Material | 100% virgin polypropylene |
| Color | White |
| Fiber Length | 12 mm (0.5 in) |
| Equivalent Diameter | 0.022 mm (0.00087 in) |
| Tensile Strength | 400 MPa (58,000 psi) |
| Young S Modulus | 3.5 GPa (500,000 psi) |
| Melting Point | 160 °C (320 °F) |
| Ignition Point | 590 °C (1094 °F) |
| Alkali Resistance | Excellent |
| Water Absorption | Nil |
| Dosage | 0.9 kg/m³ (1.5 lb/yd³) |
| Packaging | 0.9 kg (2 lb) bags; 18 kg (40 lb) boxes |
| Compliance | ASTM C1116 Type III; EN 14889-2 Class I |
As an accredited MasterFiber M 70 - Monofilament Micro Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | MasterFiber M 70 comes in 600 g water-soluble bags, 20 bags per carton (12 kg total). |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized MasterFiber M 70 monofilament micro polypropylene fiber bags, shrink-wrapped and secured for ocean export. |
| Shipping | Transport classification: Not regulated as dangerous goods (non-hazardous). UN number/Proper shipping name: Not applicable. MasterFiber M 70 is shipped in sealed moisture-resistant bags or sacks, palletized and secured. Store dry, avoid punctures, and follow local transport regulations. No special transport placards required. |
| Storage | Store MasterFiber M 70 in original, unopened packaging in a cool, dry, well-ventilated area. Protect from moisture, direct sunlight, heat, sparks, and open flames. Keep containers closed, avoid dust accumulation, and prevent contamination. Do not store outdoors or in damp conditions. Maintain stable pallets, avoid puncturing bags, and follow FIFO rotation and manufacturer shelf-life guidelines. |
| Shelf Life | Shelf life is 12 months from manufacture when stored unopened in original packaging, dry, and protected from moisture and sunlight. |
In jointed slab-on-ground industrial flooring, MasterFiber M 70 is introduced at the ready-mix plant at a dosage of 0.6–0.9 kg/m³, with 0.9 kg/m³ specified when plastic shrinkage cracking is evaluated under ASTM C1579-21. The fibre conforms to ASTM C1116/C1116M Type III synthetic fibre requirements and is placed under EN 14889-2:2006 Class II for polymer fibres, while ready-mix supply remains governed by ASTM C94/C94M, including plant batching, mixing revolution limits, and discharge temperature constraints. In truck-mixer operations, degradable fibre bags are added after aggregate and cement fractions, followed by mixing at 12–15 rpm for 70–100 revolutions before discharge; because monofilament polypropylene does not absorb mix water but increases plastic viscosity, slump adjustment is managed with water-reducing admixture rather than free water raise. Placement proceeds by laser-guided screed or conventional strike-off and bull float, while power trowel timing is linked to bleed-water disappearance, which shifts earlier under evaporation rates above 1.0 kg/m²/h defined in ACI 305R-20. Terminal product types include high-bay warehouse slabs, logistics centre floors subject to narrow-aisle racking loads, freezer floor slabs with reduced joint-edge spalling, and exterior apron slabs exposed to wind and direct sun during finishing.
The behaviour of monofilament polypropylene in dry-mix shotcrete is governed by pneumatic transport rather than mixer shear alone. MasterFiber M 70 is batched into the dry pre-mix at 0.9 kg/m³, with whole-bag addition made at the pug mill or pan mixer after 30 s of dry aggregate and cement blending. The applicable placement documents are ACI 506R-16 and ASTM C1436/C1436M; fibre conformity is established under EN 14889-2:2006 Annex ZA, and crack reduction can be separately evaluated by ASTM C1579-21. In dry-mix transport, the prepared mixture is conveyed through a placement hose at 0.6–0.7 MPa air pressure and wetted at the water ring within 1.0–1.5 m of the nozzle; fibre addition at the nozzle is avoided because immediate water contact before impact produces localised clumping at the water ring. Tunnel lining field observations indicate that wet-mix processes with synthetic microfibre can develop pump blockages if the full bag is discharged too late in high-shear truck mixing, so the fibre is added after batching and before final 70 revolutions. Dry-mix rebound reduces the effective in-place fibre count, and published comparative rebound data for this specific monofilament configuration under variable air pressure and nozzle distance is limited, therefore site verification under EN 14487 is required to confirm rebound-adjusted dosage. Terminal product types include rock slope stabilisation, NATM tunnel primary linings, culvert and portal lining repairs, and underground opening support requiring early-age crack control before final lining installation.
