| HS Code | 839923 |
| Product Name | SikaFiber 618 PPM - Monofilament Polypropylene Fiber for Concrete and Mortars |
| Material | 100% virgin polypropylene |
| Fiber Type | Monofilament |
| Fiber Length | 6 mm |
| Fiber Diameter | 0.018 mm |
| Aspect Ratio | Approximately 333 |
| Density | 0.91 g/cm³ |
| Melting Point | 160–170 °C |
| Tensile Strength | 400–700 MPa |
| Young S Modulus | 3–5 GPa |
| Elongation At Break | 15–20% |
| Alkali Resistance | Excellent |
| Water Absorption | Nil |
| Dosage | 0.6–0.9 kg/m³ |
| Packaging | 0.6 kg bags |
| Color | Natural/white |
| Standards | ASTM C1116, EN 14889-2 |
As an accredited SikaFiber 618 PPM - Monofilament Polypropylene Fiber for Concrete and Mortars factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber 618 PPM is packaged in 0.6 kg water-soluble bags, 20 bags per carton (12 kg total). |
| Container Loading (20′ FCL) | 20′ FCL: palletized SikaFiber 618 PPM monofilament polypropylene fiber for concrete and mortars, securely loaded in a standard dry container. |
| Shipping | SikaFiber 618 PPM is shipped in moisture-resistant bags or cartons, palletized and shrink-wrapped. It is non-hazardous and not regulated as dangerous goods. Transport in clean, dry vehicles. Store in original packaging, protected from moisture, direct sunlight, and excessive heat. Handle with care to avoid package damage. No special handling required. |
| Storage | Store SikaFiber 618 PPM in its original, unopened packaging in a dry, cool, well-ventilated area. Protect from direct sunlight, moisture, heat, and ignition sources. Keep bags sealed and off the ground; avoid excessive stacking or package damage. Maintain good housekeeping and follow local regulations, SDS, and manufacturer instructions. Shelf life may be reduced by improper storage. |
| Shelf Life | Shelf life: 24 months from production if stored unopened in original packaging, dry conditions, protected from moisture and direct sunlight. |
Industrial slab-on-grade specifications for logistics buildings, automated storage and retrieval systems, and high-bay racking floors routinely require plastic shrinkage crack control because finishing windows are compressed by early-age hydration, low relative humidity, and laser-screed operations. Addition of SikaFiber 618 PPM at 0.9–1.5 kg/m³, with an upper limit of 1.8 kg/m³, is batched after aggregate pre-wetting but before the full water content in a twin-shaft compulsory mixer at 45–60 seconds wet mixing; dosage below 0.6 kg/m³ may not disperse sufficiently in low-cement content slab mixes, while dosage above 1.8 kg/m³ can produce monofilament balling on paddle faces and increase mortar viscosity to the point where ASTM E1155-20 F_F 40/F_L 30 floor flatness values degrade during pan-trowel finishing. Relevant compliance pathways are ASTM C1116/C1116M-23 Type III synthetic fibre reinforcement, EN 14889-2:2006 for CE-marked polymer fibres, ACI 302.1R-15 for slab placement, and ASTM C1579-21 for restrained plastic shrinkage evaluation; project specifications often require a maximum crack width of 0.3 mm under the C1579 test at 1.0 kg/m³. The production process follows laser-screed strike-off, vibratory screed consolidation, bull float cutting, and multiple power-trowel passes; fibres are not visible in the finished surface when dosage remains below 1.5 kg/m³, but dry-shake hardeners must be applied before final trowelling because protruding monofilaments can interrupt the mechanical bond of surface densifiers. Finished floor slab types produced with this fibre include jointless racking slabs, very narrow aisle floors with F_F 40/F_L 30 classes, external hardstandings, and internal logistics decks; the fibre is not a substitute for sawn joints or structural reinforcement, and load-induced crack width control under rack leg point loads still requires dowelled joints and conventional slab reinforcement.
