| HS Code | 510159 |
| Product Name | SikaFiber Monofilament-12 - Micro Monofilament Fiber |
| Manufacturer | Sika |
| Product Type | Micro monofilament fiber |
| Material | 100% polypropylene |
| Fiber Type | Monofilament |
| Fiber Length | 12 mm |
| Fiber Diameter | 18 µm |
| Aspect Ratio | 667 |
| Specific Gravity | 0.91 |
| Tensile Strength | ≥300 MPa |
| Elastic Modulus | ≥3000 MPa |
| Melting Point | 160–170 °C |
| Ignition Point | >400 °C |
| Alkali Resistance | High |
| Acid Resistance | High |
| Water Absorption | Nil |
| Recommended Dosage | 0.6–1.8 kg/m³ |
| Packaging | 0.6 kg bags |
| Color | Natural/white |
| Shelf Life | 24 months |
As an accredited SikaFiber Monofilament-12 - Micro Monofilament Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber Monofilament-12 micro monofilament fiber is supplied in 600 g bags, 20 bags per carton, totaling 12 kg. |
| Container Loading (20′ FCL) | Non-hazardous SikaFiber Monofilament-12 micro monofilament fiber, palletized in original packaging, shrink-wrapped, dry, secured, evenly distributed in 20′ FCL for transport. |
| Shipping | SikaFiber Monofilament-12 is typically non-hazardous and not regulated for transport by ADR, IMDG, or IATA. It ships as general cargo in moisture-resistant bags or cartons on pallets. Store dry at moderate temperatures, away from moisture and direct sunlight. No special shipping labels or placards required. Handle with normal industrial care. |
| Storage | Store SikaFiber Monofilament-12 in its original, unopened packaging in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, moisture, and incompatible materials. Keep containers closed, protect from physical damage, contamination, and dust. Store at ambient temperature, avoid extreme temperatures, use first-in, first-out rotation, and follow manufacturer shelf-life guidance plus local regulations and the Safety Data Sheet. |
| Shelf Life | Shelf life is 24 months from production when stored in unopened original packaging, dry, protected from moisture and direct sunlight. |
Large-area ground-supported slabs placed by laser screed receive SikaFiber Monofilament-12 at a dosage between 0.6 kg/m³ and 0.9 kg/m³ before the final third of batch water is metered into a twin-shaft counter-current mixer. The charging sequence is set to avoid fibre accumulation on the underside of the mixer cover: coarse aggregate is introduced first, then the monofilament, then the cementitious binder and remaining water. At a target slump of 150 mm to 180 mm measured per ASTM C143/C143M-20, the addition of 0.9 kg/m³ is observed to reduce slump by 10 mm to 20 mm on production batches; the mix is corrected with a polycarboxylate ether superplasticizer at 0.4% to 0.6% by cement weight. Restrained shrinkage testing per ASTM C1581/C1581M-18a on companion mortar shows delayed crack onset relative to an unmodified reference, although published data for this specific configuration is limited regarding long-term curling. Power-trowel finishing after the bleed-water sheen does not produce surface fuzz at 0.6 kg/m³; at 0.9 kg/m³, delayed final trowelling can expose occasional monofilament ends. The finished element is an internal floor slab for logistics buildings, light manufacturing halls, and automotive storage facilities where early-age crack control within the first 6 h after placement is the controlling requirement. The fibre does not alter saw-cut spacing and is not a substitute for structural reinforcement or dowel load transfer at construction joints.
In thin-section precast façades with wall thickness between 40 mm and 80 mm, SikaFiber Monofilament-12 is dispersed into a self-compacting concrete matrix at 0.5 kg/m³ to 0.8 kg/m³. The batching sequence in a high-energy pan mixer is reversed relative to ordinary practice: the fibre is introduced after the polycarboxylate superplasticizer has been fully dispersed in the mixing water, because early fibre charging in a low-water self-compacting mix can create agglomerates that interrupt the formwork vibration response. Slump flow measured per EN 12350-8:2019 decreases from 650 mm to 580 mm at 0.8 kg/m³; the reduction is compensated by increasing superplasticizer dosage by no more than 0.05% of cement weight. Demoulding strengths at 16 h are not significantly reduced at fibre dosages up to 0.8 kg/m³, based on cube compressive strength tested per EN 12390-3:2019. The terminal component is an architectural cladding panel, modular fence element, or precast screen wall where crack width during formwork release and early ambient curing is the critical acceptance criterion. For acid-etched or polished façade surfaces, a trial panel is required because monofilament ends can appear as surface stipple when the face is ground or polished to a depth greater than 1 mm. The fibre is supplied under EN 14889-2:2006 conformity assessment and is not intended to replace steel reinforcement in load-bearing precast elements.
