| HS Code | 609815 |
| Productname | SikaFiber M 5 |
| Producttype | Ultra-fine monofilament polypropylene fiber |
| Material | Polypropylene |
| Fiberform | Monofilament |
| Fiberlength | 5 mm |
| Fiberdiameter | 0.02 mm |
| Density | 0.91 g/cm³ |
| Meltingpoint | 160 °C |
| Ignitionpoint | >300 °C |
| Tensilestrength | >300 MPa |
| Elasticmodulus | >3000 MPa |
| Elongationatbreak | >15% |
| Waterabsorption | Nil |
| Alkaliresistance | Excellent |
| Acidresistance | Excellent |
| Color | White/Natural |
| Dosage | 0.6–1.8 kg/m³ |
| Packaging | 1 kg bag |
| Shelflife | 5 years |
| Storageconditions | Dry, protected from direct sunlight, 5–30 °C |
| Standard | EN 14889-2 |
| Chemicalresistance | Inert to acids and alkalis |
| Thermalconductivity | Low |
| Electricalconductivity | Low |
| Chloridecontent | Nil |
As an accredited SikaFiber M 5 - Ultra-fine Monofilament Polypropylene Fiber for Mortar and Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber M 5 is packaged in 600 g moisture-resistant bags, typically 20 bags per carton (12 kg total). |
| Container Loading (20′ FCL) | 20′ FCL container loading of SikaFiber M 5, ultra-fine monofilament polypropylene fiber for mortar and concrete, securely palletized for export. |
| Shipping | SikaFiber M 5 ships as a non-hazardous, non-regulated solid in moisture-resistant bags or cartons, unitized on shrink-wrapped pallets. Store dry, shaded, and at moderate temperatures. Avoid punctures, contamination, and excessive stacking. Follow local transport regulations and manufacturer’s packaging, handling, and storage guidance. |
| Storage | Store SikaFiber M 5 in its original, unopened packaging in a dry, cool, well-ventilated area, ideally at 5–30°C. Protect from moisture, direct sunlight, extreme heat, and contamination. Keep bags sealed and off the ground to prevent dampness or damage. Avoid contact with solvents, oils, or strong chemicals. Observe shelf life and rotate stock. Use clean, dry handling equipment. |
| Shelf Life | Store in original unopened packaging, cool, dry, protected from sunlight; shelf life approximately 24 months from production date. |
Addition of ultra-fine monofilament polypropylene fibre of the SikaFiber M 5 type at 0.5–1.2 kg/m³ to a C2TE cementitious tile adhesive modifies the fresh mortar’s cohesion and plastic shrinkage crack pattern measured under restrained drying conditions referenced in ASTM C1579-21. The fibre type is classified as a non-structural Class II polymer microfibre under EN 14889-2:2006; the finished adhesive itself is tested for tensile adhesion after water immersion, heat ageing, and freeze-thaw cycles according to EN 12004-2:2017. The upper addition limit is set at 1.2 kg/m³ because higher loadings have produced electrostatic clumping in vertical screw conveyors and visible fibre accumulation on the flight edges of a 65–75° inclined transfer screw at relative humidity above 70%. Industrial dry blending in a twin-shaft paddle mixer of 3 000 kg batch size requires the fibre to be metered after 60–90 s of dry pre-mixing of the cement, 0.1–0.3 mm quartz sand, and redispersible polymer powder; the main mixing step continues for 90–120 s at 40–60 rpm to disperse the monofilaments without fibrillation. A production control screen of 0.5 mm aperture is used on a 500 g aliquot, and retained fibre clusters must remain below 0.05% by mass. The terminal article is a 25 kg valve-bag dry mortar for tile bedding layers from 3 mm to 10 mm thickness, with the fibre phase contributing to plastic shrinkage resistance but not to the structural load path of the cured adhesive layer.
