    Specifications
    HS Code 522444
    Product Name SikaFiber 600 CO - 18 mm Long Monofilament Polypropylene Microfiber for Concrete and Mortar
    Material 100% Polypropylene
    Fiber Type Monofilament
    Length 18 mm
    Diameter 0.02 mm
    Aspect Ratio 900
    Density 0.91 g/cm³
    Melting Point 160 °C
    Ignition Point >350 °C
    Tensile Strength >400 MPa
    Young S Modulus >3500 MPa
    Elongation At Break 15-20%
    Water Absorption Nil
    Alkali Resistance Excellent
    Acid Resistance Excellent
    Dosage 0.6 kg/m³ (concrete), 0.9 kg/m³ (mortar)
    Packaging 0.6 kg bags
    Color White
    Shelf Life 5 years
    Storage Dry, protected from direct sunlight
    Standards EN 14889-2, ASTM C1116

    As an accredited SikaFiber 600 CO - 18 mm Long Monofilament Polypropylene Microfiber for Concrete and Mortar factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SikaFiber 600 CO is supplied in 600 g moisture-resistant paper bags, 20 bags per carton, for concrete/mortar.
    Container Loading (20′ FCL) SikaFiber 600 CO 18 mm monofilament polypropylene microfibers for concrete/mortar, palletized, shrink-wrapped, strapped, loaded in a 20′ FCL container.
    Shipping SikaFiber 600 CO, 18 mm long monofilament polypropylene microfiber, ships as a non-hazardous, non-flammable solid in moisture-resistant bags or boxes on pallets. Transport in clean, dry vehicles; protect from moisture, punctures, and sunlight. No special DOT/ADR restrictions apply. Store indoors at ambient temperature, away from ignition sources. Handle with care.
    Storage Store SikaFiber 600 CO in its original, unopened packaging in a cool, dry, well-ventilated area. Protect from moisture, direct sunlight, and extreme temperatures. Keep away from ignition sources and incompatible chemicals. Maintain sealed bags or containers to prevent contamination and dust. Stack securely to avoid bag damage. Observe manufacturer’s shelf-life and handling instructions. Store indoors, off damp floors.
    Shelf Life Shelf life is 24 months from manufacture when stored in original, unopened packaging under dry conditions, away from direct sunlight.
    Application of SikaFiber 600 CO - 18 mm Long Monofilament Polypropylene Microfiber for Concrete and Mortar

    Continuous slab-on-grade pours for high-density logistics buildings are evaluated against the plastic-shrinkage cracking window defined by ASTM C1579-21 and the jointed plain-concrete provisions of ACI 302.1R-15 and ACI 360R-10; the 18 mm monofilament polypropylene microfibre SikaFiber 600 CO is introduced in this segment at 0.9 kg/m³ for standard interior slabs, 1.2 kg/m³ when the evaporation rate measured under ACI 305.1-14 exceeds 0.5 L/m²/h or when discharge temperature exceeds 29 °C, and 1.8 kg/m³ only for unfinished toppings or surfaces that subsequently receive a bonded levelling coat. The downstream batching sequence on ready-mix production lines places the fibre after aggregate, cement, and 80% of batch water plus polycarboxylate superplasticizer have been charged, followed by drum rotation at 6–8 rpm for not less than 5 min; batch-to-batch slump variation recorded against ASTM C143/C143M-15a is typically held within ±15 mm when the fibre is not added to a dry revolving drum. Terminal products include jointless logistics floors, very-narrow-aisle rack slabs, automated storage and retrieval system slabs, freezer slabs, and distribution-center dock approaches. The operational boundary is that the microfibre does not replace saw-cut joint layout or structural steel; at dosages above 1.2 kg/m³, power trowel finish requires a final pan-float pass to minimize surface-visible monofilament debris, and burnishing should be delayed until the surface water sheen disappears.

    What Limits Rebound Reduction and Plastic Crack Suppression in Wet-Mix Tunnel Shotcrete?

