| HS Code | 770910 |
| Product Name | SikaFiber 20 PPM PH - Monofilament Polypropylene Microfiber |
| Material | Polypropylene |
| Fiber Type | Monofilament |
| Form | Monofilament fibers |
| Color | Natural |
| Length | 20 mm |
| Diameter | 0.02 mm |
| Aspect Ratio | 1000 |
| Density | 0.91 g/cm³ |
| Tensile Strength | 400 MPa |
| Elastic Modulus | 3500 MPa |
| Elongation At Break | 20% |
| Melting Point | 160 °C |
| Ignition Point | >350 °C |
| Water Absorption | Nil |
| Alkali Resistance | Excellent |
| Acid Resistance | Excellent |
| Salt Resistance | Excellent |
| Chemical Inertness | High |
| Corrosion Resistance | High |
| Magnetic | No |
| Thermal Conductivity | Low |
| Electrical Conductivity | Low |
| Dosage | 0.9 kg/m³ |
| Packaging | 1 kg bag / 20 kg box |
| Storage | Dry conditions |
| Shelf Life | 5 years |
| Plastic Shrinkage Cracking | Reduces |
| Impact Resistance | Improves |
| Freeze Thaw Durability | Improves |
| Permeability | Reduces |
As an accredited SikaFiber 20 PPM PH - Monofilament Polypropylene Microfiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber 20 PPM PH comes in 0.9 kg (2 lb) water-soluble bags, packaged 24 bags per carton for concrete mixing. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): SikaFiber 20 PPM PH monofilament polypropylene microfibers are palletized, shrink-wrapped, and securely loaded for shipment. |
| Shipping | SikaFiber 20 PPM PH is non-hazardous and not classified as dangerous goods for transport. Ship as general cargo in original, sealed, labeled packaging on pallets. Protect from moisture, contamination, and punctures; keep dry and avoid extreme heat. No special ventilation, segregation, or emergency measures required. Follow local regulations. |
| Storage | Store SikaFiber 20 PPM PH in a cool, dry, well-ventilated area, away from direct sunlight, moisture, open flames, and strong chemicals. Keep in original unopened packaging on pallets off the ground. Protect from contamination and excessive heat. Seal partially used bags to prevent moisture ingress. Typical shelf life is 24 months when stored properly; follow local regulations and the SDS. |
| Shelf Life | Shelf life is 24 months from production if stored in unopened, undamaged original packaging, dry, away from direct sunlight. |
The production of precast architectural cladding panels and buried utility structures using SikaFiber 20 PPM PH is directed at early-age moisture-loss crack suppression across forms with high surface-to-volume ratios, where conventional welded wire reinforcement cannot intercept every sub-millimetre crack before it reaches the demolded face. The fibre is regulated under ASTM C1116/C1116M-23 Type III fibre-reinforced concrete, EN 14889-2:2006 Class I polymer fibres with CE marking under Annex ZA, and PCI MNL 116-21 for architectural precast production. Addition ratio is specified between 0.6 kg/m³ and 1.2 kg/m³, with 0.9 kg/m³ adopted as the default for panels thinner than 150 mm demolded at 16–24 h. Higher dosages are not automatically superior; they are restricted to sections with exposed aggregate finishes or water-cementitious ratios below 0.40 where paste distribution is non-uniform. The addition ratio does not modify panel lifting stresses calculated under PCI MNL 116-21, and the fibre does not replace primary flexural reinforcement.
