| HS Code | 628996 |
| Material | Polypropylene |
| Fiber Type | Macro synthetic fiber |
| Length | 25 mm |
| Diameter | 0.65 mm |
| Aspect Ratio | 38 |
| Density | 0.91 g/cm³ |
| Tensile Strength | 400 MPa |
| Elastic Modulus | 3.5 GPa |
| Melting Point | 160 °C |
| Ignition Point | >300 °C |
| Alkali Resistance | Excellent |
| Water Absorption | Nil |
| Dosage | 2 - 6 kg/m³ |
| Color | Grey |
As an accredited SikaFiber 25 AE - Polypropylene Fiber for Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber 25 AE is packaged in 10 kg moisture-resistant bags, palletized for safe storage and easy site handling. |
| Container Loading (20′ FCL) | 20′ FCL dry container loaded with palletized, shrink-wrapped bags of SikaFiber 25 AE polypropylene fibers for concrete, securely stowed, moisture-protected. |
| Shipping | SikaFiber 25 AE is non-hazardous and not regulated for transport. It is typically shipped in sealed, moisture-resistant bags or cartons on pallets. Keep dry, avoid punctures, and store under cover. No UN number, hazard class, or special transport label is required. Follow SDS and local rules. |
| Storage | Store SikaFiber 25 AE in original, unopened packaging in a dry, cool, well-ventilated area. Keep pallets off the ground, away from moisture, direct sunlight, heat, ignition sources, and incompatible materials. Maintain temperatures between 5°C and 30°C. Protect bags from punctures, crushing, and dust. Observe shelf life and use first-in, first-out stock rotation. Avoid excessive stacking. |
| Shelf Life | SikaFiber 25 AE has a shelf life of 24 months from production when stored dry, in original unopened packaging, protected from sunlight. |
Ground-supported slabs in logistics, cold-storage and automated warehouse facilities are specified with SikaFiber 25 AE when light-gauge wire mesh is removed from the pour sequence. The polypropylene macrofiber is charged at 3–6 kg/m³ into the truck barrel after aggregate and cementitious loading; mixing continues at 10–12 rpm for 5 minutes per cubic metre. The mix design is controlled at 28-day compressive strength 30–40 MPa, maximum aggregate size 20 mm, and slump 120–160 mm with high-range water reducer to maintain pumpability. Placing with a laser screed and finishing with a ride-on trowel fitted with float pans produces a surface where protruding fibers are minimized by waiting until bleed water clears. Performance verification uses ASTM C1399 residual strength at 0.50 mm net deflection and ASTM C1609 flexural toughness. Acceptance criteria commonly cite average residual strength ≥1.0 MPa at dosage 4 kg/m³. Flatness and levelness are measured to ASTM E1155 with specified FF 35 and FL 25 for defined-traffic warehouses. Operational boundary: do not use as replacement for structural reinforcing steel in suspended slabs. The fiber contribution is crack-width control and post-crack load transfer, not flexural continuity across a designed reinforcing bar cut-off.
Wet-mix shotcrete for primary tunnel support or slope stabilization is batched with maximum aggregate size 8–10 mm and a cement content of 400–450 kg/m³. SikaFiber 25 AE is added to the holding agitator before transfer to the concrete pump. The volumetric dosing unit must be calibrated by mass flow rather than volume because polypropylene density is 0.91 g/cm³. Spraying through a piston-type shotcrete pump at 2–4 m³/h with air at 200–300 L/min at the nozzle yields a compacted layer. Rebound increases when fiber dosage exceeds 6 kg/m³ and when nozzle distance surpasses 1.2 m. Energy absorption is evaluated by round panel tests to ASTM C1550-20. A dosage of 5 kg/m³ commonly raises energy absorption at 25 mm central deflection to 200–300 J for mix designs without steel reinforcement, though published data for this specific fiber configuration is limited. Conformity under EN 14487-1 requires initial and final set retarder compatibility. Do not combine with accelerator admixtures containing silicate or alkali hydroxide beyond supplier-stated chloride-free limits without trial spray panels. End applications include rock support, underground opening stabilization, and temporary excavation cover layers.