| Application context | Standard / code | Conformity item |
|---|---|---|
| Ready-mix slab-on-ground concrete | ASTM C94/C94M | Plant batching, mixing revolutions, discharge limits |
| Ready-mix slab-on-ground concrete | ASTM C1116/C1116M | Type III synthetic fibre specification |
| Dry-mix shotcrete | ACI 506R-16 | Sprayed concrete guide and process selection |
| Dry-mix shotcrete | ASTM C1436/C1436M | Materials for shotcrete placement |
| Precast dry-cast pavers | ASTM C936/C936M | Solid interlocking concrete paving unit requirements |
| Bonded overlays and repair mortars | EN 1504-3 | Structural and non-structural repair product classes |
| Marine and water-retaining concrete | ACI 350-20 | Environmental concrete crack width and durability limits |
| All concrete applications | EN 14889-2:2006 Annex ZA | CE marking for Class II polymer fibres |
| Self-compacting architectural precast | EN 12350-8 | Slump-flow test method for SCC consistency |
Compaction-dominated dry-cast production inserts a different dosage logic. MasterFiber M 70 in concrete pavers and segmental retaining wall units is generally added at 0.6 kg/m³, not because crack reduction is less necessary but because the vibration/press compaction cycle must remain within the block machine’s available energy envelope. The product is still classified as a Type III synthetic fibre under ASTM C1116/C1116M and is included in mixes conforming to ASTM C936/C936M for solid interlocking paving units where applicable. In production, the fibre is dry-blended with coloured or grey zero-slump concrete before the mixture is fed into the mould cavity, where a press head and vibrator table deliver compaction acceleration typically in the range of 45–60 Hz depending on the block machine. Standard 60 mm paver cycle times fall between 8 and 12 s; at the upper dosage boundary of 0.9 kg/m³, lower-compaction-energy machines can exhibit pattern distortion or edge slump, and published data for this specific paver-machine configuration is limited, so mill trials using 20–30 cycles per batch are used before full production. Terminal product types include interlocking concrete pavers, permeable paving units for stormwater control, segmental retaining wall blocks, and dry-cast patio slabs.
Bonded overlays and repair mortars are high-surface-area placements where evaporation and substrate suction act simultaneously during the first 6 hours. For this context, MasterFiber M 70 is charged at 0.9 kg/m³ into the mortar or concrete batch and mixed in a high-shear paddle mixer at 400–600 rpm for 3–5 minutes; manual bag addition is made after dry materials and before the gauging water reaches full volume to prevent floating fibre clumps at the mixer wall. Repair system compliance is established under EN 1504-3 for repair products and ASTM C928/C928M for packaged rapid-hardening hydraulic cement repair materials where applicable, while the fibre maintains EN 14889-2:2006 conformity. The substrate is prepared to saturated-surface-dry condition and a bonding coat is applied before the overlay is placed at 20–50 mm thickness. Because the monofilament increases plastic viscosity, edge slump at repaired spalls is lower than unreinforced control mixes, but the finishing window shortens; power trowel or damp-sponge finishing is initiated once the surface sheen disappears, and wet curing or a curing membrane is applied before moisture loss exceeds 0.5 kg/m² in the first 4 hours. Terminal product types include bridge deck overlays, parking structure repair slabs, loading dock resurfacing screeds, and bonded concrete overlays for industrial ramps and thresholds.
In marine and water-retaining concrete structures, the dominant quality risk is evaporation-driven surface crazing at the time of initial set, particularly when wind speed exceeds 20 km/h and ambient temperature exceeds 35 °C. MasterFiber M 70 is dosed at 0.9 kg/m³ in mixes for desalination plant slabs, wastewater clarifier walls, canal linings, and secondary containment bunds. The applicable structural and durability codes include ACI 350-20 for environmental concrete structures, EN 206 for exposure classes, and ASTM C1116/C1116M for fibre specification. In central-mix plants, the fibre is introduced into the mixer after coarse aggregate but before cement, and mixing continues for 60–90 s after fibre addition. Pump placement through a 125 mm or 150 mm line is used for walls and deep slabs; the fibre does not replace steel reinforcement for structural load-bearing capacity, but acts to reduce early-age cracking before curing takes effect. Evaporative condition is monitored under ACI 305R-20, and when evaporation rate exceeds 1.0 kg/m²/h, fogging or evaporation retardants are required even with fibre present. Terminal product types include seawater intake slabs, brine holding pond linings, wastewater treatment basin walls, and secondary containment bunds around chemical storage in port facilities.
