| HS Code | 787330 |
| Product Name | SikaFiber Micro-1 - Ultra-fine Anti-Spalling Micro Fiber |
| Material | Polypropylene |
| Fiber Type | Monofilament micro fiber |
| Fiber Length | 6 mm |
| Fiber Diameter | 0.018 mm |
| Aspect Ratio | 333 |
| Density | 0.91 g/cm³ |
| Melting Point | 160 °C |
| Tensile Strength | 350 MPa |
| Elastic Modulus | 3500 MPa |
| Alkali Resistance | Excellent |
| Water Absorption | Nil |
| Recommended Dosage | 0.9 kg/m³ |
| Color | White |
| Packaging | 1 kg bag |
As an accredited SikaFiber Micro-1 - Ultra-fine Anti-Spalling Micro Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber Micro-1 ultra-fine anti-spalling micro fiber comes in 0.6 kg water-soluble bags, supplied 24 bags per carton. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with SikaFiber Micro-1 ultra-fine anti-spalling micro fiber, securely palletized, stretch-wrapped, and braced for safe ocean transport. |
| Shipping | Shipping: SikaFiber Micro-1 is supplied in sealed, moisture-resistant bags or cartons, palletized and shrink-wrapped for secure transport. Handle with care to prevent package damage. Keep dry, away from moisture and excessive heat. Typically non-hazardous; follow local regulations and the SDS. Store in a cool, dry, ventilated area. Do not stack beyond recommended limits. |
| Storage | Store SikaFiber Micro-1 in a cool, dry, well-ventilated area, away from moisture, direct sunlight, heat, and ignition sources. Keep containers tightly closed in original packaging until use. Protect from physical damage; avoid dust generation. Use first-in, first-out stock rotation. Do not store near incompatible materials. Ensure labels remain legible. Follow manufacturer’s instructions and local regulations. |
| Shelf Life | 24 months from date of production when stored properly in undamaged original sealed packaging, dry, at +5°C to +30°C, protected from sunlight. |
Precast concrete segment linings for TBM-driven rail and road tunnels remain the most demanding fire-spalling application for high-strength concrete because the RWS and modified hydrocarbon curves impose peak gas temperatures above 1,200°C within the first 10 minutes, while the dense matrix of a C50/60 or C60/75 mix traps pore-vapour pressure at depths where reinforcement cages and segment joint gaskets are most vulnerable. SikaFiber Micro-1 is a monofilament polypropylene fibre with a nominal diameter of 18 µm, length of 6 mm, specific gravity of 0.91, and melt initiation near 160°C; it is introduced at a nominal addition of 1.5 kg/m³ of concrete for any segment design that requires RWS or hydrocarbon fire validation, with the lower bound of 1.0 kg/m³ accepted only for ISO 834 cellulosic exposure where the tunnel operator has explicitly classified the structure as not subject to hydrocarbon fuel loads. Compliance is anchored to EN 14889-2:2006 for the fibre product standard and its Declaration of Performance under Construction Products Regulation (EU) No 305/2011, while EN 1992-1-2:2004 Section 4.5 defines the spalling assessment for high-strength concrete under hydrocarbon fire. At the precast plant, the fibre is added after coarse aggregate charging and before 80% of the batching water enters a twin-shaft compulsory mixer with paddle speeds of 12–18 rpm; mixing is extended by 45–60 seconds relative to the baseline sequence to disperse the hydrophobic monofilaments without balling. Steam curing is maintained at 55–70°C, which is far below the polymer melt threshold and therefore does not collapse the future melt-percolation network. Finished components are tapered or universal segment rings with unit masses in the range of 4–10 tonnes, multiple radial and circumferential joint faces, and EPDM gaskets; each assembled ring contains between five and nine segments and forms the permanent primary lining of a bored tunnel.