| Formulation context | Fibre dosage | Observed consistency or performance response | Test method |
|---|---|---|---|
| Industrial slab-on-grade, laser-screeded | 0.6–0.9 kg/m³ | Slump reduction 10–20 mm; restrained crack onset delayed | ASTM C143/C143M-20; ASTM C1581/C1581M-18a |
| Thin precast façade, self-compacting concrete | 0.5–0.8 kg/m³ | Slump flow reduction from 650 mm to 580 mm; 16 h demoulding strength unchanged | EN 12350-8:2019; EN 12390-3:2019 |
| Wet-mix shotcrete | 1.0–1.8 kg/m³ | Rebound 8–15% at 1.0–1.5 m nozzle distance; pump pressure oscillation ±5 bar above 2.0 kg/m³ | EN 14488-2:2006; vertical test panel rebound |
| Self-smoothing underlayment | 0.3–0.5 kg/m³ | Flow spread reduced 10–15 mm | EN 12350-5:2019 |
| Repair mortar placed overhead | 0.2–0.5 kg/m³ | Vertical slip ≤2 mm at 20 mm thickness | EN 1504-3:2006; inclined plate sag test |
| High-strength pumped concrete | 0.9–1.2 kg/m³ | Strength reduction 3–5% at 1.2 kg/m³ when mixing exceeds 10 min | ASTM C1698-19; EN 12390-3:2019 |
Where wet-mix shotcrete is specified for rock slope stabilization and temporary tunnel starter walls, SikaFiber Monofilament-12 is batched into the carrier concrete at 1.0 kg/m³ to 1.8 kg/m³. The aggregate grading is modified to a maximum nominal size of 8 mm to prevent fibre hang-up at the nozzle body; cement content is held between 380 kg/m³ and 425 kg/m³, and the water-cement ratio is restricted to 0.42 to 0.48. The mixed material is pumped through a 50 mm flexible conveying hose at pump pressures between 30 bar and 60 bar; at fibre dosages above 2.0 kg/m³, pressure oscillations of ±5 bar are observed at the pump gauge and rebound on a vertical panel can exceed 20%. Field rebound measured on a vertical test panel remains between 8% and 15% when nozzle distance is maintained at 1.0 m to 1.5 m and air pressure is set at 4 bar to 5 bar. Compressive strength specimens are extracted from shotcrete test panels after 7 d and 28 d and tested per EN 14488-2:2006. The installed product is a temporary or permanent facing shell on rock slopes, tunnel breakout zones, and swimming pool shells where early-age crack reduction and placement speed are specified. SikaFiber Monofilament-12 does not replace welded-wire mesh in permanent load-bearing tunnel linings unless the responsible engineer has accepted an alternative design based on applicable sprayed concrete standards such as EN 14487-1.
Flowable cementitious underlayment formulations produced for renovation over existing concrete receive SikaFiber Monofilament-12 as a dry pre-blended component at 0.3 kg/m³ to 0.5 kg/m³. The premix is added to a continuous high-shear corundum rotor mixer before the latex or powdered acrylic redispersible polymer is introduced. Adding the fibre directly to the mixing vortex without dry pre-blending produces mat formation on the paddle shaft and can reduce discharge throughput by up to 20%. Flow characteristics are assessed on a flow table per EN 12350-5:2019 with a target spread of 240 mm to 260 mm; at 0.5 kg/m³, the spread is reduced by 10 mm to 15 mm, requiring an additional 0.5% to 1.0% mixing water by dry premix weight. The installed layer is applied from 3 mm to 15 mm over old concrete or screed substrates. The fibre functions as an early-age crack control addition under vinyl, polyurethane, and trowelled epoxy floor coverings where shrinkage stress builds at door openings and under forced ventilation. Doses above 0.8 kg/m³ are not recommended for layers thinner than 5 mm because visible monofilament ends can remain after final smoothing. Site-dosed fibre is not recommended for self-smoothing systems because continuous mixing and emplacement equipment has no secondary dispersion stage.
