Liwei Group Co., Ltd

Products

SikaFiber 106 - Fine Monofilament Polypropylene Fiber

    • Product Name: SikaFiber 106 - Fine Monofilament Polypropylene Fiber
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 691205
    Material 100% polypropylene
    Fibertype Fine monofilament
    Color Natural
    Length 6 mm
    Diameter 0.02 mm
    Aspectratio 300
    Density 0.91 g/cm3
    Tensilestrength 350 MPa
    Elasticmodulus 3500 MPa
    Meltingpoint 160-170 C
    Alkaliresistance Excellent
    Waterabsorption Nil

    As an accredited SikaFiber 106 - Fine Monofilament Polypropylene Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SikaFiber 106 is supplied in 600 g polyethylene bags, with 20 bags per carton (12 kg total).
    Container Loading (20′ FCL) Container Loading (20′ FCL): Palletized SikaFiber 106 fine monofilament polypropylene fiber, stowed securely in a dry, ambient container for compliant transport.
    Shipping SikaFiber 106 – Fine Monofilament Polypropylene Fiber is a non-hazardous, non-regulated solid. It is supplied in sealed moisture-resistant bags, typically palletized and shrink-wrapped. Transport in dry, covered vehicles; avoid punctures, moisture, and prolonged sunlight. No special transport labels or dangerous goods documentation are required.
    Storage Store SikaFiber 106 in a cool, dry, well-ventilated area, away from direct sunlight and moisture. Keep original bags sealed, on pallets, off the ground. Protect from contamination, oils, chemicals, and excessive heat. Avoid open flames. Do not stack excessively high. Use oldest stock first. Under proper storage, shelf life is typically 24 months.
    Shelf Life Shelf life is 24 months from production when stored dry in unopened original packaging, protected from moisture and direct sunlight.
    Application of SikaFiber 106 - Fine Monofilament Polypropylene Fiber

    In bonded cementitious screed underlayments specified for renovation over hydronic heating circuits, plastic shrinkage cracking initiates when the surface evaporation rate exceeds the bleed water supply rate under forced-air curing conditions. SikaFiber 106, a fine monofilament polypropylene fiber, is introduced at 0.6–0.9 kg/m³ of fresh mortar to provide a distributed crack-bridging network during the first 6–8 h after placement. The hydrophobic monofilament does not absorb mix water; tensile strength for this fiber class typically lies in the 300–400 MPa range with an elastic modulus below 5 GPa, producing a low modulus mismatch against fresh cement paste but no structural post-cracking capacity. Compliance for CE-marked screeds requires the fiber to meet EN 14889-2:2006 polymer microfibre requirements and the finished screed to conform to EN 13813:2002, while North American specifications reference ASTM C1116/C1116-23 Type III synthetic fiber-reinforced concrete. Plastic shrinkage evaluation uses ASTM C1579-21 restrained slab testing; acceptance commonly requires crack width reduction below 0.5 mm at the specified dosage relative to an unreinforced reference of equivalent water-to-binder ratio.

    Standard designationParameterAcceptance criterion
    EN 14889-2:2006Polymer microfibre conformityClass I
    EN 13813:2002Screed material requirementproject-specified compressive class
    ASTM C1579-21Restrained plastic shrinkage crack width≤ 0.5 mm
    ASTM C1116/C1116-23Synthetic fiber-reinforced concrete typeType III

    Production-scale dry-mix plants add the fiber after fine aggregate drying and before cement is charged into a twin-shaft paddle mixer, avoiding direct contact with the high-speed disperser. Dry mixing of 60–90 s at rotor speeds between 25–40 rpm disperses the monofilament bundles, but plant trials show that wet mixing times below 120 s in a continuous rotor/stator mortar pump can leave visible fiber agglomerates in the first 15% of the discharge when dosage exceeds 0.9 kg/m³. The difficulty arises from electrostatic clumping of fine polypropylene filaments during pneumatic conveying into the silo; maintaining storage humidity below 60% RH and grounding the dosing lance reduces this. In the field, addition water is dosed to achieve a flow spread between 220 mm and 260 mm under EN 12706:2019; dosage above 1.0 kg/m³ typically reduces spread by 10–15 mm, requiring the addition of a high-range water reducer at 0.1–0.2% by binder mass to restore pumping viscosity. Air content is verified by EN 1015-7; values above 3.0% and pump dead-heading longer than 10 min are associated with cavitation and nonuniform fiber distribution. Terminal product types include pumpable self-leveling underlayments and bonded hydraulic screeds with nominal thickness from 5 mm to 30 mm.