    Wet-mix sprayed concrete for temporary tunnel headings and shaft linings places SikaFiber 600 CO at 0.9–1.8 kg/m³, with the lower value applied to heavily accelerator-retarded mixes requiring maximum pumpability and the upper value restricted to flat overhead sections where early-age thermal stress before final permanent lining is limiting. Conformance is established through EN 14487-1:2022 for sprayed concrete specification and conformity, ASTM C1436/C1436M-14a for shotcrete materials, and ACI 506R-16 for application practice; the fibre itself is classified under EN 14889-2:2006 Class I and ASTM C1116/C1116M-10a Type III. The production line for this application uses a twin-shaft continuous mixer or transit-mixer batching with polymer fibre density 0.91 g/cm³ entered into the weigh-cell compensation system, piston-pump transfer at 6–15 m³/h, and air-assisted nozzle pressure of 3–5 bar measured at the nozzle inlet. Terminal product types include temporary tunnel headings, shaft collars, slope stabilization shells, and swimming pool shells where conventional welded-wire mesh is impractical. The limiting processing condition is that the monofilament fibre contributes to plastic-shrinkage crack suppression and rebound control only within normal spray-angle limits; it does not provide post-crack tensile capacity, and published data for this specific configuration is limited, so any crack-width reduction value must be verified on sprayed panels under EN 14488-1:2005 or on cast slabs under ASTM C1579-21 rather than read across from cast slab results.

    Precast Manhole Base and Drainage Channel Mix Rationale Without Mesh Detailing

    Precast drainage components manufactured in vertical battery moulds and horizontal channel forms incorporate SikaFiber 600 CO at 0.9–1.2 kg/m³ in concrete with slump maintained at 200–250 mm for self-compacting formulations or 80–120 mm for external-vibration casting. The relevant compliance framework includes EN 13369:2018 common rules for precast concrete products, EN 1917:2002 for concrete manholes and inspection chambers, and ASTM C1433/C1433M-20 for precast reinforced concrete box sections used in culverts and storm drains. The production process begins in a planetary counter-current mixer with fibre addition after the first 30 s of dry blending, followed by wet mixing for 90–120 s before discharge into forms fitted with external high-frequency vibrators operating at 50 Hz; demolding typically occurs at a concrete cube strength of 10–15 MPa to prevent edge pull-out of monofilaments at sharp form corners. Terminal products include manhole base sections, catch basin bodies, drainage channel segments, box culvert walls, and curb inlets. The operational limitation is that the fibre is not a substitute for reinforcing cages in buried sections subject to traffic surcharge loads under EN 1991 or AASHTO live-load cases, and it should not be used to reduce minimum cover requirements in aggressive soil exposure classes.

    In pumpable calcium-sulphate and cementitious screed systems, the 18 mm monofilament is metered at 0.6–1.2 kg/m³ into the dry-mix line before a continuous D-pump rotor/stator mixing pump; the resulting material is placed under EN 13813:2002 material designation and tested for flexural strength according to EN 13892-1:2002. The downstream process consists of dry mixing in a horizontal forced-action mixer for 45–60 s, water dosing to a flow diameter of 220–260 mm on a DIN flow table, and screed pump transfer at typical delivery rates of 15–25 L/min. Terminal product types include bonded cementitious screeds under hospital corridor vinyl, floating calcium-sulphate underlayments under engineered wood, and rapid-drying renovation toppings. The processing boundary is that SikaFiber 600 CO reduces early-age edge curling and plastic-shrinkage delamination in the first 6 h, but it does not remove the requirement for perimeter isolation joints or saw-cut crack-control joints in tile-bearing installations.

    When Repair Mortar Placement Demands EN 1504-3 Class R2 Compatibility Without Corner Mesh

    Sprayed and trowelled repair mortars for structural and non-structural patching use SikaFiber 600 CO at 0.9–1.5 kg/m³ in the dry-mortar formulation, equivalent to approximately 0.1–0.2% by volume, with the lower boundary for flow-applied fairing coats and the upper boundary for vertical and overhead repairs that previously required light steel mesh. The conformity path is EN 1504-3:2005 for Class R2 or R3 repair mortars, with bond strength verified under EN 1542:1999 and compressive strength classified under EN 12190:1998. The production process includes dry blending in a horizontal ribbon mixer at 20–40 rpm for 3 min after fibre addition, site mixing with a low-speed paddle mixer at 400–600 rpm, and application by trowel or hopper spray in lifts not exceeding 25 mm. Terminal products include concrete repair patches, formed corner recasts, vertical and overhead patch mortars, and fairing coats on bridge piers. The operational limitation is that the hydrophobic polypropylene surface may interact with polymer latex modifiers; a compatibility test under EN 1504-3:2005 identification requirements is required when acrylic or styrene-butadiene dispersions are used as bonding agents, and the fibre does not replace load-transfer dowels in structural repairs.

