Sika Fibermesh 150F - Micro-Synthetic Monofilament Fiber for Resistance to Fire Spalling

    • Product Name: Sika Fibermesh 150F - Micro-Synthetic Monofilament Fiber for Resistance to Fire Spalling
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 343681
    Product Name Sika Fibermesh 150F
    Manufacturer Sika
    Product Type Micro-synthetic monofilament fiber
    Primary Function Resistance to fire spalling
    Material Polypropylene
    Form Monofilament
    Color Natural
    Fiber Length 6 mm
    Fiber Diameter 0.018 mm
    Aspect Ratio 333
    Density 0.91 g/cm³
    Specific Gravity 0.91
    Melting Point 160 °C
    Ignition Temperature >350 °C
    Tensile Strength 350 MPa
    Elastic Modulus 3.5 GPa
    Water Absorption <0.1%
    Alkali Resistance Excellent
    Non Corrosive Yes
    Dosage 0.6–1.8 kg/m³
    Packaging 1 kg bag
    Shelf Life 24 months
    Storage Dry conditions
    Fire Spalling Mechanism Melts to create pressure-relief channels
    Compliance EN 14889-2

    As an accredited Sika Fibermesh 150F - Micro-Synthetic Monofilament Fiber for Resistance to Fire Spalling factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Sika Fibermesh 150F packaging: 600 g bags, supplied 20 bags per carton (12 kg total).
    Container Loading (20′ FCL) 20′ FCL container loaded with palletized Sika Fibermesh 150F micro-synthetic monofilament fiber, shrink-wrapped and securely strapped for safe ocean transport.
    Shipping Sika Fibermesh 150F is shipped as a non-hazardous, non-flammable synthetic fiber in sealed, moisture-resistant bags or pails, palletized and shrink-wrapped. Store cool and dry, away from moisture, ignition sources, and incompatible materials. Not regulated as dangerous goods for transport; no UN number, class, or packing group. Follow SDS and local transport rules.
    Storage Store Sika Fibermesh 150F in its original, unopened packaging in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, sparks, flames, and moisture. Elevate off the floor and protect from physical damage. Maintain sealed bags until use; observe shelf life. Do not stack excessively; use first-in, first-out stock rotation. Follow SDS/local regulations.
    Shelf Life Sika Fibermesh 150F has a 24-month shelf life from production when stored dry, unopened, and protected from direct sunlight at 5–30°C.
    Application of Sika Fibermesh 150F - Micro-Synthetic Monofilament Fiber for Resistance to Fire Spalling

    Fire-induced spalling in dense, low-permeability concrete is a vapour-pressure-driven failure mode. When the cementitious matrix has a water/cement ratio at or below 0.42 and a compressive strength class of C60/75 or higher, capillary porosity is insufficient to vent steam generated at the heated face. Sika Fibermesh 150F, dosed as a monofilament micro-synthetic addition at 1.0–3.0 kg/m³, introduces a temperature-sensitive percolation network. At approximately 160–170°C, the monofilaments melt and leave channels that permit pore pressure dissipation before the tensile capacity of the hot concrete is exceeded. This mechanism is addressed within EN 1992-1-2:2004, Clause 4.5, where spalling is evaluated separately from load-bearing resistance and thermal insulation. For bored tunnel segmental linings, the relevant thermal exposure is commonly the Rijkswaterstaat RWS curve, which reaches 1,350°C and remains above 1,200°C for a prolonged period. Concrete producers evaluate such linings not by calculation alone but by furnace testing because the spalling response is controlled by moisture content, aggregate type, section thickness, load level and heating rate.