    What Restricts Early-Age Crack Formation in Thin-Bonded Facade Renders Exposed to High Solar Gains?

    Exterior polymer-modified base coats with a nominal thickness between 4 mm and 8 mm develop rapid moisture loss at the exposed surface when south-facing facade temperatures exceed 50°C before initial set. In this configuration, SikaFiber 106 is dry-blended at 0.3–0.6 kg/m³ of wet render to reduce plastic cracking along the embedded glass-fibre mesh edge and around insulation board joints. The responsible mechanism is crack-bridging by monofilament pull-out within the first 3–5 h, before the polymer-modified phase forms a continuous film. The render must conform to EN 998-1:2016 rendering mortar categories, while the fiber component is covered by EN 14889-2:2006 and the external thermal insulation composite system by the relevant European Assessment Document, typically EAD 040083-00-0404. Contract specifications often require plastic shrinkage crack resistance to be evaluated under ASTM C1579-21 at the same dosage and substrate configuration, with no visible crack wider than 0.2 mm under 6 h of 40°C fan-assisted drying. At dosages above 0.6 kg/m³, spray-applied base coats through a worm pump with a 6 mm nozzle show increased pumping pressure and rebound loss; the addition rate is therefore capped at 0.6 kg/m³ unless a paddle mixer with 3 min wet mixing and a larger 8 mm nozzle are used. The terminal product type is a thin-bed EIFS base coat, glass-fibre mesh-embedded decorative render, or crack-bridge coating over rigid insulation boards. The fiber does not replace alkali-resistant glass mesh or movement joints, and cracking caused by structural movement falls outside the product’s function.

    Where thin-bed tile adhesive mortars are specified as C2TE classified systems under EN 12004-1:2017, the addition of a fine monofilament polypropylene fiber alters the fresh-mortar stress history during the initial 24 h of drying. In this application, the dosage is typically 0.1–0.3% by dry mortar mass, corresponding to approximately 0.05–0.15 kg/m³ for a 4 mm notched trowel coverage. The fiber functions by reducing plastic shrinkage crack formation at tile corners and around floor drains where local film thickness fluctuates; it does not contribute to the tensile adhesion strength classification. Compliance is established through EN 12004-1:2017 for adhesive performance, ISO 13007-1 for the system standard, and EN 14889-2:2006 for the polypropylene fiber itself. Production dry-mix facilities disperse the fiber in a horizontal ribbon blender using a pre-mix of sand and cement before adding redispersible polymer powder; batch records show that dumping all components simultaneously with fiber at the top creates a fines-rich upper layer that does not discharge uniformly into valve bags. Terminal products include polymer-modified thin-bed adhesives for porcelain and low-absorption stone tiles, and low-dosage grout formulations at 0.03–0.08% by mass where surface fiber protrusion would otherwise create a tactile defect.

    Repair Mortar Performance Under Volume-Restrained Overlay Conditions

    Structural repair mortars placed in thicknesses between 10 mm and 50 mm over prepared concrete substrates develop edge restraint from the old concrete, generating tensile strain in the overlay while its pore water is still thermodynamically available to evaporate. SikaFiber 106 is batched at 0.5–1.0 kg/m³ of wet repair mortar to suppress early-age microcracking before the development of sufficient tensile strength for the repair system to accommodate restrained shrinkage. The fiber is a polymer microfibre under EN 14889-2:2006, and the mortar must comply with EN 1504-3:2005, with structural overlay products typically tested as class R4 for compressive strength, chloride ion migration, and bond strength by pull-off. In North America, packaged repair materials may be specified under ASTM C928/C928M-20; plastic shrinkage performance is assessed by ASTM C1579-21. The production process for dry-mix repair mortar uses a pan mixer with a paddle speed below 30 rpm to avoid damaging the fine monofilament, because high-speed dispersion can bend and wrap fibers around the paddle shaft, forming clusters that survive re-mixing on site. The operational boundary at the jobsite is the wet mixing time: less than 2 min of mixing in a handheld paddle drill at 400–600 rpm gives nonuniform fiber distribution; more than 4 min entrains air and accelerates surface skin formation, particularly when ambient temperature exceeds 30°C. Terminal product types include vertical and overhead structural repair mortars, non-structural skim coats, and form-and-pour repair concrete for edge spalls. The fiber is not a substitute for structural reinforcement, load-transfer dowels, or movement joints.