Production-scale batching of architectural precast containing SikaFiber 20 PPM PH typically begins in a twin-shaft compulsory mixer with dry aggregate and fibre blended for 30–45 s before water and superplasticizer are introduced. Post-water addition in pan mixers with worn blades has produced monofilament agglomerations at aggregate moisture contents above 4%; therefore the fibre is added to the dry aggregate stream or the mixing time is extended by 45 s when the batching sequence cannot be changed. Vibratory feeders discharging at 0.5–1.0 kg/min reduce bridging across the hopper gate, while diaphragm feeders have shown greater batch-to-batch variation in fibre feed mass. After water and polycarboxylate ether superplasticizer are introduced at 0.4–0.8% by cement mass, slump is maintained between 100 mm and 150 mm. Lower slumps below 80 mm have caused incomplete monofilament wetting in mixes containing silica fume above 5%. Mold filling uses external electric or pneumatic vibrators operating at 45–65 Hz; vibration is applied in 10–20 s intervals per lift because low-density polypropylene fibre can migrate toward the exposed face when vibration exceeds 90 s per lift. Curing is initiated at initial set with ASTM C309-complying membrane-forming compounds or steam curing at 60–70°C for 8–12 h. Stripping is permitted only after the element reaches the minimum compressive strength required by the lifting design, typically 15 MPa for non-prestressed architectural panels.
Terminal finished product types include insulated sandwich wall panels, exposed aggregate spandrel panels, cast stone cladding, transformer vaults, catch basins, and prefabricated utility boxes. In all cases the microfibre is limited to reducing plastic shrinkage crack formation; hardened drying shrinkage and service-load crack width are addressed by primary reinforcement, concrete cover, and joint layout.
In tunnel advance sections and rock slope stabilization works, SikaFiber 20 PPM PH is metered into wet-mix shotcrete at the batch plant rather than at the nozzle to avoid strand separation in the high-shear pneumatic stream. The applicable compliance framework consists of ACI 506R-21 for wet-mix shotcrete practice, EN 14487-1:2005 for sprayed concrete specification, EFNARC 1996 for European shotcrete construction, and ASTM C1436-13 for shotcrete materials. Addition ratio is set between 1.0 kg/m³ and 2.0 kg/m³; the lower end is retained for continuous concrete pumps with 50–65 mm hoses and the upper end for dry-weather slope work where evaporation exceeds 1.2 kg/m²/h. Above 2.0 kg/m³, pump cylinder packing has been observed on site when the aggregate packing is dense and paste volume falls below 330 L/m³. Published retention data for this specific fibre product in high-volume wet-mix operations with variable aggregate moisture is limited, so acceptance trials at the batching plant are required when aggregate source or accelerator supplier changes.
The downstream production process starts in a twin-shaft batch plant or ready-mix truck drum rotating at 8–12 rpm. The fibre is added to the aggregate stream before water; the mixing time after water addition is extended to 90–120 s to separate monofilaments in mixes containing polycarboxylate ether superplasticizer at 0.6–1.2% by cement mass. Slump at the nozzle is controlled at 140–180 mm. Wet-mix is delivered through a piston pump at 30–55 bar outlet pressure and a 50–65 mm hose; compressed air is injected at 5–8 m³/min at the nozzle to project the mix at a 1.0–1.5 m stand-off distance. Alkali-free accelerators are metered at 3–6% by cement mass; higher dosages have produced flash set at the nozzle and embedded fibre clumps in rebound. Rebound rates in open slope work typically remain between 10% and 25%, and rebound aggregate is not reintroduced into the mix because the fibre distribution in rebound is not representative of the in-place lining. The nozzle operator controls the build thickness in 20–30 mm passes, with each pass allowed to reach initial set before the next pass is applied.
| Standard designation | Scope | Control parameter |
|---|---|---|
| ACI 506R-21 | Wet-mix shotcrete guide | Pump line pressure and nozzle distance |
| EN 14487-1:2005 | Sprayed concrete performance classes | Compressive strength and energy absorption |
| EFNARC 1996 | European shotcrete specification | Workability and accelerator dosage |
| ASTM C1436-13 | Materials for shotcrete | Fibre product type and dosage |
Terminal finished product types include permanent rock support linings, prefabricated tunnel lining shells, cut-and-cover headwalls, and erosion-resistant channel linings. The fibre does not replace welded wire mesh or structural macrofibre where flexural toughness and post-crack residual strength are specified under EN 14488-3.