    Segmental ring production for TBM tunnels typically uses C50/60 to C70/85 concrete with silica fume at 5–10% by mass of cementitious material and a water/cementitious ratio between 0.30 and 0.38. The monofilament fiber is added either onto moist aggregate before cement and silica fume are introduced, or through a vibratory chute onto the wetted mix at the start of mixing. Field observations from carousel precast lines with twin-shaft compulsory mixers indicate that dumping entire bag loads into dry cement produces localized fiber clusters; sequential dosing through a vibratory feeder reduces this batch-to-batch variance. After mixing, the concrete is cast into steel segment moulds, compacted on external vibrators, and steam cured to achieve early demoulding. The terminal component is a precast ring segment with formed gaskets, bolt boxes and tolerance faces. Fire acceptance is generally based on loaded slab or panel specimens tested under the RWS curve in accordance with EN 1363-1:2020 and ISO 834-1:1999, with pass criteria covering specimen integrity, insulation and the absence of explosive spalling. The fiber addition must be verified after curing because prolonged exposure to high ambient temperatures during summer batching can reduce air content control and increase superplasticizer demand, which affects pumpability and mould filling.

    ApplicationConcrete classIndicative fiber additionFire curvePrimary test/acceptance standard
    TBM tunnel segmentC50/60–C70/851.5–3.0 kg/m³RWSEN 1363-1:2020, ISO 834-1:1999
    High-rise coreC80/951.5–2.0 kg/m³ISO 834EN 1992-1-2:2004, ISO 834-1:1999
    Precast hollowcoreC60/75–C70/851.5–2.0 kg/m³ISO 834EN 1363-1, BS 476-20
    Wet-mix shotcreteC50/602.0 kg/m³RWS/HCMEN 14488-3, EN 1363-1
    Industrial slabC40/501.5 kg/m³Hydrocarbon pool fireEN 1991-1-2, EN 1363-1
    Precast parking deckC60/751.0–1.5 kg/m³ISO 834EN 1363-1, UL 263
    Rail station boxC70/852.0 kg/m³RWS/HCMEN 1363-1:2020

    Dosage ranges in the matrix are indicative and are derived from commonly published fire-test programmes for dense, low-permeability concretes. Project-specific verification is required because aggregate thermal expansion, moisture condition, section geometry and applied load all shift the spalling threshold independently of fiber addition.

    Does 2 kg/m³ Addition Persist Through Extended Mixing and Pumping in High-Rise Core Concrete?

    High-rise shear walls and column cores cast with C80/95 concrete combine low water/cementitious ratios, silica fume and high cementitious contents, producing the low permeability profile associated with explosive spalling under the ISO 834-1:1999 cellulosic curve. When 2.0 kg/m³ of monofilament micro-synthetic fiber is introduced, the principal processing concern is not initial slump loss but fiber distribution under long pumped deliveries and extended truck-mixer agitation. Polypropylene has a density near 0.91 g/cm³, which is lower than the paste fraction, and its monofilament geometry resists uniform dispersion if added too rapidly. Production-scale observations in high-rise core pours show that automated addition onto the aggregate conveyor, rather than direct addition into the truck drum, reduces visible fiber agglomeration and improves post-pumping uniformity. Extended agitation beyond 90 minutes at high concrete temperatures can increase air content and cause measurable slump reduction; the mix should be adjusted with a polycarboxylate superplasticizer rather than adding water. The interval between batching and pumping should be recorded, and the air content of the fresh concrete should be checked under EN 12350-7:2019. For fire performance, acceptance is normally based on loaded column or wall tests under ISO 834-1:1999, with limits on spalling depth, residual cross-section and unrestrained strain. Published data for this specific high-rise configuration is limited, so test panels should be conditioned to the same moisture content as the in-service core.

    Long-span precast prestressed hollowcore units place prestressing strand in a thin lower flange where 28-day compressive strength often exceeds C60/75. The fire scenario is dominated by heat exposure to the soffit, and delamination of the lower flange can expose strand to temperatures above 400°C, at which point prestressing steel loses a significant portion of its cold-drawn strength. The addition of 1.5–2.0 kg/m³ monofilament micro-synthetic fiber assists in limiting this delamination by creating vapour-release channels in the dense matrix before pore pressure reaches the spalling threshold. In dry-cast hollowcore production, the mixing regime is shorter and the free-water content is low; fiber must be added to moving aggregate before cement slurry develops, otherwise dry clusters become trapped in the augers of the extruder. Slipform compaction frequency may require a reduced fiber addition at the lower bound of 1.5 kg/m³ where the concrete has a zero-slump consistency. The terminal products, including hollowcore slabs and prestressed beams, are cured on heated long-line beds and then cut to length. Fire testing is typically carried out under ISO 834-1:1999 or EN 1363-1, with acceptance based on maintaining cover to the strand and preventing fire-side spalling that would shorten the load path from strand to bearing.