In self-leveling floor underlayments formulated to EN 13813:2002, the introduction of 0.6–1.0 kg/m³ of ultra-fine monofilament polypropylene fibre modifies plastic settlement crack control over heated screed systems when assessed by ASTM C1581/C1581M, but the fibre network also stabilises entrained air bubbles during high-shear mixing as measured by EN 1015-7:1999. At dosages above 0.8 kg/m³, wet density measured by EN 1015-6:1999 has been recorded in plant trials to fall by 2–4%; the resulting pinhole density on a 2 mm top layer can exceed 10–15 per 100 cm² under grazing-light inspection after 24 h. Published data for this specific surface-air interaction in calcium sulfoaluminate-based underlayments remains limited, but the operational boundary is clear: a silicone-modified defoamer dosed at 0.05–0.15% by total powder mass is required when the fibre dosage exceeds 0.8 kg/m³. Production of the dry-mix compound uses a batch ploughshare mixer with an effective volume of 1 500–2 000 kg; the fibre is added after the fine limestone filler and before the final 120–180 s homogenisation phase to prevent fibre abrasion and excessive water demand. The terminal product is a 25 kg bagged self-leveling underlayment applied at 2–20 mm thickness over electrical and hydronic heating systems, with indoor emission control conforming to EMICODE EC1 Plus test requirements.
The use of 0.9–1.5 kg/m³ of ultra-fine PP monofilament in wet-mix shotcrete addresses plastic shrinkage cracking in temporary ground support and rock slope stabilization where steel fibres are not specified for structural toughness. The fibre is classified under EN 14889-2:2006; the sprayed concrete itself is placed in accordance with EN 14487-1:2005 and should not be assigned ductility or energy-absorption values measured by EN 14651:2005+A1:2007, as those values are reserved for steel fibre systems. In a wet-mix batching plant using a twin-shaft forced-action mixer of 2 000 kg rated output, the fibre is introduced into the aggregate stream before the cementitious slurry to reduce fibre balling; the batch is then inspected by pumping a 0.5 m³ trial through a 50 mm double-piston shotcrete pump. Blockages at the nozzle are most commonly observed when fibre dosage exceeds 1.5 kg/m³, when mixing time is shorter than 60 s, or when the aggregate fraction contains flat particles above 8 mm. Fresh-state testing under EN 12350-2:2019 for slump is therefore used with a target consistency of 140–180 mm; a lower slump increases the risk of fibre clumping at the nozzle. The applied layer typically ranges from 50 mm to 150 mm for rock sealing and temporary excavation support, and the fibre’s function is limited to early-age crack width control rather than post-crack flexural reinforcement.
For thin-section precast concrete with element thickness below 40 mm, an addition range of 0.9–1.2 kg/m³ is used to reduce edge cracking during demolding and handling, with crack widths monitored using a 40× optical comparator and recorded as total crack length per element. The mixture is specified under EN 13369:2018 common rules for precast concrete products, with the fibre phase conforming to EN 14889-2:2006 and the concrete matrix achieving the compressive strength class stated by the manufacturer, commonly C30/37 or C40/50 according to EN 206:2013+A2:2021. In a pan mixer of 1 000 kg batch capacity, mixing begins with 30 s of fibre and coarse sand pre-blending before water and cement are introduced; total mixing time is kept between 90 s and 150 s because longer periods do not improve dispersion and may bend the monofilaments. The concrete is placed into steel or polyurethane moulds and compacted with a low-frequency vibrating table at 40–60 Hz for 20–45 s; prolonged vibration causes fibre alignment parallel to the visible surfaces, creating a higher probability of surface fibre protrusion after demolding at 16–24 h. The terminal products include window sills, copings, ventilation blocks, and non-structural cladding panels where crack control under restrained drying outweighs the need for steel reinforcement.