Laser-screened warehouse slabs and external hardstandings that cannot be wet-cured before the first finishing pass are one application where SikaFiber 20 PPM PH alters the early-age bleed profile and reduces the incidence of mapped surface crazing. In this production setting the relevant standards are ACI 302.1R-15 for floor slab construction, ASTM C1581/C1581M-18a for restrained shrinkage cracking resistance, ASTM C94/C94M-24 for ready-mix batching, and TR34:2013 for industrial concrete ground floors. The formulation addition ratio is held between 0.9 kg/m³ and 1.8 kg/m³, with the upper limit selected only when the slab is placed under forced-air heaters, wind speeds above 15 km/h, or when the water-cementitious ratio is below 0.42. At addition rates above 1.5 kg/m³, ride-on power trowel operators have observed fibre fuzzing on burnished surfaces when the finishing pass begins before the bleed-water sheen has completely disappeared.
Downstream placement is carried out by truck-pour or pump through 100–125 mm pipeline into laser-screeded strips. The screed is set to a profile tolerance of ±5 mm under a 3 m straightedge. Initial bull-floating is followed by pan floating and then power trowel blades at increasing angles; blade pitch is limited to 10–15° during the first two passes to avoid tearing the fibre-rich paste. Because polypropylene monofilament reduces bleed-water migration to the surface, the interval between screeding and the first trowel pass is extended by 30–60 min relative to plain concrete at the same slump; if the sheen is trapped under a hardened surface, delamination occurs. Curing compounds complying with ASTM C309 are applied at 200–250 g/m² after final finishing; wet curing with saturated geotextile is used where environmental conditions drop below 10°C or relative humidity falls below 40%. Saw-cut contraction joints are executed at 6–12 h after final finish, depending on blade aggregate exposure limits and the early-age compressive strength, but the fibre does not alter joint spacing derived from design charts.
Terminal finished product types include high-bay distribution center slabs, automated storage and retrieval system floors with superflat profiles, bus and truck hardstandings, parking deck slab toppings, and cold-store floors. The microfibre is not used to replace either saw-cut contraction joints or slab reinforcing steel, and joint spacing remains governed by ACI 302.1R-15 and TR34:2013.
Pre-bagged concrete repair mortars and site-mixed structural patching compounds receive SikaFiber 20 PPM PH only after the bid specification identifies restrained shrinkage at the substrate interface as the governing failure mode. The compliance envelope for this application is derived from EN 1504-3:2005 for structural and non-structural repair products, with class R3 or R4 compressive strength requirements, ASTM C928/C928M-20a for packaged rapid-hardening cementitious materials, and ACI 546.3R-14 for fiber-reinforced repair materials. Addition ratio is 0.5–1.0 kg/m³ when mixed as a wet repair mortar, or 0.1–0.3% by total dry powder mass in factory-bagged products. Above 0.3%, the wet density decreases and the filled mortar may fall below the 2,000 kg/m³ lower bound expected for some R3 formulations; below 0.1%, plastic shrinkage crack reduction is negligible in a restrained overlay under EN 1504-3 testing.
Production and placement involve abrasive blast removal of unsound substrate to an ICRI surface profile of CSP 6 to CSP 9, followed by saturated-surface-dry conditioning for 24 h before bonding. A cementitious bonding slurry at 0.5–1.5 mm thickness is applied, then the repair mortar is mixed in a forced-action paddle mixer at 20–30 rpm for 180–240 s; the pot life is maintained between 30 min and 60 min at 20°C. Application thickness is limited to 10–50 mm per layer; if the section exceeds 50 mm, a polymer-modified leveling layer or coarse aggregate extension is used. Overhead and vertical patches are applied with hand pressure and finished with a wooden float only after initial set begins; early steel troweling is avoided because it can drag fibre to the surface and close bleed channels before water has evaporated.
Terminal finished products include bridge deck spall patches, balcony edge repairs, industrial floor patch compounds, marine pile jacket repairs, and precast element spall infill. The fibre is not considered primary reinforcement in any structural repair, and if the design requires post-crack residual strength, macrofibre or steel reinforcement must be provided separately under EN 1504-3.