When architectural precast panels are cast with self-compacting concrete, MasterFiber M 70 is added less for crack suppression alone and more for anti-bleed stabilisation and plastic settlement control at form-face boundaries. The dosage in these mixes is typically 0.6–0.9 kg/m³, with 0.6 kg/m³ used where a 650–750 mm slump flow and painted form-face finish are specified. Conformity of the fibre remains under EN 14889-2:2006 and ASTM C1116/C1116M, while the concrete itself is tested according to EN 12350-8 for slump flow and ASTM C1611/C1611M for passing ability. In production, the fibre is dry-blended in a planetary counter-current mixer before the superplasticiser is introduced; reverse-pan mixing at 12–18 rpm for 90–120 s distributes the monofilament without destroying the air-void system required for freeze-thaw durability. The operational boundary is that dosage above 0.9 kg/m³ in SCC can reduce slump flow by 20–40 mm and may require additional superplasticiser, but that adjustment can alter form-face air migration. Terminal product types include architectural facade panels, thin-section balcony elements, sound barrier panels, and precast interior wall panels with exposed aggregate surfaces.
Competitive MasterFiber M 70 - Monofilament Micro Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
MasterFiber M 70 is a monofilament micro polypropylene fiber specified for use as a concrete admixture in cementitious systems. The product is classified under EN 14889-2:2006 as a Class I polymer microfibre and may be cited in specifications under ASTM C1116/C1116M-23 as a Type III synthetic fibre-reinforced concrete material. Published product data list a polymer density of 0.91 g/cm³, a nominal filament length of 12 mm, and a nominal filament diameter of 18 µm. The corresponding aspect ratio is 667. At the reference dosage of 0.9 kg/m³, the calculated filament count is approximately 3.2 × 10⁸ discrete fibres per cubic metre, and the theoretical filament surface area is approximately 220 m²/m³. The product is supplied as individually cut monofilament strands, not as a fibrillated tape or macro-synthetic structural fibre. Its primary function is to reduce plastic shrinkage cracking in fresh concrete by increasing the strain capacity of the paste phase and by interrupting bleed-water channel formation during the first 24 h after placement.
The polymer is a polypropylene homopolymer. In cementitious pore solution, the fibre is insoluble and does not undergo measurable hydrolysis under saturated calcium hydroxide exposure, which is referenced in the manufacturer’s conformity documentation under EN 14889-2:2006. Moisture absorption is reported as <0.1 % when tested in accordance with ASTM D570-22. No water absorption correction is therefore applied during batch proportioning. MasterFiber M 70 does not function as primary structural reinforcement. It does not replace load-bearing steel reinforcing bars, and it does not provide post-crack residual flexural strength measured under EN 14651:2005+A1:2007.
The monofilament geometry separates MasterFiber M 70 from fibrillated polypropylene micro products. Fibrillated fibres are produced as expanded tapes that must split into connected filaments during mixing; dispersion therefore depends on mixer shear energy and can be less complete in low-slump dry-cast concrete. A monofilament enters the mixer as an already divided filament, which reduces the probability of entangled ball formation and permits addition through automated dosing systems without manual bag opening. Tensile modulus is substantially below that of steel fibre, and the design function is plastic shrinkage crack control rather than post-crack load-bearing capacity. Table 1 provides comparative values across common fibre classes.
| Attribute | MasterFiber M 70 micro monofilament | Fibrillated micro polypropylene | Macro-synthetic polypropylene | Hooked-end steel fibre |
|---|---|---|---|---|
| Material base | Polypropylene homopolymer | Polypropylene homopolymer | Polypropylene or copolymer | Cold-drawn steel wire |
| Density | 0.91 g/cm³ | 0.91 g/cm³ | 0.90–0.92 g/cm³ | 7.85 g/cm³ |
| Nominal length | 12 mm | 12–19 mm | 40–60 mm | 35–60 mm |
| Nominal diameter or equivalent | 18 µm | 0.1–0.3 mm | 0.3–1.0 mm | 0.5–1.0 mm |
| Typical dosage | 0.6–1.2 kg/m³ | 0.6–1.5 kg/m³ | 3.0–9.0 kg/m³ | 15–60 kg/m³ |
| Primary design function | Plastic shrinkage crack control | Plastic shrinkage crack control | Post-crack flexural toughness | Post-crack flexural toughness and structural crack control |
Unlike steel fibre systems, MasterFiber M 70 introduces no corrosion mechanism in chloride-exposed concrete and does not alter electromagnetic or induction field behaviour. It is not a substitute for macro-synthetic or steel fibres where EN 14651:2005+A1:2007 residual flexural strength classes are required. At 0.9 kg/m³, the product is specified as a micro synthetic fibre for early-age crack control, not as a structural macro fibre.