    When Fresh Shotcrete Lining Undergoes Early-Age Tunnel Ventilation

    In underground works, wet-mix shotcrete placed as an initial lining can be exposed to ventilation air velocities above 2 m/s within 30 min of spraying, removing the water film that normally suppresses plastic shrinkage at the sprayed surface. Under these conditions, SikaFiber 106 is added at 0.6–0.9 kg/m³ of concrete to reduce the width and connectivity of early-age cracks around rock bolts and steel arch ribs. The relevant process standard for sprayed concrete is EN 14487-1:2005 in European practice, with ACI 506R-16 used for guidance in North America; the polypropylene fiber is specified to EN 14889-2:2006, and hardened concrete quality is verified by EN 14488-2 compressive strength cores or beams according to EN 14488-3. The addition rate is limited in wet-mix shotcrete because fine monofilament fibers increase the viscosity of the pumped concrete at the nozzle; spraying trials show that when dosage exceeds 1.0 kg/m³, the pump stroke rate must be reduced by up to 12% to avoid blockages in the 50 mm delivery line, and rebound can increase from 10% to 18% in overhead zones. The terminal product type is a fibre-reinforced shotcrete lining for temporary and permanent underground support; however, the fine monofilament does not provide post-crack energy absorption equivalent to steel or polymer macrofibers, and high-deformation zones require a separate macrofiber verification under EN 14488-5 or ASTM C1550.

    Simultaneously applied as a two-coat flexible cementitious membrane under bonded ceramic tiles, the wet slurry undergoes rapid capillary drainage into porous substrates, producing shrinkage tensile stress at membrane thickness transitions around pipe penetrations and wall-floor junctions. In this application, SikaFiber 106 is dry-blended at 0.1–0.3% by powder mass to reduce microcracking in the 1–2 mm cured film without reducing water impermeability. The membrane system is tested under EN 14891:2017 for liquid-applied water impermeable products beneath ceramic tiling, including watertightness under positive pressure, crack-bridging ability, and bond strength after water immersion and thermal ageing; the fiber component is covered by EN 14889-2:2006. Production mixing uses a low-shear planetary mixer to avoid entraining air; the powder is gradually introduced into water over 60–90 s while the mixer operates at 100–300 rpm, then mixed for a further 2 min to wet out the hydrophobic monofilament surface. Field application uses a notched trowel or brush for the first coat, followed by a second coat after 4–6 h; membrane thickness is wet-checked with a comb gauge to maintain 0.8–1.5 mm per coat. The terminal product type is a flexible cementitious waterproofing membrane for wet rooms, balconies, and foundation planter walls where the membrane remains unbonded at movement joints. Dosages above 0.3% are not recommended in this configuration because fiber accumulation at the squeegee edge can leave visible surface streaks in the cured membrane.

    Free Quote

    Competitive SikaFiber 106 - Fine Monofilament Polypropylene Fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Classified as a fine monofilament polypropylene fiber for secondary reinforcement, SikaFiber 106 is specified in concrete and cementitious mortars where control of plastic shrinkage cracking, plastic settlement cracking, and early-age surface tearing is required. The product is not intended to replace primary steel reinforcement in structural design. The fiber is supplied as discrete collated monofilaments; during mixing, the collated bundles separate into individual filaments with a nominal length of 12 mm and a nominal diameter of 31 µm. Material classification places the fiber within ASTM C1116/C1116M-10a Type III synthetic fiber-reinforced concrete, subject to the specification’s testing and acceptance limits.

    The polymer matrix is polypropylene with a published specific gravity of 0.91, a melt point near 160 °C, and negligible water absorption. Individual filament tensile strength is typically reported in the range of 300–500 MPa, with an elastic modulus of approximately 3.5 GPa. Because the fiber is hydrophobic and non-corroding, it does not introduce the chloride-induced corrosion mechanisms associated with steel fiber surfaces. The fine diameter produces a high filament count per unit mass; at 0.9 kg/m³, the theoretical count is approximately 1.1 × 10^8 filaments per cubic metre when calculated from the nominal geometry and density.