    Shotcrete Fire Linings for Existing Tunnels and the RWS Thermal Gradient

    Wet-mix shotcrete used for fire protection linings in existing road or rail tunnels is pumped under pressure and sprayed onto rock or secondary lining surfaces. The mix design often specifies C50/60 concrete with silica fume, an alkali-free accelerator, and 2.0 kg/m³ of monofilament micro-synthetic fiber to address spalling under the severe RWS temperature-time curve. The exposed surface receives a near-instantaneous heat flux that creates a steep thermal gradient across the lining thickness. Polypropylene fibers closer to the heated face melt at 160–170°C, but those deeper within the section remain solid until the thermal front advances, which means the vapour-relief network forms progressively rather than simultaneously throughout the full thickness. In shotcrete application, fibre loss through rebound is a recognized uncertainty; the in-place dosage can differ from the batched dosage, and published data for specific in situ fiber retention in micro-synthetic shotcrete is limited. Trial panels should be sprayed, cored and tested for density and void structure. The finished lining may be finished by hand or left as-sprayed. Fire verification follows EN 1363-1 and EN 14488-3, with additional requirements for bond to the substrate under EN 14488-4. The use of alkali-free accelerators does not degrade polypropylene fiber at the dosage relevant to fire protection, but compatibility with air-entraining admixtures and pumping aids must be confirmed in the actual mix because air void spacing factor can shift after long pump campaigns.

    When Hydrocarbon Pool Fires Govern the Design of Industrial Slabs and Secondary Containment

    Industrial slabs exposed to hydrocarbon pool fires present a lower compressive strength class than tunnel linings, but the thermal shock can be severe because a retained pool of burning liquid raises the surface temperature within a very short time. Secondary containment areas in petrochemical plants frequently use C40/50 concrete with a water/cementitious ratio below 0.45, and the slab may be saturated during operational leaks. Sika Fibermesh 150F can be incorporated at 1.5 kg/m³ to create meltable channels that reduce the risk of shallow surface spalling and delamination. The mechanism is the same as in high-strength concrete, but the driving vapour pressure is lower because the matrix is less dense; however, the high moisture content of a wetted slab can offset that difference. The fiber does not affect the cast-in-place finishing of a power-floated industrial floor if added as part of a properly sequenced batch. Hydrocarbon fire testing for such applications may use the hydrocarbon curve in EN 1991-1-2, and the acceptance criterion is usually the absence of progressive spalling at the exposed surface. A limitation is that polypropylene fibers do not improve the abrasion resistance of the finished slab, and their use in secondary containment should be accompanied by verification of crack widths and coating adhesion if a chemical-resistant coating is applied after curing. Because the slab is often unreinforced or lightly reinforced, spalling control also supports the passive fire resistance of supporting steel columns and vessel skirts located within the same pool-fire zone.

    Multi-storey parking structures use C60/75 concrete in double-tee beams, spandrels and load-bearing precast columns. Vehicle fires in open or partially enclosed decks are less severe than hydrocarbon tunnel curves, and the governing fire test is usually the ISO 834-1:1999 cellulosic curve. For this exposure, 1.0–1.5 kg/m³ of monofilament micro-synthetic fiber is generally sufficient to control fire-induced spalling in dense precast elements. The lower bound is preferred where the precast product is extruded on a long-line bed at very low workability, because overdosing increases compaction effort and may create visible fiber clusters at the top surface. In prestressed elements, the fiber addition does not affect strand bond development at this dosage, provided the embedment length and release strength are maintained. The terminal components are then transported and erected as part of a hybrid or all-precast structural frame. Fire acceptance is typically demonstrated on representative deck units, and the limiting criterion is that the vertical deflection of the heated member does not exceed the span/30 limit used in many fire test standards. Where the parking deck is subjected to de-icing salts, the concrete cover and mix design still govern chloride resistance; the fire-protection fiber is not a durability measure under EN 206.