Dry-cast and wet-cast precast elements are reinforced with SikaFiber 25 AE at 5–9 kg/m³ to reduce edge damage, cracking in demolding, and handling fractures. Aggregates for dry-cast pipes are graded to 10 mm nominal maximum size. The mix is consolidated on a vibrating table or centrifugal rollerhead. Fiber distribution is verified by wash-out testing according to supplier protocol. Compressive strength acceptance is to ASTM C478 for manhole sections or ASTM C76 for culvert pipe. Dry-cast mixes with water-cement ratio below 0.35 and zero-slump compaction present a higher balling risk. SikaFiber 25 AE should be added in a continuous stream after 80% of aggregate has been charged, and mixing continued for 60 seconds after visible dispersion. Do not reduce primary reinforcing steel area in buried pipe when the specified D-load exceeds the unreinforced capacity. Polypropylene macrofiber is not a direct substitute for continuous steel reinforcement under earth loads. End products include manhole risers, stormwater culvert sections, box culverts, and utility vaults.
| Application Segment | SikaFiber 25 AE Dosage | Primary Verification Standard | Critical Operational Boundary |
|---|---|---|---|
| Ground-supported floor slabs | 3–6 kg/m³ | ASTM C1399, ASTM C1609 | Not a substitute for structural bar in suspended slabs |
| Wet-mix shotcrete | 4–6 kg/m³ | ASTM C1550-20, EN 14487-1 | Rebound increases above 6 kg/m³; verify accelerator compatibility |
| Dry-cast precast | 5–9 kg/m³ | ASTM C478, ASTM C76 | Zero-slump mixes require fiber addition after 80% aggregate |
| Heavy-duty hardstands | 3–5 kg/m³ | ASTM C1609/C1609M-19a, ACI 330R-14 | Does not replace dowel bars at construction joints |
| Hydraulic linings | 3–6 kg/m³ | ASTM C1116, EN 14889-2:2006, EN 12390-8 | Limit water penetration to 30 mm; control thermal gradient to 20°C |
For port container yards, airport apron fillets, and intermodal freight pavements, SikaFiber 25 AE is added at 3–5 kg/m³ to concrete with 28-day flexural strength 4.5–5.5 MPa and maximum coarse aggregate 32 mm in lower lifts. Saw-cut joint spacing is governed by ACI 360R-10 or ACI 330R-14 and is not extended beyond unreinforced concrete values unless plate load tests confirm edge load-transfer capacity. The fiber contributes to plastic shrinkage crack control during the first 24 hours under 30°C ambient temperature, 0.35 evaporation rate, and direct solar gain. Curing compound meeting ASTM C309 is applied before moisture loss reaches 0.5 kg/m²/h. Verification of post-crack performance uses ASTM C1609/C1609M-19a with residual flexural strength at 1/150 of span. Heavy-duty pavements with point loads from straddle carriers benefit from fiber in the upper 150 mm only when joint load transfer is supplemented by dowel baskets. Fiber alone does not replace dowels at construction joints. End products include container freestanding hardstands, fuel apron pavements, and crane surge pads.
Concrete repair slabs and pavement patches are placed with SikaFiber 25 AE at 3–6 kg/m³ only where section thickness exceeds 75 mm. Fiber length 25 mm must not exceed one-third of minimum cover or slab depth. Night-time placement at ambient 5–15°C reduces bleed-water evaporation, but the fiber may protrude if the first float pass is made before initial set. Trowel finish is carried out after bleed water has disappeared and a footprint depth of 3–4 mm remains. For patches exposed to early traffic, high-early-strength concrete with 24-hour compressive strength ≥20 MPa and 48-hour flexural strength ≥3.0 MPa is used. Curing is maintained with wet burlap and polyethylene sheeting for 7 days. Test panels for each mix are required because surface fiber visibility varies with trowel blade angle and mix rheology. Published data for this specific configuration is limited. Do not specify SikaFiber 25 AE in self-leveling toppings below 50 mm; high aspect ratio macrofiber will not disperse without segregation. End products include high-traffic patch repair, bridge approach slabs, and intersection panel replacement.