    What Physical Parameters Separate SikaFiber 106 from Fibrillated or Macro-Synthetic Reinforcement?

    The controlling parameters are fiber material, monofilament diameter, length, density, tensile strength, elastic modulus, melt temperature, and alkali resistance. Unlike fibrillated polypropylene fibers, which are formed from a film that delaminates into interconnected fibrils during mixing, the monofilament geometry has a defined circular cross-section. This geometry reduces fiber-ball formation, but crack bridging in the hardened state remains limited by the low modulus of polypropylene relative to concrete. The fiber is therefore categorized as a microfiber for plastic-state crack control rather than as a macro-synthetic structural fiber.

    Parameter Test method or standard Typical value or specification limit
    Fiber classification ASTM C1116/C1116M-10a Type III synthetic fiber-reinforced concrete
    Nominal filament length Supplier specification 12 mm
    Nominal filament diameter Supplier specification 31 µm
    Specific gravity Supplier specification 0.91
    Tensile strength Supplier specification 300–500 MPa
    Tensile modulus Supplier specification 3.5 GPa
    Melt point Supplier specification 160 °C
    Water absorption Supplier specification <0.1% by mass
    Nominal dosage for plastic shrinkage control Supplier specification 0.9 kg/m³
    Package mass Supplier specification 0.9 kg per bag

    The plastic shrinkage control mechanism is governed by the fiber’s ability to limit capillary pressure build-up and intercept microcracks during the first 6–12 hours after concrete placement. In slab-on-grade applications, water evaporation from the surface exceeds bleed water supply when the evaporation rate approaches 1.0 kg/m²/h, commonly at ambient air velocities above 4–5 m/s or concrete temperatures above 35 °C. The distributed monofilament phase increases the tensile strain capacity of fresh paste by bridging developing fissures before they coalesce into visible surface cracks. A dosage of 0.9 kg/m³ is the nominal target for plastic shrinkage control; reductions to 0.6 kg/m³ may be acceptable for non-critical interior slabs, but published data for this specific configuration under ASTM C1579-21 is limited when the water-cement ratio exceeds 0.50.

    Based on nominal geometry, the theoretical volume fraction at 0.9 kg/m³ is approximately 0.099% by volume. A simple cubic distribution yields a mean center-to-center filament spacing near 2.1 mm. This spacing is not a design value for structural capacity; it is a geometric description of the dispersed phase relevant to early-age microcrack interception. At water-cement ratios below 0.42, the fine monofilament phase produces a lower viscosity increase than fibrillated polypropylene of the same mass because the opened fibril network has a larger specific surface area and greater mechanical interlock with aggregate particles.

    Slab-on-Grade Placement and Early-Age Crack Control

    The product is specified in slab-on-grade, composite metal deck slabs, precast panels, shotcrete, and thin-section repairs. In slab-on-grade work, the primary objective is to limit early-age surface cracking before final set, with crack measurements made according to ASTM C1579-21 or equivalent project-specific methods. Fiber effectiveness is influenced by concrete cover, surface finishing operations, and curing. Power trowel finishes may produce surface fuzz if filaments are exposed during the first pass; a low-speed walk-behind trowel with pan floats is typically specified until the surface paste has closed over the fibers. Hard-troweled surfaces may require a final steel-blade pass only after the polypropylene filaments have been fully encapsulated by cement hydrate. Immediate steel troweling can drag filaments and create visible surface defects.

    Air-entrained concrete accepted under ASTM C231/C231M remains compatible with monofilament polypropylene fibers because the fibers do not themselves stabilize air voids. However, the combined effect of high-range water-reducing admixtures and elevated fiber content can reduce slump and lower surface bleed. In placements where slump is held at 150 mm or greater, the fiber dosage should be verified in a field trial rather than extrapolated from plain concrete batch records. Hot-weather placement risk should be assessed using ACI 305R-20, and fogging or evaporation retarders may still be required at the surface because the fiber does not eliminate evaporation.

