| HS Code | 874153 |
| Material | Polypropylene |
| Fiber Type | Monofilament |
| Color | White/Natural |
| Length | 12 mm |
| Diameter | 18 µm |
| Aspect Ratio | 667 |
| Density | 0.91 g/cm³ |
| Melting Point | 160 °C |
| Ignition Point | >360 °C |
| Tensile Strength | >300 MPa |
| Elastic Modulus | >3000 MPa |
| Alkali Resistance | Excellent |
| Water Absorption | Nil |
| Recommended Dosage | 0.6 - 1.2 kg/m³ |
| Packaging | 600 g bags, 20 bags per carton |
| Shelf Life | 24 months |
| Storage | Store dry, protected from moisture and direct sunlight |
As an accredited SikaFiber P/P 12 mm - Monofilament Polypropylene Fibers for Concrete and Mortars factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 0.6 kg water-soluble bags, packed 20 bags (12 kg) per carton for direct concrete/mortar addition. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): SikaFiber P/P 12 mm monofilament polypropylene fibers for concrete and mortars, palletized and secured for transport. |
| Shipping | SikaFiber P/P 12 mm is shipped as a non-hazardous construction material. It is supplied in sealed, moisture-resistant bags or cartons, palletized and shrink-wrapped for transport. Store in a dry, clean, ventilated area at ambient temperature, away from direct sunlight and sharp objects. No special dangerous-goods regulations apply. |
| Storage | Store SikaFiber P/P 12 mm in original, sealed bags in a dry, cool, well-ventilated area. Protect from moisture, direct sunlight, excessive heat, and ignition sources. Keep pallets off the ground and away from contaminants. Do not stack excessively high to prevent bag damage. Maintain good housekeeping; use FIFO rotation. Shelf life is typically 24 months when stored properly. |
| Shelf Life | 24 months from production date when stored in unopened original packaging, dry, and protected from direct sunlight. |
For ground-supported industrial floor slabs, SikaFiber P/P 12 mm is incorporated at 0.9 kg/m³ to 1.2 kg/m³ to control early-age plastic shrinkage cracking during the first 6–12 h after screeding. In ready-mix operations, the preferred introduction point is the aggregate conveyor stream at the batch plant, ahead of the mixer. Direct addition into the truck drum after water can result in monofilament balling when drum speed is below 14 rpm or when slump exceeds 150 mm. Central mixer or truck mixer high-speed mixing for a minimum of 5 min at 18–22 rpm is required to separate the bundled monofilaments and distribute them uniformly through the mix. The fibre is covered by EN 14889-2:2006 for CE marking; the hardened concrete falls under ASTM C1116/C1116M-10a Type III synthetic fibre-reinforced concrete when specified. Plastic shrinkage crack evaluation may be performed according to ASTM C1579-21, which provides a restrained slab cracking test method. The terminal elements include logistics apron slabs, warehouse floors, and internal machine foundation slabs where the acceptance criteria focus on early-age crack count reduction, not structural load capacity. Because the fibre does not replace structural steel, the slab bending capacity is governed by the same design standards as unreinforced concrete. Published data for this specific product configuration is limited in relation to increased joint spacing above 4.5 m without designer verification.
Field finishing of fibre-dosed slabs introduces a specific interaction with ride-on power trowels. At addition rates above 1.2 kg/m³, visible surface fuzz may appear if the trowel blade angle is kept flat after the final bleed-water sheen disappears. This is a production-scale observation, not a laboratory failure mode, and it is managed by sequencing trowel passes with steel blades only after surface moisture has cleared. The fibre does not interfere with saw-cut timing when cuts are made within 24 h of initial set.