For columns with characteristic cylinder strength C70/85 to C100/115 and silica fume additions of 5–10% by mass of cement, the severe spalling risk under ASTM E119-20 cellulosic exposure arises because capillary porosity is reduced below the threshold required for passive vapour escape, and the mix water/cementitious ratio is often below 0.30. SikaFiber Micro-1 addition is typically bracketed at 1.5–2.0 kg/m³, with 1.5 kg/m³ specified for C70/85 to C85/95 and 2.0 kg/m³ reserved for C90/105 to C100/115 core concrete after confirmation in a full-scale furnace test. The upper limit is governed not by fibre performance but by fresh concrete rheology: at 2.0 kg/m³ the additional hydrophobic fibre surface can alter plastic viscosity, an effect that is measurable in ICAR rheometer testing as a shift in relative plastic viscosity, though published data for this specific mix configuration is limited. Compliance is anchored to ACI 216.1-14 for fire resistance, EN 1992-1-2:2004 Section 4.5 for spalling prediction, and ISO 834-1:1999 for thermal exposure; column specimens are conditioned for 90 days before furnace testing because spalling tendency continues to increase as the matrix hydrates. In production, the fibre is batched at the ready-mix plant through the aggregate charging belt or directly into a twin-shaft mixer after the high-range water reducer has dispersed; transit mixing is limited to 25–30 revolutions at 8–12 rpm before pumping, and the concrete is placed with a stationary boom pump to avoid free-fall segregation. The finished elements are reinforced concrete columns and shear walls in high-rise frames, typically specified for R120 or R180 fire resistance classes; the microfibre does not replace the required concrete cover or transverse steel reinforcement.
Because wet-mix shotcrete linings in traffic and mining tunnels rely on an accelerated stiffening matrix that often contains 4–8% silica fume and a water/cementitious ratio between 0.40 and 0.48, this composition still triggers spalling under RWS fire when the sprayed concrete is placed in layers of 50–120 mm and the interface between passes traps densified cement paste. SikaFiber Micro-1 is dosed at 1.5–2.0 kg/m³ in the base mix at the batching plant, with the higher value applied when the design fire is a hydrocarbon or RWS curve and the sprayed section exceeds 150 mm. The principal process conflict is not mixing but conveying: wet-mix shotcrete machines deliver the fibre-bearing mix to the nozzle through a piston pump and a 50–65 mm internal diameter delivery line; the low fibre mass and high aspect ratio do not block the line when the aggregate size is limited to 8 mm, but fibre distribution can be altered by the air injection pattern at the nozzle. Spraying operators therefore run a pre-production spray panel test in accordance with EN 14488-2 to verify in-place fibre content after rebound, because the rebound fraction may be enriched with coarse aggregate while fibre loss remains below 5% under correct nozzle angle. The compliance framework includes EN 14487-1:2005 for sprayed concrete specification and EN 1992-1-2:2004 Section 4.5 for spalling; RWS or ISO 834-1:1999 curves are selected by the tunnel authority. Finished products are permanent primary linings, often 100–200 mm thick, working with rock bolts and lattice girders; the microfibre is not a substitute for conventional reinforcement or for structural macrofibres in high-deformation ground.
| Standard or code | Relevant provision | Application context |
|---|---|---|
| EN 14889-2:2006 | Polymer fibres for structural concrete; Declaration of Performance under CPR 305/2011 | All structural concrete containing SikaFiber Micro-1 |
| EN 1992-1-2:2004 | Section 4.5 — spalling assessment for high-strength concrete | Precast segments, columns, slabs, shotcrete |
| EN 1363-2:1999 | Hydrocarbon temperature-time curve | Tunnel and petrochemical fire scenarios |
| ISO 834-1:1999 | Cellulosic reference curve | Above-ground structural elements |
| RWS curve | Rijkswaterstaat tunnel fire loading | Bored tunnel concrete linings |
| ASTM E119-20 | Fire endurance of concrete members | High-strength columns in North American projects |
| EN 14487-1:2005 | Sprayed concrete specification | Wet-mix shotcrete linings |
| NFPA 502 | Road tunnel fire protection requirements | Traffic tunnel concrete |
| API RP 2218 | Fireproofing practices in hydrocarbon processing facilities | Petrochemical bund walls and process plinths |
When fire-rated precast cladding panels are produced for underground stations, car park decks, and protected shafts, the concrete strength class is generally C40/50 to C55/67; such panels can still suffer spalling under the ISO 834-1:1999 cellulosic fire curve because the elements are often dried to an equilibrium moisture content below 3% before fire testing and the aggregate type may include calcareous particles that destabilise at elevated temperatures. SikaFiber Micro-1 is incorporated at 1.0–1.2 kg/m³, which is at the lower end of the anti-spalling dosage range because the matrix is less impermeable than C80/95 concrete and the required spalling protection period is usually 60–120 minutes rather than the 120–180 minutes typical in tunnel structures. The manufacturing sequence in precast works uses a planetary or pan mixer with a mixing capacity of 0.5–2.0 m³; after mixing, the fibre-bearing concrete is poured into steel or timber moulds and compacted with a vibrating table operating at 40–60 Hz for 30–60 seconds. Steam curing is controlled at 55–70°C and the panels are not demoulded until the core temperature falls below 30°C, which prevents thermal cracking that could compromise the fire test. The terminal products are nominally 100–150 mm thick precast concrete wall panels and box culvert top slabs, classified in accordance with EN 13501-2 as REI 60 to REI 180 depending on the project fire strategy and occupancy load.