Polypropylene monofilament fibre at a dosage of 0.6–1.5 kg/m³ is incorporated into shrinkage-compensated structural repair mortars conforming to EN 1504-3 Class R4 for concrete repair. The fibre phase is not a substitute for the tensile strength increase provided by the polymer modifier; it reduces early-age crack width under drying conditions at 23 °C and 50% RH when evaluated by ring tests based on ASTM C1581/C1581M. Manufacture of the dry repair mortar is typically carried out in a horizontal single-shaft ploughshare mixer of 1 500–2 000 kg usable volume. The fibre is added after coarse sand and cement have been premixed for 180 s; the subsequent mixing time is limited to 120 s because excessive shear can fibrillate the monofilament and raise water demand by 2–5%. The terminal product is a 20–25 kg bagged R4 repair mortar for concrete spalls, honeycomb repair, and edge rebuilding, with a typical application thickness from 5 mm to 40 mm per layer. At the upper fibre dosage of 1.5 kg/m³, trowel workability increases but the wet density may decrease by up to 3%, and substrate wetting under EN 1542:1999 pull-off testing must be verified independently for each batch.
A polymer-modified basecoat for external thermal insulation composite systems (ETICS) uses 0.5–1.0 kg/m³ of ultra-fine monofilament polypropylene fibre to reduce plastic shrinkage and improve trowel cohesion during embedding of the 160–200 g/m² fibreglass mesh. The basecoat is assessed under ETAG 004:2013 criteria and must meet the render requirements of EN 998-1:2016; the fibre component itself is classified under EN 14889-2:2006. Dry-mix production uses a horizontal paddle mixer where the fibre is fed through a low-speed side port after 3–5 min of base powder premixing, and the final batch requires an additional 60–90 s mixing to avoid visible fibre clusters on the trowel blade. On the jobsite, the dry mortar is mixed with 5.0–6.0 L of water per 25 kg bag and applied as a 3–5 mm bonding and base coat for expanded polystyrene insulation boards. The fibre does not replace the fibreglass mesh reinforcement required by the system holder, nor does it remove the need for mechanical fixings where wind load calculations exceed the adhesive competence of the substrate.
Competitive SikaFiber M 5 - Ultra-fine Monofilament Polypropylene Fiber for Mortar and Concrete prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber M 5 is identified as an ultra-fine monofilament polypropylene fiber for mortar and concrete. The product belongs to EN 14889-2 Class I micro-synthetic polymer fibers, with a nominal cut length of 5 mm encoded in the designation. The polypropylene base resin has a density of approximately 0.91 g/cm³. Under the harmonised European framework, the manufacturer must declare fiber length, equivalent diameter, tensile strength, and the effect on concrete properties through an Initial Type Testing programme. For any specific batch, the lot-specific Declaration of Performance should be read before use, because fiber diameter and tensile strength are controlled within manufacturer tolerances and independent published data for this exact configuration is limited. The fiber is dosed by mass per cubic metre, which means the effective fiber count is inversely related to the filament diameter and directly governs plastic-crack bridging.
Because polypropylene is inherently hydrophobic, the fiber does not absorb mix water. Chloride ion contribution is considered negligible for polypropylene-based fibers, but the current Safety Data Sheet should be checked for coating or handling residues. The melting range of polypropylene is generally 160–170 °C; above this range the filament loses geometric continuity. This thermal limit excludes the product from refractory castables or structural elements expected to operate continuously above 100 °C without project-specific testing. At normal concrete service temperatures below 60 °C, the polymer remains chemically inert in the alkaline cementitious environment and is not susceptible to corrosion. The product does not participate in cement hydration stoichiometry, and its fresh-state influence is primarily rheological rather than chemical.
The distinction is based on filament architecture, aspect ratio, and the standard under which the product is placed on the market. SikaFiber M 5 is supplied as discrete monofilaments, not as a fibrillated sheet or tape that opens under shear. A fibrillated polypropylene micro-fiber begins as a film structure and develops a higher specific surface during mixing; this response is sensitive to mixer energy and may create variable performance if the mixer is worn or undersized. SikaFiber M 5, as a monofilament, enters the mix with its final filament geometry. Steel fibers under EN 14889-1 typically have lengths of 30–60 mm and a density near 7.85 g/cm³; they act as post-crack reinforcement and may be used in structural design through national concrete code annexes. The 5 mm micro-synthetic product does not provide residual flexural strength in the same order as EN 14889-2 Class II macro-synthetic fibers. Its function is concentrated in the first hours after placing, when plastic settlement and capillary pressure control crack initiation.