Wet-mix shotcrete in underground hard-rock headings and tunnel lining applications benefits from monofilament polypropylene addition at 0.9–1.2 kg/m³ when plastic shrinkage cracking on freshly sprayed surfaces and passive fire-induced spalling are considered; the fibre is metered into a transit mixer or batching plant before discharge into a positive-displacement concrete pump operating at 60–90 bar outlet pressure, and compressed air at 7–10 bar is injected at the nozzle to project the mixture onto the substrate. Standards governing this segment include EN 14487-2:2006 for sprayed concrete execution, ACI 506R-16 for shotcrete guidance, ASTM C1436 for wet-mix sprayed concrete materials, and EN 14889-2:2006 for polymer fibre conformity; rebound behaviour is controlled by nozzle angle and air flow rather than fibre volume, but fibre addition tends to increase the yield stress of the fresh mix and may require a polycarboxylate ether adjustment of 0.1–0.3% by cement mass to maintain pumpability. Production is performed with robotic arm manipulation on 30–60 m³/h daily placement programmes, and the sprayed concrete output comprises primary tunnel lining shells, rock support layers, canal slope protection, and temporary face sealing; post-crack residual strength is evaluated under ASTM C1609/C1609M-19a or ASTM C1399/C1399M-10 only when structural fibre performance is specified, which is outside the intended function of polypropylene monofilament.
In zero-slump precast concrete formulated for continuous extrusion of hollow-core slabs, box culverts, and concrete pipes, the main process conflicts are green strength, edge slump after forming, and die wear; SikaFiber 618 PPM is introduced at 0.6–0.9 kg/m³ in the aggregate-cement dry mix before the water addition point of a truck mixer feeding the extruder hopper, because high-intensity mixing above 120 seconds can separate monofilament bundles and generate static charge that causes clustering on hopper sidewalls. The applicable compliance framework is EN 13369 for common precast concrete rules, ASTM C1116/C1116M-23 for synthetic fibre reinforced concrete, and product-specific standards such as ASTM C76 for reinforced concrete culvert, storm drain, and sewer pipe or EN 1168 for hollow-core slabs; tensile splitting and edge spalling trials under plant conditions typically compare fibre-modified batches against plain zero-slump reference mixes using ASTM C496/C496M at transfer of prestress. Extrusion speed is limited by the stiffening effect of dispersed fibres on the cement paste matrix; production records show that increasing dosage beyond 1.2 kg/m³ decreases extrusion rate by 5–15% and raises extruder motor torque, while 0.6 kg/m³ may not suppress edge tearing in low-paste mixes with water-to-cement ratios near 0.30. The resulting precast inventory includes prestressed hollow-core units, dry-cast concrete pipes, reinforced box culverts, and riser sections; monofilament polypropylene is used not for structural bending capacity but for control of early-age cracking and handling damage before steam curing and yard stocking. Published plant data specific to this fibre configuration and low-paste mix design remains limited; the torque and extrusion-speed deviations are inferred from production records on zero-slump polypropylene monofilament batches rather than universal design values.
Trowel-applied structural and non-structural cementitious repair mortars require green-state shrinkage control during early hydration when they are placed in thin sections over spalled concrete and exposed to rapid drying from surrounding parent material. SikaFiber 618 PPM at 0.3–0.9 kg/m³ is dispersed into the dry blend during the 2–3 minute paddle mixer cycle at 350–500 rpm before the addition of gauging water, with the lower band for feather-edge repairs and the upper band for vertical patch sections exceeding 25 mm thickness. Conformity is assessed under EN 1504-3:2005 for class R3 or R4 mortars where applicable, ASTM C928/C928M for packaged rapid-hardening cementitious repair materials, and EN 14889-2:2006 for polymer fibre quality. The production process involves substrate preparation to a minimum tensile pull-off strength, application by trowel or low-velocity spray, and curing membrane application; improper dosing above 1.2 kg/m³ can produce visible fibre clumps at patch edges and reduce the bond area measured under ASTM C1583/C1583M. Repair geometry classes covered include column edge repairs, soffit repairs, vertical spall reinstatement, and balcony edge build-ups.