| Application | Fire exposure reference | Concrete strength class | Typical addition rate |
|---|---|---|---|
| Precast TBM tunnel segments | RWS / EN 1363-2:1999 hydrocarbon | C50/60–C60/75 | 1.0–1.5 kg/m³ |
| Silica-fume high-strength columns | ASTM E119-20 / ISO 834-1:1999 | C70/85–C100/115 | 1.5–2.0 kg/m³ |
| Wet-mix shotcrete linings | RWS / ISO 834-1:1999 | C30/37–C45/55 | 1.5–2.0 kg/m³ |
| Fire-rated precast panels | ISO 834-1:1999 | C40/50–C55/67 | 1.0–1.2 kg/m³ |
| Cut-and-cover tunnel slabs | RWS / EN 1363-2:1999 | C50/60–C55/67 | 1.2–1.5 kg/m³ |
| Petrochemical bund walls | EN 1363-2:1999 / API RP 2218 | C30/37–C45/55 | 1.5–2.0 kg/m³ |
Cut-and-cover tunnel roof slabs differ from bored tunnel segments because the structural element is restrained against thermal expansion by adjacent walls and soil overburden, a condition that magnifies the compressive stresses driving explosive spalling under hydrocarbon fire exposure. The relevant thermal actions are defined by EN 1991-1-2:2002 for the hydrocarbon curve and by the RWS curve, while EN 1363-2:1999 specifies the furnace control procedure. For cast-in-place slabs with characteristic strength C50/60 or C55/67, SikaFiber Micro-1 is added at 1.5 kg/m³; the rate is reduced to 1.2 kg/m³ only where the slab thickness exceeds 500 mm and drainage of pore vapour is demonstrably improved by limestone aggregate grading. The production process at the site batching plant uses a twin-shaft compulsory mixer and then a truck mixer for delivery; the concrete is pumped through a 125 mm boom line into the slab formwork and compacted with poker vibrators spaced 400–500 mm apart. The critical operational boundary is the avoidance of water addition at the pump hopper, because any increase in water/cementitious ratio above the mix design value will negate the fire test validation and alter the melt-channel distribution. The finished component is a monolithic cut-and-cover roof slab, typically 400–800 mm thick, covered with waterproofing and ballast; the fire protection strategy may require only the soffit to meet a two-hour hydrocarbon fire endurance.
At petrochemical storage and transfer facilities, concrete dike and bund walls are exposed to pool fires that can reach heat fluxes of 150 kW/m² and follow the EN 1363-2:1999 hydrocarbon curve, while the cross-sectional thickness is often limited to 200–300 mm, so spalling can compromise environmental containment within the first 30 minutes. SikaFiber Micro-1 is specified at 1.5–2.0 kg/m³ in cast-in-place concrete with characteristic strength C30/37 to C45/55, with the upper dosage applied where the wall face is unprotected and the bund area exceeds 100 m². The production method uses formwork cast-in-place placement with a conventional skip or pump; because the walls are often constructed in hot coastal environments, the concrete is kept below 30°C at placement and the microfibre is protected from direct sunlight during bag storage, as prolonged UV exposure can degrade the polypropylene surface and alter fibre dispersion. Compliance references include EN 1992-1-2:2004 Section 4.5 for spalling, EN 1363-2:1999 for hydrocarbon fire testing, and API RP 2218 for fireproofing of hydrocarbon processing structures where applicable; the fibre is not a replacement for passive fire protection coatings on steel columns or for emergency spill collection design. The terminal products are containment bund walls, process structure plinths, and transformer blast walls; the anti-spalling function is combined with conventional steel reinforcement and, where required, a surface coating system.