Precast cable duct and roadside drainage units are demoulded after 16–24 h when the concrete compressive strength reaches 12–15 MPa; this is the period when corner and edge chipping is most common. The addition of SikaFiber P/P 12 mm at 0.6 kg/m³ to 1.0 kg/m³ reduces brittle edge fractures during demoulding and transport without altering the cover depth to steel reinforcement. In pan mixers or twin-shaft compulsory mixers, the fibre is dry-blended with sand and cement for 30 s before water is added, followed by a wet mixing cycle of 120 s. The dry-blend sequence is more important in precast than in ready-mix slab work because the lower water-to-cement ratio of 0.42–0.48 in precast mixes offers less free water for fibre dispersion. The moulds are filled on vibration tables at 40–60 Hz; over-vibration above 60 Hz can segregate the monofilament fibres toward upper corners. CE-marked precast elements are covered by EN 13369:2018 in combination with the relevant product standard, while the fibre itself carries EN 14889-2:2006. The fibre is not a substitute for lifting anchors or steel reinforcement in precast sections subject to high torsional handling loads. Terminal products include telecommunication cable ducts, roadside kerb drainage channels, and valve chambers where early-age edge integrity determines acceptance upon demoulding and unloading at the construction site.
In wet-mix shotcrete placement, SikaFiber P/P 12 mm is introduced at 1.0 kg/m³ to 2.0 kg/m³ into truck mixer concrete before transfer to a swing-tube concrete pump. The primary process constraint is not slump loss but pump pressure stability. At 2.0 kg/m³, monofilament fibres can increase pumping pressure by 5–10% in small-diameter delivery lines with 50 mm inner diameter and long horizontal runs above 60 m. Published data for this specific configuration is limited; mix-specific calibration at the nozzle before permanent lining application is required. Sprayed concrete is specified under EN 14487-1:2005 and material testing may follow ASTM C1436-13. The fibre contributes to plastic shrinkage crack reduction in temporary slope protection and initial tunnel linings but, because it is a microsynthetic fibre, it does not provide the post-crack residual flexural strength of steel or macrosynthetic fibres. Rebound reduction is frequently cited in technical literature, but the measured reduction varies with nozzle angle of 70–90° to the substrate, nozzle distance of 1.0–1.5 m, and accelerator dosage. A single rebound percentage is therefore not technically valid without referencing a specific mix. Terminal components include temporary excavation support linings, rock slope scaling barriers, and fire-protection linings where early-age plastic cracking control is the acceptance requirement.
When anhydrite or cement-based screeds are laid above underfloor heating circuits, the fibre is dry-mixed with the binder and sand before water is added at 0.6 kg/m³ to 0.9 kg/m³. This application is governed by EN 13813:2002 for screed materials and performance classifications. In continuous mixer-pump systems, the monofilament is metered into the dry mix through a vibratory feeder before the mixing chamber; adding it to the pump hopper after wetting causes fibre lumps that block 25 mm and 35 mm rotor-stator pump outlets. The terminal screed thickness over heating pipes is normally 35–45 mm for proprietary systems, but the fibre does not alter the minimum cover required by the pipe manufacturer. Early-age crack control in heated screed panels is addressed by the fibre at the plastic stage, not by thermal expansion resistance after commissioning. The hardened screed must still be commissioned under the heating system protocol with a gradual temperature rise rate, commonly 5°C/day. Bonded, unbonded, and floating screed configurations each accept the fibre, provided the mixing sequence is dry-blend first. Terminal products include residential underfloor heating bases, commercial floor toppings, and renovation screeds over old concrete slabs where edge curling and plastic cracking are primary failure modes.
| Application | Dosage | Primary standard | Process boundary |
|---|---|---|---|
| Ground-supported slab | 0.9–1.2 kg/m³ | EN 14889-2:2006 / ASTM C1116/C1116M-10a | Plant addition to aggregate stream |
| Precast cable ducts and pits | 0.6–1.0 kg/m³ | EN 13369:2018 | Dry blend before water |
| Wet-mix shotcrete | 1.0–2.0 kg/m³ | EN 14487-1:2005 | Pump pressure calibration |
| Screeds and underfloor heating bases | 0.6–0.9 kg/m³ | EN 13813:2002 | Vibratory feeder before pump |
| Marine splash-zone concrete | 0.9 kg/m³ | EN 206:2013+A2:2021 | No structural substitution |
| Precast retaining panels | 0.6–1.0 kg/m³ | EN 13369:2018 | Mixer addition before aggregate |
| Repair mortar | 0.5–0.9 kg/m³ | EN 1504-3:2005 | Dry blend before polymer dispersion |
Marine splash-zone concrete is specified under EN 206:2013+A2:2021 exposure class XS3, where chloride penetration and tidal wet-dry cycling govern durability. SikaFiber P/P 12 mm is added at 0.9 kg/m³ in such exposures for early-age crack reduction, not as a substitute for low water-to-binder ratio or supplementary cementitious materials. The fibre is mixed in the same plant addition sequence as slab concrete: aggregate stream, binder, fibre, then water and plasticizer. Field placement of mass concrete in marine works uses tremie pipes or pump booms; the fibre does not alter pumpability at this dosage. Hardened concrete testing includes chloride migration per EN 12390-18:2021 and compressive strength per EN 12390-3:2019. The operational boundary is explicit: polypropylene fibre does not prevent corrosion of embedded steel reinforcement in cracked marine concrete, and crack width limits under EN 1992-1-1 remain the governing design criterion. Published data for polypropylene fibre effect on salt scaling in this specific product configuration is limited. Terminal components include harbour wave walls, outfall structures, and quay wall capping beams where plastic shrinkage reduction during large-area casting is the sole fibre-related acceptance parameter.