Spray-applied cementitious render and one-coat facade plaster receive SikaFiber 20 PPM PH to reduce slip at vertical build thickness and to control plastic shrinkage cracking caused by substrate suction, particularly on low-absorption masonry units. The application standard set comprises EN 998-1:2016 for rendering and plastering mortar properties, EN 13914-2:2016 for external rendering workmanship, ASTM C926-20 for portland cement plaster application, and ASTM C1063-20 for lath and furring where applicable. The addition ratio is between 0.06% and 0.15% by dry-mix mass; the upper limit of 0.2% is considered the practical ceiling because higher fibre concentrations increase worm-pump line pressure and reduce open time during trowel finishing.
Factory production uses horizontal ribbon or plough-share dry-mix blenders with fibre addition after the fine aggregate and air-entraining admixtures have been dispersed; mixing time is 300–420 s at 25–35 rpm. Site mixing is performed with a continuous worm-pump machine, where water addition is set to achieve a wet density between 1,700 kg/m³ and 1,900 kg/m³; outlet pressure is maintained at 20–40 bar through a 25 mm hose. Spray application is executed at a gun distance of 300–500 mm in 6–8 mm passes, with each pass allowed to firm before the next pass is applied. Trowel finishing is delayed until the surface has lost its wet sheen; this is the main process control point because fibres exposed by early troweling cannot be re-embedded after the render reaches initial set.
Terminal finished product types include external masonry render, one-coat coloured facade coatings, renovation render over existing concrete, and decorative vertical garden support coats. The product does not provide tensile strength for crack bridging in movement joints, and movement joint locations remain fixed by the facade engineer under EN 13914-2:2016.
Thin-bed cementitious tile adhesives and floor grouts carry SikaFiber 20 PPM PH at low dry-mix mass fractions where early film formation and notch-slump resistance determine open time on low-porosity substrates. The relevant compliance references are ISO 13007-2:2010 for ceramic tile adhesive classification, EN 12004:2007+A1:2012 for cementitious adhesive performance, ANSI A118.4 for latex-portland cement mortars, and ANSI A118.7 for polymer-modified cement grouts. Formulation addition ratio is 0.05–0.2% by total dry powder mass; dosages above 0.25% are not used because the fibre network increases the yield stress of the mixed mortar and interferes with rib collapse under standard tile bedding.
Production is conducted in a double-shaft plough blender or twin-ribbon mixer; the fibre is metered after the fine fillers have been fully dispersed to prevent partial agglomeration. Mixing time is 240–360 s at 20–30 rpm, followed by bagging into 25 kg valve sacks. At the job site, water addition is controlled between 5.0 L and 6.5 L per 25 kg bag; the mortar is troweled with a 6–10 mm notched trowel and the tile is embedded with a twisting motion to collapse the ridges. The fibre reduces early plastic shrinkage in thick-bed segments around floor drains and movement joints, but does not alter the adhesive’s tensile adhesion strength classification.
Terminal finished product types include C2TE-class tile adhesives for large-format porcelain tiles, floor levelling compounds, cementitious grout for joints up to 6 mm, and stone-fixing mortars for low-absorption natural stone. When the fibre is used in grout, the joint width and movement accommodation remain determined by ANSI A118.7 and the tile system design.
Competitive SikaFiber 20 PPM PH - Monofilament Polypropylene Microfiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Designated SikaFiber 20 PPM PH, the product is a monofilament polypropylene microfiber intended for cementitious matrices including cast-in-place slabs, precast elements, screeds, mortars, and wet-mix shotcrete. The commercial designation identifies a discrete, circular-section polypropylene homopolymer filament; within the SikaFiber nomenclature, the numerical field is conventionally associated with a nominal cut length of 20 mm, and the product falls under EN 14889-2:2006 Class I because the nominal filament diameter is below 0.30 mm. A nominal filament diameter of 20 μm yields an aspect ratio of approximately 1.0 × 10³. At a polypropylene density of 0.91 g/cm³, geometric calculation from the nominal dimensions gives approximately 1.75 × 10⁸ fibres per kilogram. The product is therefore a high-fibre-count microsynthetic reinforcement for plastic-state crack control rather than a structural load-bearing fibre.