Competitive SikaFiber Micro-1 - Ultra-fine Anti-Spalling Micro Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Identification of the product as SikaFiber Micro-1 – Ultra-fine Anti-Spalling Micro Fiber establishes its position as a synthetic monofilament addition for concrete matrices that require passive fire protection against moisture-induced explosive spalling. The model designation Micro-1 distinguishes an ultra-fine filament geometry intended to disperse into discrete fibres under standard concrete mixing energy. In high-strength concretes with water-to-cement ratios at or below 0.40 and compressive strengths exceeding 60 MPa, the cement paste densifies beyond the point at which capillary percolation can relieve internal vapour pressure during rapid heating. The product is therefore specified where fire exposure is defined by the hydrocarbon curve, RWS curve, or modified HCM curve, and where concrete cover to reinforcement is governed by structural fire design rather than ambient-temperature durability alone.
Specifiers typically invoke this material in tunnel linings, cast-in-place columns, precast segmental liners, and high-rise core walls where spalling of the concrete section could expose reinforcement to temperatures above the critical 500 °C threshold for yield strength loss. The product is added at the batching plant and is compatible with polycarboxylate-ether superplasticizers, air-entraining admixtures, silica fume, fly ash, and ground-granulated blast-furnace slag systems. No additional water demand is introduced when the fibre is dosed correctly, and the as-delivered collated bundles require only the mechanical shearing and impact action of a compulsory mixer to separate into monofilaments. The function of the fibre is physical, not chemical: it does not react with hydration products, does not alter the stoichiometry of cement hydration, and does not contribute to the pore solution chemistry.
At ambient temperature, an ultra-fine polypropylene microfibre is hydrophobic and chemically inert in the alkaline pore solution. During a fire, the cement matrix undergoes differential thermal expansion, free and adsorbed water desorbs, and capillary water flashes to steam. In a dense concrete with permeability below roughly 10-16 m² to 10-17 m², the steam front cannot migrate toward the exposed surface quickly enough; local pore pressure rises at a rate governed by the heating curve and the moisture content of the concrete. When the polypropylene filament reaches its melting range, approximately 160 °C to 170 °C, it melts and leaves behind an empty channel. Because ultra-fine fibres are distributed at high filament counts per unit volume, these channels form a continuous network once the dosage reaches the critical percolation threshold. The result is a temporary permeability increase in the heated zone that allows vapour to escape before the tensile stress exceeds the hot tensile strength of the concrete.
The mechanism is thermal and geometrical, not hydraulic at ambient temperature. The fibre does not perform as a capillary wick prior to melting; its presence contributes little to moisture transport during normal service. After melting, the channels are microscale, and the residual polymer may undergo oxidative decomposition at higher temperatures rather than block the channels. The fibre length, diameter, and dosage must be selected together because percolation depends on the number of individual filaments per cubic metre, not on fibre cross-section alone. If the fibres are too coarse or the dosage too low, the channel network remains discontinuous and vapour pressure is not relieved. If the fibres are too long at a given workability class, dispersion becomes non-uniform and localised spalling may still occur in fibre-poor zones.
Percolation threshold calculations for this class of fibre can be approximated by the product of fibre volume fraction and aspect ratio, but direct percolation is not the only requirement. The melt-induced channel must remain open long enough for vapour to escape. For this polymer class, melt viscosity is approximately 102 Pa·s to 103 Pa·s at the melting point, which is sufficiently low for the melt to coalesce on aggregate surfaces rather than fill the channel. At temperatures above 350 °C, polypropylene thermally decomposes through chain scission and volatilisation; the reaction is endothermic and produces low-molecular-weight hydrocarbons, but the heat absorption is negligible compared with the thermal mass of the concrete. Therefore, the anti-spalling function is attributed to the physical channel network, not to any chemical heat sink effect.