In self-compacting concrete for architectural precast facade panels and unitised cladding elements, the main defects are plastic settlement cracking over congested casting features and surface bugholing on form-facing surfaces. SikaFiber 618 PPM is added at 0.6–1.2 kg/m³ during the mixing of self-compacting concrete with a water-to-powder ratio of 0.32–0.40; the fibre is introduced after the aggregates and binder are dry-mixed for 30 seconds, before polycarboxylate superplasticizer is gradually added to reach a slump flow of 650–750 mm under ASTM C1611/C1611M-21. Compliance includes EN 13369, the PCI Quality Control Manual for precast plants where specified in North American exports, ASTM C1116/C1116M-23, and EN 14889-2:2006; production trials commonly evaluate plastic shrinkage with ASTM C1579-21 and hardened flexural toughness with ASTM C1609/C1609M-19a only for documentation, because polypropylene fibres are not a replacement for glass or steel fibre when residual strength is required. The downstream process includes precision mould assembly, release agent application, pump-assisted pouring from a hopper, low-frequency vibration at 50–100 Hz to release entrapped air, and controlled curing at 20–30°C with 95% RH for demoulding after 16–24 hours. End-use components manufactured under this production route include architectural facade panels, punched window units, mullion profiles, and full-thickness cladding up to 200 mm; plant records note that fibre addition reduces surface bleed channels but does not eliminate pinhole bugholes unless mould surface porosity and vibration energy are already optimised.
For bonded and unbonded cementitious screeds placed over concrete slabs or insulation boards, fibre addition at 0.6–1.2 kg/m³ is used to control plastic drying shrinkage during forced-air drying programmes and to reduce surface tearing at high-early-strength binder dosages. The mix is produced in a continuous compulsory mixer with a water dosing tolerance of ±2%, pumped to the floor using a worm or piston screw pump over distances up to 150 m, and finished with a reciprocating screed blade followed by an early-edging roller. Normative references are EN 13813:2002 for screed materials and floor screeds, DIN 18560-1 for floor screeds in building construction, and ASTM F2170-19b for relative-humidity moisture measurement before tile installation. The installed floor systems delivered by this process include heated floor screeds, acoustic floating screeds, and pumped self-smoothing cementitious underlayments up to 50 mm; polypropylene monofilament does not alter foot traffic readiness if the cement chemistry remains within the prescribed air-drying curve.
External render and machine plaster mixes placed on masonry substrates undergo rapid water loss at the surface when applied in thin layers at high air movement; polypropylene fibre dosing at 0.3–0.6 kg/m³ is combined with cellulose ether and air-entraining admixtures in a horizontal shaft mixer before bagging or silo delivery. Conformity uses EN 998-1:2016 for rendering and plastering mortar, ASTM C926 for application of portland cement-based plaster, and EN 14889-2:2006 for polymer fibre. The field process includes substrate wetting, mesh embedding where required, spray application with a rotor-stator pump at 20–40 bar, and wooden-float or plastic-trowel finishing; fibre overdose above 0.9 kg/m³ creates a rough surface texture and increases trowelling resistance. The resulting façade and plaster products include one-coat exterior render, machine-applied basecoat, patchable repair plaster, and decorative stucco-grade façade coating.
Competitive SikaFiber 618 PPM - Monofilament Polypropylene Fiber for Concrete and Mortars prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber 618 PPM is a monofilament polypropylene microsynthetic fiber supplied for secondary reinforcement of concrete and cementitious mortars. The product is based on a polypropylene polymer system and is introduced into the mix to contribute to control of plastic shrinkage cracking, reduction of early-age crack formation, and improved homogenous distribution of microcracking under restrained drying conditions. The numerical designation is consistent with supplier nomenclature for a fiber length of approximately 6 mm and an equivalent diameter near 18 µm, producing a high surface-area-to-volume geometry relative to fibrillated polypropylene fibers. The material is non-corrosive, hydrophobic, and chemically inert in normal cementitious environments, does not absorb mix water, and does not participate in cement hydration chemistry. These characteristics make it suitable for direct addition to ready-mix concrete, precast concrete, slabs-on-grade, screeds, mortars, and wet-process sprayed concrete where early-age crack control is specified as a durability measure under relevant construction standards.