    In precast panel production, the fiber is added to control plastic shrinkage cracking between casting and demolding. It does not replace edge lifting anchors, welded reinforcement, or minimum concrete cover requirements. The mix should be adjusted using the same water-cement ratio as the approved non-fiber reference mix; additional water should not be introduced solely to compensate for fiber-induced workability loss. If the fiber is added to self-consolidating concrete, the rheology should be checked with a slump-flow test and visual stability index before placement.

    When Fibrillated, Macro-Synthetic, or Steel Fibers Are Not Direct Replacements

    A direct substitution of SikaFiber 106 for steel fibers, macro-synthetic fibers, or fibrillated polypropylene fibers is technically invalid unless the specified performance parameter is limited to plastic shrinkage crack control. Steel fibers are governed by ASTM A820/A820M, and macro-synthetic fibers are commonly addressed under ASTM C1116/C1116M or EN 14889-2:2006 for polymer fiber applications. These products are typically added at 15–50 kg/m³ or higher to produce post-crack residual flexural strength under ASTM C1609/C1609M. SikaFiber 106 at 0.9 kg/m³ does not produce equivalent residual strength because the low modulus and short length limit pullout resistance once crack widths exceed the filament bond region.

    Fibrillated polypropylene fibers may be used at comparable 0.9 kg/m³ dosage, but their film-network morphology creates a different rheological response. The fibrillated structure tends to reduce slump more than monofilaments of equivalent mass because the opened fibril network increases specific surface area and mechanical interlock. Field comparisons in slab placements show that fibrillated fibers, when added to mixes with a water-cement ratio below 0.42, can produce a greater viscosity shift than fine monofilaments. This shift can force water additions that violate the approved mix design. SikaFiber 106 is selected where fiber distribution and lower slump loss are the controlling placement parameters; it is not selected where hardened-state toughness or structural post-crack load capacity is required.

    Fiber class Typical dosage Governing standard Primary performance Workability impact
    Fine monofilament polypropylene, SikaFiber 106 0.6–0.9 kg/m³ ASTM C1116/C1116M Type III Plastic shrinkage crack control Lower measured slump reduction than fibrillated fibers
    Fibrillated polypropylene 0.9 kg/m³ ASTM C1116/C1116M Type III Plastic shrinkage crack control Moderate slump reduction, viscosity increase
    Macro-synthetic polymer 3–9 kg/m³ EN 14889-2:2006, ASTM C1116/C1116M Post-crack residual strength in slabs, shotcrete Dosage-dependent, pumping requires verification
    Steel fiber 20–50 kg/m³ ASTM A820/A820M Post-crack flexural toughness, structural replacement in certain designs Low, but batching and pumping demands increase

    Addition rates above 1.0 kg/m³ can produce visible surface fuzz and finishing delays in thin toppings; rates below 0.4 kg/m³ may not provide a sufficient filament count to intersect early-age microcracks. Polypropylene begins to soften near 160 °C, so SikaFiber 106 should not be specified as continuous-service reinforcement where the concrete section is exposed to temperatures above that limit. The fiber itself is alkali-insensitive and does not require pre-drying at relative humidity above 60%; however, storage in wet environments can degrade the bag and should be avoided.

    At the mixer, the fiber should be added after the aggregate and cement charge to prevent the low-density filaments from stratifying above mineral components. In mobile volumetric mixers and central batch plants, placing bags on the aggregate conveyor can create intermittent clumping because polypropylene filaments electrostatically attach to dry aggregate surfaces. Production-scale observations indicate that direct addition into the mixing screw at the slump-adjustment stage reduces batch-to-batch variance when the mixer speed produces a falling curtain of material rather than a low-shear tumbling profile. In high-shear pan mixers with tip speeds above 3 m/s, batch times should be validated because hydrophobic filaments can adhere to mixer blades through triboelectric charging. Adding the fiber after initial water addition reduces this static build-up. The product should not be dry-blended with steel fibers before charging because density disparity produces segregation; in hybrid systems, the micro polypropylene component should be added first after the aggregate charge and allowed to disperse before steel fiber addition.

    For European applications, documentation should confirm compliance with REACH Regulation (EC) No 1907/2006 and RoHS Directive 2011/65/EU, because polypropylene fibers are treated as articles under those frameworks. Final responsibility for suitability rests with the project engineer and concrete producer, based on trial batches, approved mix design, and the governing reinforced concrete code for the member type.