Because SikaFiber M 5 has a lower tensile modulus than steel, it cannot carry structural loads after a crack has opened. The product should therefore be separated in specifications from steel fibers or structural macro-synthetic fibers. Claims for crack control must be limited to plastic shrinkage and restrained early-age settlement unless hardened-state testing under EN 14651 or an equivalent fracture method is performed. Dose levels typical for mortar and concrete are 0.6–1.0 kg/m³; at these masses, compressive strength changes are normally within the scatter of EN 12390-3 cylinder testing. When the addition is raised to 1.5 kg/m³ for abrasion-resistant toppings, workability loss can appear as a slump reduction of 10–20 mm under EN 12350-2, and the mix must be adjusted rather than simply over-compacted on site.
Production-scale mixing behaviour is controlled by addition point more than by total mixing time. In a twin-shaft compulsory mixer, dry fiber discharged directly onto dry cementitious powder can become trapped in low-shear zones, particularly when the water-cementitious ratio is below 0.35. The preferred sequence is to wet the coarse and fine aggregate first, add SikaFiber M 5, and then introduce the binder. This sequence allows the filaments to distribute through moving aggregate before the paste increases in yield stress. A pan mixer with rotor speed of 20–30 rpm generally requires 60–90 seconds of additional mixing after fiber addition to achieve visual homogeneity. In a truck-mix operation, a prepacked fiber bag should be added at mixing speed, with the drum maintained at 12–18 rpm for a short interval before discharge; the exact interval is a function of drum volume, concrete slump, and blade condition. Where mixer blades are worn or blade-to-liner clearance exceeds acceptable plant limits, fiber balls may appear in the pump hopper or on the screed despite an apparently correct mixing time.
The dominant field failure mode is not chemical degradation but agglomeration. Agglomerated filaments can produce resin-rich balls that are easily mistaken for undispersed dry product. This defect cannot be corrected in the pump line; it must be corrected in the mixing vessel. Reducing the dosage below 1.0 kg/m³ for a single addition, or splitting the dosage between aggregate and sand fractions, is the usual production response. The use of a timed dosing gate, rather than manual bag addition at the rear of the drum, reduces batch-to-batch variance. Where the mix contains polycarboxylate ether superplasticiser, the fiber should be distributed before the final superplasticiser dose; adding both simultaneously can generate local viscosity gradients that slow wetting of the polypropylene surface. Once dispersed, the fiber is stable under continued mixing and does not settle out of the paste.
SikaFiber M 5 is compatible with CEM I, CEM II, CEM III, and calcium aluminate binder systems from a chemical standpoint, subject to mix-specific workability correction. It can be combined with air-entraining admixtures, accelerators, retarders, and high-range water reducers. No electrochemical reaction is expected, but each admixture combination should be verified through fresh-state testing and setting-time measurement under EN 934-1 and EN 934-2 as applicable. When steel fibers conforming to EN 14889-1 are used in the same mix, the micro-synthetic fiber should be added only after the steel fibres have begun to separate. The reverse order allows the fine polypropylene filaments to attach to steel fiber surfaces, reducing the effective fibre count at the slab surface.
| Parameter | Value or classification | Reference / test method |
|---|---|---|
| Fiber class | Micro-synthetic polymer fiber, monofilament | EN 14889-2 |
| Nominal length | 5 mm | Manufacturer Declaration of Performance |
| Density | 0.91 g/cm³ | ISO 1183-1 or equivalent polymer density method |
| CE marking | Harmonised construction product | EN 14889-2 |
| Plastic shrinkage dosage | 0.6–1.0 kg/m³ | Manufacturer technical data sheet |
| Maximum abrasion-topping dosage | Up to 1.5 kg/m³ | Mix validation required |
Plastic shrinkage cracking is initiated when the rate of surface water loss exceeds the bleed rate and the capillary menisci in the pore water impose tensile stress on the fresh matrix. The standard field tool is the evaporation-rate nomograph in ACI 305.1R-14, with inputs of air temperature, concrete temperature, relative humidity, and wind speed. A threshold of 1.0 kg/m²/h is commonly used to require mitigation measures. Polypropylene microfibers do not reduce evaporation; they increase the number of filament bridges across developing microcracks and distribute the tensile demand. ASTM C1579-21 is the appropriate laboratory method for comparing restrained slab panels under a controlled evaporation profile. Published comparative studies for polypropylene microfibers report plastic shrinkage crack area reductions in the range 50–80% relative to unreinforced control slabs, depending on dosage, fiber count, aggregate grading, and mix water content. For SikaFiber M 5, a project-specific trial slab is required to establish the actual reduction because open independent data for this exact product configuration is limited.