    Water-retaining and environmental concrete structures such as aeration basins and clarifier walls are placed with SikaFiber 600 CO at 0.9–1.2 kg/m³ to reduce early-age map cracking before the onset of drying shrinkage, with compliance grounded in ACI 350-20 for environmental engineering concrete structures, EN 1992-3:2006 for liquid retaining structures, and watertightness verification under EN 12390-8:2019 or ACI 350.1-20. The placement process uses monolithic concrete pumps and internal immersion vibrators on a grid not exceeding 450 mm centre-to-centre, with the fibre introduced at the plant after the 60% water addition point to avoid clumping in low-slump mixes; joint systems incorporate hydrophilic waterstop and post-crack repair detailing because the microfibre does not independently provide watertightness. Terminal product types include secondary containment bunds, firewater tank bases, sludge digester walls, aeration channels, and clarifier perimeter walls. The processing boundary is that the dosage must not exceed 1.2 kg/m³ in chloride-containing wastewater environments unless an additional hydrophobic pore-blocking admixture is specified, because polypropylene microfibres do not alter the chloride diffusion coefficient measured under ASTM C1556-11a.

    Free Quote

    Competitive SikaFiber 600 CO - 18 mm Long Monofilament Polypropylene Microfiber for Concrete and Mortar prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Supplied as an 18 mm long monofilament polypropylene microfibre, SikaFiber 600 CO is specified for concrete and mortar where early-age plastic shrinkage cracking and microcrack propagation require control without altering the structural reinforcement design. The monofilament geometry differentiates the product from fibrillated polypropylene fibres, and the 18 mm cut length places it in the micro-synthetic fibre class referenced in ASTM C1116/C1116M as Type III synthetic fibre. At the recommended addition range of 0.6–1.8 kg/m³, the dosage produces a distributed array of discrete filaments within the capillary pore network of fresh concrete. The fibre density of approximately 0.91 g/cm³ reduces settling compared with steel fibres, while the hydrophobic polypropylene surface does not absorb mixing water. Because the polymer is non-corroding and chemically resistant to alkaline pore solution, the fibres do not introduce electrochemical compatibility issues into reinforced concrete. The primary function is localised restraint of plastic shrinkage strain; the product is not designed to provide hardened-state post-crack load transfer following matrix rupture.

    SikaFiber 600 CO: Material Constitution and Geometric Classification

    The product is composed of virgin polypropylene extruded as individual monofilaments rather than a fibrillated network. The 18 mm length is longer than typical 3–12 mm microfibres used in thin plasters, but shorter than macro-synthetic structural fibres of 30–65 mm. The low elastic modulus of polypropylene in the range of 3.5–4.5 GPa defines the fibre as a plastic-shrinkage control component rather than a structural reinforcement element. The material does not absorb water, and its density near 0.91 g/cm³ is below that of concrete, which influences flow behaviour and segregation resistance. Resistance to high-alkalinity cementitious environments is screened under EN 14889-2:2006; long-term exposure to pore solution with pH above 12.5 does not degrade the polymer through alkaline hydrolysis. The following table lists supplier-published typical material parameters; batch-specific mill certificate values may vary from the tabulated mid-range.

    Typical physical and compositional parameters for SikaFiber 600 CO
    ParameterTypical valueReference basis
    CompositionVirgin polypropylene monofilamentManufacturer product specification
    Length18 mmCut-length specification
    Density0.91 g/cm³ISO 1183-1
    Tensile strength300–350 MPaISO 527-1
    Elastic modulus3.5–4.5 GPaISO 527-1
    Melting point160 °CDifferential scanning calorimetry
    Water absorption0%ASTM D570
    Recommended dosage0.6–1.8 kg/m³Concrete and mortar batching range
    Standards classMicrosynthetic fibreASTM C1116/C1116M

    The dosage selection depends on exposed surface area, evaporation rate, cementitious paste content, and the required crack-width objective. At 0.9 kg/m³, fibre addition is usually integrated without altering structural design assumptions; at the upper bound of 1.8 kg/m³, the mix may require additional workability management and placement trials.