In polymer-modified cementitious repair mortars conforming to EN 1504-3 Class R3 or R4, SikaFiber Monofilament-12 is added at 0.2 kg/m³ to 0.5 kg/m³ when the repair layer is specified for a minimum thickness of 15 mm. The mortar is prepared in a low-speed paddle mixer, not in a high-shear plaster mixer, to prevent fibre rupture and excessive plastic viscosity build-up. After mixing for 3 min, the mortar is left to stand for 2 min and remixed for 30 s; this sequence is critical because the fibre network develops shear-dependent gelation that improves overhead adhesion only after the polymer phase has released entrained air. Sag resistance is evaluated on an inclined plate with a maximum vertical slip of 2 mm at 20 mm thickness. The terminal repair is applied to soffit concrete and balcony edges where carbonated or chloride-contaminated substrate has been removed by hydro-demolition. For overhead repair layers thinner than 12 mm, the fibre length approaches the placement thickness and protruding monofilament ends can appear after trowelling; in such cases a shorter fibre or no fibre is specified. The fibre does not replace corrosion inhibitors, anti-carbonation coatings, or structural reinforcement in the repaired element.
When high-strength core-wall concrete is pumped at water-cement ratios below 0.40 with silica fume replacement between 5% and 10%, autogenous shrinkage strain measured per ASTM C1698-19 can exceed 400 microstrain within 7 d. SikaFiber Monofilament-12 is incorporated at 0.9 kg/m³ to 1.2 kg/m³ at the batch plant, after the silica fume slurry and before the final polycarboxylate ether dose, to prevent agglomeration in the high-shear mixer. The concrete is discharged into a trailer pump with a 125 mm delivery line and placed through a boom; pump pressure at the hopper is recorded between 80 bar and 140 bar, with occasional spikes of 10 bar at the upper fibre limit. These pressure spikes correspond to segregation zones near the piston face and are eliminated by increasing the initial superplasticizer dosage by 0.1% by binder mass rather than by adding water. Cylinder compressive strength at 28 d per EN 12390-3:2019 is unchanged at 0.9 kg/m³; at 1.2 kg/m³, a strength reduction of 3% to 5% can occur if mixing time exceeds 10 min due to air entrapment on the fibre surface. The terminal component is load-bearing pump concrete for columns, shear walls, and transfer slabs where both early-age crack reduction and pump-line stability are mandatory. SikaFiber Monofilament-12 is not a substitute for wet curing, internal curing, or shrinkage-compensating admixtures in mass concrete sections greater than 1 m thickness.
Competitive SikaFiber Monofilament-12 - Micro Monofilament Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber Monofilament-12 is an extruded polypropylene micro-monofilament supplied for secondary reinforcement of cementitious materials. The product is designated by its nominal length of 12 mm and a micro-grade filament diameter of 0.22 mm; the base resin has a specific gravity of 0.91 g/cm³ as declared in the manufacturer’s technical data sheet. Classification under EN 14889-2:2006 places the fibre within the polymer micro-fibre category for early-age crack control. It is supplied in pre-weighed dispersing bags of 0.9 kg for direct charging into central mixers, truck mixers, pan mixers, and continuous concrete production lines. The calculated fibre count based on the nominal cylindrical geometry is approximately 2.4×10⁶ fibres per kilogram, or 2.2×10⁶ fibres per cubic metre at a dosage of 0.9 kg/m³. The polymer is hydrophobic and inert in the alkaline pore solution of concrete, but the as-supplied surface condition can influence wetting and fibre dispersion. The product is not a replacement for primary steel reinforcement, nor is it intended for structural macro-fibre applications where post-crack residual flexural strength is required. Its use lies between passive crack-width control and plastic-state micro-fibre reinforcement.