Because the product is microsynthetic, it is not assigned a structural fibre class in the manner of deformed steel fibres or Class II macro-synthetic fibres. Its primary function is to increase the number of crack-arresting inclusions per unit volume while maintaining a low volumetric substitution. At a dosage of 0.9 kg/m³, the volumetric fraction is approximately 0.1%, and the calculated fibre population is roughly 1.57 × 10⁸ fibres/m³ throughout the section. A conventional welded wire mesh with 150 mm × 150 mm openings provides a discrete crack-control layer, whereas these fibres provide distributed inclusions of random orientation that do not supply directional strength.
In purchase specifications, SikaFiber 20 PPM PH is defined by model name, compliance to EN 14889-2:2006 Class I, classification as a Type III synthetic fibre under ASTM C1116/C1116M-10a, nominal length 20 mm, nominal diameter 20 μm, and the dosage determined by trial batching. The polypropylene homopolymer constituent is subject to the same REACH registration requirements as other polymer fibres supplied in the European Union; safety data sheets and batch certificates should be requested for each supply lot.
Plastic shrinkage cracking occurs when capillary pressure in the fresh concrete exceeds the low tensile capacity of the hydrating paste, typically within the first 6 h after placement at evaporation rates above 1.0 kg/m²/h. The monofilament geometry of SikaFiber 20 PPM PH provides a dispersed network of fine, flexible fibres that bridge microcracks as they initiate and redistribute local tensile stress across adjacent paste zones. Because the calculated fibre count is on the order of 1.57 × 10⁸ fibres/m³ at a dosage of 0.9 kg/m³, the average inter-fibre spacing is small enough to intersect plastic shrinkage microcracks before they coalesce into visible map cracking. The limiting parameter is not fibre tensile strength but the low elastic modulus of polypropylene, reported in supplier literature for commercial monofilament grades as 3.0–4.5 GPa according to ISO 527-1:2019. Hardened concrete typically exhibits a secant modulus in the range of 25–35 GPa; the modulus mismatch means that once a crack has opened beyond the early microcracking stage, the monofilament elongates or pulls out rather than transferring significant post-crack structural load.
In restrained cracking evaluations conducted under ASTM C1579-21, monofilament polypropylene microfibres of this class are commonly introduced at dosages between 0.6 kg/m³ and 1.8 kg/m³ to reduce crack area and maximum crack width relative to unreinforced reference panels. The benefit depends on fibre count and the ability of the mixing sequence to disperse the filaments without forming fibre balls. Published test reports specific to SikaFiber 20 PPM PH are limited outside the manufacturer’s controlled distribution documentation; therefore project-specific verification against ASTM C1579-21 is required before the product is accepted for plastic shrinkage crack control. The fibrillar network also reduces plastic settlement and bleed-channel formation under early-age evaporation, but it does not lower the internal capillary pressure of a self-desiccating paste.
Representative physical data for 20 mm monofilament polypropylene microfibres of the same class as SikaFiber 20 PPM PH are summarised in the table. Certified lot-specific values shall be taken from the manufacturer’s batch certificate and not from generic literature. The ranges reflect commercial polypropylene homopolymer fibre grades tested according to the indicated methods.