The supplied grade is routinely characterized by a filament diameter in the ultra-fine class below 30 µm, a fibre length in the 6 mm to 12 mm range depending on batch configuration, a polymer density of approximately 0.91 g/cm³, and a melt point near 160 °C. The base polymer is a high-purity polypropylene with no chloride content, and the fibre is non-corrosive to steel reinforcement. Because the product is hydrophobic, water absorption is lower than 0.1% by mass. The fibre count per kilogram for an 18 µm by 6 mm monofilament is on the order of 7.2×108, which illustrates why even a dosage of 1 kg/m³ can place millions of potential pressure-relief channels within a cubic metre of concrete. Published batch certificate values for this specific product should be obtained from the manufacturer for the actual lot, because dimensional tolerances and melt-flow characteristics can vary between production campaigns.
Dosage is the primary variable controlling anti-spalling efficacy. In project specifications, the addition rate is generally selected between 0.9 kg/m³ and 2.0 kg/m³ for concretes with a maximum aggregate size of 20 mm and a compressive strength class above C60/75. The lower value is often adequate under the ISO 834-1 cellulosic curve for moderately dense concrete with residual moisture below 3% by mass. The upper value is frequently required under the RWS or HCM hydrocarbon curves, where heating rates of 200 °C/min can occur in the first minutes and where concrete moisture content may exceed 4% due to curing conditions or groundwater contact. Above 2.0 kg/m³, the fibre volume fraction begins to affect fresh-state rheology: the increased surface area of the fibres absorbs a portion of the paste film and can reduce the slump flow of self-compacting concrete by 50 mm to 150 mm depending on the superplasticizer dosage and mixing sequence. Below 0.9 kg/m³, the linear density of fibres may not be sufficient to create percolation, particularly in concretes with a paste volume below 300 L/m³.
Specifiers should not transfer dosage values between different fire curves without verification. A concrete that passes a 120-minute ISO 834-1 spalling test at 1.0 kg/m³ may exhibit explosive spalling under a 30-minute RWS test if the same moisture condition is retained. The relevant moisture threshold is not the free-water content of the fresh concrete but the moisture state in the cover zone at the time of fire. Pre-drying of test specimens or real structures at relative humidity above 60% for extended periods can produce conservative test results; conversely, testing a dry specimen can mask insufficient dosage. Validation should therefore include conditioning according to the test standard and measurement of internal moisture in the cover zone. Published independent data for this specific fibre configuration under all fire curves is limited; therefore, project-specific testing remains the only reliable basis for dosage confirmation.
Moisture content in the cover zone can be measured by destructive gravimetric methods on drilled cores or by relative humidity sensors cast into the concrete. In precast segments cured by elevated temperatures, moisture content may be lower than 2% at the time of fire, which reduces the required dosage but does not eliminate spalling risk. In cast-in-place tunnel linings protected from drying by formwork and high ambient humidity, the moisture content can remain above 4% for years. The fire protection specification must therefore account for the long-term moisture state, not only the water-to-cement ratio. The presence of silica fume at 8% to 10% by mass of cementitious material lowers the permeability and can increase both strength and spalling susceptibility; fibre dosage may need to be raised toward the upper bound under these conditions.
The fibre is normally added to the aggregate fraction before cement or after the batching water, depending on mixer type. In twin-shaft compulsory mixers with paddle geometries intended for high-intensity mixing, the fibre bundles are broken by shear against the aggregate; a post-fibre wet mixing time of 4 minutes to 5 minutes is typical to achieve monofilament separation. In planetary or pan mixers, the fibre should be added as a continuous stream over the aggregate surface rather than as a single mass. Pneumatic dosing systems should be set to avoid blow-back from fines and to prevent the fibre from accumulating on the mixer walls. Batch-to-batch variance in concrete plants with worn scraper blades or insufficient mixing intensity has been observed as fibre balling at the centre of the mixer, particularly when the entire bag is introduced in less than 10 seconds. Fresh concrete control tests should include slump or slump-flow measurement by EN 12350-2, air content by EN 12350-7, and washed-out fibre distribution verification when spalling resistance is critical. The addition of the fibre does not replace the need for standard curing; however, it may reduce early-age plastic shrinkage cracking in slabs and liners when judged by ASTM C1579.
At the production scale, fibre feeding through automatic dosing equipment should be verified against a mass-flow check. Fibre loss through dust extraction systems in central mix plants can be significant if the fibre is added as a dry component with no aggregate coverage. A mass balance check on the first three batches should compare the as-batched fibre mass with the recovered fibre count from washed-out fresh concrete. Discrepancies above 10% indicate fibre segregation or loss and require adjustment of the addition sequence or mixer venting. When fibres are added by whole-bag manual charging, the total mix time after fibre addition should be extended by at least 30 seconds beyond the standard programme to compensate for non-continuous addition.