    Spalling Resistance in Cast-in-Place Rail Station Boxes

    Cast-in-place rail station boxes combine thick walls, high-strength concrete and long casting sequences. The structure is often formed in 10–20 m lengths with horizontal construction joints, and the concrete is specified as C70/85 to support soil and rail loads. Fire exposure from a train fire inside the box can follow the RWS or HCM curve depending on the network operator. A 2.0 kg/m³ dose of monofilament micro-synthetic fiber is introduced to limit explosive spalling at the intrados of the roof slab and upper wall sections, where vapour pressure builds behind a dense, heated face. In these sections, reinforcement congestion is high, and concrete placement is performed by boom pump. The fiber addition requires a consistent batching sequence and verification by slump and air content tests before discharge. Because the concrete is exposed to high pumping pressure over distances that may exceed 150 m, the fiber must survive the pump and remain distributed in the placed concrete. Core sampling after construction should include visual inspection for fiber clumping at formwork edges and around embedded conduits, since vibration can locally reorient monofilaments. Fire assessment of rail station boxes is frequently performed on scaled wall and roof panels under EN 1363-1:2020, with additional insulation and integrity limits. The absence of spalling in the test coupon does not automatically prove the in-situ response, because thermal restraint and moisture migration in the full structure are different from an unloaded furnace specimen.

    Normative referenceRelevance in fire-resistant concrete verification
    EN 14889-2:2006Conformity and performance requirements for polymer fibres in concrete
    EN 1992-1-2:2004, Clause 4.5Assessment of spalling in structural concrete under fire
    ISO 834-1:1999Cellulosic temperature-time curve for fire resistance testing
    EN 1363-1:2020General requirements for fire resistance testing
    EN 14488-3Compressive strength testing of sprayed concrete
    EN 12350-7:2019Air content testing of fresh concrete
    ASTM C1116/C1116MReference specification for fibre-reinforced concrete, synthetic fibre classification

    The normative matrix identifies the primary standards used during qualification and production monitoring. Additional requirements from national tunnel authorities, rail operators or fire authorities may impose stricter acceptance limits, and the fire curve selection must be confirmed before the concrete mix is frozen.

    Free Quote

    Competitive Sika Fibermesh 150F - Micro-Synthetic Monofilament Fiber for Resistance to Fire Spalling prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Sika Fibermesh 150F is a micro-synthetic monofilament fibre for concrete that is manufactured from polypropylene and supplied as a collated bundle. The product disperses into discrete filaments under normal concrete mixing and is classified as a Class Ia polymer micro fibre under EN 14889-2:2006 and as a Type III synthetic fibre under ASTM C1116/C1116M. The nominal filament length is 12 mm and the nominal diameter is 18 µm. The specific gravity is 0.91 and the melting point is approximately 160 °C. The as-supplied product is intended for addition at 0.9–1.8 kg/m³ of concrete, with 1.5 kg/m³ commonly specified for fire spalling control in high-strength, low-permeability concrete. The fire-protection function is physical rather than chemical: on heating, the polypropylene filaments melt and leave a network of fine channels in the cement matrix. Those channels create an escape path for water-vapour pressure that would otherwise accumulate in the concrete cover during rapid heating and may initiate explosive spalling.

    How Do 18 µm Monofilaments Modify Vapour Pore Pressure in Dense Concrete?

    Dense concrete mixes with water-cement ratios below 0.40 and especially below 0.35 develop a discontinuous capillary pore structure that restricts moisture movement. During a fire test conducted under ISO 834-1, EN 1363-2, or the RWS curve, the exposed surface heats rapidly and free water near the surface is driven inward. A saturated, low-permeability zone is formed behind the drying front, and the vapour pressure in that zone rises faster than the transport capacity of the pore system. When the pore pressure exceeds the local tensile capacity of the heated concrete, concrete cover can detach explosively.