The mechanism is more effective when the fiber is present at the upper exposed surface, where plastic cracking initiates. Ultrafine monofilaments increase the number of discrete filaments per kilogram compared with macro-synthetic fibers, permitting effective crack bridging at low mass dosage. The fibers also reduce the phenomenon of bleed-water channelling, but they do not substitute for surface moisture management. ACI 308.1-11 provides curing guidance; when wind speeds exceed 25 km/h or relative humidity falls below 30%, the curing regime must be applied before visible cracking appears. If the evaporation rate exceeds 1.5 kg/m²/h, plastic shrinkage cracks may still form in thin slabs even with microfibers, because the capillary stress development rate can outpace the stress-relieving action of the filaments.
In bonded screeds and repair mortars, the thickness of the section also controls the availability of bleed water. A 10–20 mm repair layer placed over a dry substrate can lose moisture from both the top surface and the substrate interface, producing rapid plastic shrinkage. SikaFiber M 5 at the upper end of the 0.6–1.0 kg/m³ range is often required in such sections, but substrate saturation and curing membrane placement are equally influential. Any specification using SikaFiber M 5 should state the evaporation-rate limit, the dosage, the mixing sequence, and the acceptance criterion for crack width at 24 hours; otherwise field results cannot be evaluated objectively.
| Property | SikaFiber M 5 | Class II macro-synthetic fiber | Steel fiber |
|---|---|---|---|
| Length / diameter class | 5 mm, micro-synthetic | 30–60 mm, >0.3 mm | 30–60 mm, 0.5–1.0 mm |
| Primary role | Plastic shrinkage crack control | Post-crack toughness in ground-supported slabs | Structural or toughness reinforcement per design |
| Standard framework | EN 14889-2 Class I | EN 14889-2 Class II | EN 14889-1 |
Application classes include bonded screeds, self-leveling underlayments, repair mortars, patch mixes, and slab-on-grade concrete where plastic-shrinkage crack width control is required. In dry-mix mortar production, SikaFiber M 5 is pre-blended into the dry powder with continuous or batch mixers; moisture ingress during storage causes fiber-to-particle adhesion and undermines the precision of the final dosage. In wet-batch concrete plants, the preferred equipment is a timed aggregate conveyor or a weigher interface that discharges the fiber after the first water. The product is not intended for structural flexural strengthening, does not replace steel reinforcement in suspended slabs, and should not be used in refractory castables because of the polypropylene melting point. Specifications that attempt to use SikaFiber M 5 for post-crack toughness should be rejected unless validated by EN 14651 or an equivalent beam test.
Before use, the current Declaration of Performance, Safety Data Sheet, and batch certificate should be requested. The EN 14889-2 Declaration of Performance includes the declared values for geometry and mechanical properties, but it does not replace project-specific performance testing. The fiber classification is Class I micro-synthetic because the filament diameter is below 0.3 mm and the length is 5 mm. This class is not evaluated as a structural fiber in the same manner as Class II macro-synthetic or steel fibers. When blended with macro-synthetic fibers, the two fiber classes perform distinct functions and should be listed separately in the mix design and batch records.
For thin slab placements exposed to moving air, the evaporation rate should be recorded and the batch record should include the addition time, mixer type, and mixing speed. Acceptance is based on early-age surface crack inspections at 24 hours, not on structural strength calculation. If fiber balls are detected, the batch record is reviewed for blade condition, addition sequence, and mixing speed before adjusting dosage. These operational controls apply to SikaFiber M 5 in plastic-shrinkage control and are the means by which batch-to-batch variation is judged in production.