The table below consolidates commonly reported physical and mechanical parameters for polypropylene monofilament microsynthetic fiber in the class represented by SikaFiber 618 PPM. Values are typical bench-level characterizations for the polymer class and should be verified against the manufacturer certificate of analysis, because batch-specific melt extrusion and draw conditions can shift tensile response by up to 10 %. Final compliance is determined by the declared values in the applicable Declaration of Performance under EN 14889-2:2006 and by classification under ASTM C1116/C1116M.
| Parameter | Typical value or classification | Reference method |
|---|---|---|
| Base polymer | Polypropylene homopolymer | Supplier specification |
| Fiber form | Monofilament | Visual / microscopy |
| Length | 6 mm | Supplier dimensional control |
| Equivalent diameter | 18 µm | Optical microscopy |
| Density | 0.91 g/cm³ | ASTM D792 / ISO 1183-1 |
| Tensile strength | 300–400 MPa | ASTM D2256 / ISO 2062 |
| Modulus of elasticity | 3.5–4.0 GPa | ASTM D2256 / ISO 2062 |
| Water absorption | <0.1 % by mass | ASTM D570 |
| Melting point | 160–170 °C | ASTM D3418 / DSC |
| Alkali resistance | No degradation in saturated calcium hydroxide solution | ASTM C1116/C1116M screening |
| Fiber class | Microsynthetic, Class I | EN 14889-2:2006 |
The monofilament form is produced by extrusion and drawing, which aligns polymer chains along the fiber axis. That alignment increases tensile strength relative to unoriented polypropylene film and provides consistent cross-sectional geometry for dispersion calculations. Because the fiber does not absorb water, it does not alter free-water demand by absorption, although it can influence the apparent yield stress and slump response of the mixture through particle interference and increased total surface area. The degree of slump modification is not linear with dosage and is affected by aggregate shape, paste volume, and admixture chemistry.
In ready-mix production, batch-to-batch dispersion variability is the primary processing risk. SikaFiber 618 PPM should be added to the coarse or fine aggregate stream before water addition or introduced into a mixer operating at high-shear speed. Addition of the loose fiber directly onto dry cement or into an idle mixer can create agglomerates that are difficult to separate once wetted. Pan mixers, planetary mixers, and twin-shaft mixers typically require 30–60 s additional mixing after fiber introduction for visual uniformity. Ready-mix truck mixers at low drum rotation may require 5–8 min of full-speed mixing after fiber dosing, depending on batch size and blade condition. The effect on slump can be evaluated under ASTM C143/C143M, with comparative measurements before and after fiber addition. Reported slump reductions for similar monofilament microsynthetics at 0.9 kg/m³ range from 10 mm to 30 mm; published data for this specific configuration is limited, and full-scale plant trials are required to establish dosage-specific adjustment ranges for high-range water-reducing admixtures.
Air content should be monitored under ASTM C231/C231M or ASTM C173/C173M, because fiber addition can alter air-void stabilization in air-entrained mixtures. The change is generally less than 1.0 %, but interaction with synthetic air-entraining admixtures may require re-verification of dosage. Placement and finishing should follow standard practice for fiber-reinforced concrete. Hard troweling of slabs with exposed monofilament fibers can produce surface fuzzing if the concrete is finished too early or too aggressively. Delaying final troweling until bleed water has dissipated and using a low-angled steel blade generally minimizes fiber protrusion.