During precast retaining wall panel handling, edge spalling is most commonly recorded when demoulding occurs at low early-age strength or when forklift forks bear directly on unprotected top edges. The fibre is dosed at 0.6 kg/m³ to 1.0 kg/m³ in self-compacting or stiff precast mixes, and it is added to the pan mixer before the coarse aggregate, not after plasticizer. In this sequence, the monofilament disperses through the mortar fraction and reduces edge breakage during stripping, rotation, and yard stacking. The precast elements are produced under EN 13369:2018 and the fibre under EN 14889-2:2006. Compressive strength acceptance at demoulding is typically 15 MPa for structural retaining units, measured by rebound hammer correlation or cube compression per EN 12390-3:2019. The fibre does not alter the structural reinforcement cage design in cantilever retaining walls, and lifting anchor capacity is governed by the anchor supplier and embedment depth. Terminal products include interlocking retaining wall blocks, gravity retaining panels, and acoustic barrier side panels where transport and installation damage are primary non-structural failure modes.
Repair mortar batching with 12 mm monofilament polypropylene fibre at 0.5 kg/m³ to 0.9 kg/m³ is executed in a forced-action mixer with a dry blending step of 60 s before water and polymer dispersion are introduced. The fibre must be dispersed before the polymer dispersion is added because polymer particles can agglomerate around undispersed fibre bundles, creating weak inclusions that lower pull-off strength. Repair mortars for structural concrete are specified under EN 1504-3:2005, with bond strength acceptance tested by EN 1542. At addition rates above 0.9 kg/m³, some patch mixes exhibit reduced flow in trowel-applied repairs, and the operative limit is verified by flow table spread of 180 ± 10 mm for Class R3 or R4 repair mortars. The fibre does not substitute for corrosion inhibitors in chloride-exposed patch repairs, nor does it replace the required surface preparation roughness or substrate saturation condition. Terminal components include hand-applied patch repairs on reinforced concrete beams, edge reconstitution of deteriorated columns, and low-shrinkage repair fills in car park slabs, where early-age plastic shrinkage cracking in the fresh patch is the main defect to be controlled.
Competitive SikaFiber P/P 12 mm - Monofilament Polypropylene Fibers for Concrete and Mortars prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Designated as a monofilament polypropylene fibre for cementitious matrices, SikaFiber P/P 12 mm is classified under EN 14889-2:2006 as a polymer fibre for concrete and mortars. The nominal cut length is 12 mm, and the manufacturer-declared filament diameter places the material in the Class I micro-fibre category because it remains below 0.30 mm. The product is intended for three-dimensional distribution in concrete, mortar, screed, and shotcrete at dosages that control early-age plastic shrinkage cracking, not for primary structural reinforcement. Published density for the polypropylene base polymer is approximately 0.91 g/cm³, measured in accordance with ISO 1183-1:2019. Because the fibre is polypropylene-based, it is resistant to cement alkalinity, chloride exposure, and moisture absorption; no corrosion mechanism exists as with steel reinforcement.