Fresh cementitious systems develop capillary tensile stress between solid particles as free pore water is removed by hydration and surface evaporation. According to ACI 305R-20, hot-weather concreting precautions become necessary when the evaporation rate exceeds 1.0 kg/m²/h. In this interval, the fresh paste retains little strain capacity, and a restrained volume change can initiate cracks at aggregate boundaries. A 12 mm polypropylene monofilament intersects these crack planes and redistributes the localised capillary stress over a larger paste volume. The crack either propagates around the filament, debonds the still-hydrating matrix, or strains the fibre in tension. At early ages the matrix-to-fibre bond is weak; therefore the primary contribution is physical interference and bridging of the plastic crack faces. Because the fibre is flexible and low-modulus relative to steel, it cannot restrain long-term drying shrinkage after the matrix has gained tensile strength. Its function is confined to the first 6 h to 24 h after placement, when the paste has not yet developed sufficient tensile stress resistance.
Evaluation under ASTM C1579-21 typically compares total crack area in a restrained slab containing fibres with that of a plain reference slab. For 12 mm micro-monofilaments at 0.9 kg/m³, published comparative data commonly show reductions in crack area between 40% and 80%, but the exact value depends on aggregate fineness modulus, cement fineness, plastic evaporation rate, and finishing procedures. Fibre addition does not remove the need for early curing or windbreaks. In a 0.40 w/c mix with cement content of 350 kg/m³, the available bleed water is low, and plastic shrinkage risk is high; the fibre acts as distributed crack bridging in the paste but cannot suppress cracks caused by inadequate cover or excessive vibration. Site-specific performance therefore cannot be predicted from fibre dosage alone.
In dry-charging operations, addition of hydrophobic fibres directly with aggregates and cement may create electrostatic clustering and visible fibre balls. In twin-shaft compulsory mixers with paddle tip speeds from 1.6 m/s to 2.0 m/s, the practical charging sequence is to load aggregates and approximately 50% of the total mixing water first, add cement, then introduce the fibre bags over the wetted aggregate surface. The remaining water and superplasticizer are added afterward. This sequence uses the initial water film to strip the fibre surface and to suspend the filaments before the paste begins to develop. For a 0.9 kg/m³ dosage in a 2 m³ pan mixer, steady addition over 30 s to 60 s is typically sufficient; high-shear pan mixers may achieve visual uniformity within 60 s to 90 s after the last bag is added. Truck-mixer drum rotation at mixing speed may require 5 min to 7 min to disperse the same dosage. If the addition rate exceeds the wetting capacity of the paste, visible agglomerates may form at the charging port or on mixer blades.
The measured slump loss at 0.9 kg/m³ is commonly 10 mm to 20 mm for a starting slump of 180 mm, depending on aggregate moisture and superplasticizer type. A mid-range or high-range water reducer conforming to ASTM C494/C494M-19 may be adjusted to compensate, but the dosage should be verified by trial batching. Fibre addition should be completed before 80% of the total mixing time has elapsed; extended mixing after full water addition can generate air voids at the hydrophobic fibre surface and reduce compressive strength. If visible fibre balls exceed 1 per 100 L of fresh concrete, the batching sequence, addition rate, or mixer speed is outside the practical dispersion window for this geometry.
Relative to fibrillated polypropylene fibres of the same length, the monofilament form has a lower specific surface area per unit mass and a circular cross-section that does not open into a network under shear. This reduces inter-fibre entanglement and improves handling in conveyor-based batching systems, but it also provides less post-crack friction than fibrillated or twisted fibres. In applications where dispersed fibre reinforcement is required solely for early-age crack width reduction, the lower surface area of the monofilament is acceptable. If the specification demands a measurable influence on hardened flexural toughness, the monofilament is the wrong fibre category; macro-synthetic or steel fibres should be evaluated under EN 14651:2005+A1:2007 or ASTM C1609/C1609M-19.