    When concrete transitions from plastic to setting, capillary menisci in the near-surface zone generate negative pore pressure. Evaporation rates above 0.5 kg/m²/h are recognised as a threshold at which plastic shrinkage cracking risk increases. The dispersed 18 mm fibres intersect crack starts and bridge adjacent microcracks at the nucleation stage, distributing strain over multiple filaments rather than allowing crack coalescence into a single visible fissure. Equivalent 18 mm monofilament polypropylene microfibre systems evaluated under ASTM C1579-21 have shown crack-area reductions of 50–80% relative to plain concrete at 0.9 kg/m³; published data for this specific product configuration are limited, and project-specific verification is appropriate when crack control is critical. The mechanism is defined by fibre pull-out and microcrack bridging in the first 24 hours after placement, not by post-crack structural capacity. Once the hardened cement matrix has cracked and the short fibre length is exceeded by crack opening, residual flexural contribution under EN 14651:2005+A1:2007 is negligible at normal dosage.

    Rheologically, the inclusion of hydrophobic monofilaments does not increase yield stress in proportion to their mass dose because the fibres rotate with the plastic flow and align with shear direction. At 0.9 kg/m³, the calculated fibre volume fraction is approximately 0.1% of concrete volume. In low-paste mixes with cementitious contents below 300 kg/m³, the fibres can increase cohesiveness by filling interstitial space between aggregate particles, but this effect is smaller than the workability loss caused by fibres with high aspect ratio. At 1.8 kg/m³, the volume fraction rises to approximately 0.2%, and the increased surface area may require additional paste or a high-range water-reducing admixture to maintain the target slump. These limits explain why the product is not used as a substitute for macro-synthetic fibres in structural slab design.

    What operational boundary separates SikaFiber 600 CO use from structural macro-fibre reinforcement?

    The main distinction is anchored in length, dosage, modulus, and qualification method. The 18 mm monofilament is below the critical anchorage length needed for substantial post-crack residual strength in hardened concrete. The 3.5–4.5 GPa elastic modulus of polypropylene is approximately 50 times lower than that of steel fibres, and the tensile strength of 300–350 MPa does not compensate for the low modulus when stress is transferred across a cracked plane. The product is not specified for structural use under EN 14651:2005+A1:2007 or ASTM C1609/C1609M. The following table compares the product with macro-synthetic and steel fibre classes.

    Fibre class comparison for concrete placement
    Fibre classTypical lengthTypical dosagePrimary qualificationHardened-state contribution
    SikaFiber 600 CO microsynthetic18 mm0.6–1.8 kg/m³ASTM C1579-21, EN 14889-2:2006Plastic shrinkage crack reduction; no structural post-crack residual strength
    Macro-synthetic polyolefin30–65 mm2–8 kg/m³EN 14651:2005+A1:2007, ASTM C1609/C1609MPost-crack residual flexural toughness in ground-supported slabs and shotcrete
    Cold-drawn steel fibre25–60 mm20–60 kg/m³EN 14651:2005+A1:2007, ASTM C1609/C1609MPost-crack flexural resistance and possible partial shear reinforcement

    Compared with fibrillated polypropylene microfibres, monofilament geometry provides a lower surface-area-to-mass ratio and disperses as separate filaments in truck mixers, reducing clumping at similar dosages. Compared with steel fibres, the product does not reduce concrete electrical resistivity, does not generate corrosion staining, and is lighter to handle; a 0.9 kg/m³ microsynthetic dose is approximately 4.5% of the mass of a 20 kg/m³ steel-fibre dose for the same nominal slab volume. Compared with polyvinyl alcohol microfibres, polypropylene has lower modulus and interfacial bond strength, but it is used for plastic shrinkage control rather than engineered tensile strain-hardening composites. Compared with glass fibres, no special alkali-resistant sizing is required because the polypropylene matrix is not dissolved by cement pore solution.