    Polypropylene monofilament fibre alters this sequence at a temperature threshold of approximately 160 °C. Because the product is supplied with an 18 µm diameter, a given mass produces a very large number of discrete filaments. At 1.5 kg/m³, the nominal filament geometry corresponds to roughly 5.4 × 108 fibres per cubic metre and a cumulative filament length of approximately 6.5 × 106 m per cubic metre. The molten polypropylene is drawn by gas flow into capillary pores and microcracks, where it thermally decomposes and leaves interconnected channels. This channel network increases the effective permeability of the heated concrete and allows vapour pressure to dissipate before the critical tensile stress is reached.

    The mechanism is dosage-dependent and mix-specific. A dosage sufficient for plastic shrinkage crack control may not generate a percolating channel network during fire. Fire spalling control therefore requires dosage verification by furnace testing on the production mix, because aggregate type, moisture condition, specimen thickness, and heating curve influence the result.

    Dosing for Fire Spalling Control Is Not Identical to Plastic Shrinkage Crack Control

    In concrete practice, plastic shrinkage crack control is often targeted with a micro-synthetic fibre dosage of 0.6–0.9 kg/m³. That range is lower than the fire spalling dosage recommended for dense high-strength concrete. The 1.5 kg/m³ addition level increases the number of potential melt channels per unit volume and reduces the average spacing between those channels. At 0.9 kg/m³, the cumulative filament length is proportionally lower, and the probability of a continuous pressure-relief network decreases for the low-permeability pastes most at risk of spalling.

    Batching conditions influence fibre distribution. The fibre should be added to the aggregate stream or to the mixer with sufficient shear to separate the collated bundles. A compulsory pan mixer or a truck mixer at mixing speed is typical; the fibre is not designed for direct hand placement into a low-shear paste. Slump after fibre addition should be measured by ASTM C143/C143M. Workability loss is usually compensated by adjusting a high-range water reducer conforming to ASTM C494/C494M Type F or EN 934-2, not by adding water above the mix design w/c ratio.

    The fibre addition does not alter the hardened compressive strength in a way that should be assumed without testing. Cylinders should be evaluated by ASTM C39/C39M or EN 12390-3. Air content should be monitored by ASTM C231/C231M or EN 12350-7 for mixes requiring freeze-thaw resistance, because fibres are not a substitute for a properly calibrated air-entraining admixture.

    Product data for Sika Fibermesh 150F lists the following typical physical values. The values are nominal and should be confirmed against the current manufacturer’s technical data sheet and project specification before batching.

    Typical product properties for Sika Fibermesh 150F
    PropertyValueReference/Standard
    CompositionMonofilament polypropyleneManufacturer data sheet
    Nominal diameter18 µmEN 14889-2:2006 Class Ia diameter threshold
    Nominal length12 mmManufacturer data sheet
    Specific gravity0.91Manufacturer data sheet
    Melting point160 °CManufacturer data sheet
    Water absorptionNilManufacturer data sheet
    ClassificationClass Ia synthetic micro fibre / Type IIIEN 14889-2:2006 / ASTM C1116/C1116M
    Fire spalling dosage1.5 kg/m³ initial targetProject-specific fire test recommended

    Compliance with EN 14889-2:2006 for Class Ia polymer fibres requires third-party evaluation of factory production control under the applicable attestation system. The classification does not by itself establish a fire rating or a minimum post-crack residual strength. Fire behaviour must be established through project-specific furnace testing.

    When the Specification Requires ASTM C1116/C1116M Type III and EN 14889-2 Class Ia

    Under ASTM C1116/C1116M, Type III denotes synthetic fibre reinforcement. The designation separates synthetic fibres from Type I steel, Type II glass, and Type IV natural fibres. Under EN 14889-2:2006, Class Ia denotes polymer micro fibres with a diameter below 0.3 mm. The 18 µm diameter of Sika Fibermesh 150F places it within that Class Ia category.