| Property | Test method | Representative value |
|---|---|---|
| Filament length | Manufacturer batch certificate | 20 mm |
| Filament diameter | Optical microscopy / batch certificate | 20 μm |
| Aspect ratio | Calculated length/diameter | 1.0 × 10³ |
| Density | ISO 1183-1:2019 or ASTM D792-20 | 0.90–0.92 g/cm³ |
| Tensile strength | ISO 527-1:2019 | 300–500 MPa |
| Tensile modulus | ISO 527-1:2019 | 3.0–4.5 GPa |
| Melting temperature | ISO 11357-3:2018 | 160–170 °C |
| Water absorption | ASTM D570-98(2018) | < 0.1% |
| Calculated fibre count | Geometry and density calculation | ≈ 1.75 × 10⁸ fibres/kg |
Chemical resistance of polypropylene homopolymer in cement pore solution is based on its non-hydrophilic character and saturated hydrocarbon structure. Water absorption below < 0.1% under ASTM D570-98(2018) indicates that the fibre will not leach or swell in cement paste at pH 12.4–13.5. Thermal stability does not extend to high-temperature processing above the melting onset near 160 °C; steam curing at temperatures below 80 °C and normal exposed concrete surface temperatures do not exceed this threshold, but hot-mix asphalt or autoclave exposure is outside the intended envelope. Storage should be in undamaged original packaging at 5–35 °C and relative humidity below 60% to avoid surface condensation and fibre matting, even though the polypropylene substrate itself is hydrophobic.
Addition of SikaFiber 20 PPM PH to a central mix concrete batch is typically sequenced after aggregate charging and before the addition of cement or mix water. Field batching records from precast operations show that delayed addition of fibres to a wet mortar can produce fibre balls at dosages above 1.0 kg/m³, whereas addition to moving aggregate in a twin-shaft compulsory mixer provides adequate mechanical opening of the filaments. A dosage of 0.9 kg/m³ corresponds to a volumetric fraction of approximately 0.1% by volume of concrete and introduces roughly 1.57 × 10⁸ fibres/m³; this dosage is generally sufficient for plastic shrinkage crack control in slabs and pavements where the evaporation rate is controlled below 1.0 kg/m²/h. Truck-mixer batching should include a minimum 70–100 revolutions at high mixing speed after all ingredients are charged, with slump verified by ASTM C143/C143M. If slump loss exceeds 30 mm relative to the reference mix, adjustments should be made with an ASTM C494/C494M Type F high-range water-reducing admixture rather than by adding water beyond the design water-cement ratio.
Cast-in-place slabs-on-grade and pavements are the most common application. At 0.9 kg/m³, the fibres are distributed through the full thickness; cut edges and joints do not require special treatment. In precast elements, the fibre is used to reduce demolding damage and edge cracking, provided the addition sequence is controlled in the plant mixer. For cementitious screeds and repair mortars, the dosage is usually reduced to 0.6–0.9 kg/m³ to avoid surface fuzz and to maintain trowelability; the final dosage is set by field trials because cement paste volume and sand grading affect fibre distribution.
In fire-resistant high-strength concrete, polypropylene microfibres of this class are sometimes introduced at 1.0–2.0 kg/m³ to provide pressure-relief channels after fibre melting at 160–170 °C; the relevant performance criterion is not fibre tensile strength but the fire resistance of the concrete member under EN 1363-1 or ISO 834-1 exposure. Published data for this specific SikaFiber grade under hydrocarbon fire curves is limited, so the dosage for fire-induced spalling control must be established through member-scale testing.
When the fibre addition point is moved from aggregate charging to post-mix addition, the mixture workability changes more than the absolute fibre dosage would predict. If SikaFiber 20 PPM PH is introduced before the mix water, the hydrophobic filaments are opened by aggregate shear and the risk of agglomeration is lower. If the fibres are introduced into a high-water-content mortar after initial mixing, local water films around the fine filaments create transient balls that resist breakdown. This failure mode is documented in production-scale mixing records from tunnel lining shotcrete operations using high-shear continuous mixers, where pre-dispersion of dry fibre into aggregate improved fibre count uniformity across successive batches. At dosages above 1.2 kg/m³, the high calculated specific surface area of approximately 2.2 × 10² m²/kg can measurably reduce the free water available for slump; therefore the mix design should be re-optimised with a polycarboxylate ether superplasticiser conforming to ASTM C494/C494M Type F. In pumped concrete, the discrete filaments modify the internal structure of the lubricating layer, but published data for this specific product under long-distance pumping through pipe lengths beyond 200 m is limited.