The function of SikaFiber 618 PPM in plastic shrinkage crack control is primarily geometric: the high count of fine monofilaments per unit volume distributes local tensile strains that develop during surface drying before final set. A dosage of 0.9 kg/m³ for the 6 mm fiber geometry provides on the order of several hundred million fibers per cubic meter, depending on the measured diameter and density. That fiber population reduces the coalescence of shrinkage microcracks into visible cracks under restrained evaporative conditions. The relevant test method is ASTM C1579-21, which uses a restrained slab panel exposed to forced airflow to evaluate plastic shrinkage cracking. In such tests, monofilament polypropylene microsynthetics are typically compared at dosages between 0.6 kg/m³ and 1.8 kg/m³. Crack width and aggregate crack length can be reduced substantially, but the response is sensitive to paste content, slag or silica fume content, air content, curing initiation, and ambient evaporation rate.
The product is not a structural reinforcement substitute. It does not provide post-cracking flexural capacity in the manner of steel fibers or macro-synthetic fibers with a diameter greater than 0.3 mm. Load-carrying capacity after cracking remains dependent on conventional reinforcing steel, welded-wire reinforcement, or structural macrofibers classified under EN 14889-2:2006 Class II or ASTM C1116/C1116M Type III macrofiber. Design calculations for flexural strength may not include SikaFiber 618 PPM unless a specific verified performance model exists in the project specification. Elevated dosages above 1.5 kg/m³ may improve crack control but can cause reductions in workability that require mix redesign and may not be economically justifiable without documented test data.
Plastic shrinkage cracking is strongly influenced by ambient conditions. The American Concrete Institute hot-weather guidance recommends limiting evaporation rate to below 1.0 kg/m²/h for conventional concrete. Monofilament fiber is an auxiliary measure and does not remove the need for fogging, evaporation retarders, damp subgrade preparation, and early curing, especially when air temperature exceeds 30 °C or wind speed exceeds 15 km/h. Without curing, plastic fiber cannot prevent cracking driven by surface tension gradients.
Polypropylene fibers for concrete are available in monofilament and fibrillated forms. Fibrillated fibers form a cross-linked net-like structure during mixing, whereas monofilaments remain as discrete cylindrical filaments. The monofilament form in SikaFiber 618 PPM is selected when surface finish, pumpability, and fine dispersion are more critical than post-crack pullout resistance. Compared with fibrillated polypropylene fibers of similar denier, monofilaments tend to disperse more readily in low-viscosity mortars and self-consolidating concrete, and are less prone to balling at moderate addition rates. The smooth geometric form also reduces visible fiber clustering in troweled surfaces.
The main technical trade-off is reduced anchorage. A single monofilament has no branching to develop mechanical engagement across a crack. Pullout resistance is governed by interfacial friction between the polypropylene surface and cementitious matrix. For this reason, monofilament microsynthetics are not considered for structural crack-widening control in hardened concrete. The product is differentiated from macro-synthetic fibers by diameter and length. Macro-synthetic fibers typically have diameters of 0.3–1.0 mm and lengths of 30–60 mm, and are used at dosages of 3–9 kg/m³ to produce measurable residual flexural strength. SikaFiber 618 PPM is used at lower dosage for early-age behavior and is classified as microsynthetic through the 18 µm diameter value.
| Fiber class | Diameter | Typical dosage | Primary function in concrete | Standard classification |
|---|---|---|---|---|
| Monofilament microsynthetic polypropylene | 18 µm | 0.6–1.8 kg/m³ | Plastic shrinkage crack reduction | EN 14889-2 Class I / ASTM C1116 Type III |
| Fibrillated microsynthetic polypropylene | 15–40 µm equivalent | 0.6–1.8 kg/m³ | Plastic shrinkage control; some composite surface toughness | EN 14889-2 Class I / ASTM C1116 Type III |
| Macro-synthetic polypropylene | 0.3–1.0 mm | 3–9 kg/m³ | Post-crack residual flexural capacity | EN 14889-2 Class II / ASTM C1116 Type III |
| Steel fiber | 0.3–1.3 mm | 20–50 kg/m³ | Toughness, load transfer, shrinkage restraint | EN 14889-1 / ASTM C1116 Type I |
The choice among these fibers is governed by specification language. If the specification requires a minimum residual flexural strength value under EN 14651 or ASTM C1609/C1609M, a microsynthetic monofilament such as SikaFiber 618 PPM is not suitable. If the specification requires crack-width reduction in the first 24 h after casting under ASTM C1579-21, the monofilament class is appropriate. Mixed fiber systems combining microsynthetic and macro-synthetic products may be used, but compatibility must be established through trial batching, because total fiber surface area and water demand can interact unpredictably with air entrainment and high-range water reducer.