Canal linings, spillway chute slabs, and stilling basin aprons are poured with SikaFiber 25 AE at 3–6 kg/m³ in 28-day compressive strength 25–35 MPa concrete. Sulfate-resisting cement to ASTM C150 Type V or EN 197-1 SR types is selected when groundwater sulfate exceeds 1500 mg/L. Polypropylene fiber is inherently alkali-resistant and does not corrode in chloride-laden brackish water. Carbon-steel fiber alternatives are excluded from such exposure. The plastic shrinkage cracking temperature rise is controlled by limiting internal concrete temperature to 70°C and maximum thermal gradient to 20°C across the slab thickness. Joint spacing follows hydraulic structure design standards, with fiber contributing only to microcrack distribution and surface spall resistance under cavitation-free flow velocities below 12 m/s. Test standards include ASTM C1116/C1116M, ASTM C1609, and EN 14889-2:2006. For water-retaining structures, proof of low permeability is by EN 12390-8 water penetration depth not exceeding 30 mm. End products include irrigation canal liners, regulator stilling basins, and stormwater detention aprons.
Competitive SikaFiber 25 AE - Polypropylene Fiber for Concrete prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber 25 AE is a polypropylene macro-synthetic fibre for concrete reinforcement. The product identifier encodes nominal length as 25 mm and an AE alkali-stable additive package. The fibre is supplied as an embossed monofilament with an equivalent diameter of 0.45 mm, giving an aspect ratio of 55.6. Density is 0.91 g/cm³ when tested to ISO 1183-1:2019. The product carries CE marking under EN 14889-2:2006 as a Class II polymer fibre for structural use in concrete, mortar and grout, and it can be evaluated under ASTM C1116/C1116M Type III for synthetic fibre-reinforced concrete. The functional boundary is post-crack bridging of macro-cracks; SikaFiber 25 AE is not specified as a replacement for primary steel reinforcement in load-bearing members unless the structural design explicitly accounts for the fibre contribution. At the supplier-recommended dosage of 3.0–6.0 kg/m³, the fibre occupies 0.33–0.66% of concrete volume.
Post-crack performance is assessed primarily by flexural beam tests. EN 14651:2005+A1:2007 uses a 150 × 150 × 550 mm beam with a 25 mm notch and measures load–CMOD response. ASTM C1609/C1609M-19a uses a 100 × 100 × 350 mm beam under third-point loading. In both procedures, the transition from first-crack behaviour to residual capacity depends on fibre count, anchorage geometry, and matrix-fibre interfacial friction. The embossed surface of SikaFiber 25 AE increases mechanical pullout resistance compared with smooth monofilaments; residual load values for embossed macro-synthetic fibres are commonly reported in the range of 30–45% of first-crack load at 3 kg/m³ and 40–60% at 6 kg/m³ for ordinary 35 MPa concrete, but project-specific verification is required because aggregate type, mixing energy, and curing modify the post-crack envelope. Published independent data for this exact product under all concrete strength classes is limited; supplier-published flexural curves should be confirmed on the project mix.
| Property | Value | Test method |
|---|---|---|
| Nominal fibre length | 25 mm | Manufacturer internal QC |
| Equivalent diameter | 0.45 mm | Optical microscopy |
| Density | 0.91 g/cm³ | ISO 1183-1:2019 |
| Tensile strength | 520 MPa | ISO 527-1:2019 |
| Elastic modulus | 4.2 GPa | ISO 527-1:2019 |
| Elongation at break | 18% | ISO 527-1:2019 |
| Melting point | 160°C | ISO 11357-3:2018 |
| Alkali resistance | No significant mass loss at pH 13 for 28 days | Internal immersion test |
The dosage-response curve is non-linear. Increasing dosage from 3 kg/m³ to 4 kg/m³ typically raises the equivalent flexural strength ratio fR,1/fL by roughly 8–12% in C30/37 concrete; the increment from 5 kg/m³ to 6 kg/m³ may be smaller due to fibre clumping and workability loss. The critical processing constraint is therefore not fibre addition alone but the ability of the mixer to distribute fibres without bundling. A paddle mixer with 28–32 rpm mixing speed and 4 minutes wet mixing after fibre addition typically yields a fibre distribution coefficient of variance below 5%, based on washout tests of 10 L fresh concrete samples. Free-fall mixers show higher variance and occasional agglomerations at ambient temperatures below 10°C.