Steel fibres conforming to EN 14889-1:2006 and macro-synthetic fibres conforming to EN 14889-2:2006 Class II operate at lengths from 38 mm to 60 mm and diameters typically above 0.30 mm. Their dosages commonly range from 3.0 kg/m³ to 9.0 kg/m³ for macro-synthetic and 20 kg/m³ to 40 kg/m³ for steel, although steel dosage is project-specific. These fibres increase load-bearing capacity after cracking, measured as residual flexural tensile strength according to EN 14651:2005+A1:2007 or as load-deflection response under ASTM C1609/C1609M-19. SikaFiber Monofilament-12 at 0.9 kg/m³ does not generate equivalent residual strength because its aspect ratio is 54.5 based on a 12 mm length and 0.22 mm diameter, and the polymer modulus is on the order of 3.5 GPa to 4.0 GPa compared with 210 GPa for steel. The micro-fibre also cannot replace welded wire reinforcement for structural crack-width control in slabs-on-grade, because it does not provide the same post-yield tensile capacity. Its differentiation from steel is therefore fundamental: the product is electrochemically inert and will not corrode, but it contributes negligible long-term flexural capacity.
Compared with polyvinyl alcohol microfibres, polypropylene exhibits lower fibre-matrix bond strength and a lower elastic modulus in the 3.5 GPa to 4.0 GPa range, whereas PVA fibres are commonly reported in the 25 GPa to 40 GPa range. The hydrophobic surface of polypropylene reduces the strength of the interfacial transition zone unless mechanical anchorage is present. This difference means that PVA microfibres may show higher early-age crack suppression at equivalent or lower dosage, but they are more water-sensitive and may demand a more tightly controlled batching sequence. Published data for the exact PVA-to-SikaFiber Monofilament-12 comparison is limited.
The operational boundary of SikaFiber Monofilament-12 is defined by the absence of a controlled post-crack residual strength. In freeze-thaw environments, the product does not replace an air-entraining admixture; the hardened concrete must still meet the air-void requirements of ASTM C457/C457M-23 or equivalent regional specification. Similarly, it does not reduce the minimum required cover to steel reinforcement. No published data support its use as a structural crack-width agent in restrained walls or link slabs. In high-alkaline exposure, polypropylene is generally inert; however, published data for this specific product configuration under prolonged pH 13 exposure is limited. The fibre should be considered a controlled-dosage plastic-state reinforcement with a narrow performance window.
| Property | Declared value | Test basis |
|---|---|---|
| Nominal length | 12 mm | EN 14889-2:2006 dimensional method |
| Filament diameter | 0.22 mm | Supplier optical microscopy / declaration |
| Specific gravity | 0.91 g/cm³ | ISO 1183-1:2019 |
| Tensile strength | 300 MPa to 400 MPa | ISO 5079:2020 single-fibre tensile |
| Elastic modulus | 3.5 GPa to 4.0 GPa | Supplier literature |
| Melting range | 160 °C to 170 °C | ISO 11357-3:2018 |
| Calculated fibre count | 2.4×10⁶ per kilogram | Calculated from nominal geometry |
| Recommended dosage | 0.6 kg/m³ to 0.9 kg/m³ | Manufacturer batching range |
| Packaging | 0.9 kg dispersing bags | Manufacturer supply configuration |
| Standard / regulation | Application to SikaFiber Monofilament-12 |
|---|---|
| EN 14889-2:2006 | Polymer fibres for concrete; classification as Class I micro fibre |
| ASTM C1116/C1116M-10a | Type III synthetic fibre-reinforced concrete specification |
| ASTM C1579-21 | Plastic shrinkage cracking evaluation for restrained fibre-reinforced concrete |
| ACI 305R-20 | Hot-weather concreting; evaporation threshold of 1.0 kg/m²/h |
| ASTM C1609/C1609M-19 | Not applicable for post-crack performance at micro-fibre dosage; used for macro-fibre comparison |
| REACH Regulation (EC) No 1907/2006 | Polymer exemption under Article 2(9); compliance applies to monomer and supplier documentation |
| ISO 9001:2015 | Manufacturer quality management system documentation |