The same ultra-fine monofilaments that provide post-melt permeability channels also contribute to the suppression of plastic shrinkage cracking in the first 24 hours after placement. The fibre does not increase the flexural toughness of hardened concrete in the sense of EN 14651 or ASTM C1609 because the filaments are too short and too flexible to bridge macro-cracks after the matrix has fractured. Therefore, the product is not interchangeable with steel macrofibres, polypropylene macrofibres, or structural fibres that are specified to provide post-crack residual strength for structural design. A comparison is provided in Table 1.
| Parameter | SikaFiber Micro-1 / ultra-fine PP | Standard PP microfiber | Steel macrofiber | PVA microfiber |
|---|---|---|---|---|
| Material | Monofilament polypropylene | Monofilament or fibrillated polypropylene | Cold-drawn steel wire | Polyvinyl alcohol |
| Diameter | sub-30 µm | 18 µm–30 µm | 0.5 mm–1.0 mm | 27 µm–40 µm |
| Length | 6 mm–12 mm | 6 mm–12 mm | 30 mm–60 mm | 6 mm–12 mm |
| Density | 0.91 g/cm³ | 0.91 g/cm³ | 7.85 g/cm³ | 1.30 g/cm³ |
| Tensile strength | 300 MPa–600 MPa | 300 MPa–600 MPa | 800 MPa–1200 MPa | 900 MPa–1600 MPa |
| Elastic modulus | 3.5 GPa–4.0 GPa | 3.5 GPa–4.0 GPa | 200 GPa | 25 GPa–40 GPa |
| Primary function | Anti-spalling and plastic shrinkage control | Plastic shrinkage control | Post-crack residual strength and crack-width control | Plastic shrinkage and micro-crack bridging |
| Relevant standard | EN 14889-2:2006; ASTM C1116/C1116M Type III | EN 14889-2:2006; ASTM C1116/C1116M Type III | EN 14889-1:2006; ASTM A820/A820M | EN 14889-2:2006; ASTM C1116/C1116M |
The comparison highlights the central distinction: ultra-fine polypropylene microfibres function as a sacrificial pressure-relief medium under thermal load, whereas macrofibres and steel fibres function as mechanical inclusions that maintain load transfer across cracked sections. A specification that confuses these roles can produce a concrete that passes a flexural toughness test but still spalls under fire, or a concrete that resists fire-induced spalling but fails the required structural residual strength criterion. The two functions are not mutually exclusive, but they cannot be assumed to be interchangeable simply because both materials are called fibres.
Operational boundaries are defined by the fibre geometry and the concrete matrix. The product does not compensate for insufficient cover, poor curing, or inadequate aggregate interlock. It is not a fireproofing material and does not reduce the thermal conductivity of the concrete section. It should not be specified as the sole measure for structural fire protection where spalling is caused by load-induced cracking rather than moisture-driven pore pressure. In concretes with a maximum aggregate size above 32 mm, the fibres tend to follow the paste fraction and may not distribute uniformly through the full section unless the paste volume is increased or the aggregate grading is adjusted. The fibre should be stored in original bags away from sources of ignition and prolonged exposure to ultraviolet light; opened bags should be resealed and protected from condensation in high relative humidity environments above 75%. No chloride contribution is present, but the product is not a rust inhibitor and does not replace corrosion-resistant mix design measures in chloride-bearing service environments.
Product conformity for polymer fibres for concrete is assessed under EN 14889-2:2006, which defines requirements for geometry, tensile strength, alkali resistance, and effect on concrete consistency. The product class falls within fibres for non-structural use, and the manufacturer’s declaration should list the specific fibre length, diameter, and dosage for each batch. When the product is used in fire-resistant concrete, the applicable fire test standard may be EN 1363-2:1999 for element testing, with the heating curve selected from ISO 834-1, RWS, or HCM according to the project. No single fibre dosage can be considered universally validated across all concrete mix designs, and the fire engineering report should be based on full-scale or intermediate-scale spalling tests rather than on fibre dosage alone.