For specification and quality assurance, MasterFiber M 70 is ordered by fibre length, polymer type, and compliance with EN 14889-2:2006. The certificate of conformity should state the declared filament geometry, reference dosage, and results for tensile strength, modulus, and alkali resistance. Because batch-to-batch changes in polymer melt rheology can influence filament diameter and cut length, the manufacturer’s statistical process control data should be reviewed for projects requiring documented uniformity. The compliance matrix in Table 2 summarizes verification standards relevant to the product.
| Requirement | Standard or test method | Typical value or status |
|---|---|---|
| CE marking for polymer fibres for concrete | EN 14889-2:2006 | Class I polymer microfibre |
| Fibre-reinforced concrete specification | ASTM C1116/C1116M-23 | Type III synthetic fibre |
| Plastic shrinkage cracking evaluation | ASTM C1579-21 | Comparative performance test |
| Density | ISO 1183-1:2019 | 0.91 g/cm³ |
| Tensile strength of monofilament | ASTM D3822/D3822M-20 | 300–400 N/mm² |
| Melting temperature | ISO 11357-3:2018 | 160–165 °C |
| Moisture absorption | ASTM D570-22 | <0.1 % |
Addition sequence controls dispersion quality. In ready-mix plants using inclined drum mixers with batch volumes of 4–12 m³, the water-soluble fibre bags are commonly added after 80 % of batch water and aggregates are charged, followed by 5 min of mixing at 12–18 rpm. The packaging disperses without manual opening. In dry-cast and precast operations using pan or planetary mixers, dry pre-blending with sand for 30–60 s before cement addition reduces static-induced clustering. If the fibre is discharged directly into cement-rich paste at the start of batching, visual balling may occur, particularly at dosages above 1.0 kg/m³.
Slump retention should be verified by ASTM C143/C143M-20 because the increase in fibre surface area can reduce workability in low-water mixes. The fibre itself contributes no absorption-based water demand, but high filament count can increase plastic viscosity. Mix designs with a water-to-cement ratio below 0.40 often require a high-range water reducer conforming to ASTM C494/C494M Type F or EN 934-2 to maintain the specified slump. The required admixture adjustment is determined by plant trial, not by a fixed value.
Air content should be monitored when the fibre is combined with air-entraining admixtures. The hydrophobic fibre surface can interact with air void stabilizers, and preconstruction trials should include air content measurement by ASTM C231/C231M-17a. If air content falls below specification, the air-entraining admixture dosage should be adjusted incrementally at the batch plant. The fibre is not classified as compatible with dry blending with powdered air-entraining formulations unless verified by full-scale trial.
Storage conditions impose an operational boundary. Unopened packages should remain protected from condensation and stored below 35 °C and 60 % relative humidity. If bags are exposed to moisture, the water-soluble packaging may soften prematurely and fused fibre clusters may form. Such product should not be batched. No predrying of the fibre is required under normal storage, but clumped or discoloured material should be rejected.
Plastic shrinkage cracking occurs when the evaporation rate from a fresh concrete surface exceeds the bleeding rate, producing tensile stress in capillary water menisci between aggregate particles. MasterFiber M 70 counteracts this mechanism by providing a large number of fine filaments that bridge microcracks during the setting phase. Under ASTM C1579-21, evaluation is based on crack area reduction relative to a plain reference mix at a fixed dosage. Published data for this specific product configuration is limited in open-source literature; project-specific testing is required when crack width is an acceptance criterion.
Performance is dosage-sensitive. At 0.6 kg/m³, filament density may be insufficient to intersect the full crack network under severe drying conditions. At 1.2 kg/m³, finishing operations may expose filaments at the slab surface, particularly with power trowels. The reference dosage of 0.9 kg/m³ is specified for slab-on-grade construction where crack control and finishability are both required. The product is not designed to eliminate hardened concrete drying shrinkage cracking; it primarily addresses the plastic state before final set.
In precast facade elements and tunnel segments, micro polypropylene fibre addition has been used to reduce early-age surface cracking induced by thermal gradients. Published data for MasterFiber M 70 in fire-exposed high-strength concrete is limited; project-specific furnace testing on the target mix design is necessary before specifying the material for spalling resistance under ISO 834-1:1999. In wet-mix shotcrete, addition at the batch plant at 0.9 kg/m³ is used to reduce rebound and control early-age cracking on vertical and overhead profiles. The product does not replace macro-synthetic or steel fibres for flexural toughness measured by EN 14488-3:2006.
When substituting MasterFiber M 70 into an existing mix design, the following checks should be recorded: air content by ASTM C231/C231M-17a, slump by ASTM C143/C143M-20, and visual inspection of the hardened surface for fibre bundling. Any dosage above 1.2 kg/m³ should be validated in a full-scale production trial before release for placement.