    At central-mix and truck-mix plants, batching sequence controls dispersion. Adding the pre-weighed 18 mm fibre dose onto the aggregate conveyor before cement charging uses aggregate shear to distribute the filaments; in dry-batch trucks, delaying fibre addition until approximately 70% of the mix water has wet the aggregate surface prevents dry-cement balling. Ready-mix drums should be mixed at 8–12 rpm for 5–7 minutes after fibre addition. Paddle and pan mixers require longer wet mixing because shear gradients are lower than in high-intensity horizontal shaft mixers. A recognised plant-scale failure mode is polypropylene clumping when the entire dose is introduced into dry cement before water. The corrective sequence is to split the fibre dose into 2 additions or delay fibre charging until the mixture has reached the wet-plastic state. Slump response should be recorded for the first 3 production batches using ASTM C143/C143M or EN 12350-2. If slump loss exceeds 30 mm from the reference mix, the dosage should be reviewed or a compatible high-range water-reducing admixture introduced after the fibres are fully dispersed.

    Compliance pathways, dosage limits, and incompatibilities in concrete and mortar

    Within the European Economic Area, polymer fibres for structural concrete are covered by EN 14889-2:2006. The product must be accompanied by a declaration of performance and CE marking when used under EN 206. In North American specifications, polypropylene fibres are classified as Type III synthetic fibres under ASTM C1116/C1116M, and the fibre material is qualified by its physical properties rather than by a structural design formula. The addition rate of 0.6–1.8 kg/m³ does not modify the minimum steel reinforcement ratios required by EN 1992-1-1 or ACI 318-19. At the upper dosage, polypropylene fibres melt at 160 °C and create channels that may relieve internal vapour pressure during fire exposure. For fire-induced spalling control in high-strength concrete, dosages of 1.5 kg/m³ or higher are sometimes specified, but published data for this specific product configuration under ISO 834-1 are limited; furnace calibration and full-scale verification are required before a fire-resistance rating can be stated.

    Operational boundaries include the absence of structural reinforcement function, the need for wet mixing at high dosage, and the lack of post-crack residual strength under EN 14651:2005+A1:2007. The fibre is compatible with conventional air-entraining, accelerating, and water-reducing admixtures when the addition sequence is controlled. In air-entrained concrete, the air-entraining agent should generate a stable air-void system before the fibre charge; air content is then checked by ASTM C231/C231M or EN 12350-7 because the hydrophobic fibre surface can alter air-void rheology and surface tension measurements. The product should not be used as a replacement for steel reinforcing bars, welded wire fabric, or structural macro-synthetic fibres in load-bearing elements. Storage should be in a dry, covered area before batching; polypropylene is UV-sensitive before placement but protected by the cement matrix after hardening.

    For mortar and render applications, the lower end of the dosage range, 0.6–0.9 kg/m³, is used when application thickness is below 50 mm. The 18 mm fibre length is suitable for spray-applied mortars if the nozzle outlet is free of constrictions that can trap monofilaments; worm-pump and rotor-stator pump systems handle the fibres with less breakage than high-pressure piston pumps with small valve clearances. In pre-bagged dry-mix mortars, the fibres are pre-blended with sand and cement; static charge can cause fibre adherence to mixer walls and weigh hoppers under low-humidity conditions. Field experience indicates that maintaining aggregate moisture above 0.5% or adding the fibre to the wet mixer after initial powder wetting reduces static clustering. Published data for this specific product configuration are limited in thin spritz renders; batching trials should validate surface finish, fibre visibility, and pump pressure increase of less than 10% relative to unfibred mix.

    In dense, low-permeability concrete exposed to rapid temperature rise, polypropylene fibres melt and leave channels when the matrix reaches approximately 160 °C. The resulting permeability increase reduces internal pore pressure and lowers spalling risk. The effect depends on fibre count, length, and dispersion; 18 mm monofilament provides interconnected pathways if fibre spacing is small enough. The typical dosage range for this mechanism is 1.5–2.0 kg/m³, although 2.0 kg/m³ is above the general recommended dosage upper bound of 1.8 kg/m³; therefore fire-performance mixes should be established by trial and furnace testing.