    These classifications describe material origin and geometric class; they do not quantify fire spalling resistance. A specification that names Type III or Class Ia is therefore a starting point for material acceptance, not a substitute for a fire test under EN 1363-2, ISO 834-1, or a project-specific RWS curve. This distinction is important in tunnel, car park, and precast structural applications where the failure mode is explosive spalling rather than general structural collapse.

    Product conformity should also be checked against the national annex or project-specific requirements for concrete constituents. The product is not classified as a reinforcement bar replacement and should not be counted toward minimum reinforcement ratios in structural design using EN 1992-1-1 or ACI 318 unless explicitly permitted by the design code.

    Micro-Monofilament Geometry Versus Steel and Macro-Synthetic Fibres

    Steel fibres conforming to EN 14889-1 are typically specified at 20–60 kg/m³ and provide post-crack flexural performance measured by EN 14651 or ASTM C1609/C1609M. Their larger diameter and higher density reduce the number of discrete filaments per unit mass. Steel fibres do not melt at the temperatures associated with early fire exposure, and their primary function is load transfer across cracks rather than vapour pressure relief. The presence of steel fibres may be beneficial for structural residual capacity, but it does not necessarily provide the pore-pressure relief required to prevent spalling in high-strength concrete.

    Macro-synthetic fibres conforming to EN 14889-2:2006 Class II have diameters above 0.3 mm and are used at 3–9 kg/m³ for toughness and corrosion-resistant reinforcement. They also melt under heat, but at equal mass addition the number of fibres per cubic metre is much lower than for an 18 µm monofilament. A macro-synthetic fibre designed for post-crack performance is therefore not a direct substitute for a micro-synthetic fire spalling fibre unless the specific product has been tested for that application.

    Typical fibre class comparison for concrete
    ParameterSika Fibermesh 150FSteel fibre EN 14889-1Macro-synthetic fibre EN 14889-2 Class II
    Diameter18 µm0.5–1.0 mm0.3–1.2 mm
    Length12 mm30–60 mm30–65 mm
    Density0.91 g/cm³7.85 g/cm³0.90–0.95 g/cm³
    Typical dosage0.9–1.8 kg/m³20–60 kg/m³3–9 kg/m³
    Primary mechanical rolePlastic crack control and fire spalling vapour reliefPost-crack flexural toughnessPost-crack toughness with corrosion resistance
    Fire spalling vapour reliefHigh filament count; melts at 160 °CLow specific surface area; remains solid at typical spalling temperaturesMelts but lower filament count at equal mass

    The comparative table is derived from typical classification ranges in EN 14889-1 and EN 14889-2:2006 and from the product data sheet values for Sika Fibermesh 150F. Project-specific values should be verified with the fibre manufacturer and the concrete producer.

    What Operational Boundaries Apply to Batching and Overdosing?

    The recommended upper addition for Sika Fibermesh 150F is 1.8 kg/m³. Exceeding this limit increases the probability of fibre balling, uneven distribution, and workability reduction, particularly in mixes with cementitious contents below 350 kg/m³ or paste volumes below 25 % by volume. In such mixes, the fibre should be introduced in stages and the concrete should be monitored visually during discharge for undispersed bundles. If persistent balling occurs, adjustment of mixing sequence, addition rate, or admixture package is required before increasing dosage.

    The product does not eliminate the need for standard curing. Curing compound or wet curing under ASTM C171 or EN 13670 remains necessary for strength development and surface quality. It is not an air-entraining agent and should not be used to meet freeze-thaw durability requirements unless the concrete has an independently verified air-void system tested by ASTM C457/C457M. The fibre is not a corrosion inhibitor, and it does not reduce chloride ingress in the same manner as a low-clinker or supplementary-cementitious mix design.

    Project-specific fire testing remains the controlling verification for spalling resistance. Published data for this specific configuration is limited, and the fire performance of a concrete member depends on aggregate type, moisture content, loading, and thermal restraint. A furnace test using the specified fire curve and a sample representative of production concrete is the accepted method for confirming that a 1.5 kg/m³ dosage produces the required pressure-relief behaviour.