For mortars, screeds, and repair materials, the fiber can be added to dry mix formulations or site-mixed products. In dry-mix mortars, pre-blending in a ribbon blender or similar low-shear mixer is required to avoid fiber segregation. Bulk density of the loose fiber is typically low, and handling systems should be designed to avoid entrained air pockets and static cling. Automated dosing equipment with pneumatic transfer may require static grounding and sufficient agitation to maintain free flow. In wet-mix shotcrete, SikaFiber 618 PPM may be introduced at the batch plant rather than at the nozzle, because its fine monofilament form is generally not compatible with nozzle-injection of high concentrations due to clumping risk. The plastic shrinkage benefit in sprayed concrete is secondary to the requirements for early-age curing and surface protection.
Use in concrete containing lithium nitrate admixtures, calcium nitrite corrosion inhibitors, or silica fume slurry does not inherently degrade polypropylene fiber performance, but mix stability must be verified because these admixtures can change plastic viscosity and alter fiber distribution. The fiber itself does not induce corrosion, does not support galvanic cells, and does not contribute to alkali-silica reaction. It is resistant to the alkaline pore solution of concrete, which typically has a pH above 12.5 during early hydration. Long-term chemical degradation of polypropylene in concrete is negligible under normal temperature and humidity conditions, but service temperatures above 80 °C may soften the polymer and reduce mechanical effectiveness.
SikaFiber 618 PPM falls under the scope of EN 14889-2:2006, “Fibres for concrete — Part 2: Polymer fibres — Definitions, specifications and conformity.” Because the equivalent diameter is less than 0.3 mm, the classification is Class I microsynthetic fiber. The standard requires the manufacturer to declare fiber length, diameter, tensile strength, modulus of elasticity, density, and alkali resistance, among other properties. The product must be accompanied by a Declaration of Performance under the Construction Products Regulation to be CE marked for use in concrete. The exact declared values for each batch may vary within the manufacturer’s acceptable tolerance and must be verified against the actual certificate.
Under ASTM C1116/C1116M, the product is classified as a Type III synthetic fiber-reinforced concrete fiber. Type III covers monofilament and fibrillated polypropylene and polyethylene materials that do not meet the strength and stiffness requirements of Type I steel or Type II glass fibers. This classification signals that the fiber may provide crack-control benefits but is not inherently identical to steel or glass in strength or modulus. Testing to ASTM C1579-21 or ASTM C1581/C1581M may be specified by the engineer for plastic shrinkage cracking and restrained shrinkage cracking, respectively.
The product does not require pre-soaking, and moisture content of the fiber is negligible under normal storage. At high relative humidity above 60 %, packaging should remain sealed to prevent condensation on the fiber surface, which can cause flow blockages in automated dispensers. The fiber is combustible; storage near open flame or ignition sources is prohibited. During concrete placement, the polymer fiber does not present the same hazard profile as steel fibers and does not damage pump hoses in the same manner, although static accumulation in dry feeding systems should be controlled.
No attempt should be made to use SikaFiber 618 PPM as a substitute for jointing, air entrainment, structural steel, or proper curing. Incompatible conditions include use in concrete intended for high-temperature refractory service above 80 °C, use in contact with strong oxidizing agents or hydrocarbon solvents, and use as the sole reinforcement in structural elements requiring a minimum post-crack tensile capacity. When applied in slabs with power trowels, the risk of surface fuzzing increases if the blade angle is too high or if finishing occurs while bleed water remains. The product is also not intended for external post-tensioning, anchorage, or stress-transfer applications. Where published test data cannot be located for a particular mix design, a preconstruction mock-up panel under site conditions is required before production concrete is placed.