SikaFiber 20 PPM PH is not specified as primary reinforcement, as a replacement for welded wire reinforcement, or as a means of providing post-crack residual strength in structural members. The fibre has negligible post-crack load transfer under ASTM C1609/C1609M or EN 14651 flexural toughness testing because its elastic modulus is too low relative to the cracked concrete matrix. The product is not intended for use in structural elements exposed to sustained temperatures above 80 °C, in hot-mix asphalt, or in applications where fibres are required to carry load after the concrete matrix has fractured beyond the microcracking stage. No reaction with calcium hydroxide or alkalis in normal portland cement pore solution is known; however, compatibility with air-entraining admixtures, retarders, and shrinkage-compensating admixtures shall be confirmed by a trial batch using the same water chemistry and mixer type as the production installation. Published data for this specific configuration in calcium aluminate cement and magnesium phosphate cement is limited.
The primary distinction within polypropylene microfibres is between monofilament and fibrillated geometry. Fibrillated microfibres are produced as slit-film tapes that open into a network under shear; they show a larger specific surface area but may exhibit more variable dispersion in low-paste concrete. SikaFiber 20 PPM PH belongs to the monofilament class, which is a round-section discrete filament with fewer interfilament branches. Compared with synthetic macrofibres used for structural toughness, which typically have diameters of 0.3–1.2 mm and lengths of 30–55 mm, the 20 μm diameter and 20 mm length place this product in the microsynthetic class. EN 14889-2:2006 Class I microfibres are generally not evaluated for residual flexural strength in the same way as Class II macrofibres under EN 14651. Compared with steel fibres, the product has a density of 0.91 g/cm³ versus 7.85 g/cm³, an elastic modulus of 3.0–4.5 GPa versus approximately 210 GPa, and a much higher fibre count per kilogram. The resulting lower stiffness means steel fibres are used to control crack opening after hardening and to provide moment redistribution in ground-supported slabs, whereas SikaFiber 20 PPM PH is used for early-age crack control where the crack width is less than 0.2 mm. The polypropylene monofilament does not generate corrosion staining, which is a practical advantage over steel fibres in exposed architectural surfaces, but it cannot replace steel fibres in structural load-transfer applications.
| Parameter | SikaFiber 20 PPM PH monofilament microfibre | Fibrillated PP microfibre | Synthetic PP macrofibre | Steel fibre |
|---|---|---|---|---|
| Nominal diameter | 20 μm | < 300 μm | 0.3–1.2 mm | 0.5–1.0 mm |
| Nominal length | 20 mm | 6–19 mm | 30–55 mm | 30–60 mm |
| Density | 0.91 g/cm³ | 0.90–0.92 g/cm³ | 0.90–0.92 g/cm³ | 7.85 g/cm³ |
| Elastic modulus | 3.0–4.5 GPa | 1.5–4.0 GPa | 3.0–10 GPa | 210 GPa |
| Typical dosage | 0.6–1.8 kg/m³ | 0.6–1.5 kg/m³ | 2.0–8.0 kg/m³ | 20–50 kg/m³ |
| Primary function | Plastic shrinkage crack control | Plastic shrinkage crack control | Post-crack toughness and load transfer | Post-crack strength and crack-width control |
| Post-crack residual capacity | Negligible | Negligible | Significant under EN 14651 | Significant under EN 14651 |
| Corrosion risk | None | None | None | Surface staining possible |
In wet-mix shotcrete, the inclusion of monofilament polypropylene microfibres at 0.6–0.9 kg/m³ has been used to reduce rebound and improve green cohesion; however, published data for SikaFiber 20 PPM PH in dry-mix shotcrete applications is limited. The fibre is not a substitute for macrosynthetic or steel fibres in shotcrete linings requiring post-crack toughness, and the performance of the fibre-reinforced shotcrete shall be evaluated by the same test methods used for the plain shotcrete reference mix.