Plastic shrinkage cracking initiates when surface evaporation exceeds the bleeding rate of the fresh concrete. Capillary tension develops in the menisci of the setting paste, and the low tensile capacity of the plastic material is exceeded. The 12 mm monofilament acts by mechanically bridging microcracks during the period of maximum capillary pressure, increasing the energy required for crack propagation. The mechanism is physical rather than chemical: the fibre does not alter cement hydration kinetics, but it provides temporary crack-width control until the paste develops sufficient tensile strength. Evaporation risk can be evaluated using the nomograph in ACI 305R-20; when evaporation exceeds approximately 0.25 kg/m²/h, mitigation measures such as a micro-fibre addition become relevant. Performance may be pre-qualified using ASTM C1579-21, which evaluates restrained plastic shrinkage cracking under accelerated drying. Specifications may require a total crack-width reduction commonly in the range of 40–80 % for a fibre dosage of 0.9 kg/m³, though the exact acceptance limit is project-dependent and must be confirmed with the reference mix.
Compositionally, the fibre is an extruded polypropylene monofilament. The term monofilament differentiates the product from fibrillated polypropylene tape fibres: a monofilament is produced as a discrete filament, while a fibrillated product is manufactured from slitted and expanded film. This distinction affects dispersion behaviour in high-shear concrete mixers. Monofilament fibres generally exhibit lower entanglement than fibrillated products, but they still require controlled addition to prevent balling in low-paste concrete. The product does not function as a shrinkage-reducing admixture; it does not reduce the total drying shrinkage of hardened concrete, and it does not replace curing membranes, fogging, or windbreaks for plastic shrinkage control.
| Parameter | Value or classification | Standard or source |
|---|---|---|
| Fibre type | Monofilament polypropylene | EN 14889-2:2006 |
| Nominal length | 12 mm | Declaration of performance; mill certificate |
| Diameter classification | Class I micro-fibre, below 0.30 mm | EN 14889-2:2006 |
| Density | 0.91 g/cm³ | ISO 1183-1:2019 |
| Primary function | Plastic shrinkage crack control | ASTM C1579-21; EN 14889-2:2006 |
| Tensile strength and modulus | Declaration of performance values; typical producer range 300–400 N/mm² and 3.5–4.0 GPa | Producer test certificate |
Tensile strength and elastic modulus are not concrete design parameters for this product class, but they are used in fibre dispersion modelling and conformity assessment under EN 14889-2:2006. The cut-length tolerance is operationally significant: a shift from 12 mm to 15 mm changes the fibre aspect ratio and may reduce dispersion in low-slump concrete. Mill certificates should therefore be reviewed before batching. At a concrete plant, addition with the aggregate stream before water typically gives uniform distribution in pan and compulsory mixers. Direct addition of dry fibre into a stationary truck mixer after water can produce visible clumps at dosages above 0.6 kg/m³ if mixer speed is below 8 rpm or if batch temperature is below 10 °C. These are processing restrictions, not product defects. Static charge may cause monofilaments to adhere to weigh hopper walls in continuous mixing plants; if batch-to-batch fibre weight deviation exceeds 5 %, an anti-static bar or reduced fibre feed rate is generally required.
The regulatory and functional boundary is the equivalent diameter threshold in EN 14889-2:2006. Class I micro-fibres have an equivalent diameter below 0.30 mm; Class II macro-fibres exceed that threshold and may be used where post-crack residual strength is required. SikaFiber P/P 12 mm is a Class I micro-fibre. It should not be specified as the sole reinforcement system when structural post-crack performance is required under EN 14651 or ASTM C1609/C1609M, because the short length and low modulus do not generate measurable residual flexural strength at service-relevant crack widths. Steel fibres conforming to EN 14889-1:2006 or ASTM A820/A820M provide that capacity, but introduce density near 7.85 g/cm³, pumpability constraints, and finishing complications.