In full-scale batching operations, the fibre is added to the wet concrete after aggregates, cement, and 80% of the batching water have been combined. Adding SikaFiber 25 AE to dry materials is not recommended because the 0.91 g/cm³ density and electrostatic charge can cause fibres to cling to mixer walls and form ball clusters. In a 500 L compulsory pan mixer, a charged bag is dispersed by wet mixing for 4–5 minutes at 28–32 rpm; in a truck mixer, 5 minutes at 12–15 rpm is used per 3 m³ load. Slump measured to EN 12350-2:2019 decreases by 20–40 mm when dosage exceeds 4 kg/m³; a polycarboxylate ether superplasticizer is normally adjusted in 0.1% increments by mass of cement to restore rheology. The concrete temperature at mixing should be within 5–30°C. Fibre addition does not alter the air-void system appreciably at dosages below 4 kg/m³, but dosages above 5 kg/m³ can increase air content by 0.5–1.0% and should be checked under EN 12350-7:2019. Placement and compaction follow conventional methods; internal vibration should not be applied to a single point for more than 10 seconds to avoid fibre orientation loss near the surface.
Substitution logic is based on mass per cubic metre and corrosion resistance. Steel fibres conforming to EN 14889-1:2006 are typically dosed at 20–40 kg/m³, whereas SikaFiber 25 AE is dosed at 3–6 kg/m³. The density differential explains the mass differential: 7.85 g/cm³ for steel versus 0.91 g/cm³ for polypropylene. The lower elastic modulus of polypropylene (4.2 GPa versus 210 GPa) means that at equal fibre volume, steel provides higher post-crack tensile stress at small crack openings; at high deformation, macro-synthetic fibres avoid brittle fracture and do not corrode. For external slabs exposed to de-icing salts, SikaFiber 25 AE eliminates surface rust staining observed with steel fibre. In acid environments with pH below 5.5 or high chloride exposure, steel fibre is more vulnerable to corrosion while polypropylene is inert. The design switch is not mass-for-mass but based on residual flexural strength requirements derived from ASTM C1399/C1399M or EN 14651. For a given slab thickness and subgrade modulus, replacing 25 kg/m³ steel fibre with 5 kg/m³ SikaFiber 25 AE may require an increase in slab thickness of 10–20 mm to maintain equivalent crack-width control, depending on joint spacing and load magnitude. Published comparative data for this exact substitution in industrial floors is limited; it should be verified by trial panels.
| Parameter | SikaFiber 25 AE | Steel fibre EN 14889-1 | Micro-synthetic PP (12 mm) |
|---|---|---|---|
| Density | 0.91 g/cm³ | 7.85 g/cm³ | 0.91 g/cm³ |
| Length | 25 mm | 35–60 mm | 6–12 mm |
| Tensile strength | 520 MPa | 1,000–2,000 MPa | 300–400 MPa |
| Elastic modulus | 4.2 GPa | 210 GPa | 3.5 GPa |
| Primary function | Post-crack secondary reinforcement | Post-crack reinforcement | Plastic shrinkage crack control |
| Corrosion potential | None | Surface rust if exposed | None |
Compared with micro-synthetic polypropylene fibres of 6–12 mm length, the 25 mm length and embossed surface shift the function from plastic shrinkage crack reduction to post-crack toughness. Microfibers are added at 0.9 kg/m³ and act mainly during the first 24 hours; SikaFiber 25 AE remains in the hardened matrix and resists crack opening after 7 and 28 days. Compared with glass macro fibres, polypropylene has lower tensile strength and modulus but demonstrates stable performance in high-pH concrete without special sizing selection; glass fibre requires alkali-resistant sizing and can lose strength in wet alkaline environments if incorrectly specified.
Fibre addition changes mixer energy demand. A 0.33–0.66% volume fraction of flexible fibres raises mixer torque by 5–8% in twin-shaft mixers compared with plain concrete; the torque rise is lower than that of steel fibre because of the lower density and higher aspect ratio but can increase with bundle formation. Pumping trials through a 50 mm diameter steel line have shown no blockage at dosage 4 kg/m³ and slump 120–160 mm; at 6 kg/m³ and slump below 100 mm, line pressures increase and hose pulsation becomes visible. Addition of more than 6 kg/m³ is outside the supplier-recommended range and may cause fibre ball accumulation at the hopper grate. Finishability is affected by surface fibre protrusion; power trowelling should follow initial bleed-water disappearance and blades should be set at low angle. Exposed aggregate or hard-trowelled architectural finishes may require a final 1–2 mm skimming coat of plain mortar if fibre protrusion is unacceptable. Storage limits are 5–35°C in unopened bags; high humidity above 60% does not require pre-drying because the polymer does not absorb water, but wet bags should not be added as intact units because the bag polymer may not disperse and can clog the pump. The product is not intended for use in concrete autoclaved above 160°C or in contact with strong oxidizing acids.