| Attribute | SikaFiber P/P 12 mm | Class II macro-synthetic fibre | Steel fibre |
|---|---|---|---|
| Standard class | EN 14889-2:2006 Class I | EN 14889-2:2006 Class II | EN 14889-1:2006 / ASTM A820/A820M |
| Length | 12 mm | 30–65 mm typical | 35–60 mm typical |
| Diameter or equivalent diameter | Below 0.30 mm | Above 0.30 mm | 0.5–1.0 mm |
| Density | 0.91 g/cm³ | 0.91–0.95 g/cm³ | 7.85 g/cm³ |
| Primary function | Plastic shrinkage crack reduction | Post-crack residual strength | Post-crack structural capacity |
| Corrosion risk | None | None | Possible without adequate cover |
| Effect on hardened tensile strength | Negligible at conventional dosage | Limited but measurable post-crack contribution | Significant post-crack contribution |
At equal mass dosage, steel fibres require greater mixer energy because of their density and can segregate in very low-slump concrete. Monofilament polypropylene fibres have a density close to that of paste and do not segregate under normal mixing. However, in excessively wet concrete with high bleed water, micro-fibres can migrate toward the surface. Compared with fibrillated polypropylene micro-fibres, the monofilament geometry presents a lower specific surface area at the same dosage, which can reduce the water demand penalty but may shift the minimum effective dosage for crack control. Published comparative data for identical paste volume indicate that monofilament polypropylene at 0.9 kg/m³ can achieve crack-width reduction comparable to fibrillated polypropylene at the same dosage, but the result is sensitive to aggregate grading, surface vapour flux, and placement thickness.
Dosing in the range of 0.9–1.2 kg/m³ is common for high-surface-area sections such as slab-on-grade, topping slabs, and repair mortars. At these addition levels, water demand may increase by 2–5 kg/m³ in concretes with total cementitious content below 300 kg/m³. The effect is usually less pronounced in paste-rich self-compacting mixtures. No universal correction factor exists because the slump result measured by EN 12350-2:2019 depends on aggregate angularity, free water, and superplasticizer dosage. In pumpable concrete with a target slump of 180 ± 20 mm, adding 0.9 kg/m³ of 12 mm monofilament may reduce slump by 10–25 mm, but the exact value must be established in a plant trial using the site aggregate stock.
Finishability is affected by surface exposure of the monofilament. Early power floating can raise fibres to the surface if the paste has not developed sufficient stiffness. Overworking the surface may expose individual filaments, and visible fibre haze is best controlled by avoiding premature finishing, not by increasing water. In repair mortars conforming to EN 1504-3, the fibre provides early-age crack control only; it does not replace crack-bridging properties or structural mesh required by the repair specification. Overdosing above 1.8 kg/m³ is generally unnecessary for plastic shrinkage control and may produce fibre balling, non-uniform surface texture, and reduced pumpability through 50 mm steel lines. Fibre clumps can obstruct 90° pump elbows if the aggregate skeleton is gap-graded and paste volume is below 280 L/m³. Published data for this specific configuration is limited, and pump trials under actual job-site geometry remain required.
Because the polypropylene monofilament is hydrophobic and disperses without absorbing water, it has been used in dry-mix and wet-mix shotcrete at dosages up to 1.0 kg/m³ to reduce plastic shrinkage in thick linings. In fire-exposure applications, polypropylene micro-fibres melt at approximately 160–170 °C, determined by differential scanning calorimetry according to ISO 11357-3:2018. The melting process creates connected void channels that can reduce pore-pressure spalling, but that mechanism is time- and dosage-dependent and must be validated by fire testing under a specified heating curve such as ISO 834-1 or EN 1363-1. The 12 mm monofilament grade is not a fire-protection product on its own; its contribution to spalling resistance is relevant only when the concrete mix design includes the required permeability and moisture condition.
For quality assurance, the declaration of performance should be checked against EN 14889-2:2006 for fibre geometry, density, tensile strength, and chloride content. CE marking under Regulation (EU) No 305/2011 requires the manufacturer to issue a declaration of performance for the harmonised characteristic. A mill certificate typically records nominal length and tolerance band; any batch outside ±10 % of the specified length should be isolated because aspect ratio changes can alter dispersion and plastic-shrinkage crack reduction. Storage requires protection from direct ultraviolet exposure and high humidity. Polypropylene itself does not absorb water, but wet packaging can lead to clumping at the batching conveyor. In continuous mixing plants with high-shear pan mixers, the fibre should be added to the dry aggregate stream rather than the cement weigh hopper to reduce static adhesion and dosing error. The product is not classified as a hazardous substance under the relevant safety data sheet, but standard dust-control measures apply when handling bulk fibre bags.